029-4004-02/V1.00/2016-01/SH © Phonak AG All rights reserved

Phonak Communications AG Laenggasse 17 CH-3280 Murten Switzerland
7 613275 461518


2.1 In the box
2.2 How Roger Table Mic works
Roger Table Mic transmits the meeting participants‘ voices directly into your ears. The system consists of three main elements: the hearing aids, Roger receivers and one or more Roger Table Mic(s).
1 or 2 Roger Table Mic
Remote control Power supply with country adapter and

Hearing aid with Roger receiver
Audio cable RCA / Cinch adapter
Roger Table Mic and the hearing aids typically work within a range of up to 30 meters / 100 feet. Note that human bodies and walls may reduce this distance. The furthest range is possible when you can see Roger Table Mic (i.e. line of sight).
charging cable · Soft case · Quick Setup Guide

2.3 Device descriptions
2.4 Indicator lights
a a Indicator light b Microphones c On / Off / Mute d Connect e Charging input f Audio input
Microphone / audio input muted
Low battery – charge Roger Table Mic
Roger Table Mic has lost connection to the other Roger microphone(s). Press the Connect button to reinitialize the network.
c b a a Indicator light b Mute on c Mute off d Screw e Battery cover

3.1 Setting up the power supply
Remove / Change: 1. Pull back the tab on the universal power supply.
The universal power supply comes with an adapter for your country. To charge your device you first need to attach the correct adapter to the power supply.
AUS

3.2 Charging Roger Table Mic

Roger Table Mic contains a built-in lithium polymer battery with fast-charge capability.
To charge Roger Table Mic, connect the supplied charger. The indicator light will turn orange to indicate it is charging.
An empty battery will reach its maximum charge in approximately 2 hours. Charging is complete when the indicator light turns solid green.

When charging Roger Table Mic for the first time, let
it charge for at least two hours, even if the battery indicator light is not lit or turns green earlier.

You can also charge Roger Table Mic by connecting it
3.4 Switching on and off
to a computer’s USB port using the supplied charging cable.
To switch Roger Table Mic on, press the on/off button for one second until the indicator light turns green.
Indicator lights (battery status) Indicator light Meaning

Low battery – charge Roger Table Mic. In addition, you will hear beeps in your hearing aids.
3.3 Setting up the remote control
On delivery the remote control battery is protected by a plastic tab.
Remove the plastic tab from the battery to activate the remote control
Charging · Fully Charged

3.5 Using Roger receivers
3.6 Connecting a receiver
Using Roger MyLink If your Roger receiver is a Roger MyLink, switch the Roger MyLink on and hang it around your neck. Make sure your hearing aids are set to T / MT / T-Coil mode.

Your hearing care professional may already have connected Roger Table Mic to your hearing aids. If this is not the case, connect your receiver to Roger Table Mic as follows:
The Roger MyLink User Guide provides more detailed information on using Roger MyLink.
Using Roger receivers attached to your hearing aids If you have Roger receivers that attach directly to your hearing aids, make sure these are properly attached and each hearing aid is set to its Roger / FM / DAI / EXT / AUX program.


The indicator light will turn green for two seconds to confirm a successful connection.
3.7 Connecting the remote control
The remote control is connected to Roger Table Mic at the factory. If needed, you can connect the remote control to any number of additional Roger Table Mics.
You can connect an infinite number of Roger
receivers to Roger Table Mic.
Indicator light (connection status) After pressing the Connect button, the following feedback may be given by the indicator light:
The Roger Table Mic flashes purple four times to indicate a successful connection.
Connection was successful – the Roger receiver is connected to Roger Table Mic.
Indicator light (connection status) After conneting the remote control, the following feedback may be given by the indicator light:
Roger Table Mic could not find a Roger receiver. Move Roger Table Mic closer to the Roger receiver and make sure the Roger receiver is powered on. Then try to connect again.
Remote control connection was successsful.
The Roger receiver is not compatible with Roger Table Mic.
Indicator light Meaning · Connecting · Indicator light Meaning

Roger Table Mic is a flexible, intelligent product. It detects which situation you are in and adapts its sound processing settings automatically to provide you the best speech understanding possible.
4.1 Connecting to multimedia devices
You can connect Roger Table Mic to an audio source – such as a conference telephone, tablet or computer - to hear its audio signal directly in your hearing aids.
Place Roger Table Mic in the middle of a table to listen to a group of people.


After you have activated the
multimedia device’s audio signal, Roger Table Mic will detect this signal and mute its own microphone.
Table Mic close to noise sources such as projectors and laptops.

Roger technology allows you to use multiple microphones in parallel by connecting additional Roger microphones.
The indicator lights of both microphones will turn green for two seconds to indicate successful connection.
5.1 Connect
It’s possible to add up to 10 other Roger microphones
to Roger Table Mic.
To connect another microphone to your Roger Table Mic, follow these steps:
If you want to connect a Roger Pen to Roger
Table Mic, press Connect on the Roger Pen instead of the Roger Table Mic.


