INSTRUCTIONS FOR USE



Thank you for purchasing this generator from Honda.
This manual describes operation and maintenance of the EX4D/EX5D generator. All information contained in this edition is based on the information available at the time of printing. The illustrations in this manual are based on type B.
Honda Motor Co., Ltd reserves the right to make changes at any time for product improvement purposes without prior notice.
No part of this manual may be reproduced without written permission from Honda.
This manual is to be considered as part of the generator and must be handed over to the new owner when selling the generalator.
Before the generator is put into operation, local laws and regulations must be complied with. If questions arise regarding the operation, consult a qualified electrical specialist.
PLEASE READ THIS USER GUIDE CAREFULLY. Please check out the following symbols and their following notes in particular:
Shows a large possibility of serious or fatal injury if the cues are not followed.
NOTE: Provides helpful information.
Honda generators are built for safe and reliable use when operated according to the owner’s manual. The operation of this generator requires special attention to ensure your own safety and the security of other people.
Careless handling or incorrect use can cause injury to the generator.
Please read this user manual carefully before starting the generator.
If any problems arise, or if you have questions regarding the generator, please consult an authorized Honda dealer.


To ensure safe operation –





Precautionary statements

These stickers inform about potential sources of danger that can cause serious injury. Carefully read the signs and precautionary instructions mentioned in this guide.
If a sticker falls off or is difficult to read, replacement stickers can be purchased from your Honda dealer.


Position of the CE marking and noise level indicator



SECUREMENT
AIR FILTER
FUEL DRAIN SCREW
Write the frame serial number in the following vacancy. This number is required when ordering components.
Frame serial number:

Power supply circuit breaker order interrupter:
ON to obtain AC voltage. The power circuit breaker order interrupter stops automatically when the circuit is overloaded by 20%. Indicator lamp: Lights up when the engine is running and stopping, or when the motor is shut down. Engine switches: For starting and turning off the generator. Operational indicator counter:
The digits on the operating hour counter indicate the total time of generator operating hours. The indicated operating hours are used to maintain the required maintenance intervals. Voltmeters: Displays the voltage generated by the generator. Voltmeter adjusters:
The voltmeter setting controller serves for adjusting the voltage generated. Oil warning lamp: Lights up when the engine oil level is low or if the engine-oil lubrication system has a defect. The motor stops automatically when the battery is disconnected.

VOLTAGE SETTING REGULATORS

Place the parked generator on a flat and fixed floor surface, and check it. It is absolutely necessary to lock the right front wheel by inserting the hand grip provided into the wheel opening.

Opening/closing of the generator panel

NOTE: The oil warning system automatically shuts down the engine before the oil level drops below the safety limit. However, to avoid an unexpected shutdown, the oil level should be checked regularly.
SAE 10W-30 engine oil complies with the regulations of German car manufacturers for API classification CC or CD. (Oils for this classification are marked as CC or CD on the container.)
SAE 10W-30 engine oil is recommended for the general temperature range. Choose the appropriate oil viscosity for average temperature in their range.

Motor oil

Check the fuel indicator.
Fill the tank to its upper level if necessary. Do not fill the tank above the top.
Use diesel fuel only.
Do not use polluted or mixed diesel fuel.
Careful so that no dirt, dust or water enters the fuel tank.
After refueling, the tank cover must be firmly tightened.

Fuel fuel

Ventilation (restart of the engine after fuel is fully depleted)
The generator is equipped with an automatic venting system. After refuelling, the engine can be started again.

Check that the air filter inserts are clean and in good condition. Clean or replace the filter inserts if necessary (page 28). If the generator is operated in very dusty areas, filter inserts should be cleaned more often than indicated in the MAINTENANCE PLAN (page 25).

Air filters

The battery acid level must be between the upper (UPPER) and lower (LOWER) mark. When the acidity level approaches the lower (LOWER) mark, remove the battery cap screws and carefully refill distilled water to the upper level mark (page 29).

Take magnesia milk or salad oil and consult a doctor immediately. • KEEPING OUTSIDE THE RANGE OF CHILDREN.
Battery

Set the engine switch to “ON” and check if the oil warning lamp is illuminated. After checking, set the motor switch to “OFF” again.
If the oil warning lamp does not light up, an authorized Honda dealer must be visited.

Oil warning lamp

Before starting the motor, all electrical loads must first be disconnected from the power outlet.
PREFERRED: In the generator model with wheels, the wheels are easy to lock.


