Contact Imager Bar Code Reader






Datalogic ADC, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic ADC, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic ADC”). Owners of Datalogic products are hereby granted a non- exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation. Should future revisions of this manual be published, you can acquire printed versions by con tacting your Datalogic representative. Electronic versions may either be downloadable from the Datalogic website (www.datalogic.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other Datalogic publi cations, please let us know via the "Contact Datalogic" page.
Disclaimer Datalogic has taken reasonable measures to provide information in this manual that is com plete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many coun tries, including the U.S.A. and the E.U. All other brand and product names may be trademarks of their respective owners.
This product may be covered by one or more of the following patents:
Design Patents: EP2137570. Utility Patents: EP0789315B1; US5481098; US5992740; US6098883; US6454168; US6561427; US7506816.
Additional patents pending.








Contents · viii Touch TD1100

Introduction
About the Touch TD1100
The Touch™ TD1100 series of linear imaging contact readers represent the Datalogic ADC solution for customers who require a cost-effective solution for close contact bar code reading without sacrificing quality and performance.
Designed for low throughput applications within multiple markets, the Touch TD1100 readers provide the guarantee of contact reading with an excellent reading performance on virtually all linear bar codes, including damaged or poorly printed codes.
Small, lightweight and low on energy consumption, the Touch TD1100 readers can still provide robustness and a 1.5 m / 5.0 ft drop resistance, which is typically included in a higher range of products.
The Touch readers are available with the option of two different sizes of reading windows: 6.5 cm / 2.6 in (Touch 65) or 9.0 cm / 3.5 in (Touch 90), which benefits the user when reading either standard or wide bar codes.
The Touch 65/90 Pro readers provide a complete all-in-one multi-interface solution, including RS-232, USB, and Keyboard Wedge Emulation, while the Touch Lite 65/90 readers provide USB-only or RS-232 / Keyboard Wedge interfaces.
This Product Reference Guide (PRG) is provided for users seeking advanced technical information, including connection, programming, maintenance and specifications. The Quick Reference Guide (QRG) and other publications associated with this product are downloadable free of charge from the website listed on the back cover of this manual.
Typically, units are factory-programmed for the most common terminal and communications settings. If you need to modify any programmable settings, custom configuration can be accomplished by scanning the programming bar codes within this guide.
Programming can alternatively be performed using the Datalogic Aladdin™ Configuration application which is downloadable from the Datalogic website listed on the back cover of this manual. This multi-platform utility program allows device configuration using a PC. It communicates to the device using a serial or USB cable and can also create configuration bar codes to print.
Chapter 1, Introduction provides a product overview, unpacking instructions, and cable connection information.

Chapter 2, Setup presents information about unpacking and setting up the reader, and interface configuration bar codes and details.
Chapter 3, Configuration Using Bar Codes provides instructions and bar code labels for customizing your reader. There are different sections for interface types, general features, data formatting, symbology-specific and model-specific features.
Chapter 4, References provides details concerning programmable features.
Appendix A, Technical Specifications lists physical and performance characteristics, as well as environmental and regulatory specifications. It also provides standard cable pin-outs and descriptions of the functions and behaviors of the reader’s LED and Beeper indicators.
Appendix B, Standard Defaults references common factory default settings for reader features and options.
Appendix C, Sample Bar Codes offers sample bar codes of several common symbologies.
Appendix D, Keypad includes numeric bar codes to be scanned for certain parameter settings.
Appendix E, Scancode Tables lists control character emulation information for Wedge and USB Keyboard interfaces.
The symbols listed below are used in this manual to notify the reader of key issues or procedures that must be observed when using the reader:
The CAUTION symbol advises you of actions that could damage equipment or property.
Technical Support
Datalogic Website Support
The Datalogic website (www.datalogic.com) is the complete source for technical support and information for Datalogic products. The site offers product support, warranty information, product manuals, product tech notes, software updates, demos, and instructions for returning products for repair.
An excellent source for technical assistance and information is an authorized Datalogic reseller. A reseller is acquainted with specific types of businesses, application software, and computer systems and can provide individualized assistance.
Introduction Technical Support

If you do not have internet or email access, you may contact Datalogic technical support at (541) 349-8283 or check the back cover of your manual for more contact information.
Current versions of the Product Reference Guide (PRG), Quick Reference Guide (QRG), the Datalogic Aladdin™ Configuration application, software/firmware and any additional manuals, instruction sheets and utilities for this product can be downloaded from the website listed on the back cover of this manual. Alternatively, printed copies or product support CDs can be purchased through your Datalogic reseller.
Technical Support Introduction

Introduction Technical Support

Setup
Unpacking
Check carefully to ensure the reader and any accessories ordered are present and undamaged. If any damage occurred during shipment, contact Technical Support on page 2.
KEEP THE PACKAGING. Should the unit ever require service, it should be returned in its original shipping container.
Follow the steps provided in this section to connect and get your reader up and communicating with its host:
The reader kit you ordered to match your interface should provide a compatible cable for your installation. If not, contact Technical Support.
Seat the cable assembly into the reader, aligning both the connector and the cable clip with its opening. To disconnect the cable, insert a paper clip or similar object into the opening on the reader, as shown in Figure 1 on page 6.

Setup Setting Up the Reader
Figure 1. Connecting/Disconnecting the Interface Cable to the Reader
Depending on the model, the reader can communicate using the following interfaces:
RS-232: The reader can communicate with a standard or Wincor-Nixdorf (W-N) RS-232 host.
RS-232 OPOS: This interface is used for OPOS/UPOS/JavaPOS systems.
Keyboard Wedge (KBW) : When connected using this interface, the host interprets scanned data as keystrokes and supports several international keyboards (for the Windows® environment). See "Country Mode" on page 35 for a full listing.
Wand: The Touch 65/90 Pro can be set to use the Wand Emulation interface.
USB: Select to communicate either by USB OEM, USB COM STD, or USB Keyboard interface types by scanning the appropriate interface type bar codes available in this manual. The default interface is USB-KBD (Touch Lite USB and Touch Pro), or RS232-STD (Touch Lite RS232).

Setting Up the Reader Setup
Turn off power to the terminal/PC and connect the reader to the terminal/PC serial port via the RS-232 cable as shown. If the terminal will not support POT (Power Off the Terminal) to supply reader power, use the approved power supply (AC Adapter). Plug the AC Adapter barrel connector into the socket on the RS-232 cable connector and the AC Adapter plug into a standard power outlet.

The Keyboard Wedge cable has a ‘Y’ connection from the reader. Connect the female to the male end from the keyboard and the remaining end at the keyboard port at the terminal/PC.

RS-232 Interface · Keyboard Wedge Interface

USB Connection Connect the reader to a USB port on the terminal/PC using the correct USB cable for the interface type you ordered.

Specific cables are required for connection to different hosts. The connectors illustrated above are examples only. Actual connectors may vary from those illus- trated, but the steps to connect the reader remain the same.
Holder/Hands-Free Stand
The TD1100 Holder can also be used as a hands-free stand. Insert the reader nose-first into the holder, then pass the bar code beneath the stand. Refer to "Configuration Using Bar Codes" starting on page 15 for information about programming the reader for use with the stand.
Figure 2. Hands-Free Stand

Setup Holder/Hands-Free Stand · USB Interface

Upon completing the physical connection between the reader and its host, proceed directly to "Configuring the Interface" on page 9 for information and programming for the interface type the reader is connected to (for example: RS-232, Keyboard Wedge, USB, etc.) and scan the appropriate bar code in tha section to select your system’s correct interface type.
The reader, depending upon the model, will support one of the following sets of host interfaces:
Configuring the Interface
Scan the programming bar code from the following section which selects the appropriate interface type matching the system the reader will be connected to. Next, proceed to the corresponding chapter in this manual (also listed in the table) to configure any desired settings and features associated with that interface.
Unlike some other programming features and options, interface selections require that you scan only one programming bar code label. DO NOT scan an ENTER/EXIT bar code prior to scanning an interface selection bar code.
Some interfaces require the reader to start in the disabled state when powered up. If additional reader configuration is desired while in this state, pull the trig- ger and hold it for five seconds. The reader will change to a state that allows programming with bar codes.
Interface Selection Setup

Table 1. Available Interfaces

a. Download the correct USB Com driver from www.datalogic.com

AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key Encoding
Setup Interface Selection


Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key
Interface Selection Setup

Setup Customizing Configuration Settings
This manual contains feature descriptions and bar codes which allow you to reconfigure your reader. Some programming bar code labels, like "Resetting the Product Configuration to Defaults" on page 14, require only the scan of that single label to enact the change. Most of the programming labels in this manual, however, require the reader to be placed in Programming Mode prior to scanning them. Scan an ENTER/EXIT bar code once to enter Programming Mode. Once the reader is in Programming Mode, you can scan a number of parameter settings before scanning the ENTER/EXIT bar code a second time, which will then accept your changes, exit Programming Mode and return the reader to normal operation.
There are some exceptions to the typical programming sequence described above. Please read the description and setting instructions carefully when configuring each given programmable feature.
Datalogic Aladdin™
Programming can alternatively be performed using the Datalogic Aladdin™ Configuration application which is available for free download from the Datalogic website listed on the back cover of this manual. This multi-platform utility program allows device configuration using a PC. It communicates to the device using a serial or USB cable and can also create configuration bar codes to print.
Datalogic Aladdin™ is a multi-platform utility program providing a quick and user-friendly configuration method via the RS-232/USB-COM interface. Aladdin is available on the CD- ROM provided with your product, and also from the Datalogic website. Aladdin allows you to program the reader by selecting configuration commands through a user-friendly graphical interface running on a PC. These commands are sent to the reader over the selected communication interface, or they can be printed as bar codes to be scanned.
Aladdin also provides the ability to perform a software upgrade for the connected device (see the Datalogic Aladdin™ Help On-Line for more details).

Customizing Configuration Settings Setup
The reader is typically factory-configured with a set of default features standard to the interface type you ordered. See "Interface Selection" on page 9.
Global Interface Features, starting on page 17 provides settings configurable by all interface types. If your installation requires you to further customize your reader, you can select other options through use of the instructions and programming bar codes available in the appropriate section for your interface.
If your installation requires different programming than the standard factory default settings, the following sections of this manual allow configuration of non-interface-specific settings you might require:
Configuration Using Bar Codes: General Features includes programming for scanning, beeper and LED indicators and other such universal settings.
Reading Parameters: Reading Parameters include programming for scanning, beeper and LED indicators and other universal settings.
Symbologies: Includes options concerning the bar code label types (symbologies). These settings allow you to enable/disable symbologies, set label lengths, require check digit, etc.
The software version of the device can be transmitted over the RS-232, Keyboard and USB interfaces by scanning the following label.
RevA · Transmit Software Version

Setup Customizing Configuration Settings
If you aren't sure what programming options are in your reader, or you've changed some options and want to restore the Custom Default Configuration that may have been saved in the reader, scan the Restore Custom Default Configuration bar code below. This will restore the custom configuration for the currently active interface.
Custom defaults are based on the interface type. Configure the reader for the correct interface before scanning this label.
Restore Custom Default Configuration
If you aren't sure what programming options are in your reader, or you've changed some options and want to restore the Factory Configuration, you have two options. You can scan the Restore USA Factory Configuration bar code or the Restore EU Factory Configuration bar code below. Both labels restore the reader configuration to the factory settings including the interface type. The USA label restores Label IDs to those historically used in the USA. The EU label restores Label IDs to those historically used in Europe. The Label ID sets for USA and EU are shown in the Label ID section of this manual.
Scanning either of the “Restore Factory Configuration” commands below will result in the loss of any custom configuration settings for your device.
Restore USA Factory Configuration
Restore EU Factory Configuration
The programming section on the following pages lists the factory default settings for each of the menu commands (indicated by shaded blocks and bold text).

Configuration Using Bar Codes
This and following sections provide programming bar codes to configure your reader by changing the default settings. For details about additional methods of programming, see "Customizing Configuration Settings" on page 12.
You must first enable your reader to read bar codes in order to use this section. If you have not done this, go to Setup, starting on page 5 and complete the appropriate procedure.
Configuration Parameters
Once the reader is set up, you can change the default parameters to meet your application needs. Refer to "Resetting the Product Configuration to Defaults" on page 14 for initial configuration in order to set the default values and select the interface for your application.
The following configuration parameters are divided into logical groups, making it easy to find the desired function based on its reference group.
Symbology-specific parameters: "Symbologies" on page 87 defines options for all symbologies and provides the programming bar codes necessary for configuring these features.
You must first enable your reader to read bar codes in order to use this section. If you have not done this, go to Setup, starting on page 5 and complete the appropriate procedure.

Additional information about many features can be found in the “Refer ences” chapter.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
For more detailed descriptions, programming information and examples for setting selected configuration items, see References, starting on page 251.
Enter/Exit Programming Mode

The following interface features are configurable by all interface types. To set features specific to your interface, turn to that section of this manual:
This option specifies whether the reader will obey or ignore host commands. When set to ignore, the reader will ignore all host commands except for those necessary for:
Host Commands = Obey
Host Commands = Ignore
Enter/Exit Programming Mode

The reader always goes to USB suspend mode (low power consumption) when the connected PC goes to standby mode. This setting enables/disables the ability of USB interfaces to wake up the PC by a trigger pull.
When disabled, a scanner with a USB keyboard interface active will not wake up the PC by trigger pull.
USB Suspend Mode = Disable
USB Suspend Mode = Enable
Enter/Exit Programming Mode


Use the programming bar codes in this chapter if modifications to the standard RS-232 interface settings are necessary to meet your system’s requirements. Additional settings which apply to both the RS-232 and USB interfaces are available in Chapter 3, RS-232/USB-Com Interfaces.
Reference Appendix B, Standard Defaults for a listing of standard factory settings.
Baud rate is the number of bits of data transmitted per second. Set the reader's baud rate to match the baud rate setting of the host device. With an improper baud rate setting, data may not reach the host correctly.


Enter/Exit Programming Mode Baud Rate



This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCII protocol for sending and receiving data.
The scanner cannot support 7-bit-data when parity-none is set.

The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits selected (one or two) depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.


Enter/Exit Programming Mode Parity
This feature specifies parity required for sending and receiving data. A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements.



The data interface consists of an RS-232 port designed to operate either with or without the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). Handshaking Control includes the following options:




The programming bar codes in this chapter allow modifications to the standard RS-232 and USB-Com interfaces.
Reference Appendix B, Standard Defaults for a listing of standard factory settings.
This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. See "Label ID: Pre-loaded Sets" on page 266 for more detailed programming instructions.

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and not
save the entry string. You can then start again at the begin-

Enter/Exit Programming Mode Beep On ASCII BEL
When this parameter is enabled, the reader issues a beep when a character is detected on the RS-232 serial line. is issued to gain a user's attention to an illegal entry or other important event.

This option enables/disables the action of the reader to sound a three beep sequence upon receiving a Not-On-File (NOF) host command.



