Benchmark Biometric Sensor System for Hearable Devices
measurement, step rate / count, distance, cycling
cadence, calories, R-R interval (RRi) and activity
The PerformTek powered Benchmark Ear 5.0 (BE5.0)
minimize space impact to the hearable design and
Sensor System is the smallest biometric sensor
technology developed by Valencell, Inc. to date. The
modular design brings together the best available parts
with data conversion circuitry mounted to a lens
of a successful biometric sensor system in a smaller
assembly optimized for sensor system accuracy
form factor and includes emitter/detector sensor
electronics in an optimized optical package with a
performs sensor data processing and provides a
processor that is pre-programmed with Valencell’s
communication interface to the system Host
PerformTek advanced biometric algorithms.

(5.80 x 3.90 x 3.40) mm
(2.00 x 2.00 x 0.93) mm
(2.56 x 2.59 x 0.45) mm




The Benchmark Ear 5.0 Biometric Sensor solution is provided in three pieces, a sensor, an accelerometer,
and a Low Power PerformTek processor. Figure 3 shows how these pieces work together and is
described below.

On the left of the diagram, the sensor module circuit board contains a digital optical detector system with
infrared and red LEDs. The detector and LEDs work together with the accelerometer to collect biometric
information via reflected light and movement from the wearer. This information is transmitted over an I2C
bus when requested by the PerformTek processor.
The PerformTek processor collects the sensor data and runs Valencell’s patent protected algorithms to
convert the raw measurements into biometric values such as heart rate or cadence and processes those
values further into higher level user assessments like calories burned. In addition, sensor module
diagnostics such as signal quality and error codes are available. This information is available to the Host
processor via the Host interface.

The Host interface is shown on the right side of the diagram. Control lines for interfacing the Host
processor with the PerformTek processor include an I2C or UART, power-on self-test / sensor interrupt
output (POST / PTEK_INT_N), and sensor interrupt / bootloader mode select input (HOST_INT_N /
BOOT_OVERRIDE_N). For I2C serial communications with the Host processor, the PerformTek processor
acts as the I2C slave role and the Host processor acts as the I2C Master. More details on this interface
are provided in the PerformTek Low Power MCU Integration Guide.

Table 3 shows the pin definitions for the sensor. See Section 7 for the physical pinout and package dimensions of the sensor,

The recommended operating conditions of the BE5.0 Sensor are shown in Table 4. See the PerformTek
Low Power MCU Integration Guide for information on the PerformTek MCU.

The operating characteristics of the BE5.0 Sensor are shown in Table 4. See the PerformTek Low Power
MCU Integration Guide for information on the PerformTek MCU. For total PerformTek MCU plus sensor
power, the current for the sensor shown in this table, should be combined with the information from the
PerformTek Low Power MCU Integration Guide.


approximately 0.27mA @ 1.8 VDC or 0.26mA @3.3VDC with buck supplies enabled. Contact Valencell for more details.
improve power supply noise immunity and ensure compatibility with future features. Contact Valencell if there are any questions or if sensor
must support 2.8 VDC operation.
value shown in this range; however, the Optical Trim Feature may reduce this current in some cases. See the PerformTek User Guide for more
details on this feature.

Absolute limits are provided in Table 6. If these limits are exceeded, permanent device damage may occur.
Additionally, if the sensor is exposed to these limits for an extended period, the sensor reliability may be
impacted.

The BE5.0 sensor (U1) is designed to work with the included Low Power PerformTek MCU processor and
accelerometer (U2). Connections for this sensor along with the accelerometer are shown in Figure 4. The
Low Power PerformTek MCU is not shown in this schematic but should be powered by the same (or
equivalent) VDD supply that is shown connected to the accelerometer and should be connected to the
nets identified by the orange rectangle.


The included PerformTek Low Power MCU is implemented on an Ambiq Micro Apollo2 processor. This processor
provides significant power savings from Ambiq’s patented Subthreshold Power Optimized Technology (SPOT).
This is an ARM Cortex-M4 based processor and is provided in a 49-pin Chip Scale Package (CSP).
The processor is programmed by Valencell, Inc. with PerformTek custom firmware and algorithms. See the
PerformTek Low Power MCU Integration Guide for interface requirements and integration guidelines.

