Page 1 of the Honeywell MP09CESBB user manual — Model : MP09 Series: MP09CES, MP09CESBB, MP09CESWW MP10 Series: MP10CES, MP10CESBB, MP10CESWW
Page 1 · click to enlarge
Page 1

Portable Air Conditioner User Manual Read and save these instructions before use

Honeywell MP09CESBB — Portable Air Conditioner User Manual Read and save these instructions before use diagram (page 1)
Fig. 1 · Portable Air Conditioner User Manual Read and save t…

Model : MP09 Series: MP09CES, MP09CESBB, MP09CESWW MP10 Series: MP10CES, MP10CESBB, MP10CESWW

Page 2 of the Honeywell MP09CESBB user manual — USER TIPS
Page 2 · click to enlarge
Page 2

THANK YOU

Congratulations on your purchase of this versatile Honeywell Portable Air Conditioner.

USER TIPS

Honeywell Portable Air Conditioners are ideal for spot cooling. The compressor, condenser and evaporator are housed in a compact unit. The air is filtered, dehumidified and cooled while a flexible air outlet hose sends heat outside. The air conditioner includes a window venting kit. No permanent installation is needed. The unit is easy to move from room to room and offers a truly flexible air conditioning solution.

Auto Evaporation System - The unit automatically evaporates the condensate through the air outlet hose. There is no need to empty the drainage tank except in very high humidity conditions. Read and follow the instructions carefully.

USER TIPS

To ensure optimal efficiency of the product, keep doors and windows closed when it is used as an air conditioner or dehumidifier. If the product is being used with the fan function only, an open window could improve air circulation.

Honeywell MP09CESBB — USER TIPS diagram (page 2)
Fig. 2
Honeywell MP09CESBB — USER TIPS diagram (page 2)
Fig. 3
Honeywell MP09CESBB — USER TIPS diagram (page 2)
Fig. 4

Cooling and Dehumidifying Operation Fan Operation

  • Follow installation instructions to set up the unit. Plug the unit into a properly grounded circuit.
Page 3 of the Honeywell MP09CESBB user manual — PARTS DESCRIPTION
Page 3 · click to enlarge
Page 3

SAFETY

READ AND SAVE THESE INSTRUCTIONS Improper handling can cause serious damage to the appliance.

WARNING:

DO NOT operate the unit with a damaged plug or loose wall outlet. If the power cord is damaged, it

must be replaced by the manufacturer or an authorized service agent.

DO NOT cover the air intake and exhaust when in use.

This appliance is not intended for use by children. Children should be supervised and should not play

on or around the appliance.

DO NOT place objects on or sit on the unit.

Always turn off and unplug the unit when cleaning or servicing.

If service is needed contact an authorized service agent.

Unplug the unit when stored or not in use.

DO NOT run the power cord under carpeting and rugs.

Use caution to prevent tripping on cord.

DO NOT use in areas where gasoline, paint or other flammable goods are stored.

Basic safety precautions should always be followed when using electrical appliances.

This appliance has been manufactured for use in domestic environments and should not be used for

other purposes.

PARTS DESCRIPTION

Honeywell MP09CESBB — PARTS DESCRIPTION diagram (page 3)
Fig. 5
Honeywell MP09CESBB — PARTS DESCRIPTION diagram (page 3)
Fig. 6
1. Control Panel (Incl. Signal Receptor) 2) Air Outlet 3) Handle 4) Casters
5. Air Filter 6) Back Grill 7) Exhaust Hose Connector 8) Power Supply Cord 9) Remote Control
10. Lower Drain Plug (Air Conditioning Mode) 11) Upper Drain Plug (De-humidifier Mode)
Show 12 more labels / short text on this page
• · • · • · • · • · • · • · • · • · • · • · •
Page 4 of the Honeywell MP09CESBB user manual — INSTALLATION
Page 4 · click to enlarge
Page 4

INSTALLATION

Installation Kit:

1. 2. 3. 4. 5.

Window Bracket Kit Window Bracket Panel Adapter Plastic Pin Hose Connector Plastic Hose

1 Set 1 Piece 2 Pieces 1 Piece 1 Piece

x 2 x 1

x 1 x 1

Installation Steps:

1. Install the plastic hose with window bracket adapter and hose connector on both sides. Ensure proper fit on both ends.
Honeywell MP09CESBB — INSTALLATION diagram (page 4)
Fig. 7
Honeywell MP09CESBB — INSTALLATION diagram (page 4)
Fig. 8
2. Adjust the window bracket as per width or height of your window and insert the plastic pins to fix at the desired position. There is a hole where the Plastic Hose will be inserted later. Make sure this hole is not blocked.
Honeywell MP09CESBB — INSTALLATION diagram (page 4)
Fig. 9

Hole for Plastic Hose

3. Connect the plastic hose to the hose connector on back of the unit. Push-in until it is locked in place.

Connect the plastic hose to the hose connector on back of the unit. Slide-in the hose from right to left until it is locked in place.

