MAC A 300/400 CONTROL Application The MAC A 300/400 is an engine control designed for controlling one or two engines (max. 500W) for swing gates, sliding gates, garage door openers, barriers and shutters. The control is equipped with phase cut and force setting. Partial editing makes it possible to print the price of versions without phazean cut and power off or only offer one engine.


MAC A 301 1 wing without phazean cut and force control. MAC A 302 2 wings without phazean cut and force control. MAC A 401 1 wing with phazean cut and force control. MAC A 402 2 wings with phazean cut and force control. Operating voltage: 230V AC +/- 10% Frequency: 50 Hz Operating temperature: -20°C / +50°C Storage temperature: -10°C/+80°C Dimensions (WxHxD): 175 x 253 x 78 mm Setting and operation - All settings are determined by a 16 position / 16 menu selector. The
set values are increased or reduced by two push buttons and can be read through a double 7 segments LED. - In position "0" or if the selector or control buttons are set for 10 seconds
The position of the engines and doors shall be indicated. When using the selector switch or setting buttons, the LED returns to the selected menu. In normal operation, the selector switch shall be in position "0." - If the selector switch is placed in a new position, then the display will last for 1 sec.
Display the number/letter of the selected menu. Then the set value is shown. - The setting buttons allow the desired values to be used within the set limits
be set within one menu. - Any change is stored immediately in memory and if power failure remains the
The Commission is also proposing to maintain the values. - From the moment of change in value, the control immediately works with the new
value. - A test pressure key parallel to the impulse switch is located in the control field. - If both selectors are pressed together with the test pushbutton for more than 3 seconds, then
returns the microprocessor to factory settings completely. During resetting, the 7 segments of LED will pink. The transition from pinks to permanent fires indicates the end of the full reset procedure. - If both selectors are briefly pressed together with the test push button (1 sec.), then a
partial reset executed while maintaining the set values.
- The functions per menu of the generations ACM20 V1.8 (1-v/eugelig) and ACM 20 V2.8 (2-wingy) are shown in the following table. -




FUNCTIONS General - The control is done via a microprocessor. - The number of movements in open loop is recorded in an internal memory for service
purposes. - Operation without an end-of-run switch is possible.
The end-of-life shutdown will then be done either by power cut or on maturity. - By connecting the inputs IMPULS, STOP, OPEN, TOE and SOME
FLUUGEL can control multiple motor controls with only one receiver I external impulser. - On a second plug-in foot (A) the function OPEN /
STOP(kan.3) / TOE(kan.4) / IMPULS (kan. 7) or SOME FLOWER (can be awarded). Stop does not have an emergency stop function here! - After the mains voltage is installed, the control starts to work with the door position of front
The power voltage failure. - After the first order, the gate should normally "OPEN." However, the engine was on the
The maximum speed of the vehicle shall be at least 1 km/h. - There is always a delay of 0.5 sec. If a change is made to an immediate
prevent rotation of the direction of movement (risk of machinery breakage). After a standstill of more than 0,5 sec. start the engine immediately - The command for an OPEN loop shall be:
* The warning light and the normal light are lit immediately * After the prewarning time (menu 9), the electric lock is drawn and engine 2 starts. * 1 sec. Engine 1 will start later. * After the start time (menu 4) the electric lock is no longer drawn. * The power limit is only activated after the start time (menu 4) of the respective engines. * When the limit switch is reached, after expiry of the duration or by power cut-off, the engine stops immediately. * The warning light will be switched off as soon as both engines are at their end point. * The light remains on for as long as it is set in menu A after the last motor movement. - The order for a DISTANCE loop shall be:
* The warning light and the normal light are lit immediately. * After the warning time (menu 9), the electric lock is pulled and engine 1. * After the closing delay (menu 7), engine 2 starts. * The power limit is only activated after the start time (menu 4) of the respective engines. * When reaching the limit switch, after expiry of the time or by power cut-off, the engine stops immediately * The warning light is switched off as soon as both engines are at their end point. * The light remains on for as long as it is set in menu A after the last motor movement. - If the engine is blocked immediately at start, e.g. the electrical lock not properly unlocked
is, then the engine returns with drawn electric lock and demands a start again under full voltage.

