Solis 842

332 pages·10.1 MB·Squeezer·PDF·ENDEFRITNLJA
Solis 842
Table of Contents 404 sections Introduction · About the Touch TD1100 · About this Manual · Overview · … ShowHide
Introductionp.11About the Touch TD1100p.11About this Manualp.11Overviewp.11Conventionsp.12Technical Supportp.12Datalogic Website Supportp.12Reseller Technical Supportp.12Telephone Technical Supportp.13Setupp.15Unpackingp.15Setting Up the Readerp.15Install the Interface Cablep.15Connect Host Interfacep.17Holder/Hands-Free Standp.18Interface Selectionp.19Configuring the Interfacep.19Customizing Configuration Settingsp.22Using the Programming Bar Codesp.22Interface Settingsp.23Configuring Other Featuresp.23Software Version Transmissionp.23Configuration Using Bar Codesp.25Configuration Parametersp.25Host Commands — Obey/Ignorep.27USB Suspend Modep.28RS-232 Only Interfacep.29RS-232 Standard Factory Settingsp.29Baud Ratep.29Data Bitsp.31Stop Bitsp.31Parityp.32Handshaking Controlp.33RS-232/USB-Com Interfacesp.35Standard Factory Settingsp.35Intercharacter Delayp.35Beep On ASCII BELp.36Beep On Not on Filep.36ACK NAK Optionsp.37ACK Characterp.38NAK Characterp.38ACK NAK Timeout Valuep.39ACK NAK Retry Countp.40ACK NAK Error Handlingp.41Indicate Transmission Failurep.42Disable Characterp.42Enable Characterp.43Keyboard Interfacep.45Country Modep.45Caps Lock Statep.48Numlockp.48Keyboard Numeric Keypadp.49Keyboard Send Control Charactersp.50Wedge Quiet Intervalp.51Intercharacter Delayp.52Intercode Delayp.53USB Keyboard Speedp.54USB-OEM Interfacep.57Introductionp.57Standard Factory Settingsp.57USB-OEM Device Usagep.58USB-OEM Interface Optionsp.58Wand Emulation Interfacep.59Wand Signal Speedp.59Wand Polarityp.60Wand Idle Statep.60Transmit Noisep.61Label Symbology Conversionp.62Data Formatp.63Global Prefix/Suffixp.64Global AIM IDp.65GS1-128 AIM IDp.65Label IDp.66Label ID: Pre-loaded Setsp.66Label ID: Set Individually Per Symbologyp.67Label ID Controlp.67Label ID Symbology Selectionp.68Set Global Mid Label ID Character(s)p.74Case Conversionp.75Character Conversionp.76Reading Parametersp.77Double Read Timeoutp.78Label Gone Timeoutp.80Power Save Modep.81Sleep Mode Timeoutp.82LED and Beeper Indicatorsp.83Power On Alertp.83Good Read: When to Indicatep.84Good Read Beep Typep.85Good Read Beep Frequencyp.85Good Read Beep Volumep.86Good Read Beep Lengthp.87Illumination Controlp.88Good Read LED Durationp.89Scanning Featuresp.90Scan Modep.90Stand Mode Triggered Timeoutp.91Scanning Active Timep.93Stand Mode Flashp.93Flash On Timep.94Flash Off Timep.94Stand Mode Sensitivityp.95Symbologiesp.97Introductionp.97Standard Factory Settings for Symbologiesp.97Disable All Symbologiesp.98Coupon Controlp.98UPC-Ap.99UPC-A Enable/Disablep.99UPC-A Check Character Transmissionp.99Expand UPC-A to EAN-13p.100UPC-A Number System Character Transmissionp.100In-Store Minimum Readsp.101UPC-Ep.102UPC-E Enable/Disablep.102UPC-E Check Character Transmissionp.102Expand UPC-E to EAN-13p.103Expand UPC-E to UPC-Ap.103UPC-E Number System Character Transmissionp.104UPC-E Minimum Readp.104EAN 13p.105EAN 13 Enable/Disablep.105EAN 13 Check Character Transmissionp.105EAN-13 Flag 1 Characterp.106EAN-13 ISBN Conversionp.106ISSN Enable/Disablep.107EAN 13 Minimum Readsp.107EAN 8p.108EAN 8 Enable/Disablep.108EAN 8 Check Character Transmissionp.108Expand EAN 8 to EAN 13p.109EAN 8 Both Guards Substitutionp.109EAN 8 Guard Insertionp.110EAN 8 Guard Substitutionp.110EAN 8 Minimum Segment Length Blockp.111EAN 8 Minimum Readsp.113EAN 8 Stitch Exact Label Halvesp.114EAN 8 Stitch Unlike Label Halvesp.114EAN Two Labelp.115EAN Two Label Enable/Disablep.115EAN Two Label Combined Transmissionp.115EAN Two Label Minimum Readsp.116UPC/EAN Global Settingsp.117UPC/EAN Decoding Levelp.117UPC/EAN Correlationp.118UPC/EAN Price Weight Checkp.119UPC-A Minimum Readsp.120UPC/EAN Guard Insertionp.121UPC/EAN Stitch Exact Label Halvesp.121UPC/EAN Stitch Unlike Label Halvesp.122UPC/EAN Minimum Segment Lengthp.123Add-Onsp.125Optional Add-onsp.125Optional Add-On Timerp.127P2 Add-Ons Minimum Readsp.129P5 Add-Ons Minimum Readsp.130GS1-128 Add-Ons Minimum Readsp.131GS1 DataBarTM Omnidirectionalp.132GS1 DataBar Omnidirectional Enable/Disablep.132GS1 DataBar Omnidirectional GS1-128 Emulationp.132GS1 DataBar Omnidirectional Minimum Readsp.133GS1 DataBarTM Expandedp.134GS1 DataBar Expanded Enable/Disablep.134GS1 DataBar Expanded GS1-128 Emulationp.134GS1 DataBar Expanded Minimum Readsp.135GS1 DataBar Expanded Length Controlp.136GS1 DataBar Expanded Set Length 1p.136GS1 DataBar Expanded Set Length 2p.137GS1 DataBarTM Limitedp.138GS1 DataBar Limited Enable/Disablep.138GS1 DataBar Limited GS1-128 Emulationp.138GS1 DataBar Limited Minimum Readsp.139Code 39p.140Code 39 Enable/Disablep.140Code 39 Check Character Calculationp.141Code 39 Check Character Transmissionp.142Code 39 Start/Stop Character Transmissionp.142Code 39 Full ASCIIp.143Code 39 Quiet Zonesp.144Code 39 Minimum Readsp.145Code 39 Decoding Levelp.146Code 39 Length Controlp.147Code 39 Set Length 1p.148Code 39 Set Length 2p.149Code 39 Interdigit Ratiop.150Code 39 Character Correlationp.152Code 39 Stitchingp.152Code 32 (Italian Pharmaceutical)p.153Code 32 Enable/Disablep.153Code 32 Feature Setting Exceptionsp.153Code 32 Check Character Transmissionp.154Code 32 Start/Stop Character Transmissionp.154Code 39 CIP (French Pharmaceutical)p.155Code 39 CIP Enable/Disablep.155Code 128p.155Code 128 Enable/Disablep.155Expand Code 128 to Code 39p.156Code 128 Check Character Transmissionp.156Code 128 Function Character Transmissionp.157Code 128 Sub-Code Change Transmissionp.157Code 128 Quiet Zonesp.158Code 128 Minimum Readsp.159Code 128 Decoding Levelp.160Code 128 Length Controlp.161Code 128 Set Length 1p.162Code 128 Set Length 2p.163Code 128 Character Correlationp.164Code 128 Stitchingp.164GS1-128p.165GS1-128 Enablep.165Interleaved 2 of 5 (I 2 of 5)p.166I 2 of 5 Enable/Disablep.166I 2 of 5 Check Character Calculationp.167I 2 of 5 Check Character Transmissionp.168I 2 of 5 Minimum Readsp.169I 2 of 5 Decoding Levelp.170I 2 of 5 Length Controlp.171I 2 of 5 Set Length 1p.172I 2 of 5 Set Length 2p.173I 2 of 5 Character Correlationp.174I 2 of 5 Zero Patternp.174I 2 of 5 Stitchingp.175Interleaved 2 of 5 CIP HRp.175Interleaved 2 of 5 CIP HR Enable/Disablep.175Datalogic 2 of 5p.176Datalogic 2 of 5 Enable/Disablep.176Datalogic 2 of 5 Check Character Calculationp.176Datalogic 2 of 5 Check Character Transmissionp.177Datalogic 2 of 5 Minimum Readsp.177Datalogic 2 of 5 Decoding Levelp.178Datalogic 2 of 5 Length Controlp.178Datalogic 2 of 5 Set Length 1p.179Datalogic 2 of 5 Set Length 2p.180Datalogic 2 of 5 Interdigit Ratiop.181Datalogic 2 of 5 Character Correlationp.183Datalogic 2 of 5 Stitchingp.183Codabarp.184Codabar Enable/Disablep.184Codabar Check Character Calculationp.184Codabar Check Character Transmissionp.185Codabar Start/Stop Character Transmissionp.185Codabar Start/Stop Character Setp.186Codabar Start/Stop Character Matchp.187Codabar Quiet Zonesp.188Codabar Minimum Readsp.189Codabar Decoding Levelp.190Codabar Length Controlp.191Codabar Set Length 1p.192Codabar Set Length 2p.193Codabar Interdigit Ratiop.194Codabar Character Correlationp.196Codabar Stitchingp.196ABC Codabarp.197ABC Codabar Enable/Disablep.197ABC Codabar Concatenation Modep.197ABC Codabar Dynamic Concatenation Timeoutp.198ABC Codabar Force Concatenationp.198Code 11p.199Code 11 Enable/Disablep.199Code 11 Check Character Calculationp.200Code 11 Check Character Transmissionp.200Code 11 Minimum Readsp.201Code 11 Length Controlp.202Code 11 Set Length 1p.202Code 11 Set Length 2p.203Code 11 Interdigit Ratiop.204Code 11 Decoding Levelp.206Code 11 Character Correlationp.207Code 11 Stitchingp.207Standard 2 of 5p.208Standard 2 of 5 Enable/Disablep.208Standard 2 of 5 Check Character Calculationp.208Standard 2 of 5 Check Character Transmissionp.209Standard 2 of 5 Minimum Readsp.209Standard 2 of 5 Decoding Levelp.210Standard 2 of 5 Length Controlp.210Standard 2 of 5 Set Length 1p.211Standard 2 of 5 Set Length 2p.212Standard 2 of 5 Character Correlationp.213Standard 2 of 5 Stitchingp.213Industrial 2 of 5p.214Industrial 2 of 5 Enable/Disablep.214Industrial 2 of 5 Check Character Calculationp.214Industrial 2 of 5 Check Character Transmissionp.215Industrial 2 of 5 Length Controlp.215Industrial 2 of 5 Set Length 1p.216Industrial 2 of 5 Set Length 2p.217Industrial 2 of 5 Minimum Readsp.218Industrial 2 of 5 Stitchingp.219Industrial 2 of 5 Character Correlationp.219IATAp.220IATA Enable/Disablep.220IATA Check Character Transmissionp.220ISBT 128p.221ISBT 128 Concatenationp.221ISBT 128 Concatenation Modep.221ISBT 128 Dynamic Concatenation Timeoutp.222ISBT 128 Force Concatenationp.223ISBT 128 Advanced Concatenation Optionsp.223MSIp.224MSI Enable/Disablep.224MSI Check Character Calculationp.224MSI Check Character Transmissionp.225MSI Length Controlp.225MSI Set Length 1p.226MSI Set Length 2p.227MSI Minimum Readsp.228MSI Decoding Levelp.229Code 93p.230Code 93 Enable/Disablep.230Code 93 Check Character Calculationp.230Code 93 Check Character Transmissionp.231Code 93 Length Controlp.231Code 93 Set Length 1p.232Code 93 Set Length 2p.233Code 93 Minimum Readsp.234Code 93 Decoding Levelp.235Code 93 Quiet Zonesp.236Code 93 Stitchingp.237Code 93 Character Correlationp.237Codablock Fp.238Codablock F Enable/Disablep.238Codablock F EAN Enable/Disablep.238Codablock F AIM Checkp.239Codablock F Length Controlp.239Codablock F Set Length 1p.240Codablock F Set Length 2p.241Code 4p.242Code 4 Enable/Disablep.242Code 4 Check Character Transmissionp.242Code 4 Hex to Decimal Conversionp.243Code 5p.243Code 5 Enable/Disablep.243Code 5 Check Character Transmissionp.244Code 5 Hex to Decimal Conversionp.244Code 4 and Code 5 Common Configuration Itemsp.245Code 4 and 5 Decoding Levelp.245Code 4 and Code 5 Minimum Readsp.246Follett 2 of 5p.247Follett 2 of 5 Enable/Disablep.247BC412p.247BC412 Enable/Disablep.247BC412 Check Character Calculationp.248BC412 Minimum Readsp.248BC412 Decoding Levelp.249BC412 Length Controlp.250BC412 Set Length 1p.250BC412 Set Length 2p.251Plesseyp.252Plessey Enable/Disablep.252Plessey Check Character Calculationp.253Plessey Check Character Transmissionp.254Plessey Length Controlp.254Plessey Set Length 1p.255Plessey Set Length 2p.256Plessey Minimum Readsp.257Plessey Decoding Levelp.258Plessey Stitchingp.259Plessey Character Correlationp.259Referencesp.261RS-232 Parametersp.262RS-232 Onlyp.262RS-232/USB COM Parametersp.263Keyboard Interfacep.270Wedge Quiet Intervalp.270Intercharacter Delayp.271Intercode Delayp.272Data Formatp.273Data Editingp.273Global Prefix/Suffixp.274Global AIM IDp.275Label IDp.276Set Global Mid Label ID Character(s)p.280Character Conversionp.280Reading Parametersp.282Label Gone Timeoutp.282Good Read LED Durationp.283Scanning Featuresp.284Scan Modep.284Scanning Active Timep.285Flash On Timep.286Flash Off Timep.287Symbologiesp.288Decoding Levelsp.288Set Lengthp.288Technical Specificationsp.291Standard Cable Pinoutsp.293LED and Beeper Indicationsp.294Error Codesp.295Standard Defaultsp.297Default Exceptionsp.308Sample Bar Codesp.3111D Bar Codesp.311GS1 DataBar (RSS)p.313GS1 DataBar-14p.313Keypadp.315Scancode Tablesp.319Control Character Emulationp.319Interface Type PC AT PS/2 or USB-Keyboardp.320Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Modep.322Digital Interfacep.324IBM XTp.326Microsoft Windows Codepage 1252p.328ASCII Chartp.331
Page 1 of the Solis 842 user manual — Touch TD1100 Family General Purpose Corded Handheld
Page 1 · click to enlarge
Page 1
Solis 842 diagram (page 1)
Fig. 1

Touch TD1100 Family General Purpose Corded Handheld

Contact Imager Bar Code Reader

Solis 842 — Touch TD1100 Family General Purpose Corded Handheld diagram (page 1)
Fig. 2 · Touch TD1100 Family General Purpose Corded Handheld
Solis 842 — Touch TD1100 Family General Purpose Corded Handheld diagram (page 1)
Fig. 3 · Touch TD1100 Family General Purpose Corded Handheld
Solis 842 — Touch TD1100 Family General Purpose Corded Handheld diagram (page 1)
Fig. 4 · Touch TD1100 Family General Purpose Corded Handheld
Solis 842 — Touch TD1100 Family General Purpose Corded Handheld diagram (page 1)
Fig. 5 · Touch TD1100 Family General Purpose Corded Handheld
Solis 842 — Touch TD1100 Family General Purpose Corded Handheld diagram (page 1)
Fig. 6 · Touch TD1100 Family General Purpose Corded Handheld
Page 2 of the Solis 842 user manual — Patents
Page 2 · click to enlarge
Page 2

Datalogic ADC, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic ADC, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic ADC”). Owners of Datalogic products are hereby granted a non- exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation. Should future revisions of this manual be published, you can acquire printed versions by con tacting your Datalogic representative. Electronic versions may either be downloadable from the Datalogic website (www.datalogic.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other Datalogic publi cations, please let us know via the "Contact Datalogic" page.

Disclaimer Datalogic has taken reasonable measures to provide information in this manual that is com plete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many coun tries, including the U.S.A. and the E.U. All other brand and product names may be trademarks of their respective owners.

Patents

This product may be covered by one or more of the following patents:

Design Patents: EP2137570. Utility Patents: EP0789315B1; US5481098; US5992740; US6098883; US6454168; US6561427; US7506816.

Additional patents pending.

Page 3 of the Solis 842 user manual — Table of contents
Page 3 · click to enlarge
Page 3

Table of contents

Introductionp.11About the Touch TD1100p.11About this Manualp.11Overviewp.11Conventionsp.12Technical Supportp.12Datalogic Website Supportp.12Reseller Technical Supportp.12Telephone Technical Supportp.13Setupp.15Unpackingp.15Setting Up the Readerp.15Install the Interface Cablep.15Connect Host Interfacep.17Holder/Hands-Free Standp.18Interface Selectionp.19Configuring the Interfacep.19Customizing Configuration Settingsp.22Using the Programming Bar Codesp.22Interface Settingsp.23Configuring Other Featuresp.23Software Version Transmissionp.23Configuration Using Bar Codesp.25Configuration Parametersp.25Host Commands — Obey/Ignorep.27USB Suspend Modep.28RS-232 Only Interfacep.29RS-232 Standard Factory Settingsp.29Baud Ratep.29Data Bitsp.31Stop Bitsp.31Parityp.32Handshaking Controlp.33RS-232/USB-Com Interfacesp.35Standard Factory Settingsp.35Intercharacter Delayp.35Beep On ASCII BELp.36Beep On Not on Filep.36ACK NAK Optionsp.37ACK Characterp.38NAK Characterp.38ACK NAK Timeout Valuep.39ACK NAK Retry Countp.40ACK NAK Error Handlingp.41Indicate Transmission Failurep.42Disable Characterp.42Enable Characterp.43Keyboard Interfacep.45Country Modep.45Caps Lock Statep.48Numlockp.48Keyboard Numeric Keypadp.49Keyboard Send Control Charactersp.50Wedge Quiet Intervalp.51Intercharacter Delayp.52Intercode Delayp.53USB Keyboard Speedp.54USB-OEM Interfacep.57Introductionp.57Standard Factory Settingsp.57USB-OEM Device Usagep.58USB-OEM Interface Optionsp.58Wand Emulation Interfacep.59Wand Signal Speedp.59Wand Polarityp.60Wand Idle Statep.60Transmit Noisep.61Label Symbology Conversionp.62Data Formatp.63Global Prefix/Suffixp.64Global AIM IDp.65GS1-128 AIM IDp.65Label IDp.66Label ID: Pre-loaded Setsp.66Label ID: Set Individually Per Symbologyp.67Label ID Controlp.67Label ID Symbology Selectionp.68Set Global Mid Label ID Character(s)p.74Case Conversionp.75Character Conversionp.76Reading Parametersp.77Double Read Timeoutp.78Label Gone Timeoutp.80Power Save Modep.81Sleep Mode Timeoutp.82LED and Beeper Indicatorsp.83Power On Alertp.83Good Read: When to Indicatep.84Good Read Beep Typep.85Good Read Beep Frequencyp.85Good Read Beep Volumep.86Good Read Beep Lengthp.87Illumination Controlp.88Good Read LED Durationp.89Scanning Featuresp.90Scan Modep.90Stand Mode Triggered Timeoutp.91Scanning Active Timep.93Stand Mode Flashp.93Flash On Timep.94Flash Off Timep.94Stand Mode Sensitivityp.95Symbologiesp.97Introductionp.97Standard Factory Settings for Symbologiesp.97Disable All Symbologiesp.98Coupon Controlp.98UPC-Ap.99UPC-A Enable/Disablep.99UPC-A Check Character Transmissionp.99Expand UPC-A to EAN-13p.100UPC-A Number System Character Transmissionp.100In-Store Minimum Readsp.101UPC-Ep.102UPC-E Enable/Disablep.102UPC-E Check Character Transmissionp.102Expand UPC-E to EAN-13p.103Expand UPC-E to UPC-Ap.103UPC-E Number System Character Transmissionp.104UPC-E Minimum Readp.104EAN 13p.105EAN 13 Enable/Disablep.105EAN 13 Check Character Transmissionp.105EAN-13 Flag 1 Characterp.106EAN-13 ISBN Conversionp.106ISSN Enable/Disablep.107EAN 13 Minimum Readsp.107EAN 8p.108EAN 8 Enable/Disablep.108EAN 8 Check Character Transmissionp.108Expand EAN 8 to EAN 13p.109EAN 8 Both Guards Substitutionp.109EAN 8 Guard Insertionp.110EAN 8 Guard Substitutionp.110EAN 8 Minimum Segment Length Blockp.111EAN 8 Minimum Readsp.113EAN 8 Stitch Exact Label Halvesp.114EAN 8 Stitch Unlike Label Halvesp.114EAN Two Labelp.115EAN Two Label Enable/Disablep.115EAN Two Label Combined Transmissionp.115EAN Two Label Minimum Readsp.116UPC/EAN Global Settingsp.117UPC/EAN Decoding Levelp.117UPC/EAN Correlationp.118UPC/EAN Price Weight Checkp.119UPC-A Minimum Readsp.120UPC/EAN Guard Insertionp.121UPC/EAN Stitch Exact Label Halvesp.121UPC/EAN Stitch Unlike Label Halvesp.122UPC/EAN Minimum Segment Lengthp.123Add-Onsp.125Optional Add-onsp.125Optional Add-On Timerp.127P2 Add-Ons Minimum Readsp.129P5 Add-Ons Minimum Readsp.130GS1-128 Add-Ons Minimum Readsp.131GS1 DataBarTM Omnidirectionalp.132GS1 DataBar Omnidirectional Enable/Disablep.132GS1 DataBar Omnidirectional GS1-128 Emulationp.132GS1 DataBar Omnidirectional Minimum Readsp.133GS1 DataBarTM Expandedp.134GS1 DataBar Expanded Enable/Disablep.134GS1 DataBar Expanded GS1-128 Emulationp.134GS1 DataBar Expanded Minimum Readsp.135GS1 DataBar Expanded Length Controlp.136GS1 DataBar Expanded Set Length 1p.136GS1 DataBar Expanded Set Length 2p.137GS1 DataBarTM Limitedp.138GS1 DataBar Limited Enable/Disablep.138GS1 DataBar Limited GS1-128 Emulationp.138GS1 DataBar Limited Minimum Readsp.139Code 39p.140Code 39 Enable/Disablep.140Code 39 Check Character Calculationp.141Code 39 Check Character Transmissionp.142Code 39 Start/Stop Character Transmissionp.142Code 39 Full ASCIIp.143Code 39 Quiet Zonesp.144Code 39 Minimum Readsp.145Code 39 Decoding Levelp.146Code 39 Length Controlp.147Code 39 Set Length 1p.148Code 39 Set Length 2p.149Code 39 Interdigit Ratiop.150Code 39 Character Correlationp.152Code 39 Stitchingp.152Code 32 (Italian Pharmaceutical)p.153Code 32 Enable/Disablep.153Code 32 Feature Setting Exceptionsp.153Code 32 Check Character Transmissionp.154Code 32 Start/Stop Character Transmissionp.154Code 39 CIP (French Pharmaceutical)p.155Code 39 CIP Enable/Disablep.155Code 128p.155Code 128 Enable/Disablep.155Expand Code 128 to Code 39p.156Code 128 Check Character Transmissionp.156Code 128 Function Character Transmissionp.157Code 128 Sub-Code Change Transmissionp.157Code 128 Quiet Zonesp.158Code 128 Minimum Readsp.159Code 128 Decoding Levelp.160Code 128 Length Controlp.161Code 128 Set Length 1p.162Code 128 Set Length 2p.163Code 128 Character Correlationp.164Code 128 Stitchingp.164GS1-128p.165GS1-128 Enablep.165Interleaved 2 of 5 (I 2 of 5)p.166I 2 of 5 Enable/Disablep.166I 2 of 5 Check Character Calculationp.167I 2 of 5 Check Character Transmissionp.168I 2 of 5 Minimum Readsp.169I 2 of 5 Decoding Levelp.170I 2 of 5 Length Controlp.171I 2 of 5 Set Length 1p.172I 2 of 5 Set Length 2p.173I 2 of 5 Character Correlationp.174I 2 of 5 Zero Patternp.174I 2 of 5 Stitchingp.175Interleaved 2 of 5 CIP HRp.175Interleaved 2 of 5 CIP HR Enable/Disablep.175Datalogic 2 of 5p.176Datalogic 2 of 5 Enable/Disablep.176Datalogic 2 of 5 Check Character Calculationp.176Datalogic 2 of 5 Check Character Transmissionp.177Datalogic 2 of 5 Minimum Readsp.177Datalogic 2 of 5 Decoding Levelp.178Datalogic 2 of 5 Length Controlp.178Datalogic 2 of 5 Set Length 1p.179Datalogic 2 of 5 Set Length 2p.180Datalogic 2 of 5 Interdigit Ratiop.181Datalogic 2 of 5 Character Correlationp.183Datalogic 2 of 5 Stitchingp.183Codabarp.184Codabar Enable/Disablep.184Codabar Check Character Calculationp.184Codabar Check Character Transmissionp.185Codabar Start/Stop Character Transmissionp.185Codabar Start/Stop Character Setp.186Codabar Start/Stop Character Matchp.187Codabar Quiet Zonesp.188Codabar Minimum Readsp.189Codabar Decoding Levelp.190Codabar Length Controlp.191Codabar Set Length 1p.192Codabar Set Length 2p.193Codabar Interdigit Ratiop.194Codabar Character Correlationp.196Codabar Stitchingp.196ABC Codabarp.197ABC Codabar Enable/Disablep.197ABC Codabar Concatenation Modep.197ABC Codabar Dynamic Concatenation Timeoutp.198ABC Codabar Force Concatenationp.198Code 11p.199Code 11 Enable/Disablep.199Code 11 Check Character Calculationp.200Code 11 Check Character Transmissionp.200Code 11 Minimum Readsp.201Code 11 Length Controlp.202Code 11 Set Length 1p.202Code 11 Set Length 2p.203Code 11 Interdigit Ratiop.204Code 11 Decoding Levelp.206Code 11 Character Correlationp.207Code 11 Stitchingp.207Standard 2 of 5p.208Standard 2 of 5 Enable/Disablep.208Standard 2 of 5 Check Character Calculationp.208Standard 2 of 5 Check Character Transmissionp.209Standard 2 of 5 Minimum Readsp.209Standard 2 of 5 Decoding Levelp.210Standard 2 of 5 Length Controlp.210Standard 2 of 5 Set Length 1p.211Standard 2 of 5 Set Length 2p.212Standard 2 of 5 Character Correlationp.213Standard 2 of 5 Stitchingp.213Industrial 2 of 5p.214Industrial 2 of 5 Enable/Disablep.214Industrial 2 of 5 Check Character Calculationp.214Industrial 2 of 5 Check Character Transmissionp.215Industrial 2 of 5 Length Controlp.215Industrial 2 of 5 Set Length 1p.216Industrial 2 of 5 Set Length 2p.217Industrial 2 of 5 Minimum Readsp.218Industrial 2 of 5 Stitchingp.219Industrial 2 of 5 Character Correlationp.219IATAp.220IATA Enable/Disablep.220IATA Check Character Transmissionp.220ISBT 128p.221ISBT 128 Concatenationp.221ISBT 128 Concatenation Modep.221ISBT 128 Dynamic Concatenation Timeoutp.222ISBT 128 Force Concatenationp.223ISBT 128 Advanced Concatenation Optionsp.223MSIp.224MSI Enable/Disablep.224MSI Check Character Calculationp.224MSI Check Character Transmissionp.225MSI Length Controlp.225MSI Set Length 1p.226MSI Set Length 2p.227MSI Minimum Readsp.228MSI Decoding Levelp.229Code 93p.230Code 93 Enable/Disablep.230Code 93 Check Character Calculationp.230Code 93 Check Character Transmissionp.231Code 93 Length Controlp.231Code 93 Set Length 1p.232Code 93 Set Length 2p.233Code 93 Minimum Readsp.234Code 93 Decoding Levelp.235Code 93 Quiet Zonesp.236Code 93 Stitchingp.237Code 93 Character Correlationp.237Codablock Fp.238Codablock F Enable/Disablep.238Codablock F EAN Enable/Disablep.238Codablock F AIM Checkp.239Codablock F Length Controlp.239Codablock F Set Length 1p.240Codablock F Set Length 2p.241Code 4p.242Code 4 Enable/Disablep.242Code 4 Check Character Transmissionp.242Code 4 Hex to Decimal Conversionp.243Code 5p.243Code 5 Enable/Disablep.243Code 5 Check Character Transmissionp.244Code 5 Hex to Decimal Conversionp.244Code 4 and Code 5 Common Configuration Itemsp.245Code 4 and 5 Decoding Levelp.245Code 4 and Code 5 Minimum Readsp.246Follett 2 of 5p.247Follett 2 of 5 Enable/Disablep.247BC412p.247BC412 Enable/Disablep.247BC412 Check Character Calculationp.248BC412 Minimum Readsp.248BC412 Decoding Levelp.249BC412 Length Controlp.250BC412 Set Length 1p.250BC412 Set Length 2p.251Plesseyp.252Plessey Enable/Disablep.252Plessey Check Character Calculationp.253Plessey Check Character Transmissionp.254Plessey Length Controlp.254Plessey Set Length 1p.255Plessey Set Length 2p.256Plessey Minimum Readsp.257Plessey Decoding Levelp.258Plessey Stitchingp.259Plessey Character Correlationp.259Referencesp.261RS-232 Parametersp.262RS-232 Onlyp.262RS-232/USB COM Parametersp.263Keyboard Interfacep.270Wedge Quiet Intervalp.270Intercharacter Delayp.271Intercode Delayp.272Data Formatp.273Data Editingp.273Global Prefix/Suffixp.274Global AIM IDp.275Label IDp.276Set Global Mid Label ID Character(s)p.280Character Conversionp.280Reading Parametersp.282Label Gone Timeoutp.282Good Read LED Durationp.283Scanning Featuresp.284Scan Modep.284Scanning Active Timep.285Flash On Timep.286Flash Off Timep.287Symbologiesp.288Decoding Levelsp.288Set Lengthp.288Technical Specificationsp.291Standard Cable Pinoutsp.293LED and Beeper Indicationsp.294Error Codesp.295Standard Defaultsp.297Default Exceptionsp.308Sample Bar Codesp.3111D Bar Codesp.311GS1 DataBar (RSS)p.313GS1 DataBar-14p.313Keypadp.315Scancode Tablesp.319Control Character Emulationp.319Interface Type PC AT PS/2 or USB-Keyboardp.320Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Modep.322Digital Interfacep.324IBM XTp.326Microsoft Windows Codepage 1252p.328ASCII Chartp.331
Page 4 of the Solis 842 user manual — Table of contents
Page 4 · click to enlarge
Page 4

Table of contents

Introductionp.11About the Touch TD1100p.11About this Manualp.11Overviewp.11Conventionsp.12Technical Supportp.12Datalogic Website Supportp.12Reseller Technical Supportp.12Telephone Technical Supportp.13Setupp.15Unpackingp.15Setting Up the Readerp.15Install the Interface Cablep.15Connect Host Interfacep.17Holder/Hands-Free Standp.18Interface Selectionp.19Configuring the Interfacep.19Customizing Configuration Settingsp.22Using the Programming Bar Codesp.22Interface Settingsp.23Configuring Other Featuresp.23Software Version Transmissionp.23Configuration Using Bar Codesp.25Configuration Parametersp.25Host Commands — Obey/Ignorep.27USB Suspend Modep.28RS-232 Only Interfacep.29RS-232 Standard Factory Settingsp.29Baud Ratep.29Data Bitsp.31Stop Bitsp.31Parityp.32Handshaking Controlp.33RS-232/USB-Com Interfacesp.35Standard Factory Settingsp.35Intercharacter Delayp.35Beep On ASCII BELp.36Beep On Not on Filep.36ACK NAK Optionsp.37ACK Characterp.38NAK Characterp.38ACK NAK Timeout Valuep.39ACK NAK Retry Countp.40ACK NAK Error Handlingp.41Indicate Transmission Failurep.42Disable Characterp.42Enable Characterp.43Keyboard Interfacep.45Country Modep.45Caps Lock Statep.48Numlockp.48Keyboard Numeric Keypadp.49Keyboard Send Control Charactersp.50Wedge Quiet Intervalp.51Intercharacter Delayp.52Intercode Delayp.53USB Keyboard Speedp.54USB-OEM Interfacep.57Introductionp.57Standard Factory Settingsp.57USB-OEM Device Usagep.58USB-OEM Interface Optionsp.58Wand Emulation Interfacep.59Wand Signal Speedp.59Wand Polarityp.60Wand Idle Statep.60Transmit Noisep.61Label Symbology Conversionp.62Data Formatp.63Global Prefix/Suffixp.64Global AIM IDp.65GS1-128 AIM IDp.65Label IDp.66Label ID: Pre-loaded Setsp.66Label ID: Set Individually Per Symbologyp.67Label ID Controlp.67Label ID Symbology Selectionp.68Set Global Mid Label ID Character(s)p.74Case Conversionp.75Character Conversionp.76Reading Parametersp.77Double Read Timeoutp.78Label Gone Timeoutp.80Power Save Modep.81Sleep Mode Timeoutp.82LED and Beeper Indicatorsp.83Power On Alertp.83Good Read: When to Indicatep.84Good Read Beep Typep.85Good Read Beep Frequencyp.85Good Read Beep Volumep.86Good Read Beep Lengthp.87Illumination Controlp.88Good Read LED Durationp.89Scanning Featuresp.90Scan Modep.90Stand Mode Triggered Timeoutp.91Scanning Active Timep.93Stand Mode Flashp.93Flash On Timep.94Flash Off Timep.94Stand Mode Sensitivityp.95Symbologiesp.97Introductionp.97Standard Factory Settings for Symbologiesp.97Disable All Symbologiesp.98Coupon Controlp.98UPC-Ap.99UPC-A Enable/Disablep.99UPC-A Check Character Transmissionp.99Expand UPC-A to EAN-13p.100UPC-A Number System Character Transmissionp.100In-Store Minimum Readsp.101UPC-Ep.102UPC-E Enable/Disablep.102UPC-E Check Character Transmissionp.102Expand UPC-E to EAN-13p.103Expand UPC-E to UPC-Ap.103UPC-E Number System Character Transmissionp.104UPC-E Minimum Readp.104EAN 13p.105EAN 13 Enable/Disablep.105EAN 13 Check Character Transmissionp.105EAN-13 Flag 1 Characterp.106EAN-13 ISBN Conversionp.106ISSN Enable/Disablep.107EAN 13 Minimum Readsp.107EAN 8p.108EAN 8 Enable/Disablep.108EAN 8 Check Character Transmissionp.108Expand EAN 8 to EAN 13p.109EAN 8 Both Guards Substitutionp.109EAN 8 Guard Insertionp.110EAN 8 Guard Substitutionp.110EAN 8 Minimum Segment Length Blockp.111EAN 8 Minimum Readsp.113EAN 8 Stitch Exact Label Halvesp.114EAN 8 Stitch Unlike Label Halvesp.114EAN Two Labelp.115EAN Two Label Enable/Disablep.115EAN Two Label Combined Transmissionp.115EAN Two Label Minimum Readsp.116UPC/EAN Global Settingsp.117UPC/EAN Decoding Levelp.117UPC/EAN Correlationp.118UPC/EAN Price Weight Checkp.119UPC-A Minimum Readsp.120UPC/EAN Guard Insertionp.121UPC/EAN Stitch Exact Label Halvesp.121UPC/EAN Stitch Unlike Label Halvesp.122UPC/EAN Minimum Segment Lengthp.123Add-Onsp.125Optional Add-onsp.125Optional Add-On Timerp.127P2 Add-Ons Minimum Readsp.129P5 Add-Ons Minimum Readsp.130GS1-128 Add-Ons Minimum Readsp.131GS1 DataBarTM Omnidirectionalp.132GS1 DataBar Omnidirectional Enable/Disablep.132GS1 DataBar Omnidirectional GS1-128 Emulationp.132GS1 DataBar Omnidirectional Minimum Readsp.133GS1 DataBarTM Expandedp.134GS1 DataBar Expanded Enable/Disablep.134GS1 DataBar Expanded GS1-128 Emulationp.134GS1 DataBar Expanded Minimum Readsp.135GS1 DataBar Expanded Length Controlp.136GS1 DataBar Expanded Set Length 1p.136GS1 DataBar Expanded Set Length 2p.137GS1 DataBarTM Limitedp.138GS1 DataBar Limited Enable/Disablep.138GS1 DataBar Limited GS1-128 Emulationp.138GS1 DataBar Limited Minimum Readsp.139Code 39p.140Code 39 Enable/Disablep.140Code 39 Check Character Calculationp.141Code 39 Check Character Transmissionp.142Code 39 Start/Stop Character Transmissionp.142Code 39 Full ASCIIp.143Code 39 Quiet Zonesp.144Code 39 Minimum Readsp.145Code 39 Decoding Levelp.146Code 39 Length Controlp.147Code 39 Set Length 1p.148Code 39 Set Length 2p.149Code 39 Interdigit Ratiop.150Code 39 Character Correlationp.152Code 39 Stitchingp.152Code 32 (Italian Pharmaceutical)p.153Code 32 Enable/Disablep.153Code 32 Feature Setting Exceptionsp.153Code 32 Check Character Transmissionp.154Code 32 Start/Stop Character Transmissionp.154Code 39 CIP (French Pharmaceutical)p.155Code 39 CIP Enable/Disablep.155Code 128p.155Code 128 Enable/Disablep.155Expand Code 128 to Code 39p.156Code 128 Check Character Transmissionp.156Code 128 Function Character Transmissionp.157Code 128 Sub-Code Change Transmissionp.157Code 128 Quiet Zonesp.158Code 128 Minimum Readsp.159Code 128 Decoding Levelp.160Code 128 Length Controlp.161Code 128 Set Length 1p.162Code 128 Set Length 2p.163Code 128 Character Correlationp.164Code 128 Stitchingp.164GS1-128p.165GS1-128 Enablep.165Interleaved 2 of 5 (I 2 of 5)p.166I 2 of 5 Enable/Disablep.166I 2 of 5 Check Character Calculationp.167I 2 of 5 Check Character Transmissionp.168I 2 of 5 Minimum Readsp.169I 2 of 5 Decoding Levelp.170I 2 of 5 Length Controlp.171I 2 of 5 Set Length 1p.172I 2 of 5 Set Length 2p.173I 2 of 5 Character Correlationp.174I 2 of 5 Zero Patternp.174I 2 of 5 Stitchingp.175Interleaved 2 of 5 CIP HRp.175Interleaved 2 of 5 CIP HR Enable/Disablep.175Datalogic 2 of 5p.176Datalogic 2 of 5 Enable/Disablep.176Datalogic 2 of 5 Check Character Calculationp.176Datalogic 2 of 5 Check Character Transmissionp.177Datalogic 2 of 5 Minimum Readsp.177Datalogic 2 of 5 Decoding Levelp.178Datalogic 2 of 5 Length Controlp.178Datalogic 2 of 5 Set Length 1p.179Datalogic 2 of 5 Set Length 2p.180Datalogic 2 of 5 Interdigit Ratiop.181Datalogic 2 of 5 Character Correlationp.183Datalogic 2 of 5 Stitchingp.183Codabarp.184Codabar Enable/Disablep.184Codabar Check Character Calculationp.184Codabar Check Character Transmissionp.185Codabar Start/Stop Character Transmissionp.185Codabar Start/Stop Character Setp.186Codabar Start/Stop Character Matchp.187Codabar Quiet Zonesp.188Codabar Minimum Readsp.189Codabar Decoding Levelp.190Codabar Length Controlp.191Codabar Set Length 1p.192Codabar Set Length 2p.193Codabar Interdigit Ratiop.194Codabar Character Correlationp.196Codabar Stitchingp.196ABC Codabarp.197ABC Codabar Enable/Disablep.197ABC Codabar Concatenation Modep.197ABC Codabar Dynamic Concatenation Timeoutp.198ABC Codabar Force Concatenationp.198Code 11p.199Code 11 Enable/Disablep.199Code 11 Check Character Calculationp.200Code 11 Check Character Transmissionp.200Code 11 Minimum Readsp.201Code 11 Length Controlp.202Code 11 Set Length 1p.202Code 11 Set Length 2p.203Code 11 Interdigit Ratiop.204Code 11 Decoding Levelp.206Code 11 Character Correlationp.207Code 11 Stitchingp.207Standard 2 of 5p.208Standard 2 of 5 Enable/Disablep.208Standard 2 of 5 Check Character Calculationp.208Standard 2 of 5 Check Character Transmissionp.209Standard 2 of 5 Minimum Readsp.209Standard 2 of 5 Decoding Levelp.210Standard 2 of 5 Length Controlp.210Standard 2 of 5 Set Length 1p.211Standard 2 of 5 Set Length 2p.212Standard 2 of 5 Character Correlationp.213Standard 2 of 5 Stitchingp.213Industrial 2 of 5p.214Industrial 2 of 5 Enable/Disablep.214Industrial 2 of 5 Check Character Calculationp.214Industrial 2 of 5 Check Character Transmissionp.215Industrial 2 of 5 Length Controlp.215Industrial 2 of 5 Set Length 1p.216Industrial 2 of 5 Set Length 2p.217Industrial 2 of 5 Minimum Readsp.218Industrial 2 of 5 Stitchingp.219Industrial 2 of 5 Character Correlationp.219IATAp.220IATA Enable/Disablep.220IATA Check Character Transmissionp.220ISBT 128p.221ISBT 128 Concatenationp.221ISBT 128 Concatenation Modep.221ISBT 128 Dynamic Concatenation Timeoutp.222ISBT 128 Force Concatenationp.223ISBT 128 Advanced Concatenation Optionsp.223MSIp.224MSI Enable/Disablep.224MSI Check Character Calculationp.224MSI Check Character Transmissionp.225MSI Length Controlp.225MSI Set Length 1p.226MSI Set Length 2p.227MSI Minimum Readsp.228MSI Decoding Levelp.229Code 93p.230Code 93 Enable/Disablep.230Code 93 Check Character Calculationp.230Code 93 Check Character Transmissionp.231Code 93 Length Controlp.231Code 93 Set Length 1p.232Code 93 Set Length 2p.233Code 93 Minimum Readsp.234Code 93 Decoding Levelp.235Code 93 Quiet Zonesp.236Code 93 Stitchingp.237Code 93 Character Correlationp.237Codablock Fp.238Codablock F Enable/Disablep.238Codablock F EAN Enable/Disablep.238Codablock F AIM Checkp.239Codablock F Length Controlp.239Codablock F Set Length 1p.240Codablock F Set Length 2p.241Code 4p.242Code 4 Enable/Disablep.242Code 4 Check Character Transmissionp.242Code 4 Hex to Decimal Conversionp.243Code 5p.243Code 5 Enable/Disablep.243Code 5 Check Character Transmissionp.244Code 5 Hex to Decimal Conversionp.244Code 4 and Code 5 Common Configuration Itemsp.245Code 4 and 5 Decoding Levelp.245Code 4 and Code 5 Minimum Readsp.246Follett 2 of 5p.247Follett 2 of 5 Enable/Disablep.247BC412p.247BC412 Enable/Disablep.247BC412 Check Character Calculationp.248BC412 Minimum Readsp.248BC412 Decoding Levelp.249BC412 Length Controlp.250BC412 Set Length 1p.250BC412 Set Length 2p.251Plesseyp.252Plessey Enable/Disablep.252Plessey Check Character Calculationp.253Plessey Check Character Transmissionp.254Plessey Length Controlp.254Plessey Set Length 1p.255Plessey Set Length 2p.256Plessey Minimum Readsp.257Plessey Decoding Levelp.258Plessey Stitchingp.259Plessey Character Correlationp.259Referencesp.261RS-232 Parametersp.262RS-232 Onlyp.262RS-232/USB COM Parametersp.263Keyboard Interfacep.270Wedge Quiet Intervalp.270Intercharacter Delayp.271Intercode Delayp.272Data Formatp.273Data Editingp.273Global Prefix/Suffixp.274Global AIM IDp.275Label IDp.276Set Global Mid Label ID Character(s)p.280Character Conversionp.280Reading Parametersp.282Label Gone Timeoutp.282Good Read LED Durationp.283Scanning Featuresp.284Scan Modep.284Scanning Active Timep.285Flash On Timep.286Flash Off Timep.287Symbologiesp.288Decoding Levelsp.288Set Lengthp.288Technical Specificationsp.291Standard Cable Pinoutsp.293LED and Beeper Indicationsp.294Error Codesp.295Standard Defaultsp.297Default Exceptionsp.308Sample Bar Codesp.3111D Bar Codesp.311GS1 DataBar (RSS)p.313GS1 DataBar-14p.313Keypadp.315Scancode Tablesp.319Control Character Emulationp.319Interface Type PC AT PS/2 or USB-Keyboardp.320Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Modep.322Digital Interfacep.324IBM XTp.326Microsoft Windows Codepage 1252p.328ASCII Chartp.331
Page 5 of the Solis 842 user manual — Table of contents
Page 5 · click to enlarge
Page 5

