. . . c o n n e c t i n g y o u r b u s i n e s s


© 2011 LANCOM Systems GmbH, Wuerselen (Germany). All rights reserved.
While the information in this manual has been compiled with great care, it may not be deemed an assurance of product characteristics. LANCOM Systems shall be liable only to the degree specified in the terms of sale and delivery.
The reproduction and distribution of the documentation and software supplied with this product and the use of its contents is subject to written authorization from LANCOM Systems. We reserve the right to make any alterations that arise as the result of technical development.
Windows®, Windows Vista™, Windows 7® and Microsoft® are registered trademarks of Microsoft, Corp.
The LANCOM Systems logo, LCOS and the name LANCOM are registered trademarks of LANCOM Systems GmbH. All other names or descriptions used may be trademarks or registered trademarks of their owners.
Subject to change without notice. No liability for technical errors or omissions.
Products from LANCOM Systems include software developed by the OpenSSL Project for use in the OpenSSL Toolkit (http:/ /www.openssl.org/).
Products from LANCOM Systems include cryptographic software written by Eric Young (eay@cryptsoft.com).
Products from LANCOM Systems include software developed by the NetBSD Foundation, Inc. and its contributors.
Products from LANCOM Systems contain the LZMA SDK developed by Igor Pavlov.
Adenauerstr. 20/B2

LANCOM Switches are ideally suited to small, medium-sized and performance networks in business environments.
The LANCOM GS-1224 switch features 24 Gigabit-Ethernet and four combo ports (TP/SFP), it integrates perfectly into LANCOM's Advanced Routing und Forwarding and it supports up to 24 active VLANs. It uses bandwidth control to prioritize the data traffic according to predefined criteria (e.g. voice data or certain ports).
The LANCOM Switch can be managed with the clearly structured Webconfig and is supported by the LANCOM Management Tools (LANconfig and LANmonitor).
Furthermore the LANCOM GS-1224P switch supports Power-over-Ethernet for connected network devices. The overall power output of 185 Watts from the PoE supply can be flexibly divided between the ports.
This documentation is intended for LANCOM Switch users. The following models are available:
The LANCOM GS-1224 without PoE support. The LANCOM GS-1224P with PoE support.
Passages applying only to certain models are identified either in the text itself or by a comment in the margin.
Otherwise the documentation refers to all models collectively as the LANCOM Switch series.
This documentation was created by …
... several members of our staff from a variety of departments in order to ensure you the best possible support when using your LANCOM product.
Should you find any errors, or if you would like to suggest improvements, ple- ase do not hesitate to send an e-mail directly to: info@lancom.eu I
Our online services www.lancom.eu are available to you around the clock if you have any questions on the content in this manual, or if you require any further support. The area 'Support' will help you with
Preface · Model variants · Model restrictions

many answers to frequently asked questions (FAQs). Furthermore, the knowledgebase offers you a large reserve of information. The latest drivers, firmware, utilities and documentation are constantly available for download. In addition, LANCOM Support is available. For telephone numbers and contact addresses for LANCOM Support, please refer to the enc- losed leaflet or the LANCOM Systems Web site.
Very important instructions. Failure to observe these may result in damage. C
Important instruction that should be observed. I
Additional information that may be helpful but is not essential.
Preface


The LANCOM GS-1224 is a websmart layer-2 switch with 20 Gigabit ports (for twisted pair cable – TP) and four Gigabit dual media ports with TP/SFP, which meets the IEEE 802.3 Gigabit, Fast Ethernet and Ethernet specifications.
The LANCOM Switches can be configured through WEBconfig.
The overall network management is enhanced and the network efficiency is also improved to accommodate high bandwidths. In addition, the switch fea- tures comprehensive and useful function such as QoS (Quality of Service), Spanning Tree, VLAN, Port Trunking, Bandwidth Control, Port Security, SNMP and IGMP Snooping capability via the intelligent software. It is suitable for both metro-LAN and office application.
The LANCOM GS-1224P switch also complies with IEEE 802.3af, its advanced auto-sensing algorithm enables providing power devices (PD) discovery, clas- sification, current limit, and other necessary functions. It also supports high safety with short circuit protection and power-out auto-detection to PD.
The 10/100/1000 Mbps TP-Ports are standard Ethernet ports that meets all IEEE 802.3/u/x/z (Gigabit and Fast Ethernet) specifications.
The 1000 Mbps SFP Fiber transceiver are Gigabit Ethernet ports that fully complies with all IEEE 802.3z and 1000Base-SX/LX standards. The Single Fiber WDM (BiDi) transceiver is designed with an optic Wavelength Division Multiplexing (WDM) technology that transports bi-directional full duplex sig- nal over a single fiber simultaneously.
QoS:
Support Quality of Service by the IEEE 802.1P standard. There are two priority queue and packet transmission schedule using Weighted Round Robin (WRR). User-defined weight classification of packet priority can be based on either VLAN tag on packets or user-defined port priority.
Spanning Tree:
Support IEEE 802.1D, IEEE 802.1w (RSTP: Rapid Spanning Tree Protocol) standards.
Support Port-based VLAN and IEEE 802.1q Tag VLAN. Support 24 active VLANs and VLAN ID 1~4094.

Port Trunking:
Support static port trunking and port trunking with IEEE 802.3ad LACP.
Bandwidth Control:
Support ingress and egress per port bandwidth control.
Power saving:
The switch can detect inactive links and deactivate the power supply for the corresponding ports
SNMP agent. In the device, SNMP agent is a client software which is ope- rating over SNMP protocol used to receive the command from SNMP manager (server site) and echo the corresponded data, i.e. MIB object. Besides, SNMP agent will actively issue TRAP information when happe- ned.
The device supports MIB II (RFC1213), Bridge MIB (RFC1493), Interface Group MIB (RFC2863).
IGMP Snooping:
Support IGMP version 2 (RFC 2236): The function IGMP snooping is used to establish the multicast groups to forward the multicast packet to the member ports, and, in nature, avoid wasting the bandwidth while IP mul- ticast packets are running over the network.


This chapter will assist you to quickly install hardware and software. First, check the package contents and system requirements. The device can be installed and configured quickly and easily if all prerequisites are fulfilled.
Before beginning with the installation, please check that nothing is missing from your package. Along with the LANCOM Switch the box should contain the following accessories:
Should anything be missing, please take up immediate contact to your dealer or to the address on the delivery note supplied with your device.
Computers that connect to a LANCOM must meet the following minimum requirements:
Operating system with TCP/IP support, such as Windows, Linux, BSD Unix,
Apple Mac OS, OS/2. Access to the LAN via the TCP/IP protocol. I
The LANtools also require a Windows operating system. A web brow- ser under any operating system provides access to WEBconfig.
Meanings of the LEDs
The following section describes the meaning of the LEDs.