This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. When configured, the reader and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error.
Options are:

ACK/NAK Protocol = Enable for label transmission and host-

Enter/Exit Programming Mode ACK NAK Options
This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected. See "ACK Character" on page 254 for more detailed programming instructions.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8- bit data is not recognized when the option Data Bits has been set as 7 Data Bits.
$CR2AC
Select ACK Character Setting
NAK Character
This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected. See "NAK Character" on page 255 for more detailed programming instructions.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8- bit data is not recognized when the option Data Bits has been set as 7 Data Bits.
$CR2NA
Select NAK Character Setting

ACK NAK Options Enter/Exit Programming Mode
This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout. See "ACK NAK Timeout Value" on page 256 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select ACK NAK Timeout Value Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 01 ACK NAK Timeout value is 200ms
~

Enter/Exit Programming Mode ACK NAK Options
This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries. See "ACK NAK Retry Count" on page 257 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select ACK NAK Retry Count Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 003 = 3 Retries
~


This feature specifies the method the reader uses to handle receive errors detected while waiting for an ACK character from the host.
Options are:

ACK NAK Error Handling = Process Error as Valid ACK Character

Enter/Exit Programming Mode Indicate Transmission Failure
This option enables/disables the reader’s ability to sound an error beep to indicate a transmission failure while in ACK/NAK mode.

Specifies the value of the RS-232 host command used to disable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected. See "Disable Character" on page 258 for more detailed programming instructions.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8- bit data is not recognized when the option Data Bits has been set as 7 Data Bits.


Enable Character Enter/Exit Programming Mode
Specifies the value of the RS-232 host command used to enable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected. See "Enable Character" on page 259 for more detailed programming instructions.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8- bit data is not recognized when the option Data Bits has been set as 7 Data Bits.
$CR2EC
Select Enable Character Setting

Enter/Exit Programming Mode Enable Character


Use the programming bar codes in this chapter to select options for USB Keyboard and Wedge Interfaces. Reference Appendix B, Standard Defaults for a listing of standard factory settings. Information about control character emulation which applies to keyboard interfaces is listed in Appendix E, Scancode Tables.
This feature specifies the country/language supported by the keyboard.
Only the following interfaces support ALL Country Modes.
All other interfaces support ONLY the following Country Modes: U.S., Belgium, Britain, France, Germany, Italy, Spain, Sweden.

Supports only the interfaces listed in the Country Mode feature description.
Supports only the interfaces listed in the Country Mode fea- ture description.

Enter/Exit Programming Mode Country Mode

Supports only the interfaces listed in the Country Mode feature description.
Supports only the interfaces listed in the Country Mode fea ture description.
Supports only the interfaces listed in the Country Mode fea ture description.
Supports only the interfaces listed in the Country Mode



Supports only the interfaces listed in the Country Mode feature description.
Supports only the interfaces listed in the Country Mode fea ture description.
Supports only the interfaces listed in the Country Mode feature description.
Supports only the interfaces listed in the Country Mode fea ture description.
Supports only the interfaces listed in the Country Mode feature description.

Enter/Exit Programming Mode Caps Lock State
This option specifies the format in which the reader sends character data. This applies to Keyboard Wedge interfaces. This does not apply when an alternate key encoding keyboard is selected.

This option specifies the setting of the Numbers Lock (Numlock) key while in Keyboard Wedge interface. This only applies to alternate key encoding interfaces. It does not apply to USB Keyboard.


Keyboard Numeric Keypad Enter/Exit Programming Mode
This feature specifies if numeric characters will be sent using the standard keys or the numeric keypad.
Keyboard Numeric Keypad = Standard Keys
Keyboard Numeric Keypad = Numeric Keypad

Enter/Exit Programming Mode Keyboard Send Control Characters
This feature is used by the Keyboard Wedge and USB Keyboard interfaces. It specifies how the reader transmits ASCII control characters to the host. Reference Appendix E, Scancode Tables for more information about control characters.
Options are as follows:
Send Ctrl+Key : ASCII characters from 00H to 0x1FH inclusive are transmitted in the format Ctrl+Key. Special keys are available in the range from 81H to A1.
Send Ctrl+Shift+Key : The behavior is the same as above, but control keys are sent in the format Ctrl+Shift+Keys.
Send Special Function Key : Send characters between 00H and 1FH according to the special function key mapping table (see "Microsoft Windows Codepage 1252" on page 318). This is used to send keys that are not in the normal ASCII set. A unique set is provided for each available scancode set.


Wedge Quiet Interval Enter/Exit Programming Mode
This option specifies the amount of time to look for keyboard activity before the reader breaks the keyboard connection in order to transmit data to host. The selectable range for this feature is from 0 to 990ms in 10ms increments. See "Wedge Quiet Interval" on page 260 for more detailed programming instructions.
This feature applies ONLY to the Keyboard Wedge interface.
$CKBQI
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
Select Wedge Quiet Interval Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
DEFAULT 10 = Quiet Interval of 100 ms
~

Enter/Exit Programming Mode Intercharacter Delay
This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. See "Intercharacter Delay" on page 261 for more detailed programming instructions.
This feature applies ONLY to the Keyboard Wedge interface.

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at

Intercode Delay Enter/Exit Programming Mode
Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds. See "Intercode Delay" on page 262 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
DEFAULT 00 = No Wedge Intercode Delay
Set Intercode Delay · ~

Enter/Exit Programming Mode USB Keyboard Speed
This option specifies the USB poll rate for a USB Keyboard.
This feature applies ONLY to the USB Keyboard interface.





Enter/Exit Programming Mode USB Keyboard Speed

Introduction
Feature settings for USB interfaces differ depending upon which host type the reader will be connected with. Use the feature settings in this chapter to specifically configure for the USB- OEM interface. Other USB interfaces are included in the appropriate chapter for their host type.
Reference Appendix B, Standard Defaults for a listing of standard factory settings.

Enter/Exit Programming Mode USB-OEM Device Usage
The USB-OEM protocol allows for the reader to be identified as one of two different types of bar code readers. Depending on what other scanners you may already have connected to a USB- OEM POS, you may need to change this setting to enable all devices to communicate.
Options are:
It may be necessary to switch device usage when connecting two readers/scanners of the same type to a POS system.

This setting provides for an interface specific control mechanism.
Options are:




W AND I DLE S TATE on page 50
L ABEL S YMBOLOGY C ONVERSION on page 52
This chapter provides feature/settings configuration for the Wand Emulation interface.
Reference Appendix B, Standard Defaults for a listing of standard factory settings.
This feature specifies the speed of the Wand output signal per nominal bar or space. Choices are:


This option specifies the polarity of the Wand output signal. Choices are:

Wand Polarity = Quiet Zones & Spaces High, Bars Low
Wand Polarity = Quiet Zones & Spaces Low, Bars High
This feature specifies the level of the Wand output signal when the reader is idle.

Enter/Exit Programming Mode


This option specifies the leading/trailing noise for the Wand interface.


When this feature is enabled for the Wand Emulation interface, all barcode labels are converted to a single symbology. Options are:

Enter/Exit Programming Mode

G LOBAL AIM ID on page 55
L ABEL ID starting on page 56
C HARACTER C ONVERSION on page 66
The features in this chapter can be used to build specific user-defined data into a message string. See "References" starting on page 251 for more detailed instructions on setting these features.

Enter/Exit Programming Mode Global Prefix/Suffix
Up to 20 ASCII characters may be added as a prefix (in a position before the bar code data) and/ or as a suffix (in a position following the bar code data). See "Global Prefix/Suffix" on page 264 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/EXIT bar code again.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT No Global Prefix Global Suffix = 0x0D(CR)
Set Global Prefix · Set Global Suffix · ~


This feature enables/disables addition of AIM IDs for all symbology types.
AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data. See "Global AIM ID" on page 265 for more detailed programming instructions.

If Global AIM ID is disabled, the AIM ID for GS1-128 can be enabled/disabled independently. The AIM ID for GS1-128 is a ]C1, ]C2 or ]C3.
AIM IDs for other symbologies can be enabled/disabled independently as well. Contact Customer Support for assistance.


Enter/Exit Programming Mode Label ID
A Label ID is a customizable code of up to three ASCII characters (each can be one of hex 0x01- 0xFF), used to identify a bar code (symbology) type. It can be appended previous to or following the transmitted bar code data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs as a pre-loaded set (see "Label ID: Pre-loaded Sets" on page 56) or individually per symbology (see "Label ID: Set Individually Per Symbology" on page 57). If you wish to program the reader to always include an industry standard label identifier for ALL symbology types, see the previous feature "Global AIM ID" on page 55.
The reader supports two pre-loaded sets of Label IDs. shows the USA set and the EU set. See "Label ID: Pre-loaded Sets" on page 266 for more information concerning the pre-loaded sets that are provided.
When changing from one Label ID set to another, all other reader configu- ration settings, including the host interface type, will be erased and set to the factory defaults. Any custom configuration or custom defaults will be lost.
$AE
Label ID Pre-loaded Set = USA Set
Label ID Pre-loaded Set = EU Set
$Ae


This feature configures a Label ID individually for a single symbology.
This setting requires the scanning of bar codes from multiple sec- tions. See "Label ID: Set Individually Per Symbology" on page 268 for more detailed programming instructions.
Label ID Control
This option controls whether a Label ID is disabled, or sent as a prefix or suffix for a given symbology type.

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

Enter/Exit Programming Mode Label ID
This option selects the symbology for which a Label ID is to be configured. See "Label ID: Set Individually Per Symbology" on page 268 for full instructions.





Enter/Exit Programming Mode Label ID




Set Interleaved 2 of 5 CIP HR Label ID Character(s)
Set Datalogic 2 of 5 CIP HR Label ID Character(s)

Enter/Exit Programming Mode Label ID





Enter/Exit Programming Mode Set Global Mid Label ID Character(s)
Specifies a mid-label ID that is added for transmission between the labels of a two label pair. The expected string is a maximum of 20 characters. When combining two label pairs into a single label for transmission to the host, this label ID can be added to the data, following the first label and preceding the second label. See "Set Global Mid Label ID Character(s)" on page 270 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
Set Global Mid Label ID Character(s)
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
No Global Mid Label ID
~ · Character(s) 00000000000000000000 00000000000000000000


This feature allows conversion of the case of all alphabetic characters to upper or lower case.
Case conversion affects ONLY scanned bar code data, and does not affect Label ID, Prefix, Suffix, or other appended data.


Enter/Exit Programming Mode Character Conversion
Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done. See "Character Conversion" on page 270 for more detailed programming instructions.
DEFAULT 0xFFFFFFFFFFFFFFFF(N o character conversion)
Configure Character Conversion


Enter/Exit Programming Mode Double Read Timeout
To prevent a double read of the same label, the Double Read Timeout sets the minimum time allowed between reads of labels of the same symbology and data. If the unit reads a label and sees the same label again within the Double Read Timeout, the second read of the label will be ignored. Double Read Timeout does not apply to scan modes that require a trigger pull for each label that is read.





Enter/Exit Programming Mode Label Gone Timeout
This feature sets the time after the last label segment is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55 seconds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a trigger pull for each label that is read. See "Label Gone Timeout" on page 272 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Label Gone Timeout Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 016 = Timeout of 160 ms
~

Power Save Mode Enter/Exit Programming Mode
When this feature is enabled, the reader will enter Power Save Mode (a lower power consumption state) after being idle (no scanner activity) for one second.
RS-232 and USB interfaces ONLY.
A reader having a Scan Mode setting of Object Sense, Stand Mode, Flashing, or Always On will not enter Power Save Mode. (The reader is always internally active when in these modes.)
$CSLEN00
Power Save Mode = Disabled
Power Save Mode = Enabled

Enter/Exit Programming Mode Sleep Mode Timeout
Specifies the timeout value for the reader to enter Sleep Mode (a very low power consumption state).
RS-232 interface ONLY.
A reader having a Scan Mode setting of Object Sense, Stand Mode, Flashing, or Always On will not enter Sleep Mode. (The reader is always internally active when in these modes.)

Sleep Mode Timeout = 1 Minute 30 Seconds (90 Sec-

LED and Beeper Indicators Enter/Exit Programming Mode
Disables or enables the indication (from the Beeper) that the reader is receiving power.
Power On Alert = Disable (No Audible Indication)
Power On Alert = Power-up Beep

Enter/Exit Programming Mode LED and Beeper Indicators
This feature specifies when the reader will provide indication (beep and/or flash its green LED) upon successfully reading a bar code. Choices are:
This option, which uses CTS, is only valid for RS-232 interfaces.

Indicate Good Read = After CTS Goes Inactive, Then
e


Specifies whether the good read beep has a mono or bitonal beep sound.

Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/tone.)


Enter/Exit Programming Mode LED and Beeper Indicators
Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels.



Specifies the duration of a good read beep.


Enter/Exit Programming Mode LED and Beeper Indicators

Controls illumination during a good read beep.
Setting this configuration item to turn off illumination during the beep reduces the peak current drawn by the reader in some scanning modes.


LED and Beeper Indicators Enter/Exit Programming Mode
This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 0.1 to 25.5 seconds in 100ms increments. See "Good Read LED Duration" on page 273 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Good Read LED Duration Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
020 = Good Read LED stays on for 2 seconds.
Indicators are dimmed during sleep.
~

Enter/Exit Programming Mode Scanning Features
See "Scan Mode" on page 274 for more detailed programming instructions.



This feature specifies the time to remain in Trigger Single mode after the trigger is pulled while in Stand Mode.
This timeout is only used when the Scan Mode is configured as Stand Mode.


Enter/Exit Programming Mode Scanning Features

Stand Mode Triggered Timeout = Switch back to Trig-


This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments. See "Scanning Active Time" on page 275 for more detailed programming instructions.

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
Stand Mode Flash
Enables/disables the LED flash when the reader is in Stand Mode.


Enter/Exit Programming Mode Scanning Features
This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. See "Flash On Time" on page 276 for more detailed programming instructions.

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
Flash Off Time
This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. See "Flash Off Time" on page 277 for more detailed programming instructions.

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.


Sets the sensitivity level for stand mode wakeup. Choices are low, medium and high.


Enter/Exit Programming Mode Scanning Features

Introduction
The reader supports the following symbologies (bar code types). Options for each symbology are included in this chapter.
Default settings are indicated at each feature/option with a green arrow. Also reference Appendix B, Standard Defaults for a listing of the most widely used set of standard factory settings. That section also provides space to record any custom settings needed or implemented for your system.

Enter/Exit Programming Mode Disable All Symbologies
Scan this label to disable all symbologies.

This feature is used to control the method of processing coupon labels.
Options are:
To set this feature:



The following options apply to the UPC-A symbology.
When disabled, the reader will not read UPC-A bar codes.

Enable this option to transmit the check character along with UPC-A bar code data.


Enter/Exit Programming Mode UPC-A
Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.

This feature enables/disables transmission of the UPC-A number system character.



This feature specifies the minimum number of consecutive times an in-store label must be decoded before it is accepted as good read.
In-store labels are defined as UPC-A labels with a number-system character of 2 or 4 as well as EAN 8 and EAN 13 labels with a Flag1 character of 2 or an EAN 13 label starting with the three characters '980'.


