User Manual
Honeywell Security











The Galaxy 3 Series alarm system is a microprocessor control system designed using the latest software and hardware technology.
The Galaxy 3 Series meets all your security needs. The technician programming and configuring the system according to your specific requirements.
The device does not contain any components to be maintained by the user. Have the maintenance performed by an experienced installer.
The equipment has been approved under the EU Directive 98/482/EC for Pan-European single terminal connections on the PSTN (Public Switched Telephone Network). However, due to differences between individual PSTNs from different countries, the approval does not provide an unconditional guarantee of proper operation at each PSTn connection point.
In case of problems, you should first contact the equipment supplier.
The Galaxy system is designed to be used with the following nets:
Belgium France Iceland Netherlands Spain
Denmark Greece Italy Norway Sweden
* Germany Great Britain Liechtenstein Austria Switzerland
Finland Ireland Luxembourg Portugal
* Interconnection problems are possible.
Galaxy system used with a net that is not in this list.



The Galaxy alarm system is operated via Galaxi Mk7 LCD control panel (Liquid Crystal Display). You can connect up to 16 servants to the Galaxy 3-144 power stations. You can connect up to 32 servants to the Galaxy 3-520 power stations.
1 2 3 A
4 5 6 B
7 8 9 graft * 0 # esc
Keys (0 - 9)
These keys enter the code, and select and change menu menu templates.
Before you can perform actions on the system, you need to identify yourself using a personal identification number (PIN). This number consists of at least five digits, which you enter with the keys 0 - 9.
The number keys are also used when blocks in the system are programmed so that blocks (zones) can be switched on or off.
These keys are programmed to activate a system option. If you press the key A > press after a valid code has been entered, the full switching procedure will be started. If you press the key < B press after a valid code has been entered, the part-protected enable routine is started.
After selecting a system option, you can select the keys A > or < B use as function keys to forward (A >) or backwards (< B) to be browsed in the menu. If you want to quickly display each item in the list, hold a function key when displaying an option list. This way you can quickly access the desired information.

If you are on the ent-key pressing, the data entered are accepted and processed. The valid actions will be executed and the following option will open.
Press the esc-key to close the current option and return to previous menu level. Any changes made to the option settings will be cancelled. If you are several times on the esc-key press, return to the home screen (also called BANNER).
If you are leaving the building during the period before esc-key pressing, the switch-on procedure is terminated.
With the #-key you can display additional settings for certain menu menu templates, e.g. to adjust the clock speed at the option Time and date.
This key is also used as a coercive button for the user (press the key twice after entering a valid code).
The * key displays additional options for certain menu folders, such as printing the event log or deleting items.
The green power supply LED burns as long as the control gear is connected to the mains. If the voltage fails, the LED will blink slowly. If the battery voltage drops below minimum or a fuse of the central circuit board is broken, the LED will flash quickly.
The banner is the information displayed on the handheld, for example Galaxy 520 V5.00 (with the time and date on the bottom line). This information is always displayed when the system is disabled, unless the menu is consulted or an alarm or Help message is displayed on screen. The installer can change the banner if required. When the system is switched on, the banner is normally empty.
The user code is a unique PIN of at least five digits. The PIN identifies the user at Galaxy alarm panel and provides access to system functions.

Before the system is switched on, make sure that all doors and windows are properly closed, and do not block areas secured by motion detectors.
Code + graft code + A
Enable full
Every digit you enter will be audible and an * appears on the handheld. After all the digits have been entered, press graft or A > to initiate the activation procedure.
A12345678 Blokkn GGG
If the permission to enable blocks is assigned to the PIN, select the blocks you want to enable during the enabled procedure. The status of each block is displayed on the display of the control panel. The following status options are possible:- G = Complete (block is disabled and all zones are closed) O = Open areas (block has been switched off and at least one zone is open) I = Enabled (block turned on) L = Lockout (block locked and cannot be disabled) Enter the number of blocks you want to enable. For example, if you want to enable blocks 2 and 3, press key 2 and 3. The blocks you have selected for enable are displayed on the screen. Press graft to start the enabled procedure for the specified blocks. The Galaxy 3-520 has more than eight blocks. If the user can select blocks, available blocks will be displayed on the control panel when a valid code + A > is introduced. The blocks are indicated with A1 to A8. Use A > and < B to browse the different sets of blocks. If the user is not allowed to select blocks, then after entering the PIN and A > all blocks assigned to the user for enable.
IGG
INSTANCE A12345678 Blokkn GI I
B12345678 Blokkn GI I
Baseline time
If all the zones of the system are closed when the switching on procedure is started, the screen displays the remaining seconds before leaving the building. Leave the building according to the agreed route.
Code + A · Code +A · A key

