Auto-Restart presetting Function: To set the auto-restart function, press the Emergency button (ON/OFF) on the indoor unit for at least 5 seconds A buzz sound will signal that the auto-restart function is set and the air conditioner is in standby. To cancel the auto-restart function, repeat the above steps.
Before using the appliance please follow and set according to the below indications: Remote Control (RC) presetting: Each time the batteries are replaced in the remote control, the RC is pre-set on Heat pump. If the air conditioner that you purchased is a cooling only, then the pre-set on Heat pump will not bring any changes.

SCRAPPING OF PACKAGING • The packaging can be 100% recycled as confirmed by the recycling symbol . The various parts of the packaging must not be dispersed in the environment, but must be scrapped in line with local authority regulations.


Indoor unit 1. Air Intake 2. Front Panel 3. Display panel 4. Electrical box 5. Air Outlet 6. Filter monitor reset button 7. Vertical Adjustment Louver 8. Horizontal Adjustment Louver 9. Air Filter 10.Remote Control
Outdoor unit 11. Air Intake 12. Pipes and Power Connection Cord 13. Drain Hose Note: Condensate water drains at COOLING or DRY operation. 14. Air Outlet
Images in the user instructions are based on external views of standard models, shape and design vary according to the model.

Temperature indicator (1) Displays set temperature.
Running indicator (2) It lights up during operation. It flashes during outside unit defrosting.
Timer indicator (3) It lights up during the set time. It goes off when timer operation ends.
Sleep indicator (4) It lights up during sleep mode.
Filter monitor indicator (5) Filter monitor indicator flashes after 240 hours of usage as reminder to clean the filter. After filter cleaning press the reset button located on the indoor unit behind the front panel in order to interrupt the flashing of the filter monitor indicator.
Emergency ON/OFF button (6) Used to control the unit by pressing the button, when the RC is out of work. Used to set or cancel auto-restart function.

Signal Receptor (7)


6. BUTTON Used to set or cancel 6th sense operation, also during stand-by. 7. SLEEP BUTTON Used to set or cancel Sleep Mode operation. 8. FAN BUTTON Used to select fan speed in sequence auto, high, medium or low. 9. SWING BUTTON Used to stop or start vertical adjustment louver swinging and set the desired up/down airflow direction. 10. JET BUTTON Used to start or stop the fast cooling. (Fast cooling operates at high fan speed with 18°C set temp. automatically).
Display set temperature Display set timer
Adjust Temperature (±2°C) indicator in 6th sense mode

How to insert the batteries Remove the battery cover in the direction of the arrow. Insert new batteries making sure that the (+) and (-) of battery are matched correctly. Refit the cover by sliding it back into position.

How to remove the batteries Remove the battery cover in the direction of the arrow. Press the positive pole of the battery softly with your fingers, then draw the batteries out of the compartment. All this should be done by adults, children are forbidden to remove the batteries from the remote control in order to avoid danger of swallow.

Disposal of the batteries Please discard the batteries as sorted municipal waste at the accessible collection point.
To operate the air conditioner, point the remote control at the signal receptor. The remote control will operate the air conditioner at a distance of up to 7m.

Operation Modes:

↑ Heating mode is not available for cooling only air conditioners.
↑ At "FAN ONLY" mode, only "High","Medium" and "Low" are available. At "DRY" mode, Fan speed is set at "Low" automatically, "FAN" button is ineffective in this case.
*Note: Heating mode is NOT available for cooling only models.
During mode changes wait a few seconds and repeat the operation if the unit does not respond at once. When selection the heating operation, air flow will start after 2-5 minutes.


*Heating mode is only available for heat pump models.
Vertical airflow control (using the remote control) Use the remote control to set the flow angles.
Swinging airflow Pressing "SWING" button once, the vertical adjustment louver will swing up and down automatically.
Desired direction airflow Pressing the "SWING" button again when the louvers swing to a suitable angle as desired.
Horizontal airflow control (with hands) Turn the control rods of the horizontal adjustment louvers to change horizontal air flow as shown.

