EN
Honda logo
Official user manual

Honda EM5000is

104 pages·4.1 MB·Generator·PDF·ENDEFRITNLJA
Honda EM5000is
Table of Contents 106 sections COVER · INTRODUCTION · A FEW WORDS ABOUT SAFETY · CONTENTS · … ShowHide
COVERp.1INTRODUCTIONp.3A FEW WORDS ABOUT SAFETYp.4CONTENTSp.5GENERATOR SAFETYp.8IMPORTANT SAFETY INFORMATIONp.8SAFETY LABEL LOCATIONSp.11CONTROLS & FEATURESp.12COMPONENT & CONTROL LOCATIONSp.12CONTROLSp.14FUEL VALVE LEVERp.14ENGINE SWITCHp.14STARTER GRIPp.15ECO-THROTTLE™ SWITCHp.15VOLTAGE SELECTOR SWITCHp.16AC CIRCUIT PROTECTORSp.16FOLDING HANDLEp.17FEATURESp.18GROUND TERMINALp.18OUTPUT INDICATORp.19OVERLOAD INDICATORp.19OIL ALERT® INDICATORp.20I-MONITOR™p.21FUEL GAUGEp.24BEFORE OPERATIONp.25ARE YOU READY TO GET STARTED?p.25IS YOUR GENERATOR READY TO GO?p.26OPERATIONp.28SAFE OPERATING PRECAUTIONSp.28FREQUENCY OF USEp.29STARTING THE ENGINEp.29STOPPING THE ENGINEp.33AC OPERATIONp.35AC APPLICATIONSp.37AC RECEPTACLE SELECTIONp.38POWER PRODUCING CIRCUITSp.38VOLTAGE SELECTOR SWITCHp.39ECO-THROTTLE SYSTEMp.40STANDBY POWERp.41CONNECTIONS TO A BUILDING'S ELECTRICAL SYSTEMp.41SYSTEM GROUNDp.41SPECIAL REQUIREMENTSp.42SERVICING YOUR GENERATORp.43THE IMPORTANCE OF MAINTENANCEp.43MAINTENANCE SAFETYp.44MAINTENANCE SCHEDULEp.45REFUELINGp.46FUEL RECOMMENDATIONSp.47ENGINE OIL LEVEL CHECKp.48ENGINE OIL CHANGEp.49ENGINE OIL RECOMMENDATIONSp.50AIR CLEANER SERVICEp.51FOAM AIR FILTER CLEANINGp.52SEDIMENT CUP CLEANINGp.53SPARK PLUG SERVICEp.54SPARK ARRESTER SERVICEp.56BATTERY SERVICEp.58EMERGENCY PROCEDURESp.58BATTERY REMOVALp.59BATTERY CHARGINGp.60BATTERY INSTALLATIONp.60FUSEp.61STORAGEp.62STORAGE PREPARATIONp.62CLEANINGp.62FUELp.62ENGINE OILp.65BATTERYp.65STORAGE PRECAUTIONSp.66REMOVAL FROM STORAGEp.66TRANSPORTINGp.67TAKING CARE OF UNEXPECTED PROBLEMSp.68ENGINE PROBLEMSp.68GENERATOR PROBLEMSp.70TECHNICAL & CONSUMER INFORMATIONp.71TECHNICAL INFORMATIONp.71SERIAL NUMBER LOCATIONp.71CARBURETOR MODIFICATION FOR HIGH ALTITUDE OPERATIONp.72EMISSION CONTROL SYSTEM INFORMATIONp.73AIR INDEXp.76SPECIFICATIONSp.77TUNEUP SPECIFICATIONSp.78WIRING DIAGRAMp.79CONSUMER INFORMATIONp.80Honda PUBLICATIONSp.80DEALER LOCATOR INFORMATIONp.81CUSTOMER SERVICE INFORMATIONp.81ASSEMBLYp.82SAFETYp.82THE IMPORTANCE OF PROPER ASSEMBLYp.82IMPORTANT SAFETY PRECAUTIONSp.83ASSEMBLYp.84UNPACKINGp.84LOOSE PARTSp.84WHEEL KIT INSTALLATIONp.85HANDLE INSTALLATIONp.86REAR BAR INSTALLATIONp.87BATTERYp.88ENGINE OILp.90FUELp.90BEFORE OPERATIONp.91OPTIONAL PARTSp.92REMOTE CONTROL KITp.92HANGER KITp.95INDEXp.96QUICK REFERENCE INFORMATIONp.103
Page 1 of the Honda EM5000is user manual — COVER
Page 1 · click to enlarge
Page 1
Honda EM5000is — COVER diagram (page 1)
Fig. 1
Honda EM5000is — COVER diagram (page 1)
Fig. 2
Honda EM5000is — COVER diagram (page 1)
Fig. 3
Page 2 of the Honda EM5000is user manual — COVER
Page 2 · click to enlarge
Page 2

The engine exhaust from this product contains chemicals known to the State

of California to cause cancer, birth defects or other reproductive harm.

Exhaust contains poisonous carbon monoxide gas that can build up to dangerous levels in closed areas. Breathing carbon monoxide can cause unconsciousness or death.

Never run the generator in a closed, or even partly closed area where people may be present.

Keep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should remain with the generator if resold.

The information and specifications included in this publication were in effect at the time of approval for printing. Honda Motor Co., Ltd. reserves the right, however, to discontinue or change specifications or design at any time without notice and without incurring any obligation whatever.

Page 3 of the Honda EM5000is user manual — INTRODUCTION
Page 3 · click to enlarge
Page 3

INTRODUCTION

Congratulations on your selection of a Honda generator. We are certain you will be pleased with your purchase of one of the finest generators on the market.

We want to help you get the best results from your new generator and to operate it safely. This manual contains all the information on how to do that; please read it carefully.

As you read this manual, you will find information preceded by a

symbol. That information is intended to help you avoid damage to your generator, other property, or the environment.

We suggest you read the Distributor’s Limited Warranty to fully understand its coverage and your responsibilities of ownership. The Distributor’s Limited Warranty is a separate document that should have been given to you by your dealer.

When your generator needs scheduled maintenance, keep in mind that your Honda servicing dealer is specially trained in servicing Honda generators and is supported by the parts and service divisions of American Honda. Your Honda servicing dealer is dedicated to your satisfaction and will be pleased to answer your questions and concerns.

Best Wishes, Honda Motor Co., Ltd.

Page 4 of the Honda EM5000is user manual — A FEW WORDS ABOUT SAFETY
Page 4 · click to enlarge
Page 4

A FEW WORDS ABOUT SAFETY

Your safety and the safety of others are very important. And using this generator safely is an important responsibility.

To help you make informed decisions about safety, we have provided operating procedures and other information on labels and in this manual. This information alerts you to potential hazards that could hurt you or others.

Of course, it is not practical or possible to warn you about all the hazards associated with operating or maintaining a generator. You must use your own good judgement.

You will find important safety information in a variety of forms, including:

on the generator.

preceded by a safety alert symbol and one of three signal words, DANGER, WARNING, or CAUTION.

These signal words mean:

be or if you don’t follow instructions.

You WILL KILLED SERIOUSLY HURT

be or if you don’t follow instructions.

You CAN KILLED SERIOUSLY HURT

be if you don’t follow instructions.

such as IMPORTANT SAFETY INFORMATION.

GENERATOR SAFETY.

how to use this generator correctly and safely.

This entire book is filled with important safety information please read it carefully.

Show 13 more labels / short text on this page
Safety Labels · - · Safety Messages · - · You CAN HURT · Safety Headings · - · Safety Section · - · such as · Instructions · - · -
Page 5 of the Honda EM5000is user manual — Table of Contents
Page 5 · Contents
Contents

Contents

COVERp.1INTRODUCTIONp.3A FEW WORDS ABOUT SAFETYp.4CONTENTSp.5GENERATOR SAFETYp.8IMPORTANT SAFETY INFORMATIONp.8SAFETY LABEL LOCATIONSp.11CONTROLS & FEATURESp.12COMPONENT & CONTROL LOCATIONSp.12CONTROLSp.14FUEL VALVE LEVERp.14ENGINE SWITCHp.14STARTER GRIPp.15ECO-THROTTLE™ SWITCHp.15VOLTAGE SELECTOR SWITCHp.16AC CIRCUIT PROTECTORSp.16FOLDING HANDLEp.17FEATURESp.18GROUND TERMINALp.18OUTPUT INDICATORp.19OVERLOAD INDICATORp.19OIL ALERT® INDICATORp.20I-MONITOR™p.21FUEL GAUGEp.24BEFORE OPERATIONp.25ARE YOU READY TO GET STARTED?p.25IS YOUR GENERATOR READY TO GO?p.26OPERATIONp.28SAFE OPERATING PRECAUTIONSp.28FREQUENCY OF USEp.29STARTING THE ENGINEp.29STOPPING THE ENGINEp.33AC OPERATIONp.35AC APPLICATIONSp.37AC RECEPTACLE SELECTIONp.38POWER PRODUCING CIRCUITSp.38VOLTAGE SELECTOR SWITCHp.39ECO-THROTTLE SYSTEMp.40STANDBY POWERp.41CONNECTIONS TO A BUILDING'S ELECTRICAL SYSTEMp.41SYSTEM GROUNDp.41SPECIAL REQUIREMENTSp.42SERVICING YOUR GENERATORp.43THE IMPORTANCE OF MAINTENANCEp.43MAINTENANCE SAFETYp.44MAINTENANCE SCHEDULEp.45REFUELINGp.46FUEL RECOMMENDATIONSp.47ENGINE OIL LEVEL CHECKp.48ENGINE OIL CHANGEp.49ENGINE OIL RECOMMENDATIONSp.50AIR CLEANER SERVICEp.51FOAM AIR FILTER CLEANINGp.52SEDIMENT CUP CLEANINGp.53SPARK PLUG SERVICEp.54SPARK ARRESTER SERVICEp.56BATTERY SERVICEp.58EMERGENCY PROCEDURESp.58BATTERY REMOVALp.59BATTERY CHARGINGp.60BATTERY INSTALLATIONp.60FUSEp.61STORAGEp.62STORAGE PREPARATIONp.62CLEANINGp.62FUELp.62ENGINE OILp.65BATTERYp.65STORAGE PRECAUTIONSp.66REMOVAL FROM STORAGEp.66TRANSPORTINGp.67TAKING CARE OF UNEXPECTED PROBLEMSp.68ENGINE PROBLEMSp.68GENERATOR PROBLEMSp.70TECHNICAL & CONSUMER INFORMATIONp.71TECHNICAL INFORMATIONp.71SERIAL NUMBER LOCATIONp.71CARBURETOR MODIFICATION FOR HIGH ALTITUDE OPERATIONp.72EMISSION CONTROL SYSTEM INFORMATIONp.73AIR INDEXp.76SPECIFICATIONSp.77TUNEUP SPECIFICATIONSp.78WIRING DIAGRAMp.79CONSUMER INFORMATIONp.80Honda PUBLICATIONSp.80DEALER LOCATOR INFORMATIONp.81CUSTOMER SERVICE INFORMATIONp.81ASSEMBLYp.82SAFETYp.82THE IMPORTANCE OF PROPER ASSEMBLYp.82IMPORTANT SAFETY PRECAUTIONSp.83ASSEMBLYp.84UNPACKINGp.84LOOSE PARTSp.84WHEEL KIT INSTALLATIONp.85HANDLE INSTALLATIONp.86REAR BAR INSTALLATIONp.87BATTERYp.88ENGINE OILp.90FUELp.90BEFORE OPERATIONp.91OPTIONAL PARTSp.92REMOTE CONTROL KITp.92HANGER KITp.95INDEXp.96QUICK REFERENCE INFORMATIONp.103
Page 8 of the Honda EM5000is user manual — IMPORTANT SAFETY INFORMATION
Page 8 · click to enlarge
Page 8

GENERATOR SAFETY

IMPORTANT SAFETY INFORMATION

Honda generators are designed for use with electrical equipment that has suitable power requirements. Other uses can result in injury to the operator or damage to the generator and other property. Most injuries or property damage can be prevented if you follow all instructions in this manual and on the generator. The most common hazards are discussed below, along with the best way to protect yourself and others.