Table of contents

Introductionp.11About the Touch TD1100p.11About this Manualp.11Overviewp.11Conventionsp.12Technical Supportp.12Datalogic Website Supportp.12Reseller Technical Supportp.12Telephone Technical Supportp.13Setupp.15Unpackingp.15Setting Up the Readerp.15Install the Interface Cablep.15Connect Host Interfacep.17Holder/Hands-Free Standp.18Interface Selectionp.19Configuring the Interfacep.19Customizing Configuration Settingsp.22Using the Programming Bar Codesp.22Interface Settingsp.23Configuring Other Featuresp.23Software Version Transmissionp.23Configuration Using Bar Codesp.25Configuration Parametersp.25Host Commands — Obey/Ignorep.27USB Suspend Modep.28RS-232 Only Interfacep.29RS-232 Standard Factory Settingsp.29Baud Ratep.29Data Bitsp.31Stop Bitsp.31Parityp.32Handshaking Controlp.33RS-232/USB-Com Interfacesp.35Standard Factory Settingsp.35Intercharacter Delayp.35Beep On ASCII BELp.36Beep On Not on Filep.36ACK NAK Optionsp.37ACK Characterp.38NAK Characterp.38ACK NAK Timeout Valuep.39ACK NAK Retry Countp.40ACK NAK Error Handlingp.41Indicate Transmission Failurep.42Disable Characterp.42Enable Characterp.43Keyboard Interfacep.45Country Modep.45Caps Lock Statep.48Numlockp.48Keyboard Numeric Keypadp.49Keyboard Send Control Charactersp.50Wedge Quiet Intervalp.51Intercharacter Delayp.52Intercode Delayp.53USB Keyboard Speedp.54USB-OEM Interfacep.57Introductionp.57Standard Factory Settingsp.57USB-OEM Device Usagep.58USB-OEM Interface Optionsp.58Wand Emulation Interfacep.59Wand Signal Speedp.59Wand Polarityp.60Wand Idle Statep.60Transmit Noisep.61Label Symbology Conversionp.62Data Formatp.63Global Prefix/Suffixp.64Global AIM IDp.65GS1-128 AIM IDp.65Label IDp.66Label ID: Pre-loaded Setsp.66Label ID: Set Individually Per Symbologyp.67Label ID Controlp.67Label ID Symbology Selectionp.68Set Global Mid Label ID Character(s)p.74Case Conversionp.75Character Conversionp.76Reading Parametersp.77Double Read Timeoutp.78Label Gone Timeoutp.80Power Save Modep.81Sleep Mode Timeoutp.82LED and Beeper Indicatorsp.83Power On Alertp.83Good Read: When to Indicatep.84Good Read Beep Typep.85Good Read Beep Frequencyp.85Good Read Beep Volumep.86Good Read Beep Lengthp.87Illumination Controlp.88Good Read LED Durationp.89Scanning Featuresp.90Scan Modep.90Stand Mode Triggered Timeoutp.91Scanning Active Timep.93Stand Mode Flashp.93Flash On Timep.94Flash Off Timep.94Stand Mode Sensitivityp.95Symbologiesp.97Introductionp.97Standard Factory Settings for Symbologiesp.97Disable All Symbologiesp.98Coupon Controlp.98UPC-Ap.99UPC-A Enable/Disablep.99UPC-A Check Character Transmissionp.99Expand UPC-A to EAN-13p.100UPC-A Number System Character Transmissionp.100In-Store Minimum Readsp.101UPC-Ep.102UPC-E Enable/Disablep.102UPC-E Check Character Transmissionp.102Expand UPC-E to EAN-13p.103Expand UPC-E to UPC-Ap.103UPC-E Number System Character Transmissionp.104UPC-E Minimum Readp.104EAN 13p.105EAN 13 Enable/Disablep.105EAN 13 Check Character Transmissionp.105EAN-13 Flag 1 Characterp.106EAN-13 ISBN Conversionp.106ISSN Enable/Disablep.107EAN 13 Minimum Readsp.107EAN 8p.108EAN 8 Enable/Disablep.108EAN 8 Check Character Transmissionp.108Expand EAN 8 to EAN 13p.109EAN 8 Both Guards Substitutionp.109EAN 8 Guard Insertionp.110EAN 8 Guard Substitutionp.110EAN 8 Minimum Segment Length Blockp.111EAN 8 Minimum Readsp.113EAN 8 Stitch Exact Label Halvesp.114EAN 8 Stitch Unlike Label Halvesp.114EAN Two Labelp.115EAN Two Label Enable/Disablep.115EAN Two Label Combined Transmissionp.115EAN Two Label Minimum Readsp.116UPC/EAN Global Settingsp.117UPC/EAN Decoding Levelp.117UPC/EAN Correlationp.118UPC/EAN Price Weight Checkp.119UPC-A Minimum Readsp.120UPC/EAN Guard Insertionp.121UPC/EAN Stitch Exact Label Halvesp.121UPC/EAN Stitch Unlike Label Halvesp.122UPC/EAN Minimum Segment Lengthp.123Add-Onsp.125Optional Add-onsp.125Optional Add-On Timerp.127P2 Add-Ons Minimum Readsp.129P5 Add-Ons Minimum Readsp.130GS1-128 Add-Ons Minimum Readsp.131GS1 DataBarTM Omnidirectionalp.132GS1 DataBar Omnidirectional Enable/Disablep.132GS1 DataBar Omnidirectional GS1-128 Emulationp.132GS1 DataBar Omnidirectional Minimum Readsp.133GS1 DataBarTM Expandedp.134GS1 DataBar Expanded Enable/Disablep.134GS1 DataBar Expanded GS1-128 Emulationp.134GS1 DataBar Expanded Minimum Readsp.135GS1 DataBar Expanded Length Controlp.136GS1 DataBar Expanded Set Length 1p.136GS1 DataBar Expanded Set Length 2p.137GS1 DataBarTM Limitedp.138GS1 DataBar Limited Enable/Disablep.138GS1 DataBar Limited GS1-128 Emulationp.138GS1 DataBar Limited Minimum Readsp.139Code 39p.140Code 39 Enable/Disablep.140Code 39 Check Character Calculationp.141Code 39 Check Character Transmissionp.142Code 39 Start/Stop Character Transmissionp.142Code 39 Full ASCIIp.143Code 39 Quiet Zonesp.144Code 39 Minimum Readsp.145Code 39 Decoding Levelp.146Code 39 Length Controlp.147Code 39 Set Length 1p.148Code 39 Set Length 2p.149Code 39 Interdigit Ratiop.150Code 39 Character Correlationp.152Code 39 Stitchingp.152Code 32 (Italian Pharmaceutical)p.153Code 32 Enable/Disablep.153Code 32 Feature Setting Exceptionsp.153Code 32 Check Character Transmissionp.154Code 32 Start/Stop Character Transmissionp.154Code 39 CIP (French Pharmaceutical)p.155Code 39 CIP Enable/Disablep.155Code 128p.155Code 128 Enable/Disablep.155Expand Code 128 to Code 39p.156Code 128 Check Character Transmissionp.156Code 128 Function Character Transmissionp.157Code 128 Sub-Code Change Transmissionp.157Code 128 Quiet Zonesp.158Code 128 Minimum Readsp.159Code 128 Decoding Levelp.160Code 128 Length Controlp.161Code 128 Set Length 1p.162Code 128 Set Length 2p.163Code 128 Character Correlationp.164Code 128 Stitchingp.164GS1-128p.165GS1-128 Enablep.165Interleaved 2 of 5 (I 2 of 5)p.166I 2 of 5 Enable/Disablep.166I 2 of 5 Check Character Calculationp.167I 2 of 5 Check Character Transmissionp.168I 2 of 5 Minimum Readsp.169I 2 of 5 Decoding Levelp.170I 2 of 5 Length Controlp.171I 2 of 5 Set Length 1p.172I 2 of 5 Set Length 2p.173I 2 of 5 Character Correlationp.174I 2 of 5 Zero Patternp.174I 2 of 5 Stitchingp.175Interleaved 2 of 5 CIP HRp.175Interleaved 2 of 5 CIP HR Enable/Disablep.175Datalogic 2 of 5p.176Datalogic 2 of 5 Enable/Disablep.176Datalogic 2 of 5 Check Character Calculationp.176Datalogic 2 of 5 Check Character Transmissionp.177Datalogic 2 of 5 Minimum Readsp.177Datalogic 2 of 5 Decoding Levelp.178Datalogic 2 of 5 Length Controlp.178Datalogic 2 of 5 Set Length 1p.179Datalogic 2 of 5 Set Length 2p.180Datalogic 2 of 5 Interdigit Ratiop.181Datalogic 2 of 5 Character Correlationp.183Datalogic 2 of 5 Stitchingp.183Codabarp.184Codabar Enable/Disablep.184Codabar Check Character Calculationp.184Codabar Check Character Transmissionp.185Codabar Start/Stop Character Transmissionp.185Codabar Start/Stop Character Setp.186Codabar Start/Stop Character Matchp.187Codabar Quiet Zonesp.188Codabar Minimum Readsp.189Codabar Decoding Levelp.190Codabar Length Controlp.191Codabar Set Length 1p.192Codabar Set Length 2p.193Codabar Interdigit Ratiop.194Codabar Character Correlationp.196Codabar Stitchingp.196ABC Codabarp.197ABC Codabar Enable/Disablep.197ABC Codabar Concatenation Modep.197ABC Codabar Dynamic Concatenation Timeoutp.198ABC Codabar Force Concatenationp.198Code 11p.199Code 11 Enable/Disablep.199Code 11 Check Character Calculationp.200Code 11 Check Character Transmissionp.200Code 11 Minimum Readsp.201Code 11 Length Controlp.202Code 11 Set Length 1p.202Code 11 Set Length 2p.203Code 11 Interdigit Ratiop.204Code 11 Decoding Levelp.206Code 11 Character Correlationp.207Code 11 Stitchingp.207Standard 2 of 5p.208Standard 2 of 5 Enable/Disablep.208Standard 2 of 5 Check Character Calculationp.208Standard 2 of 5 Check Character Transmissionp.209Standard 2 of 5 Minimum Readsp.209Standard 2 of 5 Decoding Levelp.210Standard 2 of 5 Length Controlp.210Standard 2 of 5 Set Length 1p.211Standard 2 of 5 Set Length 2p.212Standard 2 of 5 Character Correlationp.213Standard 2 of 5 Stitchingp.213Industrial 2 of 5p.214Industrial 2 of 5 Enable/Disablep.214Industrial 2 of 5 Check Character Calculationp.214Industrial 2 of 5 Check Character Transmissionp.215Industrial 2 of 5 Length Controlp.215Industrial 2 of 5 Set Length 1p.216Industrial 2 of 5 Set Length 2p.217Industrial 2 of 5 Minimum Readsp.218Industrial 2 of 5 Stitchingp.219Industrial 2 of 5 Character Correlationp.219IATAp.220IATA Enable/Disablep.220IATA Check Character Transmissionp.220ISBT 128p.221ISBT 128 Concatenationp.221ISBT 128 Concatenation Modep.221ISBT 128 Dynamic Concatenation Timeoutp.222ISBT 128 Force Concatenationp.223ISBT 128 Advanced Concatenation Optionsp.223MSIp.224MSI Enable/Disablep.224MSI Check Character Calculationp.224MSI Check Character Transmissionp.225MSI Length Controlp.225MSI Set Length 1p.226MSI Set Length 2p.227MSI Minimum Readsp.228MSI Decoding Levelp.229Code 93p.230Code 93 Enable/Disablep.230Code 93 Check Character Calculationp.230Code 93 Check Character Transmissionp.231Code 93 Length Controlp.231Code 93 Set Length 1p.232Code 93 Set Length 2p.233Code 93 Minimum Readsp.234Code 93 Decoding Levelp.235Code 93 Quiet Zonesp.236Code 93 Stitchingp.237Code 93 Character Correlationp.237Codablock Fp.238Codablock F Enable/Disablep.238Codablock F EAN Enable/Disablep.238Codablock F AIM Checkp.239Codablock F Length Controlp.239Codablock F Set Length 1p.240Codablock F Set Length 2p.241Code 4p.242Code 4 Enable/Disablep.242Code 4 Check Character Transmissionp.242Code 4 Hex to Decimal Conversionp.243Code 5p.243Code 5 Enable/Disablep.243Code 5 Check Character Transmissionp.244Code 5 Hex to Decimal Conversionp.244Code 4 and Code 5 Common Configuration Itemsp.245Code 4 and 5 Decoding Levelp.245Code 4 and Code 5 Minimum Readsp.246Follett 2 of 5p.247Follett 2 of 5 Enable/Disablep.247BC412p.247BC412 Enable/Disablep.247BC412 Check Character Calculationp.248BC412 Minimum Readsp.248BC412 Decoding Levelp.249BC412 Length Controlp.250BC412 Set Length 1p.250BC412 Set Length 2p.251Plesseyp.252Plessey Enable/Disablep.252Plessey Check Character Calculationp.253Plessey Check Character Transmissionp.254Plessey Length Controlp.254Plessey Set Length 1p.255Plessey Set Length 2p.256Plessey Minimum Readsp.257Plessey Decoding Levelp.258Plessey Stitchingp.259Plessey Character Correlationp.259Referencesp.261RS-232 Parametersp.262RS-232 Onlyp.262RS-232/USB COM Parametersp.263Keyboard Interfacep.270Wedge Quiet Intervalp.270Intercharacter Delayp.271Intercode Delayp.272Data Formatp.273Data Editingp.273Global Prefix/Suffixp.274Global AIM IDp.275Label IDp.276Set Global Mid Label ID Character(s)p.280Character Conversionp.280Reading Parametersp.282Label Gone Timeoutp.282Good Read LED Durationp.283Scanning Featuresp.284Scan Modep.284Scanning Active Timep.285Flash On Timep.286Flash Off Timep.287Symbologiesp.288Decoding Levelsp.288Set Lengthp.288Technical Specificationsp.291Standard Cable Pinoutsp.293LED and Beeper Indicationsp.294Error Codesp.295Standard Defaultsp.297Default Exceptionsp.308Sample Bar Codesp.3111D Bar Codesp.311GS1 DataBar (RSS)p.313GS1 DataBar-14p.313Keypadp.315Scancode Tablesp.319Control Character Emulationp.319Interface Type PC AT PS/2 or USB-Keyboardp.320Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Modep.322Digital Interfacep.324IBM XTp.326Microsoft Windows Codepage 1252p.328ASCII Chartp.331
Page 6 of the Solis 842 user manual — Table of contents
Page 6 · click to enlarge
Page 6

Table of contents

Introductionp.11About the Touch TD1100p.11About this Manualp.11Overviewp.11Conventionsp.12Technical Supportp.12Datalogic Website Supportp.12Reseller Technical Supportp.12Telephone Technical Supportp.13Setupp.15Unpackingp.15Setting Up the Readerp.15Install the Interface Cablep.15Connect Host Interfacep.17Holder/Hands-Free Standp.18Interface Selectionp.19Configuring the Interfacep.19Customizing Configuration Settingsp.22Using the Programming Bar Codesp.22Interface Settingsp.23Configuring Other Featuresp.23Software Version Transmissionp.23Configuration Using Bar Codesp.25Configuration Parametersp.25Host Commands — Obey/Ignorep.27USB Suspend Modep.28RS-232 Only Interfacep.29RS-232 Standard Factory Settingsp.29Baud Ratep.29Data Bitsp.31Stop Bitsp.31Parityp.32Handshaking Controlp.33RS-232/USB-Com Interfacesp.35Standard Factory Settingsp.35Intercharacter Delayp.35Beep On ASCII BELp.36Beep On Not on Filep.36ACK NAK Optionsp.37ACK Characterp.38NAK Characterp.38ACK NAK Timeout Valuep.39ACK NAK Retry Countp.40ACK NAK Error Handlingp.41Indicate Transmission Failurep.42Disable Characterp.42Enable Characterp.43Keyboard Interfacep.45Country Modep.45Caps Lock Statep.48Numlockp.48Keyboard Numeric Keypadp.49Keyboard Send Control Charactersp.50Wedge Quiet Intervalp.51Intercharacter Delayp.52Intercode Delayp.53USB Keyboard Speedp.54USB-OEM Interfacep.57Introductionp.57Standard Factory Settingsp.57USB-OEM Device Usagep.58USB-OEM Interface Optionsp.58Wand Emulation Interfacep.59Wand Signal Speedp.59Wand Polarityp.60Wand Idle Statep.60Transmit Noisep.61Label Symbology Conversionp.62Data Formatp.63Global Prefix/Suffixp.64Global AIM IDp.65GS1-128 AIM IDp.65Label IDp.66Label ID: Pre-loaded Setsp.66Label ID: Set Individually Per Symbologyp.67Label ID Controlp.67Label ID Symbology Selectionp.68Set Global Mid Label ID Character(s)p.74Case Conversionp.75Character Conversionp.76Reading Parametersp.77Double Read Timeoutp.78Label Gone Timeoutp.80Power Save Modep.81Sleep Mode Timeoutp.82LED and Beeper Indicatorsp.83Power On Alertp.83Good Read: When to Indicatep.84Good Read Beep Typep.85Good Read Beep Frequencyp.85Good Read Beep Volumep.86Good Read Beep Lengthp.87Illumination Controlp.88Good Read LED Durationp.89Scanning Featuresp.90Scan Modep.90Stand Mode Triggered Timeoutp.91Scanning Active Timep.93Stand Mode Flashp.93Flash On Timep.94Flash Off Timep.94Stand Mode Sensitivityp.95Symbologiesp.97Introductionp.97Standard Factory Settings for Symbologiesp.97Disable All Symbologiesp.98Coupon Controlp.98UPC-Ap.99UPC-A Enable/Disablep.99UPC-A Check Character Transmissionp.99Expand UPC-A to EAN-13p.100UPC-A Number System Character Transmissionp.100In-Store Minimum Readsp.101UPC-Ep.102UPC-E Enable/Disablep.102UPC-E Check Character Transmissionp.102Expand UPC-E to EAN-13p.103Expand UPC-E to UPC-Ap.103UPC-E Number System Character Transmissionp.104UPC-E Minimum Readp.104EAN 13p.105EAN 13 Enable/Disablep.105EAN 13 Check Character Transmissionp.105EAN-13 Flag 1 Characterp.106EAN-13 ISBN Conversionp.106ISSN Enable/Disablep.107EAN 13 Minimum Readsp.107EAN 8p.108EAN 8 Enable/Disablep.108EAN 8 Check Character Transmissionp.108Expand EAN 8 to EAN 13p.109EAN 8 Both Guards Substitutionp.109EAN 8 Guard Insertionp.110EAN 8 Guard Substitutionp.110EAN 8 Minimum Segment Length Blockp.111EAN 8 Minimum Readsp.113EAN 8 Stitch Exact Label Halvesp.114EAN 8 Stitch Unlike Label Halvesp.114EAN Two Labelp.115EAN Two Label Enable/Disablep.115EAN Two Label Combined Transmissionp.115EAN Two Label Minimum Readsp.116UPC/EAN Global Settingsp.117UPC/EAN Decoding Levelp.117UPC/EAN Correlationp.118UPC/EAN Price Weight Checkp.119UPC-A Minimum Readsp.120UPC/EAN Guard Insertionp.121UPC/EAN Stitch Exact Label Halvesp.121UPC/EAN Stitch Unlike Label Halvesp.122UPC/EAN Minimum Segment Lengthp.123Add-Onsp.125Optional Add-onsp.125Optional Add-On Timerp.127P2 Add-Ons Minimum Readsp.129P5 Add-Ons Minimum Readsp.130GS1-128 Add-Ons Minimum Readsp.131GS1 DataBarTM Omnidirectionalp.132GS1 DataBar Omnidirectional Enable/Disablep.132GS1 DataBar Omnidirectional GS1-128 Emulationp.132GS1 DataBar Omnidirectional Minimum Readsp.133GS1 DataBarTM Expandedp.134GS1 DataBar Expanded Enable/Disablep.134GS1 DataBar Expanded GS1-128 Emulationp.134GS1 DataBar Expanded Minimum Readsp.135GS1 DataBar Expanded Length Controlp.136GS1 DataBar Expanded Set Length 1p.136GS1 DataBar Expanded Set Length 2p.137GS1 DataBarTM Limitedp.138GS1 DataBar Limited Enable/Disablep.138GS1 DataBar Limited GS1-128 Emulationp.138GS1 DataBar Limited Minimum Readsp.139Code 39p.140Code 39 Enable/Disablep.140Code 39 Check Character Calculationp.141Code 39 Check Character Transmissionp.142Code 39 Start/Stop Character Transmissionp.142Code 39 Full ASCIIp.143Code 39 Quiet Zonesp.144Code 39 Minimum Readsp.145Code 39 Decoding Levelp.146Code 39 Length Controlp.147Code 39 Set Length 1p.148Code 39 Set Length 2p.149Code 39 Interdigit Ratiop.150Code 39 Character Correlationp.152Code 39 Stitchingp.152Code 32 (Italian Pharmaceutical)p.153Code 32 Enable/Disablep.153Code 32 Feature Setting Exceptionsp.153Code 32 Check Character Transmissionp.154Code 32 Start/Stop Character Transmissionp.154Code 39 CIP (French Pharmaceutical)p.155Code 39 CIP Enable/Disablep.155Code 128p.155Code 128 Enable/Disablep.155Expand Code 128 to Code 39p.156Code 128 Check Character Transmissionp.156Code 128 Function Character Transmissionp.157Code 128 Sub-Code Change Transmissionp.157Code 128 Quiet Zonesp.158Code 128 Minimum Readsp.159Code 128 Decoding Levelp.160Code 128 Length Controlp.161Code 128 Set Length 1p.162Code 128 Set Length 2p.163Code 128 Character Correlationp.164Code 128 Stitchingp.164GS1-128p.165GS1-128 Enablep.165Interleaved 2 of 5 (I 2 of 5)p.166I 2 of 5 Enable/Disablep.166I 2 of 5 Check Character Calculationp.167I 2 of 5 Check Character Transmissionp.168I 2 of 5 Minimum Readsp.169I 2 of 5 Decoding Levelp.170I 2 of 5 Length Controlp.171I 2 of 5 Set Length 1p.172I 2 of 5 Set Length 2p.173I 2 of 5 Character Correlationp.174I 2 of 5 Zero Patternp.174I 2 of 5 Stitchingp.175Interleaved 2 of 5 CIP HRp.175Interleaved 2 of 5 CIP HR Enable/Disablep.175Datalogic 2 of 5p.176Datalogic 2 of 5 Enable/Disablep.176Datalogic 2 of 5 Check Character Calculationp.176Datalogic 2 of 5 Check Character Transmissionp.177Datalogic 2 of 5 Minimum Readsp.177Datalogic 2 of 5 Decoding Levelp.178Datalogic 2 of 5 Length Controlp.178Datalogic 2 of 5 Set Length 1p.179Datalogic 2 of 5 Set Length 2p.180Datalogic 2 of 5 Interdigit Ratiop.181Datalogic 2 of 5 Character Correlationp.183Datalogic 2 of 5 Stitchingp.183Codabarp.184Codabar Enable/Disablep.184Codabar Check Character Calculationp.184Codabar Check Character Transmissionp.185Codabar Start/Stop Character Transmissionp.185Codabar Start/Stop Character Setp.186Codabar Start/Stop Character Matchp.187Codabar Quiet Zonesp.188Codabar Minimum Readsp.189Codabar Decoding Levelp.190Codabar Length Controlp.191Codabar Set Length 1p.192Codabar Set Length 2p.193Codabar Interdigit Ratiop.194Codabar Character Correlationp.196Codabar Stitchingp.196ABC Codabarp.197ABC Codabar Enable/Disablep.197ABC Codabar Concatenation Modep.197ABC Codabar Dynamic Concatenation Timeoutp.198ABC Codabar Force Concatenationp.198Code 11p.199Code 11 Enable/Disablep.199Code 11 Check Character Calculationp.200Code 11 Check Character Transmissionp.200Code 11 Minimum Readsp.201Code 11 Length Controlp.202Code 11 Set Length 1p.202Code 11 Set Length 2p.203Code 11 Interdigit Ratiop.204Code 11 Decoding Levelp.206Code 11 Character Correlationp.207Code 11 Stitchingp.207Standard 2 of 5p.208Standard 2 of 5 Enable/Disablep.208Standard 2 of 5 Check Character Calculationp.208Standard 2 of 5 Check Character Transmissionp.209Standard 2 of 5 Minimum Readsp.209Standard 2 of 5 Decoding Levelp.210Standard 2 of 5 Length Controlp.210Standard 2 of 5 Set Length 1p.211Standard 2 of 5 Set Length 2p.212Standard 2 of 5 Character Correlationp.213Standard 2 of 5 Stitchingp.213Industrial 2 of 5p.214Industrial 2 of 5 Enable/Disablep.214Industrial 2 of 5 Check Character Calculationp.214Industrial 2 of 5 Check Character Transmissionp.215Industrial 2 of 5 Length Controlp.215Industrial 2 of 5 Set Length 1p.216Industrial 2 of 5 Set Length 2p.217Industrial 2 of 5 Minimum Readsp.218Industrial 2 of 5 Stitchingp.219Industrial 2 of 5 Character Correlationp.219IATAp.220IATA Enable/Disablep.220IATA Check Character Transmissionp.220ISBT 128p.221ISBT 128 Concatenationp.221ISBT 128 Concatenation Modep.221ISBT 128 Dynamic Concatenation Timeoutp.222ISBT 128 Force Concatenationp.223ISBT 128 Advanced Concatenation Optionsp.223MSIp.224MSI Enable/Disablep.224MSI Check Character Calculationp.224MSI Check Character Transmissionp.225MSI Length Controlp.225MSI Set Length 1p.226MSI Set Length 2p.227MSI Minimum Readsp.228MSI Decoding Levelp.229Code 93p.230Code 93 Enable/Disablep.230Code 93 Check Character Calculationp.230Code 93 Check Character Transmissionp.231Code 93 Length Controlp.231Code 93 Set Length 1p.232Code 93 Set Length 2p.233Code 93 Minimum Readsp.234Code 93 Decoding Levelp.235Code 93 Quiet Zonesp.236Code 93 Stitchingp.237Code 93 Character Correlationp.237Codablock Fp.238Codablock F Enable/Disablep.238Codablock F EAN Enable/Disablep.238Codablock F AIM Checkp.239Codablock F Length Controlp.239Codablock F Set Length 1p.240Codablock F Set Length 2p.241Code 4p.242Code 4 Enable/Disablep.242Code 4 Check Character Transmissionp.242Code 4 Hex to Decimal Conversionp.243Code 5p.243Code 5 Enable/Disablep.243Code 5 Check Character Transmissionp.244Code 5 Hex to Decimal Conversionp.244Code 4 and Code 5 Common Configuration Itemsp.245Code 4 and 5 Decoding Levelp.245Code 4 and Code 5 Minimum Readsp.246Follett 2 of 5p.247Follett 2 of 5 Enable/Disablep.247BC412p.247BC412 Enable/Disablep.247BC412 Check Character Calculationp.248BC412 Minimum Readsp.248BC412 Decoding Levelp.249BC412 Length Controlp.250BC412 Set Length 1p.250BC412 Set Length 2p.251Plesseyp.252Plessey Enable/Disablep.252Plessey Check Character Calculationp.253Plessey Check Character Transmissionp.254Plessey Length Controlp.254Plessey Set Length 1p.255Plessey Set Length 2p.256Plessey Minimum Readsp.257Plessey Decoding Levelp.258Plessey Stitchingp.259Plessey Character Correlationp.259Referencesp.261RS-232 Parametersp.262RS-232 Onlyp.262RS-232/USB COM Parametersp.263Keyboard Interfacep.270Wedge Quiet Intervalp.270Intercharacter Delayp.271Intercode Delayp.272Data Formatp.273Data Editingp.273Global Prefix/Suffixp.274Global AIM IDp.275Label IDp.276Set Global Mid Label ID Character(s)p.280Character Conversionp.280Reading Parametersp.282Label Gone Timeoutp.282Good Read LED Durationp.283Scanning Featuresp.284Scan Modep.284Scanning Active Timep.285Flash On Timep.286Flash Off Timep.287Symbologiesp.288Decoding Levelsp.288Set Lengthp.288Technical Specificationsp.291Standard Cable Pinoutsp.293LED and Beeper Indicationsp.294Error Codesp.295Standard Defaultsp.297Default Exceptionsp.308Sample Bar Codesp.3111D Bar Codesp.311GS1 DataBar (RSS)p.313GS1 DataBar-14p.313Keypadp.315Scancode Tablesp.319Control Character Emulationp.319Interface Type PC AT PS/2 or USB-Keyboardp.320Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Modep.322Digital Interfacep.324IBM XTp.326Microsoft Windows Codepage 1252p.328ASCII Chartp.331
Page 7 of the Solis 842 user manual — Table of contents
Page 7 · click to enlarge
Page 7

Table of contents

Introductionp.11About the Touch TD1100p.11About this Manualp.11Overviewp.11Conventionsp.12Technical Supportp.12Datalogic Website Supportp.12Reseller Technical Supportp.12Telephone Technical Supportp.13Setupp.15Unpackingp.15Setting Up the Readerp.15Install the Interface Cablep.15Connect Host Interfacep.17Holder/Hands-Free Standp.18Interface Selectionp.19Configuring the Interfacep.19Customizing Configuration Settingsp.22Using the Programming Bar Codesp.22Interface Settingsp.23Configuring Other Featuresp.23Software Version Transmissionp.23Configuration Using Bar Codesp.25Configuration Parametersp.25Host Commands — Obey/Ignorep.27USB Suspend Modep.28RS-232 Only Interfacep.29RS-232 Standard Factory Settingsp.29Baud Ratep.29Data Bitsp.31Stop Bitsp.31Parityp.32Handshaking Controlp.33RS-232/USB-Com Interfacesp.35Standard Factory Settingsp.35Intercharacter Delayp.35Beep On ASCII BELp.36Beep On Not on Filep.36ACK NAK Optionsp.37ACK Characterp.38NAK Characterp.38ACK NAK Timeout Valuep.39ACK NAK Retry Countp.40ACK NAK Error Handlingp.41Indicate Transmission Failurep.42Disable Characterp.42Enable Characterp.43Keyboard Interfacep.45Country Modep.45Caps Lock Statep.48Numlockp.48Keyboard Numeric Keypadp.49Keyboard Send Control Charactersp.50Wedge Quiet Intervalp.51Intercharacter Delayp.52Intercode Delayp.53USB Keyboard Speedp.54USB-OEM Interfacep.57Introductionp.57Standard Factory Settingsp.57USB-OEM Device Usagep.58USB-OEM Interface Optionsp.58Wand Emulation Interfacep.59Wand Signal Speedp.59Wand Polarityp.60Wand Idle Statep.60Transmit Noisep.61Label Symbology Conversionp.62Data Formatp.63Global Prefix/Suffixp.64Global AIM IDp.65GS1-128 AIM IDp.65Label IDp.66Label ID: Pre-loaded Setsp.66Label ID: Set Individually Per Symbologyp.67Label ID Controlp.67Label ID Symbology Selectionp.68Set Global Mid Label ID Character(s)p.74Case Conversionp.75Character Conversionp.76Reading Parametersp.77Double Read Timeoutp.78Label Gone Timeoutp.80Power Save Modep.81Sleep Mode Timeoutp.82LED and Beeper Indicatorsp.83Power On Alertp.83Good Read: When to Indicatep.84Good Read Beep Typep.85Good Read Beep Frequencyp.85Good Read Beep Volumep.86Good Read Beep Lengthp.87Illumination Controlp.88Good Read LED Durationp.89Scanning Featuresp.90Scan Modep.90Stand Mode Triggered Timeoutp.91Scanning Active Timep.93Stand Mode Flashp.93Flash On Timep.94Flash Off Timep.94Stand Mode Sensitivityp.95Symbologiesp.97Introductionp.97Standard Factory Settings for Symbologiesp.97Disable All Symbologiesp.98Coupon Controlp.98UPC-Ap.99UPC-A Enable/Disablep.99UPC-A Check Character Transmissionp.99Expand UPC-A to EAN-13p.100UPC-A Number System Character Transmissionp.100In-Store Minimum Readsp.101UPC-Ep.102UPC-E Enable/Disablep.102UPC-E Check Character Transmissionp.102Expand UPC-E to EAN-13p.103Expand UPC-E to UPC-Ap.103UPC-E Number System Character Transmissionp.104UPC-E Minimum Readp.104EAN 13p.105EAN 13 Enable/Disablep.105EAN 13 Check Character Transmissionp.105EAN-13 Flag 1 Characterp.106EAN-13 ISBN Conversionp.106ISSN Enable/Disablep.107EAN 13 Minimum Readsp.107EAN 8p.108EAN 8 Enable/Disablep.108EAN 8 Check Character Transmissionp.108Expand EAN 8 to EAN 13p.109EAN 8 Both Guards Substitutionp.109EAN 8 Guard Insertionp.110EAN 8 Guard Substitutionp.110EAN 8 Minimum Segment Length Blockp.111EAN 8 Minimum Readsp.113EAN 8 Stitch Exact Label Halvesp.114EAN 8 Stitch Unlike Label Halvesp.114EAN Two Labelp.115EAN Two Label Enable/Disablep.115EAN Two Label Combined Transmissionp.115EAN Two Label Minimum Readsp.116UPC/EAN Global Settingsp.117UPC/EAN Decoding Levelp.117UPC/EAN Correlationp.118UPC/EAN Price Weight Checkp.119UPC-A Minimum Readsp.120UPC/EAN Guard Insertionp.121UPC/EAN Stitch Exact Label Halvesp.121UPC/EAN Stitch Unlike Label Halvesp.122UPC/EAN Minimum Segment Lengthp.123Add-Onsp.125Optional Add-onsp.125Optional Add-On Timerp.127P2 Add-Ons Minimum Readsp.129P5 Add-Ons Minimum Readsp.130GS1-128 Add-Ons Minimum Readsp.131GS1 DataBarTM Omnidirectionalp.132GS1 DataBar Omnidirectional Enable/Disablep.132GS1 DataBar Omnidirectional GS1-128 Emulationp.132GS1 DataBar Omnidirectional Minimum Readsp.133GS1 DataBarTM Expandedp.134GS1 DataBar Expanded Enable/Disablep.134GS1 DataBar Expanded GS1-128 Emulationp.134GS1 DataBar Expanded Minimum Readsp.135GS1 DataBar Expanded Length Controlp.136GS1 DataBar Expanded Set Length 1p.136GS1 DataBar Expanded Set Length 2p.137GS1 DataBarTM Limitedp.138GS1 DataBar Limited Enable/Disablep.138GS1 DataBar Limited GS1-128 Emulationp.138GS1 DataBar Limited Minimum Readsp.139Code 39p.140Code 39 Enable/Disablep.140Code 39 Check Character Calculationp.141Code 39 Check Character Transmissionp.142Code 39 Start/Stop Character Transmissionp.142Code 39 Full ASCIIp.143Code 39 Quiet Zonesp.144Code 39 Minimum Readsp.145Code 39 Decoding Levelp.146Code 39 Length Controlp.147Code 39 Set Length 1p.148Code 39 Set Length 2p.149Code 39 Interdigit Ratiop.150Code 39 Character Correlationp.152Code 39 Stitchingp.152Code 32 (Italian Pharmaceutical)p.153Code 32 Enable/Disablep.153Code 32 Feature Setting Exceptionsp.153Code 32 Check Character Transmissionp.154Code 32 Start/Stop Character Transmissionp.154Code 39 CIP (French Pharmaceutical)p.155Code 39 CIP Enable/Disablep.155Code 128p.155Code 128 Enable/Disablep.155Expand Code 128 to Code 39p.156Code 128 Check Character Transmissionp.156Code 128 Function Character Transmissionp.157Code 128 Sub-Code Change Transmissionp.157Code 128 Quiet Zonesp.158Code 128 Minimum Readsp.159Code 128 Decoding Levelp.160Code 128 Length Controlp.161Code 128 Set Length 1p.162Code 128 Set Length 2p.163Code 128 Character Correlationp.164Code 128 Stitchingp.164GS1-128p.165GS1-128 Enablep.165Interleaved 2 of 5 (I 2 of 5)p.166I 2 of 5 Enable/Disablep.166I 2 of 5 Check Character Calculationp.167I 2 of 5 Check Character Transmissionp.168I 2 of 5 Minimum Readsp.169I 2 of 5 Decoding Levelp.170I 2 of 5 Length Controlp.171I 2 of 5 Set Length 1p.172I 2 of 5 Set Length 2p.173I 2 of 5 Character Correlationp.174I 2 of 5 Zero Patternp.174I 2 of 5 Stitchingp.175Interleaved 2 of 5 CIP HRp.175Interleaved 2 of 5 CIP HR Enable/Disablep.175Datalogic 2 of 5p.176Datalogic 2 of 5 Enable/Disablep.176Datalogic 2 of 5 Check Character Calculationp.176Datalogic 2 of 5 Check Character Transmissionp.177Datalogic 2 of 5 Minimum Readsp.177Datalogic 2 of 5 Decoding Levelp.178Datalogic 2 of 5 Length Controlp.178Datalogic 2 of 5 Set Length 1p.179Datalogic 2 of 5 Set Length 2p.180Datalogic 2 of 5 Interdigit Ratiop.181Datalogic 2 of 5 Character Correlationp.183Datalogic 2 of 5 Stitchingp.183Codabarp.184Codabar Enable/Disablep.184Codabar Check Character Calculationp.184Codabar Check Character Transmissionp.185Codabar Start/Stop Character Transmissionp.185Codabar Start/Stop Character Setp.186Codabar Start/Stop Character Matchp.187Codabar Quiet Zonesp.188Codabar Minimum Readsp.189Codabar Decoding Levelp.190Codabar Length Controlp.191Codabar Set Length 1p.192Codabar Set Length 2p.193Codabar Interdigit Ratiop.194Codabar Character Correlationp.196Codabar Stitchingp.196ABC Codabarp.197ABC Codabar Enable/Disablep.197ABC Codabar Concatenation Modep.197ABC Codabar Dynamic Concatenation Timeoutp.198ABC Codabar Force Concatenationp.198Code 11p.199Code 11 Enable/Disablep.199Code 11 Check Character Calculationp.200Code 11 Check Character Transmissionp.200Code 11 Minimum Readsp.201Code 11 Length Controlp.202Code 11 Set Length 1p.202Code 11 Set Length 2p.203Code 11 Interdigit Ratiop.204Code 11 Decoding Levelp.206Code 11 Character Correlationp.207Code 11 Stitchingp.207Standard 2 of 5p.208Standard 2 of 5 Enable/Disablep.208Standard 2 of 5 Check Character Calculationp.208Standard 2 of 5 Check Character Transmissionp.209Standard 2 of 5 Minimum Readsp.209Standard 2 of 5 Decoding Levelp.210Standard 2 of 5 Length Controlp.210Standard 2 of 5 Set Length 1p.211Standard 2 of 5 Set Length 2p.212Standard 2 of 5 Character Correlationp.213Standard 2 of 5 Stitchingp.213Industrial 2 of 5p.214Industrial 2 of 5 Enable/Disablep.214Industrial 2 of 5 Check Character Calculationp.214Industrial 2 of 5 Check Character Transmissionp.215Industrial 2 of 5 Length Controlp.215Industrial 2 of 5 Set Length 1p.216Industrial 2 of 5 Set Length 2p.217Industrial 2 of 5 Minimum Readsp.218Industrial 2 of 5 Stitchingp.219Industrial 2 of 5 Character Correlationp.219IATAp.220IATA Enable/Disablep.220IATA Check Character Transmissionp.220ISBT 128p.221ISBT 128 Concatenationp.221ISBT 128 Concatenation Modep.221ISBT 128 Dynamic Concatenation Timeoutp.222ISBT 128 Force Concatenationp.223ISBT 128 Advanced Concatenation Optionsp.223MSIp.224MSI Enable/Disablep.224MSI Check Character Calculationp.224MSI Check Character Transmissionp.225MSI Length Controlp.225MSI Set Length 1p.226MSI Set Length 2p.227MSI Minimum Readsp.228MSI Decoding Levelp.229Code 93p.230Code 93 Enable/Disablep.230Code 93 Check Character Calculationp.230Code 93 Check Character Transmissionp.231Code 93 Length Controlp.231Code 93 Set Length 1p.232Code 93 Set Length 2p.233Code 93 Minimum Readsp.234Code 93 Decoding Levelp.235Code 93 Quiet Zonesp.236Code 93 Stitchingp.237Code 93 Character Correlationp.237Codablock Fp.238Codablock F Enable/Disablep.238Codablock F EAN Enable/Disablep.238Codablock F AIM Checkp.239Codablock F Length Controlp.239Codablock F Set Length 1p.240Codablock F Set Length 2p.241Code 4p.242Code 4 Enable/Disablep.242Code 4 Check Character Transmissionp.242Code 4 Hex to Decimal Conversionp.243Code 5p.243Code 5 Enable/Disablep.243Code 5 Check Character Transmissionp.244Code 5 Hex to Decimal Conversionp.244Code 4 and Code 5 Common Configuration Itemsp.245Code 4 and 5 Decoding Levelp.245Code 4 and Code 5 Minimum Readsp.246Follett 2 of 5p.247Follett 2 of 5 Enable/Disablep.247BC412p.247BC412 Enable/Disablep.247BC412 Check Character Calculationp.248BC412 Minimum Readsp.248BC412 Decoding Levelp.249BC412 Length Controlp.250BC412 Set Length 1p.250BC412 Set Length 2p.251Plesseyp.252Plessey Enable/Disablep.252Plessey Check Character Calculationp.253Plessey Check Character Transmissionp.254Plessey Length Controlp.254Plessey Set Length 1p.255Plessey Set Length 2p.256Plessey Minimum Readsp.257Plessey Decoding Levelp.258Plessey Stitchingp.259Plessey Character Correlationp.259Referencesp.261RS-232 Parametersp.262RS-232 Onlyp.262RS-232/USB COM Parametersp.263Keyboard Interfacep.270Wedge Quiet Intervalp.270Intercharacter Delayp.271Intercode Delayp.272Data Formatp.273Data Editingp.273Global Prefix/Suffixp.274Global AIM IDp.275Label IDp.276Set Global Mid Label ID Character(s)p.280Character Conversionp.280Reading Parametersp.282Label Gone Timeoutp.282Good Read LED Durationp.283Scanning Featuresp.284Scan Modep.284Scanning Active Timep.285Flash On Timep.286Flash Off Timep.287Symbologiesp.288Decoding Levelsp.288Set Lengthp.288Technical Specificationsp.291Standard Cable Pinoutsp.293LED and Beeper Indicationsp.294Error Codesp.295Standard Defaultsp.297Default Exceptionsp.308Sample Bar Codesp.3111D Bar Codesp.311GS1 DataBar (RSS)p.313GS1 DataBar-14p.313Keypadp.315Scancode Tablesp.319Control Character Emulationp.319Interface Type PC AT PS/2 or USB-Keyboardp.320Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Modep.322Digital Interfacep.324IBM XTp.326Microsoft Windows Codepage 1252p.328ASCII Chartp.331
Page 8 of the Solis 842 user manual — Table of contents
Page 8 · click to enlarge
Page 8

Table of contents

Introductionp.11About the Touch TD1100p.11About this Manualp.11Overviewp.11Conventionsp.12Technical Supportp.12Datalogic Website Supportp.12Reseller Technical Supportp.12Telephone Technical Supportp.13Setupp.15Unpackingp.15Setting Up the Readerp.15Install the Interface Cablep.15Connect Host Interfacep.17Holder/Hands-Free Standp.18Interface Selectionp.19Configuring the Interfacep.19Customizing Configuration Settingsp.22Using the Programming Bar Codesp.22Interface Settingsp.23Configuring Other Featuresp.23Software Version Transmissionp.23Configuration Using Bar Codesp.25Configuration Parametersp.25Host Commands — Obey/Ignorep.27USB Suspend Modep.28RS-232 Only Interfacep.29RS-232 Standard Factory Settingsp.29Baud Ratep.29Data Bitsp.31Stop Bitsp.31Parityp.32Handshaking Controlp.33RS-232/USB-Com Interfacesp.35Standard Factory Settingsp.35Intercharacter Delayp.35Beep On ASCII BELp.36Beep On Not on Filep.36ACK NAK Optionsp.37ACK Characterp.38NAK Characterp.38ACK NAK Timeout Valuep.39ACK NAK Retry Countp.40ACK NAK Error Handlingp.41Indicate Transmission Failurep.42Disable Characterp.42Enable Characterp.43Keyboard Interfacep.45Country Modep.45Caps Lock Statep.48Numlockp.48Keyboard Numeric Keypadp.49Keyboard Send Control Charactersp.50Wedge Quiet Intervalp.51Intercharacter Delayp.52Intercode Delayp.53USB Keyboard Speedp.54USB-OEM Interfacep.57Introductionp.57Standard Factory Settingsp.57USB-OEM Device Usagep.58USB-OEM Interface Optionsp.58Wand Emulation Interfacep.59Wand Signal Speedp.59Wand Polarityp.60Wand Idle Statep.60Transmit Noisep.61Label Symbology Conversionp.62Data Formatp.63Global Prefix/Suffixp.64Global AIM IDp.65GS1-128 AIM IDp.65Label IDp.66Label ID: Pre-loaded Setsp.66Label ID: Set Individually Per Symbologyp.67Label ID Controlp.67Label ID Symbology Selectionp.68Set Global Mid Label ID Character(s)p.74Case Conversionp.75Character Conversionp.76Reading Parametersp.77Double Read Timeoutp.78Label Gone Timeoutp.80Power Save Modep.81Sleep Mode Timeoutp.82LED and Beeper Indicatorsp.83Power On Alertp.83Good Read: When to Indicatep.84Good Read Beep Typep.85Good Read Beep Frequencyp.85Good Read Beep Volumep.86Good Read Beep Lengthp.87Illumination Controlp.88Good Read LED Durationp.89Scanning Featuresp.90Scan Modep.90Stand Mode Triggered Timeoutp.91Scanning Active Timep.93Stand Mode Flashp.93Flash On Timep.94Flash Off Timep.94Stand Mode Sensitivityp.95Symbologiesp.97Introductionp.97Standard Factory Settings for Symbologiesp.97Disable All Symbologiesp.98Coupon Controlp.98UPC-Ap.99UPC-A Enable/Disablep.99UPC-A Check Character Transmissionp.99Expand UPC-A to EAN-13p.100UPC-A Number System Character Transmissionp.100In-Store Minimum Readsp.101UPC-Ep.102UPC-E Enable/Disablep.102UPC-E Check Character Transmissionp.102Expand UPC-E to EAN-13p.103Expand UPC-E to UPC-Ap.103UPC-E Number System Character Transmissionp.104UPC-E Minimum Readp.104EAN 13p.105EAN 13 Enable/Disablep.105EAN 13 Check Character Transmissionp.105EAN-13 Flag 1 Characterp.106EAN-13 ISBN Conversionp.106ISSN Enable/Disablep.107EAN 13 Minimum Readsp.107EAN 8p.108EAN 8 Enable/Disablep.108EAN 8 Check Character Transmissionp.108Expand EAN 8 to EAN 13p.109EAN 8 Both Guards Substitutionp.109EAN 8 Guard Insertionp.110EAN 8 Guard Substitutionp.110EAN 8 Minimum Segment Length Blockp.111EAN 8 Minimum Readsp.113EAN 8 Stitch Exact Label Halvesp.114EAN 8 Stitch Unlike Label Halvesp.114EAN Two Labelp.115EAN Two Label Enable/Disablep.115EAN Two Label Combined Transmissionp.115EAN Two Label Minimum Readsp.116UPC/EAN Global Settingsp.117UPC/EAN Decoding Levelp.117UPC/EAN Correlationp.118UPC/EAN Price Weight Checkp.119UPC-A Minimum Readsp.120UPC/EAN Guard Insertionp.121UPC/EAN Stitch Exact Label Halvesp.121UPC/EAN Stitch Unlike Label Halvesp.122UPC/EAN Minimum Segment Lengthp.123Add-Onsp.125Optional Add-onsp.125Optional Add-On Timerp.127P2 Add-Ons Minimum Readsp.129P5 Add-Ons Minimum Readsp.130GS1-128 Add-Ons Minimum Readsp.131GS1 DataBarTM Omnidirectionalp.132GS1 DataBar Omnidirectional Enable/Disablep.132GS1 DataBar Omnidirectional GS1-128 Emulationp.132GS1 DataBar Omnidirectional Minimum Readsp.133GS1 DataBarTM Expandedp.134GS1 DataBar Expanded Enable/Disablep.134GS1 DataBar Expanded GS1-128 Emulationp.134GS1 DataBar Expanded Minimum Readsp.135GS1 DataBar Expanded Length Controlp.136GS1 DataBar Expanded Set Length 1p.136GS1 DataBar Expanded Set Length 2p.137GS1 DataBarTM Limitedp.138GS1 DataBar Limited Enable/Disablep.138GS1 DataBar Limited GS1-128 Emulationp.138GS1 DataBar Limited Minimum Readsp.139Code 39p.140Code 39 Enable/Disablep.140Code 39 Check Character Calculationp.141Code 39 Check Character Transmissionp.142Code 39 Start/Stop Character Transmissionp.142Code 39 Full ASCIIp.143Code 39 Quiet Zonesp.144Code 39 Minimum Readsp.145Code 39 Decoding Levelp.146Code 39 Length Controlp.147Code 39 Set Length 1p.148Code 39 Set Length 2p.149Code 39 Interdigit Ratiop.150Code 39 Character Correlationp.152Code 39 Stitchingp.152Code 32 (Italian Pharmaceutical)p.153Code 32 Enable/Disablep.153Code 32 Feature Setting Exceptionsp.153Code 32 Check Character Transmissionp.154Code 32 Start/Stop Character Transmissionp.154Code 39 CIP (French Pharmaceutical)p.155Code 39 CIP Enable/Disablep.155Code 128p.155Code 128 Enable/Disablep.155Expand Code 128 to Code 39p.156Code 128 Check Character Transmissionp.156Code 128 Function Character Transmissionp.157Code 128 Sub-Code Change Transmissionp.157Code 128 Quiet Zonesp.158Code 128 Minimum Readsp.159Code 128 Decoding Levelp.160Code 128 Length Controlp.161Code 128 Set Length 1p.162Code 128 Set Length 2p.163Code 128 Character Correlationp.164Code 128 Stitchingp.164GS1-128p.165GS1-128 Enablep.165Interleaved 2 of 5 (I 2 of 5)p.166I 2 of 5 Enable/Disablep.166I 2 of 5 Check Character Calculationp.167I 2 of 5 Check Character Transmissionp.168I 2 of 5 Minimum Readsp.169I 2 of 5 Decoding Levelp.170I 2 of 5 Length Controlp.171I 2 of 5 Set Length 1p.172I 2 of 5 Set Length 2p.173I 2 of 5 Character Correlationp.174I 2 of 5 Zero Patternp.174I 2 of 5 Stitchingp.175Interleaved 2 of 5 CIP HRp.175Interleaved 2 of 5 CIP HR Enable/Disablep.175Datalogic 2 of 5p.176Datalogic 2 of 5 Enable/Disablep.176Datalogic 2 of 5 Check Character Calculationp.176Datalogic 2 of 5 Check Character Transmissionp.177Datalogic 2 of 5 Minimum Readsp.177Datalogic 2 of 5 Decoding Levelp.178Datalogic 2 of 5 Length Controlp.178Datalogic 2 of 5 Set Length 1p.179Datalogic 2 of 5 Set Length 2p.180Datalogic 2 of 5 Interdigit Ratiop.181Datalogic 2 of 5 Character Correlationp.183Datalogic 2 of 5 Stitchingp.183Codabarp.184Codabar Enable/Disablep.184Codabar Check Character Calculationp.184Codabar Check Character Transmissionp.185Codabar Start/Stop Character Transmissionp.185Codabar Start/Stop Character Setp.186Codabar Start/Stop Character Matchp.187Codabar Quiet Zonesp.188Codabar Minimum Readsp.189Codabar Decoding Levelp.190Codabar Length Controlp.191Codabar Set Length 1p.192Codabar Set Length 2p.193Codabar Interdigit Ratiop.194Codabar Character Correlationp.196Codabar Stitchingp.196ABC Codabarp.197ABC Codabar Enable/Disablep.197ABC Codabar Concatenation Modep.197ABC Codabar Dynamic Concatenation Timeoutp.198ABC Codabar Force Concatenationp.198Code 11p.199Code 11 Enable/Disablep.199Code 11 Check Character Calculationp.200Code 11 Check Character Transmissionp.200Code 11 Minimum Readsp.201Code 11 Length Controlp.202Code 11 Set Length 1p.202Code 11 Set Length 2p.203Code 11 Interdigit Ratiop.204Code 11 Decoding Levelp.206Code 11 Character Correlationp.207Code 11 Stitchingp.207Standard 2 of 5p.208Standard 2 of 5 Enable/Disablep.208Standard 2 of 5 Check Character Calculationp.208Standard 2 of 5 Check Character Transmissionp.209Standard 2 of 5 Minimum Readsp.209Standard 2 of 5 Decoding Levelp.210Standard 2 of 5 Length Controlp.210Standard 2 of 5 Set Length 1p.211Standard 2 of 5 Set Length 2p.212Standard 2 of 5 Character Correlationp.213Standard 2 of 5 Stitchingp.213Industrial 2 of 5p.214Industrial 2 of 5 Enable/Disablep.214Industrial 2 of 5 Check Character Calculationp.214Industrial 2 of 5 Check Character Transmissionp.215Industrial 2 of 5 Length Controlp.215Industrial 2 of 5 Set Length 1p.216Industrial 2 of 5 Set Length 2p.217Industrial 2 of 5 Minimum Readsp.218Industrial 2 of 5 Stitchingp.219Industrial 2 of 5 Character Correlationp.219IATAp.220IATA Enable/Disablep.220IATA Check Character Transmissionp.220ISBT 128p.221ISBT 128 Concatenationp.221ISBT 128 Concatenation Modep.221ISBT 128 Dynamic Concatenation Timeoutp.222ISBT 128 Force Concatenationp.223ISBT 128 Advanced Concatenation Optionsp.223MSIp.224MSI Enable/Disablep.224MSI Check Character Calculationp.224MSI Check Character Transmissionp.225MSI Length Controlp.225MSI Set Length 1p.226MSI Set Length 2p.227MSI Minimum Readsp.228MSI Decoding Levelp.229Code 93p.230Code 93 Enable/Disablep.230Code 93 Check Character Calculationp.230Code 93 Check Character Transmissionp.231Code 93 Length Controlp.231Code 93 Set Length 1p.232Code 93 Set Length 2p.233Code 93 Minimum Readsp.234Code 93 Decoding Levelp.235Code 93 Quiet Zonesp.236Code 93 Stitchingp.237Code 93 Character Correlationp.237Codablock Fp.238Codablock F Enable/Disablep.238Codablock F EAN Enable/Disablep.238Codablock F AIM Checkp.239Codablock F Length Controlp.239Codablock F Set Length 1p.240Codablock F Set Length 2p.241Code 4p.242Code 4 Enable/Disablep.242Code 4 Check Character Transmissionp.242Code 4 Hex to Decimal Conversionp.243Code 5p.243Code 5 Enable/Disablep.243Code 5 Check Character Transmissionp.244Code 5 Hex to Decimal Conversionp.244Code 4 and Code 5 Common Configuration Itemsp.245Code 4 and 5 Decoding Levelp.245Code 4 and Code 5 Minimum Readsp.246Follett 2 of 5p.247Follett 2 of 5 Enable/Disablep.247BC412p.247BC412 Enable/Disablep.247BC412 Check Character Calculationp.248BC412 Minimum Readsp.248BC412 Decoding Levelp.249BC412 Length Controlp.250BC412 Set Length 1p.250BC412 Set Length 2p.251Plesseyp.252Plessey Enable/Disablep.252Plessey Check Character Calculationp.253Plessey Check Character Transmissionp.254Plessey Length Controlp.254Plessey Set Length 1p.255Plessey Set Length 2p.256Plessey Minimum Readsp.257Plessey Decoding Levelp.258Plessey Stitchingp.259Plessey Character Correlationp.259Referencesp.261RS-232 Parametersp.262RS-232 Onlyp.262RS-232/USB COM Parametersp.263Keyboard Interfacep.270Wedge Quiet Intervalp.270Intercharacter Delayp.271Intercode Delayp.272Data Formatp.273Data Editingp.273Global Prefix/Suffixp.274Global AIM IDp.275Label IDp.276Set Global Mid Label ID Character(s)p.280Character Conversionp.280Reading Parametersp.282Label Gone Timeoutp.282Good Read LED Durationp.283Scanning Featuresp.284Scan Modep.284Scanning Active Timep.285Flash On Timep.286Flash Off Timep.287Symbologiesp.288Decoding Levelsp.288Set Lengthp.288Technical Specificationsp.291Standard Cable Pinoutsp.293LED and Beeper Indicationsp.294Error Codesp.295Standard Defaultsp.297Default Exceptionsp.308Sample Bar Codesp.3111D Bar Codesp.311GS1 DataBar (RSS)p.313GS1 DataBar-14p.313Keypadp.315Scancode Tablesp.319Control Character Emulationp.319Interface Type PC AT PS/2 or USB-Keyboardp.320Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Modep.322Digital Interfacep.324IBM XTp.326Microsoft Windows Codepage 1252p.328ASCII Chartp.331
Page 9 of the Solis 842 user manual — Table of contents
Page 9 · click to enlarge
Page 9