5. Connect the window bracket to the window.
Honeywell MP09CESBB — INSTALLATION diagram (page 4)
Fig. 10
Honeywell MP09CESBB — INSTALLATION diagram (page 4)
Fig. 11
4. Connect the window bracket to the opposite end of the plastic hose. Ensure that all connections are tight and installed properly.
6. The Portable Air Conditioner is now ready to use.
Honeywell MP09CESBB — INSTALLATION diagram (page 4)
Fig. 12

Plastic Pin

Page 5 of the Honeywell MP09CESBB user manual — TOUCH SCREEN CONTROL PANEL
Page 5 · click to enlarge
Page 5

INSTALLATION (CONTINUED)

NOTE:

1. 2. The supplied exhaust hose can be extended from 30 cm to 120 cm / 12 inches to 47 inches. Do not bend (to the extent shown below) the exhaust hose. A bent hose will block exhaust air and cause the unit to malfunction or shut-off.
Honeywell MP09CESBB — NOTE: diagram (page 5)
Fig. 13
Honeywell MP09CESBB — NOTE: diagram (page 5)
Fig. 14

50 cm / 20”

MAX. 102 cm / 40”

MIN. 36 cm / 14”

RECOMMENDED NOT RECOMMENDED

The length of the exhaust hose is determined by the product specifications. Do not replace or lengthen it as this could cause the unit to malfunction. Make sure the back of the unit is at least 50 cm / 20 inches away from. Do not place the unit in front of curtains or drapes as this could obstruct the airflow.

USE & OPERATION

TOUCH SCREEN CONTROL PANEL

CONTROL PANEL

(5) (1) (4) (6) (7) (2) (3) (3)

(5) (1) (4) (6) (7) (2) (3) (3)

Honeywell MP09CESBB — TOUCH SCREEN CONTROL PANEL diagram (page 5)
Fig. 15

(2) Fan Speed Control

(3) Timer / Temperature Set Controls

(6) Warning Light (when flashing)

POWER CONTROL The Power Control turns the unit on and off.

MODE CONTROL 3 settings: Cool, Dehumidify, Fan. A light will indicate which setting is currently being used.

  • Cooling Mode The unit works as an air conditioner. Adjust fan speed and air temperature to suit your desired comfort level. Temperature setting range is 16°C32°C (61°F89°F).
Show 7 more labels / short text on this page
• · • · (1) Timer Control · (4) Mode Control · (5) Power Control · (7) Timer Light · (7) Timer Light
Page 6 of the Honeywell MP09CESBB user manual — TEMPERATURE / TIMER SET CONTROLS
Page 6 · click to enlarge
Page 6

USE & OPERATION (CONTINUED)

FUNCTION BUTTONS (CONTINUED)

Dehumidifying Mode Air is dehumidified as it passes through the unit, without being in full cooling mode. If room tempera- ture is higher than 25°C (77°F) fan speed can be adjusted; otherwise fan speed is preset to LOW. Note: If the unit will be used mainly as a dehumidifier, do not connect the exhaust hose and let the warm air return in the room. Continuous drainage is then necessary and more efficient (refer to Continuous Draining). Fan Mode For air circulation without air conditioner cooling.

FAN SPEED CONTROL 3 settings: High, Medium and Low.

TIMER CONTROL While the unit is turned on, press the timer button then press the ▼ or ▲ to select the number of hours you would like the unit to continue to run. The unit will turn off automatically. AUTO TURN OFF: While unit is running, press the press the ▼ or ▲ button to select the number of hours you want the unit to run in air conditioning mode. AUTO TURN ON: When unit is in a standby mode (plugged in with power light on), then press the ▼ or ▲ button to select the number of hours until you want the unit to automatically start running.

TEMPERATURE / TIMER SET CONTROLS

Used for adjusting the timer and thermostat. The default display is room temperature. In cooling mode, when ▼ or ▲ button is pressed, the set temperature is displayed and may be adjusted. After 10 seconds the display will revert back to room temperature. Temperature is only adjustable in cool mode. The time is adjustable between 1~24 hours. Note: By pressing both ▼/ ▲ set buttons at the same time, the display will toggle between Celsius and Fahrenheit.