Engine start-up




NOTE: If the motor cannot be shut off, open the maintenance cover by untightening the screw on the bottom and press down the control lever until the engine stops.



Engine shut-off

Connection to the electrical network of a building
If the generator is used as an auxiliary power source, an insulation switch must be installed to interrupt the main power lines of the building when the generator has been connected. The installation must be done by a qualified electrical specialist and must comply with all applicable laws and electrical guidelines.
Incorrect connections to the electrical network of a building can lead to feeding generator current into the main grid and cause serious injuries with potentially fatal outcome for those touching the lines. Necessarily consult the power supply company or an electrical specialist.
NOTE: In some areas, local laws require the registration of generators with power producers. To this end, obtain local regulations for registration and operating conditions.
It is essential to connect the generator to ground when connected devices are earthed.


Connection of electrical consumers
Ensure that all electrical consumers are in order before they are connected to the generator. If a device has abnormalities, becomes sluggish or suddenly stops, turn it off immediately. Disconnect the device from the mains and check whether the failure is due to a defect of the electrical load or if there is an overload on the generator.

Operation:
NOTE: The B-generator shall not be connected to loads with a nominal voltage of 115 V or 230 V. Generator types C and L are intended for loads with nominal voltages between 120 V and 240 V.

Although normally no voltage adjustment is required, fine settings can be performed by rotating the voltage adjusting regulator. Use the generator at the prescribed voltage (except B, C and L type).

(B type)



The oil warning system automatically stops the engine to avoid damage due to poor lubrication.
If this occurs, check the oil level and fill it with oil at low oil levels (see page 10).
The oil warning system is equipped with an automatically operating motor shutdown system that protects the electrical components of the generator when the battery is removed while the engine is running.
Clock switch (C-type only)
The circuit breakers are automatically switched off when the single-circuit is overcharged or if the connected load has a defect. When the circuit breaker is automatically switched off, check the connected device for proper operation and ensure that the nominal load capacity of the circuit before the circuit turns zero will not be exceeded.

Oil warning system

In order to keep the motor in good operating condition, periodic maintenance and adjustment work are required. The maintenance and inspection shall be carried out in accordance with the MAINTENANCE PLAN.
In order to avoid carbon monoxide poisoning, the engine must be stopped before any maintenance. If the engine is operated in a closed or partially enclosed space, dangerous exhaust gas concentrations can build up in the breathing air. If the engine has to run for any reason, provide sufficient ventilation first.
To avoid heavy burns, make sure to cool the engine before maintenance.
Only use original Honda components or equivalent parts in maintenance and repair. Inferior parts can cause damage to the machine.


Fuel line Check every 2. Year (2) (replacement if required)
NOTE: (1) Wait more often when used in dusty environments.
(2) These items must be carried out by your workshop, whether it is
You have the appropriate tools and mechanical skills. For maintenance, please refer to the Honda service guide. (3) In the case of commercial use of the pump, operating hours shall be:
Note to maintain the correct maintenance intervals. (4) Clean every 1,000 operating hours or every 2 years.
Maintenance plan

Drain the oil while the engine is still warm. Only then can a rapid and complete drainage of engine oil be achieved.

Engine oil change

Clogged or partially added filters can cause severe engine damage. The maintenance of the oil filter depends on the quality of the engine and its conditions. It is therefore recommended that the filter be checked and maintained at certain intervals. In difficult conditions of use, maintenance must be carried out more frequently.
(Cleaning) 1. Discharge the engine oil (see page 26). 2. Untwist the two 6 mm screws and remove the oil filter from the engine. 3. Clean the filter in non-combustible or low-flammable solvent. Then allow the filter to dry completely. 4. Re-mount the filter and the filter cover, tightening with both 6 mm screws. 5. Tighten the screws well. 6. Fill the crankcase to the required level with the recommended engine oil.

Oil filter maintenance

If the generator is operated in very dusty areas, the air filter must be cleaned or replaced more often than specified in the MAINTENANCE PLAN.

AIR GUIDANCE
FAN HOUSINGS
Air filter maintenance

Maintenance of the battery Recharged If the generator is operated at too low a battery acid level, sulfation occurs which leads to damage of the battery cells. If a rapid loss of battery fluid is detected, or if the battery is too weak (slow starting or other electrical failure), an authorized Honda dealer must be consulted. Open the generator panel and check acidity levels in each individual battery cell. Make up to the upper mark with distilled water. Never overfill the battery.