Duration - The maximum duration can be set per engine of 0.98sec. in steps of 1 sec or on
3 min (Menu 5 for M 1, menu 6 for M2) - In dense loop the duration automatically is approx. 1 sec. more than in open walk, to be sure
of a good closure if no electric lock is used. - If the duration of M2 (menu 6) is set to "00," then the control will be used for 2
engines are a control for 1 engine. Of course, menu 3 (force M2) and menu 7 (pocket delay M2) should be then on . The Commission's proposal is therefore not acceptable. Automatic closing - The open hold time (menu 8) is by any OPEN, STOP, NEED TOP or FOTOCEL command
reset and starts running again from engine failure, if at least one wing is not located at the end of the closed loop. - The automatic shut-off works, if both engines, or only the separate wing to operate, on
the end of the OPEN loop remains standing. - When selecting a function for the photocell input (menu C = "8,9 of 10.10.1993) close the wings
automatic 0,5 or 3 or 7 sec after a photocell detection, independent of the set open-keeping time for the auto-closing. During the opening process, the photocell will not function if the port is completely open after 0.5 or 3 or 7 sec. an automatic closure. During the closing process, this setting follows a loop with automatic closure after 0,5 or 3 or 7 sec. When the gate is fully open. - In position 8 of menu B can (e.g. by means of a clock) the automatic shut-off via "stop entrance"
turn on/off. In case of closed contact (red LED is lit), the automatic shut-off is switched on. Power Off - The effective engine current (range of 0... 3,5A) is measured per engine.
The maximum flow rate per direction of rotation is taught during the first movement. If the following movements exceed this current value + the set added value (menu 2 for Ml, menu 3 for M2) then a power shutdown is followed. - According to the set function (menu D), when power-off of an engine is switched off in OPEN or
Towards immediately a STOP, limited runback or runback of both engines. - In the first 2 seconds. the time period set (menu 5 or 6) follows a
power shutdown only a STOP, just as no limited decline or return occurs during the end run. This is contrary to a barrier during the journey, where there is a limited return. - The switch-off delay is approx. 0, 1 sec. - After the power cut-off run at STOP or limited downrun, engines, on a subsequent
IMPULS command, away from the obstacle. - During the limited decline of at least 2.0 sec. Following a power-out only one
STOP to prevent the gate from going back and forth when it is clamped.

- If an engine is switched off by force, this will be indicated on the display until it reaches its speed limit.
Next order. This is how it can be recognized or e.g. One wing at the end was switched off by time or force through the limit switch. - During operation, the control shall check whether the flow of the engines is measured.
If not, the electronics may be defective for measuring current. The alarm message "E 1" for engine 1 and "E2" for motor will appear on the display. The control is then locked internally and no longer accepts orders. A reset can be done after simultaneously pressing the keys "+," "-" and "Test," or following a power cut. - If menu 2 (force M 1) or 3 (force m2) are set to "00," then this is the same
engine no power shutdown. There are therefore no error messages "E1" or "E2" when no engine is connected. Power supply engine / voltage control - During the run-up of the first motor, the voltage is automatically from 60V to 230V
evenly elevated to avoid a swing of heavy gates. - During operation, the voltage for both engines can be within a range of 50V to 230V
The Commission has also proposed to reduce the amount of electricity in question by a further reduction, which would allow for a clearer change in current due to an obstacle and limit maximum power during the loop. - At the start of the 2nd engine, during the run-in time the reduced voltage is returned to
230V and then reduced back for both engines.
INDICATION OF THE LEDS - On the circuit board are three yellow LEDs indicating LIGHT, WARNING SIGNAL
and ELEKTRISCH SLOT present. - Immediately behind the terminal, the following LEDs are arranged which have a
Please indicate the approved entry:
Impulse input yellow Open-in yellow Stop entry red Close-in Yellow Photocell entrance red End-in switch-in-all M1 green End-out switch-open-input M1 Green End-switch-intake M2 green End switch-out-open M2 open-ingress M2 Green Entrance when operating single wing yellow

