For the latest list of supported pixel protocols of the P- Link and Pixelator system, please refer to ENTTEC’s support page:
https://www.enttec.com/support/supported-led-pixel- protocols/
Features
allow proper ventilation. Allow about 6” (20 cm) be-
tween this device and a wall.

external DC power and has appropriate terminals to connect the tape. Getting Started

To begin your installation please follow these steps.


5. When the unit turns on, you will be able to see its initial IP address on the LCD panel which looks like W.X.Y.Z, where each letter is a number between 0 and 255. Note that IP address down for later use. 6. The LCD displays the IP address of the unit at all times (except when it's booting), but if not possible to check the LCD, NMU App (available for Windows & Mac) can be used to detect the Pixelator on your network. NMU can be downloaded for free rom the ENTTEC website.
Basic Setup
ENTTEC Pixelator is a standard Art-Net node. Because of this, you can use the device with applications, consoles, desks, or controllers that are compatible with Art-Net to distribute Art-Net data via Ethernet network.
With the default profile, each Pixel Link port is mapped to its respective Art-Net Universe, allowing you to directly plug-in your Pixelator without the need for configuration.
Profiles are essential to the operational philosophy of the Pixelator. With a profile selected, the device knows how to utilize the many resources it can make use of to perform lighting control tasks.
Pixel Tape needs to be connected to the Pixel Link port

Each Profile contains configuration information for some or all of the following items:
These are the physical PIXEL Link ports (1-24)
These are the DMX over Ethernet universes. (Art-Net, ESP, Kinet, sACN)
The routing diagram is the visual representation of the Profile itself and it tells the Pixelator how frames are moved or routed inside the routing engine, as well as what to do with multiple sources of data that need to be merged, when that option is engaged. Other special operations can be part of a diagram as well, such as Channel Shifter, Output Switch, etc.
using a PLink Injector (sold separately). The injector takes

Line3: displays the number of packets currently passing through the Pixelator. This number of packets per second, can be used as an indicator of the activity of DMX on your network.
The Pixelator has a set of factory profiles, to start you off. You're likely to see 2 or more of the following:
Pressing any of the panel buttons/keys will activate the next screen on the LCD Menu. Selection Menu
These profiles are just an example of what can be done with the Pixelator, you can modify the factory profiles to accommodate your specific need, or create your own profile from scratch.
If you don't see any of the above, please contact support@enttec.com and we can send them to you. After that, you're on your own to make and edit profiles to suit your application!
Lists all available profiles on the Pixelator, list can be scrolled using up & down keys. Scrolling indicator is visible when the list allows scrolling. Pressing Enter at the selected profile will activate the profile 2-Setup
You may select between existing profiles via the menu, but to edit them and make new ones, you'll need to access the Pixelator's web page. The sections that follow will provide more information about each of the ways to interact with the Pixelator.
Changing from one profile to another can be done in a web browser window, or with the touch of a few buttons on the front panel (LCD menu).
LCD Menu
Setup screen allows changing the IP address of the unit via “Change IP” or doing Factory Reset. Change IP
The LCD Menu is navigated through the four panel buttons on the front of the unit.
The Menu button acts as the “Back” button, which takes you to the previous Menu/screen.
The Enter button goes into the selected option on the screen, and activating the option.
This screen further gives two options DHCP or Static IP. When Static IP is selected, the screen allows you to change the IP address using the top and bottom button to scroll the digits and the menu & enter buttons to select the segment. Once you are on the last segment of the IP address, pressing the Enter button, will activate the IP address. It will take a few seconds for the change to go through, please wait 30 seconds, before attempting to try again.
The Top & Bottom button are used to navigate/scroll through the options on any screen. The currently selected option is highlighted with a white background on the screen.