Know how to stop the generator quickly in case of emergency.

Understand the use of all generator controls, output receptacles, and connections.

Be sure that anyone who operates the generator receives proper instruction. Do not let children operate the generator without parental supervision.

Exhaust contains poisonous carbon monoxide, a colorless, odorless gas. Breathing carbon monoxide can cause loss of consciousness and may lead to death.

If you run the generator in a confined or even partly enclosed area, the air you breathe could contain dangerous amount of exhaust gas.

Never run your generator inside a garage, house, or near open windows or doors.

Operator Responsibility · Carbon Monoxide Hazards

Page 9 of the Honda EM5000is user manual — GENERATOR SAFETY
Page 9 · click to enlarge
Page 9

GENERATOR SAFETY

The generator produces enough electric power to cause a serious shock or electrocution if misused.

Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution. Keep the generator dry.

If the generator is stored outdoors, unprotected from the weather, check all of the electrical components on the control panel before each use. Moisture or ice can cause a malfunction or short circuit in electrical components that could result in electrocution.

Do not connect to a building’s electrical system unless an isolation switch has been installed by a qualified electrician.

Fire and Burn Hazards

The exhaust system gets hot enough to ignite some materials.

Keep the generator at least 3 feet (1 meter) away from buildings and other equipment during operation. Do not enclose the generator in any structure. Keep flammable materials away from the generator.

The muffler becomes very hot during operation and remains hot for a while after stopping the engine. Be careful not to touch the muffler while it is hot. Let the engine cool before storing the generator indoors.

Electric Shock Hazards · - · - -

Page 10 of the Honda EM5000is user manual — GENERATOR SAFETY
Page 10 · click to enlarge
Page 10

GENERATOR SAFETY

Gasoline is extremely flammable, and gasoline vapor can explode. Allow the engine to cool if the generator has been in operation. Refuel only outdoors in a well-ventilated area with the engine off. Do not refuel during operation. Do not overfill the fuel tank. Never smoke near gasoline, and keep other flames and sparks away. Always store gasoline in an approved container. Make sure that any spilled fuel has been wiped up before starting the engine.

Refuel With Care

Page 11 of the Honda EM5000is user manual — SAFETY LABEL LOCATIONS
Page 11 · click to enlarge
Page 11

GENERATOR SAFETY

SAFETY LABEL LOCATIONS

These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda servicing dealer for a replacement.

Honda EM5000is — SAFETY LABEL LOCATIONS diagram (page 11)
Fig. 4
Page 12 of the Honda EM5000is user manual — OUTPUT INDICATOR
Page 12 · click to enlarge
Page 12

CONTROLS & FEATURES

COMPONENT & CONTROL LOCATIONS

Use the illustrations on these pages to locate and identify the most frequently used controls.

CIRCUIT PROTECTORS OIL ALERT INDICATOR

Honda EM5000is — CIRCUIT PROTECTORS OIL ALERT INDICATOR diagram (page 12)
Fig. 5

OUTPUT INDICATOR

RECEPTACLES

ENGINE SWITCH

VOLTAGE SELECTOR SWITCH

Honda EM5000is — OUTPUT INDICATOR diagram (page 12)
Fig. 6

i-MONITOR

Page 13 of the Honda EM5000is user manual — STARTER GRIP
Page 13 · click to enlarge
Page 13

CONTROL & FEATURES

FUEL TANK CAP

Honda EM5000is — FUEL TANK CAP diagram (page 13)
Fig. 7

SPARK PLUG INSPECTION COVER

HANDLE

BATTERY TRAY (Inside maintenance cover)

WHEEL

MAINTENANCE COVER

AIR CLEANER

STAND

Honda EM5000is — WHEEL diagram (page 13)
Fig. 8

STARTER GRIP

GROUND TERMINAL

MUFFLER TIP

OIL FILLER CAP/DIPSTICK

Page 14 of the Honda EM5000is user manual — REMOTE
Page 14 · click to enlarge
Page 14

CONTROL & FEATURES

CONTROLS

The fuel valve lever is located on the control panel.

ON

The fuel valve lever must be in the ON position for the engine to run.

OFF

After stopping the engine, turn the fuel valve lever to the OFF position.

FUEL VALVE LEVER

The engine switch controls the ignition system, and it operates the electric starter.

Honda EM5000is — FUEL VALVE LEVER diagram (page 14)
Fig. 9

OFF Stops the engine. The engine switch key can be removed/inserted.

ON Running position, and for starting with the recoil starter.

ENGINE SWITCH

START Operates the electric starter.

Honda EM5000is — ENGINE SWITCH diagram (page 14)
Fig. 10

REMOTE For using the remote control kit (optional parts).

REMOTE

ENGINE SWITCH

Show 6 more labels / short text on this page
Fuel Valve Lever · Engine Switch · - · - · - · -
Page 15 of the Honda EM5000is user manual — ECO-THROTTLE SWITCH
Page 15 · click to enlarge
Page 15

CONTROL & FEATURES

STARTER GRIP

Pulling the starter grip operates the recoil starter to crank the engine for starting.

Honda EM5000is — STARTER GRIP diagram (page 15)
Fig. 11

Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter. Do not let the starter rope rub against the generator body, or the rope will wear out prematurely.

TM

The Eco-Throttle system automatically reduces engine speed when all loads are turned off or disconnected. When appliances are turned on or reconnected, the engine returns to the proper speed to power the electrical load.

If high electrical loads are connected simultaneously, turn the Eco-Throttle switch to the OFF position to reduce voltage changes.

ON Recommended to minimize fuel consumption and further reduce noise levels when a reduced load or no load is applied to the generator.

ECO-THROTTLE SWITCH

Honda EM5000is — ECO-THROTTLE SWITCH diagram (page 15)
Fig. 12

OFF The Eco-Throttle system does not operate. Generator operates at full output.

Show 4 more labels / short text on this page
Starter Grip · Eco-Throttle Switch · - · -
Page 16 of the Honda EM5000is user manual — AC CIRCUIT PROTECTOR
Page 16 · click to enlarge
Page 16

CONTROL & FEATURES

Always disconnect or turn OFF all appliances or tools connected to the generator before changing the voltage selector switch position.

The voltage selector switch switches generator output to produce ‘‘120 V ONLY’’ or ‘‘120 V/240 V.’’ If a 240 V appliance is connected to the 4-prong receptacle, the switch must be in the ‘‘120 V/240 V’’ position. If only a 120 V appliance is being connected to any of the 120 V 3-prong receptacles, select the ‘‘120 V ONLY’’ position.

Select the voltage before starting the engine.

120/240 V:

The 120 V and 120 V/240 V receptacles can be used simultaneously.

120 V ONLY:

ONLY the 120 V receptacles can be used. Do not use the 120 V/240 V receptacle in this position. The most power will be available at the 30 A 120 V locking plug receptacle.

Honda EM5000is — 120 V ONLY: diagram (page 16)
Fig. 13

VOLTAGE SELECTOR SWITCH

120 V/240 V

120 V ONLY

The AC circuit protectors will automatically switch OFF if there is a short circuit or a significant overload of the generator at each receptacle. If an AC circuit protector switches OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the AC circuit protector ON.

CIRCUIT PROTECTOR for Receptacle

Honda EM5000is — VOLTAGE SELECTOR SWITCH diagram (page 16)
Fig. 14

AC CIRCUIT PROTECTOR

ON

OFF

PUSH

120/240 V 30 A

Voltage Selector Switch · Switch Position · AC Circuit Protectors

Page 17 of the Honda EM5000is user manual — HANDLE LOCK LEVER
Page 17 · click to enlarge
Page 17

CONTROL & FEATURES

The foldable handle is intended for ease of transportation and should be folded when the generator is stationary. Do not rest objects on the extended handle.

To Extend The Handle

Lift handle upward. Lock levers will lock and secure the handle into place.

To Fold The Handle

Lower the handle. Press handle lock levers downward. 2. 1.

HANDLE LOCK LEVER

HANDLE

Folding Handle · Handle transport position · Generator stationary position

Page 18 of the Honda EM5000is user manual — GROUND TERMINAL
Page 18 · click to enlarge
Page 18

CONTROL & FEATURES

FEATURES

The ground terminal is connected to the frame of the generator, the metal non-current-carrying parts of the generator, and the ground terminals of each receptacle.

Before using the ground terminal, consult a qualified electrician, electrical inspector, or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator.

GROUND TERMINAL

Ground Terminal

Page 19 of the Honda EM5000is user manual — OVERLOAD INDICATOR (RED)
Page 19 · click to enlarge
Page 19

CONTROL & FEATURES

The green output indicator is illuminated when the generator is operating normally. It indicates that the generator is producing electrical power at the receptacles.

OUTPUT INDICATOR (GREEN)

Honda EM5000is — OUTPUT INDICATOR (GREEN) diagram (page 19)
Fig. 15

If the generator is overloaded, or if there is a short circuit in a connected appliance, or if the inverter is overheated, the red overload indicator will go ON. When the generator is operating overloaded, the red overload indicator will stay ON and, after about five seconds, current to the connected appliance(s) will shut off, and the green output indicator will go OFF.

