CRS-2/IR, CRS-3/IR Express® Crescent® Lavatory System CRS-Series Complies with T exas Accessibility St andards (T AS) for Juvenile Height applications. Inst allation Instructions P .O. Box 309, Menomonee Falls, WI 53052-0309 TEL. 1-800-BRADLEY F AX 262-251-5817 http://www .
Express ® Crescent ® Lavatory System - CRS-Series CRS-2/IR, CRS-3/IR Installation Instructions 2 2/8/07 Bradley Corporation • 215-1330 Rev . K; EN 06-915 Express® Crescent® Lavatory System Dimen.
Express ® Crescent ® Lavatory System - CRS-Series Installation Instructions CRS-2/IR, CRS-3/IR 3 Bradley Corporation • 215-1330 Rev . K; EN 06-915 2/8/07 Inst allation Instructions Supplies required for inst allation: • (6) 3/8" wall anchors, bolts and washers to mount bowl to wall (min.
Express ® Crescent ® Lavatory System - CRS-Series CRS-2/IR, CRS-3/IR Installation Instructions 4 2/8/07 Bradley Corporation • 215-1330 Rev . K; EN 06-915 * ADJUSTMENTS TO VERTICAL DIMENSIONS FOR V.
Express ® Crescent ® Lavatory System - CRS-Series Installation Instructions CRS-2/IR, CRS-3/IR 5 Bradley Corporation • 215-1330 Rev . K; EN 06-915 2/8/07 Inst allation Instructions continued . . . Step 3: Inst all wall anchors 1. Measure and mark the centerline of the lavatory system on the wall.
Inst allation Instructions continued . . . Step 6: Inst all drain spud 1. Assemble the P-trap by (supplied by installer) connecting the 1-1/2" tubular pipe to the 1-1/4" tailpiece and to the 1-1/2" drain pipe stubbed out of the wall (see Figure 4).
Express ® Crescent ® Lavatory System - CRS-Series Installation Instructions CRS-2/IR, CRS-3/IR 7 Bradley Corporation • 215-1330 Rev . K; EN 06-915 2/8/07 Inst allation Instructions continued . . . Step 8: Electrical and supply connections NOTE: Refer to Figur e 6a below for CRS-2/IR or Figur e 6b on page 8 for CRS-3/IR.
Inst allation Instructions continued . . . Step 8: Electrical and supply connections, cont’d. 6. Check the temperature when approximately 1.0 GPM water flow is reached and adjust if necessary (the range of the valve is 95°F–1 15°F (35°C–43°C).
Express ® Crescent ® Lavatory System - CRS-Series Installation Instructions CRS-2/IR, CRS-3/IR 9 Bradley Corporation • 215-1330 Rev . K; EN 06-915 2/8/07 Inst allation Instructions continued . . . Step 9: Inst all the Optional Soap Dispenser For Expr ess® Cr escent® Lavatory System units with optional soap dispensers, see 215-1583.
Express ® Crescent ® Lavatory System - CRS-Series CRS-2/IR, CRS-3/IR Installation Instructions 10 2/8/07 Bradley Corporation • 215-1330 Rev . K; EN 06-915 Cleaning and Maintenance Instructions IMPORT ANT : Strong alkaline or acid-based chemicals and cleansers should not be used to clean the Crescent®.
Express ® Crescent ® Lavatory System - CRS-Series Installation Instructions CRS-2/IR, CRS-3/IR 11 Bradley Corporation • 215-1330 Rev . K; EN 06-915 2/8/07 Solenoid V alve T roubleshooting CAUTION: T urn off water supplies to unit before troubleshooting.
Express ® Crescent ® Lavatory System - CRS-Series CRS-2/IR, CRS-3/IR Installation Instructions 12 2/8/07 Bradley Corporation • 215-1330 Rev . K; EN 06-915 1 2 3 4 5 6 7 8 9 8 DE S CRIPTION QTY .
Thermost atic Mixing V alve T roubleshooting NOTE: Befor e attempting to tr oubleshoot the valve or disassemble the components, check for the following conditions: • If stop/check valves ar e used, make sur e that they ar e fully open.
Express ® Crescent ® Lavatory System - CRS-Series CRS-2/IR, CRS-3/IR Installation Instructions 14 2/8/07 Bradley Corporation • 215-1330 Rev . K; EN 06-915 V ernatherm™ Thermost atic Mixing V alv.
An important point after buying a device Bradley Smoker CRS-2/IR (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Bradley Smoker CRS-2/IR yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Bradley Smoker CRS-2/IR - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Bradley Smoker CRS-2/IR you will learn all the available features of the product, as well as information on its operation. The information that you get Bradley Smoker CRS-2/IR will certainly help you make a decision on the purchase.
If you already are a holder of Bradley Smoker CRS-2/IR, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Bradley Smoker CRS-2/IR.
However, one of the most important roles played by the user manual is to help in solving problems with Bradley Smoker CRS-2/IR. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Bradley Smoker CRS-2/IR along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center