IP: 192.168.001.003
Activating Factory Reset, leads to a simple prompt confirming your action. Once confirmed, the Factory Reset will take a few seconds to run. It will end up deleting all your user created profiles, as well as any saved settings. Please use this only when needed, or as directed by ENTTEC support team.
Line1: displays the System Name and currently Selected Profile.
Line2: displays either the current IP address / DHCP Failed / disconnected, highlighting the current status of the network interface. The IP address is where the web interface can be accessed.
1-Load Profile · Factory Reset

F-Reset in progress please wait …
Once confirmed, Pixelator will stop the output engine and restart the system. While rebooting the LCD screen will change between a couple of screens, and the LCD Main Menu will only be visible, once the system is fully ready. (usually takes a minute)
Status Screen, allows the following two options:
1-System 2-Network
Web Interface
Both the Status screens are read-only and provide information about the system and Networking. These require no user-input and serve as a way of checking the performance of the unit. 4-Lock Unit
The Pixelator is configured, controlled and programmed through a web browser interface running on a computer system located on the same Local Area Network. Any modern web browser, such as Chrome, Firefox, Internet Explorer, Safari or Opera, running under any operating system, including Windows XP or Vista, Mac OS X or Linux can be used.
The option to lock your device by disabling the web interface has been added to provide a level of security to your installation and is available on RevB models. By locking your device, the web server becomes inactive meaning that your configuration cannot be modified. To lock and unlock your device follow these simple steps on the devices LCD menu.
Type the IP address (shown on the LCD Menu) into your web browser to access the Pixelator Web Interface.
Throughout the Web Interface, helpful hints are displayed when a user hovers the mouse over the “Help” icon?

ENTTEC strongly recommend you secure your network with relevant and. Do not connect devices carrying DMX or ArtNet data to the outside world unless absolutely necessary and with relevant precautions in place. If unsure consult a specialist within this field.
Restart Screen, when activated, prompts for the user to confirm the selection.
3-Status · 5-Restart



The PLink 2U module represents one of the physical ports on the rear of this unit, and maps to 2 Universe.
From this screen you can manage your profiles.
As you will notice in the "Remarks" column, the factory default profiles are read only. If you wish to modify one of them, you will first need to copy the profile to some other name. Once the profile has been copied you can modify it to fit your particular needs.
Clicking on the Profile name will launch the profile in the profile-editor window.
Create a new profile or edit an existing one using the profile-editor. Profile Editor opens in a new page in your web browser. Select a module on the left and the right panel will provide help about that panel. Connect a module to another using wires from one point to another.

The direction of the wire (arrow) is important, the arrow signifies output, and reflects the flow of data.
Art-Net Stream: "Send IP address": is the destination address used when the stream is sending data only.
Each profile is made up of two or more connected Modules or Actions. The relationship between them forms the layout of the data flow within the profile.

The following modules are available:
The PLink 1U module represents one of the physical ports on the rear of this unit, and maps to 1 Universe.
ESP Stream: ENTTEC Show protocol DMX over Ethernet stream (ESP). IP address is the destination address used when the stream is sending data only.

Kinet Stream: For example: You can connect Kinet Stream to an Art-Net Stream to convert and output as Art-Net. (Kinet stream is supported as input only).


Download the firmware to your desktop and then follow instructions on the Pixelator’s Settings page.
Streaming ACN: "IP address" is the destination address used when the stream is sending data only (default is disabled = 0.0.0.0)
If the web-page does not refresh automatically, please open the home page on the browser manually, and verify that the update has succeeded.


DMX Generator: Define your own custom DMX Channel values and assign the selected ones. Snapshot feature can be used to capture values from an input stream. All modifications can be done using the DMX Grid Page.

NMU (Node Management Utility) is a free Windows and Mac application that is used to manage compatible ENTTEC DMX over Ethernet nodes. NMU will not directly allow you to configure the Pixelator itself, but it can help you find your unit's IP address and then open a browser window to access Pixelator. Follow these steps:
Clock: Allows you to synchronize ALL Pixel Link output only when the connected Input Stream is received.
The Clock module can be used to make sure the output is always synced to the “latest universe” - especially if the source adds a delay to each universe.

You can update the firmware on the Datagate Mk2, via the web browser. Firmware files are available on the ENTTEC website. Always check your Pixelator’s hardware revision, (Rev A, B or C on the device homepage, to ensure you are downloading firmware that is compatible with your device).

Pixelator Specifications


Ordering Information To order Pixelator and related products from our website or through an ENTTEC dealer using the following part numbers.
Due to continuous improvements and innovations of all ENTTEC products, specifications and features are subject to change without notice.
73546 Plink Injector 5V
73544 Plink Injector 12-24V
Accessories and Related Products:
License The Wireit Library is distributed under the MIT License Distributed under the MIT License : Copyright (c) 2007-2010, Eric Abouaf Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions: The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software. THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.

70060 Pixelator
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.