Sound signal A continuous audible signal shall be generated during the activation period when all zones are closed. If a zone is opened during the set-up period, you will hear an interrupted audible signal. You will also hear the interrupted audible warning during the last 25% of the setting time to indicate that the remaining time is almost up. Opened zones The exit period shall be restarted if one or more zones are opened during the activation period. The number of open zones will appear on the screen and you will be asked to view them. After closing the zones, the exit period will be restarted. An alarm is generated if the enable is not completed before the end of the period Not enabled. (This period is programmed by the installer.) NOTE: Before closing the open zone, you must: esc
3 zones open [] is Watch
press to break the switching procedure. The message [ESC] = STOP Blinks to remind you of this. Last door/Closing button You can complete the setup procedure manually by using last the door or on termination button press. System enabled When the period has expired or you have finished manually, the system waits four seconds before turning on. You will hear two long sound signals to indicate that the system is switched on. The message appears on the handler ENABLED. Next, the banner appears again, or the display becomes blank. Enable part-protected To enable the system partially secured, press the key < B after you enter the PIN. Only zones for which the parameter PARTE. is activated, enabled, which is programmed by the installer. All other setting functions are identical. Cancel Enable You can abort the enabled procedure by using esc-press the key before the system is switched on. Block Name If you want to display the name of the block, press * and # when blocks are displayed on the control panel (e.g. when turning on). The block name is programmed by the installer. Press * and # to return to the display of blocks.
PARTE. INSCH 120
RESTRICTED A12345678 Blocks RRRRRRrrrr
A1 OFFICE AREA R [<] [>] #=CHANGE

You can use MAX user cards/ tags to enable the system. To do this, assign one of the enable options to a MAX user card/ tag. When you hold the MAX card against a MAX reader for five seconds, the programmed MAX function is activated. For example, the MAX function 13 = Parte-e.g. insch is assigned, the system is partially enabled when you activate MAX card function . .
If a user is allowed to select blocks, a handheld must be used to select the block to enable after holding the card against the reader. Double Verification
If a # is assigned to the PIN of a specific user and corresponding MAX card number, double verification must be performed for the user. This means that the PIN must be entered before turning on with the MAX card, and vice versa. Keyprox
A keyprox is a handheld with built-in card reader. These are normally installed in systems using dual verification enable/disabled. Keyprox panels are used as a handheld and MAX reader, as described above, but the card is held at the lower right corner of the control panel, as shown in the following picture:
1 2 3 A
4 5 6 B
7 8 9 graft * 0 # esc

Normal opening Disable is immediately started when the last opening door or a openingsActivating zone. You will hear a slow pulsating sound signal, and must go directly to the handler and enter a valid PIN followed by A>, <B or graft. Users who are allowed to select blocks open the Screen OFF. after entering their PIN. This allows the user to disable specific blocks. When graft is pressed, returned to the INSCHAK screen. Deviation from the access route Go directly to the handler when entering the building. If you enter a secure zone and activate a zone, an alarm will be generated. The police may be warned and the system must be re-enabled. Time overrun Enter a valid PIN before the entry period has expired. If the input time has passed before a valid PIN is entered, an alarm will be generated. You will hear a slow pulsating signal when 75% of the time before entering has passed, to indicate that the remaining time is almost up. Reset alarm You can reset an alarm by entering a valid PIN and on graft press the handstand. Detailed information about the alarm will appear on the handheld. If more than one zone is activated, you can display detailed information by clicking on A > or < B press. Press graft to return to the banner. Certain types of alarms require after resetting the input of a code with proper reset permission. The message Reset Central. Reset requested appears on the handheld to indicate that you need a valid reset code. Reset by manager When you enter a manager type PIN after setting an alarm, followed by a press on graft, the system is re-enabled. Reset by installer Certain types of alarms require an installer to visit. After checking, this installer will then reset the system. In this case, the system cannot be re-enabled until the installer has reset. Disable with MAX cards If one or more blocks assigned to the MAX card are enabled, the blocks will be disabled when holding a card against the Max reader. If applicable, block selection and double verification shall be applied according to the switch-on instructions.
Galaxy 520 V5.00 15.49 MA 18 Nov
4 ALARMS [] is Watch
RESET CENTRAL RESET REQUESTED

When a problem situation occurs while the system is disabled, the warning status is activated. This means that a pulsating audible signal and/or visual warning is generated on the control panel. Enter your code via the handheld and press graft. The problems are reflected. Use the A> and

The Galaxy 3 Series offers various menu options for changing the functional performance of the system.
There are two menu structures:
These options can only be opened by the installer and authorised users, such as main manager code users.
A selection of options from the full menu. The abbreviated menu is accessible by default for all user codes (type 2.3 and above), except the main manager and installer.
u n m g id ello V
o v i n .r b e G r o k r V
u n e m
= 0 1 u n e m le k a h c s n I
y alp si D = 0 2 h n e M
ts e T = 0 3 h n e M
gizji W = 0 4 h n e M
g u r b re v O = 1 1 s e n o Z
y alp si D = 1 2 s e n o Z ts etp o L = 1 3 n e dji T = 1 4 m uta D
= 2 1 n ele k a h c s n I
y alp si D = 2 2 n e g u e he
ts e T = 2 3 g n a gti U
gizji W = 2 4 s e d o C
.v e D = 3 1 .k a h c s n I
y alp si D = 3 2 m e etching y S jitre m o Z = 3 4
.cr o fe G = 4 1 .k a h c s n I
tnir P = 4 2 s eitp O
= 4 4 r o o p s k a ar b n I
le B = 5 1 eitc n u F
X A M = 5 2 n e g u h e
k ol K = 5 4 ti U / n a A
k ol B = 6 4 n e g u r b re v O
.v e D = 7 1 tc eri D
S R = 7 4 g n a g e o T
e m o H ' = 8 1 ' te S
.tallats n I = 8 4 g n a g e o T
Table 1. Menu Options