OVERLOAD INDICATOR (RED)

Honda EM5000is — OVERLOAD INDICATOR (RED) diagram (page 19)
Fig. 16

Output Indicator · Overload Indicator

Page 20 of the Honda EM5000is user manual — OIL ALERT (RED)
Page 20 · click to enlarge
Page 20

CONTROL & FEATURES

The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the Oil Alert indicator comes on, and the Oil Alert system automatically will stop the engine (the engine switch will remain in the ON position).

The i-Monitor display will show ‘‘OIL’’ on the screen and the Oil Alert indicator illuminates.

If the engine stops or the Oil Alert indicator comes on when you turn the engine switch to START or pull the starter grip, check the engine oil level (see page ) before troubleshooting in other areas. Even when oil is added to the engine, the generator will not restart until the Oil Alert indicator is reset. To reset the Oil Alert indicator, turn the engine switch OFF, add the proper amount of oil (see page ), and then turn the engine switch back ON.

Honda EM5000is — CONTROL & FEATURES diagram (page 20)
Fig. 17

OIL ALERT (RED)

It blinks.

Oil Alert Indicator

Page 21 of the Honda EM5000is user manual — SINGLE-DIGIT SCREEN DISPLAY
Page 21 · click to enlarge
Page 21

CONTROL & FEATURES

TM

The i-Monitor is a user interface that allows the operator to view (when the generator is running) total operating time in hours, generator output, engine RPM, battery voltage, and error messages. The different display modes are selected by pressing the i-Monitor button.

During start up, the i-Monitor display and all three indicators will simultaneously blink once. The condition of the i-Monitor display and all three indicators can be checked with the aid of an observer. Once the generator is running, the Output indicator (green) and the i-Monitor display will remain lit.

If the key is left in the ON position for over 30 seconds without starting the engine, the display will start to flash.

The i-Monitor display is divided into two screens. The single-digit screen displays the i-Monitor mode, which is represented by a number 1 through 4. The four-digit screen displays the four mode values or any activated error messages.

i-Monitor Display Mode 1 Total Operating Hours

This mode displays the total operating hours of the generator. When the generator is running, the total operating time accumulates. If the total operating time is less than one hour, the numeric display will be ‘‘0.’’ When the operating time is one hour or greater, the display will be ‘‘1’’ or ‘‘2’’ and so on. Base the generator’s maintenance schedule on the accumulated time displayed.

SINGLE-DIGIT SCREEN DISPLAY

FOUR-DIGIT SCREEN DISPLAY

Show 6 more labels / short text on this page
i-Monitor · i-Monitor at Startup · Display Backlight Flashes · i-Monitor Display · - · i-MONITOR BUTTON
Page 22 of the Honda EM5000is user manual — CONTROL & FEATURES
Page 22 · click to enlarge
Page 22

CONTROL & FEATURES

i-Monitor Display Mode 2 Power Output

This mode displays an approximate generator output on the display screen. The output is expressed in VA (volt-amperes). The output value is not an exact measurement and should be regarded as a reference only. Power output will not display until a load is connected to the generator.

i-Monitor Display Mode 3 Engine RPM

When the i-Monitor is in this mode, the engine’s speed, expressed in revolutions-per-minute (RPM), is displayed.

i-Monitor Display Mode 4 Battery Voltage

This mode displays the battery condition, expressed in Volts DC.

- · - · -

Page 23 of the Honda EM5000is user manual — OVERLOAD INDICATOR LIGHT
Page 23 · click to enlarge
Page 23

CONTROL & FEATURES

i-Monitor Low Battery Message

If the engine switch is turned to the START position and ‘‘batt’’ is shown on the i-Monitor display, the battery voltage is too low to operate the engine’s electric starter. Use the recoil starter to start the generator. Have the battery recharged and checked (see page ). 58

i-Monitor System Error Messages

If the generator has a system malfunction, it will show an error message on the i-Monitor display. During remote control operation, an E-01 error message may display if the starter button is pressed for more than 10 seconds. With an E-01 error message, the engine will stay running and the electrical output may stay constant. Normal remote control operation will be restored after the E-01 error message clears automatically. If the E-01 error message does not clear automatically or if any other error message displays, contact an authorized Honda generator dealer.

OVERLOAD INDICATOR LIGHT

Honda EM5000is — OVERLOAD INDICATOR LIGHT diagram (page 23)
Fig. 18
ERROR MESSAGE (ExampleE-01)
Page 24 of the Honda EM5000is user manual — FULL
Page 24 · click to enlarge
Page 24

CONTROL & FEATURES

The fuel gauge is a mechanical device that measures the fuel level in the tank. The red indicator in the window will reference the level in relation to full or empty. To provide increased operating time, start with a full tank before beginning operation. Check the fuel level with the generator on a level surface. Always refuel with the engine OFF and cool.

FULL

FUEL GAUGE

EMPTY

FUEL TANK CAP

Fuel Gauge

Page 25 of the Honda EM5000is user manual — ARE YOU READY TO GET STARTED?
Page 25 · click to enlarge
Page 25

BEFORE OPERATION

ARE YOU READY TO GET STARTED?

Your safety is your responsibility. A little time spent in preparation will significantly reduce your risk of injury.

Read and understand this manual. Know what the controls do and how to operate them.

Familiarize yourself with the generator and its operation before you begin using it. Know how to quickly shut off the generator in case of an emergency.

If the generator is being used to power appliances, be sure that they do not exceed the generator’s load rating (see page ). 35

Knowledge

Page 26 of the Honda EM5000is user manual — IS YOUR GENERATOR READY TO GO?
Page 26 · click to enlarge
Page 26

BEFORE OPERATION

IS YOUR GENERATOR READY TO GO?

For your safety, and to maximize the service life of your equipment, it is very important to take a few moments before you operate the generator to check its condition. Be sure to take care of any problem you find, or have your servicing dealer correct it, before you operate the generator.

Improperly maintaining this generator, or failing to correct a problem before operation, could cause a malfunction in which you could be seriously injured.

Always perform a pre-operation inspection before each operation, and correct any problem.

To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from building walls and other equipment during operation. Do not place flammable objects close to the engine.

Before beginning your pre-operation checks, be sure the generator is on a level surface and the engine switch is in the OFF position.

Operating this generator less than 3 feet (1 meter) from a building or other obstruction can cause overheating and damage the generator. For proper cooling, allow at least 3 feet (1 meter) of empty space above and around the generator.

Page 27 of the Honda EM5000is user manual — MAINTENANCE COVER
Page 27 · click to enlarge
Page 27

BEFORE OPERATION

Check the oil level (see page ). A low oil level will cause the Oil Alert system to shut down the engine.

Check the air filter (see page ). A dirty air filter will restrict air flow to the carburetor, reducing engine and generator performance.

Check the fuel level (see page ). Starting with a full tank will help to eliminate or reduce operating interruptions for refueling.

Never operate the generator without the maintenance cover in place, as poor engine and generator performance will result.

Honda EM5000is — BEFORE OPERATION diagram (page 27)
Fig. 19

MAINTENANCE COVER

Check the Engine · Maintenance Cover

Page 28 of the Honda EM5000is user manual — SAFE OPERATING PRECAUTIONS
Page 28 · click to enlarge
Page 28

OPERATION

SAFE OPERATING PRECAUTIONS

Before operating the generator for the first time, please review the GENERATOR SAFETY (see page ) section and the chapter titled BEFORE OPERATION (see page ). 6 23

For your safety, do not operate the generator in an enclosed area such as a garage. Your generator’s exhaust contains poisonous carbon monoxide gas that can collect rapidly in an enclosed area and cause illness or death.

Exhaust contains poisonous carbon monoxide gas that can build up to dangerous levels in closed areas. Breathing carbon monoxide can cause unconsciousness or death.

Never run the generator in a closed, or even partly closed area where people may be present.

Before connecting an AC appliance or power cord to the generator:

Use grounded 3-prong extension cords, tools, and appliances, or double-insulated tools and appliances.

Inspect cords and plugs, and replace if damaged.

Make sure that the appliance is in good working order. Faulty appliances or power cords can create a potential for electric shock.

Make sure the electrical rating of the tool or appliance does not exceed that of the generator. Never exceed the maximum power rating of the generator. Power levels between rated and maximum may be used for no more than 30 minutes.

Operate the generator at least 3 feet (1 meter) away from buildings and other equipment.

Do not operate the generator in an enclosed structure.

Page 29 of the Honda EM5000is user manual — FUEL VALVE LEVER
Page 29 · click to enlarge
Page 29

OPERATION

FREQUENCY OF USE

If your generator will be used on an infrequent or intermittent basis, (more than 4 weeks before next use), please refer to the Battery Service section of the SERVICING YOUR GENERATOR (page ) and the Fuel section of the STORAGE chapter (page ) for additional information regarding battery and fuel deterioration.

STARTING THE ENGINE

Refer to SAFE OPERATING PRECAUTIONS on page and perform the IS YOUR GENERATOR READY TO GO checks (see page ).

Refer to AC Operation (see page ) for connecting loads to the generator.

Make sure that all appliances connected to the generator are turned off. The generator may be hard to start if a load is connected.

Honda EM5000is — STARTING THE ENGINE diagram (page 29)
Fig. 20

Set the Voltage Selector Switch to match the voltage requirements for the application.

120 V/ 240 V

120 V ONLY

Turn the fuel valve lever to the ON position.

FUEL VALVE LEVER

Honda EM5000is — FUEL VALVE LEVER diagram (page 29)
Fig. 21
Page 30 of the Honda EM5000is user manual — ENGINE SWITCH
Page 30 · click to enlarge
Page 30

OPERATION

Make sure the Eco-Throttle switch is in the OFF position, or more time will be required for warm-up. If you wish to use the Eco-Throttle system, turn the Eco-Throttle switch to the ON position after the engine has warmed up for 2 or 3 minutes.

ECO-THROTTLE SWITCH

Honda EM5000is — ECO-THROTTLE SWITCH diagram (page 30)
Fig. 22

Start the engine.

Using the electric starter:

Honda EM5000is — ECO-THROTTLE SWITCH diagram (page 30)
Fig. 23

Turn the engine switch to the START position, and hold it there until the engine starts. When the engine starts, release the key, allowing the switch to return to the ON position.

If the engine fails to start within 5 seconds, release the key, and wait at least 10 seconds before operating the starter again.

ENGINE SWITCH

Using the electric starter for more than 5 seconds at a time will overheat the starter motor and can damage it.

Do not leave the engine switch in the ON position when the generator is not operating as the battery will be drained. Turn the engine switch to the OFF position when not in use.

Page 31 of the Honda EM5000is user manual — OFF
Page 31 · click to enlarge
Page 31

OPERATION

Using the recoil starter:

a.

Turn the engine switch to the ON position.

