Read the operating instructions and the enclosed brochure „Guarantee and additional notices“ completely. Follow the instructions they contain. Safely keep these documents for future reference. !

Compact laser distance meter for measuring length, area and volume

DISPLAY:

Laserliner LaserRange-Master X2 — Compact laser distance meter for measuring length, area and volume diagram (page 1)
Fig. 2 · Compact laser distance meter for measuring length, a…

Battery charge level Reference - rear, front / laser active Intermediate values / min, max values / angle at Pythagoras 1 in 2nd line Continuous measurement indicator Measured values / measurement results Units: m / _‘ _“ / inch / ft Length measurement display Addition / subtraction display Pythagoras 1, 2, 3 Area / area addition / volume

a

h

b

g

d

f

f g h i

e

KEYPAD:

Laserliner LaserRange-Master X2 — e diagram (page 1)
Fig. 3 · e
1. 2. 3. 4. 5.

Device on / laser active / measure / continuous measurement Pythagoras 1, 2, 3 Addition / subtraction of lengths delete last measurement values / device off Reference - rear, front / change unit of measure: m / _‘ _“ / inch / ft Area / area addition / volume / length

Laserliner LaserRange-Master X2 — e diagram (page 1)
Fig. 4 · e

Class 2 laser < 1 mW · 650 nm EN 60825-1:2007-10

Do not look directly into the beam. Lasers must be kept out of reach of children. Never intentionally aim the device at people. !

a b · d · e

Page 2 of the Laserliner LaserRange-Master X2 user manual — LaserRange-Master X2
Page 2 · click to enlarge
Page 2

LaserRange-Master X2

Switch on, measure and switch off: device on laser on measure device off

Laserliner LaserRange-Master X2 — LaserRange-Master X2 diagram (page 2)
Fig. 5 · LaserRange-Master X2
Change unit of measurePress and hold button: m / _‘ _“ / inch / ft
Change measurement point (reference)rear front
Laserliner LaserRange-Master X2 — LaserRange-Master X2 diagram (page 2)
Fig. 6 · LaserRange-Master X2
Change measurement functionarea area addition volume length

1x 2x 3x 4x

Length measurementdevice on laser on measure
Laserliner LaserRange-Master X2 — LaserRange-Master X2 diagram (page 2)
Fig. 7 · LaserRange-Master X2
Area measurementdevice on area 1. measure2. measurement ment
Laserliner LaserRange-Master X2 — LaserRange-Master X2 diagram (page 2)
Fig. 8 · LaserRange-Master X2
Page 3 of the Laserliner LaserRange-Master X2 user manual — LaserRange-Master X2
Page 3 · click to enlarge
Page 3
Area additiondevice on
1. measurement 2. measurement = area 1 3. measurement = area 1 + area 2
Laserliner LaserRange-Master X2 — LaserRange-Master X2 diagram (page 3)
Fig. 9 · LaserRange-Master X2

Addition of further areas: Laser active / ... measurement = area 1 + area 2 + area 3 + ...

Laserliner LaserRange-Master X2 — LaserRange-Master X2 diagram (page 3)
Fig. 10 · LaserRange-Master X2

Linked wall areas are added here. When adding areas, only the length needs to be measured as from the 3rd measurement. The value from the 1st measurement is always used as the height. !

Volume measurementdevice on volume 1. 2. 3. measurement
Laserliner LaserRange-Master X2 — LaserRange-Master X2 diagram (page 3)
Fig. 11 · LaserRange-Master X2

Addition and subtraction of lengths: device on laser on 1. length +/- etc.

Laserliner LaserRange-Master X2 — LaserRange-Master X2 diagram (page 3)
Fig. 12 · LaserRange-Master X2

area addition

Page 4 of the Laserliner LaserRange-Master X2 user manual — Pythagoras functions 1, 2, 3:
Page 4 · click to enlarge
Page 4

LaserRange-Master X2

Pythagoras functions 1, 2, 3:

Laserliner LaserRange-Master X2 — Pythagoras functions 1, 2, 3: diagram (page 4)
Fig. 13 · Pythagoras functions 1, 2, 3:
Pythagoras function 1device on Pythagoras 1 1. 2. measurement
Laserliner LaserRange-Master X2 — Pythagoras functions 1, 2, 3: diagram (page 4)
Fig. 14 · Pythagoras functions 1, 2, 3:
Pythagoras function 2device on Pythagoras 2 1. 2. 3. measurement
Laserliner LaserRange-Master X2 — Pythagoras functions 1, 2, 3: diagram (page 4)
Fig. 15 · Pythagoras functions 1, 2, 3:
Pythagoras function 3device on Pythagoras 3 1. 2. 3. measurement
Laserliner LaserRange-Master X2 — Pythagoras functions 1, 2, 3: diagram (page 4)
Fig. 16 · Pythagoras functions 1, 2, 3:
resultheight
Page 5 of the Laserliner LaserRange-Master X2 user manual — Pythagoras functions 1, 2, 3:
Page 5 · click to enlarge
Page 5
Continuous measurement / min/max valuesdevice on activate start stop

A signal sounds at 1 second interval during the measurement. The LC display shows the max value, the min value and the current value. The max value is required to determine diagonals while the min value is used to determine verticals and horizontals. !

Switch signal tone on/offdevice on tone on tone off

2 sec 2 sec

No objects may get into the laser‘s line of measurement. – The device compensates the measurement for different room

temperatures. Therefore allow the device a brief adaptation period when changing locations with large temperature differences. – The device is only conditionally useable in outdoor areas and

cannot be used in strong sunlight. – The measurement results of outdoor measurements may be

influenced or falsified by rain, fog and snow. – Carpeting, upholstery or curtains will not reflect the laser optimally.

Measure to flat surfaces. – Measurements made through glass (window panes) can falsify

measurement results. – An energy-saving function switches the device off automatically. – The batteries must be replaced when the battery symbol (a) starts

to flash.

2 sec

Page 6 of the Laserliner LaserRange-Master X2 user manual — Error codes:
Page 6 · click to enlarge
Page 6

LaserRange-Master X2

Technical Data (Subject to technical changes without notice)

Inside measurement range 0,5 m - 25 m

Precision (typical) ± 3 mm / 10 m*

Laser class 2 < 1mW

Laser wavelength 650 nm

Power supply 2 x AAA 1.5 Volt batteries

Dimensions 110 x 43 x 28 mm

Weight (incl. batteries) 110 g

Automatic switch-off 30 sec LCD lighting / 45 sec laser / 3 min device

Operating temperature 0°C – 40°C

Storage temperature -20°C – 70°C

Article number 080.944A

* measuring distance up to 10 m with strongly reflective target surface and at room temperature. The measurement deviation may increase by +/-0.2 mm/m for greater distances and under unfavourable measuring conditions such as strong sunlight or weakly reflective target surfaces.

Error codes:

301. 302:

Target is outside measuring range. Target is too dark or too much ambient light. Use a reflecting material as target for the measurement. Measured value cannot be shown by LC display. Set measured values to zero with button (4.). Pythagoras parameter error Replace the battery. Temperature is too low: < 0 °C Temperature is too high: > 40 °C Too much ambient light.

303:

304. 305: 306: 307: 308:

EU directives and disposal This device complies with all necessary standards for the free movement of goods within the EU. This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment. Further safety and supplementary notices at: www.laserliner.com/info

Ask about the Laserliner LaserRange-Master X2

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Laserliner LaserRange-Master X2

Be the first to ask — other owners or our team will answer.

Original document

Laserliner LaserRange-Master X2 manual PDF

72 pages·1.3 MB·Measuring instruments·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…