If you want to open the menu, enter a valid code and graft Press. If there are unresected system alarms, they will be displayed. If there is more than one alarm, the character > will be displayed and you can use the A- and B key to view all problems. If you are not sure, the graft press, open the menu. The menu that is opened (completely or shortened) depends on the user type.
assigned to the user code, are disabled.
The full menu has a hierarchy of four structures. Each structure is accessible for a higher user code type.
The short menu offers users of type 2.3 or higher a selection of up to ten options, numbered from 0 to 9.
Select the desired option by entering the number (0 - 9), or the key A > or < B use to display each option. Like all Galaxy lists, the menu options are repeated at the end of the list, i.e. menu option 9 is followed by menu item 0.
The following options of the short menu are factory settings. Each option is described on the following page.

Purpose This option allows you to bridge zones before setting the system. Only areas that can be covered are shown.
Overridden.
Cross Zone Select Open the abbreviated menu. Option 0=OVERBRUG ZONE appears. Press graft to select this option.
Show selectable zones When you select the option Crossing Zone selects, displays the first zone that can be covered. You can display the selectable zones by pressing the key A> or <B press. You can quickly browse through the areas that can be covered by holding one of these keys.
1004 SECURITY #=OVERB ENT=INSCH
1004 SECURITY BV. ENT= NSCH
Crossing Zones When the zone you want to bridge is displayed on the screen, press #. The screen indicates that the zone is being covered. Then you can use the keys A> and <B same way to select other zones you want to bridge.
# Press. You do not need to switch on the system.
Enable with overridden zones When the list of covered zones is complete, start the activation procedure by graft press. The system is enabled and the screen indicates how many zones are covered. You can also use esc press to return to the menu options. Bridged zones remain covered after you have esc I'm sorry.
the user is registered in the logbook.
Safe Detector Zones If the covered zone is a safe detector zone, all zones of this type (in all blocks) are bridged. The safe detector zones remain closed until you manually re-record them into the system. The safe detectors remain covered when you disable the system.
# · esc

ATM PIN + ent
ATM 1/2/3/4 zones If you want to cross ATM zones, enter one of the ten ATM codes (last 10 users). Select this option by entering an ATM code and click graft press. Use the key A> to browse through the four ATM zone options (ATM1 to ATM4), and select an option by using graft press. A pre-programmed ATM delay time shall be applied before all the ATM zones of the selected ATM zone type are covered. The zones shall be covered during the ATM time-out period. The remaining number of minutes is displayed on the control panel used for bridging. A warning shall be generated ten and five minutes before re-entry. You can extend the ATM time-out period by entering an ATM code and 1=Access Reset select. To manually re-record ATM zones, enter an ATM code and select 2=Restore Access.
[ent] = Select 1=ATM-1
[ent] = Select 2=ATM-2
TOE. VERTR. ATM-2 12 mins
TOE. TIME-OUT ATM-2 10 mins
ATM PIN + ent
Forced. insch (User type 2.3 and above)
Purpose When the option Forced. insch is activated, you can automatically bridge areas that may be covered when they are open at the start of the switching on procedure. Zones covered by this way remain only one period of engagement.
ATM PIN + ent
Forced. select insch Open the abbreviated menu. Press first 1 and then on graft. The screen indicates the number of areas covered and the remaining seconds before turning on.
1= FORC. INSCH [ent] = Select
Non-Bridging Zones Some open zones may not be able to be bridged in the system. If so, the screen shall indicate which zones are open and the exit period shall be restarted. These zones must be closed before you can continue to enable.
2 zone(s) open [] is Watch

Purpose This option will enable the mode Call Function On or off. When the mode Call Function is enabled, zones for which the installer has programmed Bel function are activated at opening.
type used.
2=BEL FUNCTION [ent] = Select
Select Call Function Open the abbreviated menu. Press first 2 and then on graft. The status of the mode appears on the screen Call Function (ON/OFF). Press the key >A to switch between statuses and press graft to accept the selection.
select ON or OFF respectively.
Operation of Call function When the mode Call Function is enabled, the mode remains active until you turn it off again. Areas for which the installer has programmed the Bel function parameter, continue to use this option when they are activated.
enable the system or during an alarm.
Purpose This menu option provides access to mode Display Zones. In addition, you can check the description and current status of each zone using this option.
Select Display Zones Open the abbreviated menu. Press first 3 and then on graft. The data of the first zone (1001) are displayed.
Address The zone address is a unique four-digit address number used for identification and selection, e.g. 1026 - line 1, RIO 02, zone 6.
3= DISPLAY ZONES [ent] = Select
Function The zone function is displayed and identifies the use of the zone, e.g. INBRAAK or BRAND.