Table of contents

Introductionp.11About the Touch TD1100p.11About this Manualp.11Overviewp.11Conventionsp.12Technical Supportp.12Datalogic Website Supportp.12Reseller Technical Supportp.12Telephone Technical Supportp.13Setupp.15Unpackingp.15Setting Up the Readerp.15Install the Interface Cablep.15Connect Host Interfacep.17Holder/Hands-Free Standp.18Interface Selectionp.19Configuring the Interfacep.19Customizing Configuration Settingsp.22Using the Programming Bar Codesp.22Interface Settingsp.23Configuring Other Featuresp.23Software Version Transmissionp.23Configuration Using Bar Codesp.25Configuration Parametersp.25Host Commands — Obey/Ignorep.27USB Suspend Modep.28RS-232 Only Interfacep.29RS-232 Standard Factory Settingsp.29Baud Ratep.29Data Bitsp.31Stop Bitsp.31Parityp.32Handshaking Controlp.33RS-232/USB-Com Interfacesp.35Standard Factory Settingsp.35Intercharacter Delayp.35Beep On ASCII BELp.36Beep On Not on Filep.36ACK NAK Optionsp.37ACK Characterp.38NAK Characterp.38ACK NAK Timeout Valuep.39ACK NAK Retry Countp.40ACK NAK Error Handlingp.41Indicate Transmission Failurep.42Disable Characterp.42Enable Characterp.43Keyboard Interfacep.45Country Modep.45Caps Lock Statep.48Numlockp.48Keyboard Numeric Keypadp.49Keyboard Send Control Charactersp.50Wedge Quiet Intervalp.51Intercharacter Delayp.52Intercode Delayp.53USB Keyboard Speedp.54USB-OEM Interfacep.57Introductionp.57Standard Factory Settingsp.57USB-OEM Device Usagep.58USB-OEM Interface Optionsp.58Wand Emulation Interfacep.59Wand Signal Speedp.59Wand Polarityp.60Wand Idle Statep.60Transmit Noisep.61Label Symbology Conversionp.62Data Formatp.63Global Prefix/Suffixp.64Global AIM IDp.65GS1-128 AIM IDp.65Label IDp.66Label ID: Pre-loaded Setsp.66Label ID: Set Individually Per Symbologyp.67Label ID Controlp.67Label ID Symbology Selectionp.68Set Global Mid Label ID Character(s)p.74Case Conversionp.75Character Conversionp.76Reading Parametersp.77Double Read Timeoutp.78Label Gone Timeoutp.80Power Save Modep.81Sleep Mode Timeoutp.82LED and Beeper Indicatorsp.83Power On Alertp.83Good Read: When to Indicatep.84Good Read Beep Typep.85Good Read Beep Frequencyp.85Good Read Beep Volumep.86Good Read Beep Lengthp.87Illumination Controlp.88Good Read LED Durationp.89Scanning Featuresp.90Scan Modep.90Stand Mode Triggered Timeoutp.91Scanning Active Timep.93Stand Mode Flashp.93Flash On Timep.94Flash Off Timep.94Stand Mode Sensitivityp.95Symbologiesp.97Introductionp.97Standard Factory Settings for Symbologiesp.97Disable All Symbologiesp.98Coupon Controlp.98UPC-Ap.99UPC-A Enable/Disablep.99UPC-A Check Character Transmissionp.99Expand UPC-A to EAN-13p.100UPC-A Number System Character Transmissionp.100In-Store Minimum Readsp.101UPC-Ep.102UPC-E Enable/Disablep.102UPC-E Check Character Transmissionp.102Expand UPC-E to EAN-13p.103Expand UPC-E to UPC-Ap.103UPC-E Number System Character Transmissionp.104UPC-E Minimum Readp.104EAN 13p.105EAN 13 Enable/Disablep.105EAN 13 Check Character Transmissionp.105EAN-13 Flag 1 Characterp.106EAN-13 ISBN Conversionp.106ISSN Enable/Disablep.107EAN 13 Minimum Readsp.107EAN 8p.108EAN 8 Enable/Disablep.108EAN 8 Check Character Transmissionp.108Expand EAN 8 to EAN 13p.109EAN 8 Both Guards Substitutionp.109EAN 8 Guard Insertionp.110EAN 8 Guard Substitutionp.110EAN 8 Minimum Segment Length Blockp.111EAN 8 Minimum Readsp.113EAN 8 Stitch Exact Label Halvesp.114EAN 8 Stitch Unlike Label Halvesp.114EAN Two Labelp.115EAN Two Label Enable/Disablep.115EAN Two Label Combined Transmissionp.115EAN Two Label Minimum Readsp.116UPC/EAN Global Settingsp.117UPC/EAN Decoding Levelp.117UPC/EAN Correlationp.118UPC/EAN Price Weight Checkp.119UPC-A Minimum Readsp.120UPC/EAN Guard Insertionp.121UPC/EAN Stitch Exact Label Halvesp.121UPC/EAN Stitch Unlike Label Halvesp.122UPC/EAN Minimum Segment Lengthp.123Add-Onsp.125Optional Add-onsp.125Optional Add-On Timerp.127P2 Add-Ons Minimum Readsp.129P5 Add-Ons Minimum Readsp.130GS1-128 Add-Ons Minimum Readsp.131GS1 DataBarTM Omnidirectionalp.132GS1 DataBar Omnidirectional Enable/Disablep.132GS1 DataBar Omnidirectional GS1-128 Emulationp.132GS1 DataBar Omnidirectional Minimum Readsp.133GS1 DataBarTM Expandedp.134GS1 DataBar Expanded Enable/Disablep.134GS1 DataBar Expanded GS1-128 Emulationp.134GS1 DataBar Expanded Minimum Readsp.135GS1 DataBar Expanded Length Controlp.136GS1 DataBar Expanded Set Length 1p.136GS1 DataBar Expanded Set Length 2p.137GS1 DataBarTM Limitedp.138GS1 DataBar Limited Enable/Disablep.138GS1 DataBar Limited GS1-128 Emulationp.138GS1 DataBar Limited Minimum Readsp.139Code 39p.140Code 39 Enable/Disablep.140Code 39 Check Character Calculationp.141Code 39 Check Character Transmissionp.142Code 39 Start/Stop Character Transmissionp.142Code 39 Full ASCIIp.143Code 39 Quiet Zonesp.144Code 39 Minimum Readsp.145Code 39 Decoding Levelp.146Code 39 Length Controlp.147Code 39 Set Length 1p.148Code 39 Set Length 2p.149Code 39 Interdigit Ratiop.150Code 39 Character Correlationp.152Code 39 Stitchingp.152Code 32 (Italian Pharmaceutical)p.153Code 32 Enable/Disablep.153Code 32 Feature Setting Exceptionsp.153Code 32 Check Character Transmissionp.154Code 32 Start/Stop Character Transmissionp.154Code 39 CIP (French Pharmaceutical)p.155Code 39 CIP Enable/Disablep.155Code 128p.155Code 128 Enable/Disablep.155Expand Code 128 to Code 39p.156Code 128 Check Character Transmissionp.156Code 128 Function Character Transmissionp.157Code 128 Sub-Code Change Transmissionp.157Code 128 Quiet Zonesp.158Code 128 Minimum Readsp.159Code 128 Decoding Levelp.160Code 128 Length Controlp.161Code 128 Set Length 1p.162Code 128 Set Length 2p.163Code 128 Character Correlationp.164Code 128 Stitchingp.164GS1-128p.165GS1-128 Enablep.165Interleaved 2 of 5 (I 2 of 5)p.166I 2 of 5 Enable/Disablep.166I 2 of 5 Check Character Calculationp.167I 2 of 5 Check Character Transmissionp.168I 2 of 5 Minimum Readsp.169I 2 of 5 Decoding Levelp.170I 2 of 5 Length Controlp.171I 2 of 5 Set Length 1p.172I 2 of 5 Set Length 2p.173I 2 of 5 Character Correlationp.174I 2 of 5 Zero Patternp.174I 2 of 5 Stitchingp.175Interleaved 2 of 5 CIP HRp.175Interleaved 2 of 5 CIP HR Enable/Disablep.175Datalogic 2 of 5p.176Datalogic 2 of 5 Enable/Disablep.176Datalogic 2 of 5 Check Character Calculationp.176Datalogic 2 of 5 Check Character Transmissionp.177Datalogic 2 of 5 Minimum Readsp.177Datalogic 2 of 5 Decoding Levelp.178Datalogic 2 of 5 Length Controlp.178Datalogic 2 of 5 Set Length 1p.179Datalogic 2 of 5 Set Length 2p.180Datalogic 2 of 5 Interdigit Ratiop.181Datalogic 2 of 5 Character Correlationp.183Datalogic 2 of 5 Stitchingp.183Codabarp.184Codabar Enable/Disablep.184Codabar Check Character Calculationp.184Codabar Check Character Transmissionp.185Codabar Start/Stop Character Transmissionp.185Codabar Start/Stop Character Setp.186Codabar Start/Stop Character Matchp.187Codabar Quiet Zonesp.188Codabar Minimum Readsp.189Codabar Decoding Levelp.190Codabar Length Controlp.191Codabar Set Length 1p.192Codabar Set Length 2p.193Codabar Interdigit Ratiop.194Codabar Character Correlationp.196Codabar Stitchingp.196ABC Codabarp.197ABC Codabar Enable/Disablep.197ABC Codabar Concatenation Modep.197ABC Codabar Dynamic Concatenation Timeoutp.198ABC Codabar Force Concatenationp.198Code 11p.199Code 11 Enable/Disablep.199Code 11 Check Character Calculationp.200Code 11 Check Character Transmissionp.200Code 11 Minimum Readsp.201Code 11 Length Controlp.202Code 11 Set Length 1p.202Code 11 Set Length 2p.203Code 11 Interdigit Ratiop.204Code 11 Decoding Levelp.206Code 11 Character Correlationp.207Code 11 Stitchingp.207Standard 2 of 5p.208Standard 2 of 5 Enable/Disablep.208Standard 2 of 5 Check Character Calculationp.208Standard 2 of 5 Check Character Transmissionp.209Standard 2 of 5 Minimum Readsp.209Standard 2 of 5 Decoding Levelp.210Standard 2 of 5 Length Controlp.210Standard 2 of 5 Set Length 1p.211Standard 2 of 5 Set Length 2p.212Standard 2 of 5 Character Correlationp.213Standard 2 of 5 Stitchingp.213Industrial 2 of 5p.214Industrial 2 of 5 Enable/Disablep.214Industrial 2 of 5 Check Character Calculationp.214Industrial 2 of 5 Check Character Transmissionp.215Industrial 2 of 5 Length Controlp.215Industrial 2 of 5 Set Length 1p.216Industrial 2 of 5 Set Length 2p.217Industrial 2 of 5 Minimum Readsp.218Industrial 2 of 5 Stitchingp.219Industrial 2 of 5 Character Correlationp.219IATAp.220IATA Enable/Disablep.220IATA Check Character Transmissionp.220ISBT 128p.221ISBT 128 Concatenationp.221ISBT 128 Concatenation Modep.221ISBT 128 Dynamic Concatenation Timeoutp.222ISBT 128 Force Concatenationp.223ISBT 128 Advanced Concatenation Optionsp.223MSIp.224MSI Enable/Disablep.224MSI Check Character Calculationp.224MSI Check Character Transmissionp.225MSI Length Controlp.225MSI Set Length 1p.226MSI Set Length 2p.227MSI Minimum Readsp.228MSI Decoding Levelp.229Code 93p.230Code 93 Enable/Disablep.230Code 93 Check Character Calculationp.230Code 93 Check Character Transmissionp.231Code 93 Length Controlp.231Code 93 Set Length 1p.232Code 93 Set Length 2p.233Code 93 Minimum Readsp.234Code 93 Decoding Levelp.235Code 93 Quiet Zonesp.236Code 93 Stitchingp.237Code 93 Character Correlationp.237Codablock Fp.238Codablock F Enable/Disablep.238Codablock F EAN Enable/Disablep.238Codablock F AIM Checkp.239Codablock F Length Controlp.239Codablock F Set Length 1p.240Codablock F Set Length 2p.241Code 4p.242Code 4 Enable/Disablep.242Code 4 Check Character Transmissionp.242Code 4 Hex to Decimal Conversionp.243Code 5p.243Code 5 Enable/Disablep.243Code 5 Check Character Transmissionp.244Code 5 Hex to Decimal Conversionp.244Code 4 and Code 5 Common Configuration Itemsp.245Code 4 and 5 Decoding Levelp.245Code 4 and Code 5 Minimum Readsp.246Follett 2 of 5p.247Follett 2 of 5 Enable/Disablep.247BC412p.247BC412 Enable/Disablep.247BC412 Check Character Calculationp.248BC412 Minimum Readsp.248BC412 Decoding Levelp.249BC412 Length Controlp.250BC412 Set Length 1p.250BC412 Set Length 2p.251Plesseyp.252Plessey Enable/Disablep.252Plessey Check Character Calculationp.253Plessey Check Character Transmissionp.254Plessey Length Controlp.254Plessey Set Length 1p.255Plessey Set Length 2p.256Plessey Minimum Readsp.257Plessey Decoding Levelp.258Plessey Stitchingp.259Plessey Character Correlationp.259Referencesp.261RS-232 Parametersp.262RS-232 Onlyp.262RS-232/USB COM Parametersp.263Keyboard Interfacep.270Wedge Quiet Intervalp.270Intercharacter Delayp.271Intercode Delayp.272Data Formatp.273Data Editingp.273Global Prefix/Suffixp.274Global AIM IDp.275Label IDp.276Set Global Mid Label ID Character(s)p.280Character Conversionp.280Reading Parametersp.282Label Gone Timeoutp.282Good Read LED Durationp.283Scanning Featuresp.284Scan Modep.284Scanning Active Timep.285Flash On Timep.286Flash Off Timep.287Symbologiesp.288Decoding Levelsp.288Set Lengthp.288Technical Specificationsp.291Standard Cable Pinoutsp.293LED and Beeper Indicationsp.294Error Codesp.295Standard Defaultsp.297Default Exceptionsp.308Sample Bar Codesp.3111D Bar Codesp.311GS1 DataBar (RSS)p.313GS1 DataBar-14p.313Keypadp.315Scancode Tablesp.319Control Character Emulationp.319Interface Type PC AT PS/2 or USB-Keyboardp.320Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Modep.322Digital Interfacep.324IBM XTp.326Microsoft Windows Codepage 1252p.328ASCII Chartp.331
Page 10 of the Solis 842 user manual — NOTES
Page 10 · click to enlarge
Page 10

NOTES

Contents · viii Touch TD1100

Page 11 of the Solis 842 user manual — Overview
Page 11 · click to enlarge
Page 11

Chapter 1

Introduction

About the Touch TD1100

The Touch™ TD1100 series of linear imaging contact readers represent the Datalogic ADC solution for customers who require a cost-effective solution for close contact bar code reading without sacrificing quality and performance.

Designed for low throughput applications within multiple markets, the Touch TD1100 readers provide the guarantee of contact reading with an excellent reading performance on virtually all linear bar codes, including damaged or poorly printed codes.

Small, lightweight and low on energy consumption, the Touch TD1100 readers can still provide robustness and a 1.5 m / 5.0 ft drop resistance, which is typically included in a higher range of products.

The Touch readers are available with the option of two different sizes of reading windows: 6.5 cm / 2.6 in (Touch 65) or 9.0 cm / 3.5 in (Touch 90), which benefits the user when reading either standard or wide bar codes.

The Touch 65/90 Pro readers provide a complete all-in-one multi-interface solution, including RS-232, USB, and Keyboard Wedge Emulation, while the Touch Lite 65/90 readers provide USB-only or RS-232 / Keyboard Wedge interfaces.

About this Manual

This Product Reference Guide (PRG) is provided for users seeking advanced technical information, including connection, programming, maintenance and specifications. The Quick Reference Guide (QRG) and other publications associated with this product are downloadable free of charge from the website listed on the back cover of this manual.

Typically, units are factory-programmed for the most common terminal and communications settings. If you need to modify any programmable settings, custom configuration can be accomplished by scanning the programming bar codes within this guide.

Programming can alternatively be performed using the Datalogic Aladdin™ Configuration application which is downloadable from the Datalogic website listed on the back cover of this manual. This multi-platform utility program allows device configuration using a PC. It communicates to the device using a serial or USB cable and can also create configuration bar codes to print.

Overview

Chapter 1, Introduction provides a product overview, unpacking instructions, and cable connection information.

Page 12 of the Solis 842 user manual — Reseller Technical Support
Page 12 · click to enlarge
Page 12

Chapter 2, Setup presents information about unpacking and setting up the reader, and interface configuration bar codes and details.

Chapter 3, Configuration Using Bar Codes provides instructions and bar code labels for customizing your reader. There are different sections for interface types, general features, data formatting, symbology-specific and model-specific features.

Chapter 4, References provides details concerning programmable features.

Appendix A, Technical Specifications lists physical and performance characteristics, as well as environmental and regulatory specifications. It also provides standard cable pin-outs and descriptions of the functions and behaviors of the reader’s LED and Beeper indicators.

Appendix B, Standard Defaults references common factory default settings for reader features and options.

Appendix C, Sample Bar Codes offers sample bar codes of several common symbologies.

Appendix D, Keypad includes numeric bar codes to be scanned for certain parameter settings.

Appendix E, Scancode Tables lists control character emulation information for Wedge and USB Keyboard interfaces.

Conventions

The symbols listed below are used in this manual to notify the reader of key issues or procedures that must be observed when using the reader:

NOTE

The CAUTION symbol advises you of actions that could damage equipment or property.

CAUTION

Technical Support

Datalogic Website Support

The Datalogic website (www.datalogic.com) is the complete source for technical support and information for Datalogic products. The site offers product support, warranty information, product manuals, product tech notes, software updates, demos, and instructions for returning products for repair.

Reseller Technical Support

An excellent source for technical assistance and information is an authorized Datalogic reseller. A reseller is acquainted with specific types of businesses, application software, and computer systems and can provide individualized assistance.

Introduction Technical Support

Page 13 of the Solis 842 user manual — Telephone Technical Support
Page 13 · click to enlarge
Page 13

Telephone Technical Support

If you do not have internet or email access, you may contact Datalogic technical support at (541) 349-8283 or check the back cover of your manual for more contact information.

Current versions of the Product Reference Guide (PRG), Quick Reference Guide (QRG), the Datalogic Aladdin™ Configuration application, software/firmware and any additional manuals, instruction sheets and utilities for this product can be downloaded from the website listed on the back cover of this manual. Alternatively, printed copies or product support CDs can be purchased through your Datalogic reseller.

Technical Support Introduction

Page 14 of the Solis 842 user manual — NOTES
Page 14 · click to enlarge
Page 14

NOTES

Introduction Technical Support

Page 15 of the Solis 842 user manual — Install the Interface Cable
Page 15 · click to enlarge
Page 15

Chapter 2

Setup

Unpacking

Check carefully to ensure the reader and any accessories ordered are present and undamaged. If any damage occurred during shipment, contact Technical Support on page 2.

KEEP THE PACKAGING. Should the unit ever require service, it should be returned in its original shipping container.

Setting Up the Reader

Follow the steps provided in this section to connect and get your reader up and communicating with its host:

1. Install the Interface Cable (see below).
2. " Connect Host Interface" on page 7 .
3. Modify " Customizing Configuration Settings" on page 12 (only if modifications are needed from factory settings).

Install the Interface Cable

The reader kit you ordered to match your interface should provide a compatible cable for your installation. If not, contact Technical Support.

Seat the cable assembly into the reader, aligning both the connector and the cable clip with its opening. To disconnect the cable, insert a paper clip or similar object into the opening on the reader, as shown in Figure 1 on page 6.

Page 16 of the Solis 842 user manual — Setup
Page 16 · click to enlarge
Page 16

Setup Setting Up the Reader

Figure 1. Connecting/Disconnecting the Interface Cable to the Reader

Depending on the model, the reader can communicate using the following interfaces:

RS-232: The reader can communicate with a standard or Wincor-Nixdorf (W-N) RS-232 host.

RS-232 OPOS: This interface is used for OPOS/UPOS/JavaPOS systems.

Keyboard Wedge (KBW) : When connected using this interface, the host interprets scanned data as keystrokes and supports several international keyboards (for the Windows® environment). See "Country Mode" on page 35 for a full listing.

Wand: The Touch 65/90 Pro can be set to use the Wand Emulation interface.

USB: Select to communicate either by USB OEM, USB COM STD, or USB Keyboard interface types by scanning the appropriate interface type bar codes available in this manual. The default interface is USB-KBD (Touch Lite USB and Touch Pro), or RS232-STD (Touch Lite RS232).

Page 17 of the Solis 842 user manual — Keyboard Wedge Connection
Page 17 · click to enlarge
Page 17

Setting Up the Reader Setup

Connect Host Interface

RS-232 Serial Connection

Turn off power to the terminal/PC and connect the reader to the terminal/PC serial port via the RS-232 cable as shown. If the terminal will not support POT (Power Off the Terminal) to supply reader power, use the approved power supply (AC Adapter). Plug the AC Adapter barrel connector into the socket on the RS-232 cable connector and the AC Adapter plug into a standard power outlet.

Solis 842 — RS-232 Serial Connection diagram (page 17)
Fig. 7 · RS-232 Serial Connection

Keyboard Wedge Connection

The Keyboard Wedge cable has a ‘Y’ connection from the reader. Connect the female to the male end from the keyboard and the remaining end at the keyboard port at the terminal/PC.

Solis 842 — Keyboard Wedge Connection diagram (page 17)
Fig. 8 · Keyboard Wedge Connection

RS-232 Interface · Keyboard Wedge Interface

Page 18 of the Solis 842 user manual — NOTE
Page 18 · click to enlarge
Page 18

USB Connection Connect the reader to a USB port on the terminal/PC using the correct USB cable for the interface type you ordered.

Solis 842 — Holder/Hands-Free Stand diagram (page 18)
Fig. 9 · Holder/Hands-Free Stand

Specific cables are required for connection to different hosts. The connectors illustrated above are examples only. Actual connectors may vary from those illus- trated, but the steps to connect the reader remain the same.

NOTE

Holder/Hands-Free Stand

The TD1100 Holder can also be used as a hands-free stand. Insert the reader nose-first into the holder, then pass the bar code beneath the stand. Refer to "Configuration Using Bar Codes" starting on page 15 for information about programming the reader for use with the stand.

Figure 2. Hands-Free Stand

Solis 842 — NOTE diagram (page 18)
Fig. 10

Setup Holder/Hands-Free Stand · USB Interface

Page 19 of the Solis 842 user manual — NOTE
Page 19 · click to enlarge
Page 19

Interface Selection

Upon completing the physical connection between the reader and its host, proceed directly to "Configuring the Interface" on page 9 for information and programming for the interface type the reader is connected to (for example: RS-232, Keyboard Wedge, USB, etc.) and scan the appropriate bar code in tha section to select your system’s correct interface type.

The reader, depending upon the model, will support one of the following sets of host interfaces:

USB Models (3.0 full speed)

  • USB-KBD
  • USB-COM STD
  • USB-OEM
  • USB-KBD-ALT

RS-232 / Keyboard Wedge Models

  • RS-232 (Standard, Wincor-Nixdorf, OPOS)
  • Keyboard Wedge

Wand Interface (TD1130 Pro only)

Configuring the Interface

Scan the programming bar code from the following section which selects the appropriate interface type matching the system the reader will be connected to. Next, proceed to the corresponding chapter in this manual (also listed in the table) to configure any desired settings and features associated with that interface.

Unlike some other programming features and options, interface selections require that you scan only one programming bar code label. DO NOT scan an ENTER/EXIT bar code prior to scanning an interface selection bar code.

Some interfaces require the reader to start in the disabled state when powered up. If additional reader configuration is desired while in this state, pull the trig- ger and hold it for five seconds. The reader will change to a state that allows programming with bar codes.

NOTE

Interface Selection Setup

Page 20 of the Solis 842 user manual — Interface Selection
Page 20 · click to enlarge
Page 20

Table 1. Available Interfaces

Solis 842 — Interface Selection diagram (page 20)
Fig. 11 · Interface Selection

a. Download the correct USB Com driver from www.datalogic.com

Solis 842 — Interface Selection diagram (page 20)
Fig. 12 · Interface Selection

AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key Encoding

Setup Interface Selection

Page 21 of the Solis 842 user manual — Interface Selection
Page 21 · click to enlarge
Page 21
Solis 842 — Interface Selection diagram (page 21)
Fig. 13 · Interface Selection

Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard

AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key

Interface Selection Setup

Page 22 of the Solis 842 user manual — NOTE
Page 22 · click to enlarge
Page 22

Setup Customizing Configuration Settings

Customizing Configuration Settings

Using the Programming Bar Codes

This manual contains feature descriptions and bar codes which allow you to reconfigure your reader. Some programming bar code labels, like "Resetting the Product Configuration to Defaults" on page 14, require only the scan of that single label to enact the change. Most of the programming labels in this manual, however, require the reader to be placed in Programming Mode prior to scanning them. Scan an ENTER/EXIT bar code once to enter Programming Mode. Once the reader is in Programming Mode, you can scan a number of parameter settings before scanning the ENTER/EXIT bar code a second time, which will then accept your changes, exit Programming Mode and return the reader to normal operation.

There are some exceptions to the typical programming sequence described above. Please read the description and setting instructions carefully when configuring each given programmable feature.

NOTE

Datalogic Aladdin™

Programming can alternatively be performed using the Datalogic Aladdin™ Configuration application which is available for free download from the Datalogic website listed on the back cover of this manual. This multi-platform utility program allows device configuration using a PC. It communicates to the device using a serial or USB cable and can also create configuration bar codes to print.

Datalogic Aladdin™ is a multi-platform utility program providing a quick and user-friendly configuration method via the RS-232/USB-COM interface. Aladdin is available on the CD- ROM provided with your product, and also from the Datalogic website. Aladdin allows you to program the reader by selecting configuration commands through a user-friendly graphical interface running on a PC. These commands are sent to the reader over the selected communication interface, or they can be printed as bar codes to be scanned.

Aladdin also provides the ability to perform a software upgrade for the connected device (see the Datalogic Aladdin™ Help On-Line for more details).

Page 23 of the Solis 842 user manual — Software Version Transmission
Page 23 · click to enlarge
Page 23

Customizing Configuration Settings Setup

Interface Settings

The reader is typically factory-configured with a set of default features standard to the interface type you ordered. See "Interface Selection" on page 9.

Global Interface Features, starting on page 17 provides settings configurable by all interface types. If your installation requires you to further customize your reader, you can select other options through use of the instructions and programming bar codes available in the appropriate section for your interface.

  • RS-232 Only Interface, starting on page 19
  • RS-232/USB-Com Interfaces, starting on page 25
  • Keyboard Interface, starting on page 35
  • USB-OEM Interface, starting on page 47

Configuring Other Features

If your installation requires different programming than the standard factory default settings, the following sections of this manual allow configuration of non-interface-specific settings you might require:

Configuration Using Bar Codes: General Features includes programming for scanning, beeper and LED indicators and other such universal settings.

Reading Parameters: Reading Parameters include programming for scanning, beeper and LED indicators and other universal settings.

Symbologies: Includes options concerning the bar code label types (symbologies). These settings allow you to enable/disable symbologies, set label lengths, require check digit, etc.

Software Version Transmission

The software version of the device can be transmitted over the RS-232, Keyboard and USB interfaces by scanning the following label.

RevA · Transmit Software Version

Page 24 of the Solis 842 user manual — CAUTION
Page 24 · click to enlarge
Page 24

Setup Customizing Configuration Settings

Resetting the Product Configuration to Defaults

If you aren't sure what programming options are in your reader, or you've changed some options and want to restore the Custom Default Configuration that may have been saved in the reader, scan the Restore Custom Default Configuration bar code below. This will restore the custom configuration for the currently active interface.

Custom defaults are based on the interface type. Configure the reader for the correct interface before scanning this label.

NOTE

Restore Custom Default Configuration

If you aren't sure what programming options are in your reader, or you've changed some options and want to restore the Factory Configuration, you have two options. You can scan the Restore USA Factory Configuration bar code or the Restore EU Factory Configuration bar code below. Both labels restore the reader configuration to the factory settings including the interface type. The USA label restores Label IDs to those historically used in the USA. The EU label restores Label IDs to those historically used in Europe. The Label ID sets for USA and EU are shown in the Label ID section of this manual.

Scanning either of the “Restore Factory Configuration” commands below will result in the loss of any custom configuration settings for your device.

CAUTION

Restore USA Factory Configuration

Restore EU Factory Configuration

The programming section on the following pages lists the factory default settings for each of the menu commands (indicated by shaded blocks and bold text).

Page 25 of the Solis 842 user manual — NOTE
Page 25 · click to enlarge
Page 25

Chapter 3

Configuration Using Bar Codes

This and following sections provide programming bar codes to configure your reader by changing the default settings. For details about additional methods of programming, see "Customizing Configuration Settings" on page 12.

You must first enable your reader to read bar codes in order to use this section. If you have not done this, go to Setup, starting on page 5 and complete the appropriate procedure.

NOTE

Configuration Parameters

Once the reader is set up, you can change the default parameters to meet your application needs. Refer to "Resetting the Product Configuration to Defaults" on page 14 for initial configuration in order to set the default values and select the interface for your application.

The following configuration parameters are divided into logical groups, making it easy to find the desired function based on its reference group.

Interface Configuration:

  • "RS-232 Only Interface" on page 19
  • "RS-232/USB-Com Interfaces" on page 25
  • "Keyboard Interface" on page 35
  • "USB-OEM Interface" on page 47

Parameters common to all interface applications:

  • " Global Prefix/Suffix" on page 54
  • " Data Format" on page 53 offers advanced configuration options for customization of scanned data output.
  • " Reading Parameters" on page 67 control various operating modes and indicators status functioning.

Symbology-specific parameters: "Symbologies" on page 87 defines options for all symbologies and provides the programming bar codes necessary for configuring these features.

You must first enable your reader to read bar codes in order to use this section. If you have not done this, go to Setup, starting on page 5 and complete the appropriate procedure.

NOTE

Page 26 of the Solis 842 user manual — NOTE
Page 26 · click to enlarge
Page 26

To program features:

1. Scan the ENTER/EXIT PROGRAMMING bar code, available at the top of each programming page, when applicable.
2. Scan the bar code to set the desired programming feature. You may need to cover unused bar codes on the page, and possibly the facing page, to ensure that the reader reads only the bar code you intend to scan.
3. If additional input parameters are needed, go to Appendix D, Keypad , and scan the appropriate characters from the keypad.

Additional information about many features can be found in the “Refer ences” chapter.

If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

NOTE

4. Complete the programming sequence by scanning the ENTER/EXIT PROGRAM MING bar code to exit Programming Mode.

For more detailed descriptions, programming information and examples for setting selected configuration items, see References, starting on page 251.

Enter/Exit Programming Mode

Page 27 of the Solis 842 user manual — $CIFIH01
Page 27 · click to enlarge
Page 27

GLOBAL INTERFACE FEATURES

The following interface features are configurable by all interface types. To set features specific to your interface, turn to that section of this manual:

  • " RS-232 Only Interface" on page 19
  • " RS-232/USB-Com Interfaces" on page 25
  • " Keyboard Interface" on page 35
  • " USB-OEM Interface" on page 47

Host Commands — Obey/Ignore

This option specifies whether the reader will obey or ignore host commands. When set to ignore, the reader will ignore all host commands except for those necessary for:

  • service mode
  • flash programming mode
  • keeping the interface active
  • transmission of labels.

$CIFIH00

Host Commands = Obey

$CIFIH01

Host Commands = Ignore

Enter/Exit Programming Mode

Page 28 of the Solis 842 user manual — $CUSSE01
Page 28 · click to enlarge
Page 28

USB Suspend Mode

The reader always goes to USB suspend mode (low power consumption) when the connected PC goes to standby mode. This setting enables/disables the ability of USB interfaces to wake up the PC by a trigger pull.

When disabled, a scanner with a USB keyboard interface active will not wake up the PC by trigger pull.

$CUSSE00

USB Suspend Mode = Disable

$CUSSE01

USB Suspend Mode = Enable

Enter/Exit Programming Mode

Page 29 of the Solis 842 user manual — Baud Rate
Page 29 · click to enlarge
Page 29
Solis 842 — RS-232 Only Interface diagram (page 29)
Fig. 14 · RS-232 Only Interface

RS-232 ONLY INTERFACE

Use the programming bar codes in this chapter if modifications to the standard RS-232 interface settings are necessary to meet your system’s requirements. Additional settings which apply to both the RS-232 and USB interfaces are available in Chapter 3, RS-232/USB-Com Interfaces.

RS-232 Standard Factory Settings

Reference Appendix B, Standard Defaults for a listing of standard factory settings.

Baud Rate

Baud rate is the number of bits of data transmitted per second. Set the reader's baud rate to match the baud rate setting of the host device. With an improper baud rate setting, data may not reach the host correctly.

Solis 842 — Baud Rate diagram (page 29)
Fig. 15 · Baud Rate
Page 30 of the Solis 842 user manual — Baud Rate — continued
Page 30 · click to enlarge
Page 30

Enter/Exit Programming Mode Baud Rate

Baud Rate — continued

Solis 842 — Baud Rate — continued diagram (page 30)
Fig. 16 · Baud Rate — continued
Page 31 of the Solis 842 user manual — Stop Bits
Page 31 · click to enlarge
Page 31
Solis 842 — Data Bits diagram (page 31)
Fig. 17 · Data Bits

Data Bits

This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCII protocol for sending and receiving data.

The scanner cannot support 7-bit-data when parity-none is set.

NOTE

Solis 842 — NOTE diagram (page 31)
Fig. 18

Stop Bits

The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits selected (one or two) depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.

Solis 842 — Stop Bits diagram (page 31)
Fig. 19 · Stop Bits
Page 32 of the Solis 842 user manual — Parity
Page 32 · click to enlarge
Page 32

Enter/Exit Programming Mode Parity

Parity

This feature specifies parity required for sending and receiving data. A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements.

  • Select None when no parity bit is required.
  • Select Odd parity and the parity bit value is set to 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character.
  • Select Even parity and the parity bit value is set to 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character.
Solis 842 — Parity diagram (page 32)
Fig. 20 · Parity
Page 33 of the Solis 842 user manual — Handshaking Control
Page 33 · click to enlarge
Page 33
Solis 842 — Handshaking Control diagram (page 33)
Fig. 21 · Handshaking Control

Handshaking Control

The data interface consists of an RS-232 port designed to operate either with or without the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). Handshaking Control includes the following options:

  • RTS — RTS is asserted during transmissions. CTS is ignored.
  • RTS/CTS — RTS is asserted during transmissions. CTS gates transmissions.
  • RTS/XON/XOFF — RTS is asserted during transmissions. CTS is ignored. XON and XOFF gate transmissions.
  • RTS On/CTS — RTS is always asserted. CTS gates transmissions.
  • RTS/CTS Scan Control — RTS is asserted during transmissions. CTS gates transmis sions and controls enable and disable state of reader.
Solis 842 — Handshaking Control diagram (page 33)
Fig. 22 · Handshaking Control
Page 34 of the Solis 842 user manual — NOTES
Page 34 · click to enlarge
Page 34

NOTES

Page 35 of the Solis 842 user manual — Intercharacter Delay
Page 35 · click to enlarge
Page 35
Solis 842 — RS-232/USB-Com Interfaces diagram (page 35)
Fig. 23 · RS-232/USB-Com Interfaces

RS-232/USB-COM INTERFACES

The programming bar codes in this chapter allow modifications to the standard RS-232 and USB-Com interfaces.

Standard Factory Settings

Reference Appendix B, Standard Defaults for a listing of standard factory settings.

Intercharacter Delay

This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. See "Label ID: Pre-loaded Sets" on page 266 for more detailed programming instructions.

Solis 842 — Intercharacter Delay diagram (page 35)
Fig. 24 · Intercharacter Delay

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Make a mistake? Scan the CANCEL bar code to abort and not

save the entry string. You can then start again at the begin-

Page 36 of the Solis 842 user manual — Beep On Not on File
Page 36 · click to enlarge
Page 36

Enter/Exit Programming Mode Beep On ASCII BEL

Beep On ASCII BEL

When this parameter is enabled, the reader issues a beep when a character is detected on the RS-232 serial line. is issued to gain a user's attention to an illegal entry or other important event.

Solis 842 — Beep On ASCII BEL diagram (page 36)
Fig. 25 · Beep On ASCII BEL

Beep On Not on File

This option enables/disables the action of the reader to sound a three beep sequence upon receiving a Not-On-File (NOF) host command.

Solis 842 — Beep On Not on File diagram (page 36)
Fig. 26 · Beep On Not on File
Page 37 of the Solis 842 user manual — ACK NAK Options
Page 37 · click to enlarge
Page 37
Solis 842 — ACK NAK Options diagram (page 37)
Fig. 27 · ACK NAK Options

ACK NAK Options

This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. When configured, the reader and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error.

Options are:

  • Disable
  • Enable for label transmission — The reader expects an ACK/NAK response from the host when a label is sent.
  • Enable for host-command acknowledge — The reader will respond with ACK/NAK when the host sends a command.
  • Enable for label transmission and host-command acknowledge
Solis 842 — ACK NAK Options diagram (page 37)
Fig. 28 · ACK NAK Options

ACK/NAK Protocol = Enable for label transmission and host-

Page 38 of the Solis 842 user manual — DEFAULT 0x15 ‘NAK’ Character
Page 38 · click to enlarge
Page 38

Enter/Exit Programming Mode ACK NAK Options

ACK Character

This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected. See "ACK Character" on page 254 for more detailed programming instructions.

Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8- bit data is not recognized when the option Data Bits has been set as 7 Data Bits.

NOTE

$CR2AC

Select ACK Character Setting

DEFAULT 0x06 ‘ACK’ Character

NAK Character

This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected. See "NAK Character" on page 255 for more detailed programming instructions.

Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8- bit data is not recognized when the option Data Bits has been set as 7 Data Bits.

NOTE

$CR2NA

Select NAK Character Setting

DEFAULT 0x15 ‘NAK’ Character

Page 39 of the Solis 842 user manual — CANCEL
Page 39 · click to enlarge
Page 39

ACK NAK Options Enter/Exit Programming Mode

ACK NAK Timeout Value

This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout. See "ACK NAK Timeout Value" on page 256 for more detailed programming instructions.

$CR2AT

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select ACK NAK Timeout Value Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 01 ACK NAK Timeout value is 200ms

~

Page 40 of the Solis 842 user manual — CANCEL
Page 40 · click to enlarge
Page 40

Enter/Exit Programming Mode ACK NAK Options

ACK NAK Retry Count

This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries. See "ACK NAK Retry Count" on page 257 for more detailed programming instructions.

$CR2AR

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select ACK NAK Retry Count Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 003 = 3 Retries

~

Page 41 of the Solis 842 user manual — ACK NAK Error Handling
Page 41 · click to enlarge
Page 41
Solis 842 — ACK NAK Error Handling diagram (page 41)
Fig. 29 · ACK NAK Error Handling

ACK NAK Error Handling

This feature specifies the method the reader uses to handle receive errors detected while waiting for an ACK character from the host.

Options are:

  • Ignore errors detected
  • Process error as valid ACK character
  • Process error as valid NAK character
Solis 842 — ACK NAK Error Handling diagram (page 41)
Fig. 30 · ACK NAK Error Handling

ACK NAK Error Handling = Process Error as Valid ACK Character

Page 42 of the Solis 842 user manual — NOTE
Page 42 · click to enlarge
Page 42

Enter/Exit Programming Mode Indicate Transmission Failure

Indicate Transmission Failure

This option enables/disables the reader’s ability to sound an error beep to indicate a transmission failure while in ACK/NAK mode.

Solis 842 — Indicate Transmission Failure diagram (page 42)
Fig. 31 · Indicate Transmission Failure

Disable Character

Specifies the value of the RS-232 host command used to disable the reader.

ASCII characters or any hex value from 0 to 0xFF can be selected. See "Disable Character" on page 258 for more detailed programming instructions.

Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8- bit data is not recognized when the option Data Bits has been set as 7 Data Bits.

NOTE

Solis 842 — NOTE diagram (page 42)
Fig. 32
Page 43 of the Solis 842 user manual — DEFAULT 0x45 = Enable Character is ‘E’
Page 43 · click to enlarge
Page 43

Enable Character Enter/Exit Programming Mode

Enable Character

Specifies the value of the RS-232 host command used to enable the reader.

ASCII characters or any hex value from 0 to 0xFF can be selected. See "Enable Character" on page 259 for more detailed programming instructions.

Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8- bit data is not recognized when the option Data Bits has been set as 7 Data Bits.

NOTE

$CR2EC

Select Enable Character Setting

DEFAULT 0x45 = Enable Character is ‘E’

Page 44 of the Solis 842 user manual — NOTES
Page 44 · click to enlarge
Page 44

Enter/Exit Programming Mode Enable Character

NOTES

Page 45 of the Solis 842 user manual — Country Mode
Page 45 · click to enlarge
Page 45
Solis 842 — Keyboard Interface diagram (page 45)
Fig. 33 · Keyboard Interface

KEYBOARD INTERFACE

Use the programming bar codes in this chapter to select options for USB Keyboard and Wedge Interfaces. Reference Appendix B, Standard Defaults for a listing of standard factory settings. Information about control character emulation which applies to keyboard interfaces is listed in Appendix E, Scancode Tables.

Country Mode

This feature specifies the country/language supported by the keyboard.

Only the following interfaces support ALL Country Modes.

  • USB Keyboard (without alternate key encoding)
  • Keyboard Wedge

All other interfaces support ONLY the following Country Modes: U.S., Belgium, Britain, France, Germany, Italy, Spain, Sweden.

Solis 842 — Country Mode diagram (page 45)
Fig. 34 · Country Mode

Supports only the interfaces listed in the Country Mode feature description.

Supports only the interfaces listed in the Country Mode fea- ture description.

Page 46 of the Solis 842 user manual — Country Mode — continued
Page 46 · click to enlarge
Page 46

Enter/Exit Programming Mode Country Mode

Country Mode — continued

Solis 842 — Country Mode — continued diagram (page 46)
Fig. 35 · Country Mode — continued

Supports only the interfaces listed in the Country Mode feature description.

Supports only the interfaces listed in the Country Mode fea ture description.

Supports only the interfaces listed in the Country Mode fea ture description.

Supports only the interfaces listed in the Country Mode

Page 47 of the Solis 842 user manual — Country Mode — continued
Page 47 · click to enlarge
Page 47
Solis 842 — Keyboard Interface diagram (page 47)
Fig. 36 · Keyboard Interface

Country Mode — continued

Solis 842 — Country Mode — continued diagram (page 47)
Fig. 37 · Country Mode — continued

Supports only the interfaces listed in the Country Mode feature description.

Supports only the interfaces listed in the Country Mode fea ture description.

Supports only the interfaces listed in the Country Mode feature description.

Supports only the interfaces listed in the Country Mode fea ture description.

Supports only the interfaces listed in the Country Mode feature description.

Page 48 of the Solis 842 user manual — Numlock
Page 48 · click to enlarge
Page 48

Enter/Exit Programming Mode Caps Lock State

Caps Lock State

This option specifies the format in which the reader sends character data. This applies to Keyboard Wedge interfaces. This does not apply when an alternate key encoding keyboard is selected.

Solis 842 — Caps Lock State diagram (page 48)
Fig. 38 · Caps Lock State

Numlock

This option specifies the setting of the Numbers Lock (Numlock) key while in Keyboard Wedge interface. This only applies to alternate key encoding interfaces. It does not apply to USB Keyboard.

Solis 842 — Numlock diagram (page 48)
Fig. 39 · Numlock
Page 49 of the Solis 842 user manual — $CKBKP01
Page 49 · click to enlarge
Page 49

Keyboard Numeric Keypad Enter/Exit Programming Mode

Keyboard Numeric Keypad

This feature specifies if numeric characters will be sent using the standard keys or the numeric keypad.

$CKBKP00

Keyboard Numeric Keypad = Standard Keys

$CKBKP01

Keyboard Numeric Keypad = Numeric Keypad

Page 50 of the Solis 842 user manual — Keyboard Send Control Characters
Page 50 · click to enlarge
Page 50

Enter/Exit Programming Mode Keyboard Send Control Characters

Keyboard Send Control Characters

This feature is used by the Keyboard Wedge and USB Keyboard interfaces. It specifies how the reader transmits ASCII control characters to the host. Reference Appendix E, Scancode Tables for more information about control characters.

Options are as follows:

Send Ctrl+Key : ASCII characters from 00H to 0x1FH inclusive are transmitted in the format Ctrl+Key. Special keys are available in the range from 81H to A1.

Send Ctrl+Shift+Key : The behavior is the same as above, but control keys are sent in the format Ctrl+Shift+Keys.

Send Special Function Key : Send characters between 00H and 1FH according to the special function key mapping table (see "Microsoft Windows Codepage 1252" on page 318). This is used to send keys that are not in the normal ASCII set. A unique set is provided for each available scancode set.

Solis 842 — Keyboard Send Control Characters diagram (page 50)
Fig. 40 · Keyboard Send Control Characters
Page 51 of the Solis 842 user manual — CANCEL
Page 51 · click to enlarge
Page 51

Wedge Quiet Interval Enter/Exit Programming Mode

Wedge Quiet Interval

This option specifies the amount of time to look for keyboard activity before the reader breaks the keyboard connection in order to transmit data to host. The selectable range for this feature is from 0 to 990ms in 10ms increments. See "Wedge Quiet Interval" on page 260 for more detailed programming instructions.

This feature applies ONLY to the Keyboard Wedge interface.

NOTE

$CKBQI

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad representing your desired character(s). End by scanning the ENTER/EXIT bar code again.

Select Wedge Quiet Interval Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

CANCEL

DEFAULT 10 = Quiet Interval of 100 ms

~

Page 52 of the Solis 842 user manual — NOTE
Page 52 · click to enlarge
Page 52

Enter/Exit Programming Mode Intercharacter Delay

Intercharacter Delay

This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. See "Intercharacter Delay" on page 261 for more detailed programming instructions.

This feature applies ONLY to the Keyboard Wedge interface.

NOTE

Solis 842 — NOTE diagram (page 52)
Fig. 41

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad representing your desired character(s). End by scanning the ENTER/EXIT bar code again.

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at

Page 53 of the Solis 842 user manual — CANCEL
Page 53 · click to enlarge
Page 53

Intercode Delay Enter/Exit Programming Mode

Intercode Delay

Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds. See "Intercode Delay" on page 262 for more detailed programming instructions.

$CKBID

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad representing your desired character(s). End by scanning the ENTER/EXIT bar code again.

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

CANCEL

DEFAULT 00 = No Wedge Intercode Delay

Set Intercode Delay · ~

Page 54 of the Solis 842 user manual — NOTE
Page 54 · click to enlarge
Page 54

Enter/Exit Programming Mode USB Keyboard Speed

USB Keyboard Speed

This option specifies the USB poll rate for a USB Keyboard.

This feature applies ONLY to the USB Keyboard interface.

NOTE

Solis 842 — NOTE diagram (page 54)
Fig. 42
Page 55 of the Solis 842 user manual — USB Keyboard Speed — continued
Page 55 · click to enlarge
Page 55
Solis 842 — USB Keyboard Speed diagram (page 55)
Fig. 43 · USB Keyboard Speed

USB Keyboard Speed — continued

Solis 842 — USB Keyboard Speed — continued diagram (page 55)
Fig. 44 · USB Keyboard Speed — continued
Page 56 of the Solis 842 user manual — NOTES
Page 56 · click to enlarge
Page 56

Enter/Exit Programming Mode USB Keyboard Speed

NOTES

Page 57 of the Solis 842 user manual — Standard Factory Settings
Page 57 · click to enlarge
Page 57

USB-OEM INTERFACE

Introduction

Feature settings for USB interfaces differ depending upon which host type the reader will be connected with. Use the feature settings in this chapter to specifically configure for the USB- OEM interface. Other USB interfaces are included in the appropriate chapter for their host type.

Standard Factory Settings

Reference Appendix B, Standard Defaults for a listing of standard factory settings.

Page 58 of the Solis 842 user manual — USB-OEM Interface Options
Page 58 · click to enlarge
Page 58

Enter/Exit Programming Mode USB-OEM Device Usage

USB-OEM Device Usage

The USB-OEM protocol allows for the reader to be identified as one of two different types of bar code readers. Depending on what other scanners you may already have connected to a USB- OEM POS, you may need to change this setting to enable all devices to communicate.

Options are:

  • Table Top Scanner
  • Handheld Scanner

It may be necessary to switch device usage when connecting two readers/scanners of the same type to a POS system.

NOTE

Solis 842 — NOTE diagram (page 58)
Fig. 45

USB-OEM Interface Options

This setting provides for an interface specific control mechanism.

Options are:

  • Obey — Obey Reader Configuration Host Commands
  • Ignore — Ignore Reader Configuration Host Commands
Solis 842 — USB-OEM Interface Options diagram (page 58)
Fig. 46 · USB-OEM Interface Options
Page 59 of the Solis 842 user manual — Wand Signal Speed
Page 59 · click to enlarge
Page 59
Solis 842 — Wand Emulation Interface diagram (page 59)
Fig. 47 · Wand Emulation Interface

WAND EMULATION INTERFACE

Solis 842 — WAND EMULATION INTERFACE diagram (page 59)
Fig. 48

W AND S IGNAL S PEED on page 49

W AND I DLE S TATE on page 50

L ABEL S YMBOLOGY C ONVERSION on page 52

This chapter provides feature/settings configuration for the Wand Emulation interface.

Reference Appendix B, Standard Defaults for a listing of standard factory settings.

Wand Signal Speed

This feature specifies the speed of the Wand output signal per nominal bar or space. Choices are:

  • 330 microseconds
  • 660 microseconds
Solis 842 — Wand Signal Speed diagram (page 59)
Fig. 49 · Wand Signal Speed
Page 60 of the Solis 842 user manual — NOTE
Page 60 · click to enlarge
Page 60

Wand Polarity

This option specifies the polarity of the Wand output signal. Choices are:

  • Quiet zones and spaces are high, bars are low
  • Quiet zones and spaces are low, bars are high
TTL logic levels0V <= Low <= 0.7V 2.4V <= High <= 5.25V

NOTE

Solis 842 — NOTE diagram (page 60)
Fig. 50

Wand Polarity = Quiet Zones & Spaces High, Bars Low

Wand Polarity = Quiet Zones & Spaces Low, Bars High

Wand Idle State

This feature specifies the level of the Wand output signal when the reader is idle.

