Read the operating instructions and the enclosed brochure “Guarantee and additional notices“ completely. Follow the instructions they contain. Safely keep these documents for future reference. !
Multimeter for taking measurements in the range of overvoltage category CAT III up to max. 300 V. The multimeter can be used to measure DC and AC voltages, direct current, battery charge status, resistance and check diodes within the specified ranges.
Hazardous electrical voltage warning: Unprotected live components inside the device housing may pose a risk of electric shock.
Protection class II: The test device has reinforced or double insulation.
Overvoltage category III: Equipment in fixed installations and for applications where specific requirements with regard to the reliability and availability of equipment have to be met, e.g. circuit-breakers in fixed installations and devices used in industrial applications which are permanently connected to the fixed installation.


Observe the technical safety regulations for working on electrical systems, especially: 1. Safely isolating from power supply, 2. Securing to prevent system being switched on again, 3. Checking zero potential, two-pole, 4. Earthing and short- circuiting, 5. Securing and covering adjacent live components.



V DC / V AC 300 V DC, 300 V AC
A DC 10 A DC (> 2 A max. 10 seconds every 15 minutes)
To replace the battery or fuses, first disconnect the test prods from their voltage source and then from the device. Undo all the screws at the rear of the device and replace the battery or replace the defective fuse by a fuse of the same type and rating. Do not touch the green pc-board. Also make sure it is kept clean. Close the housing and carefully screw the meter back together. Do not switch on the device with the cover open.

1 F 250 mA / 300 V (Ø 5 mm x 20 mm)
2 F 10 A / 300 V (Ø 5 mm x 20 mm)
3 1 x 9 V NEDA 1604 / IEC 6F22


The black test prod (–) must always be connected to the "COM socket". When taking current measurements > 200 mA the red test prod (+) must be connected to the "10 A socket". For all other measuring functions, the red test prod must be connected to the "VmAΩ -socket".

Before measuring, make sure that the test prods are connected correctly as the built-in fuse could otherwise trip and damage the measuring circuit. !
If the value of the measured variable is not known in advance, set the rotary switch to the highest measuring range or use the 10 A connection with the 10 A measuring range to measure current. Then reduce the measuring range step by step until a satisfactory resolution is achieved.
To measure voltage, set the rotary switch to the " " position with the corresponding measuring range (200 mV - 300 V).
Then connect the measuring contacts to the object to be tested. The measured value acquired and the polarity appear on the display.



To measure voltage, set the rotary switch to the " " position with the corresponding measuring range (200 V / 300 V).
Then connect the measuring contacts to the object to be tested. The measured value acquired appears on the display.

To measure current, set the rotary switch to the " " position with the corresponding measuring range (2,000 μA - 10 A). Ensure that the test prods are connected correctly.
2,000 μA - 200 mA = VmAΩ -socket > 200 mA - 10 A = 10 A-socket
Disconnect the circuit before connecting the meter. Then connect the measuring contacts to the object to be tested.

The measured value acquired and the polarity appear on the display. Disconnect the circuit again before disconnecting the meter.


Do not measure currents above 2 A for longer than 10 seconds within 15 minutes. This could damage the device or the test prods.
Current above 200 mA must not be measured in the μA / mA range and currents above 10 A must not be measured in the A range. Otherwise the corresponding built-in fuse will trip (F 250 mA / 300 V, F 10 A / 300 V, Ø 5 mm x 20 mm). !
To measure the battery charge status, set the rotary switch to the "BAT." position with the corresponding measuring range.
1.5 V = 1.5 V round cells / AA, AAA, C, D 1.2 V round cells (NiMH) / AA, AAA, C, D
9 V = 9.0 V flat cells / E-block
8.4 V flat cells (NiMH) / E-block
Then connect the measuring contacts to the battery.

The battery voltage is shown on the display. You can read off the battery charge status from the following scale.
Good: battery fully charged Weak: battery is weak and will soon need replacing Replace: battery is flat and should be replaced


1500 1400 1300 1200 1100 1000 900 800 700
9.0 8.3 7.6 6.9 6.2 5.5 4.8 4.1 3.4
1200 1130 1060 990 920 850 780 710 640
8.4 7.9 7.4 6.9 6.4 5.9 5.4 4.9 4.4
To test the diode, turn the rotary switch to position " ".
Then connect the measuring contacts to the diode. The measured value acquired for the forward voltage appears on the display.
If "1" appears on the display instead of a measured value, the diode has either been tested in the reverse direction or is faulty. If 0.0 V is measured, the diode is faulty or a short-circuit has occurred.


To measure resistance, set the rotary switch to the "Ω" position with the corresponding measuring range (200 Ω - 2,000 kΩ).
Then connect the measuring contacts to the object to be tested. The measured value acquired appears on the display.
If "1" appears on the display instead of a measured value, either the measuring range has been exceeded or the measuring circuit is not closed or has been interrupted.
Resistances can only be measured correctly in isolation; therefore, the components might need to be disconnected from the remainder of the circuit.
When measuring resistance, to avoid the risk of the results of a measurement being distorted, there must be no traces of dirt, oil, solder spray or other contamination on the test prods. !

Max. input voltage 300 V AC / DC
200 mV ± (0.5% rdg + 5 digits) 2,000 mV ± (0.8% rdg + 5 digits) 20 V 200 V 300 V ± (1.0% rdg + 5 digits)
AC voltage 200 V ± (1.2% rdg + 10 digits) 300 V
2,000 μA ± (1.0% rdg + 5 digits) 20 mA 200 mA ± (1.2% rdg + 5 digits) 10 A ± (2.0% rdg + 5 digits)
1.5 V round cells / AA, AAA, C, D 1.2 V round cells (NiMH) / AA, AAA, C, D 9.0 V flat cells / E-block 8.4 V flat cells (NiMH) / E-block
Diode test / resistance Test voltage max. 3.2 V
200 Ω ± (1.0% rdg + 5 digits) 2,000 Ω ± (0.8% rdg + 5 digits) 20 kΩ 200 kΩ 2,000 kΩ ± (1.2% rdg + 5 digits) Input sensitivity 1 MΩ (V DC) / 500 kΩ (V AC) Polarity Sign for negative polarity LCD (3 1/2 segments, 1,999 digits)
Fuse F 250 mA / 300 V, F 10 A / 300 V, (Ø 5 x 20 mm) Protection class II, double insulation Overvoltage CAT III - 300 V Pollution degree 2 Degree of protection IP 20 Max. rel. humidity < 75% rH non-condensing Operating temperature 0°C…40°C Storage temperature -10°C…50°C Power supply 1 x 9 V battery (NEDA 1604, IEC 6F22) Dimensions 77 x 139 x 28 mm Weight (incl. battery) 204 g
Test standards EN61010-1, EN61010-2-030, EN61010-2-033, EN61326-1, EN61326-2-2
Subject to technical alterations 12.15

Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.
This device complies with all necessary standards for the free movement of goods within the EU.
This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at: www.laserliner.com/info