Enter/Exit Programming Mode UPC-E
The following options apply to the UPC-E symbology.
When disabled, the reader will not read UPC-E bar codes.

Enable this option to transmit the check character along with UPC-E bar code data.



Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.

Expands UPC-E data to the UPC-A data format.


Enter/Exit Programming Mode UPC-E
This feature enables/disables transmission of the UPC-E system number character.

This feature specifies the minimum number of consecutive times a UPC-E label must be decoded before it is accepted as good read.



The following options apply to the EAN 13 (Jan 13) symbology.
When disabled, the reader will not read EAN 13/JAN 13 bar codes.

Enable this option to transmit the check character along with EAN 13 bar code data.


Enter/Exit Programming Mode EAN 13
Enables/disables transmission of an EAN/JAN13 Flag1 character. The Flag 1 character is the first character of the label.

This option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to ISBN labels.



Enables/disables conversion of EAN/JAN13 Bookland labels starting with 977 to ISSN labels.

This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as good read.


Enter/Exit Programming Mode EAN 8
The following options apply to the EAN 8 (Jan 8) symbology.
When disabled, the reader will not read EAN 8/JAN 8 bar codes.

Enable this option to transmit the check character along with EAN 8 bar code data.



Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13.

Enables/disables the ability of the reader to find an EAN/JAN8 guard pattern in cases where the EAN/JAN8 margin makes the guard look like a character.


Enter/Exit Programming Mode EAN 8
Enables/disables the ability to insert a guard into an otherwise full-strike EAN 8 segment.

Enables/disables the ability of the reader to substitute guard pattern for even parity 6 when an EAN/JAN8 label is presented.



Specifies the minimum number of characters necessary in an EAN/JAN8 label segment in order for the reader to accept the segment for decoding.


Enter/Exit Programming Mode EAN 8
EAN 8 Minimum Segment Length Block — cont.



This feature specifies the minimum number of consecutive times an EAN 8 (Jan 8) label must be decoded before it is accepted as good read.


Enter/Exit Programming Mode EAN 8
Enables/disables the ability to stitch exact EAN 8 label halves with no overlapping characters.
The label halves being stitched together to assemble a com- plete label must have the structure GddddC and CddddG.

Enables/disables the ability to stitch EAN 8 label halves together which may have differing characters in them.
The label structure must be GddddCd... and ..dCddddG. The characters dCd must match between the two segments.



When disabled, the reader will not read EAN two label bar codes.

This feature enables/disables transmission of an EAN two label pair as one label. The label type for EAN two label pairs is EAN 13.


Enter/Exit Programming Mode EAN Two Label
This feature specifies the minimum number of consecutive times an EAN two label bar code must be decoded before it is accepted as good read.



This section provides configuration settings for UPC-A, UPC-E, EAN 13 and EAN 8 symbologies, and affects all of these unless otherwise marked for each feature description.
Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.


Enter/Exit Programming Mode UPC/EAN Global Settings
When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the reader read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
UPC/EAN Correlation = Disable
UPC/EAN Correlation = Enable


This feature enables/disables calculation and verification of price/weight check digits.

Options are

Enter/Exit Programming Mode UPC/EAN Global Settings
This feature specifies the minimum number of consecutive times a UPC-A label must be decoded before it is accepted as good read.



Enables/disables the ability to insert either a missing leading or trailing guard on an otherwise complete UPC-A/EAN-13 segment.
The segment must have the structure GddddddCdddddd or ddddddCddddddG.

Enables/disables the ability to stitch exact UPC-A/EAN 13 label halves with no overlapping characters.
The label halves being stitched together to assemble a com- plete label must have the structure GddddddC and CddddddG.


Enter/Exit Programming Mode UPC/EAN Global Settings
Enables/disables the ability to stitch two UPC-A/EAN 13 label halves together that may have differing characters in them.
The label half structures must have the structure GddddddC and CddddddG. The characters dCd must match between the two segments.



Specifies the minimum number of characters necessary in an UPC/EAN/JAN label segment in order for the reader to accept the segment for decoding.


Enter/Exit Programming Mode UPC/EAN Global Settings
UPC/EAN Minimum Segment Length — cont.



The following features apply to optional add-ons.
Contact Customer Support for advanced programming of optional and conditional add-ons.
Optional Add-ons
The reader can be enabled to optionally read the following add-ons (supplementals):
If a UPC/EAN base label and a an add-on are both decoded, the reader will transmit the base label and add-on. If a UPC/ EAN base label is decoded without an add-on, the base label will be transmitted without an add-on.
Conditional add-on settings (if enabled) are considered by the reader before optional add-on settings.


Enter/Exit Programming Mode Add-Ons
Optional Add-ons — cont.



This option sets the time the reader will look for an add-on when an add-on fragment has been seen and optional add-ons are enabled.


Enter/Exit Programming Mode Add-Ons
Optional Add-On Timer — cont.



This feature specifies the minimum number of times a P2 add-on must be read before it is marked as valid and then combined with a base label.


Enter/Exit Programming Mode Add-Ons
This feature specifies the minimum number of times a P5 add-on must be read before it is marked as valid and then combined with a base label.



This feature specifies the minimum number of times an GS1-128 add-on must be read before it is marked as valid and then combined with a base label.


Enter/Exit Programming Mode GS1 DataBarTM Omnidirectional
The following options apply to the GS1 DataBar Omnidirectional (formerly RSS-14) symbology.
When disabled, the reader will not read GS1 DataBar Omnidirectional bar codes.

When enabled, GS1 DataBar Omnidirectional bar codes will be translated to the GS1-128 label data format.



This feature specifies the minimum number of consecutive times a GS1 DataBar Omnidirectional label must be decoded before it is accepted as good read.


Enter/Exit Programming Mode GS1 DataBarTM Expanded
The following options apply to the GS1 DataBar Expanded (formerly RSS Expanded) symbology.
When disabled, the reader will not read GS1 DataBar Expanded bar codes.

When enabled, GS1 DataBar Expanded bar codes will be translated to the GS1-128 label data format.



This feature specifies the minimum number of consecutive times a GS1 DataBar Expanded label must be decoded before it is accepted as good read.


Enter/Exit Programming Mode GS1 DataBarTM Expanded
This feature specifies either variable length decoding or fixed length decoding for the GS1 DataBar Expanded symbology.
Variable Length: For variable-length decoding, a minimum length may be set.
Fixed Length: For fixed-length decoding, two different lengths may be set.

This feature specifies one of the bar code lengths for GS1 DataBar Expanded Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.
The length can be set from 1 to 74 characters. See "Set Length 1" on page 278 for more detailed programming instructions.

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

GS1 DataBarTM Expanded Enter/Exit Programming Mode
This feature specifies one of the bar code lengths for GS1 DataBar Expanded Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.
The length can be set from 1 to 74 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select GS1 DataBar Expanded Set Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 74 = Length 2 is 74 Characters
~

Enter/Exit Programming Mode GS1 DataBarTM Limited
The following options apply to the GS1 DataBar Limited (formerly RSS Limited) symbology.
When disabled, the reader will not read GS1 DataBar Limited bar codes.

When enabled, GS1 DataBar Limited bar codes will be translated to the GS1-128 label data format.



This feature specifies the minimum number of consecutive times a GS1 DataBar Limited label must be decoded before it is accepted as good read.


Enter/Exit Programming Mode Code 39
The following options apply to the Code 39 symbology.
When disabled, the reader will not read Code 39 bar codes.
Code 39 = Disable
Code 39 = Enable


Enable this option to enable/disable calculation and verification of an optional Code 39 check character. When disabled, any check character in the label is treated as a data character.

Code 39 Check Character Calculation = Calculate Mod 7
Code 39 Check Character Calculation = Enable Italian Post

Enter/Exit Programming Mode Code 39
Enable this option to transmit the check character along with Code 39 bar code data.

Enable this option to enable/disable transmission of Code 39 start and stop characters.



In Code 39 decoding, this enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters.


Enter/Exit Programming Mode Code 39
This feature specifies the number of quiet zones for Code 39 labels. Quiet zones are blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label.

Code 39 Quiet Zones = Quiet Zone on one side
Code 39 Quiet Zones = Quiet Zones on two sides
Code 39 Quiet Zones = Virtual Quiet Zones on two sides
Code 39 Quiet Zones = Small Quiet Zones on two sides


This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read.


Enter/Exit Programming Mode Code 39
Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.


Code 39 Enter/Exit Programming Mode
This feature specifies either variable length decoding or fixed length decoding for the Code 39 symbology.
Variable Length: For variable length decoding, a minimum and maximum length may be set.
Fixed Length: For fixed length decoding, two different lengths may be set.
Code 39 Length Control = Variable Length
Code 39 Length Control = Fixed Length

Enter/Exit Programming Mode Code 39
This feature specifies one of the bar code lengths for Code 39 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.
The length can be set from 0 to 50 characters. See "Set Length 1" on page 278 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Code 39 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 02 = Length 1 is 2 Characters
~

Code 39 Enter/Exit Programming Mode
This feature specifies one of the bar code lengths for Code 39 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Code 39 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 50 = Length 2 is 50 Characters
~

Enter/Exit Programming Mode Code 39
This feature specifies the ratio between an intercharacter space and module for Code 39 labels.



Code 39 Interdigit Ratio — cont.


Enter/Exit Programming Mode Code 39
When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the reader read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.

This option enables/disables stitching for Code 39 labels. When parts of a Code 39 bar code are presented to the reader with this feature enabled, the bar code parts will be assembled by the reader’s software, and the data will be decoded if all bar code proofing requirements are met.
This feature is available only on the TD1130 model.



The following options apply to the Code 32 symbology.
When disabled, the reader will not read Code 32 bar codes.

The following features are set for Code 32 by using these Code 39 settings:
"Code 39 Quiet Zones" on page 134 "Code 39 Minimum Reads" on page 135 "Code 39 Decoding Level" on page 136 "Code 39 Interdigit Ratio" on page 140 "Code 39 Character Correlation" on page 142 "Code 39 Stitching" on page 142

Enter/Exit Programming Mode Code 32 (Italian Pharmaceutical)
Enable this option to transmit the check character along with Code 32 bar code data.

This option enables/disable transmission of Code 32 start and stop characters.



The following options apply to the Code 39 CIP symbology.
Enables/Disables ability of the reader to decode Code 39 CIP labels.

The following options apply to the Code 128 symbology.
When disabled, the reader will not read Code 128 bar codes.


Enter/Exit Programming Mode Code 128
This feature enables/disables expansion of Code 128 labels to Code 39 labels. When enabled, the label identifier for a Code 128 label shall be set to Code 39 and all Code 39 formatting control shall be applied to the label.

Enable this option to transmit the check character along with Code 128 bar code data.



Enables/disables transmission of Code128 function characters 1, 2, 3, and 4.
It is recommended that this setting be disabled for all interfaces except Wand Emulation.

Enables/disables the transmission of “Sub-Code exchange” characters (NOT transmitted by standard decoding).


Enter/Exit Programming Mode Code 128
This feature specifies the number of quiet zones for Code 128 labels. Quiet zones are blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label.

Code 128 Quiet Zones = Quiet Zone on one side
Code 128 Quiet Zones = Quiet Zones on two sides
Code 128 Quiet Zones = Virtual Quiet Zones on two


This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read.


Enter/Exit Programming Mode Code 128
Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.


Code 128 Enter/Exit Programming Mode
This feature specifies either variable length decoding or fixed length decoding for the Code 128 symbology.
Variable Length: For variable length decoding, a minimum and maximum length may be set.
Fixed Length: For fixed length decoding, two different lengths may be set.
Code 128 Length Control = Variable Length
Code 128 Length Control = Fixed Length

Enter/Exit Programming Mode Code 128
This feature specifies one of the bar code lengths for Code 128 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.
The length can be set from 1 to 80 characters. See "Set Length 1" on page 278 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Code 128 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 01 = Length 1 is 1 Character
~

Code 128 Enter/Exit Programming Mode
This feature specifies one of the bar code lengths for Code 128 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.
The length can be set from 1 to 80 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Code 128 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 80 = Length 2 is 80 Characters
~

Enter/Exit Programming Mode Code 128
When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the reader read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.

This option enables/disables stitching for Code 128 labels. When parts of a Code 128 bar code are presented to the reader with this feature enabled, the bar code parts will be assembled by the reader’s software, and the data will be decoded if all bar code proofing requirements are met.
This feature is available only on the TD1130 model.



The following options apply to the GS1-128 symbology. (Also known as USS-128, GTIN-128, UCC-128.)
This option enables/disables the ability of the reader to translate GS1-128 labels to the GS1-128 data format. Options are:


Enter/Exit Programming Mode Interleaved 2 of 5 (I 2 of 5)
The following options apply to the I 2 of 5 symbology.
When disabled, the reader will not read I 2 of 5 bar codes.
I 2 of 5 = Disable
I 2 of 5 = Enable


Interleaved 2 of 5 (I 2 of 5) Enter/Exit Programming Mode
This option enables/disables calculation and verification of an optional I 2 of 5 check character.

I 2 of 5 Check Char Calc = Disable
I 2 of 5 Check Char Calc = Check Standard
I 2 of 5 Check Char Calc = Check German Parcel
I 2 of 5 Check Char Calc = Check DHL
I 2 of 5 Check Char Calc = Check Daimler Chrysler
I 2 of 5 Check Char Calc = Check Bosch
I 2 of 5 Check Character Calculation = Check Italian Post
When disabled, any check character in label is treated as a data character.

Enter/Exit Programming Mode Interleaved 2 of 5 (I 2 of 5)
Enable this option to transmit the check character along with I 2 of 5 bar code data.
This feature is valid only when I 2 of 5 Check Character Calculation is enabled.

I 2 of 5 Check Character Transmission = Don’t Send
I 2 of 5 Check Character Transmission = Send


Interleaved 2 of 5 (I 2 of 5) Enter/Exit Programming Mode
This feature specifies the minimum number of consecutive times an I 2 of 5 label must be decoded before it is accepted as good read.


Enter/Exit Programming Mode Interleaved 2 of 5 (I 2 of 5)
This configuration item applies to Interleaved 2 of 5, Datalogic 2 of 5 and Standard 2 of 5.
Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.


Interleaved 2 of 5 (I 2 of 5) Enter/Exit Programming Mode
This feature specifies either variable length decoding or fixed length decoding for the I 2 of 5 symbology.
Variable Length: For variable length decoding, a minimum and maximum length may be set.
Fixed Length: For fixed length decoding, two different lengths may be set.
I 2 of 5 Length Control = Variable Length
I 2 of 5 Length Control = Fixed Length

Enter/Exit Programming Mode Interleaved 2 of 5 (I 2 of 5)
This feature specifies one of the bar code lengths for I 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. The length includes the bar code’s check and data characters.
The length can be set from 2 to 50 characters in increments of two. See "Set Length 1" on page 278 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select I 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 06 = Length 1 is 6 Characters
~

Interleaved 2 of 5 (I 2 of 5) Enter/Exit Programming Mode
This feature specifies one of the bar code lengths for I 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the bar code’s check and data characters.
The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select I 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 50 = Length 2 is 50 Characters
~

Enter/Exit Programming Mode Interleaved 2 of 5 (I 2 of 5)
When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the reader read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.

