EN
Laserliner logo
Official user manual

Laserliner AC-Check

92 pages·9.9 MB·Miscellaneous·PDF·ENJA
Laserliner AC-Check
Table of Contents 3 sections Symbols · AC-Check · Inserting batteries ShowHide
Page 1 of the Laserliner AC-Check user manual — Symbols
Page 1 · click to enlarge
Page 1

Read the operating instructions and the enclosed brochure „Guarantee and additional notices“ completely. Follow the instructions they contain. Safely keep these documents for future reference. !

Function / Application Non-contact voltage tester with adjustable sensitivity for localising electrical voltage in cables, sockets, lampholders and fuses. Visual and acoustic signals indicate whether a voltage is present.

  • Safety instructions
  • In overvoltage category III (CAT III), the voltage between the test device and earth must not exceed 1000 V.
  • Do not use the device in environments in which there are conductive particles or where the occurrence of moisture (in the form of condensation, for example) can create transient conductivity.
  • Do not expose the device to mechanical stress, extreme temperatures or significant vibration.
  • Do not expose the device to moisture or liquids. When using the device outdoors, make sure that the weather conditions are appropriate and/or that suitable protection measures are taken.
  • Please ensure compliance with the safety regulations set out by local and national authorities with regard to the correct and proper use of the device.

Symbols

Protection class II: The test device has reinforced or double insulation.

Overvoltage category III: Equipment in fixed installations and for applications where specific requirements with regard to the reliability and availability of equipment have to be met, e.g. circuit-breakers in fixed installations and devices used in industrial applications which are permanently connected to the fixed installation.

Page 2 of the Laserliner AC-Check user manual — Inserting batteries
Page 2 · click to enlarge
Page 2

AC-Check

Laserliner AC-Check — AC-Check diagram (page 2)
Fig. 1 · AC-Check

1 2 3 4 5 6

Detector tip ON / OFF Adjustment of sensitivity

Pocket clip Battery lamp ON / OFF

Battery lamp Battery compart- ment on the rear of the device

Inserting batteries

Open the battery compartment and insert batteries according to the symbols. Be sure to pay attention to polarity.

Laserliner AC-Check — Inserting batteries diagram (page 2)
Fig. 2 · Inserting batteries
Laserliner AC-Check — Inserting batteries diagram (page 2)
Fig. 3 · Inserting batteries

Before using the device, you should always test it on a main circuit you know to be operational within the specified voltage range. To avoid inaccurate measurements, check the device batteries prior to use by switching on the built-in battery lamp (see 5). !

Page 3 of the Laserliner AC-Check user manual — AC-Check
Page 3 · click to enlarge
Page 3
Laserliner AC-Check — AC-Check diagram (page 3)
Fig. 4 · AC-Check

Position the detector tip in the area to be tested (e.g. cable, socket. etc.).

If voltage is present, the detector tip lights up and a signal sounds.

The lines under current can be determined by adjusting the sensitivity.

Laserliner AC-Check — AC-Check diagram (page 3)
Fig. 5 · AC-Check

For safety, check all three phase conductors (L1, L2, L3) for the presence of voltage! !

If the acoustic signal is weak or the battery lamp is not as bright as it should be, replace the batteries. !

By turning the wheel (2), the sensitivity of the device (5 ... 1000 VAC) can be adjusted. This enables voltage fields to be located at significant distance by moving the device over the area to be tested.

If voltage is present, the detector tip lights up and a signal sounds.

Laserliner AC-Check — AC-Check diagram (page 3)
Fig. 6 · AC-Check

Please be aware that even if a visual signal is not displayed, voltage may still be present. Differences in the design of the connection socket or the nature of the insulation (thickness and type) can affect functionality. Voltage cannot be detected behind panels and metal covers. !

Page 4 of the Laserliner AC-Check user manual — AC-Check
Page 4 · click to enlarge
Page 4

AC-Check

Battery lamp To switch on the battery lamp, press and hold down button 4. The light switches itself off automatically as soon as the button is released.

Technical data IndicatorLED, acoustic signal Voltage range5 V/AC ... 1000 V/AC Frequency50 ... 400 Hz Overvoltage categoryCAT III - 1000V Power supply2 x 1.5V alkaline batteries (type AAA) Operating temperature0 °C … 40 °C Dimensions (W x H x D)154 x 32 x 28 mm Weight (incl. batteries)50 g

Subject to technical alterations. 01.14

EU directives and disposal This device complies with all necessary standards for the free movement of goods within the EU. This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment. Further safety and supplementary notices at: www.laserliner.com/info

Ask about the Laserliner AC-Check

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Laserliner AC-Check

Be the first to ask — other owners or our team will answer.

Original document

Laserliner AC-Check manual PDF

92 pages·9.9 MB·Miscellaneous·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…