Please be aware that LANmonitor shows far more information about the status of the LANCOM Switch than the LEDs '→ Monitoring the LANCOM switch with LANmonitor'.
Located on the front of the device are connectors for different cabletypes, light-emitting diodes (LEDs) that provide information on device status, and also a button.

POWER LED Constant green when power is supplied to the device. LINK / ACT LED
Constant green when the network connection is established to the con-
Port 1 to 24
nected device. Blinks during data transfer. Off if no network connection can be established to the connected device. 10/100/1000
Constant green when the 1000 Mbps mode is active. Constant orange when the 100 Mbps mode is active. Off when the 10 Mbps is active. SFP (LINK/ACT)
Constant green when the network connection is established to the con-
nected device. Blinks during data transfer. Off if no network connection can be established to the connected device. Reset Button to reset the system. If you press the button longer than three seconds, all settings will be reset to default (factory setting). D
The device starts after the reset in an unconfigured mode and all set- tings will get lost. Therefore you should save the actual configuration before you reset the device!
TP connectors Connectors for twisted-pair cables. SFP connec-
Connectors for small form-factor pluggable (SFP) modules.
Mbps LED · tors

The following connectors are located on the rear of the device.
Connector for the power supply cable.
Installating the LANCOM Switch involves the following steps:
Mounting – The device is designed for mounting in an available 19” unit
in a server cabinet. If necessary fix the rubber pads to the underside of the device to prevent any scratching to other equipment. C
Ensure that the device has sufficient ventilation to prevent damage from excessive heat build-up.
LAN connection – Connect the network devices to the ports of the LAN-
COM Switch by means of a suitable twisted-pair cable (TP cable). The con- nectors automatically detect the avalable data transfer speeds and the pin assignment (autosensing). I
Use only standard TP cables of category CAT 5e or better with a maxi- mum length of 100 m to ensure the best possible transfer of data. Cross-over cables can be used thanks to the auto-sensing function. I
If optical connections are to be used, additional modules can be purchased as accessories.
Supply power and switch on – Supply power to the device by means of
the IEC power cable.
Ready for operation? – After a brief self-test, the power LED lights up
continuously. Green LAN-LINK LEDs show which LAN connectors are being used for a connection.

The following section describes the installation of the Windows-compatible system software LANtools, as supplied. I
You may skip this section if you use your LANCOM Switch exclusively with computers running operating systems other than Windows.
Place the supplied data medium (CD/DVD) into your drive. The setup program will start automatically. I
If the setup does not start automatically, run AUTORUN.EXE in the root directory of the data medium.
In Setup, select Install software. The following selection menus will appear on screen:


LANconfig is the Windows configuration program for all LANCOM
devices. LANconfig searches for all LANCOM devices in your network. You can use this to start the Web-based configuration of a LANCOM Switch.
With LANmonitor you can use a Windows computer to monitor all of
your LANCOM devices. This program displays all important status infor- mation for a LANCOM Switch, such as link status or port PoE state.
With Documentation you copy the documentation files onto your PC.
Select the appropriate software options and confirm your choice with Next. The software is installed automatically.

The configuration is done over a graphical user interfacevia a browser (WEBconfig). Instructions for configuring the device with WEBconfig are avai- lable in the chapter "Web-based configuration".
There are two ways of starting the configuration by browser:
If you know the device's IP address, simply enter this into the address line
in the browser. The password for accessing the device is "admin".

If you do not have the device's IP number, LANconfig can be used to
search for it. To start LANconfig click on Start Programs LANCOM LANconfig.


LANconfig automatically searches for all available devices in your net- work. Any available LANCOM devices will be displayed in the list, inclu- ding the LANCOM Switch. Double-click on this entry to start the browser automatically with the correct IP address.
What is the IP address of my LANCOM Switch?
The current IP address of the LANCOM Switch after being switched on depends on the network constellation.
Networks with DHCP server – In its factory settings, the LANCOM Switch is set for auto DHCP mode, meaning that it searches for a DHCP server to assign it an IP address, subnet mask and gateway address. The assigned IP address can only be determined by using the appropriate tools or via the DHCP server. If the DHCP server is a LANCOM device, the IP address of the LAN- COM Switch can be read out from the DHCP table. If this is the case, the LANCOM Switch can be accessed from any network computer that receives its IP address from the same subnetwork.
Network without a DHCP server – If no DHCP server is present in the network, the LANCOM Switch waits about 5 minutes and then automatically adopts the address "172.23.56.250".
If this is the case, the LANCOM Switch can be accessed from any network computer with its IP address set to the address range "172.23.56.x".
With this function you can back up or reload you current configuration for safety reasons. This backup can be uploaded into a new or defective device.

The current state of the device and all ports can be monitored using the LEDs on the front panel. With LANmonitor the devices can be observed from any workstation without being able to see the LEDs. Besides the status informa- tion provided by the LEDs the LANmonitor provides further important infor- mation on the ports.
LANmonitor displays the current status of all of the device's Ethernet ports. This includes monitoring of the state as configured by the admin (config state) and the actual state (link state) of the port. Each port is displayed with two colored symbols in LANmonitor:

The left icon shows the config state:
Gray: The port is deactivated in the configuration Yellow: The port is activated in the configuration The right-hand icon shows the link state:
Gray: No active network device is connected to the port Green: A network device is connected to the port and active

This chapter instructs you how to configure and manage the switch through the web user interface (WEBconfig). With this facility, you can easily access and monitor through any one port of the switch all the status of the switch.
The default values of the managed switch are listed in the table below:
GS-1224P
IP Adress 172.23.56.250
Subnet Mask 255.255.255.0
Default Gateway 172.23.56.254
Web Smart Switch supports a simplified user management function which allows only one administrator to configure the switch at one time. Fill in the IP address in the address row in a browser to start WEBconfig. The default password is “admin”.
After login, System Information will be displayed as the following screenshot illustrates:
Password admin


The Information of Page Layout
The top part of the information page shows the front panel of the switch. Lin- ked ports are displayed in green color, and ports without link in black.
The ports for the optional SFP modules show a demonstration of the module, if it is installed. Ports without installed SFP modules show covered plates.
On the left side, the main menu tree for web management is listed on the page. According to the function name in bold, all functions can be divided into three parts: Configuration, Monitoring and Maintenance. The functions of each folder are described in its corresponded section respectively. When cli- cking it, the function is performed.

Configuration includes the following functions: System Configuration, Ports Configuration, VLAN Mode Configuration, VLAN Group Configuration, Aggre- gation, LACP, RSTP, 802.1X, IGMP Snooping, Mirror, QoS, Filter, Rate Limit, Storm Control and SNMP.
In the system configuration you can define the basic parameter for the confi- guration and the operation of the device. The switch supports manual IP address setting and further address information via DHCP or the manual set- ting of a fixed IP address.