Honda EM5000is — OPERATION diagram (page 31)
Fig. 24

ENGINE SWITCH

b.

Pull the starter grip lightly until you feel resistance; then pull briskly in the direction of the arrow as shown.

STARTER GRIP

Honda EM5000is — STARTER GRIP diagram (page 31)
Fig. 25

Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter.

Do not let the starter rope rub against the generator body, or the rope will wear out prematurely.

ECO-THROTTLE SWITCH

Honda EM5000is — ECO-THROTTLE SWITCH diagram (page 31)
Fig. 26

If you wish to use the Eco-Throttle system, turn the Eco-Throttle switch to the ON position after the engine has warmed up for 2 or 3 minutes.

OFF

Page 32 of the Honda EM5000is user manual — PILOT LAMP
Page 32 · click to enlarge
Page 32

OPERATION

Starting the engine with remote control (optional part)

Determine the voltage requirements and adjust the voltage selector switch, as needed.

Turn the fuel valve to the ON position.

Turn the engine switch to the REMOTE (far left) position.

Honda EM5000is — OPERATION diagram (page 32)
Fig. 27

REMOTE

FUEL VALVE

ENGINE SWITCH

Press and hold the START button on the remote control until the PILOT lamp illuminates. The START button will automatically be disabled after the engine starts.

If the engine fails to start within 5 seconds, release the button, and wait at least 10 seconds before operating the starter again.

Using the electric starter for more than 5 seconds at a time will overheat the starter motor and can damage it.

Honda EM5000is — REMOTE diagram (page 32)
Fig. 28

PILOT LAMP

START BUTTON

Page 33 of the Honda EM5000is user manual — OFF
Page 33 · click to enlarge
Page 33

OPERATION

STOPPING THE ENGINE

To stop the engine in an emergency, simply turn the engine switch to the OFF position. Under normal conditions, use the following procedure.

Unplug all appliances from all generator AC receptacles.

Turn the engine switch to the OFF position.

ON

OFF

ENGINE SWITCH

Turn the fuel valve lever to the OFF position.

Honda EM5000is — ON diagram (page 33)
Fig. 29

OFF

FUEL VALVE LEVER

Page 34 of the Honda EM5000is user manual — REMOTE
Page 34 · click to enlarge
Page 34

OPERATION

Stopping the engine with remote control (optional part)

Press the OFF button. 1.

Honda EM5000is — OPERATION diagram (page 34)
Fig. 30

OFF BUTTON

Turn the engine switch to the OFF position. Turn the fuel valve lever to the OFF position.

Honda EM5000is — OFF BUTTON diagram (page 34)
Fig. 31

REMOTE

FUEL VALVE LEVER

ENGINE SWITCH

Page 35 of the Honda EM5000is user manual — OVERLOAD INDICATOR (RED)
Page 35 · click to enlarge
Page 35

OPERATION

AC OPERATION

If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is in the appliance or the rated load capacity of the generator has been exceeded.

Substantial overloading that continuously lights the red overload indicator may damage the generator. Marginal overloading that temporarily lights the red overload indicator may shorten the service life of the generator.

Turn the voltage selector switch to either position. With the voltage selector switch in the ‘‘120 V/240 V’’ position, you can use the 120 V and 120 V/240 V receptacles simultaneously. If you are NOT using the 120 V/240 V receptacle, then select the ‘‘120 V ONLY’’ position.

Honda EM5000is — AC OPERATION diagram (page 35)
Fig. 32

120 V/240 V

120 V ONLY

Start the engine and make sure the green output indicator comes on (see pages ).

OUTPUT INDICATOR (GREEN)

Honda EM5000is — OUTPUT INDICATOR (GREEN) diagram (page 35)
Fig. 33

OVERLOAD INDICATOR (RED)

-

Page 36 of the Honda EM5000is user manual — OPERATION
Page 36 · click to enlarge
Page 36

OPERATION

Plug in the appliance.

Honda EM5000is — OPERATION diagram (page 36)
Fig. 34

PLUG Most motorized appliances require more than their rated wattage for startup.

If the generator is overloaded, or if there is a short circuit in a connected appliance, or if the inverter is overheated, the red overload indicator will come ON. The red overload indicator will stay ON and, after about five seconds, current to the connected appliance(s) will shut off, and the green output indicator will go OFF. Stop the engine and investigate the problem.

Determine if the cause is a short circuit in a connected appliance, an overload, or an overheated inverter. Correct the problem and restart the generator.

Before connecting an appliance to the generator, make sure that it is in good order and that its electrical rating does not exceed that of the generator. Then start the generator and connect the appliance power cord.

When an electric motor is started, the red overload indicator may come on. This is normal if the red overload indicator goes off after about five seconds. If the red overload indicator stays on, consult an authorized Honda generator dealer.

Page 37 of the Honda EM5000is user manual — 4,500 VA
Page 37 · click to enlarge
Page 37

OPERATION

AC Applications Before connecting an appliance or power cord to the generator:

Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical shock.

If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is the appliance or the rated load capacity of the generator has been exceeded.

Make sure that the electrical rating of the tool or appliance does not exceed that of the generator. Never exceed the maximum power rating of the generator. Power levels between rated and maximum may be used for no more than 30 minutes.

Substantial overloading will open the circuit protector. Exceeding the time limit for maximum power operation or slightly overloading the generator may not switch the circuit protector OFF, but will shorten the service life of the generator.

Limit operation requiring maximum power to 30 minutes. Maximum power is:

5,000 VA

For continuous operation (longer than 30 minutes), do not exceed the rated power. Rated power is:

4,500 VA

The total power requirements (VA) of all appliances connected must be considered. Appliance and power tool manufacturers usually list rating information near the model number or serial number.

Page 38 of the Honda EM5000is user manual — POWER CIRCUIT 1
Page 38 · click to enlarge
Page 38

OPERATION

The control panel, shown below, has a voltage selector switch and four receptacles. Receptacle 4, the 240-volt receptacle, has two powered terminals, 4A and 4B.

Honda EM5000is — OPERATION diagram (page 38)
Fig. 35

RECEPTACLE 1

TERMINAL 4A

TERMINAL 4B

VOLTAGE SELECTOR SWITCH

This generator is equipped with two power generating circuits. When the voltage selector switch is in the 120 V/240 V position, each of the two power producing circuits supplies power to specific receptacles. When the voltage selector switch is in the 120 V ONLY position, the power producing circuits operate in parallel, sharing the total load connected to terminal 4A and receptacles 1, 2, and 3.

120 V/240 V 120 V ONLY

Honda EM5000is — 120 V/240 V 120 V ONLY diagram (page 38)
Fig. 36

POWER CIRCUIT 1

Show 4 more labels / short text on this page
AC Receptacle Selection · # · # · Power Producing Circuits
Page 39 of the Honda EM5000is user manual — 120 V/240 V
Page 39 · click to enlarge
Page 39

OPERATION

Disconnect or turn OFF all appliances or tools connected to the generator before changing the voltage selector switch position. The generator may be damaged if the switch position is changed with loads connected and operating.

The power available to each receptacle depends on the position of the voltage selector switch.

Switch Position Receptacle Available Power

120 V ONLY

1 2 3 4A 4B 1 2 3 4A-4B

30 A at 120 V 20 A at 120 V 20 A at 120 V 30 A at 120 V None 18.8 A at 120 V 18.8 A at 120 V 18.8 A at 120 V 18.8 A at 240 V

120 V/240 V

120 V ONLY Position

When the voltage selector switch is in the 120 V ONLY position, you do not need to spread the load over the receptacles. You must, however, make sure the load on any receptacle does not exceed its available power shown in the preceding table and the total load does not exceed 37.5 amps.

120 V/240 V Position

When the voltage selector switch is in the 120 V/240 V position, you must balance the load. Divide the load between the two sets of receptacles shown below. Balancing is necessary because each set of receptacles is powered by only one power producing circuit that can produce a maximum of 18.8 amps.

1 3 4B 2 4A 18.8 A 18.8 A 1 2

Show 7 more labels / short text on this page
Voltage Selector Switch · Set of Receptacles · Total Current · Power Producing · Available · Circuit · + + +
Page 40 of the Honda EM5000is user manual — ECO-THROTTLE SWITCH
Page 40 · click to enlarge
Page 40

OPERATION

ECO-THROTTLE SYSTEM

With the switch in the ON position, engine speed is automatically lowered when loads are reduced, turned off, or disconnected. When appliances are turned on or reconnected, the engine returns to the proper speed to power the electrical load. In the OFF position, the Eco-Throttle system does not operate.

Appliances with large start-up power demands may not allow the engine to reach normal operating rpm when they are connected to the generator. Turn the Eco-Throttle switch to the OFF position and connect the appliance to the generator. If the engine still will not reach normal operating speed, check that the appliance does not exceed the rated load capacity of the generator.

If high electrical loads are connected simultaneously, turn the Eco-Throttle switch to the OFF position to reduce voltage changes.

The Eco-Throttle system is not effective for use with appliances or tools that require only momentary power. If the tool or appliance will be turned ON and OFF quickly, the Eco-Throttle switch should be in the OFF position.

ECO-THROTTLE SWITCH

ON

OFF

OFF ON

Page 41 of the Honda EM5000is user manual — STANDBY POWER
Page 41 · click to enlarge
Page 41

OPERATION

STANDBY POWER

Connections to a Building’s Electrical System

Your generator can supply power to a building’s electrical system. If the generator will be used as an alternative to utility company power, an isolation switch must be installed to disconnect the utility lines from the building when the generator is connected. Installation must be performed by a qualified electrician and must comply with all applicable laws and electrical codes.

Improper connections to a building’s electrical system can allow current from the generator to backfeed into the utility lines.

Such backfeed may electrocute utility company workers or others who contact the lines during a power outage, and the generator may explode, burn, or cause fires when utility power is restored.

Consult the utility company or a qualified electrician prior to making any power connections.

In some areas, generators are required by law to be registered with local utility companies. Check local regulations for proper registration and use procedures.

Honda portable generators have a system ground that connects the generator frame components to the ground terminals in the AC output receptacles. The system ground is not connected to the AC neutral wire. If the generator is tested with a receptacle tester, it will not show the same ground circuit condition as for a home receptacle.

System Ground

Page 42 of the Honda EM5000is user manual — OPERATION
Page 42 · click to enlarge
Page 42

OPERATION

There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction.

In some areas, generators are required to be registered with local utility companies.

If the generator is used at a construction site, there may be additional regulations that must be observed.

Special Requirements

Page 43 of the Honda EM5000is user manual — THE IMPORTANCE OF MAINTENANCE
Page 43 · click to enlarge
Page 43

SERVICING YOUR GENERATOR

THE IMPORTANCE OF MAINTENANCE

Good maintenance is essential for safe, economical, and trouble free operation. It will also help reduce air pollution.

