Lynx Studio Technology, Inc.



The following typographic conventions are used in this manual: ¾ ALL UPPER CASE TEXT refers to a specific parameter selection control (i.e. SYNC SOURCE) or a cable
connection.
¾ Text in quotation marks indicates a parameter selection value or menu option (i.e. “EXT”).
¾ Phrases, such as: Start > Programs > Lynx Studio Technology use the greater than symbol (“>”) to indicate
multiple menu options or mouse selections within a software control context. 5 Warranty Registration
We are committed to providing you with the best service possible. To help us serve you better, please be sure to register your LT-ADAT using one of the following methods:








9. Plug in and power up the Aurora using the front panel standby switch. If the green LED on the LT-ADAT lights up, proceed to step 10. If the LED does not light, unplug Aurora and check the cable connections to and from the LT-ADAT. Then plug in and power up again. If the green LED still does not light, contact Lynx Customer Support. 10. Remove the power cord from Aurora and reinstall the Aurora top panel using the eight screws. Do not over tighten the small screw near the center of the front faceplate as it is easily damaged.

The photo below details LT-ADAT connectors.

The LT-ADAT provides two ADAT optical inputs and outputs. They are labeled on the mounting bracket and in the figure above. The ADAT channels corresponding to each port are as follows: IN 1 ADAT input channels 1-8 OUT 1 ADAT output channels 1-8 IN 2 ADAT input channels 9-16 OUT 2 ADAT output channels 9-16 Connect the LT-ADAT to ADAT devices in your system using standard ADAT compatible (Toslink) fiber optic cables. Refer to the “Optional Equipment” section at the beginning of this manual for part numbers of cables available from Lynx. .

After installation, the Aurora will need to be configured to send and receive signals from the LT-ADAT. Signals from the ADAT inputs can be delivered to the analog and/or digital outputs of the Aurora, and signals from the Aurora’s analog or digital inputs can be routed to the LT-ADAT outputs. This routing can be established globally from the Aurora front panel or on a per-channel basis from the Aurora External Control Software. The External Control Software can be used with a PC or Macintosh computer equipped with a Lynx Audio Interface, MIDI Interface or Infrared transceiver. For more information, please consult the Aurora External Control manual. Front panel routing affects all 16 LT-ADAT channels, which are mapped to directly corresponding Aurora channels (i.e. In 1 to Out 1, In 2 to Out 2, etc.). Port 1 provides channels 1-8, Port 2 provides channels 9-16.
To route signals from the LT-ADAT inputs to the Aurora analog
outputs, select “LSLOT IN” as the signal source from the TO
ANALOG OUT selection button.
To route signals from the LT-ADAT inputs to the Aurora digital
outputs, select “LSLOT IN” as the signal source from the TO
DIGITAL OUT selection button.
When routing from the front panel, signals sent to the digital outputs
are sent simultaneously to the LSLOT outputs. To choose the signal
source to be routed to the LT-ADAT outputs, select the appropriate source with the TO DIGITAL OUT button. Note: When “LSLOT” is
chosen here, signals from the LT-ADAT inputs will be routed to the
LT-ADAT outputs as well as the AES/EBU digital outputs.
In any system with more than one digital device, there can be only one master clock providing synchronization to all connected devices. Devices connected to the LT-ADAT can slave to the sample clock from the Aurora, or they can be configured as clock masters providing sample clock that the Aurora can slave to. It is also possible to have a separate clock source that provides clock to both the Aurora and Lightpipe device(s). The essential thing is that all devices synchronize to a single source. Please see section 2.4 of the Aurora manual for information about available clock settings with the Aurora. If you choose to have the ADAT Lightpipe device(s) be clock slaves, in most cases they can be set to receive clock from their ADAT optical inputs, or via wordclock. Even if the Aurora is configured to slave to some other clock source, valid, low-jitter clock is presented to its Wordclock and LT-ADAT outputs. See the documentation for the ADAT Lightpipe device to determine how to change its clock source (most devices default to Internal). The Aurora can also slave to the clock signal from the LT-ADAT inputs. To do so, simply choose “LSLOT” with the SYNC SOURCE button on the Aurora front panel, and make sure that the ADAT Lightpipe device is operating off of its Internal clock.