5.2 Using additional microphones
Indicator light (Connection status) After pressing the Connect button, the following feedback may be given by the indicator light:
Additional Roger Table Mics are placed so that you can hear the people seated around the table. Hand over any wearable Roger microphones to your speakers. Make sure they are worn properly (pointing to the mouth and within 20 cm / 8 inches).
Connection was successful - the other Roger microphone is now connected to Roger Table Mic.
The Roger microphones automatically detect when someone talks, before instantly transmitting the voice to your hearing aids.
Roger Table Mic could not find another Roger microphone. Move Roger Table Mic closer to the other Roger microphone and make sure both microphones are switched on. Then try Connect again.
If a speaker wearing a microphone wants to temporarily leave the group, they should mute their microphone by firmly pressing the on/off button.
The other Roger microphone is not compatible with Roger Table Mic. Please do a software update using Roger Upgrader or contact your hearing care professional.

Indicator light Meaning

If there is an issue with the network, press the
6.1 Muting
Connect button on one of the microphones to reinitialize the network.

Muting the microphone is especially useful during meeting breaks or when you want to focus on a presenter without being disturbed by side conversations from other participants.
Indicator light (multiple microphone status) When using multiple Roger microphones, the following feedback may be given by the indicator light:
The Roger microphone is muted. Unmute it by pressing the on/off button or the mute off button on the remote control.
Roger Table Mic has lost connection to the other Roger microphone(s). Press the Connect button to reinitialize the network.
When muted, the indicator light will turn solid violet.
Indicator light (Mute) Indicator light Meaning
Microphone / audio input muted
Indicator light Meaning

6.2 Disconnecting Roger devices (NewNet)
Most probable cause(s) Solution(s) I cannot switch Roger Table Mic on
To disconnect Roger Table Mic from any connected receivers or other Roger microphones, hold the Connect button for 7 seconds. The indicator light will turn orange when Roger Table Mic has been dis- connected from all connected devices.
J JThe battery is empty J JCharge Roger Table Mic for at
least two hours I cannot understand the speaker
J JThe microphone is not
J J Move Roger Table Mic closer to
J JThe microphone openings are
J J Make sure the microphone
openings are not covered by dirt or an object I cannot hear the speaker’s voice even though Roger Table Mic is switched on
covered by dirt or an object
J JThe microphone has been
J JCheck the indicator light – if it
is violet, briefly press the on/off button to activate the microphones
You can now start to re-connect Roger receivers or Roger microphones with Roger Table Mic.
J JCheck that your hearing aids
J JYour hearing aids are not
set to the correct program
are set to the correct program (Roger / FM / DAI / EXT / AUX)
Reset If Roger Table Mic stops responding to commands, you can reset it by pressing the on/off and Connect buttons together for 10 seconds.
J JHold Roger Table Mic close to
J JYour Roger receivers are not
connected to Roger Table Mic
each Roger receiver in turn and press the Connect button
J J Roger Table Mic was part of a
J JPress the Connect button on

Most probable cause(s) Solution(s) I keep losing the audio signal
Most probable cause(s) Solution(s) Roger Table Mic has stopped working
J JDistance between Roger
J JGo closer to Roger
J JSoftware issue J JReboot Roger Table Mic by
Table Mic and Roger receiver is too large
simultaneously pressing the on/off and Connect button I am not able to connect my Roger Table Mic with another Roger microphone
J JThere are obstacles between
J JMake sure you can see the
Roger Table Mic (line of sight) The volume of my multimedia device is too low
you and Roger Table Mic
J JThere is a software incompati-
J JUpgrade all your Roger
microphones using the Roger Upgrader available on the Phonak website or contact your local Phonak dealer. I am not able to connect my Roger Table Mic with another Roger microphone
J JIncorrect volume settings J JIncrease volume of the audio
source I cannot hear my multimedia device
J JThe audio source is muted
J JUnmute the audio source
J JThe microphone is not
J JMake sure both devices are
J JRoger Table Mic is muted
J JUnmute Roger Table Mic
J JRoger Table Mic is using the
J JSwitch on Roger Table Mic to
J JThe microphone is not close
J JMove the microphone closer to
listen to the audio source via the audio cable Roger Table Mic is switched on but it‘s light is blinking blue
audio cable but is not switched on
J JThe microphone network is
J JFirmly press the Connect
J JRoger Table Mic was part of a
J JPress the connect button on
button on one microphone to reinitialize the network The remote control is not responding
Table Mic Roger Table Mic’s light is blinking red (double flash)
J JIts battery charge is low J JCharge Roger Table Mic as
J JThe battery is empty J JReplace the battery

8.1 Important safety information
8.2 Hazard warnings
Please read the information on the following pages
Keep this device out of reach of children aged under
before using your Phonak device.
3 years.
This symbol on the product or its packaging means
Opening the device might damage it. If problems
that it should not be disposed of with your other household waste. It is your responsibility to dispose of your waste equipment separately from the municipal waste stream. The correct disposal of your old appliance will help prevent potential negative consequences for the environment and human health.
occur that cannot be resolved by following the guidelines in the Troubleshooting section of this User Guide, consult your hearing care professional.
Your device should only be repaired by an authorized
service center. Changes or modifications to this device that were not explicitly approved by Phonak are not permitted.
Please dispose of electrical components in accordance
with your local regulations.
Do not use your device in areas where electronic
equipment is prohibited. If in doubt, please ask the person in charge.
Device should not be used on aircrafts unless
specifically permitted by flight personnel.