To help you properly care for your generator, the following pages include a maintenance schedule, routine inspection procedures, and simple maintenance procedures using basic hand tools. Other service tasks that are more difficult or require special tools are best handled by professionals and are normally performed by a Honda technician or other qualified mechanic.

The maintenance schedule applies to normal operating conditions. If you operate your generator under unusual conditions, such as sustained high-load or high-temperature operation, or use it in dusty conditions, consult your servicing dealer for recommendations applicable to your individual needs and use.

Improper maintenance, or failure to correct a problem before operation, can cause a malfunction in which you can be seriously hurt or killed.

Always follow the inspection and maintenance recommendations and schedules in this owner’s manual.

Remember that your servicing dealer knows your generator best and is fully equipped to maintain and repair it.

To ensure the best quality and reliability, use only new, Honda Genuine parts or their equivalents for repair and replacement.

Maintenance, replacement, or repair of the emission control devices and systems may be performed by any engine repair establishment or individual, using parts that are ‘‘certified’’ to EPA standards.

Page 44 of the Honda EM5000is user manual — MAINTENANCE SAFETY
Page 44 · click to enlarge
Page 44

SERVICING YOUR GENERATOR

MAINTENANCE SAFETY

Some of the most important safety precautions follow. However, we cannot warn you of every conceivable hazard that can arise in performing maintenance. Only you can decide whether or not you should perform a given task.

Failure to properly follow maintenance instructions and precautions can cause you to be seriously hurt or killed.

Always follow the procedures and precautions in the owner’s manual.

Make sure the engine is off before you begin any maintenance or repairs. This will eliminate several potential hazards:

Carbon monoxide poisoning from engine exhaust.

Operate outside away from open windows or doors.

Burns from hot parts.

Let the engine and exhaust system cool before touching.

Injury from moving parts.

Do not run the engine unless instructed to do so.

Read the instructions before you begin, and make sure you have the tools and skills required.

To reduce the possibility of fire or explosion, be careful when working around gasoline. Use only a non-flammable solvent, not gasoline, to clean parts. Keep cigarettes, sparks, and flames away from all fuel-related parts.

Show 4 more labels / short text on this page
Safety Precautions · - · - · -
Page 45 of the Honda EM5000is user manual — MAINTENANCE SCHEDULE
Page 45 · click to enlarge
Page 45

SERVICING YOUR GENERATOR

MAINTENANCE SCHEDULE

REGULAR SERVICE PERIOD (3) ITEM Each

use Perform at every indicated month or operating hour interval, whichever comes first. Engine oil

or 20 hrs.

or 300 hrs.

or 50 hrs.

or 100 hrs.

Check level Change Check Clean Check Check Check Clean Check-adjust Replace Clean Check-adjust Clean

46 47 49 50

Canister Purge tube Charge tube Sediment cup Spark plug

Every 2 years Every 2 years Every 2 years

51 52 52 54

Spark arrester Valve clearance Combustion chamber Fuel tank and filter Fuel tube

(2) After every 1,000 hrs. (2)

Every 2 years (Replace if necessary) (2)

Service more frequently when used in dusty areas. These items should be serviced by your Honda servicing dealer, unless you have the proper tools and are mechanically proficient. Refer to the Honda shop manual for service procedures. For commercial use, log hours of operation to determine proper maintenance intervals.

Failure to follow this maintenance schedule could result in non-warrantable failures.

Show 14 more labels / short text on this page
First month · Every · Every · Every · 3 months · 6 months · year · Page · Air cleaner · (1) · Clean Check · (2) · (1) (2) · (3)
Page 46 of the Honda EM5000is user manual — REFUELING
Page 46 · click to enlarge
Page 46

SERVICING YOUR GENERATOR

REFUELING

With the engine stopped, check the fuel level gauge. Refill the fuel tank if the fuel level is low.

Gasoline is highly flammable and explosive.

You can be burned or seriously injured when handling fuel.

Stop the engine and keep heat, sparks, and flame away. Handle fuel only outdoors. Wipe up spills immediately.

Fuel can damage paint and plastic. Be careful not to spill fuel when filling your fuel tank. Damage caused by spilled fuel is not covered under warranty.

Refuel in a well-ventilated area before starting the engine. If the engine has been running, allow it to cool. Refuel carefully to avoid spilling fuel.

Do not fill the fuel tank above the upper limit mark.

Never refuel the engine inside a building where gasoline fumes may reach flames or sparks. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power tools, etc. Spilled fuel is not only a fire hazard, it causes environmental damage. Wipe up spills immediately.

Page 47 of the Honda EM5000is user manual — FUEL RECOMMENDATIONS
Page 47 · click to enlarge
Page 47

SERVICING YOUR GENERATOR

FULL

FUEL GAUGE

EMPTY

UPPER LIMIT MARK

TETHER FUEL TANK CAP

After refueling, reinstall the fuel tank cap securely.

FUEL RECOMMENDATIONS

This engine is certified to operate on regular unleaded gasoline with a pump octane rating of 86 or higher.

Never use stale or contaminated gasoline or an oil/gasoline mixture. Avoid getting dirt or water in the fuel tank.

You may use regular unleaded gasoline containing no more than 10% ethanol (E10) or 5% methanol by volume. In addition, methanol must contain cosolvents and corrosion inhibitors.

Use of fuels with content of ethanol or methanol greater than shown above may cause starting and/or performance problems. It may also damage metal, rubber, and plastic parts of the fuel system.

Engine damage or performance problems that result from using a fuel with percentages of ethanol or methanol greater than shown above are not covered under warranty.

Page 48 of the Honda EM5000is user manual — UPPER LIMIT
Page 48 · click to enlarge
Page 48

SERVICING YOUR GENERATOR

ENGINE OIL LEVEL CHECK

Check the engine oil level with the generator on a level surface and the engine stopped.

Remove the oil filler cap/dipstick and wipe it clean.

Insert and remove the dipstick without screwing it into the filler neck. Check the oil level shown on the dipstick.

If the oil level is low, fill with the recommended oil to the top of the oil filler neck (outer edge of the oil filler hole) (see page ).

Screw in the oil filler cap/dipstick securely.

DIPSTICK

Honda EM5000is — DIPSTICK diagram (page 48)
Fig. 37
Honda EM5000is — DIPSTICK diagram (page 48)
Fig. 38

UPPER LIMIT

OIL FILLER CAP

The Oil Alert system will automatically stop the engine before the oil level falls below safe limits. However, to avoid the inconvenience of an unexpected shutdown, check the oil level regularly.

Page 49 of the Honda EM5000is user manual — UPPER LIMIT
Page 49 · click to enlarge
Page 49

SERVICING YOUR GENERATOR

ENGINE OIL CHANGE

Drain the oil while the engine is warm to assure rapid and complete draining.

Place a suitable container below the engine to catch the used oil, and then remove the oil filler cap/dipstick, drain plug, and sealing washer.

Allow the used oil to drain completely, and then reinstall the drain plug and a new sealing washer. Tighten the plug securely.

Improper disposal of engine oil can be harmful to the environment. If you change your own oil, please dispose of the used oil properly. Put it in a sealed container, and take it to a recycling center. Do not discard it in a trash bin, dump it on the ground, or pour it down the drain.

With the generator in a level position, fill with the recommended oil to the outer edge of the oil filler hole (see page ).

Screw in the oil filler cap/dipstick securely.

Wash your hands with soap and water after handling used oil.

Honda EM5000is — ENGINE OIL CHANGE diagram (page 49)
Fig. 39
Honda EM5000is — ENGINE OIL CHANGE diagram (page 49)
Fig. 40

UPPER LIMIT

SEALING WASHER

OIL FILLER CAP/ DIPSTICK

OIL FILLER CAP/DIPSTICK

Page 50 of the Honda EM5000is user manual — AMBIENT TEMPERATURE
Page 50 · click to enlarge
Page 50

SERVICING YOUR GENERATOR

ENGINE OIL RECOMMENDATIONS

Oil is a major factor affecting performance and service life. Use 4-stroke automotive detergent oil.

SAE 10W 30 is recommended for general use. Other viscosities shown in the chart may be used when the average temperature in your area is within the recommended range.

AMBIENT TEMPERATURE

The SAE oil viscosity and service category are in the API label on the oil container. Honda recommends that you use API service category SJ or later (or equivalent) oil.

-

Page 51 of the Honda EM5000is user manual — COVER SCREW
Page 51 · click to enlarge
Page 51

SERVICING YOUR GENERATOR

AIR CLEANER SERVICE

Loosen the cover screws and remove the air cleaner cover.

Honda EM5000is — AIR CLEANER SERVICE diagram (page 51)
Fig. 41

COVER SCREW

Remove the foam air filter from the air cleaner housing.

Check the foam air filter to be sure it is clean and in good condition.

If the foam air filter is dirty, clean it as described on page . Replace the foam air filter if it is damaged.

Reinstall the foam air filter in the air cleaner housing.

Reinstall the air cleaner cover.

Operating the engine without an air filter or with a damaged air filter will allow dirt to enter the engine, causing rapid engine wear. This type of damage is not covered by the Distributor’s Limited Warranty.

Page 52 of the Honda EM5000is user manual — DRY
Page 52 · click to enlarge
Page 52

SERVICING YOUR GENERATOR

FOAM AIR FILTER CLEANING

A dirty foam air filter will restrict air flow to the carburetor, reducing engine performance. If you operate the generator in very dusty areas, clean the foam air filter more frequently than specified in the Maintenance Schedule (see page ).

FOAM AIR FILTER Clean the foam air filter in warm soapy water, rinse, and allow to dry thoroughly, or clean in non- flammable solvent and allow to dry.

Dip the foam air filter in clean engine oil, and then squeeze out all excess oil. The engine will smoke when started if too much oil is left in the filter.

(Do not twist.) (Do not twist.)

DRY

Wipe dirt from the air cleaner housing and cover using a moist rag. Be careful to prevent dirt from entering the air duct that leads to the carburetor.

Soak Oil · Squeeze Squeeze

Page 53 of the Honda EM5000is user manual — SEDIMENT CUP
Page 53 · click to enlarge
Page 53

SERVICING YOUR GENERATOR

SEDIMENT CUP CLEANING

Turn the fuel valve lever to the OFF position and remove the key.

Honda EM5000is — SEDIMENT CUP CLEANING diagram (page 53)
Fig. 42

KEY

Remove the sediment cup by turning it counterclockwise.

Honda EM5000is — KEY diagram (page 53)
Fig. 43

You can be burned or seriously injured when handling fuel.

Stop the engine and keep heat, sparks, and flame away. Handle fuel only outdoors. Wipe up spills immediately.

