EN
Steba logo
Official user manual

Steba LB10

24 pages·942 KB·Humidifier-Dehumidifier·PDF·ENITNLJA
Steba LB10
Table of Contents 12 sections Safety information · Cleaning · ON/OFF · Ultrasound · … ShowHide
Page 1 of the Steba LB10 user manual — Safety information
Page 1 · click to enlarge
Page 1
Steba LB10 — Safety information diagram (page 1)
Fig. 1 · Safety information

1 Mist output nozzle

Steba LB10 — Safety information diagram (page 1)
Fig. 2 · Safety information

220-240 V ~ 50 Hz, 105 W

Generally This appliance is for private and indoor use only and must not be used commercially. Please read the instruction manual carefully and keep it at a safe place. When the appliance is given to ano- ther person the instruction manual should be passed to that per- son, too. Only use the appliance as described in the instruction manual and pay attention to the safety information. No liability for damages or accidents will be accepted, which are caused by not paying attention to the instruction manual.

Safety information

∙∙The appliance must only be plugged into a socket and used according the technical data given on the rating label ∙∙Only use the appliance when the power cord or the appliance has no damage. Check before each use.

Show 4 more labels / short text on this page
2 Water tank · 3 LED Display · 4 Basin · 5 Filter
Page 2 of the Steba LB10 user manual — Safety information
Page 2 · click to enlarge
Page 2

∙∙Place the power cord in that way that the appliance can not fall down. ∙∙

The appliance can be used by children aged 8 and above and persons with limited physical, sensory or mental capa- bilities or lack of experience/knowledge, provided that are su- pervised or have been provided with instruction in the safe use of the appliance and have understood the resulting dangers. Children must not use the packaging as a plaything. Cleaning and user maintenance must not be carried out by children un- less they are 8 years or older and are supervised. ∙∙Children under the age of 8 must be kept away from the appli- ance and the connecting cable. ∙∙The appliance must not be operated using a timer or a separate remote system! ∙∙Unplug the appliance after each use or in case of a malfunction. ∙∙Never pull at the power cord. The power cord must not be torn over edges and it must never be squeezed. ∙∙The power cord must not be touched with wet hands. ∙∙Never leave the appliance unattended during the use. ∙∙The appliance must not be stored outside or in a damp environment. ∙∙Never immerse the appliance into water. ∙∙The appliance should be switched off when the water tank is empty or when it should not be used. If the appliance is not used for longer time, it should be unplugged and cleaned. ∙∙After any malfunction the appliance should not be used anymo- re, e.g. after is fell down or was damaged in any other way. ∙∙The manufacturer takes no responsibility for wrong usage which is caused by ignoring the instruction manual. ∙∙Any repairs at the appliance, e.g. exchange a damaged power cord must be done by an authorized service person, to avoid any danger. ∙∙When any abnormal smell occurs is it important to switch off the appliance and contact the service. ∙∙Do not place the opening for the mist against any electrical appliances or sockets.

Page 3 of the Steba LB10 user manual — Cleaning
Page 3 · click to enlarge
Page 3

∙∙Do not direct the air vents on sockets, furniture, books, compu- ters, etc. ∙∙To relocate the appliance, disconnect it from the supply system. Do not tilt or move during operation.

Cleaning

∙∙The appliance must be cleaned more often the harder the wa- ter is. Too much lime disturbs the correct working of the appli- ance and leads to the formation of scale. In this case use boiled or distilled water. In any case do not use carbonated mineral water! ∙∙

Unplug the appliance first. Never immerse the appliance into water. ∙∙The appliance must be unplugged and the water must be re- moved from the base and out of the water tank by opening the cover at the bottom of the water tank and pour out the water. Only close the water tank again when the appliance should be used again, else the water tank should dry up completely. ∙∙Scale remains at the base, the transductor and the water tank should be wiped away. It is essential, that the transductor is not damaged. When there is excessive scale some scale remover should be used or fill vinegar in the bassin. After some time, depending on deposit, the scale dissolved. After this the base must be cleaned completely with clean water. The filter should be put into salty water (1 spoon salt per litre) for one day for recovery. Then rinse the filter with clear water and shake it and then let it dry. ∙∙Steba tipp: Weekly cleaning avoids white sediments. Bacteria and germs will not have a chance! When the device is regularly used, its cleaning will be easier and quicker. ∙∙Carefully clean the ultrasonic membrane at the bottom part with a brush. Scale reduces the atomization. Reassemble the appliance and store in a dry place up till next usage.