Enables/disables ZERO-Digit decoding. This character does not represent any cipher. It allows encoding of an odd number of ciphers with Interleaved 2 of 5. It must be enabled to decode Code 2 of 5 CIP/HR.



Interleaved 2 of 5 CIP HR Enter/Exit Programming Mode
This option enables/disables stitching for I 2 of 5 labels. When parts of a I 2 of 5 bar code are presented to the reader with this feature enabled, the bar code parts will be assembled by the reader’s software, and the data will be decoded if all bar code proofing requirements are met.
This feature is available only on the TD1130 model.

The following options apply to the Interleaved 2 of 5 CIP HR symbology.
Enables/Disables ability of reader to decode Interleaved 2 of 5 CIP HR labels.


Enter/Exit Programming Mode Datalogic 2 of 5
The following options apply to the Datalogic 2 of 5 symbology.
When disabled, the reader will not read Datalogic 2 of 5 bar codes.

This option enables/disables calculation and verification of an optional Datalogic 2 of 5 check character.

Datalogic 2 of 5 Check Character Calculation = Disable
Datalogic 2 of 5 Check Character Calculation = Enable


This option enables/disables transmission of an optional Datalogic 2 of 5 character.

Datalogic 2 of 5 Check Character Transmission = Don’t
Datalogic 2 of 5 Check Character Transmission = Send
This feature specifies the minimum number of consecutive times an Datalogic 2 of 5 label must be decoded before it is accepted as good read.


Enter/Exit Programming Mode Datalogic 2 of 5
The Datalogic 2 of 5 Decoding Level feature is set using "I 2 of 5 Decoding Level" on page 160.
Datalogic 2 of 5 Length Control
This feature specifies either variable length decoding or fixed length decoding for the Datalogic 2 of 5 symbology.
Variable Length: For variable length decoding, a minimum and maximum length may be set.
Fixed Length: For fixed length decoding, two different lengths may be set.

Datalogic 2 of 5 Length Control = Variable Length
Datalogic 2 of 5 Length Control = Fixed Length

Datalogic 2 of 5 Enter/Exit Programming Mode
This feature specifies one of the bar code lengths for Datalogic 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. The length includes the bar code’s data characters only.
The length can be set from 2 to 50 characters in increments of two. See "Set Length 1" on page 278 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Datalogic 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 06 = Length 1 is 6 Characters
~

Enter/Exit Programming Mode Datalogic 2 of 5
This feature specifies one of the bar code lengths for Datalogic 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the bar code’s data characters only.
The length can be set from 2 to 50 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Datalogic 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 50 = Length 2 is 50 Characters
~


This feature specifies the maximum ratio between intercharacter space and module for Datalogic 2 of 5.


Enter/Exit Programming Mode Datalogic 2 of 5
Datalogic 2 of 5 Interdigit Maximum Ratio — cont.



When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the reader read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.

This option enables/disables stitching for Datalogic 2 of 5 labels. When parts of a Datalogic 2 of 5 bar code are presented to the reader with this feature enabled, the bar code parts will be assembled by the reader’s software, and the data will be decoded if all bar code proofing requirements are met.
This feature is available only on the TD1130 model.


Enter/Exit Programming Mode Codabar
The following options apply to the Codabar symbology.
When disabled, the reader will not read Codabar bar codes.

Enable this option to enables/disables calculation and verification of an optional Codabar check character. When disabled, any check characters in the label are treated as data characters.



Enable this option to transmit the check character along with Codabar bar code data.
This feature is valid only when Codabar Check Character Calculation is enabled.

Enable this option to enable/disable transmission of Codabar start and stop characters.


Enter/Exit Programming Mode Codabar
This option specifies the format of transmitted Codabar start/stop characters.


Codabar Enter/Exit Programming Mode
When enabled, this option requires that start and stop characters match.
Codabar Start/Stop Character Match = Don’t Require
Codabar Start/Stop Character Match = Require Match
Match

Enter/Exit Programming Mode Codabar
This feature specifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label.

Codabar Quiet Zones = Quiet Zone on one side
Codabar Quiet Zones = Quiet Zones on two sides
Codabar Quiet Zones = Virtual Quiet Zones on two sides
Codabar Quiet Zones = Small Quiet Zones on two sides


This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good read.


Enter/Exit Programming Mode Codabar
Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.


Codabar Enter/Exit Programming Mode
This feature specifies either variable length decoding or fixed length decoding for the Codabar symbology.
Variable Length: For variable length decoding, a minimum and maximum length may be set.
Fixed Length: For fixed length decoding, two different lengths may be set.
Codabar Length Control = Variable Length
Codabar Length Control = Fixed Length

Enter/Exit Programming Mode Codabar
This feature specifies one of the bar code lengths for Codabar Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s start, stop, check and data characters. The length must include at least one data character.
The length can be set from 3 to 50 characters. See "Set Length 1" on page 278 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Codabar Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 03 = Length 1 is 3 Characters
~

Codabar Enter/Exit Programming Mode
This feature specifies one of the bar code lengths for Codabar Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the bar code’s start, stop, check and data characters. The length must include at least one data character.
The length can be set from 3 to 50 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Codabar Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 50 = Length 2 is 50 Characters
~

Enter/Exit Programming Mode Codabar
This feature specifies the maximum ratio between an intercharacter space and module for Codabar labels.



Codabar Interdigit Ratio — cont.


Enter/Exit Programming Mode Codabar
When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the reader read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.

This option enables/disables stitching for Codabar labels. When parts of a Codabar bar code are presented to the reader with this feature enabled, the bar code parts will be assembled by the reader’s software, and the data will be decoded if all bar code proofing requirements are met.
This feature is available only on the TD1130 model.



The following options apply to the ABC Codabar symbology.
Enables/Disables ability of reader to decode ABC Codabar labels.

Specifies the concatenation mode between Static and Dynamic.


Enter/Exit Programming Mode ABC Codabar
This parameter specifies the timeout in 10-millisecond ticks used by the ABC Codabar Dynamic Concatenation Mode. The timeout can be set within a range of 05 to 255 in 10ms increments. A setting of zero specifies no delay.

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
Forces labels starting or ending with D to be concatenated.


Code 11 Enter/Exit Programming Mode
The following options apply to the Code 11 symbology.
When disabled, the reader will not read Code 11 bar codes.
Code 11 = Disable
Code 11 = Enable

Enter/Exit Programming Mode Code 11
This option enables/disables calculation and verification of optional Code 11 check character.

Code 11 Check Character Calculation = Check C and K
This feature enables/disables transmission of an optional Code 11 check character.



This feature specifies the minimum number of consecutive times a Code 11 label must be decoded before it is accepted as good read.


Enter/Exit Programming Mode Code 11
This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology.
Variable Length: For variable length decoding, a minimum and maximum length may be set.
Fixed Length: For fixed length decoding, two different lengths may be set.

This feature specifies one of the bar code lengths for Code 11 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s check and data characters.
The length can be set from 2 to 50 characters. See "Set Length 1" on page 278 for more detailed programming instructions.

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

Code 11 Enter/Exit Programming Mode
This feature specifies one of the bar code lengths for Code 11 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check and data characters.
The length can be set from 2 to 50 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Code 11 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 50 = Length 2 is 50 Characters
~

Enter/Exit Programming Mode Code 11
This feature specifies the ratio between an intercharacter space and module for Code 11 labels.



Code 11 Interdigit Ratio — cont.


Enter/Exit Programming Mode Code 11
Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.



When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the reader read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.

This option enables/disables stitching for Code 11 labels. When parts of a Code 11 bar code are presented to the reader with this feature enabled, the bar code parts will be assembled by the reader’s software, and the data will be decoded if all bar code proofing requirements are met.
This feature is available only on the TD1130 model.


Enter/Exit Programming Mode Standard 2 of 5
The following options apply to the Standard 2 of 5 symbology.
When disabled, the reader will not read Standard 2 of 5 bar codes.

This option enables/disables calculation and verification of an optional Standard 2 of 5 check character.

Standard 2 of 5 Check Character Calculation = Disable
Standard 2 of 5 Check Character Calculation = Enable


This feature enables/disables transmission of an optional Standard 2 of 5 check character.

Standard 2 of 5 Check Character Transmission = Don’t
Standard 2 of 5 Check Character Transmission = Send
This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as good read.


Enter/Exit Programming Mode Standard 2 of 5
The Standard 2 of 5 Decoding Level feature is set using "I 2 of 5 Decoding Level" on page 160.
Standard 2 of 5 Length Control
This feature specifies either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology.
Variable Length: For variable length decoding, a minimum and maximum length may be set.
Fixed Length: For fixed length decoding, two different lengths may be set.

Standard 2 of 5 Length Control = Variable Length
Standard 2 of 5 Length Control = Fixed Length

Standard 2 of 5 Enter/Exit Programming Mode
This feature specifies one of the bar code lengths for Standard 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s check and data characters.
The length can be set from 1 to 50 characters. See "Set Length 1" on page 278 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Standard 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 08 = Length 1 is 8 Characters
~

Enter/Exit Programming Mode Standard 2 of 5
This feature specifies one of the bar code lengths for Standard 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check and data characters.
The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Standard 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 50 = Length 2 is 50 Characters
~


When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the reader read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.

This option enables/disables stitching for Standard 2 of 5 labels. When parts of a Standard 2 of 5 bar code are presented to the reader with this feature enabled, the bar code parts will be assembled by the reader’s software, and the data will be decoded if all bar code proofing requirements are met.
This feature is available only on the TD1130 model.


Enter/Exit Programming Mode Industrial 2 of 5
The following options apply to the Industrial 2 of 5 symbology.
Enables/Disables ability of reader to decode Industrial 2 of 5 labels.

Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.

Industrial 2 of 5 Check Character Calculation = Disable
Industrial 2 of 5 Check Character Calculation = Enable


Enables/disables transmission of an Industrial 2 of 5 check character.

Industrial 2 of 5 Check Character Transmission = Disable
Industrial 2 of 5 Check Character Transmission = Enable
This feature specifies either variable length decoding or fixed length decoding for the Industrial 2 of 5 symbology.
Variable Length: For variable length decoding, a minimum and maximum length may be set.
Fixed Length: For fixed length decoding, two different lengths may be set.

Industrial 2 of 5 Length Control = Variable Length

Enter/Exit Programming Mode Industrial 2 of 5
This feature specifies one of the bar code lengths for Industrial 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.
The length can be set from 1 to 50 characters. See "Set Length 1" on page 278 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Industrial 2 of 5 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 01 = Length 1 is 1 Character
~

Industrial 2 of 5 Enter/Exit Programming Mode
This feature specifies one of the bar code lengths for Industrial 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Industrial 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 50 = Length 2 is 50 Characters
~

Enter/Exit Programming Mode Industrial 2 of 5
This feature specifies the minimum number of consecutive times an Industrial 2 of 5 label must be decoded before it is accepted as good read.



Enables/disables fixed length stitching for Industrial 2 of 5.
This feature is available only on the TD1130 model.

Enable/disables character correlation for Industrial 2 of 5.


Enter/Exit Programming Mode IATA
The following options apply to the IATA symbology.
Enables/Disables the ability of the reader to decode IATA labels.

Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.



The following options apply to the ISBT 128 symbology.
Enables/disables ISBT128 concatenation of 2 labels.

Specifies the concatenation mode between Static and Dynamic.
This option is only valid when ISBT 128 Concatenation is enabled (see page 211).


Enter/Exit Programming Mode ISBT 128
Specifies the timeout used by the ISBT 128 Dynamic Concatenation Mode.



When enabled, this feature forces all ISBT 128 labels to be concatenated.
This option is only valid when ISBT 128 Concatenation is enabled. (see page 211).

Use the Datalogic Aladdin configuration application or Contact Customer Support to set up pairs of label types for concatenation.

Enter/Exit Programming Mode MSI
The following options apply to the MSI symbology.
Enables/Disables ability of reader to decode MSI labels.

Enables/Disables calculation and verification of an optional MSI check character.



Enables/disables transmission of an MSI check character.

This feature specifies either variable length decoding or fixed length decoding for the MSI symbology.
Variable Length: For variable length decoding, a minimum and maximum length may be set.
Fixed Length: For fixed length decoding, two different lengths may be set.


Enter/Exit Programming Mode MSI
This feature specifies one of the bar code lengths for MSI Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.
The length can be set from 01 to 50 characters. See "Set Length 1" on page 278 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select MSI Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 01 = Length 1 is 1 Character
~

MSI Enter/Exit Programming Mode
This feature specifies one of the bar code lengths for MSI Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select MSI Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 50 = Length 2 is 50 Characters
~

Enter/Exit Programming Mode MSI
This feature specifies the minimum number of consecutive times an MSI label must be decoded before it is accepted as good read.



Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.


Enter/Exit Programming Mode Code 93
The following options apply to the Code 93 symbology.
Enables/Disables ability of reader to decode Code 93 labels.

Enables/disables calculation and verification of an optional Code 93 check character.

Code 93 Check Character Calculation = Enable Check C
Code 93 Check Character Calculation = Enable Check K


Enables/disables transmission of an optional Code 93 check character.

This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology.
Variable Length: For variable length decoding, a minimum and maximum length may be set.
Fixed Length: For fixed length decoding, two different lengths may be set.


Enter/Exit Programming Mode Code 93
This feature specifies one of the bar code lengths for Code 93 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.
The length can be set from 01 to 50 characters. See "Set Length 1" on page 278 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Code 93 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 01 = Length 1 is 1 Character
~

Code 93 Enter/Exit Programming Mode
This feature specifies one of the bar code lengths for Code 93 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Code 93 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 50 = Length 2 is 50 Characters
~

Enter/Exit Programming Mode Code 93
This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read.



Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.


Enter/Exit Programming Mode Code 93
Enables/disables fixed length stitching for Code 93.
This feature is available only on the TD1130 model.

Code 93 Quiet Zones = Quiet Zone on one side
Code 93 Quiet Zones = Quiet Zones on two sides
Code 93 Quiet Zones = Virtual Quiet Zones on two sides


Disable/enable fixed or variable length stitching for Code 93.
This feature is available only on the TD1130 model.

Enables/disables Character Correlation for Code 93.


Enter/Exit Programming Mode Codablock F
The following options apply to the Codablock F symbology.
Enables/Disables the ability of the reader to decode Codablock F labels.

Enables/Disables the Codablock F EAN subtype (code with FNC1 in the first position).



Specifies if Check Digit calculation algorithm is AIM compliant or not.

This feature specifies either variable length decoding or fixed length decoding for the Codablock F symbology.
Variable Length: For variable length decoding, a minimum and maximum length may be set.
Fixed Length: For fixed length decoding, two different lengths may be set.


