Page 1 of the Zelmer 522.60 user manual — IMPORTANT SAFETY INSTRUCTIONS
Page 1 · click to enlarge
Page 1

EN

Table of contents Important safety instructions 58 Technical parameters 59 Features 60 Parts 60 Assembly 60 Setting the operation mode 61 Operation 62 Cleaning and maintenance 62 Ecology – Environmental protection 63

Dear Customers

Please read these instructions carefully. Pay special attention to important safety instruc tions to avoid accidents and/or damage to the appliance. Keep this User’s Guide for future reference.

IMPORTANT SAFETY INSTRUCTIONS

Read the entire instruction manual before operating the appliance. ––

The appliance is intended for household use only. The warranty conditions change ––

if the appliance is used in gastronomic business. Do not unplug by pulling on cord. ––

The cord cannot touch hot surfaces. ––

Do not operate the appliance if it has a damaged cord or if the housing is visibly damaged. ––

If the non-detachable part of the cord is damaged, it should be replaced by the producer or at a proper service point or by a qualified person in order to avoid any hazards. The appliance can only be repaired by qualified service personnel. Improper serv icing may cause a serious hazard to the user. In case of defects please contact a qualified service center.

The cooker hood is used to extract cooking fumes to the outside. It should be con ––

nected to an appropriate ventilation duct (do not connect to working chimney ducts, smoke ducts or exhaust fume ducts). The appliance should be installed at the height of at least 650 mm from the electric ––

cooking plate and at least 700 mm from a gas cooker. Do not leave an open flame under the cooker hood. Set the minimal flame while re ––

moving pots from the gas ring. Dishes prepared using fats should be constantly supervised, as overheated fat may ––

easily catch fire. Clean the cooker hood anti-grease filter at least every 2 months. A filter saturated with ––

grease is flammable. Unplug the appliance before each cleaning operation, before replacing the filter or ––

starting any repair works. If there are other appliances with non-electric supply (e.g. liquid fuel stoves, flow heat ––

ers, therms) in the room apart from the hood, a sufficient ventilation (air intake) should be provided. Safe exploitation is possible if during the simultaneous operation of the cooker hood and combustion appliances dependant on the air inside the room, the un derpressure in the place where those appliances are located amounts to 0.004 milibar at the highest (this does not apply if the cooker hood is used as the odor absorber).

Page 2 of the Zelmer 522.60 user manual — TECHNICAL PARAMETERS
Page 2 · click to enlarge
Page 2

Anti-grease filters as well as active-coal filters should be cleaned or replaced accord ––

ing to the recommendations of the manufacturer or more often, if they are intensively used (more than 4 hours a day). Always check if the flame does not exceed the pot, as this causes undesirable en ––

ergy losses and a dangerous heat concentration. Use the cooker hood only for its intended use. Do not wash under running water. Do not immerse the appliance and the cord into ––

water. Do not use abrasive detergents such as emulsions, cream cleaners, polishes, etc. to ––

clean the housing. They may remove the graphic information symbols such as: scales, marks, warning signs etc. The use of accessories not recommended by the manufacturer may cause damage to ––

the appliance. This appliance is not intended for use by persons (including children) with reduced ––

physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. ––

Make sure that the above instructions have been understood.

TECHNICAL PARAMETERS

Voltage 230 V ~ 50 Hz

Outlet [ø mm] 150 (120)

Efficiency – [m3/h] Max 380

Energy consumption [W] 150

Type of operation Wyciąg lub pochłaniacz

Color Stal nierdzewna INOX

The appliance meets the requirements of the applicable norms. The appliance is in conformity with the requirements of the directives:

Low voltage appliance (LVD) – 2006/95/EC. ––

Electromagnetic compatibility (EMC) – 2004/108/EC. –– The appliance was marked by a CE sign on the rating label.

