Fig. 1

Benchmark Biometric Sensor System for Hearable Devices

  • Sensor VLED: 3.1 to 5.5 VDC (Red + IR LED Only)
  • V DD MCU current: 255 µ A standard operation
  • Chest-strap quality optical heart rate (HR)
  • V LED Sensor current: 0.11 mA standard operation

measurement, step rate / count, distance, cycling

  • Field updatable processor firmware

cadence, calories, R-R interval (RRi) and activity

  • The Benchmark ® sensor and PerformTek ® processor

The PerformTek powered Benchmark Ear 5.0 (BE5.0)

minimize space impact to the hearable design and

Sensor System is the smallest biometric sensor

technology developed by Valencell, Inc. to date. The

  • Sensor module contains an LED and optical detector

modular design brings together the best available parts

with data conversion circuitry mounted to a lens

of a successful biometric sensor system in a smaller

assembly optimized for sensor system accuracy

form factor and includes emitter/detector sensor

  • PerformTek low-power ARM ® Cortex ® processor

electronics in an optimized optical package with a

performs sensor data processing and provides a

processor that is pre-programmed with Valencell’s

communication interface to the system Host

PerformTek advanced biometric algorithms.

Figure 1BE5.0 PerformTek MCU and Sensor
Figure 2BE5.0 Simplified Block Diagram
Benchmark Biometric Sensor System diagram (page 1)
Fig. 2
  • Sensor Dimensions: 14-pin, 0.6 mm pitch,

(5.80 x 3.90 x 3.40) mm

  • IMU Dimensions: LGA-12, 0.5 mm pitch,

(2.00 x 2.00 x 0.93) mm

  • MCU Dimensions: CSP-49, 0.35 mm pitch,

(2.56 x 2.59 x 0.45) mm

  • In-canal or in-concha wired or wireless headphones
  • 400 kHz I2C or 57.6 kbps UART interface
  • Hearing aids
  • Processor and IMU VDD: 1.8 VDC to 3.3 VDC
  • Mono Bluetooth headsets
  • Sensor VLED: 2.8 to 5.5 VDC (IR LED Only)
  • Wireless smart audio assistants
Revision04.00 Copyright © 2020 by Valencell, Inc. Page 1 / 20 Patents: www.valencell.com/patents
Show 6 more labels / short text on this page
Features · recognition (running/lifestyle) · Description · provide design flexibility · processor · Applications
Page 2 of the Benchmark Biometric Sensor System user manual — Change Record
Page 2 · click to enlarge
Page 2

Reference Documentation

Table 1Related Documents
DocumentTitle 001917PerformTek Low Power MCU Integration Guide 000638PerformTek Interface Protocol Document 000964PerformTek User Guide 002335PerformTek Low Power Motion Detect Addendum 000532Benchmark Ear Integration Guide 001926BE 5.0 Sensor Window Drawing 001913BE 5.0 Sensor Drawing 001912BE 5.0 Sensor 3D CAD Model
Benchmark Biometric Sensor System — Reference Documentation diagram (page 2)
Fig. 3 · Reference Documentation

Change Record

Table 2Change Record
AuthorRevisionDateDescription of change(s) MEP01.0002MAY2019Initial Release of Preliminary BE5.0 Datasheet MEP01.0102AUG2019Update based on design finalization. Removed Preliminary marking Removed PerformTek MCU information and added reference to the PerformTek Low Power MCU Integration Guide SWC01.0202DEC2019Fixed typo on page 16 Corrected the number of components listed in section 9 (from 2 to 3) SWC02.0023DEC2019Updated sensor dimensions and drawing MEP03.0031MAR2020Added power information for red LED MEP04.0015OCT2020Updates based on Official firmware release, version 1742 Updated section 3: - Added information for Sleep mode - Updated current consumption - Corrected minimum storage temperature - Increased recommended minimum VLED operating voltage for IR LED to provide additional noise immunity and support for future features
Revision04.00 Copyright © 2020 by Valencell, Inc. Page 2 / 20 Patents: www.valencell.com/patents
Page 4 of the Benchmark Biometric Sensor System user manual — Block Diagram / System Overview
Page 4 · click to enlarge
Page 4

Block Diagram / System Overview

The Benchmark Ear 5.0 Biometric Sensor solution is provided in three pieces, a sensor, an accelerometer,

and a Low Power PerformTek processor. Figure 3 shows how these pieces work together and is

described below.