Enter/Exit Programming Mode Codablock F
This feature specifies one of the bar code lengths for Codablock F Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.
The length can be set from 003 to 255 characters. See "Set Length 1" on page 278 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Codablock F Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 003 = Length 1 is 3 Characters
~

Codablock F Enter/Exit Programming Mode
This feature specifies one of the bar code lengths for Codablock F Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.
The length can be set from 3 to 255 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select Codablock F Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 100 = Length 2 is 100 Characters
~

Enter/Exit Programming Mode Code 4
The following options apply to the Code 4 symbology.
Enables/Disables ability of reader to decode Code 4 labels.

This feature enables/disables transmission of an optional Code 4 check character.



This feature enables/disables the conversion of hexadecimal label data to decimal label data.

The following options apply to the Code 5 symbology.
Enables/Disables ability of reader to decode Code 5 labels.


Enter/Exit Programming Mode Code 5
This feature enables/disables transmission of an optional Code 5 check character.

This feature enables/disables the conversion of hexadecimal label data to decimal label data.



Code 4 and Code 5 Common Configuration Items Enter/Exit Programming Mode
The following options apply to both Code 4 and Code 5 symbologies.
Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.
This configuration item applies to Code 4 and Code 5.

Code 4 and Code 5 Decoding Level = 1
Code 4 and Code 5 Decoding Level = 2
Code 4 and Code 5 Decoding Level = 3
Code 4 and Code 5 Decoding Level = 4
Code 4 and Code 5 Decoding Level = 5

Enter/Exit Programming Mode Code 4 and Code 5 Common Configuration Items
This feature specifies the minimum number of consecutive times a Code 4 or Code 5 label must be decoded before it is accepted as good read.

Code 4 or Code 5 Minimum Reads = 1
Code 4 or Code 5 Minimum Reads = 2
Code 4 or Code 5 Minimum Reads = 3
Code 4 or Code 5 Minimum Reads = 4


The following options apply to the Follett 2 of 5 symbology.
Enables/Disables ability of reader to decode Follett 2 of 5 labels.

The following options apply to the BC412 symbology.
Enables/Disables ability of reader to decode BC412 labels.


Enter/Exit Programming Mode BC412
Enable this option to enable/disable calculation and verification of an optional BC412 check character. When disabled, any check character in the label is treated as a data character.

This feature specifies the minimum number of consecutive times a BC412 label must be decoded before it is accepted as good read.



Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.


Enter/Exit Programming Mode BC412
This feature specifies either variable length decoding or fixed length decoding for the BC412 symbology.
Variable Length: For variable length decoding, a minimum and maximum length may be set.
Fixed Length: For fixed length decoding, two different lengths may be set.

This feature specifies one of the bar code lengths for BC412 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.
The length can be set from 0 to 50 characters. See "Set Length 1" on page 278 for more detailed programming instructions.

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

BC412 Enter/Exit Programming Mode
This feature specifies one of the bar code lengths for BC412 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.
To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.
Select BC412 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.
DEFAULT 50 = Length 2 is 50 Characters
~

Enter/Exit Programming Mode Plessey
The following options apply to the Plessey symbology.
Enables/Disables ability of reader to decode Plessey labels.



Enables/Disables calculation and verification of an optional Plessey check character.

Plessey Check Character Calculation = Enable Plessey std. check char. verification
Plessey Check Character Calculation = Enable Plessey std. and Anker check char verification

Enter/Exit Programming Mode Plessey
Enables/disables transmission of an MSI check character.

This feature specifies either variable length decoding or fixed length decoding for the Plessey symbology.
Variable Length. For variable length decoding, a minimum and maximum length may be set.
Fixed Length. For fixed length decoding, two different lengths may be set.


Plessey Enter/Exit Programming Mode
This feature specifies one of the barcode lengths for Plessey Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50 characters.
Table 2 provides some examples for setting Length 1. See "Set Length 1" on page 278 for detailed instructions on setting this feature.
Table 2. Plessey Length 1 Setting Examples
1 Desired Setting 01 Character 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT Plessey LENGTH 1 SETTING
4 Scan Two Characters From
Appendix D, Keypad ‘0’ and ‘1’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Plessey Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
DEFAULT 01 = Length 1 is 1 Character

Enter/Exit Programming Mode Plessey
This feature specifies one of the barcode lengths for Plessey Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
Table 3 provides examples for setting Length 2. See "Set Length 2" on page 280 for detailed instructions on setting this feature.
Table 3. Plessey Length 2 Setting Examples
1 Desired Setting 00 (Ignore This Length) 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT PLESSEY LENGTH 2 SETTING
4 Scan Two Characters From
Appendix D, Keypad ‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Plessey Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
DEFAULT 50 = Length 2 is 50 Characters


This feature specifies the minimum number of consecutive times a Plessey label must be decoded before it is accepted as good read.


Enter/Exit Programming Mode Plessey
Specifies the decoding level for Plessey. Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more information on this feature.



Enables/disables fixed length stitching for Plessey.

Enables/disables Character Correlation for Plessey.




Baud rate is the number of bits of data transmitted per second. Set the reader's baud rate to match the baud rate setting of the host device. With an improper baud rate setting, data may not reach the host correctly.
The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits selected (one or two) depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.
This feature specifies parity required for sending and receiving data. A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements.
The data interface consists of an RS-232 port designed to operate either with or without the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). Handshaking Control includes the following options:
References RS-232 Parameters

This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay.
To set the delay:
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
This completes the procedure. See the following table for examples of how to set this feature.
Table 4. Intercharacter Delay Setting Examples
1 Desired Setting 50ms 150ms 600ms 850ms
2 Divide by 10 (pad with leading
zeroes to yield two-digits) 05 15 60 85
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT INTERCHARACTER DELAY SETTING
5 Scan Two Characters From
Appendix D, Keypad ‘0’ and ‘5’ ‘5’ and ‘0’ ‘6’ and ‘0’ ‘8’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE
RS-232 Parameters References

This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. When configured, the reader and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error.
Options are:
This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host com- mands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits.
See the table below for examples of how to set this feature.
Table 5. ACK Character Setting Examples
1 Desired Character/Value ACK $ @ >
2 Hex equivalent from ASCII Chart 0x06 0x24 0x40 0x3E
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT ACK CHARACTER SETTING
5 Scan Two Characters from
Appendix D, Keypad ‘0’ and ‘6’ ‘2’ and ‘4’ ‘4’ and ‘0’ ‘3’ AND ‘E’
6 Scan ENTER/EXIT PROGRAMMING MODE
References RS-232 Parameters

This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8- bit data is not recognized when the option Data Bits has been set as 7 Data Bits.
To set this feature:
This completes the procedure. See the table below for examples of how to set this feature.
Table 6. NAK Character Setting Examples
1 Desired Character/Value NAK $ @ >
2 Hex equivalent 0x15 0x24 0x40 0x3E
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT NAK CHARACTER SETTING
5 Scan Two Characters From Appendix D, Keypad ‘1’ and ‘5’ ‘2’ and ‘4’ ‘4’ and ‘0’ ‘3’ AND ‘E’
6 Scan ENTER/EXIT PROGRAMMING MODE
RS-232 Parameters References

This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout.
To set this value:
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
This completes the procedure. See the table below for examples of how to set this feature.
Table 7. ACK NAK Timeout Value Setting Examples
1 Desired Setting 200ms 1,000ms (1 sec.) 5200ms (5.2 sec.) 15,000ms (15 sec.)
2 Divide by 200 01 05 26 75
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT ACK NAK TIMEOUT VALUE SETTING
5 Scan Two Characters From
Appendix D, Keypad ‘0’ and ‘1’ ‘0’ and ‘5’ ‘2’ and ‘6’ ‘7’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE
References RS-232 Parameters

This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries.
To set this feature:
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
This completes the procedure. See the table below for examples of how to set this feature.
Table 8. ACK NAK Retry Count Setting Examples
1 Desired Setting Disable Retry
Count 3 Retries 54 Retries Unlimited Retries
2 Pad with leading zero(es) 000 003 054 255
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT ACK NAK RETRY COUNT SETTING
5 Scan Three Characters From
Appendix D, Keypad ‘0’, ‘0’ and ‘0’ ‘0’, ‘0’ and ‘3’ ‘0’, ‘5’ and ‘4’ ‘2’, ‘5’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE
RS-232 Parameters References

Specifies the value of the RS-232 host command used to disable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8- bit data is not recognized when the option Data Bits has been set as 7 Data Bits.
To set the value:
This completes the procedure. See the table below for examples of how to set this feature.
Table 9. Disable Character Setting Examples
1 Desired character/value ‘d’ ‘}’ ‘D’ Disable Command
2 Hex equivalent from ASCII Chart 0x64 0x7D 0x44 0xFF
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT DISABLE CHARACTER VALUE SETTING
5 Scan Two Characters From
Appendix D, Keypad ‘6’ and ‘4’ ‘7’ and ‘D’ ‘4’ and ‘4’ ‘F’ AND ‘F’
6 Scan ENTER/EXIT PROGRAMMING MODE
References RS-232 Parameters · Not Used

Specifies the value of the RS-232 host command used to enable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8- bit data is not recognized when the option Data Bits has been set as 7 Data Bits.
To set this feature:
Determine the desired character or value. A setting of 0xFF indicates the Enable Character is not used (not available).
This completes the procedure. See the table below for examples of how to set this feature.
Table 10. Enable Character Setting Examples
1 Desired character/value ‘e’ ‘}’ ‘E’ Enable Command
2 Hex equivalent from ASCII Chart 0x65 0x7D 0x45 0xFF
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT ENABLE CHARACTER VALUE SETTING
5 Scan Two Characters From
Appendix D, Keypad ‘6’ and ‘5’ ‘7’ and ‘D’ ‘4’ and ‘5’ ‘F’ AND ‘F’
6 Scan ENTER/EXIT PROGRAMMING MODE
RS-232 Parameters References · Not Used

Specifies the amount of time the reader looks for keyboard activity before it breaks the keyboard connection in order to transmit data to host. The range is from 0 to 990ms in 10ms increments.
This feature applies ONLY to the Keyboard Wedge interface.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
This completes the procedure to set the Wedge Quiet Interval. See the table below for examples of how to set this feature.
Table 11. Wedge Quiet Interval Setting Examples
1 Desired Setting 10ms 150ms 600ms 850ms
2 Divide by 10 (and pad with
leading zeroes) 01 15 60 85
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT WEDGE QUIET INTERVAL SETTING
5 Scan Two Characters From
Appendix D, Keypad ‘0’ and ‘1’ ‘1’ and ‘5’ ‘6’ and ‘0’ ‘8’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE
References Keyboard Interface

This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay.
This feature applies ONLY to the Keyboard Wedge interface.
To set the delay:
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
This completes the procedure. See the table below for examples of how to set this feature.
Table 12. Intercharacter Delay Setting Examples
1 Desired Setting 50ms 150ms 600ms 850ms
2 Divide by 10 (and pad with leading zeroes to yield two-
05 15 60 85
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT INTERCHARACTER DELAY SETTING
5 Scan Two Characters From
Appendix D, Keypad ‘0’ and ‘5’ ‘1’ and ‘5’ ‘6’ and ‘0’ ‘8’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE
Keyboard Interface References · digits)

Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds.
Follow these instructions to set this feature:
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
This completes the procedure. See the table below for examples of how to set this feature.
Table 13. Wedge Intercode Delay Examples
1 Desired Setting No Delay 5 Seconds 60 Seconds 99 Seconds
2 Pad with leading zero(es) 00 05 60 99
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT INTERCODE DELAY SETTING
5 Scan Two Characters From
Appendix D, Keypad ‘0’ and ‘0’ ‘0’ and ‘5’ ‘6’ and ‘0’ ‘9’ AND ‘9’
6 Scan ENTER/EXIT PROGRAMMING MODE
References Keyboard Interface

When a bar code is scanned, additional information can be sent to the host computer along with the bar code data. This combination of bar code data and supplementary user-defined data is called a “message string.” The Data Editing features can be used to build specific user-defined data into a message string.
There are several types of selectable data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with specific symbologies. The following shows the available elements you can add to a message string:
Figure 3. Breakdown of a Message String
Label ID Transmission:
Enable this option to transmit the Label ID you configure for the scanned
symbology.
OR...
Prefix Suffix AIM ID Label ID Label ID Bar Code Data
AIM ID: This function is used to identify and display the common label identifier for its symbology. When enabled, this ID code will be transmitted before the scanned bar code data.
Additional advanced editing is available. See the Advanced formatting fea- tures in the Datalogic Aladdin configuration software, or contact Technical Support (as described on page 2) for more information.
Please Keep In Mind...
Data Format References

Up to 20 ASCII characters may be added as a prefix (in a position before the bar code data) and/ or as a suffix (in a position following the bar code data) as indicated.
Figure 4. Prefix and Suffix Positions
OR...
Prefix Suffix AIM ID Label ID Label ID Bar Code Data
In this example, we’ll set a prefix for all symbologies.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
References Data Format

This feature enables/disables addition of AIM IDs for all symbology types.
AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data. AIM label identifiers consist of three characters as follows:
Code 39 and Code 32 A DataBar Omnidirectional, DataBar Expanded e
Codabar F Standard 2 of 5 S
Interleaved 2 of 5 I ISBN Xb
Code 93 G Code 11 H
a. UPC-A and UPC-E labels are converted to EAN 13 when adding AIM IDs.
b. ISBN (X with a 0 modifier character)
Figure 5. AIM ID
Prefix Suffix Label ID Label ID Bar Code Data AIM ID
Data Format References · UPC/EAN Ea · Code 128/GS1-128 C

A Label ID is a customizable code of up to three ASCII characters (each can be one of hex 0x01- 0xFF), used to identify a bar code (symbology) type. It can be appended previous to or following the transmitted bar code data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs as a pre-loaded set or individually per symbology (see "Label ID: Set Individually Per Symbology" on page 57). If you wish to program the reader to always include an industry standard label identifier for ALL symbology types, see "Global AIM ID" on page 55.
The following table lists the pre-loaded label ID sets for the USA and Europe.
Table 14. Label ID Pre-loaded Sets
Symbology USA Label ID set EU Label ID set
ABC Codabar S 530000 S 530000
Codablock F l 6C0000 m 6D0000
Code 39 CIP Y 590000 Y 590000
Code 93 & 260000 U 550000
CODE11 CE 434500 b 620000
CODE32 A 410000 X 580000
CODE39 * 2A0000 V 560000
CODE4 4 340000 4 340000
CODE5 j 6A0000 j 6A0000
DATALOGIC 2OF5 s 730000 s 730000
EAN13 P2 F 460000 L 4C0000
EAN13 P5 F 460000 M 4D0000
EAN13 P8 F 460000 # 230000
EAN8 FF 464600 A 410000
EAN8 P2 FF 464600 J 4A0000
EAN8 P5 FF 464600 K 4B0000