The figures below detail three common clock schemes: 9.1 Aurora as clock master, ADAT device slaves to wordclock

Aurora SYNC SOURCE: INT ADAT Device Clock Source: Wordclock 9.2 Aurora slaves to ADAT device via Lightpipe connection

Aurora SYNC SOURCE: LSLOT ADAT Device Clock Source: Internal 9.3 Aurora and ADAT device slave to house clock



S/MUX is enabled on demand, based on the current sample rate currently selected for recording or playback. As such, the mapping of channels will change when the sample rate changes. The user must be keenly aware of this “automatic” re-mapping to avoid mixing and routing problems. When the Aurora has the SYNC SOURCE set to LSLOT, the LT-ADAT cannot determine if an incoming signal is using S/MUX. Because of this, the user must manually set the SAMPLE RATE on the front panel of the Aurora to match the sample rate of the ADAT device.

Number / Type Two inputs and two outputs, compatible with Alesis ADAT Type I and Type II Optical Digital Interface Protocol, up to 24-bit data Channels 16 @ 44.1kHz 48 kHz sample rates 8 @ 88.2 kHz and 96 kHz sample rates, S/MUX enabled 4 @ 176.4 kHz and 192 kHz sample rates, SMUX enabled Input Receiver Fast-locking phase-locked loop with 30 kHz to 55 kHz lock range CLOCK SYNCHRONIZATION
Clock Sources Aurora, Optical In 1 ARCHITECTURE
Core FPGA-based core. Support for field upgrades of firmware. Routing/Mixing Integrates with Aurora’s digital mixer to allow independent routing of ADAT I/O with onboard analog and digital I/O. CONNECTIONS
I/O Ports (4) Bracket-mounted TOSLINK connectors. Other LStream interface headers GENERAL
Host Interface Lynx LSlot proprietary LStream™ Interface: 24.5 Mbps bi-directional Requirements Aurora 16/Aurora 8 with Firmware Revision 12 or higher and available LSlot expansion slot. Size 3.0” H X 5.0” W X 0.75” D EMI Certifications FCC and CE Shipping Weight 2 pounds

We are devoted to making your experience with the LT-ADAT trouble-free and productive. If the troubleshooting and operational sections of this manual did not help resolve your questions, several support options are available to you: 12.1 Lynx Website Support Resources Logging on to http://www.lynxstudio.com/support.html will provide several options for resolving your support issues: Support Ticket
For direct attention from the Lynx Technical Support Staff, registered users can submit a support ticket online that details their problem and steps they’ve taken to resolve it. Most Support Ticket submissions are responded to within 24 hours. Frequently Asked Questions
An extensive catalog of FAQs derived directly from our most common tech support inquiries. Our FAQ section is updated regularly and designed to allow users to find the answers to their most common questions quickly. Firmware and Driver Downloads
A library of current firmware and driver files are available for download and installation. Check back regularly to insure that your Aurora is up-to-date. Lynx Support Forum
An online Lynx users support forum provides a venue for customers to post questions and issues and receive responses from other users as well as Lynx technical administrators. Searching previous posts is often an excellent way to uncover valuable information about Aurora operation and troubleshooting. See http://www.lynxstudio.com/forum 12.2 Telephone Support Telephone support is available by calling +1 (949) 515-8265 extension 206 from 9AM to 5PM Pacific Time, Monday through Friday, excluding United States Holidays. 12.3 Registering your LT-ADAT Lynx is committed to providing you with the best service possible. To help us serve you better, please be sure to register your LT-ADAT using one of the following methods: ¾ Fill out and mail the Warranty Registration Card included with your Aurora. ¾ Register on the web at: http://www.lynxstudio.com/support.html
Once you are registered you will automatically receive notifications of new products and upgrades. 12.4 Return Policy If you have a unit that you suspect is defective or is malfunctioning contact Lynx technical support via one of the means described above for diagnosis. If the technician determines that the unit is faulty, they will issue an RMA number so you can send the unit in for repair. Units received without a valid RMA number will be refused. All RMA numbers are valid for 30 days from the date of issue.

Owners and our team usually reply within a day — and your question helps the next person too.