Serial console port clock output (T4) WAN port (xDSL)



Status LED · WAN port (fiber) LAN ports

The ADTRAN Remote Device has various status LEDs: Note: the Status LED (STAT) is controlled by the configuration server after being switched on – see Table 3.

If the RD does not run into an error when starting, control of the STAT LED is taken over by the configuration server and the following states are signaled:


The stored basic configuration of a remote device is customer- and service independent (see chapter 4.5). This means that it can only “register” on the BNG platform.


Installation instructions when using the 230 V AC power supply:
For the 230 V model, the following connection sequence must be adhered to in order to ensure correct grounding/personal protection: connection sequence at body 1) Connection of the 230V cold supply cable of the power packet to a 230V voltage source (Schuko socket) correctly installed according to DIN / VDE 2) Connection and 48V cable coming from the power adapter to remote device 3
Removal order 1) Removing the WAN connection 2 Remove the LAN connection(s 3) Repair of 48 V cable coming from power supply unit from remote device 3 Removement of 230V cold-setting cable from power source to 230 V voltage (Schuko socket)
As long as Cu cable connections are connected to the device, the power supply cable must always be left switched on.
For the 48V model, the following connection order must be followed to ensure correct grounding of personal protection; the supplied earth cable always connected: connection sequence at body 1) Connection of the “earth” conductor on the supplied 48V cable at the remote device’s ground screw 2 connection of provided 48V wires to the remote devices and a properly grounded 48V voltage source 3 connection LAN link(s)
Construction order 1) Removal of WAN connection 2 . Remove the LAN link(s 3) Replacement of 48V cable from remote device and 48V voltage supply 4
As long as Cu cable connections are connected to the device, the earthing cable must always be left switched on.
The NV4660 can be installed both as a freestanding tabletop device and built-in into a rack. For mounting as a tabletop device, self-adhesive rubber feet are supplied which can be glued to the underside of the device.
A set of mounting angles is required for assembly in the rack (kit, contains 19 inches once and one for ETSI/21 or ETSI-21). 23 duty.


The connection of the interfaces of NV4660 for the product “Deutschland LAN Connect IP” is as follows:

The “EVPL light” measure realizes the following products:
Ethernet Connect 2.0 Wholesale Ethernet VPN 2.0 (WEV 2.0) CFV Ethernet 2.0
The basic configuration is the only configuration when RD starts. Only service-independent things, such as e.g. B. the configuration for VLAN 7 (PPP to BNG) and VLAN 3 (management and IP address allocation via DHCP), permanently stored.