System Description:
The simple description of this switch.
Firmware Version:
The firmware version of this switch.

Hardware Version:
The hardware version of this switch.
MAC Address:
It is the Ethernet MAC address of the management agent in this switch.
Serial Number:
The serial number assigned by the manufacturer.
Active IP Address:
Shows the active IP address of this switch.
Active Subnet Mask:
Shows the active subnet mask of this switch.
Active Gateway:
Shows the active gateway of this switch.
DHCP Server:
Shows the IP address of the DHCP server.
Lease Time Left:
Show the lease time left of DHCP client.
Device Name:
Set a special name for this switch. Up to 16 characters are allowed in this parameter. Any alphanumeric character and zero are acceptable.
DHCP Enabled:
You can enable the automatic delivery of an IP address and activate further adress information via DHCP.
Fallback IP Address:
Fill in an IP address, which is used by the device, if DHCP is disabled or the DHCP server is not accessible.
Fallback Subnet Mask:
Fill in a subnet mask, which is used by the device, if DHCP is disabled or the DHCP server is not accessible.

Fallback Gateway:
Fill in a gateway, which is used by the device, if DHCP is disabled or the DHCP server is not accessible.
Management VLAN:
Shows the ID of the management VLAN.
Password:
Set a password for this switch. Up to 16 characters are allowed in this parameter. Any alphanumeric character is acceptable.
Inactivity Timeout(secs):
Set the auto-logout timer. The valid value is 0-60 in the unit of minute and a decimal point is not allowed. The value 0 means auto-logout timer is disabled.

Here you can configure the individual ports.


Enable Jumbo Frames:
Jumbo frames are not standardized and oversized frames. This function support jumbo frames of up to 9600 bytes.
Power Saving Mode:
This function supports Power Saving, to deactivate automatically the power supply for the ports with inactive links. Select: Enable/ Disable.
Link:
Shows link status of this port.

Mode:
Set the speed and duplex of the port. If the media is 1Gbps fiber glass, there are three modes to choose: Auto Speed, 1000 Full and Disable. If the media is TP, the Speed/Duplex is comprised of the combination of speed mode, 10/100/1000Mbps and duplex mode, full duplex and half duplex. The following table summarizes the functions the media supports:
Medium NWay Speed Duplex
Twisted Pair ON/OFF 10/100/1000M Full for all, Half for 10/100
1 Gbit-Faser ON/OFF 1000M Full
Flow Control:
You can tick the check box to enable flow control. If flow control is set to Enable, both parties can send a PAUSE frame to the transmitting device(s) if the receiving port is too busy to handle. When it is set to Disable, there will be no flow control in the port. It drops the packet if there is too much traffic.
Flow Control status:
To display the Flow control status.
Displays the information about the PoE status.

LANCOM GS-1224P only · PoE Status

Vmain: The voltage supplied by the switch. Imain: The sum of the current that every port supplies. Pconsume: The sum of the power that every port supplies. Power Limit: The maximal power that the switch can supply (Read
Only). Temperature: The PoE temperature. Port No: Port number. Port On: Shows whether the port is supplying the power to the powe-
red device or not. AC Disconnect Port Off: Port is turned off due to the AC Disconnect
function. DC Disconnect Port Off: Port is turned off due to the DC Disconnect
due to the power required by the powered device that is linked to the port on the switch exceeding the Class setting of the powered device. Short Circuit Port Off: The switch will stop supplying the power to the
port if it detects that the powered device linked to the port is short cir- cuit. Over Temp. Protection: The PoE will be disabled when the temperature
on chip will rise to 150°C. Power Management Port Off: Due to total power required by all
powered devices linked to the switch excesses the power limit, so the switch stops supplying the power to this port after referring to the information of the priority.
In the PoE Port Management the PoE settings can be configured.
The switch complies with IEEE 802.3af protocol and is capable of detec- ting automatically whether the device linked to the port on the switch is a PoE capable device or not. The switch also manages the power supple- ment based on the Class of the powered device, and it will stop supplying
PoE Configuration

the power once the power required by the powered device exceeds the Class, Short Circuit or over temperature occurs.

the port is ready to link and supply the power to the powered device at any time. The latter means the port is currently supplying power. State: “Enable” allows power supply while a device is linked to the
port; “Disable” means the port does not support PoE functions. Priority: Choices are "Normal", "Low" and "High". The former being
the default choice. In case the power required by all linked devices exceeds the maximum available power, the switch will cut power to the devices with the lowest priority. If ports have the same priority, the switch will stop the power supply to the port with the highest port id. Power(W): The power consumed by the port. Current(mA): The current supplied by the port. Class: The class of the powered device linked to the port of the switch.

The switch supports Tag-based VLAN (802.1q) and Port-based VLAN. Its VLAN mode supports 24 active VLANs and and the available VLAN ID range is from 1~4094. VLAN configuration is used to divide a LAN into smaller ones. With proper configuration you can not only gain improved security and incre- ased performance but greatly reduced VLAN management.
VLAN Mode Setting
The VLAN Mode Selection function includes four modes: Port-based, Tag- based and Metro mode.

VLAN Mode:
Port-based:
A port-based VLAN defines its members by port. Any packet coming in or going out from any port of a port-based VLAN will be accepted. No filtering criterion applies in a port-based VLAN, the only criterion is the physical connection to a member port. For example in a port- based VLAN with the member ports 1, 2, 3 and 4, the ports 1, 2, 3 and 4 can communicate with each other, but port 5 can not commu- nicate with them. Each port-based VLAN is identified with an ID (1 to 4094) and you can capture further information about the VLAN in a description. This switch supports up to maximal 24 port-based VLANs.
As soon as the VLAN mode is set on “port-based”, the display auto- matically changes to the configuration of the port-based VLAN groups.


Tag-based:
A tag-based VLAN identifies its member by VLAN-ID. If there are any more rules in ingress or egress filtering lists, this rules determines if the packet will be forwarded or not. The switch supports standard of 802.1q.
Each tag-based VLAN you set up must get a VLAN name and VLAN ID. A valid VLAN ID is 1 up to 4094. You can create up to 24 Tag VLAN groups.
As soon as the VLAN mode is set on “tag-based”, the setting double- tag mode will be offered. If the double-tag mode is activated all packets (tagged or untagged) will get a VLAN tag. Packets which have already an “inner” tag will get in addition an “outer” tag. Internet ser- vice provider use this function for additionally tagging in their own network of customers VLAN tagged data streams.
If the double-tag mode is activated, you can select the ports on which the doubled VLAN tags should be used.