TTL logic levels0V <= Low <= 0.7V 2.4V <= High <= 5.25V

NOTE

Solis 842 — NOTE diagram (page 60)
Fig. 51

Enter/Exit Programming Mode

Page 61 of the Solis 842 user manual — Transmit Noise
Page 61 · click to enlarge
Page 61
Solis 842 — Transmit Noise diagram (page 61)
Fig. 52 · Transmit Noise

Transmit Noise

This option specifies the leading/trailing noise for the Wand interface.

Solis 842 — Transmit Noise diagram (page 61)
Fig. 53 · Transmit Noise
Page 62 of the Solis 842 user manual — Label Symbology Conversion
Page 62 · click to enlarge
Page 62

Label Symbology Conversion

When this feature is enabled for the Wand Emulation interface, all barcode labels are converted to a single symbology. Options are:

  • No conversion
  • Convert to Code 39 symbology
  • Convert to Code 39 Full ASCII
  • Convert to Code 128 symbology
Solis 842 — Label Symbology Conversion diagram (page 62)
Fig. 54 · Label Symbology Conversion

Enter/Exit Programming Mode

Page 63 of the Solis 842 user manual — C ASE C ONVERSION on page 65
Page 63 · click to enlarge
Page 63

DATA FORMAT

G LOBAL P REFIX /S UFFIX on page 54

G LOBAL AIM ID on page 55

L ABEL ID starting on page 56

  • Label ID: Pre-loaded Sets
  • Label ID: Set Individually Per Symbology
  • Label ID Control
  • Label ID Symbology Selection S ET G LOBAL M ID L ABEL ID C HARACTER ( S ) on page 64

C ASE C ONVERSION on page 65

C HARACTER C ONVERSION on page 66

The features in this chapter can be used to build specific user-defined data into a message string. See "References" starting on page 251 for more detailed instructions on setting these features.

Page 64 of the Solis 842 user manual — CANCEL
Page 64 · click to enlarge
Page 64

Enter/Exit Programming Mode Global Prefix/Suffix

Global Prefix/Suffix

Up to 20 ASCII characters may be added as a prefix (in a position before the bar code data) and/ or as a suffix (in a position following the bar code data). See "Global Prefix/Suffix" on page 264 for more detailed programming instructions.

$CLFPR

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/EXIT bar code again.

$CLFSU

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad representing your desired character(s). End by scanning the ENTER/EXIT bar code again.

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT No Global Prefix Global Suffix = 0x0D(CR)

Set Global Prefix · Set Global Suffix · ~

Page 65 of the Solis 842 user manual — GS1-128 AIM ID
Page 65 · click to enlarge
Page 65
Solis 842 — Global AIM ID diagram (page 65)
Fig. 55 · Global AIM ID

Global AIM ID

This feature enables/disables addition of AIM IDs for all symbology types.

NOTE

AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data. See "Global AIM ID" on page 265 for more detailed programming instructions.

Solis 842 — NOTE diagram (page 65)
Fig. 56

GS1-128 AIM ID

If Global AIM ID is disabled, the AIM ID for GS1-128 can be enabled/disabled independently. The AIM ID for GS1-128 is a ]C1, ]C2 or ]C3.

AIM IDs for other symbologies can be enabled/disabled independently as well. Contact Customer Support for assistance.

Solis 842 — GS1-128 AIM ID diagram (page 65)
Fig. 57
Page 66 of the Solis 842 user manual — CAUTION
Page 66 · click to enlarge
Page 66

Enter/Exit Programming Mode Label ID

Label ID

A Label ID is a customizable code of up to three ASCII characters (each can be one of hex 0x01- 0xFF), used to identify a bar code (symbology) type. It can be appended previous to or following the transmitted bar code data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs as a pre-loaded set (see "Label ID: Pre-loaded Sets" on page 56) or individually per symbology (see "Label ID: Set Individually Per Symbology" on page 57). If you wish to program the reader to always include an industry standard label identifier for ALL symbology types, see the previous feature "Global AIM ID" on page 55.

Label ID: Pre-loaded Sets

The reader supports two pre-loaded sets of Label IDs. shows the USA set and the EU set. See "Label ID: Pre-loaded Sets" on page 266 for more information concerning the pre-loaded sets that are provided.

When changing from one Label ID set to another, all other reader configu- ration settings, including the host interface type, will be erased and set to the factory defaults. Any custom configuration or custom defaults will be lost.

CAUTION

$AE

Label ID Pre-loaded Set = USA Set

Label ID Pre-loaded Set = EU Set

$Ae

Page 67 of the Solis 842 user manual — NOTE
Page 67 · click to enlarge
Page 67
Solis 842 — Label ID: Set Individually Per Symbology diagram (page 67)
Fig. 58 · Label ID: Set Individually Per Symbology

Label ID: Set Individually Per Symbology

This feature configures a Label ID individually for a single symbology.

This setting requires the scanning of bar codes from multiple sec- tions. See "Label ID: Set Individually Per Symbology" on page 268 for more detailed programming instructions.

NOTE

Label ID Control

This option controls whether a Label ID is disabled, or sent as a prefix or suffix for a given symbology type.

Solis 842 — NOTE diagram (page 67)
Fig. 59

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

Page 68 of the Solis 842 user manual — Label ID Symbology Selection
Page 68 · click to enlarge
Page 68

Enter/Exit Programming Mode Label ID

Label ID Symbology Selection

This option selects the symbology for which a Label ID is to be configured. See "Label ID: Set Individually Per Symbology" on page 268 for full instructions.

Solis 842 — Label ID Symbology Selection diagram (page 68)
Fig. 60 · Label ID Symbology Selection
Page 69 of the Solis 842 user manual — Label ID Symbology Selection — continued
Page 69 · click to enlarge
Page 69
Solis 842 — Label ID Symbology Selection diagram (page 69)
Fig. 61 · Label ID Symbology Selection

Label ID Symbology Selection — continued

Solis 842 — Label ID Symbology Selection — continued diagram (page 69)
Fig. 62 · Label ID Symbology Selection — continued
Page 70 of the Solis 842 user manual — Label ID Symbology Selection — continued
Page 70 · click to enlarge
Page 70

Enter/Exit Programming Mode Label ID

Label ID Symbology Selection — continued

Solis 842 — Label ID Symbology Selection — continued diagram (page 70)
Fig. 63 · Label ID Symbology Selection — continued
Page 71 of the Solis 842 user manual — Label ID Symbology Selection — continued
Page 71 · click to enlarge
Page 71
Solis 842 — Label ID Symbology Selection diagram (page 71)
Fig. 64 · Label ID Symbology Selection

Label ID Symbology Selection — continued

Solis 842 — Label ID Symbology Selection — continued diagram (page 71)
Fig. 65 · Label ID Symbology Selection — continued

Set Interleaved 2 of 5 CIP HR Label ID Character(s)

Set Datalogic 2 of 5 CIP HR Label ID Character(s)

Page 72 of the Solis 842 user manual — Label ID Symbology Selection — continued
Page 72 · click to enlarge
Page 72

Enter/Exit Programming Mode Label ID

Label ID Symbology Selection — continued

Solis 842 — Label ID Symbology Selection — continued diagram (page 72)
Fig. 66 · Label ID Symbology Selection — continued
Page 73 of the Solis 842 user manual — Label ID Symbology Selection — continued
Page 73 · click to enlarge
Page 73
Solis 842 — Label ID Symbology Selection diagram (page 73)
Fig. 67 · Label ID Symbology Selection

Label ID Symbology Selection — continued

Solis 842 — Label ID Symbology Selection — continued diagram (page 73)
Fig. 68 · Label ID Symbology Selection — continued
Page 74 of the Solis 842 user manual — CANCEL
Page 74 · click to enlarge
Page 74

Enter/Exit Programming Mode Set Global Mid Label ID Character(s)

Set Global Mid Label ID Character(s)

Specifies a mid-label ID that is added for transmission between the labels of a two label pair. The expected string is a maximum of 20 characters. When combining two label pairs into a single label for transmission to the host, this label ID can be added to the data, following the first label and preceding the second label. See "Set Global Mid Label ID Character(s)" on page 270 for more detailed programming instructions.

$CN2MI

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad representing your desired character(s). End by scanning the ENTER/EXIT bar code again.

Set Global Mid Label ID Character(s)

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

No Global Mid Label ID

~ · Character(s) 00000000000000000000 00000000000000000000

Page 75 of the Solis 842 user manual — NOTE
Page 75 · click to enlarge
Page 75
Solis 842 — Case Conversion diagram (page 75)
Fig. 69 · Case Conversion

Case Conversion

This feature allows conversion of the case of all alphabetic characters to upper or lower case.

Case conversion affects ONLY scanned bar code data, and does not affect Label ID, Prefix, Suffix, or other appended data.

NOTE

Solis 842 — NOTE diagram (page 75)
Fig. 70
Page 76 of the Solis 842 user manual — $CLFCH
Page 76 · click to enlarge
Page 76

Enter/Exit Programming Mode Character Conversion

Character Conversion

Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done. See "Character Conversion" on page 270 for more detailed programming instructions.

$CLFCH

DEFAULT 0xFFFFFFFFFFFFFFFF(N o character conversion)

Configure Character Conversion

Page 77 of the Solis 842 user manual — Table of contents
Page 77 · click to enlarge
Page 77

Table of contents

Introductionp.11About the Touch TD1100p.11About this Manualp.11Overviewp.11Conventionsp.12Technical Supportp.12Datalogic Website Supportp.12Reseller Technical Supportp.12Telephone Technical Supportp.13Setupp.15Unpackingp.15Setting Up the Readerp.15Install the Interface Cablep.15Connect Host Interfacep.17Holder/Hands-Free Standp.18Interface Selectionp.19Configuring the Interfacep.19Customizing Configuration Settingsp.22Using the Programming Bar Codesp.22Interface Settingsp.23Configuring Other Featuresp.23Software Version Transmissionp.23Configuration Using Bar Codesp.25Configuration Parametersp.25Host Commands — Obey/Ignorep.27USB Suspend Modep.28RS-232 Only Interfacep.29RS-232 Standard Factory Settingsp.29Baud Ratep.29Data Bitsp.31Stop Bitsp.31Parityp.32Handshaking Controlp.33RS-232/USB-Com Interfacesp.35Standard Factory Settingsp.35Intercharacter Delayp.35Beep On ASCII BELp.36Beep On Not on Filep.36ACK NAK Optionsp.37ACK Characterp.38NAK Characterp.38ACK NAK Timeout Valuep.39ACK NAK Retry Countp.40ACK NAK Error Handlingp.41Indicate Transmission Failurep.42Disable Characterp.42Enable Characterp.43Keyboard Interfacep.45Country Modep.45Caps Lock Statep.48Numlockp.48Keyboard Numeric Keypadp.49Keyboard Send Control Charactersp.50Wedge Quiet Intervalp.51Intercharacter Delayp.52Intercode Delayp.53USB Keyboard Speedp.54USB-OEM Interfacep.57Introductionp.57Standard Factory Settingsp.57USB-OEM Device Usagep.58USB-OEM Interface Optionsp.58Wand Emulation Interfacep.59Wand Signal Speedp.59Wand Polarityp.60Wand Idle Statep.60Transmit Noisep.61Label Symbology Conversionp.62Data Formatp.63Global Prefix/Suffixp.64Global AIM IDp.65GS1-128 AIM IDp.65Label IDp.66Label ID: Pre-loaded Setsp.66Label ID: Set Individually Per Symbologyp.67Label ID Controlp.67Label ID Symbology Selectionp.68Set Global Mid Label ID Character(s)p.74Case Conversionp.75Character Conversionp.76Reading Parametersp.77Double Read Timeoutp.78Label Gone Timeoutp.80Power Save Modep.81Sleep Mode Timeoutp.82LED and Beeper Indicatorsp.83Power On Alertp.83Good Read: When to Indicatep.84Good Read Beep Typep.85Good Read Beep Frequencyp.85Good Read Beep Volumep.86Good Read Beep Lengthp.87Illumination Controlp.88Good Read LED Durationp.89Scanning Featuresp.90Scan Modep.90Stand Mode Triggered Timeoutp.91Scanning Active Timep.93Stand Mode Flashp.93Flash On Timep.94Flash Off Timep.94Stand Mode Sensitivityp.95Symbologiesp.97Introductionp.97Standard Factory Settings for Symbologiesp.97Disable All Symbologiesp.98Coupon Controlp.98UPC-Ap.99UPC-A Enable/Disablep.99UPC-A Check Character Transmissionp.99Expand UPC-A to EAN-13p.100UPC-A Number System Character Transmissionp.100In-Store Minimum Readsp.101UPC-Ep.102UPC-E Enable/Disablep.102UPC-E Check Character Transmissionp.102Expand UPC-E to EAN-13p.103Expand UPC-E to UPC-Ap.103UPC-E Number System Character Transmissionp.104UPC-E Minimum Readp.104EAN 13p.105EAN 13 Enable/Disablep.105EAN 13 Check Character Transmissionp.105EAN-13 Flag 1 Characterp.106EAN-13 ISBN Conversionp.106ISSN Enable/Disablep.107EAN 13 Minimum Readsp.107EAN 8p.108EAN 8 Enable/Disablep.108EAN 8 Check Character Transmissionp.108Expand EAN 8 to EAN 13p.109EAN 8 Both Guards Substitutionp.109EAN 8 Guard Insertionp.110EAN 8 Guard Substitutionp.110EAN 8 Minimum Segment Length Blockp.111EAN 8 Minimum Readsp.113EAN 8 Stitch Exact Label Halvesp.114EAN 8 Stitch Unlike Label Halvesp.114EAN Two Labelp.115EAN Two Label Enable/Disablep.115EAN Two Label Combined Transmissionp.115EAN Two Label Minimum Readsp.116UPC/EAN Global Settingsp.117UPC/EAN Decoding Levelp.117UPC/EAN Correlationp.118UPC/EAN Price Weight Checkp.119UPC-A Minimum Readsp.120UPC/EAN Guard Insertionp.121UPC/EAN Stitch Exact Label Halvesp.121UPC/EAN Stitch Unlike Label Halvesp.122UPC/EAN Minimum Segment Lengthp.123Add-Onsp.125Optional Add-onsp.125Optional Add-On Timerp.127P2 Add-Ons Minimum Readsp.129P5 Add-Ons Minimum Readsp.130GS1-128 Add-Ons Minimum Readsp.131GS1 DataBarTM Omnidirectionalp.132GS1 DataBar Omnidirectional Enable/Disablep.132GS1 DataBar Omnidirectional GS1-128 Emulationp.132GS1 DataBar Omnidirectional Minimum Readsp.133GS1 DataBarTM Expandedp.134GS1 DataBar Expanded Enable/Disablep.134GS1 DataBar Expanded GS1-128 Emulationp.134GS1 DataBar Expanded Minimum Readsp.135GS1 DataBar Expanded Length Controlp.136GS1 DataBar Expanded Set Length 1p.136GS1 DataBar Expanded Set Length 2p.137GS1 DataBarTM Limitedp.138GS1 DataBar Limited Enable/Disablep.138GS1 DataBar Limited GS1-128 Emulationp.138GS1 DataBar Limited Minimum Readsp.139Code 39p.140Code 39 Enable/Disablep.140Code 39 Check Character Calculationp.141Code 39 Check Character Transmissionp.142Code 39 Start/Stop Character Transmissionp.142Code 39 Full ASCIIp.143Code 39 Quiet Zonesp.144Code 39 Minimum Readsp.145Code 39 Decoding Levelp.146Code 39 Length Controlp.147Code 39 Set Length 1p.148Code 39 Set Length 2p.149Code 39 Interdigit Ratiop.150Code 39 Character Correlationp.152Code 39 Stitchingp.152Code 32 (Italian Pharmaceutical)p.153Code 32 Enable/Disablep.153Code 32 Feature Setting Exceptionsp.153Code 32 Check Character Transmissionp.154Code 32 Start/Stop Character Transmissionp.154Code 39 CIP (French Pharmaceutical)p.155Code 39 CIP Enable/Disablep.155Code 128p.155Code 128 Enable/Disablep.155Expand Code 128 to Code 39p.156Code 128 Check Character Transmissionp.156Code 128 Function Character Transmissionp.157Code 128 Sub-Code Change Transmissionp.157Code 128 Quiet Zonesp.158Code 128 Minimum Readsp.159Code 128 Decoding Levelp.160Code 128 Length Controlp.161Code 128 Set Length 1p.162Code 128 Set Length 2p.163Code 128 Character Correlationp.164Code 128 Stitchingp.164GS1-128p.165GS1-128 Enablep.165Interleaved 2 of 5 (I 2 of 5)p.166I 2 of 5 Enable/Disablep.166I 2 of 5 Check Character Calculationp.167I 2 of 5 Check Character Transmissionp.168I 2 of 5 Minimum Readsp.169I 2 of 5 Decoding Levelp.170I 2 of 5 Length Controlp.171I 2 of 5 Set Length 1p.172I 2 of 5 Set Length 2p.173I 2 of 5 Character Correlationp.174I 2 of 5 Zero Patternp.174I 2 of 5 Stitchingp.175Interleaved 2 of 5 CIP HRp.175Interleaved 2 of 5 CIP HR Enable/Disablep.175Datalogic 2 of 5p.176Datalogic 2 of 5 Enable/Disablep.176Datalogic 2 of 5 Check Character Calculationp.176Datalogic 2 of 5 Check Character Transmissionp.177Datalogic 2 of 5 Minimum Readsp.177Datalogic 2 of 5 Decoding Levelp.178Datalogic 2 of 5 Length Controlp.178Datalogic 2 of 5 Set Length 1p.179Datalogic 2 of 5 Set Length 2p.180Datalogic 2 of 5 Interdigit Ratiop.181Datalogic 2 of 5 Character Correlationp.183Datalogic 2 of 5 Stitchingp.183Codabarp.184Codabar Enable/Disablep.184Codabar Check Character Calculationp.184Codabar Check Character Transmissionp.185Codabar Start/Stop Character Transmissionp.185Codabar Start/Stop Character Setp.186Codabar Start/Stop Character Matchp.187Codabar Quiet Zonesp.188Codabar Minimum Readsp.189Codabar Decoding Levelp.190Codabar Length Controlp.191Codabar Set Length 1p.192Codabar Set Length 2p.193Codabar Interdigit Ratiop.194Codabar Character Correlationp.196Codabar Stitchingp.196ABC Codabarp.197ABC Codabar Enable/Disablep.197ABC Codabar Concatenation Modep.197ABC Codabar Dynamic Concatenation Timeoutp.198ABC Codabar Force Concatenationp.198Code 11p.199Code 11 Enable/Disablep.199Code 11 Check Character Calculationp.200Code 11 Check Character Transmissionp.200Code 11 Minimum Readsp.201Code 11 Length Controlp.202Code 11 Set Length 1p.202Code 11 Set Length 2p.203Code 11 Interdigit Ratiop.204Code 11 Decoding Levelp.206Code 11 Character Correlationp.207Code 11 Stitchingp.207Standard 2 of 5p.208Standard 2 of 5 Enable/Disablep.208Standard 2 of 5 Check Character Calculationp.208Standard 2 of 5 Check Character Transmissionp.209Standard 2 of 5 Minimum Readsp.209Standard 2 of 5 Decoding Levelp.210Standard 2 of 5 Length Controlp.210Standard 2 of 5 Set Length 1p.211Standard 2 of 5 Set Length 2p.212Standard 2 of 5 Character Correlationp.213Standard 2 of 5 Stitchingp.213Industrial 2 of 5p.214Industrial 2 of 5 Enable/Disablep.214Industrial 2 of 5 Check Character Calculationp.214Industrial 2 of 5 Check Character Transmissionp.215Industrial 2 of 5 Length Controlp.215Industrial 2 of 5 Set Length 1p.216Industrial 2 of 5 Set Length 2p.217Industrial 2 of 5 Minimum Readsp.218Industrial 2 of 5 Stitchingp.219Industrial 2 of 5 Character Correlationp.219IATAp.220IATA Enable/Disablep.220IATA Check Character Transmissionp.220ISBT 128p.221ISBT 128 Concatenationp.221ISBT 128 Concatenation Modep.221ISBT 128 Dynamic Concatenation Timeoutp.222ISBT 128 Force Concatenationp.223ISBT 128 Advanced Concatenation Optionsp.223MSIp.224MSI Enable/Disablep.224MSI Check Character Calculationp.224MSI Check Character Transmissionp.225MSI Length Controlp.225MSI Set Length 1p.226MSI Set Length 2p.227MSI Minimum Readsp.228MSI Decoding Levelp.229Code 93p.230Code 93 Enable/Disablep.230Code 93 Check Character Calculationp.230Code 93 Check Character Transmissionp.231Code 93 Length Controlp.231Code 93 Set Length 1p.232Code 93 Set Length 2p.233Code 93 Minimum Readsp.234Code 93 Decoding Levelp.235Code 93 Quiet Zonesp.236Code 93 Stitchingp.237Code 93 Character Correlationp.237Codablock Fp.238Codablock F Enable/Disablep.238Codablock F EAN Enable/Disablep.238Codablock F AIM Checkp.239Codablock F Length Controlp.239Codablock F Set Length 1p.240Codablock F Set Length 2p.241Code 4p.242Code 4 Enable/Disablep.242Code 4 Check Character Transmissionp.242Code 4 Hex to Decimal Conversionp.243Code 5p.243Code 5 Enable/Disablep.243Code 5 Check Character Transmissionp.244Code 5 Hex to Decimal Conversionp.244Code 4 and Code 5 Common Configuration Itemsp.245Code 4 and 5 Decoding Levelp.245Code 4 and Code 5 Minimum Readsp.246Follett 2 of 5p.247Follett 2 of 5 Enable/Disablep.247BC412p.247BC412 Enable/Disablep.247BC412 Check Character Calculationp.248BC412 Minimum Readsp.248BC412 Decoding Levelp.249BC412 Length Controlp.250BC412 Set Length 1p.250BC412 Set Length 2p.251Plesseyp.252Plessey Enable/Disablep.252Plessey Check Character Calculationp.253Plessey Check Character Transmissionp.254Plessey Length Controlp.254Plessey Set Length 1p.255Plessey Set Length 2p.256Plessey Minimum Readsp.257Plessey Decoding Levelp.258Plessey Stitchingp.259Plessey Character Correlationp.259Referencesp.261RS-232 Parametersp.262RS-232 Onlyp.262RS-232/USB COM Parametersp.263Keyboard Interfacep.270Wedge Quiet Intervalp.270Intercharacter Delayp.271Intercode Delayp.272Data Formatp.273Data Editingp.273Global Prefix/Suffixp.274Global AIM IDp.275Label IDp.276Set Global Mid Label ID Character(s)p.280Character Conversionp.280Reading Parametersp.282Label Gone Timeoutp.282Good Read LED Durationp.283Scanning Featuresp.284Scan Modep.284Scanning Active Timep.285Flash On Timep.286Flash Off Timep.287Symbologiesp.288Decoding Levelsp.288Set Lengthp.288Technical Specificationsp.291Standard Cable Pinoutsp.293LED and Beeper Indicationsp.294Error Codesp.295Standard Defaultsp.297Default Exceptionsp.308Sample Bar Codesp.3111D Bar Codesp.311GS1 DataBar (RSS)p.313GS1 DataBar-14p.313Keypadp.315Scancode Tablesp.319Control Character Emulationp.319Interface Type PC AT PS/2 or USB-Keyboardp.320Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Modep.322Digital Interfacep.324IBM XTp.326Microsoft Windows Codepage 1252p.328ASCII Chartp.331
Page 78 of the Solis 842 user manual — Double Read Timeout
Page 78 · click to enlarge
Page 78

Enter/Exit Programming Mode Double Read Timeout

Double Read Timeout

To prevent a double read of the same label, the Double Read Timeout sets the minimum time allowed between reads of labels of the same symbology and data. If the unit reads a label and sees the same label again within the Double Read Timeout, the second read of the label will be ignored. Double Read Timeout does not apply to scan modes that require a trigger pull for each label that is read.

Solis 842 — Double Read Timeout diagram (page 78)
Fig. 71 · Double Read Timeout
Page 79 of the Solis 842 user manual — Double Read Timeout — continued
Page 79 · click to enlarge
Page 79
Solis 842 — Double Read Timeout diagram (page 79)
Fig. 72 · Double Read Timeout

Double Read Timeout — continued

Solis 842 — Double Read Timeout — continued diagram (page 79)
Fig. 73 · Double Read Timeout — continued
Page 80 of the Solis 842 user manual — CANCEL
Page 80 · click to enlarge
Page 80

Enter/Exit Programming Mode Label Gone Timeout

Label Gone Timeout

This feature sets the time after the last label segment is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55 seconds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a trigger pull for each label that is read. See "Label Gone Timeout" on page 272 for more detailed programming instructions.

$CSNLG

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Label Gone Timeout Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 016 = Timeout of 160 ms

~

Page 81 of the Solis 842 user manual — $CSLEN01
Page 81 · click to enlarge
Page 81

Power Save Mode Enter/Exit Programming Mode

Power Save Mode

When this feature is enabled, the reader will enter Power Save Mode (a lower power consumption state) after being idle (no scanner activity) for one second.

RS-232 and USB interfaces ONLY.

A reader having a Scan Mode setting of Object Sense, Stand Mode, Flashing, or Always On will not enter Power Save Mode. (The reader is always internally active when in these modes.)

NOTE

$CSLEN00

Power Save Mode = Disabled

$CSLEN01

Power Save Mode = Enabled

Page 82 of the Solis 842 user manual — NOTE
Page 82 · click to enlarge
Page 82

Enter/Exit Programming Mode Sleep Mode Timeout

Sleep Mode Timeout

Specifies the timeout value for the reader to enter Sleep Mode (a very low power consumption state).

RS-232 interface ONLY.

A reader having a Scan Mode setting of Object Sense, Stand Mode, Flashing, or Always On will not enter Sleep Mode. (The reader is always internally active when in these modes.)

NOTE

Solis 842 — NOTE diagram (page 82)
Fig. 74

Sleep Mode Timeout = 1 Minute 30 Seconds (90 Sec-

Page 83 of the Solis 842 user manual — $CBPPU01
Page 83 · click to enlarge
Page 83

LED and Beeper Indicators Enter/Exit Programming Mode

LED and Beeper Indicators

Power On Alert

Disables or enables the indication (from the Beeper) that the reader is receiving power.

$CBPPU00

Power On Alert = Disable (No Audible Indication)

$CBPPU01

Power On Alert = Power-up Beep

Page 84 of the Solis 842 user manual — NOTE
Page 84 · click to enlarge
Page 84

Enter/Exit Programming Mode LED and Beeper Indicators

Good Read: When to Indicate

This feature specifies when the reader will provide indication (beep and/or flash its green LED) upon successfully reading a bar code. Choices are:

  • Good Read = Indicate after decode
  • Good Read = Indicate after transmit
  • Good Read = Indicate after CTS goes inactive, then activ

This option, which uses CTS, is only valid for RS-232 interfaces.

NOTE

Solis 842 — NOTE diagram (page 84)
Fig. 75

Indicate Good Read = After CTS Goes Inactive, Then

e

Page 85 of the Solis 842 user manual — Good Read Beep Frequency
Page 85 · click to enlarge
Page 85
Solis 842 — Good Read Beep Type diagram (page 85)
Fig. 76 · Good Read Beep Type

Good Read Beep Type

Specifies whether the good read beep has a mono or bitonal beep sound.

Solis 842 — Good Read Beep Type diagram (page 85)
Fig. 77 · Good Read Beep Type

Good Read Beep Frequency

Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/tone.)

Solis 842 — Good Read Beep Frequency diagram (page 85)
Fig. 78 · Good Read Beep Frequency
Page 86 of the Solis 842 user manual — Good Read Beep Volume
Page 86 · click to enlarge
Page 86

Enter/Exit Programming Mode LED and Beeper Indicators

Good Read Beep Volume

Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels.

Solis 842 — Good Read Beep Volume diagram (page 86)
Fig. 79 · Good Read Beep Volume
Page 87 of the Solis 842 user manual — Good Read Beep Length
Page 87 · click to enlarge
Page 87
Solis 842 — Good Read Beep Length diagram (page 87)
Fig. 80 · Good Read Beep Length

Good Read Beep Length

Specifies the duration of a good read beep.

Solis 842 — Good Read Beep Length diagram (page 87)
Fig. 81 · Good Read Beep Length
Page 88 of the Solis 842 user manual — NOTE
Page 88 · click to enlarge
Page 88

Enter/Exit Programming Mode LED and Beeper Indicators

Good Read Beep Length — continued

Solis 842 — Good Read Beep Length — continued diagram (page 88)
Fig. 82 · Good Read Beep Length — continued

Illumination Control

Controls illumination during a good read beep.

Setting this configuration item to turn off illumination during the beep reduces the peak current drawn by the reader in some scanning modes.

NOTE

Solis 842 — NOTE diagram (page 88)
Fig. 83
Page 89 of the Solis 842 user manual — NOTE
Page 89 · click to enlarge
Page 89

LED and Beeper Indicators Enter/Exit Programming Mode

Good Read LED Duration

This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 0.1 to 25.5 seconds in 100ms increments. See "Good Read LED Duration" on page 273 for more detailed programming instructions.

$CLAGL

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Good Read LED Duration Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

020 = Good Read LED stays on for 2 seconds.

Indicators are dimmed during sleep.

NOTE

~

Page 90 of the Solis 842 user manual — Scan Mode
Page 90 · click to enlarge
Page 90

Enter/Exit Programming Mode Scanning Features

Scanning Features

Scan Mode

See "Scan Mode" on page 274 for more detailed programming instructions.

Solis 842 — Scan Mode diagram (page 90)
Fig. 84 · Scan Mode
Page 91 of the Solis 842 user manual — NOTE
Page 91 · click to enlarge
Page 91
Solis 842 — Stand Mode Triggered Timeout diagram (page 91)
Fig. 85 · Stand Mode Triggered Timeout

Stand Mode Triggered Timeout

This feature specifies the time to remain in Trigger Single mode after the trigger is pulled while in Stand Mode.

This timeout is only used when the Scan Mode is configured as Stand Mode.

NOTE

Solis 842 — NOTE diagram (page 91)
Fig. 86
Page 92 of the Solis 842 user manual — Stand Mode Triggered Timeout — continued
Page 92 · click to enlarge
Page 92

Enter/Exit Programming Mode Scanning Features

Stand Mode Triggered Timeout — continued

Solis 842 — Stand Mode Triggered Timeout — continued diagram (page 92)
Fig. 87 · Stand Mode Triggered Timeout — continued

Stand Mode Triggered Timeout = Switch back to Trig-

Page 93 of the Solis 842 user manual — DEFAULT 005 = Scanning is active for 5 Seconds
Page 93 · click to enlarge
Page 93
Solis 842 — Scanning Active Time diagram (page 93)
Fig. 88 · Scanning Active Time

Scanning Active Time

This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments. See "Scanning Active Time" on page 275 for more detailed programming instructions.

Solis 842 — Scanning Active Time diagram (page 93)
Fig. 89 · Scanning Active Time

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

DEFAULT 005 = Scanning is active for 5 Seconds

Stand Mode Flash

Enables/disables the LED flash when the reader is in Stand Mode.

Solis 842 — DEFAULT 005 = Scanning is active for 5 Seconds diagram (page 93)
Fig. 90 · DEFAULT 005 = Scanning is active for 5 Seconds
Page 94 of the Solis 842 user manual — DEFAULT 10 = Flash is ON for 1 Second
Page 94 · click to enlarge
Page 94

Enter/Exit Programming Mode Scanning Features

Flash On Time

This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. See "Flash On Time" on page 276 for more detailed programming instructions.

Solis 842 — Flash On Time diagram (page 94)
Fig. 91 · Flash On Time

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

DEFAULT 10 = Flash is ON for 1 Second

Flash Off Time

This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. See "Flash Off Time" on page 277 for more detailed programming instructions.

Solis 842 — DEFAULT 10 = Flash is ON for 1 Second diagram (page 94)
Fig. 92 · DEFAULT 10 = Flash is ON for 1 Second

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

Page 95 of the Solis 842 user manual — Stand Mode Sensitivity
Page 95 · click to enlarge
Page 95
Solis 842 — Stand Mode Sensitivity diagram (page 95)
Fig. 93 · Stand Mode Sensitivity

Stand Mode Sensitivity

Sets the sensitivity level for stand mode wakeup. Choices are low, medium and high.

Solis 842 — Stand Mode Sensitivity diagram (page 95)
Fig. 94 · Stand Mode Sensitivity
Page 96 of the Solis 842 user manual — NOTES
Page 96 · click to enlarge
Page 96

Enter/Exit Programming Mode Scanning Features

NOTES

Page 97 of the Solis 842 user manual — Standard Factory Settings for Symbologies
Page 97 · click to enlarge
Page 97

SYMBOLOGIES

Introduction

The reader supports the following symbologies (bar code types). Options for each symbology are included in this chapter.

  • UPC-A
  • Datalogic 2 of 5
  • UPC-E
  • Codabar
  • EAN 13
  • ABC Codabar
  • EAN 13 (JAN 13)
  • Code 11
  • EAN 8 (JAN 8)
  • Standard 2 of 5
  • Add-Ons
  • Industrial 2 of 5
  • GS1 DataBar TM Omnidirectional
  • IATA
  • GS1 DataBar TM Expanded
  • ISBT 128
  • GS1 DataBar TM Limited
  • MSI
  • Code 39
  • Code 93
  • Code 32 (Italian Pharmaceutical)
  • Codablock F
  • Code 39 CIP (French Pharmaceutical)
  • Code 4
  • Code 128
  • Code 5
  • GS1-128
  • Follett 2 of 5
  • Interleaved 2 of 5 (I 2 of 5)
  • BC412
  • Interleaved 2 of 5 CIP HR
  • Plessey

Standard Factory Settings for Symbologies

Default settings are indicated at each feature/option with a green arrow. Also reference Appendix B, Standard Defaults for a listing of the most widely used set of standard factory settings. That section also provides space to record any custom settings needed or implemented for your system.

Page 98 of the Solis 842 user manual — Coupon Control
Page 98 · click to enlarge
Page 98

Enter/Exit Programming Mode Disable All Symbologies

Disable All Symbologies

Scan this label to disable all symbologies.

Solis 842 — Disable All Symbologies diagram (page 98)
Fig. 95 · Disable All Symbologies

Coupon Control

This feature is used to control the method of processing coupon labels.

Options are:

  • Allow all — allow all coupon bar codes to be decoded
  • Enable only UPC/EAN — enables only UPC/EAN coupon decoding
  • Enable only GS1 DataBar — enables only GS1 DataBar coupon decoding

To set this feature:

1. Scan the Enter/Exit bar code.
2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the reader sees only the bar code you intend to scan.
3. Complete the programming sequence by scanning the Enter/Exit bar code.
Solis 842 — Coupon Control diagram (page 98)
Fig. 96 · Coupon Control
Page 99 of the Solis 842 user manual — UPC-A Check Character Transmission
Page 99 · click to enlarge
Page 99
Solis 842 — UPC-A diagram (page 99)
Fig. 97

UPC-A

The following options apply to the UPC-A symbology.

UPC-A Enable/Disable

When disabled, the reader will not read UPC-A bar codes.

Solis 842 — UPC-A Enable/Disable diagram (page 99)
Fig. 98 · UPC-A Enable/Disable

UPC-A Check Character Transmission

Enable this option to transmit the check character along with UPC-A bar code data.

Solis 842 — UPC-A Check Character Transmission diagram (page 99)
Fig. 99 · UPC-A Check Character Transmission
Page 100 of the Solis 842 user manual — UPC-A Number System Character Transmission
Page 100 · click to enlarge
Page 100

Enter/Exit Programming Mode UPC-A

Expand UPC-A to EAN-13

Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.

Solis 842 — Expand UPC-A to EAN-13 diagram (page 100)
Fig. 100 · Expand UPC-A to EAN-13

UPC-A Number System Character Transmission

This feature enables/disables transmission of the UPC-A number system character.

Solis 842 — UPC-A Number System Character Transmission diagram (page 100)
Fig. 101 · UPC-A Number System Character Transmission
Page 101 of the Solis 842 user manual — In-Store Minimum Reads
Page 101 · click to enlarge
Page 101
Solis 842 — In-Store Minimum Reads diagram (page 101)
Fig. 102 · In-Store Minimum Reads

In-Store Minimum Reads

This feature specifies the minimum number of consecutive times an in-store label must be decoded before it is accepted as good read.

In-store labels are defined as UPC-A labels with a number-system character of 2 or 4 as well as EAN 8 and EAN 13 labels with a Flag1 character of 2 or an EAN 13 label starting with the three characters '980'.

Solis 842 — In-Store Minimum Reads diagram (page 101)
Fig. 103 · In-Store Minimum Reads
Page 102 of the Solis 842 user manual — UPC-E Check Character Transmission
Page 102 · click to enlarge
Page 102

Enter/Exit Programming Mode UPC-E

UPC-E

The following options apply to the UPC-E symbology.

UPC-E Enable/Disable

When disabled, the reader will not read UPC-E bar codes.

Solis 842 — UPC-E Enable/Disable diagram (page 102)
Fig. 104 · UPC-E Enable/Disable

UPC-E Check Character Transmission

Enable this option to transmit the check character along with UPC-E bar code data.

Solis 842 — UPC-E Check Character Transmission diagram (page 102)
Fig. 105 · UPC-E Check Character Transmission
Page 103 of the Solis 842 user manual — Expand UPC-E to UPC-A
Page 103 · click to enlarge
Page 103
Solis 842 — Expand UPC-E to EAN-13 diagram (page 103)
Fig. 106 · Expand UPC-E to EAN-13

Expand UPC-E to EAN-13

Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.

Solis 842 — Expand UPC-E to EAN-13 diagram (page 103)
Fig. 107 · Expand UPC-E to EAN-13

Expand UPC-E to UPC-A

Expands UPC-E data to the UPC-A data format.

Solis 842 — Expand UPC-E to UPC-A diagram (page 103)
Fig. 108 · Expand UPC-E to UPC-A
Page 104 of the Solis 842 user manual — UPC-E Minimum Read
Page 104 · click to enlarge
Page 104

Enter/Exit Programming Mode UPC-E

UPC-E Number System Character Transmission

This feature enables/disables transmission of the UPC-E system number character.

Solis 842 — UPC-E Number System Character Transmission diagram (page 104)
Fig. 109 · UPC-E Number System Character Transmission

UPC-E Minimum Read

This feature specifies the minimum number of consecutive times a UPC-E label must be decoded before it is accepted as good read.

Solis 842 — UPC-E Minimum Read diagram (page 104)
Fig. 110 · UPC-E Minimum Read
Page 105 of the Solis 842 user manual — EAN 13 Check Character Transmission
Page 105 · click to enlarge
Page 105
Solis 842 — EAN 13 diagram (page 105)
Fig. 111

EAN 13

The following options apply to the EAN 13 (Jan 13) symbology.

EAN 13 Enable/Disable

When disabled, the reader will not read EAN 13/JAN 13 bar codes.

Solis 842 — EAN 13 Enable/Disable diagram (page 105)
Fig. 112 · EAN 13 Enable/Disable

EAN 13 Check Character Transmission

Enable this option to transmit the check character along with EAN 13 bar code data.

Solis 842 — EAN 13 Check Character Transmission diagram (page 105)
Fig. 113 · EAN 13 Check Character Transmission
Page 106 of the Solis 842 user manual — EAN-13 ISBN Conversion
Page 106 · click to enlarge
Page 106

Enter/Exit Programming Mode EAN 13

EAN-13 Flag 1 Character

Enables/disables transmission of an EAN/JAN13 Flag1 character. The Flag 1 character is the first character of the label.

Solis 842 — EAN-13 Flag 1 Character diagram (page 106)
Fig. 114 · EAN-13 Flag 1 Character

EAN-13 ISBN Conversion

This option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to ISBN labels.

Solis 842 — EAN-13 ISBN Conversion diagram (page 106)
Fig. 115 · EAN-13 ISBN Conversion
Page 107 of the Solis 842 user manual — EAN 13 Minimum Reads
Page 107 · click to enlarge
Page 107
Solis 842 — ISSN Enable/Disable diagram (page 107)
Fig. 116 · ISSN Enable/Disable

ISSN Enable/Disable

Enables/disables conversion of EAN/JAN13 Bookland labels starting with 977 to ISSN labels.

Solis 842 — ISSN Enable/Disable diagram (page 107)
Fig. 117 · ISSN Enable/Disable

EAN 13 Minimum Reads

This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as good read.

Solis 842 — EAN 13 Minimum Reads diagram (page 107)
Fig. 118 · EAN 13 Minimum Reads
Page 108 of the Solis 842 user manual — EAN 8 Check Character Transmission
Page 108 · click to enlarge
Page 108

Enter/Exit Programming Mode EAN 8

EAN 8

The following options apply to the EAN 8 (Jan 8) symbology.

EAN 8 Enable/Disable

When disabled, the reader will not read EAN 8/JAN 8 bar codes.

Solis 842 — EAN 8 Enable/Disable diagram (page 108)
Fig. 119 · EAN 8 Enable/Disable

EAN 8 Check Character Transmission

Enable this option to transmit the check character along with EAN 8 bar code data.

Solis 842 — EAN 8 Check Character Transmission diagram (page 108)
Fig. 120 · EAN 8 Check Character Transmission
Page 109 of the Solis 842 user manual — EAN 8 Both Guards Substitution
Page 109 · click to enlarge
Page 109
Solis 842 — Expand EAN 8 to EAN 13 diagram (page 109)
Fig. 121 · Expand EAN 8 to EAN 13

Expand EAN 8 to EAN 13

Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13.

Solis 842 — Expand EAN 8 to EAN 13 diagram (page 109)
Fig. 122 · Expand EAN 8 to EAN 13

EAN 8 Both Guards Substitution

Enables/disables the ability of the reader to find an EAN/JAN8 guard pattern in cases where the EAN/JAN8 margin makes the guard look like a character.

Solis 842 — EAN 8 Both Guards Substitution diagram (page 109)
Fig. 123 · EAN 8 Both Guards Substitution
Page 110 of the Solis 842 user manual — EAN 8 Guard Substitution
Page 110 · click to enlarge
Page 110

Enter/Exit Programming Mode EAN 8

EAN 8 Guard Insertion

Enables/disables the ability to insert a guard into an otherwise full-strike EAN 8 segment.

Solis 842 — EAN 8 Guard Insertion diagram (page 110)
Fig. 124 · EAN 8 Guard Insertion

EAN 8 Guard Substitution

Enables/disables the ability of the reader to substitute guard pattern for even parity 6 when an EAN/JAN8 label is presented.

Solis 842 — EAN 8 Guard Substitution diagram (page 110)
Fig. 125 · EAN 8 Guard Substitution
Page 111 of the Solis 842 user manual — EAN 8 Minimum Segment Length Block
Page 111 · click to enlarge
Page 111
Solis 842 — EAN 8 Minimum Segment Length Block diagram (page 111)
Fig. 126 · EAN 8 Minimum Segment Length Block

EAN 8 Minimum Segment Length Block

Specifies the minimum number of characters necessary in an EAN/JAN8 label segment in order for the reader to accept the segment for decoding.

Solis 842 — EAN 8 Minimum Segment Length Block diagram (page 111)
Fig. 127 · EAN 8 Minimum Segment Length Block
Page 112 of the Solis 842 user manual — EAN 8 Minimum Segment Length Block
Page 112 · click to enlarge
Page 112

Enter/Exit Programming Mode EAN 8

EAN 8 Minimum Segment Length Block — cont.

Solis 842 — EAN 8 Minimum Segment Length Block diagram (page 112)
Fig. 128 · EAN 8 Minimum Segment Length Block
Page 113 of the Solis 842 user manual — EAN 8 Minimum Reads
Page 113 · click to enlarge
Page 113
Solis 842 — EAN 8 Minimum Reads diagram (page 113)
Fig. 129 · EAN 8 Minimum Reads

EAN 8 Minimum Reads

This feature specifies the minimum number of consecutive times an EAN 8 (Jan 8) label must be decoded before it is accepted as good read.

Solis 842 — EAN 8 Minimum Reads diagram (page 113)
Fig. 130 · EAN 8 Minimum Reads
Page 114 of the Solis 842 user manual — NOTE
Page 114 · click to enlarge
Page 114

Enter/Exit Programming Mode EAN 8

EAN 8 Stitch Exact Label Halves

Enables/disables the ability to stitch exact EAN 8 label halves with no overlapping characters.

The label halves being stitched together to assemble a com- plete label must have the structure GddddC and CddddG.

NOTE

Solis 842 — NOTE diagram (page 114)
Fig. 131

EAN 8 Stitch Unlike Label Halves

Enables/disables the ability to stitch EAN 8 label halves together which may have differing characters in them.

The label structure must be GddddCd... and ..dCddddG. The characters dCd must match between the two segments.

NOTE

Solis 842 — NOTE diagram (page 114)
Fig. 132
Page 115 of the Solis 842 user manual — EAN Two Label Combined Transmission
Page 115 · click to enlarge
Page 115
Solis 842 — EAN Two Label diagram (page 115)
Fig. 133 · EAN Two Label

EAN Two Label

EAN Two Label Enable/Disable

When disabled, the reader will not read EAN two label bar codes.

Solis 842 — EAN Two Label Enable/Disable diagram (page 115)
Fig. 134 · EAN Two Label Enable/Disable

EAN Two Label Combined Transmission

This feature enables/disables transmission of an EAN two label pair as one label. The label type for EAN two label pairs is EAN 13.

Solis 842 — EAN Two Label Combined Transmission diagram (page 115)
Fig. 135 · EAN Two Label Combined Transmission
Page 116 of the Solis 842 user manual — EAN Two Label Minimum Reads
Page 116 · click to enlarge
Page 116

Enter/Exit Programming Mode EAN Two Label

EAN Two Label Minimum Reads

This feature specifies the minimum number of consecutive times an EAN two label bar code must be decoded before it is accepted as good read.

Solis 842 — EAN Two Label Minimum Reads diagram (page 116)
Fig. 136 · EAN Two Label Minimum Reads
Page 117 of the Solis 842 user manual — UPC/EAN Decoding Level
Page 117 · click to enlarge
Page 117
Solis 842 — UPC/EAN Global Settings diagram (page 117)
Fig. 137 · UPC/EAN Global Settings

UPC/EAN Global Settings

This section provides configuration settings for UPC-A, UPC-E, EAN 13 and EAN 8 symbologies, and affects all of these unless otherwise marked for each feature description.

UPC/EAN Decoding Level

Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.

Solis 842 — UPC/EAN Decoding Level diagram (page 117)
Fig. 138 · UPC/EAN Decoding Level
Page 118 of the Solis 842 user manual — $CUNCO01
Page 118 · click to enlarge
Page 118

Enter/Exit Programming Mode UPC/EAN Global Settings

UPC/EAN Correlation

When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the reader read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.

$CUNCO00

UPC/EAN Correlation = Disable

$CUNCO01

UPC/EAN Correlation = Enable

Page 119 of the Solis 842 user manual — UPC/EAN Price Weight Check
Page 119 · click to enlarge
Page 119
Solis 842 — UPC/EAN Price Weight Check diagram (page 119)
Fig. 139 · UPC/EAN Price Weight Check

UPC/EAN Price Weight Check

This feature enables/disables calculation and verification of price/weight check digits.

  • Disabled
  • Enable 4-digit price-weight check-digit calculation
  • Enable 5-digit price-weight check-digit calculation
  • Enable European 4-digit price-weight check-digit calculation
  • Enable European 5-digit price-weight check-digit calculation
Solis 842 — UPC/EAN Price Weight Check diagram (page 119)
Fig. 140 · UPC/EAN Price Weight Check

Options are

Page 120 of the Solis 842 user manual — UPC-A Minimum Reads
Page 120 · click to enlarge
Page 120

Enter/Exit Programming Mode UPC/EAN Global Settings

UPC-A Minimum Reads

This feature specifies the minimum number of consecutive times a UPC-A label must be decoded before it is accepted as good read.

Solis 842 — UPC-A Minimum Reads diagram (page 120)
Fig. 141 · UPC-A Minimum Reads
Page 121 of the Solis 842 user manual — NOTE
Page 121 · click to enlarge
Page 121
Solis 842 — UPC/EAN Guard Insertion diagram (page 121)
Fig. 142 · UPC/EAN Guard Insertion

UPC/EAN Guard Insertion

Enables/disables the ability to insert either a missing leading or trailing guard on an otherwise complete UPC-A/EAN-13 segment.

The segment must have the structure GddddddCdddddd or ddddddCddddddG.

NOTE

Solis 842 — NOTE diagram (page 121)
Fig. 143

UPC/EAN Stitch Exact Label Halves

Enables/disables the ability to stitch exact UPC-A/EAN 13 label halves with no overlapping characters.

The label halves being stitched together to assemble a com- plete label must have the structure GddddddC and CddddddG.

NOTE

Solis 842 — NOTE diagram (page 121)
Fig. 144
Page 122 of the Solis 842 user manual — NOTE
Page 122 · click to enlarge
Page 122

Enter/Exit Programming Mode UPC/EAN Global Settings

UPC/EAN Stitch Unlike Label Halves

Enables/disables the ability to stitch two UPC-A/EAN 13 label halves together that may have differing characters in them.

The label half structures must have the structure GddddddC and CddddddG. The characters dCd must match between the two segments.

NOTE

Solis 842 — NOTE diagram (page 122)
Fig. 145
Page 123 of the Solis 842 user manual — UPC/EAN Minimum Segment Length
Page 123 · click to enlarge
Page 123
Solis 842 — UPC/EAN Minimum Segment Length diagram (page 123)
Fig. 146 · UPC/EAN Minimum Segment Length

UPC/EAN Minimum Segment Length

Specifies the minimum number of characters necessary in an UPC/EAN/JAN label segment in order for the reader to accept the segment for decoding.

Solis 842 — UPC/EAN Minimum Segment Length diagram (page 123)
Fig. 147 · UPC/EAN Minimum Segment Length
Page 124 of the Solis 842 user manual — UPC/EAN Minimum Segment Length
Page 124 · click to enlarge
Page 124

Enter/Exit Programming Mode UPC/EAN Global Settings

UPC/EAN Minimum Segment Length — cont.

Solis 842 — UPC/EAN Minimum Segment Length diagram (page 124)
Fig. 148 · UPC/EAN Minimum Segment Length
Page 125 of the Solis 842 user manual — NOTE
Page 125 · click to enlarge
Page 125
Solis 842 — Add-Ons diagram (page 125)
Fig. 149 · Add-Ons

Add-Ons

The following features apply to optional add-ons.

Contact Customer Support for advanced programming of optional and conditional add-ons.