Wash the sediment cup in non-flammable solvent, and dry it thoroughly.

Reinstall the new O-ring and sediment cup.

Honda EM5000is — KEY diagram (page 53)
Fig. 44

SEDIMENT CUP

Turn the fuel valve to the ON position and check for leaks.

O-RING (replace)

Page 54 of the Honda EM5000is user manual — SPARK PLUG WRENCH
Page 54 · click to enlarge
Page 54

SERVICING YOUR GENERATOR

SPARK PLUG SERVICE

Recommended spark plugs:

BPR5ES (NGK) W16EPR-U (DENSO)

An incorrect spark plugs can cause engine damage.

If the engine is hot, allow it to cool before servicing the spark plug.

Loosen the cover screw and remove the spark plug inspection cover. 1.

SPARK PLUG INSPECTION COVER

COVER SCREW

Disconnect the spark plug cap, and remove any dirt from around the spark plug area.

Remove the spark plug with a 13/16-inch spark plug wrench (commercially available).

SPARK PLUG WRENCH

SPARK PLUG CAP

Page 55 of the Honda EM5000is user manual — SEALING WASHER
Page 55 · click to enlarge
Page 55

SERVICING YOUR GENERATOR

SIDE ELECTRODE Inspect the spark plug. Replace it if the electrodes are worn or if the insulator is cracked, chipped, or fouled.

0.028 0.031 in (0.7 0.8 mm)

SEALING WASHER

Measure the spark plug electrode gap with a wire-type feeler gauge. Correct the gap, if necessary, by carefully bending the side electrode.

The gap should be:

0.028 0.031 in (0.7 0.8 mm)

Make sure that the spark plug sealing washer is in good condition, and thread the spark plug in by hand to prevent cross-threading.

After the spark plug seats, tighten with a 13/16-inch spark plug wrench to compress the washer.

If reinstalling a used spark plug, tighten 1/8 1/4 turn after the spark plug seats. If installing a new spark plug, tighten 1/2 turn after the spark plug seats.

A loose spark plug can overheat and damage the engine. Overtightening the spark plug can damage the threads in the cylinder head.

Attach the spark plug cap.

Reinstall the spark plug inspection cover and tighten the cover screw.

- - · - - · -

Page 56 of the Honda EM5000is user manual — SPARK ARRESTER SERVICE
Page 56 · click to enlarge
Page 56

SERVICING YOUR GENERATOR

SPARK ARRESTER SERVICE

The spark arrester must be serviced every 100 hours to keep it functioning as designed.

If the engine has been running, the muffler will be very hot. Allow the muffler to cool before servicing the spark arrester.

Remove the two 8 mm flange bolts, and remove the rear bar.

Remove the six 6 mm flange nuts, and remove the muffler protector.

8 mm FLANGE BOLT (2)

Honda EM5000is — SPARK ARRESTER SERVICE diagram (page 56)
Fig. 45
Page 57 of the Honda EM5000is user manual — TORQUE:
Page 57 · click to enlarge
Page 57

SERVICING YOUR GENERATOR

Remove the three 6 mm flange bolts, and remove the exhaust tail pipe and the spark arrester.

Honda EM5000is — SERVICING YOUR GENERATOR diagram (page 57)
Fig. 46

EXHAUST TAIL PIPE

SPARK ARRESTER

6 mm FLANGE BOLT

Use a brush to remove carbon deposits from the spark arrester screen.

Be careful to avoid damaging the screen.

The spark arrester must be free of breaks and tears. Replace the spark arrester if it is damaged.

Honda EM5000is — EXHAUST TAIL PIPE diagram (page 57)
Fig. 47

Install the spark arrester and the exhaust tail pipe in the reverse order of removal.

TORQUE:

8 lbf·ft (11 N·m , 1.1 kgf·m)

Install the muffler protector and the rear pipe in the reverse order of removal.

TORQUE:

6.3 lbf·ft (8.5 N·m , 0.87 kgf·m)

Page 58 of the Honda EM5000is user manual — BATTERY SERVICE
Page 58 · click to enlarge
Page 58

SERVICING YOUR GENERATOR

BATTERY SERVICE

Your generator’s engine charging system charges the battery while the engine is running. However, if the generator is only used periodically, the battery must be charged monthly to maintain the battery service life.

The battery contains sulfuric acid (electrolyte), which is highly corrosive and poisonous. Getting electrolyte in your eyes or on your skin can cause serious burns.

Wear protective clothing and eye protection when working near the battery. KEEP CHILDREN AWAY FROM THE BATTERY.

Flush with water from a cup or other container for at least fifteen minutes. (Water under pressure can damage the eye.) Immediately call 911 (USA only) or a physician.

Remove contaminated clothing. Flush the skin with large quantities of water. Call a physician immediately.

Drink water or milk. Call your local Poison Control Center (USA only) or a physician immediately.

Show 7 more labels / short text on this page
Emergency Procedures · Eyes · - · Skin · - · Swallowing · -
Page 59 of the Honda EM5000is user manual — BATTERY STRAP
Page 59 · click to enlarge
Page 59

SERVICING YOUR GENERATOR

WARNING:

Battery posts, terminals, and related accessories contain lead and lead compounds.

Wash hands after handling.

Lift the handle upward. The lock levers will lock and secure the handle into place.

Loosen the cover screw and remove the battery maintenance cover.

Honda EM5000is — WARNING: diagram (page 59)
Fig. 48

COVER SCREW

MAINTENANCE COVER

Remove the negative ( ) cable from the battery first, and then remove the positive ( ) cable from the battery.

Unhook the battery strap from the bottom hook of the generator.

Honda EM5000is — COVER SCREW diagram (page 59)
Fig. 49

BATTERY STRAP

POSITIVE ( ) CABLE

NEGATIVE ( ) CABLE

Remove the battery from the battery tray.

Show 4 more labels / short text on this page
Battery Removal · - + · + · -
Page 60 of the Honda EM5000is user manual — SERVICING YOUR GENERATOR
Page 60 · click to enlarge
Page 60

SERVICING YOUR GENERATOR

The battery gives off explosive hydrogen gas during normal operation.

A spark or flame can cause the battery to explode with enough force to kill or seriously hurt you.

Wear protective clothing and a face shield, or have a skilled mechanic perform the battery maintenance.

The battery is rated at 11.2 Ah (ampere-hours). Charging current should equal 10% of the battery’s ampere-hour rating. A battery charger should be used that can be adjusted to deliver 1.1 amps.

Connect the battery charger following the manufacturer’s instructions.

Charge the battery 5 10 hours.

Clean the outside of the battery and the battery compartment with a solution of baking soda and water.

Install the battery into the generator.

Connect the battery positive ( ) cable to the battery positive ( ) terminal first, and tighten the bolt securely.

Slide the battery boot over the positive ( ) cable and terminal.

Connect the battery negative ( ) cable to the battery negative ( ) terminal, and tighten the bolt securely.

5. 6. 57

Install the battery strap. Install the maintenance cover in the reverse order of removal (see page ). Never operate the generator without the maintenance cover in place, as poor engine and generator performance will result.

Show 5 more labels / short text on this page
Battery Charging · - · Battery Installation · + + · - - +
Page 61 of the Honda EM5000is user manual — 1 A, 15 A
Page 61 · click to enlarge
Page 61

SERVICING YOUR GENERATOR

FUSE

If the fuse is blown, the starter motor won’t operate.

In the event of fuse failure, locate the cause of failure and repair it before you continue operation. If the fuse continues to fail, discontinue generator use and consult an authorized Honda generator dealer.

Turn the engine switch to the OFF position and remove the key before checking or replacing the fuse.

Honda EM5000is — FUSE diagram (page 61)
Fig. 50

Loosen the cover screw and remove the battery maintenance cover.

COVER SCREW

MAINTENANCE COVER

Remove the fuse holder cover and pull the fuse out.

Replace the fuse with a fuse of the same type and rating.

Honda EM5000is — COVER SCREW diagram (page 61)
Fig. 51

Specified fuse:

1 A, 15 A

Never use a fuse with a different rating from that specified. Serious damage to the electrical system or fire may result.

Install the fuse holder cover and the maintenance cover in the reverse order of removal (see page ). Never operate the generator without the maintenance cover in place, as poor engine and generator performance will result.

Page 62 of the Honda EM5000is user manual — STORAGE PREPARATION
Page 62 · click to enlarge
Page 62

STORAGE

STORAGE PREPARATION

Proper storage preparation is essential for keeping your generator trouble-free and looking good. The following steps will help to keep rust and corrosion from impairing your generator’s function and appearance, and will make the engine easier to start when you use the generator again.

Wipe the generator with a moist cloth. After the generator has dried, touch up any damaged paint, and coat other areas that may rust with a light film of oil.

Depending on the region where you operate your equipment, fuel formulations may deteriorate and oxidize rapidly. Fuel deterioration and oxidation can occur in as little as 30 days and may cause damage to the carburetor and/or fuel system. Please check with your servicing dealer for local storage recommendations.

Gasoline will oxidize and deteriorate in storage. Old gasoline will cause hard starting, and it leaves gum deposits that clog the fuel system. If the gasoline in your generator deteriorates during storage, you may need to have the carburetor and other fuel system components serviced or replaced.

The length of time that gasoline can be left in your fuel tank and carburetor without causing functional problems will vary with such factors as gasoline blend, your storage temperatures, and whether the fuel tank is partially or completely filled. The air in a partially filled fuel tank promotes fuel deterioration. Very warm storage temperatures accelerate fuel deterioration. Fuel deterioration problems may occur within a few months, or even less if the gasoline was not fresh when you filled the fuel tank.

The does not cover fuel system damage or engine performance problems resulting from neglected storage preparation.

Cleaning · Fuel · Distributor’s Limited Warranty

Page 63 of the Honda EM5000is user manual — STORAGE
Page 63 · click to enlarge
Page 63

STORAGE

Service according to the table below:

RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING STORAGE TIME

Less than 1 month 1 to 2 months

No preparation required Fill with fresh gasoline and add gasoline stabilizer *. Fill with fresh gasoline and add gasoline stabilizer *. Drain the carburetor float bowl (page 62 ). Drain the fuel sediment cup (page 51 ). Fill with fresh gasoline and add gasoline stabilizer *. Drain the carburetor float bowl (page 62 ). Drain the fuel sediment cup (page 51 ). Remove the spark plug. Put a teaspoon of engine oil into the cylinder. Turn the engine slowly with the pull rope to distribute the oil. Reinstall the spark plug. Change the engine oil (page 47 ). After removal from storage, drain the stored gasoline into a suitable container, and fill with fresh gasoline before starting. Use gasoline stabilizers that are formulated to extend storage life. Follow the manufacturer’s instructions for use. Contact your authorized Honda generator dealer for stabilizer recommendations.