ENTRIES Impulse input for pushbutton, key contact, code keyboard, external receiver The IMPULS input (clamps 25/26) can be connected to a potential-free N.O. contact. The TEST / IMPULS tester on the circuit board also works at this input. An IMPULS receiver command can be connected to these clamps and linked parallel to a second control. Function:
Main function . . Out-Stop-Dicht-STOP-Out-en. Order with door closed in position . . Open walk Order during open run . Next order . . Ditch loop Order with door in position open . Ordered during closing . . Stop. Next command . . Openloop When operating the OPEN or FICH Pulse Gather, an IMPULS input has no effect, when controlling STOP or FOTOCEL input only a stop function is used. The impulse input can also be connected to a code keyboard, clamp 25 is equipped with an AC voltage of +20V. Open-in for pushbutton, external receiver The OPEN input (clamps 26/27) can be connected to a potential free N.O. contact. An OPEN receiver command can be connected to these clamps and linked parallel to a second control. Function: Select mode of operation open loop: impulse or holding contact (MENU E) With continuous impulse from the Open-input, the door remains in open condition. Partial opening of doors: Can be set to menu point F. Order with door closed in position . . In an OPEN order, the door opens for time set in menu point F. Next command .The door opens again according to the set time. Partial opening is suitable as a passenger entrance and to prevent heat loss in winter. Stop-in for pushbutton, external receiver The STOP input (clamps 28/29) can be connected to a potential free N.O. contact. A STOP receiver command can be connected to these clamps and coupled parallel with a second control. Function: The STOP input function can be determined with menu B. The following possibilities exist for the open and closed loops. STOP: Both engines stop immediately At the next command, a loop in the opposite direction follows. Limited rundown: The running engines stop and run after 2,Os. in the
opposite direction. At the next command, engines will go back in their original direction. Retroversion: The running engines stop and run in the opposite direction until
At their final destination. If the STOP is permanently confirmed, an IMPULS start can be made!

NOTE: The STOP entrance is not a safety entry (no emergency stop)! Accessory for push button, external receiver At the TOE input (clamps 29/30) a potential free NO contact can be connected. A TOO receiver command can be connected to these clamps and linked parallel to a second control. Function: Select control mode closed loop: impulse or contact (MENU E). If the TOE entrance is pushed on, the door will remain in a closed position. Photocell input At the photocell entrance (clamping 31/32) a potential free N.C. contact. If this entry is not used, it must be covered. The photocell input can also be used to connect a safety strip and thus has a security function. The entrance is constantly checked through a Diagnosis system. If an error is detected in this circle, then there will be an alarm ("E3" on the display). A further operation is then no longer possible. Function: The function of the photocell input can be determined with menu C. In open and closed loops there are following possibilities. No operation: No change in engine condition. If a photocell is activated, no start can be made for security reasons. Stop: Both engines stop immediately At the following command, the motors run in the opposite direction. Limited rundown: The operating engines stop and then walk 2.0 sec in the
The opposite direction. Retroversion: The working engines stop and then run in the opposite direction until their final course. At constant impulse on the entrance, no engine start is possible. Close: The port automatically closes 0.5 or 3 or 7 sec. after leaving the photocell(len). Emergency stop entrance for emergency stop, door contact At the emergency stop entrance (clamps 33/34) a potential N.C. contact. If this entry is not used, it must be covered. With this emergency stop entrance, the coils of the motor relays are also directly switched off. (safety function). The LED "ES 7" and "ES2" lights up at the same time. Function:
If ordered during engine operation, a stop shall be immediately followed. At the next command (impulse) a movement follows in the opposite direction. End switch inputs At the limit switch inputs, various types of end switches with potential free N.C. contact. If this entry is not used, it must be covered. The power switch inputs also switch off the engine relays. (safety function). Clamps 35/36: Endsch. 1 Close Clamps 36/37: Endsch. 1 Open Clamps 38/39: Endsch. 2 Clamps 39/40: Endsch. 2 Open

Function:
When ordered in open loop, only the limit switches work open, at close walk only the end switches. There's a stop coming right up. The next command (impulse) is removed from the limit switch. When an engine is on its end-out switch, no motor start is followed in the direction of the end-of-run switch. Single-wing input: for partial control of M2 At the single wing entrance (clamps 41/42) a potential free N.O. connect contact. A single wing-receiver command can be connected to these clamps and coupled parallel to a second control. A single wing command is only accepted if the engines M 1 and M2 are in position TOE. If the single wing is on its path or at its end run OPEN, then an IMPULS- or OPEN-command M 1 can be opened. Function: Basic function . . Open -Stop -Toe -Sstop -etc. However, only for M2 Order at gate . . Following order . . close command at gate open . Ordered during closing stop . Next order, open walk.
EXITS Electrical lock-out for connection of an electrical lock or auxiliary relay for
other purposes With a jumper in the control field you can choose between an electric lock of 12 V AC; max. 1 A or 24 V AC; max. 0.5 A. The connection is done to clamps 22/23. Function:
The electric lock is always controlled over a relay during the lead time (Menu 4) at the start of M praise M2 in open and closed loop. Light output for garage lighting etc.
At the light input (clamps 13/14) can directly an illumination of 230V. up to 500W. Function:
The lighting shall be controlled over a relay during the warning time, during the engine run and after each running for the period set in menu A. If menu A is set to 61, then the light output has a port position function. If you connect a 230V signal lamp, for example. the port position to a doorman is reported without any higher expenditure.
Door closed: Light out of Door runs: Light to Door in position: Light at Door stands still on the path: Light on or operate single wing