Status The current status of the zone is displayed in the form of information about the circuit, for example Open or Closed. The display switches between this information and function information. Description When a zone description is programmed, it appears on the bottom line of the screen. The description consists of alphanumeric text and provides a detailed description of the zone, e.g. Door left wing. Select and View When you select the option Display Zones selects, the first available zone address appears. You can display other zones in a row using the key >A or <B. You can also view the zones by entering the address: enter the line, RIO code and zone number (4 digits). Press # to display the resistance of the circuit in ohm and RIO voltage (in case of hardwiring). Escape Press esc to abort the option and return to the option menu. Display Geh. (User type 2.4 and above)
1021 SECURITY CASHIER BY
Purpose With the option Display Geh. can display the memory. The events are recorded and stored in non-volatile memory with detailed information.
Display Geh. select Open the abbreviated menu. Press first 4 and then on graft. Detailed information on the latest log event will appear.
4=DISPLAY GEH. [ent] = Select
Events The events that can be displayed include information about switching on and off and alarms. Each event is timed and dated.
GH. A12345678 Blokkn NN
GH. A12345678 Blokkn YY
Select Date Keep one of the function keys pressed to quickly browse through the dates in the log. With the key A> browse the dates forward, using the key <B Backwards. If you stop at the desired date, the first event of the relevant date will be displayed.
Show all events You can view all events of a given date by using the function keys A> and <B step by step, browsing the events. * If the user can select blocks, then the blocks are displayed. You can view events for each block by entering the number of the desired block.
MA 20 NOV 1999

Further information With the key # you can display additional information for certain types of events. This information appears on the bottom line. This information includes, inter alia, zone descriptions, user types and the handheld used.
*
Print If a serial printer is connected to the system, you can print memory by pressing *. Prints will be made from the on-screen event to the most recent.
Print (User type 2.4 and above)
Purpose With the option Print you can print the system information on paper. You can only use this option if a serial printer is connected to the system.
Select Print Open the abbreviated menu. Press first 5 and then on graft. Print options appear. Press esc to break the prints. Codes Press 1 to start printing all codes (user number, name, level and length of code).
5 = PRESSURE [ent] = Select
PRINT CODES ESC = STOP
Zones Select the option Zones to print the details of each system zone. The zone address, function and description shall be printed. Press 2 to select this option. Geh. You can print the full log by pressing the key 3 press. A maximum of 1000 events are printed, depending on the panel type. For each event, the date and time of switching on and off as well as the alarms are printed. All You can print all options (CODES, ZONES and GEH.) by using the option ALLE select. Press the key 4 to start the print with user codes. Help Message If you start printing without a printer being connected and on line, the screen indicates that the printer is offline.
GH. PRINT ESC = STOP
ALL PRINTS ESC = STOP
PRINER off-line ESC = STOPPEN

Purpose With the option Running test You can test the zones. There are two options available: 1. All zones can be tested
In both cases, an audible signal indicates an open zone. The test shall be recorded in the logbook. In wireless zones, the strength of the signal received is also shown as a percentage.
6 = LOOP TEST [ent] = Select
Select Running Test Open the abbreviated menu. Press first 6 and then on graft. After you Running test have selected, appears Test all zns or Select zns.
All zns Choose All zns (press key 1) to start the test immediately. You do not need to select zones because all valid areas are tested. You will hear an audible signal every time a zone is opened. When all the zones are closed, you will no longer hear a sound signal.
NO ACCESS
which can be bridged into the system.
Select Zones If you have the option Select zns select by key 2 The first zone in the system appears. You can view all zones in a row using the key >A or <B. When the zone appears that you want to include in the test, press #. Similarly, you can include other zones in the test. When all the desired zones are selected, press graft in Running test Start.
1002 TRACKING ZONE #=TEST ENT=START
test which cannot be bridged.
Aborting walk test If you want to abort the Loop Test, press esc. If you do not, the option remains active until 20 minutes after the last keystroke.
#

Purpose With the option Time and date you can set the time (hours/minutes) and date (day/month/year).
Select Time and Date Open the abbreviated menu. First press 7 and then press graft. After you select the option Time and date have selected, you can select the time or select date by pressing the key A> or <B press.
7 = TIME AND DATE [ent] = Select
Set Time To set the time, press the key A>. The message New Time appears and you must enter the new time (HH:MM). After you have entered the new time, return to the date or time selection screen immediately. Invalid times (more than 23 hours, more than 59 minutes) are not accepted. Press esc to break down the input.
A> <B
NEW TIME --:-- UU:MM
Set Date To set the date, press the button < B. The message New Date appears and you must enter the new date in days, months and years (DD/MM/JJ). After you have entered the new date, the day of the week will appear. Then return to the selection screen for date or time. Invalid dates (for example 32/13/06) are not accepted. Press esc to break down the input.
Adjusting clock speed The speed of the clock can be adjusted. Press the [#] key at the time displayed on display A = Time B = Date. The clock speed can be adjusted by up to 120 seconds per week. If a value between 0 and 120 seconds is entered, this will be added to the expired time per week. When displaying this screen, press the [*] key to deduct the set number of seconds from the expired time once a week. Press the [graft] key to accept the customization set.
15:25 01/03/05 A=TIME B=Date
CLOCK SPEED/WK 010 (0-120) SEC
Enter time · enter date · #

Purpose With the menu option Codes Managers (user type 3.6) can assign, modify and delete the codes that allow users to operate the system and change options. The Codes option contains two submenus:
8 = WIJZIG CODES [ent] = Select
CODES 1 = Page Codes
This option determines the warning period that is assigned to users before the programmed Change PIN- date.
CODES 2 = PIN Waasch
programmed by the installer.
When blocks are activated, users with the manager code have access to block selection by default. The manager can enable and disable the block selection option using the * key. Users with the manager code have access to the short menu by default.
connected to the Galaxy system. This also refers to MAX3, the extended version of MAX.