Cleaning the battery If the battery poles are contaminated or corrided, remove the battery and clean the battery terminals. 1. Remove the battery stopper. 2. First, take the negative (-) and then the positive (+) battery cable.

POSITIVE (+) BATTERY POLE
3. Remove the battery and clean the battery poles as well as the battery cable clamps with a wire brush or sandpaper. The battery shall be cleaned with an aqueous solution of sodium bicarbonate and warm water. Care must be taken that no water penetrates into the battery cells. After cleaning, the battery must be completely dried. 4. Connect the positive (+) battery cable to the positive(+), and the negative (-) battery wire to the negative(-) batteries pole. Then tighten the screws and nuts well. 5. Treat the battery poles with fat. 6. Finally, attach the battery to the retaining strip.

Discharge of water from the fuel tank
Diesel fuel is very flammable and explosive under certain conditions. Do not smoke and keep open flames or sparks away.
NOTE: The draining of water from the fuel tank must be carried out at low fuel level.
NOTE: Do not turn the fuel drain screw out quickly, otherwise the fuel will shoot out of the drain opening. Slowly turn away.

FUEL DRAIN SCREW

Set the motor switch to “OFF” and remove the key before checking or retrieving the fuses. be replaced. This avoids an unwanted short circuit.
Pull out the old fuse with your fingers and press a new fuse into the clamps.

Replacement of the fuse

The engine becomes very hot during operation and is still hot for some time after being shut off. Allow the engine to cool before it is transported or stored.

Transport

Storage

If the engine is not starting:

No electricity at the power outlets:

Check the electric consumers or equipment for any defect.



Remote control · (installation) · 7-POLLER PLUG CONNECTOR


(Operation) · Engine start-up





* For the operation of the generator, refer to pages 19-23.

NOTE: If the motor cannot be shut off, open the maintenance cover by untightening the screw on the bottom and press down the control lever until the engine stops.

Engine shut-off


Length x width x height 1040 x 590 x 705 mm


Dimensions · Motrur · Generator


Guaranteed sound pressure level (LWA) test according to 2000/14/EC 93 dB —
NOTE: The technical data can be changed without prior notice.
Noise


B-type


F-type


GM type


L-type


C-type




Honda (U.K.) Limited 470 London Road, Slough, Berkshire, SL38QY, United Kingdom
Honda Europe Power Equipment S.A. Pole 45 Rue des Chataigniers 45140 Ormes France
Honda Motor Europe (North) GmbH Spredlinger, Landstraße 166 D-63069 Offenbach/Main Germany
Honda ltalia Industriale S.P.A. Via della Cecchignola, 5/7 00143 ROME Tel: 06-54928-1 Fax: 05-54929-400
Honda (Suisse) S.A. Route des Mouliéres 10 Case Postale Ch 1214 Vernier-Geneve, Switzerland
Honda Nederland BV Nikkelstraat 17 2984 AM Ridderkerk Netherlands
Honda Austria GMBH Honda Street 1 A-2351 Wiener Neudorf Austria
Honda Power Equipment Sweden A.B. Ostmästargränd 8 Stockholm-Arsta Sweden
Honda Produtos De Força, Portugal, SA Lugar da Abrunheira S. Pedro de Penaferrim 2710 Sintra, Portugal
Berema A/S Berghagan 5, Langhus Box 454, 1401 Ski Norway
For Europe


TIMA PRODUCTS A/S Tårnfalkevej 16, Postboks 511 DK 2650 Hvidovre Denmark
Greens Polig. Industrial Congost 08530, La Garriga (Barcelona), Spain
Apartado de Correos, num 206 Santa Cruz de Tenerife Canary Island
The Associated Motors Company Ltd 148, Rue D’Argens, Msida Malta
Two Wheels Ltd Crosslands Business Park, Ballymount Road, Dublin 12, Ireland
General Automotive Co., SA P.O. P.O. Box 1200, 101 73 Athens Greece
BG Technik s.r.o Radlická 117/520 158 01 Praha 5 Czech Republic
Aries Power Equipment Ltd 01-493 Warszawa, ul Wroclawska 25a Poland
Honda Canada Inc. 715 Milner Avenue Toronto ON M1B 2K8
Honda Australia Motorcycle and Power Equipment Pty. Ltd
1954-1956 Hume Highway Campbellfield Victoria 3061
for Europe (continued) · for Canada · for Australia