Benchmark Biometric Sensor System — Block Diagram / System Overview diagram (page 4)
Fig. 4 · Block Diagram / System Overview
Figure 3Benchmark Ear 5.0 Functional Block Diagram

On the left of the diagram, the sensor module circuit board contains a digital optical detector system with

infrared and red LEDs. The detector and LEDs work together with the accelerometer to collect biometric

information via reflected light and movement from the wearer. This information is transmitted over an I2C

bus when requested by the PerformTek processor.

The PerformTek processor collects the sensor data and runs Valencell’s patent protected algorithms to

convert the raw measurements into biometric values such as heart rate or cadence and processes those

values further into higher level user assessments like calories burned. In addition, sensor module

diagnostics such as signal quality and error codes are available. This information is available to the Host

processor via the Host interface.

Revision04.00 Copyright © 2020 by Valencell, Inc. Page 4 / 20 Patents: www.valencell.com/patents
Page 5 of the Benchmark Biometric Sensor System user manual — 1 Block Diagram / System Overview
Page 5 · click to enlarge
Page 5

The Host interface is shown on the right side of the diagram. Control lines for interfacing the Host

processor with the PerformTek processor include an I2C or UART, power-on self-test / sensor interrupt

output (POST / PTEK_INT_N), and sensor interrupt / bootloader mode select input (HOST_INT_N /

BOOT_OVERRIDE_N). For I2C serial communications with the Host processor, the PerformTek processor

acts as the I2C slave role and the Host processor acts as the I2C Master. More details on this interface

are provided in the PerformTek Low Power MCU Integration Guide.

Revision04.00 Copyright © 2020 by Valencell, Inc. Page 5 / 20 Patents: www.valencell.com/patents
Page 6 of the Benchmark Biometric Sensor System user manual — Sensor Pin Description
Page 6 · click to enlarge
Page 6

Sensor Pin Description

Table 3 shows the pin definitions for the sensor. See Section 7 for the physical pinout and package dimensions of the sensor,

Table 3Sensor Pinout
Pin NumberSymbolDescription 1SDAI2C Data Line. Connect to accelerometer and PerformTek Processor 2SCLI2C Clock Line. Connect to accelerometer and PerformTek Processor 3LDO_ENConnect to VLED 4LDOInternal LDO. Connect 1μF capacitor to GND_A 5VLEDSensor power: Connect VLED power to this pin via a zero Ohm resistor. Option A: Add a 0.1μF ceramic capacitor and a 47uF polymer tantalum to this pin and GND_L / GND (recommended to reduce risk of audible noise due to piezoelectric effect and to provide path for future design changes that may limit peak current demand from the sensor) Option B: Add a 0.1μF ceramic capacitor and a 10uF ceramic capacitor to this pin and GND_L / GND (minimum requirement) 6NCNo Connect 7NCNo Connect 8NCNo Connect 9GND_LConnect to GND 10GND_DTie to GND_A and connect to GND 11GND_ATie to GND_D and connect to GND 12VREFInternal reference for sensor. Connect 1µF capacitor between this pin and GND / GND_A 13NCNo Connect 14NCNo Connect
Revision04.00 Copyright © 2020 by Valencell, Inc. Page 6 / 20 Patents: www.valencell.com/patents
Page 7 of the Benchmark Biometric Sensor System user manual — Electrical Characteristics
Page 7 · click to enlarge
Page 7

Electrical Characteristics

The recommended operating conditions of the BE5.0 Sensor are shown in Table 4. See the PerformTek

Low Power MCU Integration Guide for information on the PerformTek MCU.

Table 4Recommended Operating Conditions for Sensor
ParameterSymbolConditionsMinTypMaxUnits Sensor LED Supply Voltage (IR and Red LED Operation)1V LED(Red)Min and Max are inclusive of V ripple requirement DD3.13.35.5VDC Sensor LED Supply Voltage (IR LED Operation Only)V LED(IR)Min and Max are inclusive of V ripple requirement DD3.0 (2.8) 43.35.5VDC Sensor ripple voltage_10V ripple_10Sensor system active: 0 to 10 MHz Ripple--50mV pp Sensor ripple voltage_100V ripple_100Sensor system active: >10 MHz to 100 MHz Ripple--100mV pp Operating Temperature-Device operating in Standby, Idle, or Active Modes-102550oC
Benchmark Biometric Sensor System — Electrical Characteristics diagram (page 7)
Fig. 5 · Electrical Characteristics

The operating characteristics of the BE5.0 Sensor are shown in Table 4. See the PerformTek Low Power

MCU Integration Guide for information on the PerformTek MCU. For total PerformTek MCU plus sensor

power, the current for the sensor shown in this table, should be combined with the information from the

PerformTek Low Power MCU Integration Guide.