Show 8 more labels / short text on this page
Features Hood type · Fan motor 1 · Lighting 40 W · Speed settings 3 · Width [cm] 60 · Depth [cm] 50 · Height [cm] 12 · Loudness [dBA] 52
Page 3 of the Zelmer 522.60 user manual — ASSEMBLY
Page 3 · click to enlarge
Page 3

FEATURES

ZELMER cooker hood is used to extract cooking fumes. It requires to install a duct ex tracting air to the outside. The length of the duct (most commonly a tube Ø 120 mm, 150 mm) should not exceed 4-5 m. After installing the active-coal filter which is available in the sales network, the cooker may operate as an odor absorber. In this case it is not required to install the duct extract ing the air to the outside, however it is recommended to install an air exhaust fin. The cooker hood is a class II electrical appliance. It is equipped with an independent lighting and an extract fan with three speed settings. The cooker hood is designed for a permanent installation on a vertical wall above the gas or electric cooker.

Zelmer 522.60 — FEATURES diagram (page 3)
Fig. 1

PARTS

The cooker hood is composed of

  • the following elements (fig. 1): The hood body C equipped with
  • the lighting and the fan unit. A telescopic chimney compris
  • ing of:
  • Upper chimney A.
  • Lower chimney B.
  • Air exhaust fin.
  • Reduction adaptor.
  • A set of rawlplugs.
Zelmer 522.60 — PARTS diagram (page 3)
Fig. 2

ASSEMBLY

In order to assemble the cooker hood:

1. Hang the hood body C. 2. Plug in the cooker hood. 3. Set the mode of the cooker hood (absorption or extrac tion mode). 4. Install the telescopic chimney column B and A.

Installing the cooker hood

a) Mark a vertical line on the wall indicating the center of

the kitchen plate. b) Dismantle the aluminum grease filter. c) Put the cooker hood housing against the wall with the

marked center on the vertical middle line, keeping the minimal distance of 650 mm from the surface of the kitchen.

Page 4 of the Zelmer 522.60 user manual — SETTING THE OPERATION MODE
Page 4 · click to enlarge
Page 4

d) Mark the position of the assembly holes on the wall. e) Drill the holes marked on the wall using a drill with the diameter corresponding to the

enclosed rawlplugs, insert the rawlplugs in the holes and fix the cooker hood housing to the wall. f) Install the aluminum anti-grease filter.

Installing the telescopic chimney column

In order to install the column (masking cover) of the cooker hood:

  • Insert the lower (B) and upper (A) chimney
  • (fig. 1) on the cooker hood housing, slide the masking cover apart for the desired height and mark it on the wall. Remove the upper chimney A and 65 mm
  • from the marked maximum point of the chim ney, place the chimney fixing section D sym metrically to the middle line, mark the holes on the wall, drill the holes, insert the rawlplugs E and screw the fixing section D. Place the upper chimney A onto the lower
  • chimney B, slide to the previously set height. Using the supplied screws F, screw the upper
  • chimney A to the fixing section D and the lower chimney B to the housing of the cooker hood.
Zelmer 522.60 — SETTING THE OPERATION MODE diagram (page 4)
Fig. 3

Plug in and operation control

After plugging the appliance in (according to the previously described requirements), check if the cooker hood lighting works and if its motor operates correctly. After installing the cooker hood, the socket should be easily accessible in order to unplug the appliance.

SETTING THE OPERATION MODE

Setting the extraction operation mode

During the extraction mode, air is extracted to the outside with a special duct. Remove the coal filters with this setting. The cooker hood is connected to an opening that extracts the air to the outside with a stiff or flexible duct with the diameter of 120 mm, 150 m and appropriate duct clamps which are to be purchased in installation materials supply stores. The installation should be performed by a qualified fitter.

Setting the odor absorber operation mode

While using this mode, filtered air comes back to the room through openings on both sides of the upper chimney. While using this mode, the coal filter should be installed, it is also recommended to install an air exhaust fin.