NOTE

Optional Add-ons

The reader can be enabled to optionally read the following add-ons (supplementals):

  • P2
  • P5
  • GS1-128

If a UPC/EAN base label and a an add-on are both decoded, the reader will transmit the base label and add-on. If a UPC/ EAN base label is decoded without an add-on, the base label will be transmitted without an add-on.

NOTE

Conditional add-on settings (if enabled) are considered by the reader before optional add-on settings.

Solis 842 — NOTE diagram (page 125)
Fig. 150
Page 126 of the Solis 842 user manual — Add-Ons
Page 126 · click to enlarge
Page 126

Enter/Exit Programming Mode Add-Ons

Optional Add-ons — cont.

Solis 842 — Add-Ons diagram (page 126)
Fig. 151 · Add-Ons
Page 127 of the Solis 842 user manual — Optional Add-On Timer
Page 127 · click to enlarge
Page 127
Solis 842 — Optional Add-On Timer diagram (page 127)
Fig. 152 · Optional Add-On Timer

Optional Add-On Timer

This option sets the time the reader will look for an add-on when an add-on fragment has been seen and optional add-ons are enabled.

Solis 842 — Optional Add-On Timer diagram (page 127)
Fig. 153 · Optional Add-On Timer
Page 128 of the Solis 842 user manual — Optional Add-On Timer
Page 128 · click to enlarge
Page 128

Enter/Exit Programming Mode Add-Ons

Optional Add-On Timer — cont.

Solis 842 — Optional Add-On Timer diagram (page 128)
Fig. 154 · Optional Add-On Timer
Page 129 of the Solis 842 user manual — P2 Add-Ons Minimum Reads
Page 129 · click to enlarge
Page 129
Solis 842 — P2 Add-Ons Minimum Reads diagram (page 129)
Fig. 155 · P2 Add-Ons Minimum Reads

P2 Add-Ons Minimum Reads

This feature specifies the minimum number of times a P2 add-on must be read before it is marked as valid and then combined with a base label.

Solis 842 — P2 Add-Ons Minimum Reads diagram (page 129)
Fig. 156 · P2 Add-Ons Minimum Reads
Page 130 of the Solis 842 user manual — P5 Add-Ons Minimum Reads
Page 130 · click to enlarge
Page 130

Enter/Exit Programming Mode Add-Ons

P5 Add-Ons Minimum Reads

This feature specifies the minimum number of times a P5 add-on must be read before it is marked as valid and then combined with a base label.

Solis 842 — P5 Add-Ons Minimum Reads diagram (page 130)
Fig. 157 · P5 Add-Ons Minimum Reads
Page 131 of the Solis 842 user manual — GS1-128 Add-Ons Minimum Reads
Page 131 · click to enlarge
Page 131
Solis 842 — GS1-128 Add-Ons Minimum Reads diagram (page 131)
Fig. 158 · GS1-128 Add-Ons Minimum Reads

GS1-128 Add-Ons Minimum Reads

This feature specifies the minimum number of times an GS1-128 add-on must be read before it is marked as valid and then combined with a base label.

Solis 842 — GS1-128 Add-Ons Minimum Reads diagram (page 131)
Fig. 159 · GS1-128 Add-Ons Minimum Reads
Page 132 of the Solis 842 user manual — GS1 DataBar Omnidirectional GS1-128 Emulation
Page 132 · click to enlarge
Page 132

Enter/Exit Programming Mode GS1 DataBarTM Omnidirectional

GS1 DataBar TM Omnidirectional

The following options apply to the GS1 DataBar Omnidirectional (formerly RSS-14) symbology.

GS1 DataBar Omnidirectional Enable/Disable

When disabled, the reader will not read GS1 DataBar Omnidirectional bar codes.

Solis 842 — GS1 DataBar Omnidirectional Enable/Disable diagram (page 132)
Fig. 160 · GS1 DataBar Omnidirectional Enable/Disable

GS1 DataBar Omnidirectional GS1-128 Emulation

When enabled, GS1 DataBar Omnidirectional bar codes will be translated to the GS1-128 label data format.

Solis 842 — GS1 DataBar Omnidirectional GS1-128 Emulation diagram (page 132)
Fig. 161 · GS1 DataBar Omnidirectional GS1-128 Emulation
Page 133 of the Solis 842 user manual — GS1 DataBar Omnidirectional Minimum Reads
Page 133 · click to enlarge
Page 133
Solis 842 — GS1 DataBar Omnidirectional Minimum Reads diagram (page 133)
Fig. 162 · GS1 DataBar Omnidirectional Minimum Reads

GS1 DataBar Omnidirectional Minimum Reads

This feature specifies the minimum number of consecutive times a GS1 DataBar Omnidirectional label must be decoded before it is accepted as good read.

Solis 842 — GS1 DataBar Omnidirectional Minimum Reads diagram (page 133)
Fig. 163 · GS1 DataBar Omnidirectional Minimum Reads
Page 134 of the Solis 842 user manual — GS1 DataBar Expanded GS1-128 Emulation
Page 134 · click to enlarge
Page 134

Enter/Exit Programming Mode GS1 DataBarTM Expanded

GS1 DataBar TM Expanded

The following options apply to the GS1 DataBar Expanded (formerly RSS Expanded) symbology.

GS1 DataBar Expanded Enable/Disable

When disabled, the reader will not read GS1 DataBar Expanded bar codes.

Solis 842 — GS1 DataBar Expanded Enable/Disable diagram (page 134)
Fig. 164 · GS1 DataBar Expanded Enable/Disable

GS1 DataBar Expanded GS1-128 Emulation

When enabled, GS1 DataBar Expanded bar codes will be translated to the GS1-128 label data format.

Solis 842 — GS1 DataBar Expanded GS1-128 Emulation diagram (page 134)
Fig. 165 · GS1 DataBar Expanded GS1-128 Emulation
Page 135 of the Solis 842 user manual — GS1 DataBar Expanded Minimum Reads
Page 135 · click to enlarge
Page 135
Solis 842 — GS1 DataBar Expanded Minimum Reads diagram (page 135)
Fig. 166 · GS1 DataBar Expanded Minimum Reads

GS1 DataBar Expanded Minimum Reads

This feature specifies the minimum number of consecutive times a GS1 DataBar Expanded label must be decoded before it is accepted as good read.

Solis 842 — GS1 DataBar Expanded Minimum Reads diagram (page 135)
Fig. 167 · GS1 DataBar Expanded Minimum Reads
Page 136 of the Solis 842 user manual — GS1 DataBar Expanded Set Length 1
Page 136 · click to enlarge
Page 136

Enter/Exit Programming Mode GS1 DataBarTM Expanded

GS1 DataBar Expanded Length Control

This feature specifies either variable length decoding or fixed length decoding for the GS1 DataBar Expanded symbology.

Variable Length: For variable-length decoding, a minimum length may be set.

Fixed Length: For fixed-length decoding, two different lengths may be set.

Solis 842 — GS1 DataBar Expanded Length Control diagram (page 136)
Fig. 168 · GS1 DataBar Expanded Length Control

GS1 DataBar Expanded Set Length 1

This feature specifies one of the bar code lengths for GS1 DataBar Expanded Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.

The length can be set from 1 to 74 characters. See "Set Length 1" on page 278 for more detailed programming instructions.

Solis 842 — GS1 DataBar Expanded Set Length 1 diagram (page 136)
Fig. 169 · GS1 DataBar Expanded Set Length 1

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

Page 137 of the Solis 842 user manual — CANCEL
Page 137 · click to enlarge
Page 137

GS1 DataBarTM Expanded Enter/Exit Programming Mode

GS1 DataBar Expanded Set Length 2

This feature specifies one of the bar code lengths for GS1 DataBar Expanded Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.

The length can be set from 1 to 74 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.

$CXBL2

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select GS1 DataBar Expanded Set Length 2 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 74 = Length 2 is 74 Characters

~

Page 138 of the Solis 842 user manual — GS1 DataBar Limited GS1-128 Emulation
Page 138 · click to enlarge
Page 138

Enter/Exit Programming Mode GS1 DataBarTM Limited

GS1 DataBar TM Limited

The following options apply to the GS1 DataBar Limited (formerly RSS Limited) symbology.

GS1 DataBar Limited Enable/Disable

When disabled, the reader will not read GS1 DataBar Limited bar codes.

Solis 842 — GS1 DataBar Limited Enable/Disable diagram (page 138)
Fig. 170 · GS1 DataBar Limited Enable/Disable

GS1 DataBar Limited GS1-128 Emulation

When enabled, GS1 DataBar Limited bar codes will be translated to the GS1-128 label data format.

Solis 842 — GS1 DataBar Limited GS1-128 Emulation diagram (page 138)
Fig. 171 · GS1 DataBar Limited GS1-128 Emulation
Page 139 of the Solis 842 user manual — GS1 DataBar Limited Minimum Reads
Page 139 · click to enlarge
Page 139
Solis 842 — GS1 DataBar Limited Minimum Reads diagram (page 139)
Fig. 172 · GS1 DataBar Limited Minimum Reads

GS1 DataBar Limited Minimum Reads

This feature specifies the minimum number of consecutive times a GS1 DataBar Limited label must be decoded before it is accepted as good read.

Solis 842 — GS1 DataBar Limited Minimum Reads diagram (page 139)
Fig. 173 · GS1 DataBar Limited Minimum Reads
Page 140 of the Solis 842 user manual — $CC3EN01
Page 140 · click to enlarge
Page 140

Enter/Exit Programming Mode Code 39

Code 39

The following options apply to the Code 39 symbology.

Code 39 Enable/Disable

When disabled, the reader will not read Code 39 bar codes.

$CC3EN00

Code 39 = Disable

$CC3EN01

Code 39 = Enable

Page 141 of the Solis 842 user manual — Code 39 Check Character Calculation
Page 141 · click to enlarge
Page 141
Solis 842 — Code 39 Check Character Calculation diagram (page 141)
Fig. 174 · Code 39 Check Character Calculation

Code 39 Check Character Calculation

Enable this option to enable/disable calculation and verification of an optional Code 39 check character. When disabled, any check character in the label is treated as a data character.

Solis 842 — Code 39 Check Character Calculation diagram (page 141)
Fig. 175 · Code 39 Check Character Calculation

Code 39 Check Character Calculation = Calculate Mod 7

Code 39 Check Character Calculation = Enable Italian Post

Page 142 of the Solis 842 user manual — Code 39 Start/Stop Character Transmission
Page 142 · click to enlarge
Page 142

Enter/Exit Programming Mode Code 39

Code 39 Check Character Transmission

Enable this option to transmit the check character along with Code 39 bar code data.

Solis 842 — Code 39 Check Character Transmission diagram (page 142)
Fig. 176 · Code 39 Check Character Transmission

Code 39 Start/Stop Character Transmission

Enable this option to enable/disable transmission of Code 39 start and stop characters.

Solis 842 — Code 39 Start/Stop Character Transmission diagram (page 142)
Fig. 177 · Code 39 Start/Stop Character Transmission
Page 143 of the Solis 842 user manual — Code 39 Full ASCII
Page 143 · click to enlarge
Page 143
Solis 842 — Code 39 Full ASCII diagram (page 143)
Fig. 178 · Code 39 Full ASCII

Code 39 Full ASCII

In Code 39 decoding, this enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters.

Solis 842 — Code 39 Full ASCII diagram (page 143)
Fig. 179 · Code 39 Full ASCII
Page 144 of the Solis 842 user manual — Code 39 Quiet Zones
Page 144 · click to enlarge
Page 144

Enter/Exit Programming Mode Code 39

Code 39 Quiet Zones

This feature specifies the number of quiet zones for Code 39 labels. Quiet zones are blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label.

Solis 842 — Code 39 Quiet Zones diagram (page 144)
Fig. 180 · Code 39 Quiet Zones

Code 39 Quiet Zones = Quiet Zone on one side

Code 39 Quiet Zones = Quiet Zones on two sides

Code 39 Quiet Zones = Virtual Quiet Zones on two sides

Code 39 Quiet Zones = Small Quiet Zones on two sides

Page 145 of the Solis 842 user manual — Code 39 Minimum Reads
Page 145 · click to enlarge
Page 145
Solis 842 — Code 39 Minimum Reads diagram (page 145)
Fig. 181 · Code 39 Minimum Reads

Code 39 Minimum Reads

This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read.

Solis 842 — Code 39 Minimum Reads diagram (page 145)
Fig. 182 · Code 39 Minimum Reads
Page 146 of the Solis 842 user manual — Code 39 Decoding Level
Page 146 · click to enlarge
Page 146

Enter/Exit Programming Mode Code 39

Code 39 Decoding Level

Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.

Solis 842 — Code 39 Decoding Level diagram (page 146)
Fig. 183 · Code 39 Decoding Level
Page 147 of the Solis 842 user manual — $CC3LC01
Page 147 · click to enlarge
Page 147

Code 39 Enter/Exit Programming Mode

Code 39 Length Control

This feature specifies either variable length decoding or fixed length decoding for the Code 39 symbology.

Variable Length: For variable length decoding, a minimum and maximum length may be set.

Fixed Length: For fixed length decoding, two different lengths may be set.

$CC3LC00

Code 39 Length Control = Variable Length

$CC3LC01

Code 39 Length Control = Fixed Length

Page 148 of the Solis 842 user manual — CANCEL
Page 148 · click to enlarge
Page 148

Enter/Exit Programming Mode Code 39

Code 39 Set Length 1

This feature specifies one of the bar code lengths for Code 39 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.

The length can be set from 0 to 50 characters. See "Set Length 1" on page 278 for more detailed programming instructions.

$CC3L1

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Code 39 Set Length 1 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 02 = Length 1 is 2 Characters

~

Page 149 of the Solis 842 user manual — CANCEL
Page 149 · click to enlarge
Page 149

Code 39 Enter/Exit Programming Mode

Code 39 Set Length 2

This feature specifies one of the bar code lengths for Code 39 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.

The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.

$CC3L2

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Code 39 Length 2 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 50 = Length 2 is 50 Characters

~

Page 150 of the Solis 842 user manual — Code 39 Interdigit Ratio
Page 150 · click to enlarge
Page 150

Enter/Exit Programming Mode Code 39

Code 39 Interdigit Ratio

This feature specifies the ratio between an intercharacter space and module for Code 39 labels.

Solis 842 — Code 39 Interdigit Ratio diagram (page 150)
Fig. 184 · Code 39 Interdigit Ratio
Page 151 of the Solis 842 user manual — Code 39 Interdigit Ratio
Page 151 · click to enlarge
Page 151
Solis 842 — Code 39 Interdigit Ratio diagram (page 151)
Fig. 185 · Code 39 Interdigit Ratio

Code 39 Interdigit Ratio — cont.

Solis 842 — Code 39 Interdigit Ratio diagram (page 151)
Fig. 186 · Code 39 Interdigit Ratio
Page 152 of the Solis 842 user manual — NOTE
Page 152 · click to enlarge
Page 152

Enter/Exit Programming Mode Code 39

Code 39 Character Correlation

When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the reader read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.

Solis 842 — Code 39 Character Correlation diagram (page 152)
Fig. 187 · Code 39 Character Correlation

Code 39 Stitching

This option enables/disables stitching for Code 39 labels. When parts of a Code 39 bar code are presented to the reader with this feature enabled, the bar code parts will be assembled by the reader’s software, and the data will be decoded if all bar code proofing requirements are met.

This feature is available only on the TD1130 model.

NOTE

Solis 842 — NOTE diagram (page 152)
Fig. 188
Page 153 of the Solis 842 user manual — NOTE
Page 153 · click to enlarge
Page 153
Solis 842 — Code 32 (Italian Pharmaceutical) diagram (page 153)
Fig. 189 · Code 32 (Italian Pharmaceutical)

Code 32 (Italian Pharmaceutical)

The following options apply to the Code 32 symbology.

Code 32 Enable/Disable

When disabled, the reader will not read Code 32 bar codes.

Solis 842 — Code 32 Enable/Disable diagram (page 153)
Fig. 190 · Code 32 Enable/Disable

Code 32 Feature Setting Exceptions

The following features are set for Code 32 by using these Code 39 settings:

"Code 39 Quiet Zones" on page 134 "Code 39 Minimum Reads" on page 135 "Code 39 Decoding Level" on page 136 "Code 39 Interdigit Ratio" on page 140 "Code 39 Character Correlation" on page 142 "Code 39 Stitching" on page 142

NOTE

Page 154 of the Solis 842 user manual — Code 32 Start/Stop Character Transmission
Page 154 · click to enlarge
Page 154

Enter/Exit Programming Mode Code 32 (Italian Pharmaceutical)

Code 32 Check Character Transmission

Enable this option to transmit the check character along with Code 32 bar code data.

Solis 842 — Code 32 Check Character Transmission diagram (page 154)
Fig. 191 · Code 32 Check Character Transmission

Code 32 Start/Stop Character Transmission

This option enables/disable transmission of Code 32 start and stop characters.

Solis 842 — Code 32 Start/Stop Character Transmission diagram (page 154)
Fig. 192 · Code 32 Start/Stop Character Transmission
Page 155 of the Solis 842 user manual — Code 128 Enable/Disable
Page 155 · click to enlarge
Page 155
Solis 842 — Code 39 CIP (French Pharmaceutical) diagram (page 155)
Fig. 193 · Code 39 CIP (French Pharmaceutical)

Code 39 CIP (French Pharmaceutical)

The following options apply to the Code 39 CIP symbology.

Code 39 CIP Enable/Disable

Enables/Disables ability of the reader to decode Code 39 CIP labels.

Solis 842 — Code 39 CIP Enable/Disable diagram (page 155)
Fig. 194 · Code 39 CIP Enable/Disable

Code 128

The following options apply to the Code 128 symbology.

Code 128 Enable/Disable

When disabled, the reader will not read Code 128 bar codes.

Solis 842 — Code 128 Enable/Disable diagram (page 155)
Fig. 195 · Code 128 Enable/Disable
Page 156 of the Solis 842 user manual — Code 128 Check Character Transmission
Page 156 · click to enlarge
Page 156

Enter/Exit Programming Mode Code 128

Expand Code 128 to Code 39

This feature enables/disables expansion of Code 128 labels to Code 39 labels. When enabled, the label identifier for a Code 128 label shall be set to Code 39 and all Code 39 formatting control shall be applied to the label.

Solis 842 — Expand Code 128 to Code 39 diagram (page 156)
Fig. 196 · Expand Code 128 to Code 39

Code 128 Check Character Transmission

Enable this option to transmit the check character along with Code 128 bar code data.

Solis 842 — Code 128 Check Character Transmission diagram (page 156)
Fig. 197 · Code 128 Check Character Transmission
Page 157 of the Solis 842 user manual — Code 128 Sub-Code Change Transmission
Page 157 · click to enlarge
Page 157
Solis 842 — Code 128 Function Character Transmission diagram (page 157)
Fig. 198 · Code 128 Function Character Transmission

Code 128 Function Character Transmission

Enables/disables transmission of Code128 function characters 1, 2, 3, and 4.

It is recommended that this setting be disabled for all interfaces except Wand Emulation.

NOTE

Solis 842 — NOTE diagram (page 157)
Fig. 199

Code 128 Sub-Code Change Transmission

Enables/disables the transmission of “Sub-Code exchange” characters (NOT transmitted by standard decoding).

Solis 842 — Code 128 Sub-Code Change Transmission diagram (page 157)
Fig. 200 · Code 128 Sub-Code Change Transmission
Page 158 of the Solis 842 user manual — Code 128 Quiet Zones
Page 158 · click to enlarge
Page 158

Enter/Exit Programming Mode Code 128

Code 128 Quiet Zones

This feature specifies the number of quiet zones for Code 128 labels. Quiet zones are blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label.

Solis 842 — Code 128 Quiet Zones diagram (page 158)
Fig. 201 · Code 128 Quiet Zones

Code 128 Quiet Zones = Quiet Zone on one side

Code 128 Quiet Zones = Quiet Zones on two sides

Code 128 Quiet Zones = Virtual Quiet Zones on two

Page 159 of the Solis 842 user manual — Code 128 Minimum Reads
Page 159 · click to enlarge
Page 159
Solis 842 — Code 128 Minimum Reads diagram (page 159)
Fig. 202 · Code 128 Minimum Reads

Code 128 Minimum Reads

This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read.

Solis 842 — Code 128 Minimum Reads diagram (page 159)
Fig. 203 · Code 128 Minimum Reads
Page 160 of the Solis 842 user manual — Code 128 Decoding Level
Page 160 · click to enlarge
Page 160

Enter/Exit Programming Mode Code 128

Code 128 Decoding Level

Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.

Solis 842 — Code 128 Decoding Level diagram (page 160)
Fig. 204 · Code 128 Decoding Level
Page 161 of the Solis 842 user manual — $CC8LC01
Page 161 · click to enlarge
Page 161

Code 128 Enter/Exit Programming Mode

Code 128 Length Control

This feature specifies either variable length decoding or fixed length decoding for the Code 128 symbology.

Variable Length: For variable length decoding, a minimum and maximum length may be set.

Fixed Length: For fixed length decoding, two different lengths may be set.

$CC8LC00

Code 128 Length Control = Variable Length

$CC8LC01

Code 128 Length Control = Fixed Length

Page 162 of the Solis 842 user manual — CANCEL
Page 162 · click to enlarge
Page 162

Enter/Exit Programming Mode Code 128

Code 128 Set Length 1

This feature specifies one of the bar code lengths for Code 128 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.

The length can be set from 1 to 80 characters. See "Set Length 1" on page 278 for more detailed programming instructions.

$CC8L1

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Code 128 Set Length 1 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 01 = Length 1 is 1 Character

~

Page 163 of the Solis 842 user manual — CANCEL
Page 163 · click to enlarge
Page 163

Code 128 Enter/Exit Programming Mode

Code 128 Set Length 2

This feature specifies one of the bar code lengths for Code 128 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.

The length can be set from 1 to 80 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.

$CC8L2

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Code 128 Length 2 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 80 = Length 2 is 80 Characters

~

Page 164 of the Solis 842 user manual — NOTE
Page 164 · click to enlarge
Page 164

Enter/Exit Programming Mode Code 128

Code 128 Character Correlation

When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the reader read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.

Solis 842 — Code 128 Character Correlation diagram (page 164)
Fig. 205 · Code 128 Character Correlation

Code 128 Stitching

This option enables/disables stitching for Code 128 labels. When parts of a Code 128 bar code are presented to the reader with this feature enabled, the bar code parts will be assembled by the reader’s software, and the data will be decoded if all bar code proofing requirements are met.

This feature is available only on the TD1130 model.

NOTE

Solis 842 — NOTE diagram (page 164)
Fig. 206
Page 165 of the Solis 842 user manual — GS1-128 Enable
Page 165 · click to enlarge
Page 165
Solis 842 — GS1-128 diagram (page 165)
Fig. 207

GS1-128

The following options apply to the GS1-128 symbology. (Also known as USS-128, GTIN-128, UCC-128.)

GS1-128 Enable

This option enables/disables the ability of the reader to translate GS1-128 labels to the GS1-128 data format. Options are:

  • Transmit GS1-128 labels in Code 128 data format.
  • Transmit GS1-128 labels in GS1-128 data format.
  • Do not transmit GS1-128 labels.
Solis 842 — GS1-128 Enable diagram (page 165)
Fig. 208 · GS1-128 Enable
Page 166 of the Solis 842 user manual — $CI2EN01
Page 166 · click to enlarge
Page 166

Enter/Exit Programming Mode Interleaved 2 of 5 (I 2 of 5)

Interleaved 2 of 5 (I 2 of 5)

The following options apply to the I 2 of 5 symbology.

I 2 of 5 Enable/Disable

When disabled, the reader will not read I 2 of 5 bar codes.

$CI2EN00

I 2 of 5 = Disable

$CI2EN01

I 2 of 5 = Enable

Page 167 of the Solis 842 user manual — I 2 of 5 Check Character Calculation
Page 167 · click to enlarge
Page 167
Solis 842 — I 2 of 5 Check Character Calculation diagram (page 167)
Fig. 209 · I 2 of 5 Check Character Calculation

Interleaved 2 of 5 (I 2 of 5) Enter/Exit Programming Mode

I 2 of 5 Check Character Calculation

This option enables/disables calculation and verification of an optional I 2 of 5 check character.

Solis 842 — I 2 of 5 Check Character Calculation diagram (page 167)
Fig. 210 · I 2 of 5 Check Character Calculation

I 2 of 5 Check Char Calc = Disable

I 2 of 5 Check Char Calc = Check Standard

I 2 of 5 Check Char Calc = Check German Parcel

I 2 of 5 Check Char Calc = Check DHL

I 2 of 5 Check Char Calc = Check Daimler Chrysler

I 2 of 5 Check Char Calc = Check Bosch

I 2 of 5 Check Character Calculation = Check Italian Post

When disabled, any check character in label is treated as a data character.

Page 168 of the Solis 842 user manual — NOTE
Page 168 · click to enlarge
Page 168

Enter/Exit Programming Mode Interleaved 2 of 5 (I 2 of 5)

I 2 of 5 Check Character Transmission

Enable this option to transmit the check character along with I 2 of 5 bar code data.

This feature is valid only when I 2 of 5 Check Character Calculation is enabled.

NOTE

Solis 842 — NOTE diagram (page 168)
Fig. 211

I 2 of 5 Check Character Transmission = Don’t Send

I 2 of 5 Check Character Transmission = Send

Page 169 of the Solis 842 user manual — I 2 of 5 Minimum Reads
Page 169 · click to enlarge
Page 169
Solis 842 — I 2 of 5 Minimum Reads diagram (page 169)
Fig. 212 · I 2 of 5 Minimum Reads

Interleaved 2 of 5 (I 2 of 5) Enter/Exit Programming Mode

I 2 of 5 Minimum Reads

This feature specifies the minimum number of consecutive times an I 2 of 5 label must be decoded before it is accepted as good read.

Solis 842 — I 2 of 5 Minimum Reads diagram (page 169)
Fig. 213 · I 2 of 5 Minimum Reads
Page 170 of the Solis 842 user manual — NOTE
Page 170 · click to enlarge
Page 170

Enter/Exit Programming Mode Interleaved 2 of 5 (I 2 of 5)

I 2 of 5 Decoding Level

This configuration item applies to Interleaved 2 of 5, Datalogic 2 of 5 and Standard 2 of 5.

NOTE

Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.

Solis 842 — NOTE diagram (page 170)
Fig. 214
Page 171 of the Solis 842 user manual — $CI2LC01
Page 171 · click to enlarge
Page 171

Interleaved 2 of 5 (I 2 of 5) Enter/Exit Programming Mode

I 2 of 5 Length Control

This feature specifies either variable length decoding or fixed length decoding for the I 2 of 5 symbology.

Variable Length: For variable length decoding, a minimum and maximum length may be set.

Fixed Length: For fixed length decoding, two different lengths may be set.

$CI2LC00

I 2 of 5 Length Control = Variable Length

$CI2LC01

I 2 of 5 Length Control = Fixed Length

Page 172 of the Solis 842 user manual — CANCEL
Page 172 · click to enlarge
Page 172

Enter/Exit Programming Mode Interleaved 2 of 5 (I 2 of 5)

I 2 of 5 Set Length 1

This feature specifies one of the bar code lengths for I 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. The length includes the bar code’s check and data characters.

The length can be set from 2 to 50 characters in increments of two. See "Set Length 1" on page 278 for more detailed programming instructions.

$CI2L1

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select I 2 of 5 Length 1 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 06 = Length 1 is 6 Characters

~

Page 173 of the Solis 842 user manual — CANCEL
Page 173 · click to enlarge
Page 173

Interleaved 2 of 5 (I 2 of 5) Enter/Exit Programming Mode

I 2 of 5 Set Length 2

This feature specifies one of the bar code lengths for I 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the bar code’s check and data characters.

The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.

$CI2L2

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select I 2 of 5 Length 2 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 50 = Length 2 is 50 Characters

~

Page 174 of the Solis 842 user manual — I 2 of 5 Zero Pattern
Page 174 · click to enlarge
Page 174

Enter/Exit Programming Mode Interleaved 2 of 5 (I 2 of 5)

I 2 of 5 Character Correlation

When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the reader read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.

Solis 842 — I 2 of 5 Character Correlation diagram (page 174)
Fig. 215 · I 2 of 5 Character Correlation

I 2 of 5 Zero Pattern

Enables/disables ZERO-Digit decoding. This character does not represent any cipher. It allows encoding of an odd number of ciphers with Interleaved 2 of 5. It must be enabled to decode Code 2 of 5 CIP/HR.

Solis 842 — I 2 of 5 Zero Pattern diagram (page 174)
Fig. 216 · I 2 of 5 Zero Pattern
Page 175 of the Solis 842 user manual — Interleaved 2 of 5 CIP HR Enable/Disable
Page 175 · click to enlarge
Page 175
Solis 842 — I 2 of 5 Stitching diagram (page 175)
Fig. 217 · I 2 of 5 Stitching

Interleaved 2 of 5 CIP HR Enter/Exit Programming Mode

I 2 of 5 Stitching

This option enables/disables stitching for I 2 of 5 labels. When parts of a I 2 of 5 bar code are presented to the reader with this feature enabled, the bar code parts will be assembled by the reader’s software, and the data will be decoded if all bar code proofing requirements are met.

This feature is available only on the TD1130 model.

NOTE

Solis 842 — NOTE diagram (page 175)
Fig. 218

Interleaved 2 of 5 CIP HR

The following options apply to the Interleaved 2 of 5 CIP HR symbology.

Interleaved 2 of 5 CIP HR Enable/Disable

Enables/Disables ability of reader to decode Interleaved 2 of 5 CIP HR labels.

Solis 842 — Interleaved 2 of 5 CIP HR Enable/Disable diagram (page 175)
Fig. 219 · Interleaved 2 of 5 CIP HR Enable/Disable
Page 176 of the Solis 842 user manual — Datalogic 2 of 5 Check Character Calculation
Page 176 · click to enlarge
Page 176

Enter/Exit Programming Mode Datalogic 2 of 5

Datalogic 2 of 5

The following options apply to the Datalogic 2 of 5 symbology.

Datalogic 2 of 5 Enable/Disable

When disabled, the reader will not read Datalogic 2 of 5 bar codes.

Solis 842 — Datalogic 2 of 5 Enable/Disable diagram (page 176)
Fig. 220 · Datalogic 2 of 5 Enable/Disable

Datalogic 2 of 5 Check Character Calculation

This option enables/disables calculation and verification of an optional Datalogic 2 of 5 check character.

Solis 842 — Datalogic 2 of 5 Check Character Calculation diagram (page 176)
Fig. 221 · Datalogic 2 of 5 Check Character Calculation

Datalogic 2 of 5 Check Character Calculation = Disable

Datalogic 2 of 5 Check Character Calculation = Enable

Page 177 of the Solis 842 user manual — Datalogic 2 of 5 Minimum Reads
Page 177 · click to enlarge
Page 177
Solis 842 — Datalogic 2 of 5 Check Character Transmission diagram (page 177)
Fig. 222 · Datalogic 2 of 5 Check Character Transmission

Datalogic 2 of 5 Check Character Transmission

This option enables/disables transmission of an optional Datalogic 2 of 5 character.

Solis 842 — Datalogic 2 of 5 Check Character Transmission diagram (page 177)
Fig. 223 · Datalogic 2 of 5 Check Character Transmission

Datalogic 2 of 5 Check Character Transmission = Don’t

Datalogic 2 of 5 Check Character Transmission = Send

Datalogic 2 of 5 Minimum Reads

This feature specifies the minimum number of consecutive times an Datalogic 2 of 5 label must be decoded before it is accepted as good read.

Solis 842 — Datalogic 2 of 5 Minimum Reads diagram (page 177)
Fig. 224 · Datalogic 2 of 5 Minimum Reads
Page 178 of the Solis 842 user manual — NOTE
Page 178 · click to enlarge
Page 178

Enter/Exit Programming Mode Datalogic 2 of 5

Datalogic 2 of 5 Decoding Level

The Datalogic 2 of 5 Decoding Level feature is set using "I 2 of 5 Decoding Level" on page 160.

NOTE

Datalogic 2 of 5 Length Control

This feature specifies either variable length decoding or fixed length decoding for the Datalogic 2 of 5 symbology.

Variable Length: For variable length decoding, a minimum and maximum length may be set.

Fixed Length: For fixed length decoding, two different lengths may be set.

Solis 842 — NOTE diagram (page 178)
Fig. 225

Datalogic 2 of 5 Length Control = Variable Length

Datalogic 2 of 5 Length Control = Fixed Length

Page 179 of the Solis 842 user manual — CANCEL
Page 179 · click to enlarge
Page 179

Datalogic 2 of 5 Enter/Exit Programming Mode

Datalogic 2 of 5 Set Length 1

This feature specifies one of the bar code lengths for Datalogic 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. The length includes the bar code’s data characters only.

The length can be set from 2 to 50 characters in increments of two. See "Set Length 1" on page 278 for more detailed programming instructions.

$CD2L1

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Datalogic 2 of 5 Length 1 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 06 = Length 1 is 6 Characters

~

Page 180 of the Solis 842 user manual — CANCEL
Page 180 · click to enlarge
Page 180

Enter/Exit Programming Mode Datalogic 2 of 5

Datalogic 2 of 5 Set Length 2

This feature specifies one of the bar code lengths for Datalogic 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the bar code’s data characters only.

The length can be set from 2 to 50 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.

$CD2L2

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Datalogic 2 of 5 Length 2 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 50 = Length 2 is 50 Characters

~

Page 181 of the Solis 842 user manual — Datalogic 2 of 5 Interdigit Ratio
Page 181 · click to enlarge
Page 181
Solis 842 — Datalogic 2 of 5 Interdigit Ratio diagram (page 181)
Fig. 226 · Datalogic 2 of 5 Interdigit Ratio

Datalogic 2 of 5 Interdigit Ratio

This feature specifies the maximum ratio between intercharacter space and module for Datalogic 2 of 5.

Solis 842 — Datalogic 2 of 5 Interdigit Ratio diagram (page 181)
Fig. 227 · Datalogic 2 of 5 Interdigit Ratio
Page 182 of the Solis 842 user manual — Datalogic 2 of 5 Interdigit Ratio
Page 182 · click to enlarge
Page 182

Enter/Exit Programming Mode Datalogic 2 of 5

Datalogic 2 of 5 Interdigit Maximum Ratio — cont.

Solis 842 — Datalogic 2 of 5 Interdigit Ratio diagram (page 182)
Fig. 228 · Datalogic 2 of 5 Interdigit Ratio
Page 183 of the Solis 842 user manual — NOTE
Page 183 · click to enlarge
Page 183
Solis 842 — Datalogic 2 of 5 Character Correlation diagram (page 183)
Fig. 229 · Datalogic 2 of 5 Character Correlation

Datalogic 2 of 5 Character Correlation

When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the reader read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.

Solis 842 — Datalogic 2 of 5 Character Correlation diagram (page 183)
Fig. 230 · Datalogic 2 of 5 Character Correlation

Datalogic 2 of 5 Stitching

This option enables/disables stitching for Datalogic 2 of 5 labels. When parts of a Datalogic 2 of 5 bar code are presented to the reader with this feature enabled, the bar code parts will be assembled by the reader’s software, and the data will be decoded if all bar code proofing requirements are met.

This feature is available only on the TD1130 model.

NOTE

Solis 842 — NOTE diagram (page 183)
Fig. 231
Page 184 of the Solis 842 user manual — Codabar Check Character Calculation
Page 184 · click to enlarge
Page 184

Enter/Exit Programming Mode Codabar

Codabar

The following options apply to the Codabar symbology.

Codabar Enable/Disable

When disabled, the reader will not read Codabar bar codes.

Solis 842 — Codabar Enable/Disable diagram (page 184)
Fig. 232 · Codabar Enable/Disable

Codabar Check Character Calculation

Enable this option to enables/disables calculation and verification of an optional Codabar check character. When disabled, any check characters in the label are treated as data characters.

Solis 842 — Codabar Check Character Calculation diagram (page 184)
Fig. 233 · Codabar Check Character Calculation
Page 185 of the Solis 842 user manual — Codabar Start/Stop Character Transmission
Page 185 · click to enlarge
Page 185
Solis 842 — Codabar Check Character Transmission diagram (page 185)
Fig. 234 · Codabar Check Character Transmission

Codabar Check Character Transmission

Enable this option to transmit the check character along with Codabar bar code data.

This feature is valid only when Codabar Check Character Calculation is enabled.

NOTE

Solis 842 — NOTE diagram (page 185)
Fig. 235

Codabar Start/Stop Character Transmission

Enable this option to enable/disable transmission of Codabar start and stop characters.

Solis 842 — Codabar Start/Stop Character Transmission diagram (page 185)
Fig. 236 · Codabar Start/Stop Character Transmission
Page 186 of the Solis 842 user manual — Codabar Start/Stop Character Set
Page 186 · click to enlarge
Page 186

Enter/Exit Programming Mode Codabar

Codabar Start/Stop Character Set

This option specifies the format of transmitted Codabar start/stop characters.

Solis 842 — Codabar Start/Stop Character Set diagram (page 186)
Fig. 237 · Codabar Start/Stop Character Set
Page 187 of the Solis 842 user manual — $CCBSM01
Page 187 · click to enlarge
Page 187

Codabar Enter/Exit Programming Mode

Codabar Start/Stop Character Match

When enabled, this option requires that start and stop characters match.

$CCBSM00

Codabar Start/Stop Character Match = Don’t Require

$CCBSM01

Codabar Start/Stop Character Match = Require Match

Match

Page 188 of the Solis 842 user manual — Codabar Quiet Zones
Page 188 · click to enlarge
Page 188

Enter/Exit Programming Mode Codabar

Codabar Quiet Zones

This feature specifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label.

Solis 842 — Codabar Quiet Zones diagram (page 188)
Fig. 238 · Codabar Quiet Zones

Codabar Quiet Zones = Quiet Zone on one side

Codabar Quiet Zones = Quiet Zones on two sides

Codabar Quiet Zones = Virtual Quiet Zones on two sides

Codabar Quiet Zones = Small Quiet Zones on two sides

Page 189 of the Solis 842 user manual — Codabar Minimum Reads
Page 189 · click to enlarge
Page 189
Solis 842 — Codabar Minimum Reads diagram (page 189)
Fig. 239 · Codabar Minimum Reads

Codabar Minimum Reads

This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good read.

Solis 842 — Codabar Minimum Reads diagram (page 189)
Fig. 240 · Codabar Minimum Reads
Page 190 of the Solis 842 user manual — Codabar Decoding Level
Page 190 · click to enlarge
Page 190

Enter/Exit Programming Mode Codabar

Codabar Decoding Level

Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.

Solis 842 — Codabar Decoding Level diagram (page 190)
Fig. 241 · Codabar Decoding Level
Page 191 of the Solis 842 user manual — $CCBLC01
Page 191 · click to enlarge
Page 191

Codabar Enter/Exit Programming Mode

Codabar Length Control

This feature specifies either variable length decoding or fixed length decoding for the Codabar symbology.

Variable Length: For variable length decoding, a minimum and maximum length may be set.

Fixed Length: For fixed length decoding, two different lengths may be set.

$CCBLC00

Codabar Length Control = Variable Length

$CCBLC01

Codabar Length Control = Fixed Length

Page 192 of the Solis 842 user manual — CANCEL
Page 192 · click to enlarge
Page 192

Enter/Exit Programming Mode Codabar

Codabar Set Length 1

This feature specifies one of the bar code lengths for Codabar Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s start, stop, check and data characters. The length must include at least one data character.

The length can be set from 3 to 50 characters. See "Set Length 1" on page 278 for more detailed programming instructions.

$CCBL1

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Codabar Length 1 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 03 = Length 1 is 3 Characters

~

Page 193 of the Solis 842 user manual — CANCEL
Page 193 · click to enlarge
Page 193

Codabar Enter/Exit Programming Mode

Codabar Set Length 2

This feature specifies one of the bar code lengths for Codabar Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the bar code’s start, stop, check and data characters. The length must include at least one data character.

The length can be set from 3 to 50 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.

$CCBL2

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Codabar Length 2 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 50 = Length 2 is 50 Characters

~

Page 194 of the Solis 842 user manual — Codabar Interdigit Ratio
Page 194 · click to enlarge
Page 194

Enter/Exit Programming Mode Codabar

Codabar Interdigit Ratio

This feature specifies the maximum ratio between an intercharacter space and module for Codabar labels.

Solis 842 — Codabar Interdigit Ratio diagram (page 194)
Fig. 242 · Codabar Interdigit Ratio
Page 195 of the Solis 842 user manual — Codabar Interdigit Ratio
Page 195 · click to enlarge
Page 195
Solis 842 — Codabar Interdigit Ratio diagram (page 195)
Fig. 243 · Codabar Interdigit Ratio

Codabar Interdigit Ratio — cont.

Solis 842 — Codabar Interdigit Ratio diagram (page 195)
Fig. 244 · Codabar Interdigit Ratio
Page 196 of the Solis 842 user manual — NOTE
Page 196 · click to enlarge
Page 196

Enter/Exit Programming Mode Codabar

Codabar Character Correlation

When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the reader read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.

Solis 842 — Codabar Character Correlation diagram (page 196)
Fig. 245 · Codabar Character Correlation

Codabar Stitching

This option enables/disables stitching for Codabar labels. When parts of a Codabar bar code are presented to the reader with this feature enabled, the bar code parts will be assembled by the reader’s software, and the data will be decoded if all bar code proofing requirements are met.

This feature is available only on the TD1130 model.

NOTE

Solis 842 — NOTE diagram (page 196)
Fig. 246
Page 197 of the Solis 842 user manual — ABC Codabar Concatenation Mode
Page 197 · click to enlarge
Page 197
Solis 842 — ABC Codabar diagram (page 197)
Fig. 247 · ABC Codabar

ABC Codabar

The following options apply to the ABC Codabar symbology.

ABC Codabar Enable/Disable

Enables/Disables ability of reader to decode ABC Codabar labels.

Solis 842 — ABC Codabar Enable/Disable diagram (page 197)
Fig. 248 · ABC Codabar Enable/Disable

ABC Codabar Concatenation Mode

Specifies the concatenation mode between Static and Dynamic.

Solis 842 — ABC Codabar Concatenation Mode diagram (page 197)
Fig. 249 · ABC Codabar Concatenation Mode
Page 198 of the Solis 842 user manual — ABC Codabar Force Concatenation
Page 198 · click to enlarge
Page 198

Enter/Exit Programming Mode ABC Codabar

ABC Codabar Dynamic Concatenation Timeout

This parameter specifies the timeout in 10-millisecond ticks used by the ABC Codabar Dynamic Concatenation Mode. The timeout can be set within a range of 05 to 255 in 10ms increments. A setting of zero specifies no delay.

Solis 842 — ABC Codabar Dynamic Concatenation Timeout diagram (page 198)
Fig. 250 · ABC Codabar Dynamic Concatenation Timeout

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad representing your desired character(s). End by scanning the ENTER/EXIT bar code again.

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

ABC Codabar Force Concatenation

Forces labels starting or ending with D to be concatenated.

Solis 842 — ABC Codabar Force Concatenation diagram (page 198)
Fig. 251 · ABC Codabar Force Concatenation
Page 199 of the Solis 842 user manual — $CC1EN01
Page 199 · click to enlarge
Page 199

Code 11 Enter/Exit Programming Mode

Code 11

The following options apply to the Code 11 symbology.

Code 11 Enable/Disable

When disabled, the reader will not read Code 11 bar codes.

$CC1EN00

Code 11 = Disable

$CC1EN01

Code 11 = Enable

Page 200 of the Solis 842 user manual — Code 11 Check Character Transmission
Page 200 · click to enlarge
Page 200

Enter/Exit Programming Mode Code 11

Code 11 Check Character Calculation

This option enables/disables calculation and verification of optional Code 11 check character.

Solis 842 — Code 11 Check Character Calculation diagram (page 200)
Fig. 252 · Code 11 Check Character Calculation

Code 11 Check Character Calculation = Check C and K

Code 11 Check Character Transmission

This feature enables/disables transmission of an optional Code 11 check character.

Solis 842 — Code 11 Check Character Transmission diagram (page 200)
Fig. 253 · Code 11 Check Character Transmission
Page 201 of the Solis 842 user manual — Code 11 Minimum Reads
Page 201 · click to enlarge
Page 201
Solis 842 — Code 11 Minimum Reads diagram (page 201)
Fig. 254 · Code 11 Minimum Reads

Code 11 Minimum Reads

This feature specifies the minimum number of consecutive times a Code 11 label must be decoded before it is accepted as good read.

Solis 842 — Code 11 Minimum Reads diagram (page 201)
Fig. 255 · Code 11 Minimum Reads
Page 202 of the Solis 842 user manual — Code 11 Set Length 1
Page 202 · click to enlarge
Page 202

Enter/Exit Programming Mode Code 11

Code 11 Length Control

This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology.

Variable Length: For variable length decoding, a minimum and maximum length may be set.

Fixed Length: For fixed length decoding, two different lengths may be set.

Solis 842 — Code 11 Length Control diagram (page 202)
Fig. 256 · Code 11 Length Control

Code 11 Set Length 1

This feature specifies one of the bar code lengths for Code 11 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s check and data characters.

The length can be set from 2 to 50 characters. See "Set Length 1" on page 278 for more detailed programming instructions.

Solis 842 — Code 11 Set Length 1 diagram (page 202)
Fig. 257 · Code 11 Set Length 1

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

Page 203 of the Solis 842 user manual — CANCEL
Page 203 · click to enlarge
Page 203

Code 11 Enter/Exit Programming Mode

Code 11 Set Length 2

This feature specifies one of the bar code lengths for Code 11 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check and data characters.

The length can be set from 2 to 50 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.

$CC1L2

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Code 11 Length 2 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 50 = Length 2 is 50 Characters

~

Page 204 of the Solis 842 user manual — Code 11 Interdigit Ratio
Page 204 · click to enlarge
Page 204

Enter/Exit Programming Mode Code 11

Code 11 Interdigit Ratio

This feature specifies the ratio between an intercharacter space and module for Code 11 labels.

Solis 842 — Code 11 Interdigit Ratio diagram (page 204)
Fig. 258 · Code 11 Interdigit Ratio
Page 205 of the Solis 842 user manual — Code 11 Interdigit Ratio
Page 205 · click to enlarge
Page 205
Solis 842 — Code 11 Interdigit Ratio diagram (page 205)
Fig. 259 · Code 11 Interdigit Ratio

Code 11 Interdigit Ratio — cont.

Solis 842 — Code 11 Interdigit Ratio diagram (page 205)
Fig. 260 · Code 11 Interdigit Ratio
Page 206 of the Solis 842 user manual — Code 11 Decoding Level
Page 206 · click to enlarge
Page 206

Enter/Exit Programming Mode Code 11

Code 11 Decoding Level

Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.

Solis 842 — Code 11 Decoding Level diagram (page 206)
Fig. 261 · Code 11 Decoding Level
Page 207 of the Solis 842 user manual — NOTE
Page 207 · click to enlarge
Page 207
Solis 842 — Code 11 Character Correlation diagram (page 207)
Fig. 262 · Code 11 Character Correlation

Code 11 Character Correlation

When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the reader read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.

Solis 842 — Code 11 Character Correlation diagram (page 207)
Fig. 263 · Code 11 Character Correlation

Code 11 Stitching

This option enables/disables stitching for Code 11 labels. When parts of a Code 11 bar code are presented to the reader with this feature enabled, the bar code parts will be assembled by the reader’s software, and the data will be decoded if all bar code proofing requirements are met.

This feature is available only on the TD1130 model.

NOTE

Solis 842 — NOTE diagram (page 207)
Fig. 264
Page 208 of the Solis 842 user manual — Standard 2 of 5 Check Character Calculation
Page 208 · click to enlarge
Page 208

Enter/Exit Programming Mode Standard 2 of 5

Standard 2 of 5

The following options apply to the Standard 2 of 5 symbology.

Standard 2 of 5 Enable/Disable

When disabled, the reader will not read Standard 2 of 5 bar codes.

Solis 842 — Standard 2 of 5 Enable/Disable diagram (page 208)
Fig. 265 · Standard 2 of 5 Enable/Disable

Standard 2 of 5 Check Character Calculation

This option enables/disables calculation and verification of an optional Standard 2 of 5 check character.

Solis 842 — Standard 2 of 5 Check Character Calculation diagram (page 208)
Fig. 266 · Standard 2 of 5 Check Character Calculation

Standard 2 of 5 Check Character Calculation = Disable

Standard 2 of 5 Check Character Calculation = Enable

Page 209 of the Solis 842 user manual — Standard 2 of 5 Minimum Reads
Page 209 · click to enlarge
Page 209
Solis 842 — Standard 2 of 5 Check Character Transmission diagram (page 209)
Fig. 267 · Standard 2 of 5 Check Character Transmission

Standard 2 of 5 Check Character Transmission

This feature enables/disables transmission of an optional Standard 2 of 5 check character.

Solis 842 — Standard 2 of 5 Check Character Transmission diagram (page 209)
Fig. 268 · Standard 2 of 5 Check Character Transmission

Standard 2 of 5 Check Character Transmission = Don’t

Standard 2 of 5 Check Character Transmission = Send

Standard 2 of 5 Minimum Reads

This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as good read.

Solis 842 — Standard 2 of 5 Minimum Reads diagram (page 209)
Fig. 269 · Standard 2 of 5 Minimum Reads
Page 210 of the Solis 842 user manual — NOTE
Page 210 · click to enlarge
Page 210

Enter/Exit Programming Mode Standard 2 of 5

Standard 2 of 5 Decoding Level

The Standard 2 of 5 Decoding Level feature is set using "I 2 of 5 Decoding Level" on page 160.

NOTE

Standard 2 of 5 Length Control

This feature specifies either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology.

Variable Length: For variable length decoding, a minimum and maximum length may be set.

Fixed Length: For fixed length decoding, two different lengths may be set.

Solis 842 — NOTE diagram (page 210)
Fig. 270

Standard 2 of 5 Length Control = Variable Length

Standard 2 of 5 Length Control = Fixed Length

Page 211 of the Solis 842 user manual — CANCEL
Page 211 · click to enlarge
Page 211

Standard 2 of 5 Enter/Exit Programming Mode

Standard 2 of 5 Set Length 1

This feature specifies one of the bar code lengths for Standard 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s check and data characters.

The length can be set from 1 to 50 characters. See "Set Length 1" on page 278 for more detailed programming instructions.

$CS2L1

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Standard 2 of 5 Length 1 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 08 = Length 1 is 8 Characters

~

Page 212 of the Solis 842 user manual — CANCEL
Page 212 · click to enlarge
Page 212

Enter/Exit Programming Mode Standard 2 of 5

Standard 2 of 5 Set Length 2

This feature specifies one of the bar code lengths for Standard 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check and data characters.

The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.

$CS2L2

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Standard 2 of 5 Length 2 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 50 = Length 2 is 50 Characters

~

Page 213 of the Solis 842 user manual — NOTE
Page 213 · click to enlarge
Page 213
Solis 842 — Standard 2 of 5 Character Correlation diagram (page 213)
Fig. 271 · Standard 2 of 5 Character Correlation

Standard 2 of 5 Character Correlation

When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the reader read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.