Select Codes Open the abbreviated menu. Press first 8 and then on graft.
Page Codes After you select the option Codes have selected, press the key 1 om Page Codes The Commission has already taken a decision on the matter. Display a user number with the key A>. Each user number offers options for PIN, level, name, and time zones and blocks (if applicable). When the user number appears for which you want to change settings, press graft to the option Change Code The Commission has already taken a decision on the matter.
8 = WIJZIG CODES [ent] = Select
WEASE CODES 1 = ERROR Codes
Change Code With the option Change Code you can assign a PIN to a user or modify an existing PIN. The PIN shall be a unique number of four, five or six digits. If you assign a double PIN, the message will appear Double Input. The numbers entered appear on the bottom line of the screen. Pressing the * button will allow you to delete the last digit. If you keep pressing the * button, all digits will be deleted. When the correct PIN is assigned, press graft to end the programming and return to previous menu level.
[ent] = Select 1 = Change Code
When a PIN is assigned to a user number, a full box (s) appears on the top line of the screen with detailed user data.
Specifies DUBBLE CODE

Change Nivo Each user is assigned an access level, which determines the menu options available to the user (see Table 1 . . Menu Options . on page 7). When selecting this option, enter the type you want to assign to the user and press graft to end the programming and return to previous menu level. See Table 2 . . Access levels for users .
8 = CODES [ent] = Select
o n e t h c e r s g n a g e T
o v i N
1 )*( 0 . 1 r e c t i n a d e g ,n e g u h e g n s i s e b e
) n e k n il(
2 ) *( 1 . 2 r e k a m n o h c S n ele k a h c s n i n e ella m e ts y s t e h n a K
2 )*( 2 . 2 r e s a p O n ele k a h c stiu n e - n i n e ella m e ts y s t e h n a K
CODES 1 = Page Codes
2. 2 r e kiu r b e G 9 1 - 1 1 s e it p o u n M
2 4. 2 r e kiu r b e G 9 1 - 1 1 s e it p o u n M
2 5. 2 r e kiu r b e G 9 3 - 1 1 s e p o u n M
2 )**( 6 . 3 r e g a n a M 9 4 - 1 1 s e it p o u n m
3 )**( 7 . 3 r u t alla ts nI 1 7 - 1 1 s e it p o u n M
3 )**( 8 . 3 e t o m r 1 7 - 1 1 s e p o u n M
s e it p o u n t o g n a g e
n a v e r i o o t h e d o c e m e R n e r u t alla ts nI,r e g a n a M e D
o vint ts a v e
Table 2. User access levels
[ent] = Select 1 = Change Code
[ent] = Select 2 = Change Nivo
Any valid PIN followed by # # graft (graft can be replaced by the key A> or <B) can be used as a coercive code.
)*( )**(

8 = WIJZIG CODES [ent] = Select
WEASE CODES 1 = ERROR Codes
to the full menu.
Change Name This option allows you to assign a name to the user (maximum 6 characters). Each user code has the name by default Page. The manager code has the name by default MGR. The manager's name cannot be changed. When you select the option Change Name select, appears on the bottom line of the handheld a section with alphanumeric characters that can be assigned to the user name. The cursor flashes on the letter L. Press * to delete the letters of the default name or previous name. After you delete the previous name, use the key A> or <B to move the cursor to the first letter of the name. Then press graft. The selected character appears on the top line. Then do the same for all other letters of the name. With the # key, switch between uppercase, lowercase and system library. Press esc to save and close the name. Time zone Managers can assign time zones to users PIN . Timers are programmed by the installer. Time zones are used to disable the user PIN during periods (ON to OFF) which are programmed in KLOK A and B.
[ent] = Select 3 = Change Code
[ent] = Select 3 = Change Name
001 NAME GEBR. EFG HIJKLMØÖ0 P
[ent] = Select 4 = Timezone
When 4 = TIME ZONE is displayed, press graft. Press the key A> to select the time zone option you want to assign to the PIN. The following time zone options are available:
[ent] = Select 0 = OFF
0=UIT 1=KLOK A 2=KLOK B 3=KLOK A+B The times allocated to Clock A and Clock B can be displayed with the option 45 Toggle clock. Access is not granted as a code assigned to 1=Clock A, 2=Clok B or 3=Cluck A+B is entered outside the assigned periods. In this case, an event of the type Illegal Code log recorded and any outputs programmed as Illegal Code.
Use the A button to browse through the four time zone options.