When menu A is set to 62, a short impulse at the light output will follow with each engine start. This is how we can, for example. with an extra stairwell light machine a longer lighting time are started. Warning light output for connecting warning lights, flashing lights etc.
At the warning light output (clamps 14/15) you can directly a 230V lighting of max. 500W. Function:
The warning light shall be controlled over a relay during the pre-warning time (menu 9) and during the engine run.
Value of 00...70 .. permanent warning light with 0.. 70s. engine start warning. Value of 11...20 . . permanent warning light with 1...10s. for engine start warning in a closed direction. 24 V AC output as power supply for external controllers
At the 24 V output (clamps 23/24) can be 24 V AC. max. 200mA are taken for the feeding of external commandors such as photocells. This output is additionally protected with fuse Si 3 CT 200 mA) 230 V AC output as power supply for external command
230 VAC max. 1 A are taken for the power supply of external controllers such as photocells and also control lamps. This output is protected just like the joint control with the mains fuse Si 1 CT 5 A) 230 V AC connections
Clamps 1...4 : Earthing of grid and drives Clamp 5/6 : Condensator M1 Clamping 7/8 : Kondensators M2 Clamp 16 : Dicht M1 Klem 17 : Open M1 Clam 18 : Common M1 (max. 500W) Clamp 19: Common M2 (max. 500W) Clamp 20: Close M2 Clamp 21: Open M2
PLUG-IN FEET Plug-in feet receiver: for the 1-channel receiver Function: impulse effect Plugging foot receiver A: for a second 1 channel receiver
With a jumper SL 2 you can choose between the functions IMPULS / OPEN / STOP / VICTIM or SINGLE FLOW. Plug-in foot B: for one track control or print red/green light

PLACING IN SERVICE OF ELECTRO-MECHANICAL ENGINES 1). Engines with a large variation in power consumption. - Tension. - Set menu 5 (timeline) to a time that is definitely smaller than in Time required to complete the
to continue. The values in menu . . are reduced to value 1. - Check the correct connection of the engine. (first movement = open). - Set the menu . . (engine voltage) to value so that the engine can open and close the port. - Then step by step in increase maturity until in engine exactly the entire route
The Commission has already taken a decision on the matter. (The steering measures in recorded engine flow during the journey up to 2 sec. before the end of the journey). - In menu . . 1 . in set value with 1 unit and then bring them
back to its original value. (increase by 1, then reduce by 1) - The engine is allowed to pass the entire route (open and closed).
The current is now measured over the entire trajectory and the maximum value is remembered. The engine will be stopped on time during this measurement phase. - The engine is again driven along the entire route. This time the engine stops on power.
This is shown on the display (LED flashes). - Last but not least, the increases are set at maximum. measured current in (menu 2 and 3) so that the
gate stops at desired counter-force. 2). Engines with a weak variation in power consumption. (e.g. MAC Twister, MAC Metro, MAC Swing) - Tension. - Place the menu . . and . - Check the engine connection (first movement = open). - Set the power (engine voltage) by means of menu . .

PLACING IN SERVICE OF ELECTRO-HYDRAULIC ENGINES - There is no power control in the steering cabinet. - These engines only operate on maturity. - The power adjustment is done on the engine itself.
FUSES AND PROTECTIONS OF THE INSTALLATION - fuse 1 (T5A) directly shields the power supply. - Fiber 2 (T800mA) shields the internal logic and plug-in feet. - fuse 3 (T200mA) shields the 24V AC output. - The engine shutdown is done equally over a relay and additionally with a Triac
in the circle of phazean cut. - Light and warning light are switched off on a relay. - The transfo (12V A) has internal thermal fuse that is at too high a temperature
Disables. - The emergency stop entrance immediately switches off all motor relay coils. - The end-of-run switch inputs immediately disable the corresponding motor relay coils. - The 230V AC controlled components have, even when plugged in printing, a free space
min. 8mm. - The touch fuse of the main circuit board and the plugged-in printing is in a housing.
MALFUNCTIONS/ CE CHARACTER The CE rules in force in Europe in 1996 have been complied with. The faults of the microprocessor and engine control components do not affect the range of the receiver.
HOUSING - Plastic housing, protection degree IP65 (dust and splashproof), 225 x 176 x 78mm. - There's an alu inside. profile for mounting 2 motor candle holders, max. D = 35mm,
L = 82mm. - Dimensions of the electronics (with stitch cards) without housing, 165 x 234 x 70 mm.