Solis 842 — Standard 2 of 5 Character Correlation diagram (page 213)
Fig. 272 · Standard 2 of 5 Character Correlation

Standard 2 of 5 Stitching

This option enables/disables stitching for Standard 2 of 5 labels. When parts of a Standard 2 of 5 bar code are presented to the reader with this feature enabled, the bar code parts will be assembled by the reader’s software, and the data will be decoded if all bar code proofing requirements are met.

This feature is available only on the TD1130 model.

NOTE

Solis 842 — NOTE diagram (page 213)
Fig. 273
Page 214 of the Solis 842 user manual — Industrial 2 of 5 Check Character Calculation
Page 214 · click to enlarge
Page 214

Enter/Exit Programming Mode Industrial 2 of 5

Industrial 2 of 5

The following options apply to the Industrial 2 of 5 symbology.

Industrial 2 of 5 Enable/Disable

Enables/Disables ability of reader to decode Industrial 2 of 5 labels.

Solis 842 — Industrial 2 of 5 Enable/Disable diagram (page 214)
Fig. 274 · Industrial 2 of 5 Enable/Disable

Industrial 2 of 5 Check Character Calculation

Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.

Solis 842 — Industrial 2 of 5 Check Character Calculation diagram (page 214)
Fig. 275 · Industrial 2 of 5 Check Character Calculation

Industrial 2 of 5 Check Character Calculation = Disable

Industrial 2 of 5 Check Character Calculation = Enable

Page 215 of the Solis 842 user manual — Industrial 2 of 5 Length Control
Page 215 · click to enlarge
Page 215
Solis 842 — Industrial 2 of 5 Check Character Transmission diagram (page 215)
Fig. 276 · Industrial 2 of 5 Check Character Transmission

Industrial 2 of 5 Check Character Transmission

Enables/disables transmission of an Industrial 2 of 5 check character.

Solis 842 — Industrial 2 of 5 Check Character Transmission diagram (page 215)
Fig. 277 · Industrial 2 of 5 Check Character Transmission

Industrial 2 of 5 Check Character Transmission = Disable

Industrial 2 of 5 Check Character Transmission = Enable

Industrial 2 of 5 Length Control

This feature specifies either variable length decoding or fixed length decoding for the Industrial 2 of 5 symbology.

Variable Length: For variable length decoding, a minimum and maximum length may be set.

Fixed Length: For fixed length decoding, two different lengths may be set.

Solis 842 — Industrial 2 of 5 Length Control diagram (page 215)
Fig. 278 · Industrial 2 of 5 Length Control

Industrial 2 of 5 Length Control = Variable Length

Page 216 of the Solis 842 user manual — CANCEL
Page 216 · click to enlarge
Page 216

Enter/Exit Programming Mode Industrial 2 of 5

Industrial 2 of 5 Set Length 1

This feature specifies one of the bar code lengths for Industrial 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.

The length can be set from 1 to 50 characters. See "Set Length 1" on page 278 for more detailed programming instructions.

$CU2L1

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Industrial 2 of 5 Set Length 1 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 01 = Length 1 is 1 Character

~

Page 217 of the Solis 842 user manual — CANCEL
Page 217 · click to enlarge
Page 217

Industrial 2 of 5 Enter/Exit Programming Mode

Industrial 2 of 5 Set Length 2

This feature specifies one of the bar code lengths for Industrial 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.

The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.

$CU2L2

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Industrial 2 of 5 Length 2 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 50 = Length 2 is 50 Characters

~

Page 218 of the Solis 842 user manual — Industrial 2 of 5 Minimum Reads
Page 218 · click to enlarge
Page 218

Enter/Exit Programming Mode Industrial 2 of 5

Industrial 2 of 5 Minimum Reads

This feature specifies the minimum number of consecutive times an Industrial 2 of 5 label must be decoded before it is accepted as good read.

Solis 842 — Industrial 2 of 5 Minimum Reads diagram (page 218)
Fig. 279 · Industrial 2 of 5 Minimum Reads
Page 219 of the Solis 842 user manual — Industrial 2 of 5 Character Correlation
Page 219 · click to enlarge
Page 219
Solis 842 — Industrial 2 of 5 Stitching diagram (page 219)
Fig. 280 · Industrial 2 of 5 Stitching

Industrial 2 of 5 Stitching

Enables/disables fixed length stitching for Industrial 2 of 5.

This feature is available only on the TD1130 model.

NOTE

Solis 842 — NOTE diagram (page 219)
Fig. 281

Industrial 2 of 5 Character Correlation

Enable/disables character correlation for Industrial 2 of 5.

Solis 842 — Industrial 2 of 5 Character Correlation diagram (page 219)
Fig. 282 · Industrial 2 of 5 Character Correlation
Page 220 of the Solis 842 user manual — IATA Check Character Transmission
Page 220 · click to enlarge
Page 220

Enter/Exit Programming Mode IATA

IATA

The following options apply to the IATA symbology.

IATA Enable/Disable

Enables/Disables the ability of the reader to decode IATA labels.

Solis 842 — IATA Enable/Disable diagram (page 220)
Fig. 283 · IATA Enable/Disable

IATA Check Character Transmission

Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.

Solis 842 — IATA Check Character Transmission diagram (page 220)
Fig. 284 · IATA Check Character Transmission
Page 221 of the Solis 842 user manual — NOTE
Page 221 · click to enlarge
Page 221
Solis 842 — ISBT 128 diagram (page 221)
Fig. 285

ISBT 128

The following options apply to the ISBT 128 symbology.

ISBT 128 Concatenation

Enables/disables ISBT128 concatenation of 2 labels.

Solis 842 — ISBT 128 Concatenation diagram (page 221)
Fig. 286 · ISBT 128 Concatenation

ISBT 128 Concatenation Mode

Specifies the concatenation mode between Static and Dynamic.

This option is only valid when ISBT 128 Concatenation is enabled (see page 211).

NOTE

Solis 842 — NOTE diagram (page 221)
Fig. 287
Page 222 of the Solis 842 user manual — ISBT 128 Dynamic Concatenation Timeout
Page 222 · click to enlarge
Page 222

Enter/Exit Programming Mode ISBT 128

ISBT 128 Dynamic Concatenation Timeout

Specifies the timeout used by the ISBT 128 Dynamic Concatenation Mode.

Solis 842 — ISBT 128 Dynamic Concatenation Timeout diagram (page 222)
Fig. 288 · ISBT 128 Dynamic Concatenation Timeout
Page 223 of the Solis 842 user manual — NOTE
Page 223 · click to enlarge
Page 223
Solis 842 — ISBT 128 Force Concatenation diagram (page 223)
Fig. 289 · ISBT 128 Force Concatenation

ISBT 128 Force Concatenation

When enabled, this feature forces all ISBT 128 labels to be concatenated.

This option is only valid when ISBT 128 Concatenation is enabled. (see page 211).

NOTE

Solis 842 — NOTE diagram (page 223)
Fig. 290

ISBT 128 Advanced Concatenation Options

Use the Datalogic Aladdin configuration application or Contact Customer Support to set up pairs of label types for concatenation.

NOTE

Page 224 of the Solis 842 user manual — MSI Check Character Calculation
Page 224 · click to enlarge
Page 224

Enter/Exit Programming Mode MSI

MSI

The following options apply to the MSI symbology.

MSI Enable/Disable

Enables/Disables ability of reader to decode MSI labels.

Solis 842 — MSI Enable/Disable diagram (page 224)
Fig. 291 · MSI Enable/Disable

MSI Check Character Calculation

Enables/Disables calculation and verification of an optional MSI check character.

Solis 842 — MSI Check Character Calculation diagram (page 224)
Fig. 292 · MSI Check Character Calculation
Page 225 of the Solis 842 user manual — MSI Length Control
Page 225 · click to enlarge
Page 225
Solis 842 — MSI Check Character Transmission diagram (page 225)
Fig. 293 · MSI Check Character Transmission

MSI Check Character Transmission

Enables/disables transmission of an MSI check character.

Solis 842 — MSI Check Character Transmission diagram (page 225)
Fig. 294 · MSI Check Character Transmission

MSI Length Control

This feature specifies either variable length decoding or fixed length decoding for the MSI symbology.

Variable Length: For variable length decoding, a minimum and maximum length may be set.

Fixed Length: For fixed length decoding, two different lengths may be set.

Solis 842 — MSI Length Control diagram (page 225)
Fig. 295 · MSI Length Control
Page 226 of the Solis 842 user manual — CANCEL
Page 226 · click to enlarge
Page 226

Enter/Exit Programming Mode MSI

MSI Set Length 1

This feature specifies one of the bar code lengths for MSI Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.

The length can be set from 01 to 50 characters. See "Set Length 1" on page 278 for more detailed programming instructions.

$CMSL1

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select MSI Set Length 1 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 01 = Length 1 is 1 Character

~

Page 227 of the Solis 842 user manual — CANCEL
Page 227 · click to enlarge
Page 227

MSI Enter/Exit Programming Mode

MSI Set Length 2

This feature specifies one of the bar code lengths for MSI Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.

The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.

$CMSL2

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select MSI Length 2 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 50 = Length 2 is 50 Characters

~

Page 228 of the Solis 842 user manual — MSI Minimum Reads
Page 228 · click to enlarge
Page 228

Enter/Exit Programming Mode MSI

MSI Minimum Reads

This feature specifies the minimum number of consecutive times an MSI label must be decoded before it is accepted as good read.

Solis 842 — MSI Minimum Reads diagram (page 228)
Fig. 296 · MSI Minimum Reads
Page 229 of the Solis 842 user manual — MSI Decoding Level
Page 229 · click to enlarge
Page 229
Solis 842 — MSI Decoding Level diagram (page 229)
Fig. 297 · MSI Decoding Level

MSI Decoding Level

Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.

Solis 842 — MSI Decoding Level diagram (page 229)
Fig. 298 · MSI Decoding Level
Page 230 of the Solis 842 user manual — Code 93 Check Character Calculation
Page 230 · click to enlarge
Page 230

Enter/Exit Programming Mode Code 93

Code 93

The following options apply to the Code 93 symbology.

Code 93 Enable/Disable

Enables/Disables ability of reader to decode Code 93 labels.

Solis 842 — Code 93 Enable/Disable diagram (page 230)
Fig. 299 · Code 93 Enable/Disable

Code 93 Check Character Calculation

Enables/disables calculation and verification of an optional Code 93 check character.

Solis 842 — Code 93 Check Character Calculation diagram (page 230)
Fig. 300 · Code 93 Check Character Calculation

Code 93 Check Character Calculation = Enable Check C

Code 93 Check Character Calculation = Enable Check K

Page 231 of the Solis 842 user manual — Code 93 Length Control
Page 231 · click to enlarge
Page 231
Solis 842 — Code 93 Check Character Transmission diagram (page 231)
Fig. 301 · Code 93 Check Character Transmission

Code 93 Check Character Transmission

Enables/disables transmission of an optional Code 93 check character.

Solis 842 — Code 93 Check Character Transmission diagram (page 231)
Fig. 302 · Code 93 Check Character Transmission

Code 93 Length Control

This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology.

Variable Length: For variable length decoding, a minimum and maximum length may be set.

Fixed Length: For fixed length decoding, two different lengths may be set.

Solis 842 — Code 93 Length Control diagram (page 231)
Fig. 303 · Code 93 Length Control
Page 232 of the Solis 842 user manual — CANCEL
Page 232 · click to enlarge
Page 232

Enter/Exit Programming Mode Code 93

Code 93 Set Length 1

This feature specifies one of the bar code lengths for Code 93 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.

The length can be set from 01 to 50 characters. See "Set Length 1" on page 278 for more detailed programming instructions.

$CC9L1

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Code 93 Set Length 1 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 01 = Length 1 is 1 Character

~

Page 233 of the Solis 842 user manual — CANCEL
Page 233 · click to enlarge
Page 233

Code 93 Enter/Exit Programming Mode

Code 93 Set Length 2

This feature specifies one of the bar code lengths for Code 93 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.

The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.

$CC9L2

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Code 93 Length 2 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 50 = Length 2 is 50 Characters

~

Page 234 of the Solis 842 user manual — Code 93 Minimum Reads
Page 234 · click to enlarge
Page 234

Enter/Exit Programming Mode Code 93

Code 93 Minimum Reads

This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read.

Solis 842 — Code 93 Minimum Reads diagram (page 234)
Fig. 304 · Code 93 Minimum Reads
Page 235 of the Solis 842 user manual — Code 93 Decoding Level
Page 235 · click to enlarge
Page 235
Solis 842 — Code 93 Decoding Level diagram (page 235)
Fig. 305 · Code 93 Decoding Level

Code 93 Decoding Level

Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.

Solis 842 — Code 93 Decoding Level diagram (page 235)
Fig. 306 · Code 93 Decoding Level
Page 236 of the Solis 842 user manual — NOTE
Page 236 · click to enlarge
Page 236

Enter/Exit Programming Mode Code 93

Code 93 Quiet Zones

Enables/disables fixed length stitching for Code 93.

This feature is available only on the TD1130 model.

NOTE

Solis 842 — NOTE diagram (page 236)
Fig. 307

Code 93 Quiet Zones = Quiet Zone on one side

Code 93 Quiet Zones = Quiet Zones on two sides

Code 93 Quiet Zones = Virtual Quiet Zones on two sides

Page 237 of the Solis 842 user manual — Code 93 Character Correlation
Page 237 · click to enlarge
Page 237
Solis 842 — Code 93 Stitching diagram (page 237)
Fig. 308 · Code 93 Stitching

Code 93 Stitching

Disable/enable fixed or variable length stitching for Code 93.

This feature is available only on the TD1130 model.

NOTE

Solis 842 — NOTE diagram (page 237)
Fig. 309

Code 93 Character Correlation

Enables/disables Character Correlation for Code 93.

Solis 842 — Code 93 Character Correlation diagram (page 237)
Fig. 310 · Code 93 Character Correlation
Page 238 of the Solis 842 user manual — Codablock F EAN Enable/Disable
Page 238 · click to enlarge
Page 238

Enter/Exit Programming Mode Codablock F

Codablock F

The following options apply to the Codablock F symbology.

Codablock F Enable/Disable

Enables/Disables the ability of the reader to decode Codablock F labels.

Solis 842 — Codablock F Enable/Disable diagram (page 238)
Fig. 311 · Codablock F Enable/Disable

Codablock F EAN Enable/Disable

Enables/Disables the Codablock F EAN subtype (code with FNC1 in the first position).

Solis 842 — Codablock F EAN Enable/Disable diagram (page 238)
Fig. 312 · Codablock F EAN Enable/Disable
Page 239 of the Solis 842 user manual — Codablock F Length Control
Page 239 · click to enlarge
Page 239
Solis 842 — Codablock F AIM Check diagram (page 239)
Fig. 313 · Codablock F AIM Check

Codablock F AIM Check

Specifies if Check Digit calculation algorithm is AIM compliant or not.

Solis 842 — Codablock F AIM Check diagram (page 239)
Fig. 314 · Codablock F AIM Check

Codablock F Length Control

This feature specifies either variable length decoding or fixed length decoding for the Codablock F symbology.

Variable Length: For variable length decoding, a minimum and maximum length may be set.

Fixed Length: For fixed length decoding, two different lengths may be set.

Solis 842 — Codablock F Length Control diagram (page 239)
Fig. 315 · Codablock F Length Control
Page 240 of the Solis 842 user manual — CANCEL
Page 240 · click to enlarge
Page 240

Enter/Exit Programming Mode Codablock F

Codablock F Set Length 1

This feature specifies one of the bar code lengths for Codablock F Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.

The length can be set from 003 to 255 characters. See "Set Length 1" on page 278 for more detailed programming instructions.

$CCFL1

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Codablock F Length 1 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 003 = Length 1 is 3 Characters

~

Page 241 of the Solis 842 user manual — CANCEL
Page 241 · click to enlarge
Page 241

Codablock F Enter/Exit Programming Mode

Codablock F Set Length 2

This feature specifies one of the bar code lengths for Codablock F Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.

The length can be set from 3 to 255 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.

$CCFL2

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select Codablock F Length 2 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 100 = Length 2 is 100 Characters

~

Page 242 of the Solis 842 user manual — Code 4 Check Character Transmission
Page 242 · click to enlarge
Page 242

Enter/Exit Programming Mode Code 4

Code 4

The following options apply to the Code 4 symbology.

Code 4 Enable/Disable

Enables/Disables ability of reader to decode Code 4 labels.

Solis 842 — Code 4 Enable/Disable diagram (page 242)
Fig. 316 · Code 4 Enable/Disable

Code 4 Check Character Transmission

This feature enables/disables transmission of an optional Code 4 check character.

Solis 842 — Code 4 Check Character Transmission diagram (page 242)
Fig. 317 · Code 4 Check Character Transmission
Page 243 of the Solis 842 user manual — Code 5 Enable/Disable
Page 243 · click to enlarge
Page 243
Solis 842 — Code 4 Hex to Decimal Conversion diagram (page 243)
Fig. 318 · Code 4 Hex to Decimal Conversion

Code 4 Hex to Decimal Conversion

This feature enables/disables the conversion of hexadecimal label data to decimal label data.

Solis 842 — Code 4 Hex to Decimal Conversion diagram (page 243)
Fig. 319 · Code 4 Hex to Decimal Conversion

Code 5

The following options apply to the Code 5 symbology.

Code 5 Enable/Disable

Enables/Disables ability of reader to decode Code 5 labels.

Solis 842 — Code 5 Enable/Disable diagram (page 243)
Fig. 320 · Code 5 Enable/Disable
Page 244 of the Solis 842 user manual — Code 5 Hex to Decimal Conversion
Page 244 · click to enlarge
Page 244

Enter/Exit Programming Mode Code 5

Code 5 Check Character Transmission

This feature enables/disables transmission of an optional Code 5 check character.

Solis 842 — Code 5 Check Character Transmission diagram (page 244)
Fig. 321 · Code 5 Check Character Transmission

Code 5 Hex to Decimal Conversion

This feature enables/disables the conversion of hexadecimal label data to decimal label data.

Solis 842 — Code 5 Hex to Decimal Conversion diagram (page 244)
Fig. 322 · Code 5 Hex to Decimal Conversion
Page 245 of the Solis 842 user manual — NOTE
Page 245 · click to enlarge
Page 245
Solis 842 — Code 4 and Code 5 Common Configuration Items diagram (page 245)
Fig. 323 · Code 4 and Code 5 Common Configuration Items

Code 4 and Code 5 Common Configuration Items Enter/Exit Programming Mode

Code 4 and Code 5 Common Configuration Items

The following options apply to both Code 4 and Code 5 symbologies.

Code 4 and 5 Decoding Level

Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.

This configuration item applies to Code 4 and Code 5.

NOTE

Solis 842 — NOTE diagram (page 245)
Fig. 324

Code 4 and Code 5 Decoding Level = 1

Code 4 and Code 5 Decoding Level = 2

Code 4 and Code 5 Decoding Level = 3

Code 4 and Code 5 Decoding Level = 4

Code 4 and Code 5 Decoding Level = 5

Page 246 of the Solis 842 user manual — Code 4 and Code 5 Minimum Reads
Page 246 · click to enlarge
Page 246

Enter/Exit Programming Mode Code 4 and Code 5 Common Configuration Items

Code 4 and Code 5 Minimum Reads

This feature specifies the minimum number of consecutive times a Code 4 or Code 5 label must be decoded before it is accepted as good read.

Solis 842 — Code 4 and Code 5 Minimum Reads diagram (page 246)
Fig. 325 · Code 4 and Code 5 Minimum Reads

Code 4 or Code 5 Minimum Reads = 1

Code 4 or Code 5 Minimum Reads = 2

Code 4 or Code 5 Minimum Reads = 3

Code 4 or Code 5 Minimum Reads = 4

Page 247 of the Solis 842 user manual — BC412 Enable/Disable
Page 247 · click to enlarge
Page 247
Solis 842 — Follett 2 of 5 diagram (page 247)
Fig. 326 · Follett 2 of 5

Follett 2 of 5

The following options apply to the Follett 2 of 5 symbology.

Follett 2 of 5 Enable/Disable

Enables/Disables ability of reader to decode Follett 2 of 5 labels.

Solis 842 — Follett 2 of 5 Enable/Disable diagram (page 247)
Fig. 327 · Follett 2 of 5 Enable/Disable

BC412

The following options apply to the BC412 symbology.

BC412 Enable/Disable

Enables/Disables ability of reader to decode BC412 labels.

Solis 842 — BC412 Enable/Disable diagram (page 247)
Fig. 328 · BC412 Enable/Disable
Page 248 of the Solis 842 user manual — BC412 Minimum Reads
Page 248 · click to enlarge
Page 248

Enter/Exit Programming Mode BC412

BC412 Check Character Calculation

Enable this option to enable/disable calculation and verification of an optional BC412 check character. When disabled, any check character in the label is treated as a data character.

Solis 842 — BC412 Check Character Calculation diagram (page 248)
Fig. 329 · BC412 Check Character Calculation

BC412 Minimum Reads

This feature specifies the minimum number of consecutive times a BC412 label must be decoded before it is accepted as good read.

Solis 842 — BC412 Minimum Reads diagram (page 248)
Fig. 330 · BC412 Minimum Reads
Page 249 of the Solis 842 user manual — BC412 Decoding Level
Page 249 · click to enlarge
Page 249
Solis 842 — BC412 Decoding Level diagram (page 249)
Fig. 331 · BC412 Decoding Level

BC412 Decoding Level

Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more detailed programming instructions.

Solis 842 — BC412 Decoding Level diagram (page 249)
Fig. 332 · BC412 Decoding Level
Page 250 of the Solis 842 user manual — BC412 Set Length 1
Page 250 · click to enlarge
Page 250

Enter/Exit Programming Mode BC412

BC412 Length Control

This feature specifies either variable length decoding or fixed length decoding for the BC412 symbology.

Variable Length: For variable length decoding, a minimum and maximum length may be set.

Fixed Length: For fixed length decoding, two different lengths may be set.

Solis 842 — BC412 Length Control diagram (page 250)
Fig. 333 · BC412 Length Control

BC412 Set Length 1

This feature specifies one of the bar code lengths for BC412 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.

The length can be set from 0 to 50 characters. See "Set Length 1" on page 278 for more detailed programming instructions.

Solis 842 — BC412 Set Length 1 diagram (page 250)
Fig. 334 · BC412 Set Length 1

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

Page 251 of the Solis 842 user manual — CANCEL
Page 251 · click to enlarge
Page 251

BC412 Enter/Exit Programming Mode

BC412 Set Length 2

This feature specifies one of the bar code lengths for BC412 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.

The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length (only one fixed length). See "Set Length 2" on page 280 for more detailed programming instructions.

$CBCL2

To configure this feature, scan the ENTER/EXIT bar code above, then the bar code at left followed by digits from the Alphanumeric characters in Appendix D, Keypad repre- senting your desired character(s). End by scanning the ENTER/ EXIT bar code again.

Select BC412 Length 2 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the begin- ning.

CANCEL

DEFAULT 50 = Length 2 is 50 Characters

~

Page 252 of the Solis 842 user manual — Plessey Enable/Disable
Page 252 · click to enlarge
Page 252

Enter/Exit Programming Mode Plessey

Plessey

The following options apply to the Plessey symbology.

Plessey Enable/Disable

Enables/Disables ability of reader to decode Plessey labels.

Solis 842 — Plessey Enable/Disable diagram (page 252)
Fig. 335 · Plessey Enable/Disable
Page 253 of the Solis 842 user manual — Plessey Check Character Calculation
Page 253 · click to enlarge
Page 253
Solis 842 — Plessey Check Character Calculation diagram (page 253)
Fig. 336 · Plessey Check Character Calculation

Plessey Check Character Calculation

Enables/Disables calculation and verification of an optional Plessey check character.

Solis 842 — Plessey Check Character Calculation diagram (page 253)
Fig. 337 · Plessey Check Character Calculation

Plessey Check Character Calculation = Enable Plessey std. check char. verification

Plessey Check Character Calculation = Enable Plessey std. and Anker check char verification

Page 254 of the Solis 842 user manual — Plessey Length Control
Page 254 · click to enlarge
Page 254

Enter/Exit Programming Mode Plessey

Plessey Check Character Transmission

Enables/disables transmission of an MSI check character.

Solis 842 — Plessey Check Character Transmission diagram (page 254)
Fig. 338 · Plessey Check Character Transmission

Plessey Length Control

This feature specifies either variable length decoding or fixed length decoding for the Plessey symbology.

Variable Length. For variable length decoding, a minimum and maximum length may be set.

Fixed Length. For fixed length decoding, two different lengths may be set.

Solis 842 — Plessey Length Control diagram (page 254)
Fig. 339 · Plessey Length Control
Page 255 of the Solis 842 user manual — CANCEL
Page 255 · click to enlarge
Page 255

Plessey Enter/Exit Programming Mode

Plessey Set Length 1

This feature specifies one of the barcode lengths for Plessey Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50 characters.

Table 2 provides some examples for setting Length 1. See "Set Length 1" on page 278 for detailed instructions on setting this feature.

Table 2. Plessey Length 1 Setting Examples

STEP ACTION EXAMPLES

1 Desired Setting 01 Character 07 Characters 15 Characters 50 Characters

2 Scan ENTER/EXIT PROGRAMMING MODE

3 Scan SELECT Plessey LENGTH 1 SETTING

4 Scan Two Characters From

Appendix D, Keypad ‘0’ and ‘1’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’

5 Scan ENTER/EXIT PROGRAMMING MODE

Select Plessey Set Length 1 Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

CANCEL

DEFAULT 01 = Length 1 is 1 Character

Page 256 of the Solis 842 user manual — CANCEL
Page 256 · click to enlarge
Page 256

Enter/Exit Programming Mode Plessey

Plessey Set Length 2

This feature specifies one of the barcode lengths for Plessey Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.

The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).

Table 3 provides examples for setting Length 2. See "Set Length 2" on page 280 for detailed instructions on setting this feature.

Table 3. Plessey Length 2 Setting Examples

STEP ACTION EXAMPLES

1 Desired Setting 00 (Ignore This Length) 07 Characters 15 Characters 50 Characters

2 Scan ENTER/EXIT PROGRAMMING MODE

3 Scan SELECT PLESSEY LENGTH 2 SETTING

4 Scan Two Characters From

Appendix D, Keypad ‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’

5 Scan ENTER/EXIT PROGRAMMING MODE

Select Plessey Length 2 Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

CANCEL

DEFAULT 50 = Length 2 is 50 Characters

Page 257 of the Solis 842 user manual — Plessey Minimum Reads
Page 257 · click to enlarge
Page 257
Solis 842 — Plessey Minimum Reads diagram (page 257)
Fig. 340 · Plessey Minimum Reads

Plessey Minimum Reads

This feature specifies the minimum number of consecutive times a Plessey label must be decoded before it is accepted as good read.

Solis 842 — Plessey Minimum Reads diagram (page 257)
Fig. 341 · Plessey Minimum Reads
Page 258 of the Solis 842 user manual — Plessey Decoding Level
Page 258 · click to enlarge
Page 258

Enter/Exit Programming Mode Plessey

Plessey Decoding Level

Specifies the decoding level for Plessey. Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See "Decoding Levels" on page 278 for more information on this feature.

Solis 842 — Plessey Decoding Level diagram (page 258)
Fig. 342 · Plessey Decoding Level
Page 259 of the Solis 842 user manual — Plessey Character Correlation
Page 259 · click to enlarge
Page 259
Solis 842 — Plessey Stitching diagram (page 259)
Fig. 343 · Plessey Stitching

Plessey Stitching

Enables/disables fixed length stitching for Plessey.

Solis 842 — Plessey Stitching diagram (page 259)
Fig. 344 · Plessey Stitching

Plessey Character Correlation

Enables/disables Character Correlation for Plessey.

Solis 842 — Plessey Character Correlation diagram (page 259)
Fig. 345 · Plessey Character Correlation
Page 260 of the Solis 842 user manual — NOTES
Page 260 · click to enlarge
Page 260

NOTES

Page 261 of the Solis 842 user manual — Table of contents
Page 261 · click to enlarge
Page 261

Table of contents

Introductionp.11About the Touch TD1100p.11About this Manualp.11Overviewp.11Conventionsp.12Technical Supportp.12Datalogic Website Supportp.12Reseller Technical Supportp.12Telephone Technical Supportp.13Setupp.15Unpackingp.15Setting Up the Readerp.15Install the Interface Cablep.15Connect Host Interfacep.17Holder/Hands-Free Standp.18Interface Selectionp.19Configuring the Interfacep.19Customizing Configuration Settingsp.22Using the Programming Bar Codesp.22Interface Settingsp.23Configuring Other Featuresp.23Software Version Transmissionp.23Configuration Using Bar Codesp.25Configuration Parametersp.25Host Commands — Obey/Ignorep.27USB Suspend Modep.28RS-232 Only Interfacep.29RS-232 Standard Factory Settingsp.29Baud Ratep.29Data Bitsp.31Stop Bitsp.31Parityp.32Handshaking Controlp.33RS-232/USB-Com Interfacesp.35Standard Factory Settingsp.35Intercharacter Delayp.35Beep On ASCII BELp.36Beep On Not on Filep.36ACK NAK Optionsp.37ACK Characterp.38NAK Characterp.38ACK NAK Timeout Valuep.39ACK NAK Retry Countp.40ACK NAK Error Handlingp.41Indicate Transmission Failurep.42Disable Characterp.42Enable Characterp.43Keyboard Interfacep.45Country Modep.45Caps Lock Statep.48Numlockp.48Keyboard Numeric Keypadp.49Keyboard Send Control Charactersp.50Wedge Quiet Intervalp.51Intercharacter Delayp.52Intercode Delayp.53USB Keyboard Speedp.54USB-OEM Interfacep.57Introductionp.57Standard Factory Settingsp.57USB-OEM Device Usagep.58USB-OEM Interface Optionsp.58Wand Emulation Interfacep.59Wand Signal Speedp.59Wand Polarityp.60Wand Idle Statep.60Transmit Noisep.61Label Symbology Conversionp.62Data Formatp.63Global Prefix/Suffixp.64Global AIM IDp.65GS1-128 AIM IDp.65Label IDp.66Label ID: Pre-loaded Setsp.66Label ID: Set Individually Per Symbologyp.67Label ID Controlp.67Label ID Symbology Selectionp.68Set Global Mid Label ID Character(s)p.74Case Conversionp.75Character Conversionp.76Reading Parametersp.77Double Read Timeoutp.78Label Gone Timeoutp.80Power Save Modep.81Sleep Mode Timeoutp.82LED and Beeper Indicatorsp.83Power On Alertp.83Good Read: When to Indicatep.84Good Read Beep Typep.85Good Read Beep Frequencyp.85Good Read Beep Volumep.86Good Read Beep Lengthp.87Illumination Controlp.88Good Read LED Durationp.89Scanning Featuresp.90Scan Modep.90Stand Mode Triggered Timeoutp.91Scanning Active Timep.93Stand Mode Flashp.93Flash On Timep.94Flash Off Timep.94Stand Mode Sensitivityp.95Symbologiesp.97Introductionp.97Standard Factory Settings for Symbologiesp.97Disable All Symbologiesp.98Coupon Controlp.98UPC-Ap.99UPC-A Enable/Disablep.99UPC-A Check Character Transmissionp.99Expand UPC-A to EAN-13p.100UPC-A Number System Character Transmissionp.100In-Store Minimum Readsp.101UPC-Ep.102UPC-E Enable/Disablep.102UPC-E Check Character Transmissionp.102Expand UPC-E to EAN-13p.103Expand UPC-E to UPC-Ap.103UPC-E Number System Character Transmissionp.104UPC-E Minimum Readp.104EAN 13p.105EAN 13 Enable/Disablep.105EAN 13 Check Character Transmissionp.105EAN-13 Flag 1 Characterp.106EAN-13 ISBN Conversionp.106ISSN Enable/Disablep.107EAN 13 Minimum Readsp.107EAN 8p.108EAN 8 Enable/Disablep.108EAN 8 Check Character Transmissionp.108Expand EAN 8 to EAN 13p.109EAN 8 Both Guards Substitutionp.109EAN 8 Guard Insertionp.110EAN 8 Guard Substitutionp.110EAN 8 Minimum Segment Length Blockp.111EAN 8 Minimum Readsp.113EAN 8 Stitch Exact Label Halvesp.114EAN 8 Stitch Unlike Label Halvesp.114EAN Two Labelp.115EAN Two Label Enable/Disablep.115EAN Two Label Combined Transmissionp.115EAN Two Label Minimum Readsp.116UPC/EAN Global Settingsp.117UPC/EAN Decoding Levelp.117UPC/EAN Correlationp.118UPC/EAN Price Weight Checkp.119UPC-A Minimum Readsp.120UPC/EAN Guard Insertionp.121UPC/EAN Stitch Exact Label Halvesp.121UPC/EAN Stitch Unlike Label Halvesp.122UPC/EAN Minimum Segment Lengthp.123Add-Onsp.125Optional Add-onsp.125Optional Add-On Timerp.127P2 Add-Ons Minimum Readsp.129P5 Add-Ons Minimum Readsp.130GS1-128 Add-Ons Minimum Readsp.131GS1 DataBarTM Omnidirectionalp.132GS1 DataBar Omnidirectional Enable/Disablep.132GS1 DataBar Omnidirectional GS1-128 Emulationp.132GS1 DataBar Omnidirectional Minimum Readsp.133GS1 DataBarTM Expandedp.134GS1 DataBar Expanded Enable/Disablep.134GS1 DataBar Expanded GS1-128 Emulationp.134GS1 DataBar Expanded Minimum Readsp.135GS1 DataBar Expanded Length Controlp.136GS1 DataBar Expanded Set Length 1p.136GS1 DataBar Expanded Set Length 2p.137GS1 DataBarTM Limitedp.138GS1 DataBar Limited Enable/Disablep.138GS1 DataBar Limited GS1-128 Emulationp.138GS1 DataBar Limited Minimum Readsp.139Code 39p.140Code 39 Enable/Disablep.140Code 39 Check Character Calculationp.141Code 39 Check Character Transmissionp.142Code 39 Start/Stop Character Transmissionp.142Code 39 Full ASCIIp.143Code 39 Quiet Zonesp.144Code 39 Minimum Readsp.145Code 39 Decoding Levelp.146Code 39 Length Controlp.147Code 39 Set Length 1p.148Code 39 Set Length 2p.149Code 39 Interdigit Ratiop.150Code 39 Character Correlationp.152Code 39 Stitchingp.152Code 32 (Italian Pharmaceutical)p.153Code 32 Enable/Disablep.153Code 32 Feature Setting Exceptionsp.153Code 32 Check Character Transmissionp.154Code 32 Start/Stop Character Transmissionp.154Code 39 CIP (French Pharmaceutical)p.155Code 39 CIP Enable/Disablep.155Code 128p.155Code 128 Enable/Disablep.155Expand Code 128 to Code 39p.156Code 128 Check Character Transmissionp.156Code 128 Function Character Transmissionp.157Code 128 Sub-Code Change Transmissionp.157Code 128 Quiet Zonesp.158Code 128 Minimum Readsp.159Code 128 Decoding Levelp.160Code 128 Length Controlp.161Code 128 Set Length 1p.162Code 128 Set Length 2p.163Code 128 Character Correlationp.164Code 128 Stitchingp.164GS1-128p.165GS1-128 Enablep.165Interleaved 2 of 5 (I 2 of 5)p.166I 2 of 5 Enable/Disablep.166I 2 of 5 Check Character Calculationp.167I 2 of 5 Check Character Transmissionp.168I 2 of 5 Minimum Readsp.169I 2 of 5 Decoding Levelp.170I 2 of 5 Length Controlp.171I 2 of 5 Set Length 1p.172I 2 of 5 Set Length 2p.173I 2 of 5 Character Correlationp.174I 2 of 5 Zero Patternp.174I 2 of 5 Stitchingp.175Interleaved 2 of 5 CIP HRp.175Interleaved 2 of 5 CIP HR Enable/Disablep.175Datalogic 2 of 5p.176Datalogic 2 of 5 Enable/Disablep.176Datalogic 2 of 5 Check Character Calculationp.176Datalogic 2 of 5 Check Character Transmissionp.177Datalogic 2 of 5 Minimum Readsp.177Datalogic 2 of 5 Decoding Levelp.178Datalogic 2 of 5 Length Controlp.178Datalogic 2 of 5 Set Length 1p.179Datalogic 2 of 5 Set Length 2p.180Datalogic 2 of 5 Interdigit Ratiop.181Datalogic 2 of 5 Character Correlationp.183Datalogic 2 of 5 Stitchingp.183Codabarp.184Codabar Enable/Disablep.184Codabar Check Character Calculationp.184Codabar Check Character Transmissionp.185Codabar Start/Stop Character Transmissionp.185Codabar Start/Stop Character Setp.186Codabar Start/Stop Character Matchp.187Codabar Quiet Zonesp.188Codabar Minimum Readsp.189Codabar Decoding Levelp.190Codabar Length Controlp.191Codabar Set Length 1p.192Codabar Set Length 2p.193Codabar Interdigit Ratiop.194Codabar Character Correlationp.196Codabar Stitchingp.196ABC Codabarp.197ABC Codabar Enable/Disablep.197ABC Codabar Concatenation Modep.197ABC Codabar Dynamic Concatenation Timeoutp.198ABC Codabar Force Concatenationp.198Code 11p.199Code 11 Enable/Disablep.199Code 11 Check Character Calculationp.200Code 11 Check Character Transmissionp.200Code 11 Minimum Readsp.201Code 11 Length Controlp.202Code 11 Set Length 1p.202Code 11 Set Length 2p.203Code 11 Interdigit Ratiop.204Code 11 Decoding Levelp.206Code 11 Character Correlationp.207Code 11 Stitchingp.207Standard 2 of 5p.208Standard 2 of 5 Enable/Disablep.208Standard 2 of 5 Check Character Calculationp.208Standard 2 of 5 Check Character Transmissionp.209Standard 2 of 5 Minimum Readsp.209Standard 2 of 5 Decoding Levelp.210Standard 2 of 5 Length Controlp.210Standard 2 of 5 Set Length 1p.211Standard 2 of 5 Set Length 2p.212Standard 2 of 5 Character Correlationp.213Standard 2 of 5 Stitchingp.213Industrial 2 of 5p.214Industrial 2 of 5 Enable/Disablep.214Industrial 2 of 5 Check Character Calculationp.214Industrial 2 of 5 Check Character Transmissionp.215Industrial 2 of 5 Length Controlp.215Industrial 2 of 5 Set Length 1p.216Industrial 2 of 5 Set Length 2p.217Industrial 2 of 5 Minimum Readsp.218Industrial 2 of 5 Stitchingp.219Industrial 2 of 5 Character Correlationp.219IATAp.220IATA Enable/Disablep.220IATA Check Character Transmissionp.220ISBT 128p.221ISBT 128 Concatenationp.221ISBT 128 Concatenation Modep.221ISBT 128 Dynamic Concatenation Timeoutp.222ISBT 128 Force Concatenationp.223ISBT 128 Advanced Concatenation Optionsp.223MSIp.224MSI Enable/Disablep.224MSI Check Character Calculationp.224MSI Check Character Transmissionp.225MSI Length Controlp.225MSI Set Length 1p.226MSI Set Length 2p.227MSI Minimum Readsp.228MSI Decoding Levelp.229Code 93p.230Code 93 Enable/Disablep.230Code 93 Check Character Calculationp.230Code 93 Check Character Transmissionp.231Code 93 Length Controlp.231Code 93 Set Length 1p.232Code 93 Set Length 2p.233Code 93 Minimum Readsp.234Code 93 Decoding Levelp.235Code 93 Quiet Zonesp.236Code 93 Stitchingp.237Code 93 Character Correlationp.237Codablock Fp.238Codablock F Enable/Disablep.238Codablock F EAN Enable/Disablep.238Codablock F AIM Checkp.239Codablock F Length Controlp.239Codablock F Set Length 1p.240Codablock F Set Length 2p.241Code 4p.242Code 4 Enable/Disablep.242Code 4 Check Character Transmissionp.242Code 4 Hex to Decimal Conversionp.243Code 5p.243Code 5 Enable/Disablep.243Code 5 Check Character Transmissionp.244Code 5 Hex to Decimal Conversionp.244Code 4 and Code 5 Common Configuration Itemsp.245Code 4 and 5 Decoding Levelp.245Code 4 and Code 5 Minimum Readsp.246Follett 2 of 5p.247Follett 2 of 5 Enable/Disablep.247BC412p.247BC412 Enable/Disablep.247BC412 Check Character Calculationp.248BC412 Minimum Readsp.248BC412 Decoding Levelp.249BC412 Length Controlp.250BC412 Set Length 1p.250BC412 Set Length 2p.251Plesseyp.252Plessey Enable/Disablep.252Plessey Check Character Calculationp.253Plessey Check Character Transmissionp.254Plessey Length Controlp.254Plessey Set Length 1p.255Plessey Set Length 2p.256Plessey Minimum Readsp.257Plessey Decoding Levelp.258Plessey Stitchingp.259Plessey Character Correlationp.259Referencesp.261RS-232 Parametersp.262RS-232 Onlyp.262RS-232/USB COM Parametersp.263Keyboard Interfacep.270Wedge Quiet Intervalp.270Intercharacter Delayp.271Intercode Delayp.272Data Formatp.273Data Editingp.273Global Prefix/Suffixp.274Global AIM IDp.275Label IDp.276Set Global Mid Label ID Character(s)p.280Character Conversionp.280Reading Parametersp.282Label Gone Timeoutp.282Good Read LED Durationp.283Scanning Featuresp.284Scan Modep.284Scanning Active Timep.285Flash On Timep.286Flash Off Timep.287Symbologiesp.288Decoding Levelsp.288Set Lengthp.288Technical Specificationsp.291Standard Cable Pinoutsp.293LED and Beeper Indicationsp.294Error Codesp.295Standard Defaultsp.297Default Exceptionsp.308Sample Bar Codesp.3111D Bar Codesp.311GS1 DataBar (RSS)p.313GS1 DataBar-14p.313Keypadp.315Scancode Tablesp.319Control Character Emulationp.319Interface Type PC AT PS/2 or USB-Keyboardp.320Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Modep.322Digital Interfacep.324IBM XTp.326Microsoft Windows Codepage 1252p.328ASCII Chartp.331
Page 262 of the Solis 842 user manual — Handshaking Control
Page 262 · click to enlarge
Page 262

RS-232 Parameters

RS-232 Only

Baud Rate

Baud rate is the number of bits of data transmitted per second. Set the reader's baud rate to match the baud rate setting of the host device. With an improper baud rate setting, data may not reach the host correctly.

Stop Bits

The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits selected (one or two) depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.

Parity

This feature specifies parity required for sending and receiving data. A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements.

  • Select None when no parity bit is required.
  • Select Odd parity and the parity bit value is set to 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character.
  • Select Even parity and the parity bit value is set to 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character.

Handshaking Control

The data interface consists of an RS-232 port designed to operate either with or without the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). Handshaking Control includes the following options:

  • RTS — RTS is asserted during transmissions. CTS is ignored.
  • RTS/CTS — RTS is asserted during transmissions. CTS gates transmissions.
  • RTS/XON/XOFF — RTS is asserted during transmissions. CTS is ignored. XON and XOFF gate transmissions.
  • RTS On/CTS — RTS is always asserted. CTS gates transmissions.
  • RTS/CTS Scan Control — RTS is asserted during transmissions. CTS gates transmissions and controls enable and disable state of scanner.

References RS-232 Parameters

Page 263 of the Solis 842 user manual — STEP ACTION EXAMPLES
Page 263 · click to enlarge
Page 263

RS-232/USB COM Parameters

Intercharacter Delay

This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay.

To set the delay:

1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with lead ing zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
4. Go to page 25 and scan the bar code: SELECT INTERCHARACTER DELAY SET TING.
5. Scan the appropriate two digits from the keypad in Appendix D, Keypad , that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character.

If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.

This completes the procedure. See the following table for examples of how to set this feature.

Table 4. Intercharacter Delay Setting Examples

STEP ACTION EXAMPLES

1 Desired Setting 50ms 150ms 600ms 850ms

2 Divide by 10 (pad with leading

zeroes to yield two-digits) 05 15 60 85

3 Scan ENTER/EXIT PROGRAMMING MODE

4 Scan SELECT INTERCHARACTER DELAY SETTING

5 Scan Two Characters From

Appendix D, Keypad ‘0’ and ‘5’ ‘5’ and ‘0’ ‘6’ and ‘0’ ‘8’ and ‘5’

6 Scan ENTER/EXIT PROGRAMMING MODE

RS-232 Parameters References

Page 264 of the Solis 842 user manual — STEP ACTION EXAMPLES
Page 264 · click to enlarge
Page 264

ACK NAK Options

This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. When configured, the reader and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error.

Options are:

  • Disable
  • Enable for label transmission — The reader expects an ACK/NAK response from the host when a label is sent
  • Enable for host-command acknowledge — The reader will respond with ACK/NAK when the host sends a command
  • Enable for label transmission and host-command acknowledge

ACK Character

This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected.

Setting to previously defined characters such as XON, XOFF, or host com- mands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits.

NOTE

1. Determine the desired character or value.
2. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent for the desired character/value.
3. Go to page 28 and scan ENTER/EXIT PROGRAMMING MODE to enter Program ming Mode.
4. Scan the bar code: SELECT ACK CHARACTER SETTING.
5. Scan the appropriate two alphanumeric characters from the keypad in Appendix D, Keypad , that represent the desired character/value determined above. The second character will cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.

See the table below for examples of how to set this feature.

Table 5. ACK Character Setting Examples

STEP ACTION EXAMPLES

1 Desired Character/Value ACK $ @ >

2 Hex equivalent from ASCII Chart 0x06 0x24 0x40 0x3E

3 Scan ENTER/EXIT PROGRAMMING MODE

4 Scan SELECT ACK CHARACTER SETTING

5 Scan Two Characters from

Appendix D, Keypad ‘0’ and ‘6’ ‘2’ and ‘4’ ‘4’ and ‘0’ ‘3’ AND ‘E’

6 Scan ENTER/EXIT PROGRAMMING MODE

References RS-232 Parameters

Page 265 of the Solis 842 user manual — STEP ACTION EXAMPLES
Page 265 · click to enlarge
Page 265

NAK Character

This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected.

Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8- bit data is not recognized when the option Data Bits has been set as 7 Data Bits.

NOTE

To set this feature:

1. Determine the desired character or value.
2. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent for the desired character/value.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
4. Scan the bar code: SELECT NAK CHARACTER SETTING.
5. Scan the appropriate two alpha-numeric characters from the keypad in Appendix D, Keypad , that represent the desired character/value determined above. The second character will cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.

This completes the procedure. See the table below for examples of how to set this feature.

Table 6. NAK Character Setting Examples

STEP ACTION EXAMPLES

1 Desired Character/Value NAK $ @ >

2 Hex equivalent 0x15 0x24 0x40 0x3E

3 Scan ENTER/EXIT PROGRAMMING MODE

4 Scan SELECT NAK CHARACTER SETTING

5 Scan Two Characters From Appendix D, Keypad ‘1’ and ‘5’ ‘2’ and ‘4’ ‘4’ and ‘0’ ‘3’ AND ‘E’

6 Scan ENTER/EXIT PROGRAMMING MODE

RS-232 Parameters References

Page 266 of the Solis 842 user manual — STEP ACTION EXAMPLES
Page 266 · click to enlarge
Page 266

ACK NAK Timeout Value

This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout.

To set this value:

1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 200 (setting is in 200ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Go to page 29 and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
4. Scan the bar code: SELECT ACK NAK TIMEOUT VALUE SETTING.
5. Scan the appropriate two digits from the keypad in Appendix D, Keypad , that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character.

If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.

This completes the procedure. See the table below for examples of how to set this feature.

Table 7. ACK NAK Timeout Value Setting Examples

STEP ACTION EXAMPLES

1 Desired Setting 200ms 1,000ms (1 sec.) 5200ms (5.2 sec.) 15,000ms (15 sec.)

2 Divide by 200 01 05 26 75

3 Scan ENTER/EXIT PROGRAMMING MODE

4 Scan SELECT ACK NAK TIMEOUT VALUE SETTING

5 Scan Two Characters From

Appendix D, Keypad ‘0’ and ‘1’ ‘0’ and ‘5’ ‘2’ and ‘6’ ‘7’ and ‘5’

6 Scan ENTER/EXIT PROGRAMMING MODE

References RS-232 Parameters

Page 267 of the Solis 842 user manual — STEP ACTION EXAMPLES
Page 267 · click to enlarge
Page 267

ACK NAK Retry Count

This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries.

To set this feature:

1. Determine the desired setting.
2. Pad the number with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc.
3. Go to page 30 and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
4. Scan the bar code: SELECT ACK NAK RETRY COUNT SETTING.
5. Scan the appropriate three digits from the keypad in Appendix D, Keypad , that represent the number which was determined in the steps above. You will hear a two-beep indication after the last character.

If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.

This completes the procedure. See the table below for examples of how to set this feature.

Table 8. ACK NAK Retry Count Setting Examples

STEP ACTION EXAMPLES

1 Desired Setting Disable Retry

Count 3 Retries 54 Retries Unlimited Retries

2 Pad with leading zero(es) 000 003 054 255

3 Scan ENTER/EXIT PROGRAMMING MODE

4 Scan SELECT ACK NAK RETRY COUNT SETTING

5 Scan Three Characters From

Appendix D, Keypad ‘0’, ‘0’ and ‘0’ ‘0’, ‘0’ and ‘3’ ‘0’, ‘5’ and ‘4’ ‘2’, ‘5’ and ‘5’

6 Scan ENTER/EXIT PROGRAMMING MODE

RS-232 Parameters References

Page 268 of the Solis 842 user manual — STEP ACTION EXAMPLES
Page 268 · click to enlarge
Page 268

Disable Character

Specifies the value of the RS-232 host command used to disable the reader.

ASCII characters or any hex value from 0 to 0xFF can be selected.

Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8- bit data is not recognized when the option Data Bits has been set as 7 Data Bits.

NOTE

To set the value:

1. Determine the desired character or value. A setting of 0xFF indicates the Disable Character is not used (not available).
2. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent for the desired character/value.
3. Go to page 32 and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
4. Scan the bar code: SELECT DISABLE CHARACTER SETTING.
5. Scan the appropriate two alphanumeric characters from the keypad in Appendix D, Keypad , that represent the desired character/value determined above. The second character will cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.

This completes the procedure. See the table below for examples of how to set this feature.