After confirmation of the tag-based VLAN mode, the display auto- matically changes to the configuration of the tag-based VLAN groups.

Metro Mode:
The Metro mode is a quick method to configure port-based VLANs. Metro mode can be activated for the ports 21, 22, 23 and 24. This option is usually used to get a comfortable uplink to the metro ether- net environment.


After confirmation of the Metro mode the display changes to the con- figuration of the port-based VLAN groups. At the same time for all ports without metro mode support a VLAN group is set up. This VLAN group contains the respective port and the ports with metro mode support. Ports can be deleted manually from certain groups if needed.

Shows the information of VLAN Groups, and allows administrators to maintain them by modifying and deleting each VLAN group.
The display differs depending on the current VLAN mode:
If you are in port-based VLAN or in metro mode, it will just show the ID
and the descriptions of the existing members. If you are in tag-based VLAN, it will show the ID and the descriptions of
the existing members. Additionally you can define further options for each port.
The switch can store the configuration of port-based VLAN and tag-based VLAN separately.

Add:
Adds a new port-based or tag-based VLAN.
Modify:
Click on Modify to edit the selected VLAN.
Delete:
Click on Delete to remove the selected VLAN.

ID of the VLAN group (1 to 4094). The packet forwarding is based on this ID.
Member:
Select the member ports of the VLAN group.
General functions · VLAN group configuration


In tag-based mode you can define further settings for each port. Please click the Port Config button in the list of tag-based VLAN group.
VLAN Port Configuration

Ingress Filtering enabled:
If the filter for incoming packets is activated, packets on this port are for- wared only, if the port is member of the corresponding VLAN group. Packets with other VLAN tags are discarded.
Packet Type:
All: Forwards all packets (tagged and untagged). Tagged Only: Forwards tagged packets only and discards untagged
packets. Role:
Defines the rules for outgoing packets.
are detected, the outer tag will be removed. This option is generally used if end devices are connected to the port. Trunk: Packets on this port are forwarded using the current tag. Hybrid: Similar to trnuk, packets on this port are forwarded using the
current tag. If the current tag matches the “Untagged VLAN ID”, the tag will be removed. Untagged VLAN ID:
Active only if the role is set to hybrid. This value (from 1 to 4094) defines the tag, which will be removed from outgoing packets.
PVID (Port VLAN ID):
This VLAN ID from 1 to 4094 is used to tag incoming packets for forwar- ding. Only VLAN IDs which are defined in the list of tag-based VLAN groups can be used as Port VLAN ID.


The Aggregation (Port Trunking) Configuration is used to configure the set- tings of Link Aggregation. You can bundle more than one port by same speed, full duplex and the same MAC to be a single logical port, thus the logical port aggregates the bandwidth of these ports. This means you can apply your cur- rent Ethernet equipments to build the bandwidth aggregation.


The Aggregation Configuration displays the current setup of Aggregation Trunking. With this function you can add a new trunking group or modify the members of an existing trunking group.
Normal:
Set up the ports that do not join any aggregation trunking group.
Group 1-8:
Groups the ports you choose together. Up to 12 ports can be selected for each group. I
The aggregation groups has to be set up one after each other. Group 2 will remain inactive until the ports for group 1 are selected and the settings are stored with Apply.
Smart Web Switch supports “Link Aggregation Control Protocol” (LACP). LACP is a standard network protocol IEEE 802.3ad which dynamically creates and manages trunk groups.
When you enable LACP link aggregation on a port, the port can automatically negotiate with the ports at the remote end of a link to establish trunk groups. LACP also allows port redundancy, that is, if an operational port fails, then one of the "standby" ports become operational without user intervention.

Protocol Enabled:
Just tick the check box to enable LACP protocol then press Apply.
Key Value:
It's a key for an aggregation. This must be an integer value between 1 and 255 or auto select by switch.

Rapid Spanning Tree protocol (RSTP) detects and resolves network loops, respectively in case of need (breakdown of a connection) to activate it again. The protocol allows a switch to communicate with other RSTP compliant swit- ches and to ensure, that only one path exists between two end points in your network.
System Priority:
System priority is used to determine the root switch, thus the root of the spanning tree. The switch with the highest priority (lowest numeric value) becomes the root switch. If all switches have the same priority, the switch with the lowest MAC address will become the root switch. Select a value from the drop-down list box. (The lower the numeric value you assign, the higher the priority for this system.)
Hello Time:
Hello Time is the time interval, in which the switch tells the following devices in the spanning tree, with a “hello packet”, that it is still active. If for example the LANCOM Switch is the root switch of the LAN, all other bridges will use the hello time assigned by this switch to communicate with each other. The allowed range is 1-10 second.
Max. Age:
If there are no “hello packets” for a certain time, a device in the spanning tree assumes a change in the structure. In this case all connections in the network need to be established again.
Maximum Age is the maximum time a switch can wait without receiving a “hello packet” before attempting to reconfigure. During this time of reconfiguration, all STP-capable devices in the network send only admi- nistration packets, but no reference data of the connected devices.
The valid value of Max. Age is 6 -40 seconds.
Forward Delay:
Forward delay time is the maximum time (in seconds) a switch waits before changing its state.

For example the time a brige port needs, to move from “Listening state” to “Learning state” or from “Learning state” to “Forwarding state”. The general rule is:
2 * (Forward Delay - 1) >= Max Age >= 2 * (Hello Time + 1).
Force Version:
For the STP algorithm you can select between two options in the drop- down list: RSTP or STP. Rapid Spanning Tree Protocol (RSTP) is an exten- sion of STP and reduces the needed time for the new organisation of a network after structure changed.
Enable or disable RSTP protocol on the ports that are selected. Decide if the Port should be an edge port and set path costs.
Protocol Enabled:
Just tick the check box beside the port x to enable RSTP protocol, then press Apply.
Edge:
An Edge Port is a port connected to a device that knows nothing about STP or RSTP. Usually, the connected device is an end station. Edge Ports will immediately transit to forwarding state and skip the listening and learning state because the edge ports cannot create bridging loops in the network. This will expedite the convergence. When the link on the edge port toggles, the STP topology keeps unchanged. Unlike the designate port or root port though, an edge port will transit to a normal spanning- tree port immediately if it receives a BPDU.
Just tick the check box beside the port x to enable edge function.
Path Cost:
Path cost is the cost of transmitting a frame on to a LAN through that port. It is assigned according to the speed of the bridge. The slower the media, the higher the cost. You can select auto or set the range from 1- 200000000.
RSTP Port Configuration


802.1x port-based network access control provides a method to restrict users to access network resources via authenticating user’s information. This rest- ricts users from gaining access to the network resources through a 802.1x- enabled port without authentication. If a user wishes to touch the network through a port under 802.1x control, he (she) must firstly input his (her) account name for authentication and waits for gaining authorization before sending or receiving any packets from a 802.1x-enabled port.
Before the devices or end stations can access the network resources through the ports under 802.1x control, the devices or end stations connected to a controlled port send the authentication request to the authenticator, the authenticator pass the request to the authentication server to authenticate and verify, and the server tell the authenticator if the request get the grant of authorization for the ports.
According to IEEE 802.1x, there are three components implemented. They are Authenticator, Supplicant and Authentication server.