Temporary codes Through the option Temporary Code you can assign a temporary PIN to a user. When you select this option, enter the number of days (0 .a. 99) that the code remains active. The default setting is 0. This means the code is permanent. A temporary code expires and is removed from the list of codes at midnight after the assigned number of days. A code assigned as temporary code, is marked in the user codes screen with a ^ between the user number and the username, for example 001^ USER.
8 = WIJZIG CODES [ent] = Select
not allocated as temporary code.
CODES 1 = Page Codes
Change PIN If you want to set a user code as Temporary, select the option Temporary Code and press the * key instead of entering the number of days for a temporary code. Press graft to end the programming and return to previous menu level. A code assigned as Temporary, is marked in the user codes screen with a * between the user number and the username, for example 001 * USER. If the function Change Code to the option Temporary Code is enabled for a user, it must define a new PIN after a preset period. If this does not happen, the PIN will expire and it can no longer be used. Through the option PIN Waarsch you can set a warning period (1 - 28 days) to indicate that the PIN needs to be changed. This will ask the user to set a new code when the almost expired code is entered during the PIN warning period (except while disabling the system). The new PIN must be consist of four to six digits and should differ from any other active PIN. The new PIN must be re-introduced for confirmation. If the system accepts the PIN, the user returns to the banner. As at esc is printed or if the new PIN is invalid, the user can continue to use it in normal manner. The next time the PIN is entered, the user is asked to change the PINS again.
[ent] = Select 1 = Change Code
[ent] = Select 5 = Temporary Code
Temporary Code 00 days
Temporary Code days
at the end of the PIN warning period, the PINS will be deleted next time the system is switched off.
Temporary Code days
Code for modifying PIN
2+5

Change Blocks This option will determine which system blocks the user has access to and what control the user controls over the relevant blocks. The option Change Blocks is only available if Blockmode is activated by the installer. Blocks are disabled by default. The blocks assigned to the user are displayed when selecting the option Change Blocks. All users are standard to Block 1. When you press a block number, the corresponding block is assigned to the user. If you are not sure, 2 and 3 Presses, Blocks 2 and 3 are assigned to the user. Als u op 1 When Block 1 is already assigned, Block 1 will be removed from the user code. If the user can select blocks, press *. When all desired blocks are assigned to the user, press graft to end the programming and return to previous menu level.
0 = OVERBRUG ZONE [ent] to Select
8 = WIJZIG CODES [ent] to Select
WEASE CODES 1 = ERROR Codes
[ent] to Select 1 = Change Code
Use the key A> or <B to navigate between the groups. Press 1 - 8 to assign the blocks of the corresponding block to the user.
[ent] to Select 6 = Change Blocks
B1 - 8 9 - 16
Blocks A 1 >A 1
>A
D1 - 8 25 - 32
Block B 1 >B 1
Block B 1 >B 23
Block groups Physical blocks · 1+2+3

Block B1 Ú23 >B
System blocks. This cannot be changed.
MAX No. A unique number of ten digits has been burned with a laser in each MAX card/tag. You assign a MAX card/ tag to a user by giving this number under the option MAX No.. The number identifies the MAX card/tag in the system and refers to the user it is assigned to.
8 = WIJZIG CODES [ent] = Select
WEASE CODES 1 = ERROR Codes
[ent] = Select 1 = Change Code
user code not assigned to a PIN. All other options for this user are valid for the MAX card/tag. You are advised to assign MAX numbers to users who do not need PIN when using the menu option Max Users.
[ent] = Select 7 = MAX No.
When a MAX number is assigned to a user number, a small letter m appears on the top line of the screen with detailed user data.
MAX No. >
If you assign a # to the MAX number, double verification is applied to the max function, in other words user must enter the PIN first. If you assign an asterisk (*) to the MAX number, a second card is required to open doors.
Enter new MAX No. in

MAX Function The MAX card can be assigned to one menu option. User must have permission to open this menu option (based on the assigned user level or after the access level for menu options has been modified by installer).
The default setting is Not used. You assign a new option using the key A> or <B browse until the desired option appears, or by entering the option number directly with the handheld digits. Select the function by clicking graft press.
8 = WIJZIG CODES [ent] = Select
WEAK CODES 1 = User Codes
MAX Control Part The operation of the menu option assigned to the MAX card/ tag can be limited to one handheld. When you select this option, ** appears on the screen to indicate that no control is specified. If you want to specify a handheld, press the key #. The address of the first handheld in the system is displayed. Use the key A> or <B to select the desired handheld and press graft to end programming.
[ent] = Select 1 = Change Code
[ent] = Select 8 = MAX Function
number of the server address indicates the address of the handheld currently used.
MAX Function = NOT USED
MAX Function 12 = TRAFFIC
[ent] = Select 9 = MAX Control
the option is not displayed. If the MAX function results in an action, for example 12 = Enable, the function is performed.
- PART # = Enable
If no handheld is specified (**), the MAX menu option is available on all of the operators sharing the blocks of the Max user. If there is more than one handler, the message will appear Press a key to all valid servants. Press any key to activate the function on the appropriate handheld. If you do not press any key within fifteen seconds, the function will be automatically activated on all controls.
Anti-Passback When the multi-use prevention function is enabled, a card cannot be used more than once within a given period of time with a particular reader. The function .Anti-Passback . can reset one or more of these limitations.
#