Table 9. Disable Character Setting Examples

STEP ACTION EXAMPLES

1 Desired character/value ‘d’ ‘}’ ‘D’ Disable Command

2 Hex equivalent from ASCII Chart 0x64 0x7D 0x44 0xFF

3 Scan ENTER/EXIT PROGRAMMING MODE

4 Scan SELECT DISABLE CHARACTER VALUE SETTING

5 Scan Two Characters From

Appendix D, Keypad ‘6’ and ‘4’ ‘7’ and ‘D’ ‘4’ and ‘4’ ‘F’ AND ‘F’

6 Scan ENTER/EXIT PROGRAMMING MODE

References RS-232 Parameters · Not Used

Page 269 of the Solis 842 user manual — STEP ACTION EXAMPLES
Page 269 · click to enlarge
Page 269

Enable Character

Specifies the value of the RS-232 host command used to enable the reader.

ASCII characters or any hex value from 0 to 0xFF can be selected.

Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8- bit data is not recognized when the option Data Bits has been set as 7 Data Bits.

NOTE

To set this feature:

Determine the desired character or value. A setting of 0xFF indicates the Enable Character is not used (not available).

1. Determine the desired character or value.
2. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent for the desired character/value.
3. Go to page 33 and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
4. Scan the bar code: SELECT ENABLE CHARACTER SETTING.
5. Scan the appropriate two alphanumeric characters from the keypad in Appendix D, Keypad , that represent the desired character/value determined above. The second character will cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.

This completes the procedure. See the table below for examples of how to set this feature.

Table 10. Enable Character Setting Examples

STEP ACTION EXAMPLES

1 Desired character/value ‘e’ ‘}’ ‘E’ Enable Command

2 Hex equivalent from ASCII Chart 0x65 0x7D 0x45 0xFF

3 Scan ENTER/EXIT PROGRAMMING MODE

4 Scan SELECT ENABLE CHARACTER VALUE SETTING

5 Scan Two Characters From

Appendix D, Keypad ‘6’ and ‘5’ ‘7’ and ‘D’ ‘4’ and ‘5’ ‘F’ AND ‘F’

6 Scan ENTER/EXIT PROGRAMMING MODE

RS-232 Parameters References · Not Used

Page 270 of the Solis 842 user manual — STEP ACTION EXAMPLES
Page 270 · click to enlarge
Page 270

Keyboard Interface

Wedge Quiet Interval

Specifies the amount of time the reader looks for keyboard activity before it breaks the keyboard connection in order to transmit data to host. The range is from 0 to 990ms in 10ms increments.

This feature applies ONLY to the Keyboard Wedge interface.

NOTE

1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with lead ing zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Go to page 41 and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Prog. Mode.
4. Scan the bar code: SELECT WEDGE QUIET INTERVAL SETTING.
5. Scan the appropriate two digits from the keypad in Appendix D, Keypad , that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character.

If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.

This completes the procedure to set the Wedge Quiet Interval. See the table below for examples of how to set this feature.

Table 11. Wedge Quiet Interval Setting Examples

STEP ACTION EXAMPLES

1 Desired Setting 10ms 150ms 600ms 850ms

2 Divide by 10 (and pad with

leading zeroes) 01 15 60 85

3 Scan ENTER/EXIT PROGRAMMING MODE

4 Scan SELECT WEDGE QUIET INTERVAL SETTING

5 Scan Two Characters From

Appendix D, Keypad ‘0’ and ‘1’ ‘1’ and ‘5’ ‘6’ and ‘0’ ‘8’ and ‘5’

6 Scan ENTER/EXIT PROGRAMMING MODE

References Keyboard Interface

Page 271 of the Solis 842 user manual — STEP ACTION EXAMPLES
Page 271 · click to enlarge
Page 271

Intercharacter Delay

This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay.

This feature applies ONLY to the Keyboard Wedge interface.

NOTE

To set the delay:

1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with lead ing zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Go to page 42 and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
4. Scan the bar code: SELECT INTERCHARACTER DELAY SETTING.
5. Scan the appropriate two digits from the keypad in Appendix D, Keypad , that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character.

If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.

This completes the procedure. See the table below for examples of how to set this feature.

Table 12. Intercharacter Delay Setting Examples

STEP ACTION EXAMPLES

1 Desired Setting 50ms 150ms 600ms 850ms

2 Divide by 10 (and pad with leading zeroes to yield two-

05 15 60 85

3 Scan ENTER/EXIT PROGRAMMING MODE

4 Scan SELECT INTERCHARACTER DELAY SETTING

5 Scan Two Characters From

Appendix D, Keypad ‘0’ and ‘5’ ‘1’ and ‘5’ ‘6’ and ‘0’ ‘8’ and ‘5’

6 Scan ENTER/EXIT PROGRAMMING MODE

Keyboard Interface References · digits)

Page 272 of the Solis 842 user manual — STEP ACTION EXAMPLES
Page 272 · click to enlarge
Page 272

Intercode Delay

Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds.

Follow these instructions to set this feature:

1. Determine the desired setting.
2. Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc
3. Go to page 43 and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
4. Scan the bar code: SELECT INTERCODE DELAY SETTING.
5. Scan the appropriate two digits from the keypad in Appendix D, Keypad , that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character.

If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.

This completes the procedure. See the table below for examples of how to set this feature.

Table 13. Wedge Intercode Delay Examples

STEP ACTION EXAMPLES

1 Desired Setting No Delay 5 Seconds 60 Seconds 99 Seconds

2 Pad with leading zero(es) 00 05 60 99

3 Scan ENTER/EXIT PROGRAMMING MODE

4 Scan SELECT INTERCODE DELAY SETTING

5 Scan Two Characters From

Appendix D, Keypad ‘0’ and ‘0’ ‘0’ and ‘5’ ‘6’ and ‘0’ ‘9’ AND ‘9’

6 Scan ENTER/EXIT PROGRAMMING MODE

References Keyboard Interface

Page 273 of the Solis 842 user manual — NOTE
Page 273 · click to enlarge
Page 273

Data Format

Data Editing

When a bar code is scanned, additional information can be sent to the host computer along with the bar code data. This combination of bar code data and supplementary user-defined data is called a “message string.” The Data Editing features can be used to build specific user-defined data into a message string.

There are several types of selectable data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with specific symbologies. The following shows the available elements you can add to a message string:

Figure 3. Breakdown of a Message String

Label ID Transmission:

Enable this option to transmit the Label ID you configure for the scanned

symbology.

OR...

Prefix Suffix AIM ID Label ID Label ID Bar Code Data

AIM ID: This function is used to identify and display the common label identifier for its symbology. When enabled, this ID code will be transmitted before the scanned bar code data.

0. 20 Characters (ASCII)

Additional advanced editing is available. See the Advanced formatting fea- tures in the Datalogic Aladdin configuration software, or contact Technical Support (as described on page 2) for more information.

NOTE

Please Keep In Mind...

  • Modifying a message string is not a mandatory requirement. Data editing is a sophisti cated feature allowing highly customizable output for advanced users. Factory default set tings for data editing is typically set to NONE.
  • A prefix or suffix may be applied only to a specified symbology (reference Symbologies, starting on page 87 ) or across all symbologies (set via the Global features in Con figuration Using Bar Codes, starting on page 15 ).
  • You can add any character from the ASCII Chart (from 00-FF) on the inside back cover of this manual as a prefix, suffix or Label ID.
  • Enter prefixes and suffixes in the order in which you want them to appear on the output.

Data Format References

Page 274 of the Solis 842 user manual — NOTE
Page 274 · click to enlarge
Page 274

Global Prefix/Suffix

Up to 20 ASCII characters may be added as a prefix (in a position before the bar code data) and/ or as a suffix (in a position following the bar code data) as indicated.

Figure 4. Prefix and Suffix Positions

OR...

Prefix Suffix AIM ID Label ID Label ID Bar Code Data

0. 20 Characters (ASCII)

Example: Setting a Prefix

In this example, we’ll set a prefix for all symbologies.

1. Determine which ASCII character(s) are to be added to scanned bar code data. In this example, we’ll add a dollar sign (‘$’) as a prefix.
2. Go to page 54 and scan the ENTER/EXIT PROGRAMMING MODE bar code, then scan the SET GLOBAL PREFIX bar code.
3. Reference the ASCII Chart on the inside back cover of this manual to find the hex value assigned to the desired character. The corresponding hex number for the ‘$’ character is 24. To enter this selection code, scan the ‘2’ and ‘4’ bar codes from Appendix D, Keypad .

If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

NOTE

4. If less than the expected string of 20 characters are selected, scan the ENTER/EXIT bar code to terminate the string.
5. Scan the ENTER/EXIT bar code once again to exit Programming Mode.
6. The resulting message string would appear as follows: Scanned bar code data: 12345 Resulting message string output: $12345

References Data Format

Page 275 of the Solis 842 user manual — SYMBOLOGY CHAR SYMBOLOGY CHAR
Page 275 · click to enlarge
Page 275

Global AIM ID

This feature enables/disables addition of AIM IDs for all symbology types.

NOTE

AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data. AIM label identifiers consist of three characters as follows:

  • A close brace character (ASCII ‘]’), followed by...
  • A code character (see the table below), followed by...
  • A modifier character (the modifier character is symbol dependent).

SYMBOLOGY CHAR SYMBOLOGY CHAR

Code 39 and Code 32 A DataBar Omnidirectional, DataBar Expanded e

Codabar F Standard 2 of 5 S

Interleaved 2 of 5 I ISBN Xb

Code 93 G Code 11 H

a. UPC-A and UPC-E labels are converted to EAN 13 when adding AIM IDs.

b. ISBN (X with a 0 modifier character)

Figure 5. AIM ID

Prefix Suffix Label ID Label ID Bar Code Data AIM ID

Data Format References · UPC/EAN Ea · Code 128/GS1-128 C

Page 276 of the Solis 842 user manual — EAN13 F 460000 B 420000
Page 276 · click to enlarge
Page 276

Label ID

A Label ID is a customizable code of up to three ASCII characters (each can be one of hex 0x01- 0xFF), used to identify a bar code (symbology) type. It can be appended previous to or following the transmitted bar code data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs as a pre-loaded set or individually per symbology (see "Label ID: Set Individually Per Symbology" on page 57). If you wish to program the reader to always include an industry standard label identifier for ALL symbology types, see "Global AIM ID" on page 55.

Label ID: Pre-loaded Sets

The following table lists the pre-loaded label ID sets for the USA and Europe.

Table 14. Label ID Pre-loaded Sets

Symbology USA Label ID set EU Label ID set

ABC Codabar S 530000 S 530000

CODABAR % 250000 R 520000

Codablock F l 6C0000 m 6D0000

Code 39 CIP Y 590000 Y 590000

Code 93 & 260000 U 550000

CODE11 CE 434500 b 620000

CODE128 # 230000 T 540000

CODE32 A 410000 X 580000

CODE39 * 2A0000 V 560000

CODE4 4 340000 4 340000

CODE5 j 6A0000 j 6A0000

CODE93 & 260000 U 550000

DATALOGIC 2OF5 s 730000 s 730000

EAN13 F 460000 B 420000

EAN13 P2 F 460000 L 4C0000

EAN13 P5 F 460000 M 4D0000

EAN13 P8 F 460000 # 230000

EAN8 FF 464600 A 410000

EAN8 P2 FF 464600 J 4A0000

EAN8 P5 FF 464600 K 4B0000

Show 6 more labels / short text on this page
References Data Format · ASCII character · Hex value · ASCII character · Hexadecimal · value
Page 277 of the Solis 842 user manual — UPCA A 410000 C 430000
Page 277 · click to enlarge
Page 277

Symbology USA Label ID set EU Label ID set

EAN8 P8 FF 464600 * 2A0000

FOLLETT 2OF5 O 4F0000 O 4F0000

GS1 DATABAR EXPANDED RX 525800 t 740000

GS1 DATABAR LIMITED RL 524C00 v 760000

GS1 DATABAR OMNIDIRECTIONAL R4 523400 u 750000

GS1-128 000000 k 6B0000

I2OF5 i 690000 N 4E0000

IATA IA 494100 & 260000

Industrial 2 of 5 W 570000 W 570000

Interleaved 2 of 5 CIP HR e 650000 e 650000

ISBN I 490000 @ 400000

ISBT128 f 660000 f 660000

ISSN n 6E0000 n 6E0000

MSI @ 400000 Z 5A0000

S25 s 730000 P 500000

UPCA A 410000 C 430000

UPCA P2 A 410000 F 460000

UPCA P5 A 410000 G 470000

UPCA P8 A 410000 Q 510000

UPCE E 450000 D 440000

UPCE P2 E 450000 H 480000

UPCE P5 E 450000 I 490000

UPCE P8 E 450000 E 450000

Data Format References

Page 278 of the Solis 842 user manual — OR
Page 278 · click to enlarge
Page 278

Label ID: Set Individually Per Symbology

To configure a Label ID individually for a single symbology:

1. Scan the ENTER/EXIT bar code.
2. Select Label ID position as either BEFORE (Enable as Prefix) or AFTER (Enable as suf fix) by scanning the appropriate bar code in the section "Label ID Control" on page 57 . Refer ence Figure 6 for Label ID positioning options if multiple identification features are enabled.
3. Scan a bar code to select the symbology for which you wish to configure a custom Label ID from the section Label ID Symbology Selection, starting on page 58 .
4. Determine the desired character(s) (you may choose up to three) which will represent the Label ID for the selected symbology.

5. Turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID. For example, if you wish to select an equal sign (=) as a Label ID, the chart indicates its associated hex characters as 3D. Turn to Keypad, starting on page 305 and scan the bar codes representing the hex characters deter mined. For the example given, the characters ‘3’ and ‘D’ would be scanned. More exam ples of Label ID settings are provided in Table 15.

If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

NOTE

6. Scan the ENTER/EXIT bar code to exit Label ID entry.
7. Scan the ENTER/EXIT bar code once again to exit Programming Mode.

This completes the steps to configure a Label ID for a given symbology.

Figure 6. Label ID Position Options

Prefix Suffix Label ID Label ID Bar Code Data Aim ID

OR

References Data Format

Page 279 of the Solis 842 user manual — STEP ACTION EXAMPLES
Page 279 · click to enlarge
Page 279

Label ID: Set Individually Per Symbology — continued

. Label ID Examples

STEP ACTION EXAMPLES

1. Scan the ENTER/EXIT bar code (Reader enters Programming Mode)

Determine placement of the Label ID characters BEFORE or AFTER with regard to scanned data using "Label ID Control" on page 57

Enable as Prefix Enable as Suffix Enable as Prefix Enable as Suffix

Scan the bar code selecting the symbology type you wish to designate label ID characters for using Label ID Symbology Selection, starting on page 58.

GS1 DataBar Omnidirectional Code 39 Interleaved 2 of

4. Custom Label ID example (desired characters): D B * = C 3 + P H

Find hex equivalents from the ASCII table (inside back cover), then scan in these digits/ characters using the bar codes in the section: Keypad, starting on page 305. f you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

44 42 2A 3D 43 33 2B 50 48

6. Scan the ENTER/EXIT bar code (Reader exits Label ID entry)
7. Scan the ENTER/EXIT bar code once again (Reader exits Programming Mode)
ResultDB*[bar code

data] [bar code data]PH

Show 6 more labels / short text on this page
Data Format References · Table 15 · 5 Code 32 · [bar code data]=C3 · +[bar code · data]
Page 280 of the Solis 842 user manual — Character Conversion
Page 280 · click to enlarge
Page 280

References Set Global Mid Label ID Character(s)

Set Global Mid Label ID Character(s)

Specifies a mid-label ID that is added for transmission between the labels of a two label pair. The expected string is a maximum of 20 characters. When combining two label pairs into a single label for transmission to the host, this label ID can be added to the data, following the first label and preceding the second label.

1. Scan the ENTER/EXIT bar code.
2. Scan the bar code in "Set Global Mid Label ID Character(s)" on page 64
3. Determine the desired character(s) (you may choose up to twenty) which will represent the Mid Label ID for two label pairs. If the first character is 00, then nothing is added between the two labels.

4. Turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID. For example, if you wish to select the char acters ‘M’, ‘I’ and ‘D’ as a Label ID, the chart indicates its associated hex characters as 4D4944. Turn to Keypad, starting on page 305 and scan the bar codes representing the hex characters determined. For the example given, the characters ‘4’, ‘D’, ‘4’, ‘9’, ‘4’ and ‘4’ would be scanned. More examples of Label ID settings are provided in Table 15.

If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

NOTE

5. The reader will save the string and exit Programming Mode when:
  • the ENTER/EXIT bar code is scanned a second time, or
  • the hex values for all twenty available characters have been entered, or
  • the first 00 hex value entered terminates the string.

This completes the steps to configure a Global Mid Label ID for two label pairs.

Character Conversion

Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done.

For example, if you have the character conversion configuration item set to the following: 41423132FFFFFFFF

The first pair is 4142 or AB (41 hex is an ASCII capital A, 42 hex is an ASCII capital B) and the second pair is 3132 or 12 (31 hex is an ASCII 1, 32 is an ASCII 2). The other two pairs are FFFF and FFFF.

With the label, AB12BA21, it would look as follows after the character

conversion: BB22BB22.

Page 281 of the Solis 842 user manual — NOTE
Page 281 · click to enlarge
Page 281

Set Global Mid Label ID Character(s) References

The A characters were converted to B characters and the 1 characters were converted to 2 characters. Nothing is done with the last two character pairs, since they are all FF.

To set Character Conversion:

1. Scan the ENTER/EXIT bar code.
2. Scan the bar code for "Character Conversion" on page 66
3. Determine the desired string. Sixteen positions must be determined as in the above exam ple. Next, turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits needed to fulfill the string.
4. Turn to Appendix D, Keypad and scan the bar codes representing the hex characters deter mined in the previous step.
5. Scan the ENTER/EXIT bar code to exit Programming Mode.

If less than the expected string of 16 characters are selected, scan the ENTER/EXIT bar code twice to accept the selections and exit Pro- gramming Mode.

NOTE

Page 282 of the Solis 842 user manual — STEP ACTION EXAMPLES
Page 282 · click to enlarge
Page 282

Reading Parameters

Label Gone Timeout

This feature sets the time after the last label segment is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55 seconds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a trigger pull for each label that is read

Follow these instructions to set this feature:

1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with lead ing zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
4. Scan the bar code: SELECT LABEL GONE TIMEOUT SETTING.
5. Scan the appropriate three alpha-numeric characters from the keypad in Appendix D, Key pad representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character.

If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.

This completes the procedure. See the table below for examples of how to set this feature.

Table 16. Timeout Setting Examples

STEP ACTION EXAMPLES

1 Desired Setting 50ms 150ms 1800ms (1.8 sec.) 2550ms (2.55 sec.)

2 Divide by 10 (and pad with leading zeroes) 005 015 180 255

3 Scan ENTER/EXIT PROGRAMMING MODE

4 Scan SELECT LABEL GONE TIMEOUT SETTING

5 Scan Three Characters From Appendix D, Keypad ‘0’, ‘0’ and ‘5’ ‘0’, ‘1’ and ‘5’ ‘1’, ‘8’ and ‘0’ ‘‘2’, ‘5’ and ‘5’

6 Scan ENTER/EXIT PROGRAMMING MODE

References Reading Parameters

Page 283 of the Solis 842 user manual — STEP ACTION EXAMPLES
Page 283 · click to enlarge
Page 283

Good Read LED Duration

This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 0.1 to 25.5 seconds in 100ms increments.

Follow these instructions to set this feature:

1. Determine the desired setting in milliseconds. A setting of 0 means that the good read LED stays on until the next time the trigger is pulled.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 000, 20 = 020, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
4. Scan the bar code: SELECT GOOD READ LED DURATION SETTING.
5. Scan the appropriate three digits from the keypad in Appendix D, Keypad representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character.

If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.

This completes the procedure. See the table below for examples of how to set this feature.

Table 17. Good Read LED Duration Setting Examples

STEP ACTION EXAMPLES

stays on until next trigger pull

200ms 1500ms (1.5 sec.) 2500ms (2.5 sec.)

2 Divide by 100 (and pad with leading zeroes) 000 002 015 025

3 Scan ENTER/EXIT PROGRAMMING MODE

4 Scan SELECT GOOD READ LED DURATION SETTING

5 Scan Three Characters From Appendix D, Keypad ‘0’, ‘0’ and ‘0’ ‘0’, ‘0’ and ‘2’ ‘0’, ‘1’ and ‘5’ ‘0’, ‘2’ and ‘5’

6 Scan ENTER/EXIT PROGRAMMING MODE

Show 4 more labels / short text on this page
Reading Parameters References · Good Read LED · 1 Desired Setting · (00)
Page 284 of the Solis 842 user manual — Scan Mode
Page 284 · click to enlarge
Page 284

Scanning Features

Scan Mode

Selects the scan operating mode for the reader. Selections are:

Trigger SingleWhen the trigger is pulled, scanning is activated until one of the following occurs:

- Scanning Active Time has elapsed - a label has been read - the trigger is released

This mode is associated with typical handheld reader operation: when the trigger is pulled, scanning starts and the product scans until the trigger is released, or a label is read, or the maximum Scanning Active Time has elapsed.

Trigger Hold Multiple : When the trigger is pulled, scanning starts and the product scans until the trigger is released or Scanning Active Time has elapsed. Reading a label does not disable scanning. Double Read Timeout prevents undesired multiple reads of the same label while in this mode.

Trigger Pulse Multiple: When the trigger is pulled, continuous scanning is activated until Scanning Active Time has elapsed or the trigger has been released and pulled again. Double Read Timeout prevents undesired multiple reads of the same label while in this mode.

Flashing: The reader flashes1 on and off regardless of the trigger status. Flash rate is controlled by Flash On Time and Flash Off Time. When Flash is ON the reader reads continuously. When Flash is OFF scanning is deactivated.

Always On: No trigger pull is required to read a bar code. Scanning is continually on. Double Read Timeout prevents undesired multiple reads of the same label while in this mode.

Stand Mode: No trigger pull is required to read a bar code. Scanning turns on automatically when an item is placed in reader's field of view. While in a stand watch state, the reader illumination LED goes from dim to maximum bright.

1Controlled by Flash On Time.

References Scanning Features

Page 285 of the Solis 842 user manual — STEP ACTION EXAMPLES
Page 285 · click to enlarge
Page 285

Scanning Active Time

This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments.

Follow these instructions to set this feature:

1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
4. Scan the bar code: SELECT SCANNING ACTIVE TIME SETTING.
5. Scan the appropriate three digits from the keypad in Appendix D, Keypad , that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character.

If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.

This completes the procedure. See the table below for examples of how to set this feature.

Table 18. Scanning Active Time Setting Examples

STEP ACTION EXAMPLES

1 Desired Setting 1 Second 90 Sec. (1.5 min.) 180 Sec. (3 min.) 255 Seconds (4.25 min.)

2 Pad leading zero(es) 001 090 180 255

3 Scan ENTER/EXIT PROGRAMMING MODE

4 Scan SELECT SCANNING ACTIVE TIME SETTING

5 Scan Three Characters From Appendix D, Keypad ‘0’, ‘0’ and ‘1’ ‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’ ‘2’, ‘5’ and ‘5’

6 Scan ENTER/EXIT PROGRAMMING MODE

Scanning Features References

Page 286 of the Solis 842 user manual — STEP ACTION EXAMPLES
Page 286 · click to enlarge
Page 286

Flash On Time

This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments.

Follow these instructions to set this feature.

1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
4. Scan the bar code: SELECT FLASH ON TIME SETTING.
5. Scan the appropriate two digits from the keypad in Appendix D, Keypad representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character.

If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.

This completes the procedure. See the table below for examples of how to set this feature.

Table 19. Flash On Time Setting Examples

STEP ACTION EXAMPLES

1 Desired Setting 500ms 1,000ms (1 sec.) 5200ms (5.2 sec.) 9,900ms (9.9 sec.)

2 Divide by 100 (and pad with leading zeroes to yield two digits)

05 10 52 99

3 Scan ENTER/EXIT PROGRAMMING MODE

4 Scan SELECT FLASH ON TIME SETTING

5 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘5’ ‘1’ and ‘0’ ‘5’ and ‘2’ ‘9’ and ‘9’

6 Scan ENTER/EXIT PROGRAMMING MODE

References Scanning Features

Page 287 of the Solis 842 user manual — STEP ACTION EXAMPLES
Page 287 · click to enlarge
Page 287

Flash Off Time

This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments.

Follow these instructions to set this feature.

1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
4. Scan the bar code: SELECT FLASH OFF TIME SETTING.
5. Scan the appropriate two digits from the keypad in Appendix D, Keypad , that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character.

If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.

This completes the procedure. See the table below for examples of how to set this feature.

Table 20. Flash Off Time Setting Examples

STEP ACTION EXAMPLES

1 Desired Setting 500ms 1,000ms (1 sec.) 5200ms (5.2 sec.) 9,900ms (9.9 sec.)

2 Divide by 100 (and pad with leading zeroes to yield two digits)

05 10 52 99

3 Scan ENTER/EXIT PROGRAMMING MODE

4 Scan SELECT FLASH OFF TIME SETTING

5 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘5’ ‘1’ and ‘0’ ‘5’ and ‘2’ ‘9’ and ‘9’

6 Scan ENTER/EXIT PROGRAMMING MODE

Scanning Features References

Page 288 of the Solis 842 user manual — Set Length 1
Page 288 · click to enlarge
Page 288

Symbologies

Decoding Levels

Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.

  • Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
  • Choosing Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors.
  • Choosing Level 3, which is the default setting, allows the majority of product labels to be decoded.

There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some bar code labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level.

Set Length

Length Control allows you to select either variable length decoding or fixed length decoding for the specified symbology.

Variable Length: For variable length decoding, a minimum and maximum length may be set.

Fixed Length: For fixed length decoding, two different lengths may be set.

Set Length 1

This feature specifies one of the bar code lengths for a given symbology. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.

Reference the Symbologies section to view the selectable range (number of characters) for the symbology being set.

Follow these instructions to set this feature:

1. Determine the desired character length. Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
3. Scan the “Select Length 1 Setting” for the symbology being set.

References Symbologies

Page 289 of the Solis 842 user manual — STEP ACTION EXAMPLES
Page 289 · click to enlarge
Page 289
4. Scan the appropriate two digits from the keypad in Appendix D, Keypad , that represent the length setting which was determined in the steps above. You will hear a two-beep indica tion after the last character

If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

NOTE

5. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.

This completes the procedure. See the table below for examples of how to set this feature.

Table 21. Length 1 Setting Examples

STEP ACTION EXAMPLES

1 Desired Setting 01 Character 07 Characters 52 Characters 74 Characters

2 Scan ENTER/EXIT PROGRAMMING MODE

3 Scan SELECT LENGTH 1SETTING for the desired symbology

4 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘1’ ‘0’ and ‘7’ ‘5’ and ‘2’ ‘7’ AND ‘4’

5 Scan ENTER/EXIT PROGRAMMING MODE

Symbologies References

Page 290 of the Solis 842 user manual — STEP ACTION EXAMPLES
Page 290 · click to enlarge
Page 290

Set Length 2

This feature specifies one of the bar code lengths for a given symbology. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.

Reference the Symbologies section to view the selectable range (number of characters) for the symbology being set. A setting of 00 specifies to ignore this length (only one fixed length).

Follow these instructions to set this feature:

1. Determine the desired character length. Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
3. Scan the “Select Length 2 Setting” for the symbology being set.
4. Scan the appropriate two digits from the keypad in Appendix D, Keypad , that represent the length setting which was determined in the steps above. You will hear a two-beep indica tion after the last character.

If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.

NOTE

5. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.

This completes the procedure. See the table below for examples of how to set this feature.

Table 22. Length 2 Setting Examples

STEP ACTION EXAMPLES

1 Desired Setting 00 (ignore sec ond length) 07 Characters 52 Characters 74 Characters

2 Scan ENTER/EXIT PROGRAMMING MODE

3 Scan SELECT LENGTH 2 SETTING

4 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘0’ ‘0’ and ‘7’ ‘5’ and ‘2’ ‘7’ and ‘4’

5 Scan ENTER/EXIT PROGRAMMING MODE

References Symbologies

Page 291 of the Solis 842 user manual — Appendix A
Page 291 · click to enlarge
Page 291

Appendix A

Technical Specifications

The table below contains Physical and Performance Characteristics, User Environment and Regulatory information. Table 25 provides Standard Cable Pinouts.

Table 23.

Dimensions Touch 65: 16.0 x 8.4 x 5.8 cm / 6.3 x 3.3 x 2.3 in Touch 90: 17.0 x 10.4 x 6.7 cm / 6.7 x 4.1 x 2.7 in

Weight (without cable) Touch 65130.0 g / 4.6 oz Touch 90: 153.0 g / 5.4 oz

Black; TD1130 (Pro) available in White ; Other colors and custom logo options are available for minimum quantity purchase.

Operating (Typical): < 100 mA @ 5 VDC Standby/Idle (Typical): 20 mA @ 5 VDC Max 180mA @ 5VDC

Input Voltage 5 VDC +/- 0.5 V

Imager Sensor Linear Imaging SensorIllumination: Red LED 640 nm wavelength

Print Contrast Ratio (Minimum) 25%

Roll (Tilt) Tolerance ± 45° from normal

Pitch Tolerance ± 65°

Skew (Yaw) Tolerance ± 70°

Reading Indicators Beeper (Adjustable Tone); Good Read LED

Resolution (1D Codes, Maximum)

Touch 65 Minimum Resolution = 4 mil (0.102 mm) Touch 90 Min Resolution = 5 mil (0.127 mm)

Show 7 more labels / short text on this page
Technical Specifications · Item Description · Physical Characteristics · Color · Electrical Characteristics · Voltage & Current · Reading Performance
Page 292 of the Solis 842 user manual — EMI/RFI
Page 292 · click to enlarge
Page 292

Typical Depth Of Field Minimum distance determined by symbol length and scan angle.

Printing resolution, contrast, and ambient light dependent.

Touch 65 Touch 90

Code 39 5 mils0 to 5.0 cm (1.97 inches) 0-2.5 cm (0.98 inches)
Code 39 7.5 mils0 to 10.0 cm (3.94 inches) 0-8.5 cm (3.35 inches)
Code 39 10 mils0 to 15.0 cm (5.91 inches) 0-13.5 cm (5.31 inches)
EAN-13 13 mils0 to 20.0 cm (7.87 inches) 0-18.5 cm (7.28 inches)

1D / Linear Codes Autodiscriminates all standard 1D codes including GS1 DataBar™ linear codes.

Stacked Codes GS1 DataBar Expanded Stacked; GS1 DataBar Stacked; GS1 DataBar Stacked Omnidirectional

Humidity 5 - 95%

Drop specifications Withstands repeated drops from 1.5 m / 5.0 ft onto a con- crete surface

Ambient Light immunity 0 - 20,000 lux

Particulate and Water Sealing IP30

ESD Level 16 kV

LED Emission Class (IEC-62471:2006-07) Exempt Risk Group (RG 0)

Electrical Safety IEC 60950-1 , CAN/CSA C22.2 No. 60950-1-07; UL 60950-1

North America (FCC) : Part 15 Class B, Canada ( IC) : ICES- 003 Class B, European Union EMC Directive, Australian (C- tick), Russia (Gost); Korean KCC ; Japan (VCCI)

EMI/RFI

Show 5 more labels / short text on this page
Technical Specifications · Reading Ranges · Item Description · Decoding Capability · Regulatory
Page 293 of the Solis 842 user manual — Standard Cable Pinouts
Page 293 · click to enlarge
Page 293

Standard Cable Pinouts

Figure 24 and Table 25 provide standard pinout information for the reader’s cable.

Figure 24. Standard Cable Pinouts

Solis 842 — Standard Cable Pinouts diagram (page 293)
Fig. 346 · Standard Cable Pinouts

The signal descriptions in Table 25 apply to the connector on the reader and are for ref- erence only.

Table 25. Standard Cable Pinouts — Reader Side

Solis 842 — Standard Cable Pinouts diagram (page 293)
Fig. 347 · Standard Cable Pinouts

Standard Cable Pinouts

Page 294 of the Solis 842 user manual — N/A
Page 294 · click to enlarge
Page 294

LED and Beeper Indications

The reader’s beeper sounds and its LED illuminates to indicate various functions or er- rors on the reader. The tables below list these indications. One exception to the behaviors listed in the tables is that the reader’s functions are programmable, and may or may not be turned on. For example, certain indications such as the power-up beep can be disabled using programming bar code labels.

Table 26. LED and Beeper Indications

INDICATION DESCRIPTION LED BEEPER

LED flashes/blinks on power-up but this may be

Reader beeps four times at highest frequency and volume upon power-up.

Power-up Beep The reader is in the process of pow ering-up.

too rapid to view. With a USB interface, the LED blinks

until enumeration with the

host is completed.

LED behavior for this indica tion is configurable via the feature “Good Read: When to Indicate”

The reader will beep once at cur rent frequency, volume, mono/bi- tonal setting and duration upon a successful label scan.

Good Read Beep A label has been successfully scanned by the reader.

ROM Failure There is an error in the reader's software/programming

Flashes 200mS on /

200mS off Reader sounds one error beep at highest volume for 200 mS.

Indicates that a host connection is not established when the USB interface is enabled.

Reader 'chirps' six times at the highest frequency and current vol ume.

Limited Scanning Label Read

N/A

The reader has been disabled by the host.

The LED blinks continuously 100mS on / 900 mS off N/A

Programming Mode - The following indications ONLY occur when the reader is in Programming Mode.

INDICATION DESCRIPTION LED BEEPER

Label Program- ming Mode Entry

A valid programming label has been scanned. LED blinks continuously Reader sounds four low frequency

beeps.

Label Program- ming Mode Rejec- tion of Label

A label has been rejected. N/A Reader sounds three times at low- est frequency & current volume.

In cases where multiple labels must be scanned to program one feature, this indication acknowl- edges each portion as it is success- fully scanned.

Label Program- ming Mode Accep- tance of Partial Label

Reader sounds one short beep at

N/A

highest frequency & current vol-

ume.

Technical Specifications · Reader Disabled

Page 295 of the Solis 842 user manual — NUMBER OF
Page 295 · click to enlarge
Page 295

Programming Mode - The following indications ONLY occur when the reader is in Programming Mode.

INDICATION DESCRIPTION LED BEEPER

Label Program- ming Mode Accep- tance of Programming

Configuration option(s) have been successfully programmed via labels and the reader has exited Programming Mode.

Reader sounds one high frequency beep and 4 low frequency beeps followed by reset beeps.

N/A

Label Program- ming Mode Can- cel Item Entry

Cancel label has been scanned. N/A Reader sounds two times at low frequency and current volume.

Error Codes

Upon startup, if the reader sounds a long tone, this means the reader has not passed its automatic Selftest and has entered FRU (Field Replaceable Unit) isolation mode. If the reader is reset, the sequence will be repeated. The following table describes the LED flashes/beep codes associated with an error found.

NUMBER OF

LED FLASHES/

ERROR CORRECTIVE ACTION

BEEPS

Contact Helpdesk for assistance 2 Interface PCB

Show 4 more labels / short text on this page
Error Codes · 1 Configuration · 5 [Reserved] · 6 Digital PCB
Page 296 of the Solis 842 user manual — NOTES
Page 296 · click to enlarge
Page 296

NOTES

Technical Specifications

Page 297 of the Solis 842 user manual — RS-232/USB-COM
Page 297 · click to enlarge
Page 297

Appendix B

Standard Defaults

The most common configuration settings are listed in the “Default” column of Table 27. The settings in this table are as applied to a standard RS-232 interface. See Table 1 for a listing of default exceptions to this list as applied to other interface types. Page references are also provided for feature descriptions and programming bar codes for each parameter. A column has also been provided for recording of your preferred default settings for these same configurable features.

Table 27. Standard Defaults

Parameter Default Your Setting Page Number

GLOBAL INTERFACE FEATURES

Host Commands — Obey/Ignore Obey 21

USB Suspend Mode Disable 22

RS-232

Baud Rate 9600 19

Data Bits 8 Data Bits 21

Stop Bits 1 Stop Bit 21

Handshaking Control Disable 23

RS-232/USB-COM

Intercharacter Delay No Delay 25

Beep On ASCII BEL Disable 26

Beep On Not on File Enable 26

ACK Character ‘ACK’ 28

NAK Character ‘NAK’ 28

ACK NAK Timeout Value 600 ms 29

ACK NAK Retry Count 3 Retries 30

ACK NAK Error Handling Ignore Errors

Indicate Transmission Failure Enable 32

Parity None 22 · Detected 31

Page 298 of the Solis 842 user manual — DATA FORMAT
Page 298 · click to enlarge
Page 298

Parameter Default Your Setting Page Number

Disable Character ‘D’ 32

Enable Character ‘E’ 33

KEYBOARD WEDGE

Country Mode U.S. Keyboard 35

Caps Lock State Caps Lock OFF 38

Keyboard Numeric Keypad Standard Keys 39

Keyboard Send Control Characters Disable 40

Wedge Quiet Interval 100ms 41

Intercharacter Delay No Delay 42

Intercode Delay 100 ms 43

USB Keyboard Speed 1 ms 44

USB-OEM

USB-OEM Device Usage Handheld Scanner 48

USB-OEM Interface Options Ignore 48

W AND E MULATION

Wand Signal Speed 660ms 49

Quiet Zones & Spaces Low, Bars

Wand Idle State High 50

Transmit Noise Disable 51

Label Symbology Conversion No conversion 52

DATA FORMAT

Global AIM ID Disable 55

GS1-128 AIM ID Enable 55

Label ID Control Disable 57

Set Global Mid Label ID Character(s) No Characters 64

Show 9 more labels / short text on this page
Standard Defaults · Numlock Numlock Key · Unchanged 38 · Wand Polarity · High · No Global Prefix · Global Prefix/Suffix · Global Suffix = · 0x0D (CR) 54
Page 299 of the Solis 842 user manual — EAN 88
Page 299 · click to enlarge
Page 299

Parameter Default Your Setting Page Number

Case Conversion Disable 65

Character Conversion No Char Conversion 66

READING PARAMETERS

Double Read Timeout 0.6 Second 68

Label Gone Timeout 160 ms 70

Power Save Mode Enabled 71

Sleep Mode Timeout Disabled 72

LED AND B EEPER I NDICATIONS

Power On Alert 4 Beeps 73

Good ReadWhen to Indicate After Decode 74

Good Read Beep Type Mono 75

Good Read Beep Frequency Medium 75

Good Read Beep Length 80 ms 77

Illumination Control Illumination Off

Good Read Beep Volume High 76

Good Read LED Duration LED on until next trigger pull 79

SCANNING FEATURES

Scan Mode Trigger Single 80

Stand Mode Triggered Timeout 0.5 Seconds 81

Scanning Active Time 5 Seconds 83

Stand Mode Flash Disable 83

Flash On Time 1 Second 84

Flash Off Time 600 ms 84

Stand Mode Sensitivity Medium 85

SYMBOLOGIES

Coupon Control Enable only UPC/

EAN 88

UPC-A

UPC-A Enable/Disable Enable 89

during beep 78

Page 300 of the Solis 842 user manual — EAN 8
Page 300 · click to enlarge
Page 300

Parameter Default Your Setting Page Number

UPC-A Check Character Transmission Enable 89

Expand UPC-A to EAN-13 Don’t Expand 90

UPC-A Number System Character Trans mission Transmit 90

In-Store Minimum Reads 2 91

UPC-E

UPC-E Enable/Disable Enable 92

UPC-E Check Character Transmission Send 92

Expand UPC-E to EAN-13 Don’t Expand 93

Expand UPC-E to UPC-A Don’t Expand 93

UPC-E Number System Character Trans mission Transmit 94

UPC-E Minimum Read 2 94

EAN 13

EAN 13 Enable/Disable Enable 95

EAN 13 Check Character Transmission Send 95

EAN-13 Flag 1 Character Transmit 96

EAN-13 ISBN Conversion Disable 96

ISSN Enable/Disable Disable 97

EAN 13 Minimum Reads 1 97

EAN 8

EAN 8 Enable/Disable Enable 98

EAN 8 Check Character Transmission Send 98

Expand EAN 8 to EAN 13 Disable 99

EAN 8 Both Guards Substitution Disable 99

EAN 8 Guard Insertion Disable 100

EAN 8 Guard Substitution Disable 100

EAN 8 Minimum Segment Length Block 8 101

EAN 8 Minimum Reads 1 103

EAN 8 Stitch Exact Label Halves Disable 104

EAN 8 Stitch Unlike Label Halves Disable 104

Standard Defaults

Page 301 of the Solis 842 user manual — GS1 D ATA B AR E XPANDED
Page 301 · click to enlarge
Page 301

Parameter Default Your Setting Page Number

EAN T WO L ABEL

EAN Two Label Enable/Disable Disable 105

EAN Two Label Combined Transmission Disable 105

EAN Two Label Minimum Reads 1 Read 106

UPC/EAN G LOBAL S ETTINGS

UPC/EAN Decoding Level 2 107

UPC/EAN Correlation Disable 108

UPC/EAN Price Weight Check Disable 109

UPC-A Minimum Reads 1 Read 110

UPC/EAN Guard Insertion Disable 111

UPC/EAN Stitch Exact Label Halves Disable 111

UPC/EAN Stitch Unlike Label Halves Disable 112

UPC/EAN Minimum Segment Length 5 113

A DD - ONS

Optional Add-ons Disable P2, P5

Optional Add-On Timer 70 ms 117

P2 Add-Ons Minimum Reads 2 119

P5 Add-Ons Minimum Reads 1 120

GS1-128 Add-Ons Minimum Reads 1 121

GS1 D ATA B AR O MNIDIRECTIONAL

GS1 DataBar Omnidirectional Enable/ Disable Disable 122

GS1 DataBar Omnidirectional GS1-128 Emulation Disable 122

GS1 DataBar Omnidirectional Minimum Reads 1 123

GS1 D ATA B AR E XPANDED

GS1 DataBar Expanded Enable/Disable Disable 124

GS1 DataBar Expanded GS1-128 Emula tion Disable 124

GS1 DataBar Expanded Minimum Reads 1 125

and P8 115

Page 302 of the Solis 842 user manual — C ODE 39 CIP
Page 302 · click to enlarge
Page 302

Parameter Default Your Setting Page Number

GS1 DataBar Expanded Length Control Variable 126

GS1 DataBar Expanded Set Length 1 1 126

GS1 DataBar Expanded Set Length 2 74 127

GS1 D ATA B AR L IMITED

GS1 DataBar Limited Enable/Disable Disable 128

GS1 DataBar Limited GS1-128 Emulation Disable 128

GS1 DataBar Limited Minimum Reads 1 129

C ODE 39

Code 39 Enable/Disable Enable 130

Code 39 Check Character Calculation Don’t Calculate 131

Code 39 Check Character Transmission Send 132

Code 39 Start/Stop Character Transmis sion Don’t Transmit 132

Code 39 Full ASCII Disable 133

Code 39 Quiet Zones Auto 134

Code 39 Minimum Reads 2 135

Code 39 Decoding Level 3 136

Code 39 Length Control Variable 137

Code 39 Set Length 1 2 138

Code 39 Set Length 2 50 139

Code 39 Interdigit Ratio 4 140

Code 39 Character Correlation Disable 142

Code 39 Stitching Enable 142

C ODE 32

Code 32 Enable/Disable Disable 143

Code 32 Check Character Transmission Don’t Send 144

Code 32 Start/Stop Character Transmis sion Don’t Transmit 144

C ODE 39 CIP

Code 39 CIP Enable/Disable Disable 145

Standard Defaults

Page 303 of the Solis 842 user manual — D ATALOGIC 2 OF 5
Page 303 · click to enlarge
Page 303

Parameter Default Your Setting Page Number

C ODE 128

Code 128 Enable/Disable Enable 145

Expand Code 128 to Code 39 Don’t Expand 146

Code 128 Check Character Transmission Don’t Send 146

Code 128 Quiet Zones Auto 148

Code 128 Minimum Reads 1 149

Code 128 Decoding Level 3 150

Code 128 Length Control Variable 151

Code 128 Set Length 1 1 152

Code 128 Set Length 2 80 153

Code 128 Character Correlation Disable 154

Code 128 Stitching Enable 154

GS1-128

GS1-128 Enable Transmit in Code 128

I NTERLEAVED 2 OF 5

I 2 of 5 Enable/Disable Disable 156

I 2 of 5 Check Character Calculation Disable 157

I 2 of 5 Check Character Transmission Send 158

I 2 of 5 Minimum Reads 2 167

I 2 of 5 Decoding Level 3 160

I 2 of 5 Length Control Variable 161

I 2 of 5 Set Length 1 6 162

I 2 of 5 Set Length 2 50 163

I 2 of 5 Character Correlation Disable 164

I 2 of 5 Stitching Disable 165

I NTERLEAVED 2 OF 5 CIP

Interleaved 2 of 5 CIP HR Enable/Disable Disable 165

D ATALOGIC 2 OF 5

Datalogic 2 of 5 Enable/Disable Enable 166

Data Format 155

Page 304 of the Solis 842 user manual — ABC C ODABAR
Page 304 · click to enlarge
Page 304

Parameter Default Your Setting Page Number

Datalogic 2 of 5 Check Character Calcu lation Disable 166

Datalogic 2 of 5 Check Character Trans mission Don’t Send 167

Datalogic 2 of 5 Minimum Reads 2 167

Datalogic 2 of 5 Length Control Variable 168

Datalogic 2 of 5 Set Length 1 12 169

Datalogic 2 of 5 Set Length 2 100 170

Datalogic 2 of 5 Interdigit Ratio 4 171

Datalogic 2 of 5 Character Correlation Disable 173

Datalogic 2 of 5 Stitching Disable 173

C ODABAR

Codabar Enable/Disable Disable 174

Codabar Check Character Calculation Don’t Calculate 174

Codabar Check Character Transmission Send 175

Codabar Start/Stop Character Transmis sion Transmit 175

Codabar Start/Stop Character Set abcd/abcd 176

Codabar Start/Stop Character Match Don’t Require Match 177

Codabar Quiet Zones Auto 178

Codabar Minimum Reads 2 179

Codabar Decoding Level 3 180

Codabar Length Control Variable 181

Codabar Set Length 1 3 182

Codabar Set Length 2 50 183

Codabar Interdigit Ratio 4 184

Codabar Character Correlation Disable 186

Codabar Stitching Disable 186

ABC C ODABAR

ABC Codabar Enable/Disable Disable 187

ABC Codabar Concatenation Mode Static 187

Standard Defaults

Page 305 of the Solis 842 user manual — I NDUSTRIAL 2 OF 5
Page 305 · click to enlarge
Page 305

Parameter Default Your Setting Page Number

ABC Codabar Dynamic Concatenation Timeout 200mS 188

ABC Codabar Force Concatenation Disable 188

C ODE 11

Code 11 Enable/Disable Disable 189

Code 11 Check Character Calculation Check C and K 190

Code 11 Check Character Transmission Send 190

Code 11 Minimum Reads 2 191

Code 11 Length Control Variable 192

Code 11 Set Length 1 4 192

Code 11 Set Length 2 50 193

Code 11 Interdigit Ratio 4 194

Code 11 Decoding Level 3 196

Code 11 Character Correlation Disable 197

Code 11 Stitching Disable 197

S TANDARD 2 OF 5

Standard 2 of 5 Enable/Disable Disable 198

Standard 2 of 5 Check Character Calcula tion Disable 198

Standard 2 of 5 Check Character Trans mission Send 199

Standard 2 of 5 Minimum Reads 2 199

Standard 2 of 5 Decoding Level 3 200

Standard 2 of 5 Length Control Variable 200

Standard 2 of 5 Set Length 1 8 201

Standard 2 of 5 Set Length 2 50 202

Standard 2 of 5 Character Correlation Disable 203

Standard 2 of 5 Stitching Disable 203

I NDUSTRIAL 2 OF 5

Industrial 2 of 5 Enable/Disable Disable 204

Industrial 2 of 5 Check Character Calcu lation Disable 204

Page 306 of the Solis 842 user manual — C ODE 93
Page 306 · click to enlarge
Page 306

Parameter Default Your Setting Page Number

Industrial 2 of 5 Check Character Trans mission Enable 205

Industrial 2 of 5 Length Control Variable 205

Industrial 2 of 5 Set Length 1 1 Character 206

Industrial 2 of 5 Set Length 2 50 Characters 207

Industrial 2 of 5 Minimum Reads 1 Read 208

Industrial 2 of 5 Stitching Disable 209

Industrial 2 of 5 Character Correlation Disable 209

IATA

IATA Enable/Disable Disable 210

IATA Check Character Transmission Enable 210

ISBT 128

ISBT 128 Concatenation Disable 211

ISBT 128 Concatenation Mode Static 211

ISBT 128 Dynamic Concatenation Time out 200ms 212

ISBT 128 Force Concatenation Disable 213

ISBT 128 Advanced Concatenation Options Disable 213

MSI

MSI Enable/Disable Disable 214

MSI Check Character Calculation Enable Mod10 214

MSI Check Character Transmission Enable 215

MSI Length Control Variable 215

MSI Set Length 1 1 Character 216

MSI Set Length 2 50 Characters 217

MSI Minimum Reads 4 Reads 218

MSI Decoding Level Level 3 219

C ODE 93

Code 93 Enable/Disable Disable 220

Code 93 Check Character Calculation Disable 220

Standard Defaults

Page 307 of the Solis 842 user manual — F OLLETT 2 OF 5
Page 307 · click to enlarge
Page 307

Parameter Default Your Setting Page Number

Code 93 Check Character Transmission Enable 221

Code 93 Length Control Variable 221

Code 93 Set Length 1 1 Character 222

Code 93 Set Length 2 50 Characters 223

Code 93 Minimum Reads 1 Read 224

Code 93 Decoding Level Level 3 225

Code 93 Quiet Zones Auto 226

Code 93 Stitching Enable 227

Code 93 Character Correlation Enable 227

C ODABLOCK F

Codablock F Enable/Disable Disable 228

Codablock F EAN Enable/Disable Disable 228

Codablock F AIM Check Enable Check C 229

Codablock F Length Control Variable 229

Codablock F Set Length 1 3 Characters 230

Codablock F Set Length 2 100 Characters 231

C ODE 4

Code 4 Enable/Disable Disable 232

Code 4 Check Character Transmission Enable 232

Code 4 Hex to Decimal Conversion Enable 233

C ODE 5

Code 5 Enable/Disable Disable 233

Code 5 Check Character Transmission Enable 234

Code 5 Hex to Decimal Conversion Enable 234

CODE 4 AND CODE 5 COMMON CONFIGURATION ITEMS

Code 4 and 5 Decoding Level 3 235

Code 4 and Code 5 Minimum Reads 1 236

F OLLETT 2 OF 5

Follett 2 of 5 Enable/Disable Disable 237

Page 308 of the Solis 842 user manual — Default Exceptions
Page 308 · click to enlarge
Page 308

Parameter Default Your Setting Page Number

BC412

BC412 Enable/Disable Disable 237

BC412 Check Character Calculation Don’t Calculate 238

BC412 Minimum Reads 2 Reads 238

BC412 Decoding Level 3 239

BC412 Length Control Variable Length 240

BC412 Set Length 1 1 Character 240

BC412 Set Length 2 50 Characters 241

P LESSEY

Plessey Enable/Disable Disable 242

Enable Plessey std.

