Omron MicroAIR - U22

33 pages·1.5 MB·Miscellaneous·PDF·ENFRITJA
Omron MicroAIR - U22
Table of Contents 19 sections Instruction manual · U22 · Table of contents · Safety precautions · … ShowHide
Page 1 of the Omron MicroAIR - U22 user manual — Instruction manual
Page 1 · click to enlarge
Page 1

Instruction manual

U22

Omron MicroAIR - U22 — Instruction manual diagram (page 1)
Fig. 1 · Instruction manual
Omron MicroAIR - U22 — Instruction manual diagram (page 1)
Fig. 2 · Instruction manual
Page 4 of the Omron MicroAIR - U22 user manual — Names and functions of the parts
Page 4 · click to enlarge
Page 4

Names and functions of the parts

Names and functions of the parts

Omron MicroAIR - U22 — Names and functions of the parts diagram (page 4)
Fig. 3 · Names and functions of the parts
10. Container Contains the medication (7 ml max.) 11. Medication container release button Medication container can be removed when the buttons on both sides are pushed. 12. Electrodes Connects the main unit with the vibrator. 13. Battery Low Indicator An orange light blinks when the batteries are low. 14. ON/OFF button 15. Electrodes Connects the vibrator with the main unit. 16. Power indicator A green light turns on when the power is on. 17. Main unit

1. Mesh Cap Contains metal alloy mesh for nebuli- sation. 2. Nebulisation port Nebulised medication exits here. 3. Mesh Cap Cover Protects the mesh. 4. Mesh Efficient nebulisation is realized through the use of minute pores. Do not touch this fragile part with your fingers! Do not attempt to clean with a cotton swab or a pin! 5. Air port Stabilizes nebulisation. 6. Medication Port Medication can be filled here by opening the mesh cap. 7. Vibrator The tip of this vibrator oscillates at high frequency and pushes the medication through the pores of the mesh. 8. Medication container cap locking lever Opens the medication container cap. 9. Medication container cap To be opened for cleaning the medica- tion container.

Mesh cap viewed from the bottom

Figure viewed from the above

Viewed from the bottom

Page 5 of the Omron MicroAIR - U22 user manual — How to insert or replace the batteries
Page 5 · click to enlarge
Page 5

How to insert or replace the batteries

How to use the AC adapter

Omron MicroAIR - U22 — How to insert or replace the batteries diagram (page 5)
Fig. 4 · How to insert or replace the batteries

Using the AC adapter The AC adapter is an optional accessory.

1. Remove the battery cover by slightly rotating the disengaging lever in the direction of the arrow (1).

Place the main unit on the AC adapter connector. Press firmly untill it clicks.

2. Insert the batteries according to the battery polarity indicated inside the battery compartment.

Plug in the power plug of the AC adapter to the electri- cal outlet.

3. Replace battery cover by aligning tabs and, with your thumbs, push into place until it clicks.

To remove the AC adapter connector from the main unit, remove the power plug from the electrical outlet and unlock the AC adapter connector by pushing the buttons on both sides.

Battery life and battery replacement

The unit can operate with alkaline batteries or with nickel-metal-hydride (NiMH) rechargeable batte- ries. Depending on the capacity and condition of the batteries, the unit can operate upto 8 days on a set of batteries based on usage of 30 minutes a day.

  • When the battery low indicator (orange) flashes, the batteries should be replaced. Replace both batteries with new ones.
  • The (optional) AC adapter does not function as a battery charger; rechargeable batteries must be charged in an external battery charger.
  • Remove batteries if the unit is not in use for long periods. Failure to do so could result in damage due to battery leakage.
  • Batteries should be treated as chemical waste; disposal should be done at your retail store or at appropiate collection locations.

Inserting batteries

Page 6 of the Omron MicroAIR - U22 user manual — How to assemble the unit and fill the medication container
Page 6 · click to enlarge
Page 6

How to assemble the unit and fill the medication container

How to assemble the unit and fill the medication

Omron MicroAIR - U22 — How to assemble the unit and fill the medication container diagram (page 6)
Fig. 5 · How to assemble the unit and fill the medication con…

When using the unit for the first time or after not using it for a long period of time, clean and disinfect the medication container, mesh, mask adapter, mouthpiece and mask. Refer to page 15 for instruc- tions.

