Congratulations! You have just acquired the exceptional Air Humidifier «FRED». It will give you great pleasure and improve the indoor air for you. As with all domestic electrical appliances, particular care is needed with this model also, in order to avoid injury, fire damage or damage to the appli- ance. Please study these operating instructions carefully before using the appliance for the first time and follow the safety advice on the appliance itself.
Description of the appliance The appliance consists of the following main components: 1. Air humidifier 2. Power cord for power supply 3. Metal-plated feet 4. On/Off switch 5. Output selector switch 6. Hygrostat 7. External steam pipe 8. Cover appliance with opening aid 9. Water tank with cover and integrated carrier handle 10. Cover for heating plate 11. Holder for heating plate cover 12. Clip for heating plate cover holder 13. Sealing for cover 14. Anti-limescale magnetic ball 15. LED for operation (power) 16. LED for output (blue=high, green=economy) 17. Display Tank empty (LED)

Cleaning · Repairs/disposal

If the air humidifier FRED has been placed in the desired place: Connect the 1. power cord (2) to the socket in your household. Remove the steam pipe (7) and lift off the cover (8). Fill the water tank (9) with water (make sure to hold inlet opening slightly up) – screw on the cover properly and check whether the cover is tight. Reinsert the water tank in the air humidifier, screw on the cover and insert the steam pipe. Place the appliance in the room. Take care not to place it on a floor which 2. might be damaged by water, and that there are no appliances or furniture sensitive to dampness close to it. Operate FRED via the On/Off switch (4) and select the desired output (5) 3. (blue=high, green=economy). If the appliance stops steaming, the display Tank empty (15) will be illuminated, then refill the water according to item 1. Use the hygrostat (6) to set the humidity. The setting range starts at 20 4. and ends at 90% relative humidity. We recommend setting the unit to 45% humidity for a convenient room climate (in the middle of the setting range, horizontal switch position). PLEASE NOTE: If the air humidifier fails to steam after 5 minutes, turn the hygrostat all the way to the right (max.). This may be due to the actual room humidity being higher than the value you have set. You may then gradually reduce the hygrostat. When the pilot lamps go out, you have reached the ambient room humidity. If the air humidifier switches off automatically while in operation, the desired room humidity has been reached. The air humidifier resumes operation when the room humidity falls below the preset value.
If the appliance is filled with a sufficient amount of water and stops never- 5. theless, start the descaling process (see cleaning).
Specifications Output normal (300 W, 360g/h) – eco (200 W, 175g/h) Voltage: 230V / 50Hz Dimensions 363 x 267 x 363 mm (width x height x depth) Weight ca. 3.4 kg Automatic shut-off yes, triple security Tank capacity 3.7 litres Sound level less than 26dB(A) Complies with EU regulations: GS/CE/WEEE/RoHS
All rights for any technical modifications are reserved

Setting up/operation