After switching the air conditioner off, you must wait 3 minutes before switching it back on again.

Page 7 of the Honeywell MP09CESBB user manual — ON / OFF
Page 7 · click to enlarge
Page 7

USE & OPERATION (CONTINUED)

REMOTE CONTROL

The functions work the same as the portable air conditioner's Touch Screen Control Panel. All key functions can be accessed from the remote control.

The functions work the same as the portable air conditioner's Control Panel. All key functions can be accessed from the remote control.

Honeywell MP09CESBB — REMOTE CONTROL diagram (page 7)
Fig. 16

ON / OFF

Temperature / Timer Set

Used for adjusting the timer and temperature. When ▼ or ▲ key is pressed in cool mode, the set temperature is displayed and may be adjusted. After 10 seconds the display will revert back to room temperature. Timer setting is available from 1-24 hours by pressing the key ▼ or ▲

  • HIGH
  • MEDIUM
  • LOW

In running mode: Auto switch off In stand-by mode: Auto switch on Press ▼ or ▲ button to adjust the time setting for 1 hour intervals.

Press this button to change the operation mode in the order of:

Battery Installation: Remove the cover on the back of the remote control and insert two AAA batteries with + and - pointing in the proper direction according to the polarity markings.

Honeywell MP09CESBB — ON / OFF diagram (page 7)
Fig. 17

Use only two AAA or IEC R03 1.5V batteries. Remove the batteries if the remote control is not in use for a month or longer. All batteries should be replaced at the same time, do not mix with old batteries. Properly dispose of used batteries.

Show 9 more labels / short text on this page
Power Control · • • · Fan Speed Control · • · Timer Control · Mode Control · Cool Dehumidify · Fan · •
Page 8 of the Honeywell MP09CESBB user manual — CLEANING & MAINTENANCE (CONTINUED)
Page 8 · click to enlarge
Page 8

CLEANING & MAINTENANCE

Appliance Maintenance:

Air filter Air filter

1. 2. Turn off the appliance before disconnecting the power supply. Always clean the appliance with a soft dry cloth.
Honeywell MP09CESBB — CLEANING & MAINTENANCE diagram (page 8)
Fig. 18
Air Filter MaintenanceThe air filter should be cleaned every two weeks. Clean it as follows:
1. 2. Turn off the appliance and remove the air filter . Rinse it in lukewarm water. After cleaning, dry in a shaded and cool place, then reinstall.

CLEANING & MAINTENANCE (CONTINUED)

End of Season Storage & Maintenance: If the appliance will not be used for a long time:

Be sure to drain the left-over water condensation. Remove the lower drain plug and use a shallow pan to collect the water (make sure to replace the drain plug when finished). To dry excess moisture, run the unit in Fan only mode for 30 minutes before storing. Turn off and unplug the air conditioner from the power supply. Remove the air filter and clean with water. Dry the air filter and then reinstall onto the unit. Disconnecting the Window Installation Kit:

2. 3. 4. 5.

Remove the Plastic Hose from the unit by pressing the release button located on the right side of the Hose and then sliding the Hose to the right side.

Remove the Plastic Hose from the unit by pulling away from the unit at the same time.

Remove the Window Bracket, Window Bracket Panel Adapter and Hose Connector.

Remove the Window Bracket, Window Bracket Panel Adapter and Hose Connector.

It is recommended to store the Window Kit parts in a bag together with the Remote Control and placing them together with the air conditioner unit.

It is recommended to store the Window Kit parts in a bag together with the Remote Control and placing them together with the air conditioner unit.

If needed, you can clean the Window Kit with a damp cloth and water before storing. Make sure all parts of the Window Kit are dry before storage.

If needed, you can clean the Window Kit with a damp cloth and water before storing. Make sure all parts of the Window Kit are dry before storage.

Cover the air conditioner with a cloth/ plastic bag before storage, to protect from dust and scratches collecting on the surface of the unit. It is recommended to coil the power cord and store it away from the floor to ensure the cord is protected from bents and creases.