2 months to 1 year

1 year or more

*

Page 64 of the Honda EM5000is user manual — DRAIN SCREW
Page 64 · click to enlarge
Page 64

STORAGE

Draining the Fuel Tank and Carburetor

Gasoline is highly flammable and explosive.

You can be burned or seriously injured when handling fuel.

Stop the engine and keep heat, sparks, and flame away. Handle fuel only outdoors. Wipe up spills immediately.

DRAIN SCREW

Place a suitable gasoline container below the carburetor drain hose.

Loosen the carburetor drain screw and drain the gasoline from the carburetor.

After all the fuel has drained into the container, tighten the drain screw securely.

Place an approved gasoline container below the sediment cup, and use a funnel to avoid spilling fuel. Remove the sediment cup, and then move the fuel valve lever to the ON position (see page ).

Allow the fuel to drain completely, and then reinstall the sediment cup (see page ).

Page 65 of the Honda EM5000is user manual — STORAGE
Page 65 · click to enlarge
Page 65

STORAGE

Change the engine oil (see page ).

Remove the spark plug (see page ).

Pour a teaspoon (5 cc) of clean engine oil into the cylinder.

Pull the starter grip several times to distribute the oil in the cylinder.

Reinstall the spark plug.

Slowly pull the starter grip until resistance is felt. At this point, the piston is coming up on its compression stroke and both the intake and exhaust valves are closed. Storing the engine in this position will help to protect it from internal corrosion. Return the starter grip gently.

Charge the battery before storing the generator (see page ).

Engine Oil · Battery

Page 66 of the Honda EM5000is user manual — REMOVAL FROM STORAGE
Page 66 · click to enlarge
Page 66

STORAGE

STORAGE PRECAUTIONS

If your generator will be stored with gasoline in the fuel tank and carburetor, it is important to reduce the hazard of gasoline vapor ignition.

Select a well ventilated storage area away from any appliance that operates with a flame, such as a furnace, water heater, or clothes dryer.

Also avoid any area with a spark-producing electric motor, or where power tools are operated.

If possible, avoid storage areas with high humidity, because that promotes rust and corrosion.

Unless all fuel has been drained from the fuel tank, leave the fuel valve in the OFF position to reduce the possibility of leakage.

Place the generator on a level surface. Tilting can cause fuel or oil leakage.

With the engine and exhaust system cool, cover the generator to keep out dust. A hot engine and exhaust system can ignite or melt some materials.

Do not use sheet plastic as a dust cover. A nonporous cover will trap moisture around the generator, promoting rust and corrosion.

Fully charge the battery. Recharge the battery once a month (see page

).

REMOVAL FROM STORAGE

Check your generator as described in the BEFORE OPERATION chapter of this manual (see page ).

If the generator was stored for 1 year or longer, drain the fuel tank (see page ) and refuel with fresh gasoline. If you keep a container of gasoline for refueling, be sure that it contains only fresh gasoline. Gasoline oxidizes and deteriorates over time, causing hard starting.

If the cylinder was coated with oil during storage preparation, the engine may smoke briefly at startup. This is normal.

Page 67 of the Honda EM5000is user manual — TRANSPORTING
Page 67 · click to enlarge
Page 67

TRANSPORTING

If the generator has been running, allow the engine to cool for at least 15 minutes before loading the generator on the transport vehicle. A hot engine and exhaust system can burn you and can ignite some materials.

Keep the generator level when transporting to reduce the possibility of fuel leakage. Move the fuel valve to the OFF position.

When using ropes or tie-down straps to secure the generator for transportation, be sure to only use the frame bars as attachment points. Do not fasten ropes or straps to any portions of the generator body or the folding transport handle.

Page 68 of the Honda EM5000is user manual — ENGINE PROBLEMS
Page 68 · click to enlarge
Page 68

TAKING CARE OF UNEXPECTED PROBLEMS

ENGINE PROBLEMS

Engine Will Not Start

Check control positions.

Fuel valve lever OFF. Engine switch OFF.

Turn lever ON.

Turn engine switch to ON. Refuel (p. 44). Drain fuel tank and carburetor (p. 62). Refuel with fresh gasoline (p. 44).

Check fuel.

Out of fuel. Bad fuel; generator stored without treating or draining gasoline, or refueled with bad gasoline. Low oil level caused Oil Alert to stop engine.

Check engine oil level.

Add oil (p. 46). Turn engine switch to OFF and restart the engine. Gap or replace spark plug (p. 52).

Remove and inspect spark plug.

Spark plug faulty, fouled, or improperly gapped. Spark plug wet with fuel (flooded engine). Fuel filter restricted, carburetor malfunction, ignition malfunction, valves stuck, etc.

Dry and reinstall spark plug.

Take generator to an authorized Honda servicing dealer, or refer to shop manual.

Replace or repair faulty components as necessary.

Possible Cause Correction

Page 69 of the Honda EM5000is user manual — TAKING CARE OF UNEXPECTED PROBLEMS
Page 69 · click to enlarge
Page 69

TAKING CARE OF UNEXPECTED PROBLEMS

Check air filter.

Air filter restricted.

Clean or replace air filter (p. 49). Drain fuel tank and carburetor (p. 62). Refuel with fresh gasoline (p. 44).

Check fuel.

Bad fuel; generator stored without treating or draining gasoline, or refueled with bad gasoline. Fuel filter restricted, carburetor malfunction, ignition malfunction, valves stuck, etc.

Take generator to an authorized Honda servicing dealer, or refer to shop manual.

Replace or repair faulty components as necessary.

Engine Lacks Power · Possible cause Correction

Page 70 of the Honda EM5000is user manual — GENERATOR PROBLEMS
Page 70 · click to enlarge
Page 70

TAKING CARE OF UNEXPECTED PROBLEMS

GENERATOR PROBLEMS

No Power at the AC Receptacles

Check output and overload indicator.

Output indicator is OFF, and overload indicator is ON.

Check AC load. Stop and restart the engine. Check the cooling air inlet. Stop and restart the engine. Check AC load and reset circuit protector(s) (p. 14). Replace or repair power tool or appliance. Stop and restart the engine. Replace or repair faulty components as necessary.

Check circuit protectors.

Circuit protector(s) tripped.

Check the power tool or appliance at a known, good AC power source. Take generator to an authorized Honda servicing dealer, or refer to shop manual.

Faulty power tool or appliance.

Faulty generator.

Possible Cause Correction

Page 71 of the Honda EM5000is user manual — FRAME SERIAL NUMBER
Page 71 · click to enlarge
Page 71

TECHNICAL & CONSUMER INFORMATION

TECHNICAL INFORMATION

Honda EM5000is — TECHNICAL INFORMATION diagram (page 71)
Fig. 52

FRAME SERIAL NUMBER

Record the frame serial number and date purchased in the spaces below. You will need this information when ordering parts and when making technical or warranty inquiries.

Frame serial number:

Date purchased:

Serial Number Location

Page 72 of the Honda EM5000is user manual — TECHNICAL & CONSUMER INFORMATION
Page 72 · click to enlarge
Page 72

TECHNICAL & CONSUMER INFORMATION

Carburetor Modification for High Altitude Operation

At high altitude, the standard carburetor air-fuel mixture will be too rich. Performance will decrease, and fuel consumption will increase. A very rich mixture will also foul the spark plug and cause hard starting. Operation at an altitude that differs from that at which this engine was certified, for extended periods of time, may increase emissions.

High altitude performance can be improved by specific modifications to the carburetor. If you always operate your generator at altitudes above 5,000 feet (1,500 meters), have your authorized Honda servicing dealer perform this carburetor modification. This engine, when operated at high altitude with the carburetor modifications for high altitude use, will meet each emission standard throughout its useful life.

Even with carburetor modification, engine horsepower will decrease about 3.5% for each 1,000-foot (300-meter) increase in altitude. The effect of altitude on horsepower will be greater than this if no carburetor modification is made.

When the carburetor has been modified for high altitude operation, the air/fuel mixture will be too lean for low altitude use. Operation at altitudes below 5,000 feet (1,500 meters) with a modified carburetor may cause the engine to overheat and result in serious engine damage. For use at low altitudes, have your servicing dealer return the carburetor to original factory specifications.

Page 73 of the Honda EM5000is user manual — TECHNICAL & CONSUMER INFORMATION
Page 73 · click to enlarge
Page 73

TECHNICAL & CONSUMER INFORMATION

Emission Control System Information

The combustion process produces carbon monoxide, oxides of nitrogen, and hydrocarbons. Control of hydrocarbons and oxides of nitrogen is very important because, under certain conditions, they react to form photochemical smog when subjected to sunlight. Carbon monoxide does not react in the same way, but it is toxic.

Honda utilizes appropriate air/fuel ratios and other emissions control systems to reduce the emissions of carbon monoxide, oxides of nitrogen, and hydrocarbons. Additionally, Honda fuel systems utilize components and control technologies to reduce evaporative emissions.

The U.S. and California Clean Air Acts

EPA and California regulations require all manufacturers to furnish written instructions describing the operation and maintenance of emission control systems.

The following instructions and procedures must be followed in order to keep the Honda engine emissions within the emission standards.

Source of Emissions

Page 74 of the Honda EM5000is user manual — TECHNICAL & CONSUMER INFORMATION
Page 74 · click to enlarge
Page 74

TECHNICAL & CONSUMER INFORMATION

Tampering is a violation of Federal and California law.

Tampering with or altering the emission control system may increase emissions beyond the legal limit. Among those acts that constitute tampering are:

Removal or alteration of any part of intake, fuel, or exhaust systems.

Altering or defeating the governor linkage or speed-adjusting mechanism to cause the engine to operate outside its design parameters.

Tampering and Altering

Page 75 of the Honda EM5000is user manual — TECHNICAL & CONSUMER INFORMATION
Page 75 · click to enlarge
Page 75

TECHNICAL & CONSUMER INFORMATION

Problems That May Affect Emissions

If you are aware of any of the following symptoms, have your engine inspected and repaired by your authorized Honda servicing dealer.

Hard starting or stalling after starting.

Rough idle.

Misfiring or backfiring under load.

Afterburning (backfiring).

Black exhaust smoke or high fuel consumption.

The emission control systems on your Honda engine were designed, built, and certified to conform with EPA and California (models certified for sale in California) emission regulations. We recommend the use of Honda Genuine parts whenever you have maintenance done. These original-design replacement parts are manufactured to the same standards as the original parts, so you can be confident of their performance. The use of replacement parts that are not of the original design and quality may impair the effectiveness of your emission control system.