Symbology USA Label ID set EU Label ID set
FOLLETT 2OF5 O 4F0000 O 4F0000
GS1 DATABAR EXPANDED RX 525800 t 740000
GS1 DATABAR LIMITED RL 524C00 v 760000
GS1 DATABAR OMNIDIRECTIONAL R4 523400 u 750000
GS1-128 000000 k 6B0000
I2OF5 i 690000 N 4E0000
Industrial 2 of 5 W 570000 W 570000
Interleaved 2 of 5 CIP HR e 650000 e 650000
ISBT128 f 660000 f 660000
ISSN n 6E0000 n 6E0000
S25 s 730000 P 500000
UPCA P2 A 410000 F 460000
UPCA P5 A 410000 G 470000
UPCA P8 A 410000 Q 510000
UPCE E 450000 D 440000
UPCE P2 E 450000 H 480000
UPCE P5 E 450000 I 490000
UPCE P8 E 450000 E 450000
Data Format References

To configure a Label ID individually for a single symbology:
5. Turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID. For example, if you wish to select an equal sign (=) as a Label ID, the chart indicates its associated hex characters as 3D. Turn to Keypad, starting on page 305 and scan the bar codes representing the hex characters deter mined. For the example given, the characters ‘3’ and ‘D’ would be scanned. More exam ples of Label ID settings are provided in Table 15.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
This completes the steps to configure a Label ID for a given symbology.
Figure 6. Label ID Position Options
Prefix Suffix Label ID Label ID Bar Code Data Aim ID
References Data Format

. Label ID Examples
Determine placement of the Label ID characters BEFORE or AFTER with regard to scanned data using "Label ID Control" on page 57
Enable as Prefix Enable as Suffix Enable as Prefix Enable as Suffix
Scan the bar code selecting the symbology type you wish to designate label ID characters for using Label ID Symbology Selection, starting on page 58.
GS1 DataBar Omnidirectional Code 39 Interleaved 2 of
Find hex equivalents from the ASCII table (inside back cover), then scan in these digits/ characters using the bar codes in the section: Keypad, starting on page 305. f you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
44 42 2A 3D 43 33 2B 50 48
data] [bar code data]PH

References Set Global Mid Label ID Character(s)
Specifies a mid-label ID that is added for transmission between the labels of a two label pair. The expected string is a maximum of 20 characters. When combining two label pairs into a single label for transmission to the host, this label ID can be added to the data, following the first label and preceding the second label.
4. Turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID. For example, if you wish to select the char acters ‘M’, ‘I’ and ‘D’ as a Label ID, the chart indicates its associated hex characters as 4D4944. Turn to Keypad, starting on page 305 and scan the bar codes representing the hex characters determined. For the example given, the characters ‘4’, ‘D’, ‘4’, ‘9’, ‘4’ and ‘4’ would be scanned. More examples of Label ID settings are provided in Table 15.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
This completes the steps to configure a Global Mid Label ID for two label pairs.
Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done.
For example, if you have the character conversion configuration item set to the following: 41423132FFFFFFFF
The first pair is 4142 or AB (41 hex is an ASCII capital A, 42 hex is an ASCII capital B) and the second pair is 3132 or 12 (31 hex is an ASCII 1, 32 is an ASCII 2). The other two pairs are FFFF and FFFF.
With the label, AB12BA21, it would look as follows after the character
conversion: BB22BB22.

Set Global Mid Label ID Character(s) References
The A characters were converted to B characters and the 1 characters were converted to 2 characters. Nothing is done with the last two character pairs, since they are all FF.
To set Character Conversion:
If less than the expected string of 16 characters are selected, scan the ENTER/EXIT bar code twice to accept the selections and exit Pro- gramming Mode.

This feature sets the time after the last label segment is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55 seconds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a trigger pull for each label that is read
Follow these instructions to set this feature:
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
This completes the procedure. See the table below for examples of how to set this feature.
Table 16. Timeout Setting Examples
1 Desired Setting 50ms 150ms 1800ms (1.8 sec.) 2550ms (2.55 sec.)
2 Divide by 10 (and pad with leading zeroes) 005 015 180 255
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT LABEL GONE TIMEOUT SETTING
5 Scan Three Characters From Appendix D, Keypad ‘0’, ‘0’ and ‘5’ ‘0’, ‘1’ and ‘5’ ‘1’, ‘8’ and ‘0’ ‘‘2’, ‘5’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE
References Reading Parameters

This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 0.1 to 25.5 seconds in 100ms increments.
Follow these instructions to set this feature:
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
This completes the procedure. See the table below for examples of how to set this feature.
Table 17. Good Read LED Duration Setting Examples
stays on until next trigger pull
200ms 1500ms (1.5 sec.) 2500ms (2.5 sec.)
2 Divide by 100 (and pad with leading zeroes) 000 002 015 025
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT GOOD READ LED DURATION SETTING
5 Scan Three Characters From Appendix D, Keypad ‘0’, ‘0’ and ‘0’ ‘0’, ‘0’ and ‘2’ ‘0’, ‘1’ and ‘5’ ‘0’, ‘2’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE

Selects the scan operating mode for the reader. Selections are:
- Scanning Active Time has elapsed - a label has been read - the trigger is released
This mode is associated with typical handheld reader operation: when the trigger is pulled, scanning starts and the product scans until the trigger is released, or a label is read, or the maximum Scanning Active Time has elapsed.
Trigger Hold Multiple : When the trigger is pulled, scanning starts and the product scans until the trigger is released or Scanning Active Time has elapsed. Reading a label does not disable scanning. Double Read Timeout prevents undesired multiple reads of the same label while in this mode.
Trigger Pulse Multiple: When the trigger is pulled, continuous scanning is activated until Scanning Active Time has elapsed or the trigger has been released and pulled again. Double Read Timeout prevents undesired multiple reads of the same label while in this mode.
Flashing: The reader flashes1 on and off regardless of the trigger status. Flash rate is controlled by Flash On Time and Flash Off Time. When Flash is ON the reader reads continuously. When Flash is OFF scanning is deactivated.
Always On: No trigger pull is required to read a bar code. Scanning is continually on. Double Read Timeout prevents undesired multiple reads of the same label while in this mode.
Stand Mode: No trigger pull is required to read a bar code. Scanning turns on automatically when an item is placed in reader's field of view. While in a stand watch state, the reader illumination LED goes from dim to maximum bright.
1Controlled by Flash On Time.
References Scanning Features

This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments.
Follow these instructions to set this feature:
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
This completes the procedure. See the table below for examples of how to set this feature.
Table 18. Scanning Active Time Setting Examples
1 Desired Setting 1 Second 90 Sec. (1.5 min.) 180 Sec. (3 min.) 255 Seconds (4.25 min.)
2 Pad leading zero(es) 001 090 180 255
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT SCANNING ACTIVE TIME SETTING
5 Scan Three Characters From Appendix D, Keypad ‘0’, ‘0’ and ‘1’ ‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’ ‘2’, ‘5’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE
Scanning Features References

This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments.
Follow these instructions to set this feature.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
This completes the procedure. See the table below for examples of how to set this feature.
Table 19. Flash On Time Setting Examples
1 Desired Setting 500ms 1,000ms (1 sec.) 5200ms (5.2 sec.) 9,900ms (9.9 sec.)
2 Divide by 100 (and pad with leading zeroes to yield two digits)
05 10 52 99
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT FLASH ON TIME SETTING
5 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘5’ ‘1’ and ‘0’ ‘5’ and ‘2’ ‘9’ and ‘9’
6 Scan ENTER/EXIT PROGRAMMING MODE
References Scanning Features

This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments.
Follow these instructions to set this feature.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
This completes the procedure. See the table below for examples of how to set this feature.
Table 20. Flash Off Time Setting Examples
1 Desired Setting 500ms 1,000ms (1 sec.) 5200ms (5.2 sec.) 9,900ms (9.9 sec.)
2 Divide by 100 (and pad with leading zeroes to yield two digits)
05 10 52 99
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT FLASH OFF TIME SETTING
5 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘5’ ‘1’ and ‘0’ ‘5’ and ‘2’ ‘9’ and ‘9’
6 Scan ENTER/EXIT PROGRAMMING MODE
Scanning Features References

Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some bar code labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level.
Length Control allows you to select either variable length decoding or fixed length decoding for the specified symbology.
Variable Length: For variable length decoding, a minimum and maximum length may be set.
Fixed Length: For fixed length decoding, two different lengths may be set.
This feature specifies one of the bar code lengths for a given symbology. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
Reference the Symbologies section to view the selectable range (number of characters) for the symbology being set.
Follow these instructions to set this feature:
References Symbologies

If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
This completes the procedure. See the table below for examples of how to set this feature.
Table 21. Length 1 Setting Examples
1 Desired Setting 01 Character 07 Characters 52 Characters 74 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT LENGTH 1SETTING for the desired symbology
4 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘1’ ‘0’ and ‘7’ ‘5’ and ‘2’ ‘7’ AND ‘4’
5 Scan ENTER/EXIT PROGRAMMING MODE
Symbologies References

This feature specifies one of the bar code lengths for a given symbology. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
Reference the Symbologies section to view the selectable range (number of characters) for the symbology being set. A setting of 00 specifies to ignore this length (only one fixed length).
Follow these instructions to set this feature:
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
This completes the procedure. See the table below for examples of how to set this feature.
Table 22. Length 2 Setting Examples
1 Desired Setting 00 (ignore sec ond length) 07 Characters 52 Characters 74 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT LENGTH 2 SETTING
4 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘0’ ‘0’ and ‘7’ ‘5’ and ‘2’ ‘7’ and ‘4’
5 Scan ENTER/EXIT PROGRAMMING MODE
References Symbologies

Technical Specifications
The table below contains Physical and Performance Characteristics, User Environment and Regulatory information. Table 25 provides Standard Cable Pinouts.
Table 23.
Dimensions Touch 65: 16.0 x 8.4 x 5.8 cm / 6.3 x 3.3 x 2.3 in Touch 90: 17.0 x 10.4 x 6.7 cm / 6.7 x 4.1 x 2.7 in
Black; TD1130 (Pro) available in White ; Other colors and custom logo options are available for minimum quantity purchase.
Operating (Typical): < 100 mA @ 5 VDC Standby/Idle (Typical): 20 mA @ 5 VDC Max 180mA @ 5VDC
Input Voltage 5 VDC +/- 0.5 V
Print Contrast Ratio (Minimum) 25%
Roll (Tilt) Tolerance ± 45° from normal
Pitch Tolerance ± 65°
Skew (Yaw) Tolerance ± 70°
Reading Indicators Beeper (Adjustable Tone); Good Read LED
Resolution (1D Codes, Maximum)
Touch 65 Minimum Resolution = 4 mil (0.102 mm) Touch 90 Min Resolution = 5 mil (0.127 mm)

Typical Depth Of Field Minimum distance determined by symbol length and scan angle.
Printing resolution, contrast, and ambient light dependent.
Touch 65 Touch 90
1D / Linear Codes Autodiscriminates all standard 1D codes including GS1 DataBar™ linear codes.
Stacked Codes GS1 DataBar Expanded Stacked; GS1 DataBar Stacked; GS1 DataBar Stacked Omnidirectional
Humidity 5 - 95%
Drop specifications Withstands repeated drops from 1.5 m / 5.0 ft onto a con- crete surface
Ambient Light immunity 0 - 20,000 lux
Particulate and Water Sealing IP30
ESD Level 16 kV
LED Emission Class (IEC-62471:2006-07) Exempt Risk Group (RG 0)
Electrical Safety IEC 60950-1 , CAN/CSA C22.2 No. 60950-1-07; UL 60950-1
North America (FCC) : Part 15 Class B, Canada ( IC) : ICES- 003 Class B, European Union EMC Directive, Australian (C- tick), Russia (Gost); Korean KCC ; Japan (VCCI)

Figure 24 and Table 25 provide standard pinout information for the reader’s cable.
Figure 24. Standard Cable Pinouts

The signal descriptions in Table 25 apply to the connector on the reader and are for ref- erence only.
Table 25. Standard Cable Pinouts — Reader Side

Standard Cable Pinouts

The reader’s beeper sounds and its LED illuminates to indicate various functions or er- rors on the reader. The tables below list these indications. One exception to the behaviors listed in the tables is that the reader’s functions are programmable, and may or may not be turned on. For example, certain indications such as the power-up beep can be disabled using programming bar code labels.
Table 26. LED and Beeper Indications
LED flashes/blinks on power-up but this may be
Reader beeps four times at highest frequency and volume upon power-up.
Power-up Beep The reader is in the process of pow ering-up.
too rapid to view. With a USB interface, the LED blinks
until enumeration with the
host is completed.
LED behavior for this indica tion is configurable via the feature “Good Read: When to Indicate”
The reader will beep once at cur rent frequency, volume, mono/bi- tonal setting and duration upon a successful label scan.
Good Read Beep A label has been successfully scanned by the reader.
ROM Failure There is an error in the reader's software/programming
Flashes 200mS on /
200mS off Reader sounds one error beep at highest volume for 200 mS.
Indicates that a host connection is not established when the USB interface is enabled.
Reader 'chirps' six times at the highest frequency and current vol ume.
Limited Scanning Label Read
The reader has been disabled by the host.
The LED blinks continuously 100mS on / 900 mS off N/A
Programming Mode - The following indications ONLY occur when the reader is in Programming Mode.
Label Program- ming Mode Entry
A valid programming label has been scanned. LED blinks continuously Reader sounds four low frequency
beeps.
Label Program- ming Mode Rejec- tion of Label
A label has been rejected. N/A Reader sounds three times at low- est frequency & current volume.
In cases where multiple labels must be scanned to program one feature, this indication acknowl- edges each portion as it is success- fully scanned.
Label Program- ming Mode Accep- tance of Partial Label
Reader sounds one short beep at
highest frequency & current vol-
ume.
Technical Specifications · Reader Disabled

Programming Mode - The following indications ONLY occur when the reader is in Programming Mode.
Label Program- ming Mode Accep- tance of Programming
Configuration option(s) have been successfully programmed via labels and the reader has exited Programming Mode.
Reader sounds one high frequency beep and 4 low frequency beeps followed by reset beeps.
Label Program- ming Mode Can- cel Item Entry
Cancel label has been scanned. N/A Reader sounds two times at low frequency and current volume.
Upon startup, if the reader sounds a long tone, this means the reader has not passed its automatic Selftest and has entered FRU (Field Replaceable Unit) isolation mode. If the reader is reset, the sequence will be repeated. The following table describes the LED flashes/beep codes associated with an error found.
LED FLASHES/
ERROR CORRECTIVE ACTION
BEEPS
Contact Helpdesk for assistance 2 Interface PCB

Technical Specifications

Standard Defaults
The most common configuration settings are listed in the “Default” column of Table 27. The settings in this table are as applied to a standard RS-232 interface. See Table 1 for a listing of default exceptions to this list as applied to other interface types. Page references are also provided for feature descriptions and programming bar codes for each parameter. A column has also been provided for recording of your preferred default settings for these same configurable features.
Table 27. Standard Defaults
Parameter Default Your Setting Page Number
Host Commands — Obey/Ignore Obey 21
USB Suspend Mode Disable 22
Baud Rate 9600 19
Data Bits 8 Data Bits 21
Stop Bits 1 Stop Bit 21
Handshaking Control Disable 23
Intercharacter Delay No Delay 25
Beep On ASCII BEL Disable 26
Beep On Not on File Enable 26
ACK Character ‘ACK’ 28
NAK Character ‘NAK’ 28
ACK NAK Timeout Value 600 ms 29
ACK NAK Retry Count 3 Retries 30
ACK NAK Error Handling Ignore Errors
Indicate Transmission Failure Enable 32
Parity None 22 · Detected 31