Revision04.00 Copyright © 2020 by Valencell, Inc. Page 7 / 20 Patents: www.valencell.com/patents
Page 8 of the Benchmark Biometric Sensor System user manual — 3 Electrical Characteristics
Page 8 · click to enlarge
Page 8
Table 5Operating Characteristics of Sensor
ParameterSymbolConditionsMin Typ MaxUnits Sensor Current OFF Mode-No V supply given to sensor module DD0µA Sensor Current Sleep5 and Idle Modes-System is in Standby mode1.6µA VLED Current Active Mode, Standard-Precision RRi, IR LED Only1 6-HR measurement with Standard-precision RRi sampling rate, IR LED only VLED = 3.3 VDC0.05 to 0.11mA Sensor Current Active Mode, Standard-Precision RRi, IR + Red1 6-HR measurement with Standard-precision RRi sampling rate, IR and Red LEDs only VLED = 3.3 VDC0.09 to 0.20mA Sensor Current Active Mode, HighPrecision RRi1 6-HR measurement with High-precision RRi sampling rate, IR LED only VLED = 3.3 VDC0.23 to 0.55mA Sensor Current Active Mode, Blood Pressure 1 3 6-BP measurement, IR LED only VLED = 3.3 VDC0.09 to 0.22mA Sensor Pulse Current2I pulseSystem is in Active mode VLED = 3.3 VDC25mA
Benchmark Biometric Sensor System — 3 Electrical Characteristics diagram (page 8)
Fig. 6 · 3 Electrical Characteristics

approximately 0.27mA @ 1.8 VDC or 0.26mA @3.3VDC with buck supplies enabled. Contact Valencell for more details.

improve power supply noise immunity and ensure compatibility with future features. Contact Valencell if there are any questions or if sensor

must support 2.8 VDC operation.

value shown in this range; however, the Optical Trim Feature may reduce this current in some cases. See the PerformTek User Guide for more

details on this feature.

Revision04.00 Copyright © 2020 by Valencell, Inc. Page 8 / 20 Patents: www.valencell.com/patents
Page 9 of the Benchmark Biometric Sensor System user manual — 3 Electrical Characteristics
Page 9 · click to enlarge
Page 9

Absolute limits are provided in Table 6. If these limits are exceeded, permanent device damage may occur.

Additionally, if the sensor is exposed to these limits for an extended period, the sensor reliability may be

impacted.

Table 6Sensor Absolute Maximum Limits
ParameterSymbolConditionsMinTypMaxUnits Operating Temperature-Device operating in Standby, Idle, or Active Modes – performance not guaranteed-10-50oC Storage Temperature-Device powered off; device will require time to come to equalize with normal operating temperature after exposure to limits of storage temperature-40-85oC
Revision04.00 Copyright © 2020 by Valencell, Inc. Page 9 / 20 Patents: www.valencell.com/patents
Page 10 of the Benchmark Biometric Sensor System user manual — Sensor Electrical Integration
Page 10 · click to enlarge
Page 10

Sensor Electrical Integration

The BE5.0 sensor (U1) is designed to work with the included Low Power PerformTek MCU processor and

accelerometer (U2). Connections for this sensor along with the accelerometer are shown in Figure 4. The

Low Power PerformTek MCU is not shown in this schematic but should be powered by the same (or

equivalent) VDD supply that is shown connected to the accelerometer and should be connected to the

nets identified by the orange rectangle.

Figure 4BE5.0 Sensor Schematic
Benchmark Biometric Sensor System — Sensor Electrical Integration diagram (page 10)
Fig. 7 · Sensor Electrical Integration
Revision04.00 Copyright © 2020 by Valencell, Inc. Page 10 / 20 Patents: www.valencell.com/patents
Page 11 of the Benchmark Biometric Sensor System user manual — PerformTek Processor
Page 11 · click to enlarge
Page 11

PerformTek Processor

The included PerformTek Low Power MCU is implemented on an Ambiq Micro Apollo2 processor. This processor

provides significant power savings from Ambiq’s patented Subthreshold Power Optimized Technology (SPOT).

This is an ARM Cortex-M4 based processor and is provided in a 49-pin Chip Scale Package (CSP).

The processor is programmed by Valencell, Inc. with PerformTek custom firmware and algorithms. See the

PerformTek Low Power MCU Integration Guide for interface requirements and integration guidelines.

Revision04.00 Copyright © 2020 by Valencell, Inc. Page 11 / 20 Patents: www.valencell.com/patents
Page 12 of the Benchmark Biometric Sensor System user manual — 6.3 Audio Quality Design Guidelines
Page 12 · click to enlarge
Page 12

Additional Electrical Design Guidelines

6.1 Power Supply Loading

The system power supply or supplies should be designed to meet the requirements in Section 3 with

loading and transients from both the Benchmark sensor, accelerometer, and the PerformTek MCU.