PIN Warning With this option, you activate displaying the remaining number of days before expiry date of user codes for which the option PIN Change is on. During the warning period, the user is asked to enter a new code when the almost expired code is entered. The default period is 99 days but you can set any number of days between 1 and 99. If the user has not entered a new PIN at the end of the PIN warning period, the PIN will be erased next time the system is switched off.
8 = WIJZIG CODES [ent] = Select
day of the month. The PIN expires on the first day of the following month.
WEAK CODES 2 = PIN Waarsch
PIN Waarsch 28 (1-28) days
On the first day of each year, summer time is set on the last Sunday in March and winter time on the final Sunday in October.
The option Summer time Works as follows: at 01:00. on the start date the system clock is turned forward to 02:00. At 2:00. on the end date The system clock is reversed to 01:00.
9 = SUMMER [ent] = Select
26 MAA 29 OKT
NEW DATE --/-- DD/MM
The start- and end date can be changed via the code of an authorized user. Press the key A> in start date change, or press the key <B in end date select. The new date must be a valid four-digit date, with the day/month notation (dd/mm).
23 MAA 29 OKT
A=START B=END
26 MAA 27 OKT
2+3+0+3 2+7+1+0 · esc · esc

This option allows you to view an overview of the most recent alarm activations. The option Break-in trail record the details of system activation and shutdown immediately before and after alarm activation, as well as the first five events occurring during alarm activation. This information is stored by the intrusion track function until next time an alarm is triggered. When opening the option press keys A and B To browse through the 7 burglary trails. When you are viewing the option Break-in trail press #, additional information will appear on certain events: user events display the control, user level and current block; if alarm events occur, zone description appears when defined. You can print the information displayed in the Break-in Track by pressing the . With esc you can abort the printing.
44 = INBRAAKSPOOR [ent] = Select
09:30 SUN 01 JAN OUTSCH. MANAGR
Toggle clock (User Type 3.6)
1=Look This feature allows you to view, enable or disable the times programmed for each timer. Use the keys A and B to browse through the programmed times.
45 = ON/OFF CLOSURE = Select
[ent] = Select 1=Look
change with this option.
2=Holiday Days This function allows you to set up a maximum of ten holiday periods. For each holiday period you will enter a start- and end date in with the option 1=Change Days. When you select this option, the start- and end date of holiday period 01 The Commission has also proposed a new approach to the problem of fraud. If no dates have been entered for this period, **/** will appear. If you have start date want to program, press graft . The date view changes to >DD/MM< . Enter a valid four-digit date and press graft to accept the selection. You do not have to enter a year, the day and month is enough.
[ent] = Select 1=Clock A
45 = ON/OFF CLOSURE = Select
Press the key # to the end date The Commission will then carry out the programming procedure for the start date Out.
[ent] = Select 2=Holiday Days
Press the * key to remove a programmed date. The date display returns to **/**.
[ent] = Select 1=Change Days
are programmed by managers and the installer.

The blocks to which the programmed holiday period applies are allocated through the function 2=Acceptions Block.
45 = ON/OFF CLOSURE = Select
When you select the option Allocation Block selects, the blocks currently assigned to the programmed holiday periods are marked with a J Under the block. Under blocks not allocated, a N. All blocks are marked with a J by default. Press the block number to change the status of the block. When all the desired blocks are allocated to holiday periods, press graft to end the programming and return to previous menu level.
[ent] = Select 2=Holiday Days
[ent] = Select 2=Design Block
STATUS A12345678 Blocks YNYYY YN
Then eight blocks. These are displayed on the handheld in four groups of eight blocks. Press A or B to display each of the block groups.
3=View Open If the option Early Open (45.3.2) is activated, the Lockout OFF-time for the next day reduced by the number of minutes (0 - 240) programmed by the installer. This allows you to manually disable the system earlier than usual. There are two functions within this option:
45 = ON/OFF CLOSURE = Select
[ent] = Select 3=Four Open
The function 1= Early displays the time when the system can be switched off manually the next day. This time is the number of minutes from Lockout OFF-time less than the Early Open- period. Time has the 24-hour notation.
[ent] = Select 1= Early
Early Open UU:MM
If blocks are enabled, you can set the early opening time for each block that is enabled with the option Early Open, display by on the key A or B press.
This function only displays the early time as the option Early Open is on. If this option is disabled or no blocks are enabled, the message will appear NO ACCESS.
Using the function 2=View Open you can turn on or off the early opening.
If blocks are enabled, you can enable the blocks individually to allow early opening.
4=Timers With this option you can Timer A and Timer B Enable and disable. If you have a timer The Commission is therefore proposing to amend the proposal for a directive on timer suspended. You cannot use this option to change the programmed times. Both timers are standard 0 = Out. If you want to enable the timers, select your desired timer and change the setting in 1 = To.