Show 8 more labels / short text on this page
• · • · • · • · • · • · • · •
Page 9 of the Honeywell MP09CESBB user manual — WATER CONDENSATION DRAINAGE
Page 9 · click to enlarge
Page 9

WATER CONDENSATION DRAINAGE

WATER CONDENSATION DRAINAGE

Honeywell MP09CESBB — WATER CONDENSATION DRAINAGE diagram (page 9)
Fig. 19

When there is excess water condensation inside the unit, the air conditioner stops running and shows a warning light. This warning light indicates that the water condensation needs to be drained using the following procedures:

Manual Draining for AC & Dehumidifier Mode Water may need to be drained in high humidity areas.

Unplug the unit from power source. Place a shallow pan under the lower drain plug. See diagram. Remove the lower drain plug. Water will drain out and collect in the shallow pan. After the water is drained, replace the lower drain plug firmly. You can now turn on the unit.

3. 4. 5.

Shallow Pan (Not included)

Continuous Draining for Dehumidifier Mode While using the unit in dehumidifier mode, continuous drainage is recommended.

Honeywell MP09CESBB — WATER CONDENSATION DRAINAGE diagram (page 9)
Fig. 20

Unplug the unit from the power source. Remove the upper drain plug. While doing this operation some residual water may spill so please have a pan to collect the water. Connect the drain connector to a ¾” hose (not included). See diagram. The water can be continuously drained through the hose into a floor drain or sink. You can now turn on the unit.

Lower Drain Plug · Upper Drain Plug · Water Drain Pipe

Page 10 of the Honeywell MP09CESBB user manual — TROUBLESHOOTING GUIDE
Page 10 · click to enlarge
Page 10

TROUBLESHOOTING GUIDE

The following troubleshooting guide addresses the most common problems. If problems persist, call customer service. Unplug and disconnect the appliance from the power source before attempting to troubleshoot.

PROBLEMPOSSIBLE CAUSESOLUTION The air conditioning unit does not start• No electricity. • Batteries in the remote control need to be replaced. • The power cord is not properly plugged in. • The safety LCDI plug has tripped. ( USA / Canada only)• Check for power. • Change remote control batteries. • Remove and reconnect the power cord. • Reset the safety LCDI plug, if problem persists contact our customer support. ( USA / Canada only) Runs a short while only• The thermostat temperature setting is too close to room temperature. • Air outlet is blocked. • There are tight bends in the air exhaust hose.• Lower the set temperature. • Make sure the exhaust hose is properly connected. • Connect exhaust hose as per instructions on page 4. Runs but no cooling• A door or window is open. • The air filter is dirty. • The exhaust hose is detached. • Temperature setting is too high. • Air outlet or intake is blocked.• Make sure the window or door is closed. • Clean the air filter. • Reinstall exhaust hose properly (refer to Installation section). • Reduce temperature setting on control panel. • Remove blockage. Will not run and water full indicator light is ON• Excess water condensation inside the tank.• Drain the water (refer to Water Condensation Drainage).
Page 11 of the Honeywell MP09CESBB user manual — TROUBLESHOOTING GUIDE
Page 11 · click to enlarge
Page 11

JMATEK North America LLC Mahwah, New Jersey 07495 USA Phone: 1-800-474-2147 Email: usinfo@jmatek.com Web: www.jmatek.com

© 2015 JMATEK Limited. All rights reserved. The Honeywell Trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representations or warranties with respect to these products. These products are manufactured by JMATEK Limited.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
The air conditioning unit does not start• No electricity. • Batteries in the remote control need to be replaced. • The power cord is not properly plugged in. • The safety LCDI plug has tripped. ( USA / Canada only)• Check for power. • Change remote control batteries. • Remove and reconnect the power cord. • Reset the safety LCDI plug, if problem persists contact our customer support. ( USA / Canada only) p.10
Runs a short while only• The thermostat temperature setting is too close to room temperature. • Air outlet is blocked. • There are tight bends in the air exhaust hose.• Lower the set temperature. • Make sure the exhaust hose is properly connected. • Connect exhaust hose as per instructions on page 4. p.10
Runs but no cooling• A door or window is open. • The air filter is dirty. • The exhaust hose is detached. • Temperature setting is too high. • Air outlet or intake is blocked.• Make sure the window or door is closed. • Clean the air filter. • Reinstall exhaust hose properly (refer to Installation section). • Reduce temperature setting on control panel. • Remove blockage. p.10
Will not run and water full indicator light is ON• Excess water condensation inside the tank.• Drain the water (refer to Water Condensation Drainage). p.10

Ask about the Honeywell MP09CESBB

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Honeywell MP09CESBB

Be the first to ask — other owners or our team will answer.

Original document

Honeywell MP09CESBB manual PDF

11 pages·678 KB·Air Conditioner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…