4. Fill the medication container as illustrated. The maximum capacity is 7 ml.
1. Insert batteries or use the (optional) AC adapter, see page 8 and 9.
2. Remove the medication container from the main unit. To do so, push on the release buttons on both sides. This will disengage the latch mechanism.

Medication container release Buttons

The mesh cap seals the medication bottle. Confirm if the cap is securely installed.

3. Remove the mesh cap by placing your thumb under the rim, gently pushing up, tilt the cap back until perpendicular
6. Install the medication container on the main unit

and lift straight up.

Hold the medication bottle as illustrated.

Lift up the Mesh Cap by placing your thumb under the rim.

Do not touch the mesh!

Page 7 of the Omron MicroAIR - U22 user manual — How to assemble the unit and fill the medication
Page 7 · click to enlarge
Page 7

How to assemble the unit and fill the medication

How to select the nebulisation mode

Omron MicroAIR - U22 — How to assemble the unit and fill the medication diagram (page 7)
Fig. 6 · How to assemble the unit and fill the medication
7. Install the mask adapter on the main unit

If you push the ON/OFF (O/ I) button and release within approximately 1 second, the unit nebulises in continuous mode. If you push the O/ I button again, the unit stops nebulisa- tion.

The green power indicator lights up during nebulisation.

If you hold the ON/OFF (O/ I) button for approx. 2 seconds or more, the unit nebulises in the manual nebulisation mode.

8. Install the mask or mouthpiece on the mask adapter

The unit only nebulises while you keep on pressing the O/ I button and stops nebulisation when you remove your finger from the button. In this mode, nebulisation may be synchronised with your Inhalation/exhalation cycle and medication waste is minimized.

The green power indicator lights up during nebulisation.

The device is now ready for use. Refer to the next section on how to select the nebulisation mode and how to inhale.

Continuous nebulisation mode · Manual nebulisation mode

Page 8 of the Omron MicroAIR - U22 user manual — How to inhale with the OMRON MicroAIR U22
Page 8 · click to enlarge
Page 8

How to inhale with the OMRON MicroAIR U22

How to clean the unit after each inhalation

!Caution: Only use type and amount of medications as prescribed and instructed by your doctor. 1. Slightly tilt the unit as illustrated in the figure. In this position, the vibrator is immursed in the medication and nebulisation will start after power on. After the vibrator has been immursed in the medication, the unit can be used under any angle. !Caution: In some positions (e.g. upright), nebulisation may stop after a short while. In that case, briefly tilt the unit again in order to re-immerse the vibrator in the medication. 2. Place the mouthpiece in your mouth or place the mask over mouth and nose. Always be calm and relaxed when you inhale. Breathe in slowly and deeply so that the medication can reach deep in to the bronchial tubes. Hold your breath briefly, then breathe out slowly while removing the mouthpiece from your mouth. Do not breathe too quickly. Pause when you feel like having a rest. You may synchronise the nebulisation with your inhalation/exhalation cycles by using the unit in ‘manual nebulisation mode’. Refer to page 13. Note: If high-viscosity medication is used, nebulisation may be reduced. If excessive medication collects on the mesh, nebulisation may stop. In that case, turn off the power and remove the mask adapter. Absorb the medication by means of a lint-free cloth. !Caution: Do not poke the mesh with a cotton swap or a pin; the mesh may be permanently damaged.Medication Vibrator Air Port Absorb the medication. Absorb the medication. After inhalation always switch off the nebuliser by pressing the O/ I button. When an AC adapter was used, disconnect the AC from the electrical outlet. 14

remain in the unit, causing risk of infection.

The following items should be cleaned after each use: Medication container, mesh cap, mask adapter, mouth- piece and mask.

1. Remove the mask adapter from the main unit. 2. Remove the medication container from the main unit:
3. Remove the mesh cap from the medication container, discard the medication and open the medication container cap. It is recommended to nebulize clean water to remove medication left in the mesh holes after discarding the medication.
4. Remove the mesh cover from the mesh cap.

!Caution: Do not touch the mesh.

Page 9 of the Omron MicroAIR - U22 user manual — How to clean the unit after each inhalation
Page 9 · click to enlarge
Page 9

How to clean the unit after each inhalation

How to disinfect the unit each day

5. Wash the parts (not the main unit!) in a warm soapy solution. Rinse the parts in warm tap water to remove the soap residue.

