Read the operating instructions and the enclosed brochure “Guarantee and additional notices“ completely. Follow the instructions they contain. Safely keep these documents for future reference. !
Hazardous electrical voltage warning: Unprotected live components inside the device housing may pose a risk of electric shock.


1 Receptacle for receiver RECV 2 ON / OFF switch (side) 3 Cover 4 Status LED 5 Opening for adapter 6 TV-coax adapter 7 Battery compartment 8 RJ 45 adapter 9 Cable terminals 10 RJ 11 adapter 11 Test prod 12 Status LED 13 Receiver signal volume control (side) 14 Test mode button 15 Speaker 16 Battery compartment

Isolate the device from all measuring circuits before opening the battery compartment cover. It is recommended that you replace the batteries in the sender: When the status indicator light is weak. The batteries in the receiver should be replaced: If the signal volume becomes lower despite the fact that the position of the device or the volume control (13) has not changed. Do not switch on the device with the cover open.

4 x LR44 1,5 V button cells 2 x 1,5 V type AAA
In order to preserve the batteries, the meter switches off automatically if it is left idle for 30 minutes.
Ensure correct polarity!




a b

Make the measuring circuit zero-potential. Shields in the cable and in the surrounding area (metal coverings, metal supports, etc.) reduce the range of the receiver. !
Connect cable terminals (9) to the required cable. Then use the receiver to search for the line, with the test mode button (14) held down.

To achieve the maximum measuring depth, set the receiver signal volume as high as it will go (13).
To trace a single cable, connect the red terminal to the cable to be traced and the black terminal to earth (earthing conductor or shielding).
The signal is weak when connected to two signal lines within a cable. !

Connect the RJ 45 adapter (8) to a network socket. Then use the receiver to search for the line, with the test mode button (14) held down.

Connect the TV-coax adapter (6) to a TV socket. Then use the receiver to search for the line, with the test mode button (14) held down.
To avoid interference, disconnect the building TV service. TV sockets in particular may contain filters that have a negative effect on measurements. In this case, remove the TV socket and perform the measurement directly at the cable. !
Connect the RJ 11 adapter (10) to a telephone socket. Then use the receiver to search for the line, with the test mode button (14) held down.
Transmitter TX / Receiver RECV
Signal Multi-frequency pulse Max. input voltage 20 V DC Max. rel. humidity < 85% rH non-condensing Operating temperature -10°C…40°C Storage temperature -10°C…50°C
Max. output current 10 mA Max. signal voltage 8 Vss (peak-to-peak) Max. testing length 100 m Power supply 2 x 1,5 V type AAA Dimensions 80 x 152 x 46 mm Weight (incl. batteries) 185 g
Max. output current 30 mA SCAN mode measuring range 0 - 5 cm measuring depth Power supply 4 x LR44 1,5 V button cells Dimensions 26 x 148 x 17 mm Weight (incl. batteries) 45 g
Subject to technical alterations 01.16
Technical data · Transmitter TX · Receiver RECV

Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.
This device complies with all necessary standards for the free movement of goods within the EU.
This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at: www.laserliner.com/info