5=Let Work With the option Let Work You may authorize a Autoset Extension before the warning period begins.
6=Week work With the option Weekend work disable the system during the weekend. As for Weekend Day a value other than 0 = UIT (the default setting) is programmed, take the Timers on the next programmed weekend day the allocation pattern day Over. This way, for example, a Sunday can use the settings for Autoset and Lockout Timers of a Monday.
45 = ON/OFF CLOSURE = Select
[ent] = Select 6=Week work
are enabled (the default setting is Disabled) to select the weekend day by enabling the user.
[ent] = Select 1=Programm Days
[ent] = Select 1=Weekend Day
When you select the option 1=Wedding Day selects, appears the programmed weekend day. The default setting is 0 = UIT. Use the key A or B to select the day you want and press graft to end programming and return to previous menu level:
[ent] = Select 1=ZA A=Look
0 = OUT OF 1 = SAT 2 = SUN 3 = BOTH (Saturday and Sunday)
The selected weekend day Stay active only once. The option Weekend Day is reset to default UIT set immediately after the assigned day. The option Weekend Day must be assigned each time you want to use the function.
When you select the option 2=Patron Day selects, the programmed timers that are applied when the option Weekend Day selected. The timers of the selected pattern day (Monday to Friday) are applied to the days selected for weekend work.
assigned by the installer.

This option allows a type 3.6 code to cover all zones that can be covered and open at the end of the attachment time in one or more blocks, as one block. All zones in the relevant blocks with the Crossover parameter activated will be covered if you select this option. Blocks can be bridged and re-recorded without the system having to be switched on or off.
When you select the option Block bridge selects, the blocks assigned to the user code and the handler appear as well as the exclusion status of each block (J indicates that it has been covered, N indicates that the block is not covered). If you want to bridge a block, press the corresponding key. The letter below the block number changes N in J. If you want to re-record the block, press the key J re-make change to N.
may select blocks to the option Overbrug Block to be able to open.
be covered from the system as soon as the block is selected.
When you return to the banner, the message will appear ZONES BV On the handstand. Bridged zones remain covered only one switching period, or until you manually re-record them into the system.

This menu option allows you to control connections for remote service. Remote service is a procedure whereby the installer can remotely control the alarm system via a telephone line or similar connection.
With the option 1=Service you can enable the remote service access mode. There are four communication devices available.
47 = RS ACCESS [ent] = Select
0= Internal Modem/Kiezer 1=IMOD 2=Ethernet 3=External Modem /Kieser
[ent] = Select 1= Service
[ent] = Select 0 = Int MDM/KZR
Choose the device used in your system configuration. You can then choose from two additional options:
[ent] = Select 0 = Direct Access
0=Direct Access - When you select this option, a 40 minute access period for the Galaxy panel is set. During this period, the remote service software has direct access to the system. After the software has connected to the panel, this connection can be used indefinitely; there is no maximum duration. When the remote service connection is disconnected, the access period remains active for 15 minutes.
47 = RS ACCESS [ent] = Select
[ent] = Select 1=Service
When you select one of the numbers (1 - 5) and on graft prints, the Galaxy panel selects the pre-programmed phone number that is callback number is set.
[ent] = Select 0= Int MDM/KZR
If no phone number is programmed for the selected number, you will be asked to use the number 1 The Commission has already taken a decision on the matter. Enter the right phone number and press graft. The panel then chooses the number entered.
[ent] = Select 1= TB TEL/NR.-1
should remote service software is active and must be in mode Waiting for a call back are active.

Lose alarm is tricky and can be expensive. And the police may not respond to any more alarms.
Here are nine tips to help you avoid loos alarm.

e n o Z e t u F g n i v jir h c s e B l e B r e v O . t e d
1 0 0 1
2 0 0 1
3 0 0 1
4 0 0 1
5 0 0 1
6 0 0 1
7 0 0 1
8 0 0 1
1 1 0 1
2 1 0 1
3 1 0 1
4 1 0 1
5 1 0 1
6 1 0 1
7 1 0 1
8 1 0 1
RIO ZONE Function Description OVERB Parte-v. Call Function
RIO ZONE Function Description OVERB Parte-v. Call Function

Alarm situation The system is in alarm mode. The alarm must be reset using a valid PIN or card.
Panic. Reset requested When a PA zone (robbery) is activated, the system must be re-enabled using a high level code (such as a manager or installer depending on the level setting for re-abling).
RESET CENTRAL RESET REQUESTED
Reset Central. Reset requested After an alarm is activated, the system must be re-enabled using a code of manager level.
This message appears after a sabotage alarm.
Reset Central. Reset requested The system is set so that it must be switched on by an installer after an alarm has been activated. You need to contact the installer to reset the system before a user can reset its alarm. This is usually the case when the system has been sabotaged and an installer must come on site to check all readers of the system.
INVALID OPTION SELECTED
No access This message appears when a user tries to display or inspect the log but the log is empty, or when the bridge option is selected but the system does not contain any zones that can be covered.
Invalid option The selected option or value entered is invalid or out of range.
This option is not present
Invalid code The entered code is not recorded in the system memory.
This option is not present This option is provided by the installer when specifically required. When you select an option that is not installed, this message will appear.
ESC = CONTINUE
No modules added When closing the installer mode, the panel does not detect any change in the number of readers. Press esc to continue.
Invalid Code

Account No:
· ·



IU6-033 Rev 1 © Copyright Honeywell Security
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.