Plessey Check Character Calculation

check char. verification

Plessey Check Character Transmission Enable 244

Plessey Length Control Variable Length 244

Plessey Set Length 1 1 Character 245

Plessey Set Length 2 50 Characters 246

Plessey Minimum Reads 4 247

Plessey Decoding Level 3 248

Plessey Stitching Disable 249

Plessey Character Correlation Disable 249

Default Exceptions

Table 1. Default Exceptions by Interface Type

InterfacesUSB-OEM

Global Suffix No Global Suffix

Double Read Timeout 500 msec

InterfacesAll Keyboard Wedge, USB Keyboard
InterfaceRS232-WN

Standard Defaults · Parameter Default Exception · No unique settings

Page 309 of the Solis 842 user manual — Default Exceptions
Page 309 · click to enlarge
Page 309

Expand UPC-A to EAN-13 Enable

UPC-E Check Character Transmission Disable

Transmission Label ID Code Prefix

GS1-128 AIM ID Disable

UPCE Label ID Character(s) C

EAN 8 Label ID Character(s) B

EAN 13 Label ID Character(s) A

Code ISBN Label ID Character(s) A

Code 39 Label ID Character(s) M

Interleaved 2of5 Label ID Character(s) I

Code Standard 2/5 Label ID Character(s) H

Codabar Label ID Character(s) N

Code 128 Label ID Character(s) K

GS1-128 Label ID Character(s) P

Datalogic 2 of 5 Label ID Character(s) H

ISBT 128 Label ID Character(s) K

UPCE P2 Label ID Character(s) C

UPCE/P5 Label ID Character(s) C

UPCE/GS1-128 Label ID Character(s) C

EAN8/P2 Label ID Character(s) B

EAN8/P5 Label ID Character(s) B

EAN8/GS1-128 Label ID Character(s) B

EAN13/P2 Label ID Character(s) A

EAN13/P5 Label ID Character(s) A

EAN13/GS1-128 Label ID Character(s) A

GS1 DataBar 14 (Omnidirectional) Label ID Character(s) E

GS1 DataBar Expanded Label ID Character(s) E

GS1 DataBar Limited Label ID Character(s) E

Character Conversion CR to `

Show 4 more labels / short text on this page
Default Exceptions · Parameter Default Exception · Parity Odd Parity · Handshaking Control RTS/CTS
Page 310 of the Solis 842 user manual — Default Exceptions
Page 310 · click to enlarge
Page 310
InterfaceRS232-OPOS

Baud Rate 115200 Baud

Transmission Label ID Code Prefix

GS1-128 AIM ID Disable

UPCA Label ID Character(s) C

UPCE Label ID Character(s) D

EAN 8 Label ID Character(s) A

EAN 13 Label ID Character(s) B

Code ISBN Label ID Character(s) @

Code 39 Label ID Character(s) V

Code 32 Label ID Character(s) X

Interleaved 2of5 Label ID Character(s) N

Code Standard 2/5 Label ID Character(s) P

Codabar Label ID Character(s) R

Code 11 Label ID Character(s) b

Code 128 Label ID Character(s) T

GS1-128 Label ID Character(s) k

UPCA/P2 Label ID Character(s) F

UPCA/P5 Label ID Character(s) G

UPCA/GS1-128 Label ID Character(s) Q

UPCE P2 Label ID Character(s) H

UPCE/P5 Label ID Character(s) I

EAN8/P2 Label ID Character(s) J

EAN8/P5 Label ID Character(s) K

EAN8/GS1-128 Label ID Character(s) *

EAN13/P2 Label ID Character(s) L

EAN13/P5 Label ID Character(s) M

EAN13/GS1-128 Label ID Character(s) #

GS1 DataBar 14 (Omnidirectional) Label ID Character(s) u

GS1 DataBar Expanded Label ID Character(s) t

GS1 DataBar Limited Label ID Character(s) v

Standard Defaults · Parameter Default Exception

Page 311 of the Solis 842 user manual — EAN-13
Page 311 · click to enlarge
Page 311

Appendix C

Sample Bar Codes

The sample bar codes in this appendix are typical representations for their symbology types.

1D Bar Codes

UPC-A

0 12345 67890 5

EAN-13

Code 39

123ABC

Code 128

1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4

3 456789 012340

Page 312 of the Solis 842 user manual — Code 11
Page 312 · click to enlarge
Page 312

Interleaved 2 of 5

Code 32

Codabar

Solis 842 — Interleaved 2 of 5 diagram (page 312)
Fig. 348 · Interleaved 2 of 5

Code 93

Solis 842 — Code 93 diagram (page 312)
Fig. 349 · Code 93

Code 11

Solis 842 — Code 11 diagram (page 312)
Fig. 350 · Code 11

Sample Bar Codes · 12345678901231

Page 313 of the Solis 842 user manual — GS1 DataBar-14
Page 313 · click to enlarge
Page 313

GS1 DataBar (RSS)

GS1 DataBar variants must be enabled to read the bar codes below (see GS1 DataBar (RSS) on page 303).

NOTE

Solis 842 — NOTE diagram (page 313)
Fig. 351

10293847560192837465019283746029478450366523 (GS1 DataBar Expanded Stacked)

Solis 842 — NOTE diagram (page 313)
Fig. 352

1234890hjio9900mnb (GS1 DataBar Expanded)

08672345650916 (GS1 DataBar Limited)

GS1 DataBar-14

55432198673467 (GS1 DataBar Omnidirectional Truncated)

90876523412674 (GS1 DataBar Omnidirectional Stacked)

78123465709811 (GS1 DataBar Omnidirectional Stacked)

GS1 DataBar (RSS)

Page 314 of the Solis 842 user manual — NOTES
Page 314 · click to enlarge
Page 314

NOTES

Sample Bar Codes

Page 315 of the Solis 842 user manual — Appendix D
Page 315 · click to enlarge
Page 315

Appendix D

Keypad

Use the bar codes in this appendix to enter numbers as you would select digits/characters from a keypad.

Solis 842 — Appendix D diagram (page 315)
Fig. 353 · Appendix D
Page 316 of the Solis 842 user manual — Keypad
Page 316 · click to enlarge
Page 316
Solis 842 — Keypad diagram (page 316)
Fig. 354 · Keypad

Keypad

Page 317 of the Solis 842 user manual — D
Page 317 · click to enlarge
Page 317

D

E

F

Page 318 of the Solis 842 user manual — NOTES
Page 318 · click to enlarge
Page 318

NOTES

Keypad

Page 319 of the Solis 842 user manual — Control Character Emulation
Page 319 · click to enlarge
Page 319

Appendix E

Scancode Tables

Control Character Emulation

Control character emulation selects from different scancode tables as listed in this appendix. Each of the control character sets below are detailed by interface type in the tables. These apply to Wedge and USB Keyboard platforms.

Control Character 00 — Characters from 00 to 0x1F are sent as control character Ctrl+Keys, special keys are located from 0x80 to 0xA1.

Control Character 01 — Characters from 00 to 0x1F are sent as control character Ctrl+Cap- ital Key, special keys are located from 0x80 to 0xA1.

Control Character 02 — Special keys are located from 00 to 0x1F and characters from 0x80 to 0xFE are intended as an extended ASCII table (Microsoft Windows Codepage 1252 — see page 316).

Page 320 of the Solis 842 user manual — C(S)+B
Page 320 · click to enlarge
Page 320
Solis 842 — Interface Type PC AT PS/2 or USB-Keyboard diagram (page 320)
Fig. 355 · Interface Type PC AT PS/2 or USB-Keyboard
Solis 842 — Interface Type PC AT PS/2 or USB-Keyboard diagram (page 320)
Fig. 356 · Interface Type PC AT PS/2 or USB-Keyboard

7x p q r s t u v w x y z { | } ~ Del

F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11

x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE xF

2x SP ! " # $ % & ' ( ) * + , - . /

3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ?

4x @ A B C D E F G H I J K L M N O

5x P Q R S T U V W X Y Z [ \ ] ^ _

6x ` a b c d e f g h i j k l m n o

Ax Cr _ ‘ ƒ „ … † ‡ ˆ ‰ Š ‹ Ś ‹ Œ _

Bx ° ± ² ³ ´ µ ¶ · ¸ ¹ º » ¼ ½ ¾ ¿

Cx À Á Â Ã Ä Å Æ Ç È É Ê Ë Ì Í Î Ï

Dx Ð _ Ò Ó Ô Õ Ö × Ø Ù Ú Û Ü Ý Þ ß

Ex à á â ã ä å æ ç è é ê ë ì í î ï

Fx ð ñ ò ó ô õ ö ÷ ø ù ú û ü ý þ ÿ

Extended characters (sky blue) are sent via dedicated keys (when available in the selected country mode) or by an Alt Mode sequence.

Table 28. Scancode Set When Control Character is 00 or 01

Interface Type PC AT PS/2 or USB-Keyboard

8x _ Sh Sh Ins Ent

9x F12 Home End Pg Up Pg

C(S)+B

C(S)+R

STX

DC2

C(S)+Q

C(S)+A

SOH

DC1

C(S)+@

C(S)+P

0x NULL · 1x DLE

Page 321 of the Solis 842 user manual — Interface Type PC AT PS/2 or USB-Keyboard
Page 321 · click to enlarge
Page 321
Solis 842 — Interface Type PC AT PS/2 or USB-Keyboard diagram (page 321)
Fig. 357 · Interface Type PC AT PS/2 or USB-Keyboard
Solis 842 — Interface Type PC AT PS/2 or USB-Keyboard diagram (page 321)
Fig. 358 · Interface Type PC AT PS/2 or USB-Keyboard

7x p q r s t u v w x y z { | } ~ Del

x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE xF

Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10

2x Space ! “ # $ % & ‘ ( ) * + , - . /

3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ?

4x @ A B C D E F G H I J K L M N O

5x P Q R S T U V W X Y Z [ \ ] ^ _

6x ` a b c d e f g h i j k l m n o

8x _ _ ‘ ƒ „ … † ‡ ˆ ‰ Š ‹ Ś ‹ Œ _

9x _ ‘ ’ “ ” • – — ˜ ™ š › œ _ _ Ÿ

Ax NBSP ¡ ¢ £ ¤ ¥ ¦ § ¨ © ª « ¬ - ® ¯

Bx ° ± ² ³ ´ µ ¶ · ¸ ¹ º » ¼ ½ ¾ ¿

Cx À Á Â Ã Ä Å Æ Ç È É Ê Ë Ì Í Î Ï

Dx Ð _ Ò Ó Ô Õ Ö × Ø Ù Ú Û Ü Ý Þ ß

Ex à á â ã ä å æ ç è é ê ë ì í î ï

Fx ð ñ ò ó ô õ ö ÷ ø ù ú û ü ý þ ÿ

0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S+ Tab Enter

Interface Type PC AT PS/2 or USB-Keyboard — cont.

Table 29. Scancode Set When Control Character is 02

1x Pg

Page 322 of the Solis 842 user manual — Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode
Page 322 · click to enlarge
Page 322
Solis 842 — Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode diagram (page 322)
Fig. 359 · Interface type PC AT PS/2 Alt Mode or USB-Keyboard A…

2x A+032 A+033 A+034 A+035 A+036 A+037 A+038 A+039 A+040 A+041 A+042 A+043 A+044 A+045 A+046 A+047

3x A+048 A+049 A+050 A+051 A+052 A+053 A+054 A+055 A+056 A+057 A+058 A+059 A+060 A+061 A+062 A+063

4x A+064 A+065 A+066 A+067 A+068 A+069 A+070 A+071 A+072 A+073 A+074 A+075 A+076 A+077 A+078 A+079

5x A+080 A+081 A+082 A+083 A+084 A+085 A+086 A+087 A+088 A+089 A+090 A+091 A+092 A+093 A+094 A+095

Ax Cr A+0161 A+0162 A+0163 A+0164 A+0165 A+0166 A+0167 A+0168 A+0169 A+0170 A+0171 A+0172 A+0173 A+0174 A+0175

Bx A+0176 A+0177 A+0178 A+0179 A+0180 A+0181 A+0182 A+0183 A+0184 A+0185 A+0186 A+0187 A+0188 A+0189 A+0190 A+0191

Cx A+0192 A+0193 A+0194 A+0195 A+0196 A+0197 A+0198 A+0199 A+0200 A+0201 A+0202 A+0203 A+0204 A+0205 A+0206 A+0207

Dx A+0208 A+0209 A+0210 A+0211 A+0212 A+0213 A+0214 A+0215 A+0216 A+0217 A+0218 A+0219 A+0220 A+0221 A+0222 A+0223

Ex A+0224 A+0225 A+0226 A+0227 A+0228 A+0229 A+0230 A+0231 A+0232 A+0233 A+0234 A+0235 A+0236 A+0237 A+0238 A+0239

Fx A+0240 A+0241 A+0242 A+0243 A+0244 A+0245 A+0246 A+0247 A+0248 A+0249 A+0250 A+0251 A+052 A+0253 A+0254 A+0255

6x A+096 A+097 A+098 A+099 A+100 A+101 A+102 A+103 A+104 A+105 A+106 A+107 A+108 A+109 A+110 A+111

7x A+112 A+113 A+114 A+115 A+116 A+117 A+118 A+119 A+120 A+121 A+122 A+123 A+124 A+125 A+126 A+127

F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11

9x F12 Home End Pg Up Pg Dwn Ar Ar Al Al Cl Cl Cr

x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE Xf

1x Alt+016 Alt+017 Alt+018 Alt+019 Alt+020 Alt+021 Alt+022 Alt+023 Alt+024 Alt+025 Alt+026 ESC

0x Alt+000 Alt+001 Alt+002 Alt+003 Alt+004 Alt+005 Alt+006 Alt+007 Alt+008 HT

Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode

Table 30. Scancode Set When Control Character is 00 or 01

8x _ Sh Sh? Ins Ent

(keyp)

Page 323 of the Solis 842 user manual — Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode
Page 323 · click to enlarge
Page 323
Solis 842 — Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode diagram (page 323)
Fig. 360 · Interface type PC AT PS/2 Alt Mode or USB-Keyboard A…

2x A+032 A+033 A+034 A+035 A+036 A+037 A+038 A+039 A+040 A+041 A+042 A+043 A+044 A+045 A+046 A+047

3x A+048 A+049 A+050 A+051 A+052 A+053 A+054 A+055 A+056 A+057 A+058 A+059 A+060 A+061 A+062 A+063

4x A+064 A+065 A+066 A+067 A+068 A+069 A+070 A+071 A+072 A+073 A+074 A+075 A+076 A+077 A+078 A+079

5x A+080 A+081 A+082 A+083 A+084 A+085 A+086 A+087 A+088 A+089 A+090 A+091 A+092 A+093 A+094 A+095

8x A+0128 A+0129 A+0130 A+0131 A+0132 A+0133 A+0134 A+0135 A+0136 A+0137 A+0138 A+0139 A+0140 A+0141 A+0142 A+0143

9x A+0144 A+0145 A+0146 A+0147 A+0148 A+0149 A+0150 A+0151 A+0152 A+0153 A+0154 A+0155 A+0156 A+0157 A+0158 A+0159

Ax A+0160 A+0161 A+0162 A+0163 A+0164 A+0165 A+0166 A+0167 A+0168 A+0169 A+0170 A+0171 A+0172 A+0173 A+0174 A+0175

Bx A+0176 A+0177 A+0178 A+0179 A+0180 A+0181 A+0182 A+0183 A+0184 A+0185 A+0186 A+0187 A+0188 A+0189 A+0190 A+0191

Cx A+0192 A+0193 A+0194 A+0195 A+0196 A+0197 A+0198 A+0199 A+0200 A+0201 A+0202 A+0203 A+0204 A+0205 A+0206 A+0207

Dx A+0208 A+0209 A+0210 A+0211 A+0212 A+0213 A+0214 A+0215 A+0216 A+0217 A+0218 A+0219 A+0220 A+0221 A+0222 A+0223

Ex A+0224 A+0225 A+0226 A+0227 A+0228 A+0229 A+0230 A+0231 A+0232 A+0233 A+0234 A+0235 A+0236 A+0237 A+0238 A+0239

Fx A+0240 A+0241 A+0242 A+0243 A+0244 A+0245 A+0246 A+0247 A+0248 A+0249 A+0250 A+0251 A+052 A+0253 A+0254 A+0255

6x A+096 A+097 A+098 A+099 A+100 A+101 A+102 A+103 A+104 A+105 A+106 A+107 A+108 A+109 A+110 A+111

7x A+112 A+113 A+114 A+115 A+116 A+117 A+118 A+119 A+120 A+121 A+122 A+123 A+124 A+125 A+126 A+127

x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE xF

Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10

0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S+ Tab Enter

Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode — cont.

Table 31. Scancode Set When Control Character is 02

1x Pg

Page 324 of the Solis 842 user manual — EOT
Page 324 · click to enlarge
Page 324

C(S)+O

C(S)+_

7x p q r s t u v w x y z { | } ~ Del

F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11

X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF

2x Space ! “ # $ % & ‘ ( ) * + , - . /

3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ?

4x @ A B C D E F G H I J K L M N O

5x P Q R S T U V W X Y Z [ \ ] ^ _

6x ` a b c d e f g h i j k l m n o

US

SI

C(S)+N

C(S)+^

9x F12 F13 F14 F15 F16 Cl Cl

SO

RS

CR

GS

C+]

C(S)+L

C(S)+\

FF

FS

C(S)+K

ESC

VT

C(S)+J

C(S)+Z

SUB

LF

C(S)+Y

TAB

EM

HT

C(S)+H

C(S)+X

CAN

BS

Table 32. Scancode Set When Control Character is 00 or 01

C(S)+G

C(S)+W

BEL

ETB

C(S)+F

C(S)+V

ACK

SYN

C(S)+E

C(S)+U

ENQ

NAK

C(S)+T

8x Sh Sh Ins Ent

EOT

C+D

DC4

C(S)+C

C(S)+S

ETX

DC3

C(S)+B

C(S)+R

STX

DC2

C(S)+Q

C(S)+A

SOH

DC1

Digital Interface

C(S)+@

C(S)+P

Show 5 more labels / short text on this page
Enter · Esc · (keyp) · 0x NULL · 1x DLE
Page 325 of the Solis 842 user manual — Digital Interface
Page 325 · click to enlarge
Page 325

7x p q r s t u v w x y z { | } ~ Del

X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF

1x F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10

2x Space ! “ # $ % & ‘ ( ) * + , - . /

3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ?

4x @ A B C D E F G H I J K L M N O

5x P Q R S T U V W X Y Z [ \ ] ^ _

6x ` a b c d e f g h i j k l m n o

0x Cl Cl BS Tab S+ Tab Enter

Table 33. Scancode Set When Control Character is 02

Digital Interface — cont.

Keypd Enter Ins

Page 326 of the Solis 842 user manual — EOT
Page 326 · click to enlarge
Page 326

C(S)+O

C(S)+_

7x p q R s t u v w x y z { | } Del

F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11

Dwn Ar Ar Al Al Cl Cl Cr

X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF

2x Space ! “ # $ % & ‘ ( ) * + , - . /

3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ?

4x @ A B C D E F G H I J K L M N O

5x P Q R S T U V W X Y Z [ \ ] ^ _

6x ‘ a B c d e f g h i j k l m n o

US

SI

C(S)+N

C(S)+^

SO

RS

CR

GS

C+]

C(S)+L

C(S)+\

FF

FS

C(S)+K

ESC

VT

C(S)+J

C(S)+Z

SUB

LF

C(S)+Y

TAB

EM

HT

C(S)+H

C(S)+X

CAN

BS

Table 34. Scancode Set When Control Character is 00 or 01

C(S)+G

C(S)+W

BEL

ETB

C(S)+F

C(S)+V

ACK

SYN

C(S)+E

C(S)+U

ENQ

NAK

C(S)+T

8x Sh? Sh? Ins Ent

9x F12 Home End Pg Up Pg

EOT

C+D

DC4

C(S)+C

C(S)+S

ETX

DC3

C(S)+B

C(S)+R

STX

DC2

C(S)+Q

C(S)+A

SOH

DC1

C(S)+@

C(S)+P

IBM XT

Show 6 more labels / short text on this page
Enter · Esc · (keyp) · Ax Cr · 0x NULL · 1x DLE
Page 327 of the Solis 842 user manual — IBM XT
Page 327 · click to enlarge
Page 327

Keypd Enter Ins Pg Up

7x p q R s t u v w x y z { | } Del

X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF

Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10

2x Space ! “ # $ % & ‘ ( ) * + , - . /

3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ?

4x @ A B C D E F G H I J K L M N O

5x P Q R S T U V W X Y Z [ \ ] ^ _

6x ‘ a B c d e f g h i j k l m n o

0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S+ Tab Enter

Table 35. Scancode Set When Control Character is 02

IBM XT — cont.

1x Pg

Page 328 of the Solis 842 user manual — Microsoft Windows Codepage 1252
Page 328 · click to enlarge
Page 328

Microsoft Windows Codepage 1252

Windows-1252 is a character encoding of the Latin alphabet, used by default in the legacy com- ponents of Microsoft Windows in English and some other Western languages.

Solis 842 — Microsoft Windows Codepage 1252 diagram (page 328)
Fig. 361 · Microsoft Windows Codepage 1252

Scancode Tables

Page 329 of the Solis 842 user manual — Table of contents
Page 329 · click to enlarge
Page 329

Table of contents

Introductionp.11About the Touch TD1100p.11About this Manualp.11Overviewp.11Conventionsp.12Technical Supportp.12Datalogic Website Supportp.12Reseller Technical Supportp.12Telephone Technical Supportp.13Setupp.15Unpackingp.15Setting Up the Readerp.15Install the Interface Cablep.15Connect Host Interfacep.17Holder/Hands-Free Standp.18Interface Selectionp.19Configuring the Interfacep.19Customizing Configuration Settingsp.22Using the Programming Bar Codesp.22Interface Settingsp.23Configuring Other Featuresp.23Software Version Transmissionp.23Configuration Using Bar Codesp.25Configuration Parametersp.25Host Commands — Obey/Ignorep.27USB Suspend Modep.28RS-232 Only Interfacep.29RS-232 Standard Factory Settingsp.29Baud Ratep.29Data Bitsp.31Stop Bitsp.31Parityp.32Handshaking Controlp.33RS-232/USB-Com Interfacesp.35Standard Factory Settingsp.35Intercharacter Delayp.35Beep On ASCII BELp.36Beep On Not on Filep.36ACK NAK Optionsp.37ACK Characterp.38NAK Characterp.38ACK NAK Timeout Valuep.39ACK NAK Retry Countp.40ACK NAK Error Handlingp.41Indicate Transmission Failurep.42Disable Characterp.42Enable Characterp.43Keyboard Interfacep.45Country Modep.45Caps Lock Statep.48Numlockp.48Keyboard Numeric Keypadp.49Keyboard Send Control Charactersp.50Wedge Quiet Intervalp.51Intercharacter Delayp.52Intercode Delayp.53USB Keyboard Speedp.54USB-OEM Interfacep.57Introductionp.57Standard Factory Settingsp.57USB-OEM Device Usagep.58USB-OEM Interface Optionsp.58Wand Emulation Interfacep.59Wand Signal Speedp.59Wand Polarityp.60Wand Idle Statep.60Transmit Noisep.61Label Symbology Conversionp.62Data Formatp.63Global Prefix/Suffixp.64Global AIM IDp.65GS1-128 AIM IDp.65Label IDp.66Label ID: Pre-loaded Setsp.66Label ID: Set Individually Per Symbologyp.67Label ID Controlp.67Label ID Symbology Selectionp.68Set Global Mid Label ID Character(s)p.74Case Conversionp.75Character Conversionp.76Reading Parametersp.77Double Read Timeoutp.78Label Gone Timeoutp.80Power Save Modep.81Sleep Mode Timeoutp.82LED and Beeper Indicatorsp.83Power On Alertp.83Good Read: When to Indicatep.84Good Read Beep Typep.85Good Read Beep Frequencyp.85Good Read Beep Volumep.86Good Read Beep Lengthp.87Illumination Controlp.88Good Read LED Durationp.89Scanning Featuresp.90Scan Modep.90Stand Mode Triggered Timeoutp.91Scanning Active Timep.93Stand Mode Flashp.93Flash On Timep.94Flash Off Timep.94Stand Mode Sensitivityp.95Symbologiesp.97Introductionp.97Standard Factory Settings for Symbologiesp.97Disable All Symbologiesp.98Coupon Controlp.98UPC-Ap.99UPC-A Enable/Disablep.99UPC-A Check Character Transmissionp.99Expand UPC-A to EAN-13p.100UPC-A Number System Character Transmissionp.100In-Store Minimum Readsp.101UPC-Ep.102UPC-E Enable/Disablep.102UPC-E Check Character Transmissionp.102Expand UPC-E to EAN-13p.103Expand UPC-E to UPC-Ap.103UPC-E Number System Character Transmissionp.104UPC-E Minimum Readp.104EAN 13p.105EAN 13 Enable/Disablep.105EAN 13 Check Character Transmissionp.105EAN-13 Flag 1 Characterp.106EAN-13 ISBN Conversionp.106ISSN Enable/Disablep.107EAN 13 Minimum Readsp.107EAN 8p.108EAN 8 Enable/Disablep.108EAN 8 Check Character Transmissionp.108Expand EAN 8 to EAN 13p.109EAN 8 Both Guards Substitutionp.109EAN 8 Guard Insertionp.110EAN 8 Guard Substitutionp.110EAN 8 Minimum Segment Length Blockp.111EAN 8 Minimum Readsp.113EAN 8 Stitch Exact Label Halvesp.114EAN 8 Stitch Unlike Label Halvesp.114EAN Two Labelp.115EAN Two Label Enable/Disablep.115EAN Two Label Combined Transmissionp.115EAN Two Label Minimum Readsp.116UPC/EAN Global Settingsp.117UPC/EAN Decoding Levelp.117UPC/EAN Correlationp.118UPC/EAN Price Weight Checkp.119UPC-A Minimum Readsp.120UPC/EAN Guard Insertionp.121UPC/EAN Stitch Exact Label Halvesp.121UPC/EAN Stitch Unlike Label Halvesp.122UPC/EAN Minimum Segment Lengthp.123Add-Onsp.125Optional Add-onsp.125Optional Add-On Timerp.127P2 Add-Ons Minimum Readsp.129P5 Add-Ons Minimum Readsp.130GS1-128 Add-Ons Minimum Readsp.131GS1 DataBarTM Omnidirectionalp.132GS1 DataBar Omnidirectional Enable/Disablep.132GS1 DataBar Omnidirectional GS1-128 Emulationp.132GS1 DataBar Omnidirectional Minimum Readsp.133GS1 DataBarTM Expandedp.134GS1 DataBar Expanded Enable/Disablep.134GS1 DataBar Expanded GS1-128 Emulationp.134GS1 DataBar Expanded Minimum Readsp.135GS1 DataBar Expanded Length Controlp.136GS1 DataBar Expanded Set Length 1p.136GS1 DataBar Expanded Set Length 2p.137GS1 DataBarTM Limitedp.138GS1 DataBar Limited Enable/Disablep.138GS1 DataBar Limited GS1-128 Emulationp.138GS1 DataBar Limited Minimum Readsp.139Code 39p.140Code 39 Enable/Disablep.140Code 39 Check Character Calculationp.141Code 39 Check Character Transmissionp.142Code 39 Start/Stop Character Transmissionp.142Code 39 Full ASCIIp.143Code 39 Quiet Zonesp.144Code 39 Minimum Readsp.145Code 39 Decoding Levelp.146Code 39 Length Controlp.147Code 39 Set Length 1p.148Code 39 Set Length 2p.149Code 39 Interdigit Ratiop.150Code 39 Character Correlationp.152Code 39 Stitchingp.152Code 32 (Italian Pharmaceutical)p.153Code 32 Enable/Disablep.153Code 32 Feature Setting Exceptionsp.153Code 32 Check Character Transmissionp.154Code 32 Start/Stop Character Transmissionp.154Code 39 CIP (French Pharmaceutical)p.155Code 39 CIP Enable/Disablep.155Code 128p.155Code 128 Enable/Disablep.155Expand Code 128 to Code 39p.156Code 128 Check Character Transmissionp.156Code 128 Function Character Transmissionp.157Code 128 Sub-Code Change Transmissionp.157Code 128 Quiet Zonesp.158Code 128 Minimum Readsp.159Code 128 Decoding Levelp.160Code 128 Length Controlp.161Code 128 Set Length 1p.162Code 128 Set Length 2p.163Code 128 Character Correlationp.164Code 128 Stitchingp.164GS1-128p.165GS1-128 Enablep.165Interleaved 2 of 5 (I 2 of 5)p.166I 2 of 5 Enable/Disablep.166I 2 of 5 Check Character Calculationp.167I 2 of 5 Check Character Transmissionp.168I 2 of 5 Minimum Readsp.169I 2 of 5 Decoding Levelp.170I 2 of 5 Length Controlp.171I 2 of 5 Set Length 1p.172I 2 of 5 Set Length 2p.173I 2 of 5 Character Correlationp.174I 2 of 5 Zero Patternp.174I 2 of 5 Stitchingp.175Interleaved 2 of 5 CIP HRp.175Interleaved 2 of 5 CIP HR Enable/Disablep.175Datalogic 2 of 5p.176Datalogic 2 of 5 Enable/Disablep.176Datalogic 2 of 5 Check Character Calculationp.176Datalogic 2 of 5 Check Character Transmissionp.177Datalogic 2 of 5 Minimum Readsp.177Datalogic 2 of 5 Decoding Levelp.178Datalogic 2 of 5 Length Controlp.178Datalogic 2 of 5 Set Length 1p.179Datalogic 2 of 5 Set Length 2p.180Datalogic 2 of 5 Interdigit Ratiop.181Datalogic 2 of 5 Character Correlationp.183Datalogic 2 of 5 Stitchingp.183Codabarp.184Codabar Enable/Disablep.184Codabar Check Character Calculationp.184Codabar Check Character Transmissionp.185Codabar Start/Stop Character Transmissionp.185Codabar Start/Stop Character Setp.186Codabar Start/Stop Character Matchp.187Codabar Quiet Zonesp.188Codabar Minimum Readsp.189Codabar Decoding Levelp.190Codabar Length Controlp.191Codabar Set Length 1p.192Codabar Set Length 2p.193Codabar Interdigit Ratiop.194Codabar Character Correlationp.196Codabar Stitchingp.196ABC Codabarp.197ABC Codabar Enable/Disablep.197ABC Codabar Concatenation Modep.197ABC Codabar Dynamic Concatenation Timeoutp.198ABC Codabar Force Concatenationp.198Code 11p.199Code 11 Enable/Disablep.199Code 11 Check Character Calculationp.200Code 11 Check Character Transmissionp.200Code 11 Minimum Readsp.201Code 11 Length Controlp.202Code 11 Set Length 1p.202Code 11 Set Length 2p.203Code 11 Interdigit Ratiop.204Code 11 Decoding Levelp.206Code 11 Character Correlationp.207Code 11 Stitchingp.207Standard 2 of 5p.208Standard 2 of 5 Enable/Disablep.208Standard 2 of 5 Check Character Calculationp.208Standard 2 of 5 Check Character Transmissionp.209Standard 2 of 5 Minimum Readsp.209Standard 2 of 5 Decoding Levelp.210Standard 2 of 5 Length Controlp.210Standard 2 of 5 Set Length 1p.211Standard 2 of 5 Set Length 2p.212Standard 2 of 5 Character Correlationp.213Standard 2 of 5 Stitchingp.213Industrial 2 of 5p.214Industrial 2 of 5 Enable/Disablep.214Industrial 2 of 5 Check Character Calculationp.214Industrial 2 of 5 Check Character Transmissionp.215Industrial 2 of 5 Length Controlp.215Industrial 2 of 5 Set Length 1p.216Industrial 2 of 5 Set Length 2p.217Industrial 2 of 5 Minimum Readsp.218Industrial 2 of 5 Stitchingp.219Industrial 2 of 5 Character Correlationp.219IATAp.220IATA Enable/Disablep.220IATA Check Character Transmissionp.220ISBT 128p.221ISBT 128 Concatenationp.221ISBT 128 Concatenation Modep.221ISBT 128 Dynamic Concatenation Timeoutp.222ISBT 128 Force Concatenationp.223ISBT 128 Advanced Concatenation Optionsp.223MSIp.224MSI Enable/Disablep.224MSI Check Character Calculationp.224MSI Check Character Transmissionp.225MSI Length Controlp.225MSI Set Length 1p.226MSI Set Length 2p.227MSI Minimum Readsp.228MSI Decoding Levelp.229Code 93p.230Code 93 Enable/Disablep.230Code 93 Check Character Calculationp.230Code 93 Check Character Transmissionp.231Code 93 Length Controlp.231Code 93 Set Length 1p.232Code 93 Set Length 2p.233Code 93 Minimum Readsp.234Code 93 Decoding Levelp.235Code 93 Quiet Zonesp.236Code 93 Stitchingp.237Code 93 Character Correlationp.237Codablock Fp.238Codablock F Enable/Disablep.238Codablock F EAN Enable/Disablep.238Codablock F AIM Checkp.239Codablock F Length Controlp.239Codablock F Set Length 1p.240Codablock F Set Length 2p.241Code 4p.242Code 4 Enable/Disablep.242Code 4 Check Character Transmissionp.242Code 4 Hex to Decimal Conversionp.243Code 5p.243Code 5 Enable/Disablep.243Code 5 Check Character Transmissionp.244Code 5 Hex to Decimal Conversionp.244Code 4 and Code 5 Common Configuration Itemsp.245Code 4 and 5 Decoding Levelp.245Code 4 and Code 5 Minimum Readsp.246Follett 2 of 5p.247Follett 2 of 5 Enable/Disablep.247BC412p.247BC412 Enable/Disablep.247BC412 Check Character Calculationp.248BC412 Minimum Readsp.248BC412 Decoding Levelp.249BC412 Length Controlp.250BC412 Set Length 1p.250BC412 Set Length 2p.251Plesseyp.252Plessey Enable/Disablep.252Plessey Check Character Calculationp.253Plessey Check Character Transmissionp.254Plessey Length Controlp.254Plessey Set Length 1p.255Plessey Set Length 2p.256Plessey Minimum Readsp.257Plessey Decoding Levelp.258Plessey Stitchingp.259Plessey Character Correlationp.259Referencesp.261RS-232 Parametersp.262RS-232 Onlyp.262RS-232/USB COM Parametersp.263Keyboard Interfacep.270Wedge Quiet Intervalp.270Intercharacter Delayp.271Intercode Delayp.272Data Formatp.273Data Editingp.273Global Prefix/Suffixp.274Global AIM IDp.275Label IDp.276Set Global Mid Label ID Character(s)p.280Character Conversionp.280Reading Parametersp.282Label Gone Timeoutp.282Good Read LED Durationp.283Scanning Featuresp.284Scan Modep.284Scanning Active Timep.285Flash On Timep.286Flash Off Timep.287Symbologiesp.288Decoding Levelsp.288Set Lengthp.288Technical Specificationsp.291Standard Cable Pinoutsp.293LED and Beeper Indicationsp.294Error Codesp.295Standard Defaultsp.297Default Exceptionsp.308Sample Bar Codesp.3111D Bar Codesp.311GS1 DataBar (RSS)p.313GS1 DataBar-14p.313Keypadp.315Scancode Tablesp.319Control Character Emulationp.319Interface Type PC AT PS/2 or USB-Keyboardp.320Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Modep.322Digital Interfacep.324IBM XTp.326Microsoft Windows Codepage 1252p.328ASCII Chartp.331
Page 330 of the Solis 842 user manual — Table of contents
Page 330 · click to enlarge
Page 330

Table of contents

Introductionp.11About the Touch TD1100p.11About this Manualp.11Overviewp.11Conventionsp.12Technical Supportp.12Datalogic Website Supportp.12Reseller Technical Supportp.12Telephone Technical Supportp.13Setupp.15Unpackingp.15Setting Up the Readerp.15Install the Interface Cablep.15Connect Host Interfacep.17Holder/Hands-Free Standp.18Interface Selectionp.19Configuring the Interfacep.19Customizing Configuration Settingsp.22Using the Programming Bar Codesp.22Interface Settingsp.23Configuring Other Featuresp.23Software Version Transmissionp.23Configuration Using Bar Codesp.25Configuration Parametersp.25Host Commands — Obey/Ignorep.27USB Suspend Modep.28RS-232 Only Interfacep.29RS-232 Standard Factory Settingsp.29Baud Ratep.29Data Bitsp.31Stop Bitsp.31Parityp.32Handshaking Controlp.33RS-232/USB-Com Interfacesp.35Standard Factory Settingsp.35Intercharacter Delayp.35Beep On ASCII BELp.36Beep On Not on Filep.36ACK NAK Optionsp.37ACK Characterp.38NAK Characterp.38ACK NAK Timeout Valuep.39ACK NAK Retry Countp.40ACK NAK Error Handlingp.41Indicate Transmission Failurep.42Disable Characterp.42Enable Characterp.43Keyboard Interfacep.45Country Modep.45Caps Lock Statep.48Numlockp.48Keyboard Numeric Keypadp.49Keyboard Send Control Charactersp.50Wedge Quiet Intervalp.51Intercharacter Delayp.52Intercode Delayp.53USB Keyboard Speedp.54USB-OEM Interfacep.57Introductionp.57Standard Factory Settingsp.57USB-OEM Device Usagep.58USB-OEM Interface Optionsp.58Wand Emulation Interfacep.59Wand Signal Speedp.59Wand Polarityp.60Wand Idle Statep.60Transmit Noisep.61Label Symbology Conversionp.62Data Formatp.63Global Prefix/Suffixp.64Global AIM IDp.65GS1-128 AIM IDp.65Label IDp.66Label ID: Pre-loaded Setsp.66Label ID: Set Individually Per Symbologyp.67Label ID Controlp.67Label ID Symbology Selectionp.68Set Global Mid Label ID Character(s)p.74Case Conversionp.75Character Conversionp.76Reading Parametersp.77Double Read Timeoutp.78Label Gone Timeoutp.80Power Save Modep.81Sleep Mode Timeoutp.82LED and Beeper Indicatorsp.83Power On Alertp.83Good Read: When to Indicatep.84Good Read Beep Typep.85Good Read Beep Frequencyp.85Good Read Beep Volumep.86Good Read Beep Lengthp.87Illumination Controlp.88Good Read LED Durationp.89Scanning Featuresp.90Scan Modep.90Stand Mode Triggered Timeoutp.91Scanning Active Timep.93Stand Mode Flashp.93Flash On Timep.94Flash Off Timep.94Stand Mode Sensitivityp.95Symbologiesp.97Introductionp.97Standard Factory Settings for Symbologiesp.97Disable All Symbologiesp.98Coupon Controlp.98UPC-Ap.99UPC-A Enable/Disablep.99UPC-A Check Character Transmissionp.99Expand UPC-A to EAN-13p.100UPC-A Number System Character Transmissionp.100In-Store Minimum Readsp.101UPC-Ep.102UPC-E Enable/Disablep.102UPC-E Check Character Transmissionp.102Expand UPC-E to EAN-13p.103Expand UPC-E to UPC-Ap.103UPC-E Number System Character Transmissionp.104UPC-E Minimum Readp.104EAN 13p.105EAN 13 Enable/Disablep.105EAN 13 Check Character Transmissionp.105EAN-13 Flag 1 Characterp.106EAN-13 ISBN Conversionp.106ISSN Enable/Disablep.107EAN 13 Minimum Readsp.107EAN 8p.108EAN 8 Enable/Disablep.108EAN 8 Check Character Transmissionp.108Expand EAN 8 to EAN 13p.109EAN 8 Both Guards Substitutionp.109EAN 8 Guard Insertionp.110EAN 8 Guard Substitutionp.110EAN 8 Minimum Segment Length Blockp.111EAN 8 Minimum Readsp.113EAN 8 Stitch Exact Label Halvesp.114EAN 8 Stitch Unlike Label Halvesp.114EAN Two Labelp.115EAN Two Label Enable/Disablep.115EAN Two Label Combined Transmissionp.115EAN Two Label Minimum Readsp.116UPC/EAN Global Settingsp.117UPC/EAN Decoding Levelp.117UPC/EAN Correlationp.118UPC/EAN Price Weight Checkp.119UPC-A Minimum Readsp.120UPC/EAN Guard Insertionp.121UPC/EAN Stitch Exact Label Halvesp.121UPC/EAN Stitch Unlike Label Halvesp.122UPC/EAN Minimum Segment Lengthp.123Add-Onsp.125Optional Add-onsp.125Optional Add-On Timerp.127P2 Add-Ons Minimum Readsp.129P5 Add-Ons Minimum Readsp.130GS1-128 Add-Ons Minimum Readsp.131GS1 DataBarTM Omnidirectionalp.132GS1 DataBar Omnidirectional Enable/Disablep.132GS1 DataBar Omnidirectional GS1-128 Emulationp.132GS1 DataBar Omnidirectional Minimum Readsp.133GS1 DataBarTM Expandedp.134GS1 DataBar Expanded Enable/Disablep.134GS1 DataBar Expanded GS1-128 Emulationp.134GS1 DataBar Expanded Minimum Readsp.135GS1 DataBar Expanded Length Controlp.136GS1 DataBar Expanded Set Length 1p.136GS1 DataBar Expanded Set Length 2p.137GS1 DataBarTM Limitedp.138GS1 DataBar Limited Enable/Disablep.138GS1 DataBar Limited GS1-128 Emulationp.138GS1 DataBar Limited Minimum Readsp.139Code 39p.140Code 39 Enable/Disablep.140Code 39 Check Character Calculationp.141Code 39 Check Character Transmissionp.142Code 39 Start/Stop Character Transmissionp.142Code 39 Full ASCIIp.143Code 39 Quiet Zonesp.144Code 39 Minimum Readsp.145Code 39 Decoding Levelp.146Code 39 Length Controlp.147Code 39 Set Length 1p.148Code 39 Set Length 2p.149Code 39 Interdigit Ratiop.150Code 39 Character Correlationp.152Code 39 Stitchingp.152Code 32 (Italian Pharmaceutical)p.153Code 32 Enable/Disablep.153Code 32 Feature Setting Exceptionsp.153Code 32 Check Character Transmissionp.154Code 32 Start/Stop Character Transmissionp.154Code 39 CIP (French Pharmaceutical)p.155Code 39 CIP Enable/Disablep.155Code 128p.155Code 128 Enable/Disablep.155Expand Code 128 to Code 39p.156Code 128 Check Character Transmissionp.156Code 128 Function Character Transmissionp.157Code 128 Sub-Code Change Transmissionp.157Code 128 Quiet Zonesp.158Code 128 Minimum Readsp.159Code 128 Decoding Levelp.160Code 128 Length Controlp.161Code 128 Set Length 1p.162Code 128 Set Length 2p.163Code 128 Character Correlationp.164Code 128 Stitchingp.164GS1-128p.165GS1-128 Enablep.165Interleaved 2 of 5 (I 2 of 5)p.166I 2 of 5 Enable/Disablep.166I 2 of 5 Check Character Calculationp.167I 2 of 5 Check Character Transmissionp.168I 2 of 5 Minimum Readsp.169I 2 of 5 Decoding Levelp.170I 2 of 5 Length Controlp.171I 2 of 5 Set Length 1p.172I 2 of 5 Set Length 2p.173I 2 of 5 Character Correlationp.174I 2 of 5 Zero Patternp.174I 2 of 5 Stitchingp.175Interleaved 2 of 5 CIP HRp.175Interleaved 2 of 5 CIP HR Enable/Disablep.175Datalogic 2 of 5p.176Datalogic 2 of 5 Enable/Disablep.176Datalogic 2 of 5 Check Character Calculationp.176Datalogic 2 of 5 Check Character Transmissionp.177Datalogic 2 of 5 Minimum Readsp.177Datalogic 2 of 5 Decoding Levelp.178Datalogic 2 of 5 Length Controlp.178Datalogic 2 of 5 Set Length 1p.179Datalogic 2 of 5 Set Length 2p.180Datalogic 2 of 5 Interdigit Ratiop.181Datalogic 2 of 5 Character Correlationp.183Datalogic 2 of 5 Stitchingp.183Codabarp.184Codabar Enable/Disablep.184Codabar Check Character Calculationp.184Codabar Check Character Transmissionp.185Codabar Start/Stop Character Transmissionp.185Codabar Start/Stop Character Setp.186Codabar Start/Stop Character Matchp.187Codabar Quiet Zonesp.188Codabar Minimum Readsp.189Codabar Decoding Levelp.190Codabar Length Controlp.191Codabar Set Length 1p.192Codabar Set Length 2p.193Codabar Interdigit Ratiop.194Codabar Character Correlationp.196Codabar Stitchingp.196ABC Codabarp.197ABC Codabar Enable/Disablep.197ABC Codabar Concatenation Modep.197ABC Codabar Dynamic Concatenation Timeoutp.198ABC Codabar Force Concatenationp.198Code 11p.199Code 11 Enable/Disablep.199Code 11 Check Character Calculationp.200Code 11 Check Character Transmissionp.200Code 11 Minimum Readsp.201Code 11 Length Controlp.202Code 11 Set Length 1p.202Code 11 Set Length 2p.203Code 11 Interdigit Ratiop.204Code 11 Decoding Levelp.206Code 11 Character Correlationp.207Code 11 Stitchingp.207Standard 2 of 5p.208Standard 2 of 5 Enable/Disablep.208Standard 2 of 5 Check Character Calculationp.208Standard 2 of 5 Check Character Transmissionp.209Standard 2 of 5 Minimum Readsp.209Standard 2 of 5 Decoding Levelp.210Standard 2 of 5 Length Controlp.210Standard 2 of 5 Set Length 1p.211Standard 2 of 5 Set Length 2p.212Standard 2 of 5 Character Correlationp.213Standard 2 of 5 Stitchingp.213Industrial 2 of 5p.214Industrial 2 of 5 Enable/Disablep.214Industrial 2 of 5 Check Character Calculationp.214Industrial 2 of 5 Check Character Transmissionp.215Industrial 2 of 5 Length Controlp.215Industrial 2 of 5 Set Length 1p.216Industrial 2 of 5 Set Length 2p.217Industrial 2 of 5 Minimum Readsp.218Industrial 2 of 5 Stitchingp.219Industrial 2 of 5 Character Correlationp.219IATAp.220IATA Enable/Disablep.220IATA Check Character Transmissionp.220ISBT 128p.221ISBT 128 Concatenationp.221ISBT 128 Concatenation Modep.221ISBT 128 Dynamic Concatenation Timeoutp.222ISBT 128 Force Concatenationp.223ISBT 128 Advanced Concatenation Optionsp.223MSIp.224MSI Enable/Disablep.224MSI Check Character Calculationp.224MSI Check Character Transmissionp.225MSI Length Controlp.225MSI Set Length 1p.226MSI Set Length 2p.227MSI Minimum Readsp.228MSI Decoding Levelp.229Code 93p.230Code 93 Enable/Disablep.230Code 93 Check Character Calculationp.230Code 93 Check Character Transmissionp.231Code 93 Length Controlp.231Code 93 Set Length 1p.232Code 93 Set Length 2p.233Code 93 Minimum Readsp.234Code 93 Decoding Levelp.235Code 93 Quiet Zonesp.236Code 93 Stitchingp.237Code 93 Character Correlationp.237Codablock Fp.238Codablock F Enable/Disablep.238Codablock F EAN Enable/Disablep.238Codablock F AIM Checkp.239Codablock F Length Controlp.239Codablock F Set Length 1p.240Codablock F Set Length 2p.241Code 4p.242Code 4 Enable/Disablep.242Code 4 Check Character Transmissionp.242Code 4 Hex to Decimal Conversionp.243Code 5p.243Code 5 Enable/Disablep.243Code 5 Check Character Transmissionp.244Code 5 Hex to Decimal Conversionp.244Code 4 and Code 5 Common Configuration Itemsp.245Code 4 and 5 Decoding Levelp.245Code 4 and Code 5 Minimum Readsp.246Follett 2 of 5p.247Follett 2 of 5 Enable/Disablep.247BC412p.247BC412 Enable/Disablep.247BC412 Check Character Calculationp.248BC412 Minimum Readsp.248BC412 Decoding Levelp.249BC412 Length Controlp.250BC412 Set Length 1p.250BC412 Set Length 2p.251Plesseyp.252Plessey Enable/Disablep.252Plessey Check Character Calculationp.253Plessey Check Character Transmissionp.254Plessey Length Controlp.254Plessey Set Length 1p.255Plessey Set Length 2p.256Plessey Minimum Readsp.257Plessey Decoding Levelp.258Plessey Stitchingp.259Plessey Character Correlationp.259Referencesp.261RS-232 Parametersp.262RS-232 Onlyp.262RS-232/USB COM Parametersp.263Keyboard Interfacep.270Wedge Quiet Intervalp.270Intercharacter Delayp.271Intercode Delayp.272Data Formatp.273Data Editingp.273Global Prefix/Suffixp.274Global AIM IDp.275Label IDp.276Set Global Mid Label ID Character(s)p.280Character Conversionp.280Reading Parametersp.282Label Gone Timeoutp.282Good Read LED Durationp.283Scanning Featuresp.284Scan Modep.284Scanning Active Timep.285Flash On Timep.286Flash Off Timep.287Symbologiesp.288Decoding Levelsp.288Set Lengthp.288Technical Specificationsp.291Standard Cable Pinoutsp.293LED and Beeper Indicationsp.294Error Codesp.295Standard Defaultsp.297Default Exceptionsp.308Sample Bar Codesp.3111D Bar Codesp.311GS1 DataBar (RSS)p.313GS1 DataBar-14p.313Keypadp.315Scancode Tablesp.319Control Character Emulationp.319Interface Type PC AT PS/2 or USB-Keyboardp.320Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Modep.322Digital Interfacep.324IBM XTp.326Microsoft Windows Codepage 1252p.328ASCII Chartp.331
Page 331 of the Solis 842 user manual — { | } ~ DEL
Page 331 · click to enlarge
Page 331

ASCII Chart

ASCII

ASCII

ASCII

ASCII

Char.

No.

Char.

No.

Char.

No.

Char.

No.

NUL SOH

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

SP

20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F

40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F

‘ a b c d e

60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F

! “ # $ %

A B C D E F G H

STX ETX EOT ENQ

ACK

BEL

’ ( ) * +

BS HT

I J K

LF VT FF CR SO

, - . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?

L M

N O

n o p q

SI DLE DC1 DC2 DC3 DC4 NAK SYN

P Q R S T U V W

t u v w

ETB CAN

X Y Z

EM SUB ESC

[ \ ] ^ _

{ | } ~ DEL

FS GS RS US

Show 11 more labels / short text on this page
Hex · Hex · Hex · Hex · @ · & · f g h · i j k · l m · r s · x y z
Page 332 of the Solis 842 user manual — www.datalogic.com
Page 332 · click to enlarge
Page 332

www.datalogic.com

Datalogic ADC, Inc. 959 Terry Street Eugene, OR 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140

©2012-13 Datalogic ADC, Inc. 820050614 (Rev C) March 2013

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Solis 842

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Solis 842

Be the first to ask — other owners or our team will answer.

Original document