The system power supply or supplies should be designed to meet the requirements in Section 3 with
loading and transients from both the Benchmark sensor, accelerometer, and the PerformTek MCU.
Peak VLED current will be periodic where the period of the peaks will depend on the mode of operation,
Heart Rate and Standard-Precision RRi (40 ms) and High-Precision RRi (8 ms). The peak current identified
in Section 3 are based on both measured and specified system performance. Processor VDD current
peaks are of smaller amplitude and much smaller duration than VLED current peaks. Actual peak and
average VDD processor current peak and average numbers will vary depending on the unique
characteristics of the system design and how the PerformTek features are used within the system.
Because of this, Valencell recommends testing our sensors in a manner representative of their intended
use as early as possible in the design cycle. To facilitate this, Valencell supplies development kits that
support early prototyping and power measurement and can provide design support and review services
upon request.
The accelerometer and the Low Power PerformTek MCU should be supplied by the same voltage rail
(VDD). Generally, the BE5.0 sensor VLED should be supplied by a different power rail than VDD since it
allows separation that may be helpful in meeting the ripple requirements of the sensor and it may be
desirable to operate the PerformTek MCU and accelerometer at a lower voltage than VLED. In cases
where it is desirable to do so, the VDD and VLED rails may be combined if all requirements specified in
Section 3 are still met.
While the Benchmark sensor does not generate any perceptible audible noise on its own, it is possible for
system power supply noise or crosstalk from the sensor I2C lines to interfere with audio quality if
appropriate system design considerations are not followed. To mitigate potential noise issues, design
considerations should include:
- Good power and ground plane design and decoupling to minimize conducted system noise into
sensor and / or audio cabling
- Appropriate audio circuit and system grounding to ensure any coupled noise is either returned to
the system reference as appropriate or blocked by appropriate isolation

- Isolation of audio circuitry signals from sensor I2C, power, and ground lines to minimize crosstalk
(This may be accomplished by a combination of PCB routing and or cable design as appropriate)
- Minimize ceramic capacitors exposed to large current transients in locations that could couple
audible noise into the ear

The BE5.0 sensor is shown in Figure 5. Placement and proper integration of the sensor into the hearable
system housing is critical for accurate measurement. For enclosure capture feature design and adhesive
process guidelines and more complete details on sensor integration, refer to the Benchmark Ear
Integration Guide.
The sensor electrical interface geometry is shown in Figure 6. For best performance, the below layout
recommendations should be followed





The accelerometer package and electrical interface geometry is shown in Figure 7. See the Benchmark
Ear Integration Guide for additional placement and proper integration guidelines.


001931 Benchmark Ear 5.0
001931 Benchmark Ear 5.0 consists of a set of three components
BE5.0-Set
Part Number Description

Valencell has years of experience helping customers bring accurate biometric hearable and wearable
devices to market. Much of our experience has been captured in application notes and in the integration
and user guides, but additional design and test support is available upon request to help reduce your time
to market and lower your technical development risks. Our support can span all stages of the product
development process, from concept development through mass production and marketing. Design
support examples include assisting with placement and mechanical integration of the sensor module
within the product being worn; product fit and comfort; power-supply design; and audio design
considerations for hearable designs.
Additionally, product performance should be backed by a solid test plan. Valencell has a sophisticated
exercise and sport physiology test lab where products using our sensors are tested for proper
performance. Our biometric sensors have been tested on thousands of test subjects with the statistical
analysis done in a way that conforms to medical and sports journal publication standards. Testing is
carried out both indoors and outdoors under many different activities with pools of subjects that have
different skin tones, weight, hair, and fitness levels. Results from our sensor tests can be seen in the form
of technical white papers on the Valencell website here: www.valencell.com/white-papers Valencell Labs
is located in the U.S. where there is a good diversity of test subjects. Our lab can validate the accuracy
and performance of your product design and provide a statistical analysis as part of a design feedback
report along with suggestions to improve the product design. This type of testing is the best and only way
to know how well your product will perform when introduced into the market.
For more information about our support options, please contact Valencell.

For additional information please contact:
Valencell, Inc.
4601 Six Forks Rd. Suite 103
Raleigh, NC 27609

Valencell reserves the right to make changes to its products or example designs as
part of its development program. This document and any other related support
materials (collectively, the “Materials”) are intended to serve as resources only and
users should not rely on them to ensure compliance with any laws or requirements.
Benchmark™ and PerformTek™ technology are not designed or authorized for use in
life support, medical, or safety critical applications.
THE MATERIALS ARE PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF
NONINFRINGEMENT. IN NO EVENT SHALL VALENCELL, INC., BE LIABLE FOR ANY
CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT,
TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE
MATERIALS.
No license is granted or implied under any patent or other rights owned by Valencell,
Inc., by the publication or transfer of the information contained herein. Unless
otherwise stated, words and logos marked with ® or ™ are trademarks registered or
owned by Valencell, Inc. Other products, services and names used in this document
may have been trademarked by their respective owners.
Patent Notice:
Protected by granted patents and/or patents pending: www.valencell.com/patents
Both Benchmark® and PerformTek® and the Benchmark and PerformTek designs are registered
trademarks of Valencell, Inc. and may not be used for any purpose without the express prior written
consent of Valencell, Inc.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.