Digital module • Monocular Pulsar 10x32
Optical characteristics Generation Optical magnification, x Optical magnification of the digital module, x Lens Field of view, degree / m (at 100m distance) Exit pupil, mm Resolution, lines/mm, at least Max. detection range with attachable laser illuminator, m / yds* Close-up distance, m CCD array characteristics Output video signal standard Type of CCD array Resolution, pixel Format (physical dimensions) Display characteristics Type Resolution, pixel Diagonal, mm Attachable laser illuminator Wavelength, nm Equivalent power (variation range), mW Safety class for laser equipment according to IEC 60825-1:2007 Output power for laser radiation, not more than Operational characteristics Operating voltage, V / Battery External power supply Operating temperature Operation time with one set of rechargeable batteries (built-in IR off/on), hour Operation time with external power supply EPS3/EPS5, hour Operating frequency of wireless remote control Operating voltage, V / Battery of RC Dimensions of the assembled unit, mm / inch Dimensions of the digital module, mm Weight of the assembled unit (without / with batteries), kg // oz
Digital 10 1 50 mm ƒ1.0 5 / 8.7 30 50 400 / 473 5
** Varies by shipment. For improvement purposes, design of this product is subject to change.
Digital Night Vision Forward DN55 is a combination of a digital module and 10-power monocular for observation both in the twilight and daytime. To operate in total darkness the unit can be employed with an eyesafe laser IR Illuminator. The unit is equipped with a video output for recording video in real time. The Forward DN55 is designed for professional and amateur use, such as observation, security, night and day video recording.
CCIR ICX255 500 (H) х 582(V) 1/3” (4.8x3.6mm)
915 150 (90-110-150) 1 20 mW
3.7 - 6 V / 4xAA DC 8.4-15V -25 °C... +50 °C / -13 °C... +122 °C...
2 / 1.5 7 / 18 2.4 GHz 3 / CR2032 246x82x117 / 9.7x3.2x4.6 155x82x117 / 6.1x3.2x4.6 0.8 / 0.89 // 28.2 / 31.4
Characteristics of the monocular Optical magnification, x Eye relief, mm Resolution, angular minutes Dimensions (LxWxH), mm / inch Weight, kg / oz
10 14 8.7 141x68x68 / 5.5x2.7x2.7 0.24 / 8.5
* Max. detection range of an object measuring 1.7x0.5 m in natural night conditions (0.05 lux, quarter moon).
OLED 640х480 8


Knob for attaching the laser IR Illuminator on digital module
Knob for activating and adjusting power of IR laser Illuminator
“Power” jack connection to external power supply
Laser IR Illuminator lens holder
Laser IR Illuminator locking ring
“IR” button
“SumLight™” button


The device was designed for extensive usage. To ensure longevity and performance, please adhere to the following:
in the unit. Attention! We suggest that you use battery packs EPS3 or EPS5
ensuring from 7 to 18 hours of operation.


If necessary, do the horizon adjustment according to the instructions in section 10. In order to remove the digital module, move the lock (10) to the right and turn the digital module clockwise until it clicks. Pull the digital module and remove it carefully.
The digital module can also be mounted on a day optical device, mounting procedure is as follows:

Choose an adapter with an insert of the required diameter depending on the outer diameter of the bell of the daylight device. The figures 42 mm, 50 mm, 56 mm in adapter's model name correspond to the optical diameter of the device’s bell. Measure the outer diameter of the housing of your device’s bell and select an insert in accordance with reference data in the table below. Example. If the lens diameter of your day device is 42 mm, and the measured outer diameter of the housing of the device’s bell is 47.2 mm, you need to use an insert with marking “Ø 47”.
Compatibility chart of inserts for the day devices
Lens diameter of day device, mm
Outer diameter of the housing of device's objective lens, mm
Adjusting display position If you noticed that after mounting the digital module on your day device, the image on the display is off the centre of the field of view (pic. А, B), you can centre the image: - unsnap the clamp (20), - incline and move the digital module together with the adapter to achieve image position as shown in image C. - then re-lock the clamp in place. Important! Image position does not affect the point of impact.

OPERATION
Starting the unit and image setup Install the batteries in accordance with the “Installation of batteries” section or connect an external power supply. Rotate the lens cap (1) 45 degrees counterclockwise to open and remove it. Turn on the “ON” button (7) the display will light up in a couple of seconds. Rotate the diopter adjustment ring to see sharp image of symbols on the display. To adjust display brightness, rotate the encoder (5). Brightness level from 0 to 20 is shown next to the icon in the centre of display. Press the encoder (5) to switch to display contrast setup mode (16). Contrast level from 0 to 20 is shown next to icon in the centre of display. Choose a still object that is, for instance, 100 metres away. Rotate the lens focus knob (2) to achieve best possible image sharpness. In low light conditions or in complete darkness attach and turn on the built-in laser IR Illuminator by rotating the knob (6) clockwise (make sure the IR is mounted). Rotate the knob (6) to adjust IR power (icons on the data panel): clockwise – to increase power; counterclockwise – to decrease power. Icon means that the IR Illuminator was not attached. IR
Remove the cover (18) from the Cover Ring Adapter 42mm (#79121) by turning it clockwise. To remove the cover from the Cover Ring Adapter 50 mm (#79122) or 56 mm (#79123), turn the cover counterclockwise. Put the insert (22) into the adapter, unsnap the clamp (20) of the adapter (19) and firmly mount the adapter on the device's bell (23) to ensure that the surface in the bottom part of the adapter is located above the barrel. Important! The insert must be installed with the narrowed part facing downward (see the scheme). Snap the clamp. Attention! Before installation it is advised to degrease the device's bell. Use a hex-nut wrench to tighten the screw (21) to ensure that the adapter with the insert fit closely to the device's bell when the clamp rotates. When tightening the screw, the holding power must be 0.7-0.9 Holding power can be checked a torque screwdriver. N·m. with Insert the optical device into the adapter so that the teeth in the adapter's body enter the notches (17). Turn the digital module counterclockwise until it clicks to ensure that the clamp (10) enters the groove in the adapter.