Page 4 of the Steba LB10 user manual — Ultrasound
Page 4 · click to enlarge
Page 4
Steba LB10 — ON/OFF diagram (page 4)
Fig. 3

9 8 7 6 5

1. Room temperature 2) Humidity 3) Ionization 4) Ultrasound 5) Water level
6. Water preheating 7) Sleeping mode 8) Humidity 9) Timer

Connect the plug with the mains socket. A beep sound is heard, and the display shows the current room temperature and humidity.

ON/OFF

BY touching the button

button again the device turns off again.

Ultrasound

button you can adjust the atomization power in 3 levels. ∙∙Your air humidifier always starts with the medium program ∙∙The percentage of water mist in a room and the air temperature are together the relative humidity. The correlation between mist and air is varying at the different temperatures. The higher the temperature is, the less water mist can be in the air. ∙∙In winter time the cold air comes from the outside and gets warmer by the room temperature. The relative humidity is getting lower. The humidity must be increa- sed by a humidifier. ∙∙The relative humidity in a room should be: bedroom or living room: 45-60% ∙∙sickroom: 40-50% ∙∙library: 40-50%

the display shows · By pressing the · By pressing the

Page 5 of the Steba LB10 user manual — Ionization
Page 5 · click to enlarge
Page 5

Preheating

button the water will be slightly preheated to guarantee that the water mist does not withdraw too much temperature from the ambient air. Ener- gy consumption 100W. The display shows

. By pressing once again, the heating is stopped.

Timer

button you can adjust the time up to 9 hours in steps of one hour. The display shows the symbol

. By pressing the button again, the display shows “C” for continuous working.

Humidity

. The display shows the current humidity. Chose the humidity level from 40 – 90% und confirm within 3 seconds by pressing once again. The recommen- ded humidity is 45%-60%. As soon as the device has reached the adjusted humidity in the room, it switches off.

Sleeping mode

By pressing this button the device works with a humidity of 65 – 70%. Display illumi- nation and beeping are shut down. As soon as the device has reached the adjusted humidity in the room, it switches off. By pressing once again the button

the slee- ping mode is turns off.

Ionization

By pressing the “Ionization” button the water mist will be enriched with negative ions. This effect is like after a summer thunderstorm. Quantity of ions per cubic centi- meter of air: at high mountain 8000 ion/ccm at the sea 4000ion/ccm at the countryside 1200ion/ccm in the city 200ion/ccm in the office only 20 ion/ccm

Water level: If no water is in the tank, the atomization will be interrupted and the display shows a LED.

By pressing the · By pressing the · Press the button

Page 6 of the Steba LB10 user manual — Troubleshooting
Page 6 · click to enlarge
Page 6

Air filter cartridge: Depending on the working time and the surrounding of the humidifier, the cartridge should be replaced from time to time because it decreases the mist level.

Aroma cartridge: To receive scented mist, you can put some drops of scented oil onto the fleece.

Tipps:

∙∙Fill in lukewarm water into the tank and not the basin. Please wipe if some water drops may form on the housing because the housing might become splotchy. ∙∙Please empty the device if the room temperature is below 0°C. The building of ice damages the membrane. ∙∙Do not transport the device if too much water is in the basin. Unplug the device and empty some water. ∙∙Do not put any chemicals, detergent, metal etc. into the basin.

Troubleshooting

Failure Possible Reason Solution

Power light works not

No Power Please check if the unit is plugged in and the power button is pressed.

Light is on but no mist

No water in tank Fill water in the tank. Check if the water tank is attached correctly.

Smell Dirty or old water Clean the tank and the base completely and let it dry open at least 2 hours

Light is on, the appliance does not work

Too much water in the water tank

Fasten the tank lid and take out some water from the basin.

Low mist level Scale on the mem- brane

Clean the membrane and refill with new water.

Page 7 of the Steba LB10 user manual — Correct Disposal of this product
Page 7 · click to enlarge
Page 7

Correct Disposal of this product

This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustaina- ble reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.

Packaging disposal: Do not throw away the package materials. Please put it in the recycling bin.

Gift box: Paper, should be put to the old paper collection point. Plastic packaging material and foils should be collected in the special collection containers.

Service and Repair: If the appliance must be repaired, please get in touch with your trader or with the manufactu- rer:

STEBA Elektrogeräte GmbH & Co KG Pointstr. 2, 96129 Strullendorf / Germany

Distribution-Tel.: 09543 / 449-17 / -18, Service-Tel.: 09543 / 449-44, Fax: 09543 / 449-19 e-Mail: elektro@steba.com Internet: http://www.steba.com

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Steba LB10

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Steba LB10

Be the first to ask — other owners or our team will answer.

Original document

Steba LB10 manual PDF

24 pages·942 KB·Humidifier-Dehumidifier·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…