A - Do not turn the vertical adjustment louvers
manually, otherwise malfunction may occur. If that happens, turn off the unit first and cut off the power supply, then restore power supply again. B - It is better not to let the vertical adjustment
louver tilt downward for a long time at COOLING or DRY mode to prevent condensed water from dripping.

6th SENSE MODE Press the button, the unit enters 6th sense mode directly regardless of the unit is on or off. In this mode, temperature and fan speed are automatically set based on the actual room temperature.

Operation mode and temperature are determined by indoor temperature.
Button is ineffective in Jet mode. Note: Temperature, airflow and direction are controlled automatically in 6th sense mode. However, a decrease or rise of up to 2°C can be set with the remote control if you still feel uncomfortable.
What you can do in 6th sense mode



*Note: In cooling mode, if room temperature is 26°C or above, set temperature will not change. Note: Heating is NOT available for cooling only air conditioner.


Timer function It is convenient to set the timer on by pressing the button to achieve a comfortable room temperature at the time you get home. You can also set timer off automatically to enjoy a good sleep at night.

Timer-setting Set the timer when the appliance is off.
Switch-off timer during operation.
A - As time goes by, LCD on remote control only
displays the remaining time not the set temperature. B - The previous set time is stored and the next
set time begins with the previous setting. C - On- timer and Off-timer cannot be set at the
same time. D - The room may not reach your desired
temperature within the preset time this depends on the size of the room.
Example: setting the next operation after 9.5 hours 1. Set desired operating mode, temperature and indoor fan speed, then press the TIMER button; "h" flashes on display. 2. Point the remote control at the signal receptor of the indoor unit, press the or button when "h" flashes. Choose the time you desire, then press the TIMER button, a "beep" can be heard. A - Timer indicator on the indoor unit lights up. B - "h" stops flashing. Press the TIMER button, "h" flashes on the display, then you can set the time. Each time the or button is pressed, If the desired time is within 10 hours, the set time increases or decreases by 0.5 hour; If desired time is beyond 10 hours, increases or decreases by 1 hour. The range can be set is 0.5 hour to 24 hours. 3. To cancel the set timer: press the TIMER button again, a "beep" can be heard and the timer indicator on the indoor unit lights off.




Unit 1. Unplug from the power supply Turn off the appliance first before disconnecting from power supply. 2. To remove the front panel pull it outwards (Fig. A). 3. Wipe with a soft and dry cloth. Use lukewarm water (below 40°C) to clean if the appliance is very dirty. 4. Never use substances such as gasoline or polishing powder to clean the appliance. 5. Never sprinkle water onto the indoor unit Dangerous! Electric shock! 6. Refit and close the front panel (Fig. B). Refit and close the front panel by pushing it downward.

Fig. A

Air filter It is necessary to clean the air filter after using it for about 100 hours. Clean the air filter every two weeks if the air conditioner operates in an extremely dusty environment. 1. Unplug from the power supply Turn off the appliance first before disconnecting from power supply and remove the air filter. 1. Open the front panel. 2. Press the handle of the filter gently. 3. Slide out the filter. 2. Cleaning and refitting the air filter. If the filter is very dirty, clean it with a solution of lukewarm water and neutral detergent. After cleaning let it dry. 3. Close the front panel.
Fig. B

Operating condition The protective device maybe trip and stop the appliance in the cases listed below.
*For Tropical (T3) Climate condition models, the temperature point is 52°C instead of 43°C. If the air conditioner runs in COOLING or DRY mode with door or window opened for a long time when relative humidity is above 80%, dew may drip down from the outlet.

Noise pollution • Install the air conditioner at a place that can bear its weight in order to operate more quietly.