When finished, turn off the device by pushing the “ON” button (7). Close the lens cap (1).
To exit main menu, keep the encoder (5) pressed for two seconds. Or wait ten seconds to exit automatically.
Enter the menu by keeping the encoder (5) pressed for two seconds. Rotate the encoder (5) to choose the icon in submenu M1 and push the encoder – the following settings will be restored to default values: - SumLight - On; Autocontrast - Off; Brightness - 10; Contrast - 10.
The menu includes two submenus and which include items as follows: - function “Sum Light™” - function “Autocontrast” - return to default settings
- function “Clock” - v ideo output selection - function “Horizon adjustment” - wireless remote control
The active submenu is highlighted with a frame To switch to the other submenu, rotate the encoder and move the cursor to or (the frame will be flashing) and push the encoder.
SumLight™ After the digital module is switched on for the first time, the Sum Light™ activates automatically. The use of Sum Light™ substantially increases sensitivity of the CCD array thus enabling observation in low light without using the IR Illuminator. When using the digital module at a sufficient level of night illumination, the Sum Light™ function can be deactivated manually (using the wireless RC or the menu). Hereafter on activation the module remembers the function status before it was turned off.
NOTE: higher sensitivity causes an increased noise level in the picture, lower frame rate; image slows down, if the unit is rapidly moved from one side to the other, the picture may be blurred for a moment. Neither of these effects is a flaw of the unit. After the SumLight™ Signal Processing Program is activated, light dots (pixels) may appear in the field of view which is explained by operation peculiarities of this function. This is not a defect either.
If the lines do not match, release the clamp and re-mount the digital
module to ensure its horizontal position . Check that the lines match, snap the clamp and tighten the screw.
Restore default settings

The Forward DN55 is supplied with an attachable laser IR Illuminator (915 nm wavelength) designed to operate in lowlight conditions and full darkness. The Illuminator operates in the invisible range which helps provide covert observation. To attach the Illuminator, unscrew the plug, mount the Illuminator into the grooves and screw the knob (4) clockwise. Adjustment: To adjust the required size and shape of the IR beam from spot to flood, rotate the lens holder (12) until you achieve quality image in your night vision device. If you need to adjust the IR spot position, turn the locking ring (13) 5-10 degrees counterclockwise. Match the IR spot with the image viewed through a night vision device by moving the IR lens holder (12) transversely. Tighten the locking ring (13). Note. On the right side of the digital module there is a Weaver rail (26) (optional) which allows attachment of auxiliary IR Illuminator or other accessories.
Always store the unit in its case in a dry, well-ventilated space. For prolonged storage, remove the batteries.
Video output jack (3) is designed to connect external recording devices and transmitting video signal to a monitor. Select suitable video output signal – PAL and NTSC (see corresponding item of section “Main menu”). Attach signal receiver to the Video output jack (3) and turn on the digital module. Icon on the panel will appear.
Listed below are some potential problems that may occur when using the device. Carry out the recommended checks and troubleshooting steps in the order listed. Please note that the table does not list all of the possible problems. If the problem experienced with the scope is not listed, or if the suggested action meant to correct it does not resolve the problem, please contact the manufacturer.

problem possible cause(s) corrective action
The device will not turn on.
Batteries have been wrongly installed. Oxidized contact points in the battery compartment due to “leaky” batteries or contact points becoming exposed to a chemically- reactive solution. The batteries are empty.
Reinstall the batteries with the correct polarity orientation. Clean the battery compartment, focusing on the contacts.
Install fresh batteries.
The image is blurred.
Dust and condensate are covering the outside optical surfaces of the digital module, monocular or optical device.
Clean the lens surfaces with a blower and soft lens cloth. Let the unit dry by leaving it in a warm environment for 2-3 hours.
The device will not focus.
Wrong settings.
Adjust the unit according to the instructions set forth in the Section 10 “Operation” and check the surfaces of the lenses and clean them if necessary from dust, condensation, frost, etc; to prevent fogging in cold weather, apply a special anti-fog solution.
The wireless remote control does not respond.
Remote control is not activated or wrongly activated. Battery is low.
Activate the remote according to instructions in section 11. Install a new CR2032 battery.
Barely visible texture which does not hinder detection range or efficiency of observation can be noticed on the display after the built-in laser IR Illuminator is activated.
This is normal for eye safe laser IR Illuminators.
This is not a defect.

Wrong insert is chosen. Choose the appropriate insert. Check the gap between the lips of the adapter.
The clamp of the adapter cannot be opened.
The IR Illuminator is off the centre.
The beam of the IR is not adjusted.
Do the settings described in section 11 “Mounting and using the IR Illuminator”.
The display is off the centre.
Unclamp the clamp and set the display in the centre (see section 8 “Operation”). The position of the digital module on your day device is not adjusted.
Peculiarities of CCD array Sony CCD arrays employed in Pulsar digital night vision devices, feature high quality. However certain pixels (or groups of pixels) with increased luminosity (lighter or darker) are allowed. These defects can be seen when conducting observation not only in the nighttime but in the day time too, especially if Sum Light™ function is active. Presence of light and dark pixels and other minor defects of a CCD array (up to 4%) are acceptable in accordance with regulations of the company SONY. Visibility on the screen of light pixels also depends on the type of CCD array, heating temperature during operation.
Laser aperture
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.