Parameter Default Your Setting Page Number
Disable Character ‘D’ 32
Enable Character ‘E’ 33
Country Mode U.S. Keyboard 35
Caps Lock State Caps Lock OFF 38
Keyboard Numeric Keypad Standard Keys 39
Keyboard Send Control Characters Disable 40
Wedge Quiet Interval 100ms 41
Intercharacter Delay No Delay 42
Intercode Delay 100 ms 43
USB Keyboard Speed 1 ms 44
USB-OEM Device Usage Handheld Scanner 48
USB-OEM Interface Options Ignore 48
Wand Signal Speed 660ms 49
Quiet Zones & Spaces Low, Bars
Wand Idle State High 50
Transmit Noise Disable 51
Label Symbology Conversion No conversion 52
Global AIM ID Disable 55
GS1-128 AIM ID Enable 55
Label ID Control Disable 57
Set Global Mid Label ID Character(s) No Characters 64

Parameter Default Your Setting Page Number
Case Conversion Disable 65
Character Conversion No Char Conversion 66
Double Read Timeout 0.6 Second 68
Label Gone Timeout 160 ms 70
Power Save Mode Enabled 71
Sleep Mode Timeout Disabled 72
Power On Alert 4 Beeps 73
Good Read Beep Type Mono 75
Good Read Beep Frequency Medium 75
Good Read Beep Length 80 ms 77
Illumination Control Illumination Off
Good Read Beep Volume High 76
Good Read LED Duration LED on until next trigger pull 79
Scan Mode Trigger Single 80
Stand Mode Triggered Timeout 0.5 Seconds 81
Scanning Active Time 5 Seconds 83
Stand Mode Flash Disable 83
Flash On Time 1 Second 84
Flash Off Time 600 ms 84
Stand Mode Sensitivity Medium 85
Coupon Control Enable only UPC/
UPC-A
UPC-A Enable/Disable Enable 89
during beep 78

Parameter Default Your Setting Page Number
UPC-A Check Character Transmission Enable 89
Expand UPC-A to EAN-13 Don’t Expand 90
UPC-A Number System Character Trans mission Transmit 90
In-Store Minimum Reads 2 91
UPC-E Enable/Disable Enable 92
UPC-E Check Character Transmission Send 92
Expand UPC-E to EAN-13 Don’t Expand 93
Expand UPC-E to UPC-A Don’t Expand 93
UPC-E Number System Character Trans mission Transmit 94
UPC-E Minimum Read 2 94
EAN 13 Enable/Disable Enable 95
EAN 13 Check Character Transmission Send 95
EAN-13 Flag 1 Character Transmit 96
EAN-13 ISBN Conversion Disable 96
ISSN Enable/Disable Disable 97
EAN 13 Minimum Reads 1 97
EAN 8 Enable/Disable Enable 98
EAN 8 Check Character Transmission Send 98
Expand EAN 8 to EAN 13 Disable 99
EAN 8 Both Guards Substitution Disable 99
EAN 8 Guard Insertion Disable 100
EAN 8 Guard Substitution Disable 100
EAN 8 Minimum Segment Length Block 8 101
EAN 8 Minimum Reads 1 103
EAN 8 Stitch Exact Label Halves Disable 104
EAN 8 Stitch Unlike Label Halves Disable 104
Standard Defaults

Parameter Default Your Setting Page Number
EAN Two Label Enable/Disable Disable 105
EAN Two Label Combined Transmission Disable 105
EAN Two Label Minimum Reads 1 Read 106
UPC/EAN Decoding Level 2 107
UPC/EAN Correlation Disable 108
UPC/EAN Price Weight Check Disable 109
UPC-A Minimum Reads 1 Read 110
UPC/EAN Guard Insertion Disable 111
UPC/EAN Stitch Exact Label Halves Disable 111
UPC/EAN Stitch Unlike Label Halves Disable 112
UPC/EAN Minimum Segment Length 5 113
Optional Add-ons Disable P2, P5
Optional Add-On Timer 70 ms 117
P2 Add-Ons Minimum Reads 2 119
P5 Add-Ons Minimum Reads 1 120
GS1-128 Add-Ons Minimum Reads 1 121
GS1 DataBar Omnidirectional Enable/ Disable Disable 122
GS1 DataBar Omnidirectional GS1-128 Emulation Disable 122
GS1 DataBar Omnidirectional Minimum Reads 1 123
GS1 DataBar Expanded Enable/Disable Disable 124
GS1 DataBar Expanded GS1-128 Emula tion Disable 124
GS1 DataBar Expanded Minimum Reads 1 125
and P8 115

Parameter Default Your Setting Page Number
GS1 DataBar Expanded Length Control Variable 126
GS1 DataBar Expanded Set Length 1 1 126
GS1 DataBar Expanded Set Length 2 74 127
GS1 DataBar Limited Enable/Disable Disable 128
GS1 DataBar Limited GS1-128 Emulation Disable 128
GS1 DataBar Limited Minimum Reads 1 129
Code 39 Enable/Disable Enable 130
Code 39 Check Character Calculation Don’t Calculate 131
Code 39 Check Character Transmission Send 132
Code 39 Start/Stop Character Transmis sion Don’t Transmit 132
Code 39 Full ASCII Disable 133
Code 39 Quiet Zones Auto 134
Code 39 Minimum Reads 2 135
Code 39 Decoding Level 3 136
Code 39 Length Control Variable 137
Code 39 Set Length 1 2 138
Code 39 Set Length 2 50 139
Code 39 Interdigit Ratio 4 140
Code 39 Character Correlation Disable 142
Code 39 Stitching Enable 142
Code 32 Enable/Disable Disable 143
Code 32 Check Character Transmission Don’t Send 144
Code 32 Start/Stop Character Transmis sion Don’t Transmit 144
Code 39 CIP Enable/Disable Disable 145
Standard Defaults

Parameter Default Your Setting Page Number
Code 128 Enable/Disable Enable 145
Expand Code 128 to Code 39 Don’t Expand 146
Code 128 Check Character Transmission Don’t Send 146
Code 128 Quiet Zones Auto 148
Code 128 Minimum Reads 1 149
Code 128 Decoding Level 3 150
Code 128 Length Control Variable 151
Code 128 Set Length 1 1 152
Code 128 Set Length 2 80 153
Code 128 Character Correlation Disable 154
Code 128 Stitching Enable 154
GS1-128 Enable Transmit in Code 128
I 2 of 5 Enable/Disable Disable 156
I 2 of 5 Check Character Calculation Disable 157
I 2 of 5 Check Character Transmission Send 158
I 2 of 5 Minimum Reads 2 167
I 2 of 5 Decoding Level 3 160
I 2 of 5 Length Control Variable 161
I 2 of 5 Set Length 1 6 162
I 2 of 5 Set Length 2 50 163
I 2 of 5 Character Correlation Disable 164
I 2 of 5 Stitching Disable 165
Interleaved 2 of 5 CIP HR Enable/Disable Disable 165
Datalogic 2 of 5 Enable/Disable Enable 166
Data Format 155

Parameter Default Your Setting Page Number
Datalogic 2 of 5 Check Character Calcu lation Disable 166
Datalogic 2 of 5 Check Character Trans mission Don’t Send 167
Datalogic 2 of 5 Minimum Reads 2 167
Datalogic 2 of 5 Length Control Variable 168
Datalogic 2 of 5 Set Length 1 12 169
Datalogic 2 of 5 Set Length 2 100 170
Datalogic 2 of 5 Interdigit Ratio 4 171
Datalogic 2 of 5 Character Correlation Disable 173
Datalogic 2 of 5 Stitching Disable 173
Codabar Enable/Disable Disable 174
Codabar Check Character Calculation Don’t Calculate 174
Codabar Check Character Transmission Send 175
Codabar Start/Stop Character Transmis sion Transmit 175
Codabar Start/Stop Character Set abcd/abcd 176
Codabar Start/Stop Character Match Don’t Require Match 177
Codabar Quiet Zones Auto 178
Codabar Minimum Reads 2 179
Codabar Decoding Level 3 180
Codabar Length Control Variable 181
Codabar Set Length 1 3 182
Codabar Set Length 2 50 183
Codabar Interdigit Ratio 4 184
Codabar Character Correlation Disable 186
Codabar Stitching Disable 186
ABC Codabar Enable/Disable Disable 187
ABC Codabar Concatenation Mode Static 187
Standard Defaults

Parameter Default Your Setting Page Number
ABC Codabar Dynamic Concatenation Timeout 200mS 188
ABC Codabar Force Concatenation Disable 188
Code 11 Enable/Disable Disable 189
Code 11 Check Character Calculation Check C and K 190
Code 11 Check Character Transmission Send 190
Code 11 Minimum Reads 2 191
Code 11 Length Control Variable 192
Code 11 Set Length 1 4 192
Code 11 Set Length 2 50 193
Code 11 Interdigit Ratio 4 194
Code 11 Decoding Level 3 196
Code 11 Character Correlation Disable 197
Code 11 Stitching Disable 197
Standard 2 of 5 Enable/Disable Disable 198
Standard 2 of 5 Check Character Calcula tion Disable 198
Standard 2 of 5 Check Character Trans mission Send 199
Standard 2 of 5 Minimum Reads 2 199
Standard 2 of 5 Decoding Level 3 200
Standard 2 of 5 Length Control Variable 200
Standard 2 of 5 Set Length 1 8 201
Standard 2 of 5 Set Length 2 50 202
Standard 2 of 5 Character Correlation Disable 203
Standard 2 of 5 Stitching Disable 203
Industrial 2 of 5 Enable/Disable Disable 204
Industrial 2 of 5 Check Character Calcu lation Disable 204

Parameter Default Your Setting Page Number
Industrial 2 of 5 Check Character Trans mission Enable 205
Industrial 2 of 5 Length Control Variable 205
Industrial 2 of 5 Set Length 1 1 Character 206
Industrial 2 of 5 Set Length 2 50 Characters 207
Industrial 2 of 5 Minimum Reads 1 Read 208
Industrial 2 of 5 Stitching Disable 209
Industrial 2 of 5 Character Correlation Disable 209
IATA Enable/Disable Disable 210
IATA Check Character Transmission Enable 210
ISBT 128 Concatenation Disable 211
ISBT 128 Concatenation Mode Static 211
ISBT 128 Dynamic Concatenation Time out 200ms 212
ISBT 128 Force Concatenation Disable 213
ISBT 128 Advanced Concatenation Options Disable 213
MSI Enable/Disable Disable 214
MSI Check Character Calculation Enable Mod10 214
MSI Check Character Transmission Enable 215
MSI Length Control Variable 215
MSI Set Length 1 1 Character 216
MSI Set Length 2 50 Characters 217
MSI Minimum Reads 4 Reads 218
MSI Decoding Level Level 3 219
Code 93 Enable/Disable Disable 220
Code 93 Check Character Calculation Disable 220
Standard Defaults

Parameter Default Your Setting Page Number
Code 93 Check Character Transmission Enable 221
Code 93 Length Control Variable 221
Code 93 Set Length 1 1 Character 222
Code 93 Set Length 2 50 Characters 223
Code 93 Minimum Reads 1 Read 224
Code 93 Decoding Level Level 3 225
Code 93 Quiet Zones Auto 226
Code 93 Stitching Enable 227
Code 93 Character Correlation Enable 227
Codablock F Enable/Disable Disable 228
Codablock F EAN Enable/Disable Disable 228
Codablock F AIM Check Enable Check C 229
Codablock F Length Control Variable 229
Codablock F Set Length 1 3 Characters 230
Codablock F Set Length 2 100 Characters 231
Code 4 Enable/Disable Disable 232
Code 4 Check Character Transmission Enable 232
Code 4 Hex to Decimal Conversion Enable 233
Code 5 Enable/Disable Disable 233
Code 5 Check Character Transmission Enable 234
Code 5 Hex to Decimal Conversion Enable 234
CODE 4 AND CODE 5 COMMON CONFIGURATION ITEMS
Code 4 and 5 Decoding Level 3 235
Code 4 and Code 5 Minimum Reads 1 236
Follett 2 of 5 Enable/Disable Disable 237

Parameter Default Your Setting Page Number
BC412 Enable/Disable Disable 237
BC412 Check Character Calculation Don’t Calculate 238
BC412 Minimum Reads 2 Reads 238
BC412 Decoding Level 3 239
BC412 Length Control Variable Length 240
BC412 Set Length 1 1 Character 240
BC412 Set Length 2 50 Characters 241
Plessey Enable/Disable Disable 242
Enable Plessey std.
Plessey Check Character Calculation
check char. verification
Plessey Check Character Transmission Enable 244
Plessey Length Control Variable Length 244
Plessey Set Length 1 1 Character 245
Plessey Set Length 2 50 Characters 246
Plessey Minimum Reads 4 247
Plessey Decoding Level 3 248
Plessey Stitching Disable 249
Plessey Character Correlation Disable 249
Table 1. Default Exceptions by Interface Type
Global Suffix No Global Suffix
Double Read Timeout 500 msec
Standard Defaults · Parameter Default Exception · No unique settings

Expand UPC-A to EAN-13 Enable
UPC-E Check Character Transmission Disable
Transmission Label ID Code Prefix
GS1-128 AIM ID Disable
UPCE Label ID Character(s) C
EAN 8 Label ID Character(s) B
EAN 13 Label ID Character(s) A
Code ISBN Label ID Character(s) A
Code 39 Label ID Character(s) M
Interleaved 2of5 Label ID Character(s) I
Code Standard 2/5 Label ID Character(s) H
Codabar Label ID Character(s) N
Code 128 Label ID Character(s) K
GS1-128 Label ID Character(s) P
Datalogic 2 of 5 Label ID Character(s) H
ISBT 128 Label ID Character(s) K
UPCE P2 Label ID Character(s) C
UPCE/P5 Label ID Character(s) C
UPCE/GS1-128 Label ID Character(s) C
EAN8/P2 Label ID Character(s) B
EAN8/P5 Label ID Character(s) B
EAN8/GS1-128 Label ID Character(s) B
EAN13/P2 Label ID Character(s) A
EAN13/P5 Label ID Character(s) A
EAN13/GS1-128 Label ID Character(s) A
GS1 DataBar 14 (Omnidirectional) Label ID Character(s) E
GS1 DataBar Expanded Label ID Character(s) E
GS1 DataBar Limited Label ID Character(s) E
Character Conversion CR to `

Baud Rate 115200 Baud
Transmission Label ID Code Prefix
GS1-128 AIM ID Disable
UPCA Label ID Character(s) C
UPCE Label ID Character(s) D
EAN 8 Label ID Character(s) A
EAN 13 Label ID Character(s) B
Code ISBN Label ID Character(s) @
Code 39 Label ID Character(s) V
Code 32 Label ID Character(s) X
Interleaved 2of5 Label ID Character(s) N
Code Standard 2/5 Label ID Character(s) P
Codabar Label ID Character(s) R
Code 11 Label ID Character(s) b
Code 128 Label ID Character(s) T
GS1-128 Label ID Character(s) k
UPCA/P2 Label ID Character(s) F
UPCA/P5 Label ID Character(s) G
UPCA/GS1-128 Label ID Character(s) Q
UPCE P2 Label ID Character(s) H
UPCE/P5 Label ID Character(s) I
EAN8/P2 Label ID Character(s) J
EAN8/P5 Label ID Character(s) K
EAN8/GS1-128 Label ID Character(s) *
EAN13/P2 Label ID Character(s) L
EAN13/P5 Label ID Character(s) M
EAN13/GS1-128 Label ID Character(s) #
GS1 DataBar 14 (Omnidirectional) Label ID Character(s) u
GS1 DataBar Expanded Label ID Character(s) t
GS1 DataBar Limited Label ID Character(s) v
Standard Defaults · Parameter Default Exception

Sample Bar Codes
The sample bar codes in this appendix are typical representations for their symbology types.
0 12345 67890 5
Code 39
123ABC
Code 128
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4
3 456789 012340

Code 32
Codabar



Sample Bar Codes · 12345678901231

GS1 DataBar variants must be enabled to read the bar codes below (see GS1 DataBar (RSS) on page 303).