Features of HEATING mode Preheating 2-5 minutes are necessary to preheat the indoor unit at HEATING operation start.
Defrosting (out door unit) In HEATING operation the appliance will defrost (de-ice) automatically to raise efficiency. This procedure usually lasts 2-10 minutes. During defrosting, fan stops operation. After defrosting completes, it returns to HEATING mode automatically. Note: Heating is NOT available for cooling only air conditioner models.
Features of protection device 1. Protection device Wait at least 3 minutes before restarting the unit after operation stops or changing mode during operation. After connecting to power supply and turning on the appliance immediately, a delay of 20 seconds may occur before it starts to operate. 2. If all operation has stopped, press ON/OFF button again to restart. Timer should be set again if it has been cancelled.
Operation problems are often due to minor causes that can be found and fixed without using any tools:
No cooling or heating air
Does not operate immediately • 3 minute delay will occur when changing mode during operation.
Peculiar smell • This smell may come from another source such as furniture, cigarette etc, which is sucked in the unit and blown out with the air.
A sound of running water
Cracking sound • The sound may be generated by the expansion or contraction of the front panel due to temperature changes.
Mist sprays from the outlet
Trouble Analysis · Does not run · Ineffective control


Air intake distance from the wall should be over 250mm
Air intake distance from the wall should be over 250mm
Air outlet distance from the wall should be over 500mm
Installation diagram

Pipe length is 15 meters Max.
be less than 5m
Pipe length is 15 meters Max.
Height should be less
Model Max. Allowable Tubing Length at
of additional refrigerant (g/m)



Wall hole sleeve (hard polythene tube prepared by user)



Thermal Insulation piping: a. Place the drain hose under the piping. b. Insulation material: polythene foam over 6mm in

thickness.
Defrost cable (for heat-pump) Drain hose (prepared by user)

A. Insert the pipe fixer to the slot. B. Press to hook the pipe fixer onto the base.


special attention to the torque allowed as shown below to prevent the pipes, connectors and flare nuts from being deformed and damaged. b. At first fingers-tighten them, then use the wrenches.


CAUTION: 1. Use an individual power circuit specifically for the air conditioner. As for the wiring method, refer to the circuit diagram on the inside of the access door . 2. Check that the cable thickness conforms to the power source specification. 3. Check the wires and make sure that they are all tightly fastened after cable connection. 4. Be sure to install an earth leakage circuit breaker in a wet or moist area.
Power cord Power connecting cord Power connecting cord 1 Main power supply (Note) Type Normal cross -
sectional area Type Normal cross -
sectional area Type Normal cross -
7K,9K,12K H05VV-F 1.0~1.5mm² X3 H07RN-F 1.0~1.5mm²X3 H05RN-F 0.75mm²X2 (Heat-pump) To indoor
RVV 1.5~2.0mm² X3 H07RN-F 1.5mm²X3 H05RN-F 0.75mm²X2 (Heat-pump) To indoor
24K H07RN-F 2.5mm² X3 H07RN-F 1.5mm²X3(Heat-pump) 1.5mm²X4(Cooling-only) H05RN-F 0.75mm²X3 (Heat-pump) To outdoor
Make sure that the colour of wires of the outdoor unit and the terminal number are the same as those of the indoor unit.
1(N)
2(L)
1(N)
2(L)
3(SI)
3(SI)
YE/GN
Indoor unit control board
AC L-IN
BU
AC N-IN



Defrost cable (for heat pump models only)
After connection, the defrost wire should be well wrapped with a wrapping tape and the connector should be put inside the unit.


Air purging Air containing moisture remaining in the refrigeration cycle may cause a malfunction on the compressor. After connecting the indoor and outdoor units, evacuate air and moisture from refrigerant cycle using a vacuum pump, as shown below. Note: Because the system pressure is high and also to protect the environment, be sure not to discharge the refrigerant to the air directly.


How to Purge Air Tubes: (1). Unscrew and remove caps from 2 and 3-way valves. (2). Unscrew and remove cap from service valve. (3). Connect vacuum pump flexible hose to the service valve. (4). Start vacuum pump for 10-15 minutes until it reaches an absolute vacuum of 10 mm Hg. (5). With vacuum pump still running close the low pressure knob on vacuum pump manifold. Then stop
vacuum pump. (6). Open 2-way valve 1/4 turn, then close it after 10 seconds. Check tightness of all joints using liquid
soap or an electronic leak detector. (7). Turn 2 and 3-way valves stem. Disconnect vacuum pump flexible hose. (8). Replace and tighten all valve caps.