Peak VLED current will be periodic where the period of the peaks will depend on the mode of operation,

Heart Rate and Standard-Precision RRi (40 ms) and High-Precision RRi (8 ms). The peak current identified

in Section 3 are based on both measured and specified system performance. Processor VDD current

peaks are of smaller amplitude and much smaller duration than VLED current peaks. Actual peak and

average VDD processor current peak and average numbers will vary depending on the unique

characteristics of the system design and how the PerformTek features are used within the system.

Because of this, Valencell recommends testing our sensors in a manner representative of their intended

use as early as possible in the design cycle. To facilitate this, Valencell supplies development kits that

support early prototyping and power measurement and can provide design support and review services

upon request.

6.2 Mixed Voltage Operation and Power Supply Separation

The accelerometer and the Low Power PerformTek MCU should be supplied by the same voltage rail

(VDD). Generally, the BE5.0 sensor VLED should be supplied by a different power rail than VDD since it

allows separation that may be helpful in meeting the ripple requirements of the sensor and it may be

desirable to operate the PerformTek MCU and accelerometer at a lower voltage than VLED. In cases

where it is desirable to do so, the VDD and VLED rails may be combined if all requirements specified in

Section 3 are still met.

6.3 Audio Quality Design Guidelines

While the Benchmark sensor does not generate any perceptible audible noise on its own, it is possible for

system power supply noise or crosstalk from the sensor I2C lines to interfere with audio quality if

appropriate system design considerations are not followed. To mitigate potential noise issues, design

considerations should include:

- Good power and ground plane design and decoupling to minimize conducted system noise into

sensor and / or audio cabling

- Appropriate audio circuit and system grounding to ensure any coupled noise is either returned to

the system reference as appropriate or blocked by appropriate isolation

Revision04.00 Copyright © 2020 by Valencell, Inc. Page 12 / 20 Patents: www.valencell.com/patents
Page 13 of the Benchmark Biometric Sensor System user manual — 6 Additional Electrical Design Guidelines
Page 13 · click to enlarge
Page 13

- Isolation of audio circuitry signals from sensor I2C, power, and ground lines to minimize crosstalk

(This may be accomplished by a combination of PCB routing and or cable design as appropriate)

- Minimize ceramic capacitors exposed to large current transients in locations that could couple

audible noise into the ear

Revision04.00 Copyright © 2020 by Valencell, Inc. Page 13 / 20 Patents: www.valencell.com/patents
Page 14 of the Benchmark Biometric Sensor System user manual — Sensor Physical Integration
Page 14 · click to enlarge
Page 14

Sensor Physical Integration

The BE5.0 sensor is shown in Figure 5. Placement and proper integration of the sensor into the hearable

system housing is critical for accurate measurement. For enclosure capture feature design and adhesive

process guidelines and more complete details on sensor integration, refer to the Benchmark Ear

Integration Guide.

The sensor electrical interface geometry is shown in Figure 6. For best performance, the below layout

recommendations should be followed

  • All bypass capacitors should be placed as close to the part as possible.
  • All no connect pins should be soldered down
  • All ground pins should be connected to a ground plane
  • Avoid sharing vias for decoupling capacitor connections
  • Minimize the impedance of power and ground connections
Figure 5BE5.0 Sensor Images
Benchmark Biometric Sensor System — Sensor Physical Integration diagram (page 14)
Fig. 8 · Sensor Physical Integration
Revision04.00 Copyright © 2020 by Valencell, Inc. Page 14 / 20 Patents: www.valencell.com/patents
Page 15 of the Benchmark Biometric Sensor System user manual — 7 Sensor Physical Integration
Page 15 · click to enlarge
Page 15
Figure 6BE5.0 Sensor Drawing and Solder Pads
Benchmark Biometric Sensor System — 7 Sensor Physical Integration diagram (page 15)
Fig. 9 · 7 Sensor Physical Integration
Benchmark Biometric Sensor System — 7 Sensor Physical Integration diagram (page 15)
Fig. 10 · 7 Sensor Physical Integration
Revision04.00 Copyright © 2020 by Valencell, Inc. Page 15 / 20 Patents: www.valencell.com/patents
Page 16 of the Benchmark Biometric Sensor System user manual — Accelerometer Physical Integration
Page 16 · click to enlarge
Page 16

Accelerometer Physical Integration

The accelerometer package and electrical interface geometry is shown in Figure 7. See the Benchmark

Ear Integration Guide for additional placement and proper integration guidelines.