External devices should only be connected if they
8.3 Product safety information
have been tested in accordance with corresponding IECXXXXX standards.
Protect the device from excessive shock and vibration.
Only use accessories that are approved by Phonak AG.
Do not expose your device to temperatures and
humidity outside of the recommended conditions stated in this User Guide.
Using your device’s cables in any way contradictory to
their intended purpose (e. g., wearing the USB cable around the neck) can cause injury.
Never use a microwave or other heating devices to
dry the device.
When operating machinery, ensure that no parts of
your device can get caught in the machine.
Clean the device using a damp cloth. Never use
household cleaning products (washing powder, soap, etc.) or alcohol to clean the device.
Do not charge device while it is on your body.
Only recharge your device using chargers supplied
electrical outlets.
by Phonak or by stabilized chargers providing 5VDC and ≥500 mA.
Do not use the hearing aids in explosive area
(oxygen-rich environments, mines or industrial areas with danger of explosions).
Do not connect an USB or audio cable to your device
that exceeds 3 meters (9 ft) in length.
When the device is not in use, turn it off and store it
safely.

Protect the device from excessive moisture (bathing,
The device has a built-in rechargeable battery. This
swimming), heat (radiator, car dashboard), and direct contact with skin when sweating (workout, fitness, sport).
battery can be charged and discharged hundreds of times but may eventually wear out. The battery may then only be replaced by authorized personnel.
X-ray radiation, CT or MRI scans may destroy or
8.4 Other important information
adversely affect the correct functioning of the device.
S S Persons with pacemakers or other medical devices
Do not use excessive force when connecting your
should ALWAYS consult their physician or the manufacturer of their device BEFORE using the device. The use of the device with a pacemaker or other medical devices should ALWAYS be in accordance with the safety recommendations of the physician responsible for your pacemaker or the pacemaker manufacturer. S S Device collects and stores internal technical data.
device to its different cables.
Insert the device into the docking station as
indicated. Incorrect insertion may damage the device.
Protect all openings (microphones, audio input and
charger) from dirt and debris.
This data may be read by a hearing care professional in order to check the device, as well as to help you use your device correctly. S S The digital signal sent from the device to a connected
If the device has been dropped or damaged, if it
overheats during charging, has a damaged cord or plug, or has been dropped into liquid, stop using your device and contact your hearing care professional.
receiver cannot be overheard by other devices which are not in the microphone’s network.

9.1 Local warranty
9.3 Warranty limitation
Please ask the hearing care professional, where you purchased your device, about the terms of the local warranty.
This warranty does not cover damage from improper handling or care, exposure to chemicals, immersion in water or undue stress. Damage caused by third parties or non-authorized service centers renders the warranty null and void. This warranty does not cover any services performed by a hearing care professional in his / her office.
9.2 International warranty
Phonak offers a one year limited international warranty, valid as of the date of purchase. This limited warranty covers manufacturing and material defects. The warranty is valid only if proof of purchase is shown.
Authorized hearing care professional (stamp / signature):
Serial number:
Date of purchase:

This device is designed such that it functions without problems or restrictions if used as intended, unless otherwise noted in these user guides.
The CE symbol is confirmation by Phonak Communications AG that this Phonak product is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
Australian EMC and Radiocom- munications compliance label.
This symbol indicates that it is important for the user to read and take into account the relevant information in this user guide.
Temperature operation: 0° to +40° Celsius (+32° to +104° Fahrenheit). Temperature storage: -10° to +60 Celsius (+14° to +140° Fahrenheit).
This symbol indicates that it is important for the user to pay attention to the relevant warning notices in this user guide.
Humidity transportation: Up to 90% (non condensing). Humidity storage: 0% to 70%, if not in use.
Atmospheric pressure: 500 hPA to 1100 hPA.
Operating conditions

The symbol with the crossed-out garbage bin is to make you aware that this device may not be thrown away as normal household waste. Please dispose of old or unused device, at waste disposal sites intended for electronic waste, or give your device to your hearing care professional for disposal. Proper disposal protects the environment and health. This product has an embedded, non- replaceable battery. Do not attempt to open the product or remove the battery as this may cause injury and damage the product. Please contact the local recycling facility for removal of the battery.