The medication container, mesh cap, mouthpiece, mask and mask adapter should be disinfec- ted

Some types of medications can easily remain on the mesh, therefore pay close attention during washing. Do not touch the mesh with a cotton swab, or with a pin.

  • before using the unit for the first time,
  • after the unit has not been used for a long period of time, or
  • daily during normal use.

Before disinfection, always first clean the parts as described in the section “How to clean the unit after each use” on the previous page. Disinfection of the individual parts can be done, using one of the following methods:

6. Shake off excessive water from the parts and let them air dry on a clean, lint free (paper) towel.
1. Disinfection by boiling. Note: Main unit, medication container and flexible mask can NOT be boiled. For these parts, use other methods, as described below. Mesh-cap, mouthpiece and mask-adapter can be disinfected by boiling in distilled water. After 10 to 30 minutes of boiling, shake off excessive water from the parts and let them air dry on a clean, lint free (paper) towel.
7. Clean the main unit and it’s electrodes by wiping it off with a (moistened) gauze. Use a dry gauze to wipe the main unit dry. Do not use volatile agents, such as benzene or thinner.

2. Disinfection by using alcohol. All parts can be disinfected by using alcohol. Note: Alcohol is highly flammable; do not use alcohol in close vicinity of open fire; do not smoke. Soak the parts (NOT the main unit) in 70% ethyl alcohol for approx. 1 minute. Shake off exces sive alcohol from the parts and let them air dry on a clean, lint free (paper) towel. Alternatively, disinfect all parts by wiping them off with a lint-free cloth, soaked in alcohol.

8. Assemble the unit, refer to page 10.
9. Store the unit in a dry, clean place.
3. Disinfection by commercially available disinfectant. Note: Do NOT soak the main unit in any disinfectant. Do not use disinfectant containing Sodium (Natrium) Hypochlorite; this may affect the metal parts. For disinfection of the parts, refer to the instructions as supplied by the manufacturer of the disinfectant. After disinfection, thoroughly rinse the parts with warm tap water. Shake off excessive water from the parts and let them air dry on a clean, lint free (paper) towel.
Page 10 of the Omron MicroAIR - U22 user manual — How to replace the mesh cap
Page 10 · click to enlarge
Page 10

How to replace the mesh cap

Troubleshooting

TroublePossible causeCorrective action The nebulisation rate is extremely lowBatteries are low (the orange battery low indicator flashes).Replace the batteries with new ones. Refer to page 8. The mesh is stained or clogged.1. Clean the mesh by boiling. Refer to page 15. 2. Replace the mesh cap with a new one. Refer to page 10. The green power indicator does not turn on and the unit does not nebulise.The green power indicator does not turn on and the unit does not nebulise.The batteries are low.Replace the batteries with new ones. Refer to page 8. The capacity of rechargeable batteries is low.Charge the batteries with a commercially available recharger. The batteries are inserted in the wrong direction.Re-insert the batteries in the correct direction. Refer to page 8. The AC adapter is not correctly connected to the main unit.Remove the AC adapter from the main unit and connect it correctly. The medication container is not installed correctly to the main unit.Remove the medication container from the main unit and install correctly. Refer to page 11. The green power indicator turns on but the unit does not nebulise.The vibrator is not immursed in the medication.Tilt the main unit in order to immerse the vibrator in the medication. The medication container is not filled with medication.Fill with medication. Refer to page 11 The mesh is broken.Replace with a new one. Refer to page 10.

The mesh cap is a consumeable part.

Omron recommends to exchange the mesh cap after approximately 1 year. In case the unit nebulises poorly even after boiling in water (refer to “Disinfection by boiling”), replace the mesh cap. Remove the mesh cap and install a new one as described on page 10 (section “How to assemble the unit and fill the medication container”).

Page 11 of the Omron MicroAIR - U22 user manual — Troubleshooting
Page 11 · click to enlarge
Page 11

Troubleshooting

Specifications

Trouble Possible cause Corrective action

This device complies with the provisions of the EC directive 93/42/EEC (Medical Device Directive).

Medication or water has collected on the electrodes on the main unit.

The green power indi- cator turns on but the unit does not nebulise.

Remove the medication or water. Refer to page 15.

