1. General

Laminotherm is a very thin floor heating to keep laminate and (under conditions) parquet floors at a comfortable temperature. The advantages of Laminotherm are the easy installation and even heating of the surface. Due to the special material characteristics, no hotspots can be produced because good and even heat release is guaranteed.

!!!LET OP!!!

This manual does not replace the floor finishing instructions. This one should also be followed. If any contradictions are mentioned here, please contact Jowitherm Nederland BV.

Laminotherm 2012 — !!!LET OP!!! diagram (page 2)
Fig. 2

Construction of the heating mat

D

The Laminotherm heating mat consists of two heating cables (teflon-insulated) that are included in an aluminium mat. The power cable consists of a two-pole power cable with earth screen. The available assets are 80 and 140 watts/m2 . Laminotherm is supplied ready-to-use in fixed dimensions.

A B

Laminotherm is designed to apply directly under laminate or parquet. Laminotherm can also be installed under carpet in combination with Heatpak. Laminotherm can under no circumstances be used in tiles or other ceramic cq stone floors. Laminotherm cannot be incorporated into a concrete or cement floor. A separation between the Laminotherm and the flooring should always be made, for example heat block floor insulation. Laminotherm cannot be applied under nailed parquet floors. The use of a number of floor finishes is not recommended because of their properties. See the chapter on Suitable floor finishes). For information about suitable floor finishes, please contact Jowitherm Nederland BV, tel +31-74-3762733, or via [email protected]. No heavy furniture shall be placed on the heated parts. Laminotherm shall not be installed on heated floors unless both systems are switched on simultaneously.

A Encased Teflon heating cable B Special aluminium cloth C Heating mat earth D Connection cable 3 m

Electrical instructions:

The installation shall be constructed in accordance with the applicable requirements (NEN1010). The installation shall be connected by an approved installer. The installation shall be equipped with a 30 mA earth leak switch. The heating cable must not be shortened and nodded.

Page 3 of the Laminotherm 2012 user manual — B D
Page 3 · click to enlarge
Page 3

2. Types and technical data available

Type 82 -LM5-200 82 -LM5-400 82 -LM5-600 82 -LM5-800 82 -LM5-1000 82 -LM5-1200 82 -LM5-1400 82 -LM5-1600 82 -LM5-1800 82 -LM5-2000

Dimensions 50 x 200 cm 50 x 400 cm 50 X 600 cm 50x 800 cm 50 × 1000 cm 50 χ 1200 cm 50X 1400 cm 50× 1600 cm 50+ 1800 cm 50-X 2000 cm

Power 80 Watt 160 Watt 240 Watt 320 Watt 400 Watt 480 Watt 560 Watt 640 Watt 720 Watt 800 Watt

Resistance 660 Ohm 330 Ohhm 220 Ohms 165 Ohmm 132 OhM 110 Ohmin 95 Ohma 83 Ohmp 73 Ohme 66 Ohmes

1 m2 2 m2

* Optional mats are available with the same dimensions and a power of 140 w/m2.

Your matt ohmse resistance (taken) Insulation resistance always > 500 MΩ (names)

... Ω ... MΩ

The resistance measured may be -5 + 10% of the declared resistor.

For the technical data of the thermostat and its sensor, please refer to the thermostat manual.

3. Installation example:

A B C D E F G H I

Lamination or parquet Laminotherm Insulation (heat block) Fluid separation foil Construction floor Thermostat Installation tube for connection cable Installation line for floor sensor

F

G H I

A

Laminotherm 2012 — F diagram (page 3)
Fig. 3
Laminotherm 2012 — F diagram (page 3)
Fig. 4
Laminotherm 2012 — F diagram (page 3)
Fig. 5

Instructions:

Laminotherm can be used under standard floor thicknesses of 10-15 mm. Clicking systems using metal clamps between the connections should not be used in connection with possible damage to the heating cable. Lambinate or parquet with integrated insulation or damp guarding should not be used.

B D

E

Show 9 more labels / short text on this page
Surface · 3 m2 · 4 m2 * 5 m2• 6 m2 × 7 m2· 8 m2 x 9 m2 = 10 m2
Page 4 of the Laminotherm 2012 user manual — F F
Page 4 · click to enlarge
Page 4

4. Installation manual

A. Preparation

to prevent flooring. Then roll out the heating mat. This one will stay flat. When laying, keep unheated at least 30 cm from the edge. Nor do heating places under fixed furniture (such as cabinets).

The substrate must be clean, dry and flat. There should be no sharp objects like screws and nails protruding. Fixed furniture, such as cabinets, should not be placed on heated parts of the floor. A laying plan must be drawn indicating where the heating is located, where the sensor cable is located and where the connecting cables are carried to the built-in box.

By cutting the mat and covering it, the heating mat can be easily adjusted to the surface. Use the aluminium strips to leave the parts connected. !!! LET OP !!! Make sure the heating cable is not cut.

B. Connection cable and boxes

The connection cable must be led through an installation line to the built-in box. This can be the box on which the thermostat is mounted, or in case of multiple mats being used, a welding kit. The built-in box on which the thermostat is placed should be positioned at a height of approx. 160 cm from the floor. A welding box may be placed at a height of approx. 30 cm. As the underfloor heating is used as a comfort heater (the temperature of the floor is controlled) it is possible to place the thermostat in a room other than the one that is heated.