Supplicant:
It is an entity being authenticated by an authenticator. It is used to com- municate with the Authenticator PAE (Port Access Entity) by exchanging the authentication message when the Authenticator PAE request to it.
Authenticator:
An entity facilitates the authentication of the supplicant entity. It controls the state of the port, authorized or unauthorized, according to the result of authentication message exchanged between it and a supplicant PAE. The authenticator may request the supplicant to re-authenticate itself at a configured time period. Once start re-authenticating the supplicant, the controlled port keeps in the authorized state until re-authentication fails.
A port acting as an authenticator is thought to be two logical ports, a con- trolled port and an uncontrolled port. A controlled port can only pass the packets when the authenticator PAE is authorized, and otherwise, an uncontrolled port will unconditionally pass the packets with PAE group MAC address, which has the value of 01-80-c2-00-00-03 and will not be forwarded by the MAC bridge, at any time.
Authentication server:
A device provides authentication service, through EAP, to an authentica- tor by using authentication credentials supplied by the supplicant to determine if the supplicant is authorized to access the network resource.
The overview of operation flow for the following figure is quite simple. When the Supplicant PAE issues a request to the Authenticator PAE, Authenticator and Supplicant exchange authentication messages. Then, the Authenticator passes the request to the RADIUS server to verify. Finally, the RADIUS server replies if the request is granted or denied.
While in the authentication process, the message packets, encapsulated by Extensible Authentication Protocol over LAN (EAPOL), are exchanged between an authenticator PAE and a supplicant PAE. The Authenticator exchanges the message to the authentication server by using EAP encapsulation. Before suc- cessfully authenticating, the supplicant can only reach the authenticator to perform authentication message exchange or access the network from the uncontrolled port.


In the following figure is the typical configuration, a single supplicant, an authenticator and an authentication server. B and C are in the internal net- work, D is the authentication server running RADIUS, the switch at the central location acts as an Authenticator connected to PC A and A is a PC outside the controlled port, running Supplicant PAE. In this case, PC A wants to access the services on device B and C, first, it must exchange the authentication message with the authenticator on the port it connected via EAPOL packet. The authenticator transfers the supplicant’s credentials to the authentication ser- ver for verification. If successuf, the authentication server will inform the authenticator about the granted access. Then, PC A is allowed to access B and C via the switch. If there are two switches directly connected together instead of a single one, for the link connecting the two switches, it may have to act in two port roles at the end of the link: authenticator and supplicant, because the traffic is bi-directional.


The following figure shows the procedure of 802.1x authentication. There are steps for the login based on 802.1x port access control management. The pro- tocol used in the right side is EAPOL and the left side is EAP.
At the initial stage, the supplicant A is unauthenticated and a port on
switch acting as an authenticator is in unauthorized state. So the access is blocked in this stage.
Initiating a session. Either authenticator or supplicant can initiate the
message exchange. If supplicant initiates the process, it sends an EAPOL- start packet to the authenticator PAE and the authenticator will immedi- ately respond with an EAP-Request/Identity packet.
The authenticator sends periodically an EAP-Request/Identity to the sup-
plicant requesting the identity that needs to be authenticated.
If the authenticator doesn’t send EAP-Request/Identity, the supplicant will
initiate the process by sending the EAPOL-Start to the authenticator.
Next, the Supplicant replies an EAP-Response/Identity to the authentica-
tor. The authenticator will embed the user ID into RADIUS-Access- Request command and send it to the authentication server for confirming its identity.
After receiving the RADIUS-Access-Request, the authentication server
sends a RADIUS-Access-Challenge to the supplicant to ask for the user password via the authenticator PAE.
The supplicant converts the user password into the credential information,
in MD5 format and replies an EAP-Response with this credential informa- tion as well as the specified authentication algorithm (MD5 or OTP) to the authentication server via the authenticator PAE. As per the value of the type field in the message PDU, the authentication server knows which algorithm should be applied to authenticate the credential information, EAP-MD5 (Message Digest 5) or EAP-OTP (One Time Password) or other algorithms.
If user ID and password are correct, the authentication server will send a
RADIUS-Access-Accept to the authenticator. If not correct, the authenti- cation server will send a RADIUS-Access-Reject.
When the authenticator PAE receives a RADIUS-Access-Accept, it will
send an EAP-Success to the supplicant. At this time, the supplicant is authorized and the port connected to the supplicant and under 802.1x

control is in the authorized state. The supplicant and other devices con- nected to this port can access the network. If the authenticator receives a RADIUS-Access-Reject, it will send an EAP-Failure to the supplicant. This means the supplicant has failed to authenticate. The port it is connected to is in the unauthorized state, the supplicant and the devices connected to this port won’t be allowed to access the network.
When the supplicant issues an EAP-Logoff message to the authentication
server, the port used is set to unauthorized.

The 802.1X “enabled” is the type of authentication supported by the switch. In this mode, the devices connected to this port, once a supplicant is autho- rized, can access the network resources through this port.
The 802.1x Port-based Network Access Control function supported by the switch is more complex, it just supports basic Multihost mode, which can dis- tinguish the device’s MAC address and its VID. The following table is the sum- mary of the combination of the authentication status and the port status versus the status of port mode, set in 802.1x Port mode, port control state, set in 802.1x port setting. Here Entry Authorized means MAC entry is authorized.
Port Mode Port Control Authentication Port Status
Disable Don’t Care Don’t Care Port Uncontrolled
Multihost Auto Successful Port Authorized

Multihost Auto Failure Port Unauthorized
Multihost Force Unauthorized Don’t Care Port Unauthorized
Multihost Force Authorized Don’t Care Port Authorized
The 802.1X Server Configuration is used to configure the global parameters for RADIUS authentication in 802.1X port security application.
Mode:
Enable or disable 802.1X function.
RADIUS server IP address for authentication.
RADIUS UDP Port:
The port number to communicate with a RADIUS server for the authenti- cation service. The valid value ranges 1-65535.
Default port number is 1812.
RADIUS Secret:
The secret key between authentication server and authenticator. It is a string with the length of 1 - 15 characters. The character string may con- tain upper case, lower case and 0-9. It is character sense. It is not allowed to put a blank between any two characters.
Admin State:
This is used to set the operation mode of authorization. There are three types of operation modes supported: Force Unauthorized, Force Authori- zed, Auto.
Force Unauthorized:
The controlled port is forced to hold in the unauthorized state, no matter which EAP negotiation between authenticator and supplicant takes place.
Configuration