Product name: Electronic mesh nebuliser Model name: OMRON NE-U22 Power source: 3 VDC (two alkaline penlite batteries/Type AA/LR6) 2.4 VDC (two NiMH rechargeable batteries) AC adapter (optional) 230 VAC, 50 Hz Power consumption: Approx. 1.5 W Ultrasonic frequency: Approx. 180 KHz Nebulisation rate: Average 0.4 - 0.5 ml/minute* Particle size (MMAD)**: Approx. 5 µm* Capacity of the medication container: 7 ml max. Residual volume: approx. 0.1 ml External dimensions: Approx. 38 (W) x 104 (H) x 51 (D) mm Weight: Approx. 97 gr (excl. batteries) Battery life: Approx. 8 days (30 minutes each day) Operating conditions: 10˚ ~ 40˚C, 30%~85% RH

Excessive medication is collected on the mesh

Remove excessive medication. Refer to page 17.

If the unit does not nebulise properly after checking the possible causes above, contact your OMRON dealer.

Replacement parts and accessories:

Meshcap: P040014 AC-adapter: A040004 Flexible adult mask: A040002 Flexible child mask: A040003 Mask adapter: P040015 Mouthpiece: P040016 Main unit cover: P040012

Contents of the package: Main unit, main unit cover, medication container, mesh cap, mask adapter, mouthpiece, flexible child mask, flexible adult mask, 2 batteries (AA/LRG), instruction manual, warranty card, soft pouch

*Values measured with 0.9% NaCl solution and under temperature of 23˚C; specifications may vary with medication used and environmental conditions. **MMAD: Mass Median Aerodynamic Diameter. MMAD is independantly measured at Bradford University, UK, Dr.John Dennis, according to the European nebuliser standard EN13544-1. Documentation and/or specifications subject to change without prior notification.

EU-representativeOMRON Healthcare Europe B.V. Kruisweg 577 2132 NA Hoofddorp

Read the instruction manual carefully

=class ll · =Type B · O/I =power off/on

Page 12 of the Omron MicroAIR - U22 user manual — Gebrauchsanweisung
Page 12 · click to enlarge
Page 12

Gebrauchsanweisung

Omron MicroAIR - U22 — Gebrauchsanweisung diagram (page 12)
Fig. 7 · Gebrauchsanweisung
Omron MicroAIR - U22 — Gebrauchsanweisung diagram (page 12)
Fig. 8 · Gebrauchsanweisung
Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
The nebulisation rate is extremely lowBatteries are low (the orange battery low indicator flashes).Replace the batteries with new ones. Refer to page 8. p.10
The nebulisation rate is extremely lowThe mesh is stained or clogged.1. Clean the mesh by boiling. Refer to page 15. 2. Replace the mesh cap with a new one. Refer to page 10. p.10
The green power indi- cator does not turn on and the unit does not nebulise.The batteries are low.Replace the batteries with new ones. Refer to page 8. p.10
The green power indi- cator does not turn on and the unit does not nebulise.The capacity of rechargeable batteries is low.Charge the batteries with a com- mercially available recharger. p.10
The green power indi- cator does not turn on and the unit does not nebulise.The batteries are inserted in the wrong direction.Re-insert the batteries in the correct direction. Refer to page 8. p.10
The green power indi- cator does not turn on and the unit does not nebulise.The AC adapter is not correctly connected to the main unit.Remove the AC adapter from the main unit and connect it correctly. p.10
The green power indi- cator does not turn on and the unit does not nebulise.The medication container is not installed correctly to the main unit.Remove the medication container from the main unit and install cor- rectly. Refer to page 11. p.10
The green power indi- cator does not turn on and the unit does not nebulise.The vibrator is not immursed in the medication.Tilt the main unit in order to immerse the vibrator in the medica- tion. p.10
The green power indi- cator does not turn on and the unit does not nebulise.The medication container is not filled with medication.Fill with medication. Refer to page 11 p.10
The green power indi- cator does not turn on and the unit does not nebulise. p.10
The green power indi- cator does not turn on and the unit does not nebulise.The mesh is broken.Replace with a new one. Refer to page 10. p.10
Medication or water has collected on the electrodes on the main unit.Remove the medication or water. Refer to page 15. p.11
Excessive medication is collected on the meshRemove excessive medication. Refer to page 17. p.11

Ask about the Omron MicroAIR - U22

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Omron MicroAIR - U22

Be the first to ask — other owners or our team will answer.