The speed of the fan

The lowest and medium speed settings are used in normal conditions and low cooking fume intensity. The highest speed setting should be used only in case of an intense level of cooking fumes e.g. during frying or grilling.

Page 5 of the Zelmer 522.60 user manual — CLEANING AND MAINTENANCE
Page 5 · click to enlarge
Page 5

OPERATION

The cooker hood can be controlled using an integrated switch. 0 – motor off, 1 – first operation speed, 2 – second operation speed, 3 – third operation speed, – light on/off.

Zelmer 522.60 — OPERATION diagram (page 5)
Fig. 4

This adjustment allows to set the optimal fan speed for the user’s needs with a minimal noise level.

CLEANING AND MAINTENANCE

Regular cleaning and maintenance will guarantee a good and failure-free operation of the cooker hood and will prolong its useful life. Make sure the aluminum filters and the active-coal filters are replaced according to the manufacturer’s recommendations.

1. Cleaning In case of a normal operation of the cooker hood, the aluminum anti-grease filters should be cleaned every two months in a dishwasher or manually with the use of a mild detergent or liquid soap.
2. Replacement To dismantle the filters: a) Remove the lower cover by releasing the catch. b) Take out the aluminum anti-grease filter.
Zelmer 522.60 — CLEANING AND MAINTENANCE diagram (page 5)
Fig. 5

Coal filter (available at sales network)

1. Operation Coal filters are used only when the cooker hood is not connected to the ventilation duct. Active-coal filters can absorb odors until they are saturated. Active-coal filters can not be washed or regenerated; they should be replaced at least every two months or more often if the cooker hood is intensively used.

Control panel · Maintenance · Anti-grease aluminum filters

Page 6 of the Zelmer 522.60 user manual — ECOLOGY – ENVIRONMENT PROTECTION
Page 6 · click to enlarge
Page 6
2. Replacement a) Remove the aluminum anti-grease filter. b) Remove the coal filter located inside the cooker hood, on the motor housing (on both

sides of the motor) by twisting it off. c) Proceeding in the reverse order than indicated in point b, install the new filter on

the motor turbine housing and turn it to protect against falling out.

Zelmer 522.60 — ECOLOGY – ENVIRONMENT PROTECTION diagram (page 6)
Fig. 6

The lighting installation is composed of a 40 W light bulb. In order to replace a damaged light bulb: a) Unplug the appliance. b) Remove the aluminum filter from the cooker hood housing. c) Replace the damaged light bulb using a cloth or paper. d) Reinstall the aluminum filter.

During the normal cleaning process do not:

  • Use soaked cloths, sponges or running water.
  • Use solvents or alcohol, as they may tarnish the lacquered surfaces.
  • Use corrosive substances, especially for cleaning stainless steel surfaces.
  • Use a hard, rough cloth.

It is recommended to use a damp cloth and neutral cleaning agents.

ECOLOGY – ENVIRONMENT PROTECTION

Each user can protect the natural environment. It is neither difficult nor ex pensive. In order to do it: put the cardboard packing into recycling paper container; put the polyethylene (PE) bags into container for plastic. When worn out, dispose the appliance to particular disposal centre, because of the dangerous elements of this appliance, which can be hazardous for natural environment.

Do not dispose into the domestic waste disposal!!!

The manufacturer/importer does not accept any liability for any damages resulting from unintended use or improper handling. The manufacturer/importer reserves his rights to modify the product any time in order to adjust it to law regulations, norms, directives, or due to construction, trade, aesthetic or other reasons, without notifying in advance.

Lighting · Cleaning

Page 7 of the Zelmer 522.60 user manual — ECOLOGY – ENVIRONMENT PROTECTION
Page 7 · click to enlarge
Page 7

522-001

Ask about the Zelmer 522.60

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Zelmer 522.60

Be the first to ask — other owners or our team will answer.

Original document

Zelmer 522.60 manual PDF

64 pages·1014 KB·Kitchen Range Hood·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…