Force Authorized:
The controlled port is forced to hold in the authorized state, no mat- ter which EAP negotiation between authenticator and supplicant takes place.
Auto:
If the port is set to be in authorized or unauthorized state depends on the result of the authentication exchange between the authenticatior and supplicant.
Port State:
Shows the port status of authorization.
Re-authenticate:
Using this function all devices connected to this port will have to re- authenticate with username and password when the reauthentication period expires.
Re-authenticate All:
Re-authenticate for all ports at once.
Using this function forces the devices connected to all ports to re- authenticate with username and password when the reauthentication period expires.
Force Reinitialize:
Using this function forces all devices connected to this port to re-authen- ticate with username and password immediately.
Force Reinitialize All:
Using this function forces the devices connected to all ports to re- authenticate with username and password immediately.


Choose the port which you want to show of 802.1X statistics, the screen include Authenticator counters, backend Authenticator counters, dot1x MIB counters and Other statistics.

You can enable or disable the reauthentication function and specify how often a client has to reenter his or her username and password to stay connected to the port.
Statistics · Parameters


Reauthentication Enabled:
Choose whether regular authentication will take place in this port.
Reauthentication Period (1-65535 s):
You can define the time period (in seconds), after a supplicant has to authenticate again. The time period can not be zero.
EAP timeout (1-255 s):
A timeout condition in the exchange between the authenticator and the supplicant. Valid range: 1 -255.
IGMP Snooping lets administrators configure a switch to constrain multicast traffic on certain ports.
IGMP Enabled:
Here you can enable the IGMP function.
Router Ports:
A Port is a router port, if a router is connected which handles multicast routing. Enable here the corresponding ports.

Unregistered IGMP Flooding enabled:
Allows multicats flooding, while the multicast traffic is not registered in the multicast table.
With the IGMP Enable mode being selected, it will list the VLAN ID num- ber.
IGMP Snooping Enabled:
If this function is enabled, the switch can handle IGMP-requests in the network and learns the membership of certain multicast groups if neces- sary.
IGMP Querying Enabled:
If this function is enabled, the switch can distribute IGMP-requests in the network.

Mirror Configuration is used to monitor the traffic in the network. This switch supports one-port mirror multi-ports. For example, we assume that Port A and Port B are Source Ports, and Port C is a Mirror Port, thus the traffic passing through Port A and Port B will be copied to Port C for monitoring purposes.

Source Port:
Sets the port for monitoring. Just tick the check box beside the port x. Valid ports are port 1-24.
Mirror Port:
Use the drop-down menu to select a mirror port
The value “disabled” (default) deactivates this function.


The switch offers powerful QoS function. This function supports VLAN-tagged priority that can make precedence of 8 priorities, and DSCP (Differentiated Services Code Point) on Layer 3 of network framework.
While setting QoS function, please select the QoS Mode in drop-down menu at first. Then you can use 802.1p Priority and DSCP Priority func- tions. In this function, you can enable/disable QoS Mode and set Priority Control, such as: 802.1p and DSCP. The switch only supports Strict Priority. High priority queue is always passed first.
802.1p QoS Mode
This function will affect the priority of VLAN tags. Based on priority of VLAN tags, it can arrange 0~7 priorities, priorities can map to 4 queues of the switch (low, normal, medium, high) and possess different band- width distribution according to your weight setting.
QoS Configuration

Five Prioritize Traffic values are provided: Custom, All Low Priority, All Normal Priority, All Medium Priority, and All High Priority.
The QoS setting would apply to all ports on the switch if one of the following values is selected: All Low Priority, All Normal Priority, All Medium Priority, or All High Priority.
When Custom is selected to prioritize traffic, you may assign a specific Port Number for 802.1p Configuration.
802.1p Configuration
Each Priority can select any of the Queues. In Default, Priority 0 is mapping to Queue normal, Priority 1 is mapping to Queue low, Prio- rity 2 is mapping to Queue low, Priority 3 is mapping to Queue normal, Priority 4 is mapping to Queue medium, Priority 5 is mapping to Queue medium, Priority 6 is mapping to Queue high, and Priority 7 is mapping to Queue high.

DSCP QoS Mode
In the late 1990s, the IETF redefined the meaning of the 8-bit SERVICE TYPE field to accommodate a set of differentiated services (DS). Under the differentiated services interpretation, the first six bits comprise a code- point, which is sometimes abbreviated DSCP, and the last two bits are left unused.
Prioritize Traffic · Port Number

DSCP can form total 64 kinds of traffic classes based on the arrangement of a 6-bit field in DSCP of the IP packet. In the switch, the user is allowed to set up to 64 kinds of these classes that belong to any queue (low, nor- mal, medium, high).
Five Prioritize Traffic values are provided: Custom, All Low Priority, All Normal Priority, All Medium Priority, and All High Priority.
The QoS setting applies to all ports on the switch if one of the follo- wing values is selected: All Low Priority, All Normal Priority, All Medium Priority, or All High Priority.
When Custom is selected for Prioritize Traffic, you may assign a spe- cific Port Number for DSCP Configuration.
802.1p Configuration
64 kinds of priority traffic as mentioned above, can be set up for any Queue (low, normal, medium, high). In default, Priority 0-63 are map- ping to Queue high.

Prioritize Traffic · Port Number

The filter configuration lets administrators assign certain IP addresses or sub- nets to ports on the switch, from which a login on the switch for configuration is allowed.

Source IP Filter:
Mode:
There are three types of modes in this drop-down menu.
Default: Disabled.
Disabled:
Allows all IP Addresses to login and manage the switch.
Static:
Allows the IP Addresses set by the administrator to login and manage the switch.
Allows the IP Address distributed by the DHCP to login and manage the switch.
IP Address:
Setting up the IP Address, it can be one IP Address or a LAN.
IP Mask:
Setting up the IP Subnet Mask related with the IP Address.
DHCP Server Allowed:
Just tick the check box under the port x to allow the DHCP Server on this port.

Ingress and Egress Bandwidth Setting function are used to set up the limit of Ingress or Egress bandwidth for each port.