10293847560192837465019283746029478450366523 (GS1 DataBar Expanded Stacked)

1234890hjio9900mnb (GS1 DataBar Expanded)
08672345650916 (GS1 DataBar Limited)
55432198673467 (GS1 DataBar Omnidirectional Truncated)
90876523412674 (GS1 DataBar Omnidirectional Stacked)
78123465709811 (GS1 DataBar Omnidirectional Stacked)
GS1 DataBar (RSS)

Sample Bar Codes

Keypad
Use the bar codes in this appendix to enter numbers as you would select digits/characters from a keypad.



Keypad

E
F

Keypad

Scancode Tables
Control character emulation selects from different scancode tables as listed in this appendix. Each of the control character sets below are detailed by interface type in the tables. These apply to Wedge and USB Keyboard platforms.
Control Character 00 — Characters from 00 to 0x1F are sent as control character Ctrl+Keys, special keys are located from 0x80 to 0xA1.
Control Character 01 — Characters from 00 to 0x1F are sent as control character Ctrl+Cap- ital Key, special keys are located from 0x80 to 0xA1.
Control Character 02 — Special keys are located from 00 to 0x1F and characters from 0x80 to 0xFE are intended as an extended ASCII table (Microsoft Windows Codepage 1252 — see page 316).



7x p q r s t u v w x y z { | } ~ Del
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11
x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE xF
2x SP ! " # $ % & ' ( ) * + , - . /
3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
4x @ A B C D E F G H I J K L M N O
5x P Q R S T U V W X Y Z [ \ ] ^ _
6x ` a b c d e f g h i j k l m n o
Ax Cr _ ‘ ƒ „ … † ‡ ˆ ‰ Š ‹ Ś ‹ Œ _
Bx ° ± ² ³ ´ µ ¶ · ¸ ¹ º » ¼ ½ ¾ ¿
Cx À Á Â Ã Ä Å Æ Ç È É Ê Ë Ì Í Î Ï
Dx Ð _ Ò Ó Ô Õ Ö × Ø Ù Ú Û Ü Ý Þ ß
Ex à á â ã ä å æ ç è é ê ë ì í î ï
Fx ð ñ ò ó ô õ ö ÷ ø ù ú û ü ý þ ÿ
Extended characters (sky blue) are sent via dedicated keys (when available in the selected country mode) or by an Alt Mode sequence.
Table 28. Scancode Set When Control Character is 00 or 01
8x _ Sh Sh Ins Ent
9x F12 Home End Pg Up Pg
C(S)+R
STX
DC2
C(S)+Q
C(S)+A
SOH
DC1
C(S)+@
C(S)+P
0x NULL · 1x DLE



7x p q r s t u v w x y z { | } ~ Del
x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE xF
Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10
2x Space ! “ # $ % & ‘ ( ) * + , - . /
3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
4x @ A B C D E F G H I J K L M N O
5x P Q R S T U V W X Y Z [ \ ] ^ _
6x ` a b c d e f g h i j k l m n o
8x _ _ ‘ ƒ „ … † ‡ ˆ ‰ Š ‹ Ś ‹ Œ _
9x _ ‘ ’ “ ” • – — ˜ ™ š › œ _ _ Ÿ
Ax NBSP ¡ ¢ £ ¤ ¥ ¦ § ¨ © ª « ¬ - ® ¯
Bx ° ± ² ³ ´ µ ¶ · ¸ ¹ º » ¼ ½ ¾ ¿
Cx À Á Â Ã Ä Å Æ Ç È É Ê Ë Ì Í Î Ï
Dx Ð _ Ò Ó Ô Õ Ö × Ø Ù Ú Û Ü Ý Þ ß
Ex à á â ã ä å æ ç è é ê ë ì í î ï
Fx ð ñ ò ó ô õ ö ÷ ø ù ú û ü ý þ ÿ
0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S+ Tab Enter
Interface Type PC AT PS/2 or USB-Keyboard — cont.
Table 29. Scancode Set When Control Character is 02
1x Pg


2x A+032 A+033 A+034 A+035 A+036 A+037 A+038 A+039 A+040 A+041 A+042 A+043 A+044 A+045 A+046 A+047
3x A+048 A+049 A+050 A+051 A+052 A+053 A+054 A+055 A+056 A+057 A+058 A+059 A+060 A+061 A+062 A+063
4x A+064 A+065 A+066 A+067 A+068 A+069 A+070 A+071 A+072 A+073 A+074 A+075 A+076 A+077 A+078 A+079
5x A+080 A+081 A+082 A+083 A+084 A+085 A+086 A+087 A+088 A+089 A+090 A+091 A+092 A+093 A+094 A+095
Ax Cr A+0161 A+0162 A+0163 A+0164 A+0165 A+0166 A+0167 A+0168 A+0169 A+0170 A+0171 A+0172 A+0173 A+0174 A+0175
Bx A+0176 A+0177 A+0178 A+0179 A+0180 A+0181 A+0182 A+0183 A+0184 A+0185 A+0186 A+0187 A+0188 A+0189 A+0190 A+0191
Cx A+0192 A+0193 A+0194 A+0195 A+0196 A+0197 A+0198 A+0199 A+0200 A+0201 A+0202 A+0203 A+0204 A+0205 A+0206 A+0207
Dx A+0208 A+0209 A+0210 A+0211 A+0212 A+0213 A+0214 A+0215 A+0216 A+0217 A+0218 A+0219 A+0220 A+0221 A+0222 A+0223
Ex A+0224 A+0225 A+0226 A+0227 A+0228 A+0229 A+0230 A+0231 A+0232 A+0233 A+0234 A+0235 A+0236 A+0237 A+0238 A+0239
Fx A+0240 A+0241 A+0242 A+0243 A+0244 A+0245 A+0246 A+0247 A+0248 A+0249 A+0250 A+0251 A+052 A+0253 A+0254 A+0255
6x A+096 A+097 A+098 A+099 A+100 A+101 A+102 A+103 A+104 A+105 A+106 A+107 A+108 A+109 A+110 A+111
7x A+112 A+113 A+114 A+115 A+116 A+117 A+118 A+119 A+120 A+121 A+122 A+123 A+124 A+125 A+126 A+127
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11
9x F12 Home End Pg Up Pg Dwn Ar Ar Al Al Cl Cl Cr
x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE Xf
1x Alt+016 Alt+017 Alt+018 Alt+019 Alt+020 Alt+021 Alt+022 Alt+023 Alt+024 Alt+025 Alt+026 ESC
0x Alt+000 Alt+001 Alt+002 Alt+003 Alt+004 Alt+005 Alt+006 Alt+007 Alt+008 HT
Table 30. Scancode Set When Control Character is 00 or 01
8x _ Sh Sh? Ins Ent
(keyp)


2x A+032 A+033 A+034 A+035 A+036 A+037 A+038 A+039 A+040 A+041 A+042 A+043 A+044 A+045 A+046 A+047
3x A+048 A+049 A+050 A+051 A+052 A+053 A+054 A+055 A+056 A+057 A+058 A+059 A+060 A+061 A+062 A+063
4x A+064 A+065 A+066 A+067 A+068 A+069 A+070 A+071 A+072 A+073 A+074 A+075 A+076 A+077 A+078 A+079
5x A+080 A+081 A+082 A+083 A+084 A+085 A+086 A+087 A+088 A+089 A+090 A+091 A+092 A+093 A+094 A+095
8x A+0128 A+0129 A+0130 A+0131 A+0132 A+0133 A+0134 A+0135 A+0136 A+0137 A+0138 A+0139 A+0140 A+0141 A+0142 A+0143
9x A+0144 A+0145 A+0146 A+0147 A+0148 A+0149 A+0150 A+0151 A+0152 A+0153 A+0154 A+0155 A+0156 A+0157 A+0158 A+0159
Ax A+0160 A+0161 A+0162 A+0163 A+0164 A+0165 A+0166 A+0167 A+0168 A+0169 A+0170 A+0171 A+0172 A+0173 A+0174 A+0175
Bx A+0176 A+0177 A+0178 A+0179 A+0180 A+0181 A+0182 A+0183 A+0184 A+0185 A+0186 A+0187 A+0188 A+0189 A+0190 A+0191
Cx A+0192 A+0193 A+0194 A+0195 A+0196 A+0197 A+0198 A+0199 A+0200 A+0201 A+0202 A+0203 A+0204 A+0205 A+0206 A+0207
Dx A+0208 A+0209 A+0210 A+0211 A+0212 A+0213 A+0214 A+0215 A+0216 A+0217 A+0218 A+0219 A+0220 A+0221 A+0222 A+0223
Ex A+0224 A+0225 A+0226 A+0227 A+0228 A+0229 A+0230 A+0231 A+0232 A+0233 A+0234 A+0235 A+0236 A+0237 A+0238 A+0239
Fx A+0240 A+0241 A+0242 A+0243 A+0244 A+0245 A+0246 A+0247 A+0248 A+0249 A+0250 A+0251 A+052 A+0253 A+0254 A+0255
6x A+096 A+097 A+098 A+099 A+100 A+101 A+102 A+103 A+104 A+105 A+106 A+107 A+108 A+109 A+110 A+111
7x A+112 A+113 A+114 A+115 A+116 A+117 A+118 A+119 A+120 A+121 A+122 A+123 A+124 A+125 A+126 A+127
x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE xF
Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10
0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S+ Tab Enter
Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode — cont.
Table 31. Scancode Set When Control Character is 02
1x Pg

C(S)+_
7x p q r s t u v w x y z { | } ~ Del
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11
X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF
2x Space ! “ # $ % & ‘ ( ) * + , - . /
3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
4x @ A B C D E F G H I J K L M N O
5x P Q R S T U V W X Y Z [ \ ] ^ _
6x ` a b c d e f g h i j k l m n o
SI
C(S)+N
C(S)+^
9x F12 F13 F14 F15 F16 Cl Cl
RS
CR
GS
C+]
C(S)+L
C(S)+\
FF
FS
C(S)+K
ESC
VT
C(S)+J
C(S)+Z
SUB
LF
C(S)+Y
TAB
EM
HT
C(S)+H
C(S)+X
CAN
BS
Table 32. Scancode Set When Control Character is 00 or 01
C(S)+W
BEL
ETB
C(S)+F
C(S)+V
ACK
SYN
C(S)+E
C(S)+U
ENQ
NAK
C(S)+T
8x Sh Sh Ins Ent
C+D
DC4
C(S)+C
C(S)+S
ETX
DC3
C(S)+B
C(S)+R
STX
DC2
C(S)+Q
C(S)+A
SOH
DC1
Digital Interface
C(S)+@
C(S)+P

7x p q r s t u v w x y z { | } ~ Del
X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF
1x F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10
2x Space ! “ # $ % & ‘ ( ) * + , - . /
3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
4x @ A B C D E F G H I J K L M N O
5x P Q R S T U V W X Y Z [ \ ] ^ _
6x ` a b c d e f g h i j k l m n o
0x Cl Cl BS Tab S+ Tab Enter
Table 33. Scancode Set When Control Character is 02
Digital Interface — cont.
Keypd Enter Ins

C(S)+_
7x p q R s t u v w x y z { | } Del
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11
Dwn Ar Ar Al Al Cl Cl Cr
X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF
2x Space ! “ # $ % & ‘ ( ) * + , - . /
3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
4x @ A B C D E F G H I J K L M N O
5x P Q R S T U V W X Y Z [ \ ] ^ _
6x ‘ a B c d e f g h i j k l m n o
SI
C(S)+N
C(S)+^
SO
RS
CR
GS
C+]
C(S)+L
C(S)+\
FF
FS
C(S)+K
ESC
VT
C(S)+J
C(S)+Z
SUB
LF
C(S)+Y
TAB
EM
HT
C(S)+H
C(S)+X
CAN
BS
Table 34. Scancode Set When Control Character is 00 or 01
C(S)+W
BEL
ETB
C(S)+F
C(S)+V
ACK
SYN
C(S)+E
C(S)+U
ENQ
NAK
C(S)+T
8x Sh? Sh? Ins Ent
9x F12 Home End Pg Up Pg
C+D
DC4
C(S)+C
C(S)+S
ETX
DC3
C(S)+B
C(S)+R
STX
DC2
C(S)+Q
C(S)+A
SOH
DC1
C(S)+@
C(S)+P
IBM XT

Keypd Enter Ins Pg Up
7x p q R s t u v w x y z { | } Del
X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF
Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10
2x Space ! “ # $ % & ‘ ( ) * + , - . /
3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
4x @ A B C D E F G H I J K L M N O
5x P Q R S T U V W X Y Z [ \ ] ^ _
6x ‘ a B c d e f g h i j k l m n o
0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S+ Tab Enter
Table 35. Scancode Set When Control Character is 02
IBM XT — cont.
1x Pg

Windows-1252 is a character encoding of the Latin alphabet, used by default in the legacy com- ponents of Microsoft Windows in English and some other Western languages.

Scancode Tables



ASCII
ASCII
ASCII
Char.
No.
Char.
No.
Char.
No.
Char.
No.
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F
‘ a b c d e
60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F
! “ # $ %
STX ETX EOT ENQ
ACK
BEL
’ ( ) * +
I J K
LF VT FF CR SO
, - . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
N O
n o p q
P Q R S T U V W
t u v w
X Y Z
EM SUB ESC
[ \ ] ^ _
FS GS RS US

Datalogic ADC, Inc. 959 Terry Street Eugene, OR 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140
©2012-13 Datalogic ADC, Inc. 820050614 (Rev C) March 2013
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.