Use tape to attach the Laminotherm heating mat to the subfloor

The heating cable must not be cut.The Laminotherm heater mat must not have been shortened, the full length should be shifted. The heating cable shall not be pushed into the installation tube. The connecting cable shall not be installed over the heating mat. Heating mats should never be placed on top of each other (in connection with the risk of overheating). When the heating mats are being removed, each of the parts should be connected to one another with the aluminium strips supplied. This is to guarantee the grounding of the heating mat.

C. Moisturising foil

A dampproof, moisture-resistant film is installed on the construction floor. This film should be applied over the entire surface and slightly stick up at the edges. As a vapour-tight film, the foil supplied by Jowitherm can be used.

TIP

D. Floor insulation

Take photos of the installation of underfloor heating and the floor sensor.

The moisture-resistant foil shall be fitted with a floor insulation (e.g. heat block). The floor insulation is installed over the entire floor area. As the subfloor is better insulated, the operation of the heating will be faster and the heat loss (energy consumption) will be reduced.

Extension sets of the connection cable are also available.

Laminotherm 2012 — TIP diagram (page 4)
Fig. 6
Laminotherm 2012 — TIP diagram (page 4)
Fig. 7

D E

E. Installation of the floor sensor

As the floor sensor is a bit thicker, it is necessary to save the insulation. The sensor should be included in the supplied copper cover. This makes the sensor possible to replace at a later stage. Provide a good reference point, so not under the arrangement of furniture. !!! LET OP !!! The floor sensor should lie between 2 heating cables.

Laminotherm 2012 — D E diagram (page 4)
Fig. 8
Laminotherm 2012 — D E diagram (page 4)
Fig. 9

F F

F. Construction of Laminothermal heating mat

Start with the connection box. Pull the connection cable through the installation tube. Cut the floor insulation under the connection cable and the terminal to thicken in

Page 5 of the Laminotherm 2012 user manual — H F
Page 5 · click to enlarge
Page 5
Laminotherm 2012 — 5.  Underfloor heating system diagram (page 5)
Fig. 10 · 5. Underfloor heating system

Laminotherm 180 degrees covered Laminothermal 90 degrees covered Adjust for interlocks for e.g. furniture Adjustment for extension of connection cable. Extension sets of the cable are also available

The thermostat shall be at maximum power to be switched (usually 3,200 watts of . A higher load should be achieved by using an auxiliary relay. The installation shall be equipped with a 30mA earth leak switch.

You should keep the following items:

Laminotherm 2012 — 5.  Underfloor heating system diagram (page 5)
Fig. 11 · 5. Underfloor heating system

- Type plate of the heating - Laying plan of the heater - Test results - Possible photo plates of the installation - Manuals of the heat and thermostat

5. Underfloor heating system

Laminotherm 2012 — 5.  Underfloor heating system diagram (page 5)
Fig. 12 · 5. Underfloor heating system

Laminotherm is intended to be used as a comfort heating system for the floor. This means that the floor temperature should be measured and controlled by a thermostat with a floor sensor. For example, the EasyTimer clock thermostat. The maximum temperature of lami- naat or wood may be 29 degrees Celcius. Check that the supplier of floor finishes makes further requirements.

Laminotherm 2012 — 5.  Underfloor heating system diagram (page 5)
Fig. 13 · 5. Underfloor heating system

6. Guarantee:

G. Testing the heating mat

Test the resistance and insulation resistance of the heating cable before and after installation. These should be in line with the label. Derogations from -5 and +10 % are allowed.

Jowitherm Nederland BV gives a guarantee of 5 years after the date on which the heating was purchased. In the case of a defective heating cable, the heater shall be repaired or exchanged free of charge. Additional costs are borne by the customer. In the case of a guarantee, it must be shown that the installation has been carried out correctly. The results of the measurements and their plans should be discussed.

H. Floor finish

The laminate or wooden flooring shall be constructed according to the manufacturer's requirements. If there are any uncertainties, ask the supplier of the floor finish to see if the floor is suitable for use in underfloor heating. Carpet can also be used. For this purpose, heatpak must be applied to the heating. Footprint is not recommended.

Laminotherm 2012 — 6.  Guarantee: diagram (page 5)
Fig. 14 · 6. Guarantee:
Laminotherm 2012 — 6.  Guarantee: diagram (page 5)
Fig. 15 · 6. Guarantee:

F F

I. Testing the heating mat

After applying the floor finish test the resistance and insulation resistance of the heating cable. These should be in line with the label. Derogations from -5 and +10 % are allowed.

Laminotherm 2012 — F F diagram (page 5)
Fig. 16

H F

J. Electrical connection

The electrical connection shall be carried out by an approved installer in accordance with the applicable standards. Laminotherm should be connected to a fixed connection box. All mats are connected in parallel, with due consideration being given to:

Ask about the Laminotherm 2012

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Laminotherm 2012

Be the first to ask — other owners or our team will answer.

Original document

Laminotherm 2012 manual PDF

5 pages·1.3 MB·Underfloor·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…