Traffic Rate Unit
Select the data rate as basis for the rate limit. Possible values from 128 Kbps to 32 Mbps.
Ingress:
Set up the limit of Ingress bandwidth for the port you choose. Incoming traffic will be discarded if the rate exceeds the value you set up in the Data Rate field. Pause frames are also generated if flow control is enabled. The format of the packet limits to unicast, broadcast and multicast. Valid values are multiples (0 to 31) of the traffic rate unit. The resulting limit is shown on the right next to the drop down box.
Egress:
Set up the limit of Egress bandwidth for the port you choose. Outgoing traffic will be discarded if the rate exceeds the value you set up in the Data Rate field. Pause frames are also generated if flow control is enabled. The format of the packet limits to unicast, broadcast and multicast. Valid values are multiples (0 to 31) of the traffic rate unit. The resulting limit is shown on the right next to the drop down box.

Storm Control is used to block unnecessary multicast and broadcast frames that reduce the switch's performance. When the function is enabled and values of storm control are exceeded, multicast and broadcast frames will be dropped.

ICMP Rate:
Enables the ICMP Storm capability. The setting range is 1k-1024k per second. If the amount of ICMP packets reachs this value, ICMP packets will be dropped.
Learn Frames Rate:
To enable the Learn Frames Storm capability. User can use the drop-down menu to select the number of frames. The setting range is 1k~1024k per second.

Broadcast Rate:
To enable the Broadcast Storm capability. User can use the drop-down menu to select the number of frames. The setting range is 1k~1024k per second.
Multicast Rate:
To enable the Multicast Storm capability. User can use the drop-down menu to select the number of frames. The setting range is 1k~1024k per second.
Flooded unicast Rate:
To enable the Flooded unicast Storm capability. User can use the drop- down menu to select the number of frames. The setting range is 1k~1024k per second.
Any Network Management System (NMS) running the Simple Network Management Protocol (SNMP) can manage the managed devices equipped with the SNMP agent, provided that the Management Information Base (MIB) is installed correctly on the managed devices. SNMP is a protocol that is used to govern the transfer of information between the SNMP manager and agent and traverses the Object Identity (OID) of the Management Information Base (MIB), described in the form of Structure Management Information (SMI). The SNMP agent is running on the switch to response the request issued by the SNMP manager.
Basically, it is passive except issuing the trap information. The switch supports to turn on or off the SNMP agent. If you set the field SNMP “Enable”, the SNMP agent will be started up. All supported MIB OIDs, including RMON MIB, can be accessed via the SNMP manager. If the field SNMP is set “Disable”, the SNMP agent will be de-activated, the related Community Name, Trap Host IP Address, Trap and all MIB counters will be ignored.
This function is used to configure SNMP settings, community name, trap host and public traps as well as the throttle of SNMP. A SNMP manager must pass the authentication by identifying both community names, then it can access the MIB information of the target device. So, both parties
SNMP Configuration

must have the same community name. Once completing the setting, click Apply and the setting takes effect.

SNMP enable:
Enables or disables SNMP.
Get/Set/Trap Community:
The community name is used as password for authenticating if the requesting network management unit belongs to the same community group. If they both don’t have the same community name, they don’t belong to the same group. Hence, the requesting network management unit cannot access the device with a different community name via the SNMP protocol; If they both have the same community name, they can talk to each other.
The community name is user-definable variable with a maximum length of 15 characters and is case sensitive. It is not allowed to put any blank in the community name string. Any printable character is allowable. The community name for each function works independently. Each function has its own community name. Say, the community name for READ only works for the READ function and can’t be applied to other functions such as WRITE or TRAP.

System Event:
Select the events for which an SNMP-Trap should be send (Cold Boot and/ or Warm Boot).
TP and Fiber Port Event:
Select the events on the ports for which an SNMP-Trap should be send (Link Up and/or Link Down).
There are five functions contained in the monitoring function: Detailed Stati- stics, LACP Status, RSTP Status, IGMP Status and Ping Status.
Displays the detailed counting number of each port's traffic. All counter infor- mation for one port are shown at one time. Click on a port in the upper screen to show the values of this port. You can activate up to five receive statistics and five transmit statistics at the same time. Confirm your selection with a click on Apply. With Refresh you can update the table.


Rx Packets:
The number of packets received.
Rx Octets:
Total received bytes.
Rx High Priority Packets:
Number of Rx packets classified as high priority.
Rx Low Priority Packets:
Number of Rx packets classified as low priority.
Rx Broadcast:
Shows the number of the received broadcast packets.

Rx Multicast:
Shows the number of received multicast packets.
Rx Broad- and Multicast:
Shows the number of received broadcasts with multicast packets.
Rx Error Packets:
Shows the number of received error packets.
Tx Packets:
The number of packets transmitted.
Tx Octets:
Total transmitted bytes.
Tx High Priority Packets:
Number of Tx packets classified as high priority.
Tx Low Priority Packets:
Number of Tx packets classified as low priority.
Tx Broadcast:
Shows the number of transmitted broadcast packets.
Tx Multicast:
Shows the number of transmitted multicast packets.
Tx Broad- and Multicast:
Shows the number of transmitted broadcasts with multicast packets.
Tx Error Packets:
Shows the number of received error packets.
Rx 64 Bytes:
Number of 64-byte frames in good and bad packets received.
Rx 65-127 Bytes:
Number of 65 ~ 126-byte frames in good and bad packets received.
Rx 128-255 Bytes:
Number of 127 ~ 255-byte frames in good and bad packets received.
Rx 256-511 Bytes:
Number of 256 ~ 511-byte frames in good and bad packets received.
Rx 512-1023 Bytes:
Number of 512 ~ 1023-byte frames in good and bad packets received.

Rx 1024-Bytes:
Number of 1024-max_length-byte frames in good and bad packets recei- ved.
Tx 64 Bytes:
Number of 64-byte frames in good and bad packets transmitted.
Tx 65-127 Bytes:
Number of 65 ~ 126-byte frames in good and bad packets transmitted.
Tx 128-255 Bytes:
Number of 127 ~ 255-byte frames in good and bad packets transmitted.
Tx 256-511 Bytes:
Number of 256 ~ 511-byte frames in good and bad packets transmitted.
Tx 512-1023 Bytes:
Number of 512 ~ 1023-byte frames in good and bad packets transmitted.
Tx 1024-Bytes:
Number of 1024-max_length-byte frames in good and bad packets trans- mitted.
Rx CRC/Alignment:
Number of Alignment errors and CRC error packets received. A cyclic red- undancy check (CRC) checks an inspection value for data, to detect errors in the transmitting process and the storage.
Rx Undersize:
Number of short frames (
Rx Oversize:
Number of long frames (according to max_length register) with valid CRC.
Rx Fragments:
Number of short frames (< 64 bytes) with invalid CRC.
Rx Jabber:
Number of long frames (according to max_length register) with invalid CRC.
Rx Drops:
Frames dropped due to the lack of receiving buffer.
Tx Collisions:
Number of collisions transmitting frames experienced.