Figure 7BE5.0 Accelerometer Drawing and Solder Pads
Benchmark Biometric Sensor System — Accelerometer Physical Integration diagram (page 16)
Fig. 11 · Accelerometer Physical Integration
Revision04.00 Copyright © 2020 by Valencell, Inc. Page 16 / 20 Patents: www.valencell.com/patents
Page 17 of the Benchmark Biometric Sensor System user manual — 3. BE5.0-AMAPH1KK-KCR
Page 17 · click to enlarge
Page 17

Benchmark Sensor Ordering Guide

001931 Benchmark Ear 5.0

001931 Benchmark Ear 5.0 consists of a set of three components

BE5.0-Set

1. BE5.0-Sensor
2. BE5.0-Accelerometer

3. BE5.0-AMAPH1KK-KCR

Revision04.00 Copyright © 2020 by Valencell, Inc. Page 17 / 20 Patents: www.valencell.com/patents

Part Number Description

Page 18 of the Benchmark Biometric Sensor System user manual — Valencell Product Development Design and Test Services
Page 18 · click to enlarge
Page 18

Valencell Product Development Design and Test Services

Valencell has years of experience helping customers bring accurate biometric hearable and wearable

devices to market. Much of our experience has been captured in application notes and in the integration

and user guides, but additional design and test support is available upon request to help reduce your time

to market and lower your technical development risks. Our support can span all stages of the product

development process, from concept development through mass production and marketing. Design

support examples include assisting with placement and mechanical integration of the sensor module

within the product being worn; product fit and comfort; power-supply design; and audio design

considerations for hearable designs.

Additionally, product performance should be backed by a solid test plan. Valencell has a sophisticated

exercise and sport physiology test lab where products using our sensors are tested for proper

performance. Our biometric sensors have been tested on thousands of test subjects with the statistical

analysis done in a way that conforms to medical and sports journal publication standards. Testing is

carried out both indoors and outdoors under many different activities with pools of subjects that have

different skin tones, weight, hair, and fitness levels. Results from our sensor tests can be seen in the form

of technical white papers on the Valencell website here: www.valencell.com/white-papers Valencell Labs

is located in the U.S. where there is a good diversity of test subjects. Our lab can validate the accuracy

and performance of your product design and provide a statistical analysis as part of a design feedback

report along with suggestions to improve the product design. This type of testing is the best and only way

to know how well your product will perform when introduced into the market.

For more information about our support options, please contact Valencell.

Revision04.00 Copyright © 2020 by Valencell, Inc. Page 18 / 20 Patents: www.valencell.com/patents
Page 19 of the Benchmark Biometric Sensor System user manual — Contact Information
Page 19 · click to enlarge
Page 19

Contact Information

For additional information please contact:

Sales Supportbenchmark@ valencell.com
Technical Supportsupport@ valencell.com

Valencell, Inc.

4601 Six Forks Rd. Suite 103

www.valencell.com

Revision04.00 Copyright © 2020 by Valencell, Inc. Page 19 / 20 Patents: www.valencell.com/patents

Raleigh, NC 27609

Page 20 of the Benchmark Biometric Sensor System user manual — MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
Page 20 · click to enlarge
Page 20

Statements

Valencell reserves the right to make changes to its products or example designs as

part of its development program. This document and any other related support

materials (collectively, the “Materials”) are intended to serve as resources only and

users should not rely on them to ensure compliance with any laws or requirements.

Benchmark™ and PerformTek™ technology are not designed or authorized for use in

life support, medical, or safety critical applications.

THE MATERIALS ARE PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,

EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF

MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND

NONINFRINGEMENT. IN NO EVENT SHALL VALENCELL, INC., BE LIABLE FOR ANY

CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT,

TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE

MATERIALS.

No license is granted or implied under any patent or other rights owned by Valencell,

Inc., by the publication or transfer of the information contained herein. Unless

otherwise stated, words and logos marked with ® or ™ are trademarks registered or

owned by Valencell, Inc. Other products, services and names used in this document

may have been trademarked by their respective owners.

Patent Notice:

Protected by granted patents and/or patents pending: www.valencell.com/patents

Both Benchmark® and PerformTek® and the Benchmark and PerformTek designs are registered

trademarks of Valencell, Inc. and may not be used for any purpose without the express prior written

consent of Valencell, Inc.

Revision04.00 Copyright © 2020 by Valencell, Inc. Page 20 / 20 Patents: www.valencell.com/patents

Ask about the Benchmark Biometric Sensor System

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Benchmark Biometric Sensor System

Be the first to ask — other owners or our team will answer.

Original document

Benchmark Biometric Sensor System manual PDF

20 pages·532 KB·Sensor·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…