Tx Drops:
Number of frames dropped due to excessive collision, late collision, or frame aging.
Tx Overflow:
Number of frames dropped due to the lack of transmitting buffer.
The LACP Status window shows LACP information and status for all ports at the same time. Within the IEEE specification the Link Aggregation Control Pro- tocol (LACP) provides a method to control the bundling of several physical ports together to form a single logical channel.

LACP Aggregation Overview:
Shows the group/port status. Default will set to red sign for “port link down”. Please check legend table below for all references.
LACP Port Status:
Group/Port: Shows the port number.
Normal: See Legend.

RSTP Status shows the present VLAN bridge information and the status of all ports.

Shows VLAN ID.
Bridge ID:
Shows bridge priority setting and bridge ID of the switch, which stands for the MAC address of this switch.
Hello Time:
Shows the current hello time of the root bridge.
Max. Age:
Shows the current root bridge maximum age time.
Forward Delay:
Shows the current root bridge forward delay time.
Topology:
Shows the root bridge’s spanning tree topology.
Root ID:
Shows Root bridge ID of this network segment. If this switch is a root bridge the text: "This switch is Root" will appear.

Internet Group Management Protocol (IGMP) is used to snoop the status of IP multicast groups and display its associated information in both tagged VLAN and non-tagged VLAN networks. When IGMP snooping is enabled in the switch it analyzes all IGMP packets between hosts connected to the switch and multicast router in the network. When a switch hears an IGMP report from a host for a given multicast group, the switch adds the host's port number to the multicast list for that group. When the switch hears an IGMP Leave, it removes the host's port from the table entry.
IGMP Status shows the VLAN ID for each multicast group.

Shows VLAN ID for each multicast group.
Querier:
Shows the group membership queries status.
Queries transmitted:
Shows the number of group membership queries transmitted.
Queries received:
Shows the number of group membership queries received.
V1 Reports:
When a host receives a group membership query, it identifies the groups associated with the query and determines to which groups it belongs. The

host then sets a timer, with a value less than the Max Response Time field in the query, for each group to which it belongs. It calculates the number of times of IGMPV1 report.
When a host leaves a group, it sends a leave group membership message to multicast routers on the network. It shows the leaves number.
Sets up target IP address for ping function and display ping status.
Ping test function is a tool for detecting if the target device is alive or not through the ICMP protocol which abounds with report messages. The switch provides the ping test function to let you know if the target device is available or not. Fill in an IP address and click Apply. The result will show if the target device is available. You can update the table with a click on Refresh.

Ping Parameter:
Target IP address:
Target IP address to ping.

Count:
Use the drop-down menu to set the number of echo requests to send. Four type of number are possible: 1, 5, 10 and 20.
Time Out (in secs):
Use the drop-down menu to set the number of echo requests time out in second. Four type numbers are possible: 1, 5,10 and 20.
Ping Results:
Target IP address:
Shows the active target IP address.
Status:
Shows the result of the ping status.
Received replies:
Shows the received replies number of times.
Request timeouts:
Shows the timeout of request.
Average Response times (In ms):
Shows the average response time in milliseconds.
In this section the functions are described for maintaining the switch.
Warm restart provides the function to restart the device. C
After upgrading software, you must restart the switch to have the new configuration taken in effect.

around 30 seconds to complete the system boot.

Factory default provides the function to retrieve default settings and replace current configuration. Except the IP address setting, all settings will be resto- red to the factory default values when "Factory Default" function is perfor- med. If you want to restore all configurations including the IP address setting to the factory default, please press the "RESET" button on the front panel lon- ger than three seconds.

You can just click the browse button to retrieve the file you want in your sys- tem to upgrade your switch.

You can backup your switch's configuration file into your computer folder in case accident happens. In addition, uploading backup configuration file into a new or a crashed switch can save much time and avoid mistakes.


The switch allows you to log outof the system to prevent other users from using the system without permission. There are three possibilities to log out or be logged out.
the time (in minutes) you set up in the Auto Logout Timer, the switch will log you out automatically. Implicit Logout: If you do not log out and exit the browser, the switch will
automatically log you out. Logout Function: The switch allows administrators to log out manually by
Logout function.


Performance Switching technology Store and forward with latency less than 5 μs
MAC addresses Support of maximal 8K MAC addresses
Throughput maximal 48 Gbps on the backplane
VLAN Port based and IEEE 802.1q tag based VLAN with up to 4096 VLAN and up to 24 active VLANs; Supports ingress and egress packet fil- ter in port based VLAN
LAN protocols Link Aggregation Control Protocol (LACP)
Maximal 12 groups, max 8 member per group, supports DA, SA and DA+SA MAC based trunking with automatic failover
Multicasting Supports IGMP snooping
Spanning Tree Protokoll (STP) / Rapid STP
802.1d/1w
802.3af Features Ports 24x 802.3af PoE ports
Power 185 Watt total power with dynamic load balancing on all ports (i.e. up to 15.4 watt for 12 ports or 7.7 watt für 24 ports)
Priorisation Supports port based priority and PoE status setting
Status information Monitoring via LED, displaying the actual power consumption per port in web interface
Interfaces Ethernet ports 24 ports 10/100/1000 Mbps ethernet, 4 Combo ports TP/SFP 10/ 100/1000 Mbps
Power supply Internal power supply unit (110–230 V, 50-60 Hz)
Housing Robust metal housing, 19" 1HE (440 x 44,2 x 170 mm) with remo- vable mounting brackets, network connectors on the front
Standards CE conformity according to EN 55022, EN 55024, EN 60950
Temperature range 0–40°C; humidity 5–90%; non-condensing
Environment/ Temperature

Accessories 1000Base-SX SFP module, LANCOM SFP-SX-LC1, item no.
61556 1000Base-LX SFP module, LANCOM SFP-LX-LC1, item no.
Support Via Hotline and Internet
Service 5 years

8-pin RJ45 sockets (ISO 8877, EN 60603-7)
Connector Pin Fast Ethernet
2 TBI_DA-
3 R+ BI_DB+
6 RBI_DB-
7 PoE/ -48 V BI_DD+
8 PoE/ -48 V BI_DD-
LANCOM Systems herewith declares that the devices of the type described in this documentation are in agreement with the basic requirements and other relevant regulations of the 1995/5/EC directive.
The CE declarations of conformity for your device can be found on the relevant product page on the LANCOM Web site (www.lancom.eu).
Gigabit Ethernet · 4 PoE/G BI_DC+ · 5 PoE/G BI_DC-

Internet www.lancom.eu
Adenauerstr. 20/B2
LANCOM Systems GmbH · 52146 Würselen · Germany
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.