A manufacturer of an aftermarket part assumes the responsibility that the part will not adversely affect emission performance. The manufacturer or rebuilder of the part must certify that use of the part will not result in a failure of the engine to comply with emission regulations.

Follow the MAINTENANCE SCHEDULE on page . Remember that this schedule is based on the assumption that your machine will be used for its designed purpose. Sustained high-load or high- temperature operation, or use in dusty conditions, will require more frequent service.

Replacement Parts · Maintenance

Page 76 of the Honda EM5000is user manual — TECHNICAL & CONSUMER INFORMATION
Page 76 · click to enlarge
Page 76

TECHNICAL & CONSUMER INFORMATION

Air Index (Models certified for sale in California)

An Air Index Information label is applied to engines certified to an emission durability time period in accordance with the requirements of the California Air Resources Board.

The bar graph is intended to provide you, our customer, the ability to compare the emissions performance of available engines. The lower the Air Index, the less pollution.

The durability description is intended to provide you with information relating to the engine’s emission durability period. The descriptive term indicates the useful life period for the engine’s emission control system. See your Emission Control System Warranty for additional information.

Applicable to Emission Durability Period

50 hours (0 80 cc, inclusive) 125 hours (greater than 80 cc)

125 hours (0 80 cc, inclusive) 250 hours (greater than 80 cc)

300 hours (0 80 cc, inclusive) 500 hours (greater than 80 cc) 1,000 hours (225 cc and greater)

Show 6 more labels / short text on this page
Moderate Descriptive Term · - · Intermediate · - · Extended · -
Page 77 of the Honda EM5000is user manual — W16EPR-U (DENSO)
Page 77 · click to enlarge
Page 77

TECHNICAL & CONSUMER INFORMATION

Model Description code Length [Handle in up position] Width Height [Handle in up position] Dry mass [weight]

225.1 lbs (102.1 kg) 27.9 in (709 mm) 27.2 in (692 mm) 26.2 in (666 mm) 45.5 in (1,155 mm) 31.9 in (810 mm) EAJJ EM5000is

Model Engine type Displacement [Bore Stroke] Compression ratio Engine speed Cooling system Ignition system Oil capacity Fuel tank capacity Spark plug

Forced air 2,400 3,600 rpm 8.2:1 3.46 2.52 in (88.0 64.0 mm) 23.7 cu-in (389 cm ) 4-stroke, overhead valve, single cylinder GX340

BPR5ES (NGK) 4.23 US gal (16.0 L) 1.2 US qt (1.1 L) Full transistor

W16EPR-U (DENSO)

Rated voltage Rated frequency AC output Rated current

5.0 kVA 4.5 kVA 37.5/18.8 A 60 Hz 120/240 V

Rated output Maximum output

Show 16 more labels / short text on this page
Specifications · Dimensions · [ ] · [ · ] · * · * · With battery · Engine · × · [ ] · × × · - · 〈 〉 · Eco-Throttle ON · Generator
Page 78 of the Honda EM5000is user manual — ITEM MAINTENANCE
Page 78 · click to enlarge
Page 78

TECHNICAL & CONSUMER INFORMATION

ITEM MAINTENANCE

Spark plug gap Valve clearance (cold)

0.028 0.031 in (0.7 0.8 mm)

Refer to page52 See your authorized Honda dealer
EX0.20 0.02 mm IN: 0.15 0.02 mm

No other adjustments needed.

Specifications may vary according to the types, and are subject to change without notice.

Show 4 more labels / short text on this page
SPECIFICATION Tuneup Specifications · - - · ± ± · Other specifications
Page 79 of the Honda EM5000is user manual — TECHNICAL & CONSUMER INFORMATION
Page 79 · click to enlarge
Page 79

TECHNICAL & CONSUMER INFORMATION

Honda EM5000is — TECHNICAL & CONSUMER INFORMATION diagram (page 79)
Fig. 53

Wiring Diagram

Page 80 of the Honda EM5000is user manual — CONSUMER INFORMATION
Page 80 · click to enlarge
Page 80

TECHNICAL & CONSUMER INFORMATION

CONSUMER INFORMATION

This manual covers complete maintenance and overhaul procedures. It is intended to be used by a skilled technician. Available through your Honda dealer or through Helm Inc. at 1 (888) 292-5395 or visit www.hondapowerequipment.com/products/ manuals/

This manual provides complete, illustrated parts lists. Available through your Honda dealer.

Your authorized Honda power equipment dealer offers a wide selection of accessories (optional equipment) to make your generator even more useful.

Visit www.hondapowerequipment.com/products/accessories/ and click on Generators and Welders to see the entire catalog of accessories.

Show 4 more labels / short text on this page
Honda Publications · Shop Manual · Parts Catalog · Accessories Catalog
Page 81 of the Honda EM5000is user manual — TECHNICAL & CONSUMER INFORMATION
Page 81 · click to enlarge
Page 81

TECHNICAL & CONSUMER INFORMATION

To find an authorized Honda Servicing Dealer anywhere in the United States, visit our website: www.hondapowerequipment.com/ dealerlocator/ Visit our web site: www.hondapowerequipment.com/dealerlocator/

Honda Power Equipment dealership personnel are trained professionals. They should be able to answer any question you may have. If you encounter a problem that your dealer does not solve to your satisfaction, please discuss it with the dealership’s management. The Service Manager or General Manager can help. Almost all problems are solved in this way.

If you are dissatisfied with the decision made by the dealership’s management, contact the Honda Power Equipment Customer Relations Office. You can write:

American Honda Motor Co., Inc. Power Equipment Division Customer Relations Office 4900 Marconi Drive Alpharetta, Georgia 30005-8847

Or telephone(770) 497-6400 8:30 am to 7:00 pm ET

When you write or call, please give us this information:

Model and serial numbers (see page ) Name of the dealer who sold the generator to you Name and address of the dealer who services your generator Date of purchase Your name, address, and telephone number A detailed description of the problem

Dealer Locator Information · Customer Service Information

Page 82 of the Honda EM5000is user manual — SAFETY
Page 82 · click to enlarge
Page 82

ASSEMBLY

SAFETY

The Importance of Proper Assembly

Proper assembly is essential to operator safety and the reliability of the machine. Any error or oversight made by the person assembling and servicing a unit can easily result in faulty operation, damage to the machine, or injury to the operator.

Improper assembly can cause an unsafe condition that can lead to serious injury or death.

Follow the procedures and precautions in the assembly instructions carefully.

Some of the most important safety precautions are given below. However, we cannot warn you of every conceivable hazard that can arise in performing this assembly. Only you can decide whether or not you should perform a given task.

Failure to properly follow instructions and precautions can cause you to be seriously hurt or killed.

Follow the procedures and precautions in this manual carefully.

Page 83 of the Honda EM5000is user manual — ASSEMBLY
Page 83 · click to enlarge
Page 83

ASSEMBLY

Make sure you have a clear understanding of all basic shop safety practices and that you are wearing appropriate clothing and safety equipment. When performing this assembly, be especially careful of the following:

Read the instructions before you begin, and be sure you have the tools and skills required to perform the tasks safely.

Make sure the engine is off before you begin any assembly, maintenance, or repairs. This will help eliminate several potential hazards:

Carbon monoxide poisoning from engine exhaust.

Operate outside away from open windows or doors.

Burns from hot parts.

Let the engine and exhaust system cool before touching.

Injury from moving parts.

Do not run the engine unless the instruction tells you to do so. Even then, keep your hands, fingers, and clothing away. Do not run the engine when any protective guard or shield is removed.

To reduce the possibility of a fire or explosion, be careful when working around gasoline or batteries. Use only a non-flammable solvent, not gasoline, to clean parts. Keep all cigarettes, sparks, and flames away from all fuel-related parts.

Show 4 more labels / short text on this page
□ · □ · □ · □
Page 84 of the Honda EM5000is user manual — ASSEMBLY
Page 84 · click to enlarge
Page 84

ASSEMBLY

ASSEMBLY

Remove the generator and loose parts box from the carton.

Compare the loose parts with the inventory list below.

Tools Required:

12 mm wrench, 10 mm wrench or Phillips head screwdriver for battery connections, pliers (not included)

Check all loose parts against the following list. Contact your dealer if any of the loose parts shown below are not included with your generator.

Honda EM5000is — ASSEMBLY diagram (page 84)
Fig. 54

Description Wheel Axle Handle assembly Rear pipe Stand 20 mm Washer 4.0 28 mm Cotter pin

Description 12 mm Washer Spring Washer Handle holder bolt 8 45 mm Flange bolt 8 16 mm Flange bolt

Unpacking · Loose Parts

Page 85 of the Honda EM5000is user manual — TORQUE:
Page 85 · click to enlarge
Page 85

ASSEMBLY

Do not operate the generator without the wheel kit installed. The wheel kit provides an air space between the ground and the generator air intake.

If the wheel kit is not installed, it may be possible for dirt and debris to be drawn into the generator air intake, possibly causing generator damage. Always operate the generator with the wheel kit installed.

Install the two wheels on the axle using the 20 mm washers and 4.0 28 mm cotter pins. 1.

Install the axle assembly on the generator using four 8 16 mm flange bolts.

Install the two stands on the under frame using four 8 16 mm flange bolts.

TORQUE:

17 22 lbf·ft (24 29 N·m , 2.4 3.0 kgf·m)

Honda EM5000is — TORQUE: diagram (page 85)
Fig. 55

8 16 mm FLANGE BOLT (4) 4.0 28 mm COTTER PIN (2)

Show 6 more labels / short text on this page
Wheel Kit Installation · × · × · × · - - - · ×
Page 86 of the Honda EM5000is user manual — HANDLE LOCK LEVER
Page 86 · click to enlarge
Page 86

ASSEMBLY

Install the handle assembly on the generator upper frame using the 12 mm washers, spring washers and handle holder bolts.

TORQUE:

17 22 lbf·ft (24 29 N·m , 2.4 3.0 kgf·m)

HANDLE HOLDER BOLT (2)

Honda EM5000is — HANDLE HOLDER BOLT (2) diagram (page 86)
Fig. 56

HANDLE ASSEMBLY

Operation must be checked after attaching the handle.

To extend handle:

Raise the handle to the horizontal position. The handle will click into place when locked.

HANDLE LOCK LEVER

Honda EM5000is — HANDLE LOCK LEVER diagram (page 86)
Fig. 57

Handle Installation · - - -

Page 87 of the Honda EM5000is user manual — REAR BAR
Page 87 · click to enlarge
Page 87

ASSEMBLY

Install the rear bar on the generator frame using the two 8 45 mm flange bolts.

TORQUE:

17 22 lbf·ft (24 29 N·m , 2.4 3.0 kgf·m)

8 45mm FLANGE BOLT (2)

REAR BAR

Show 4 more labels / short text on this page
Rear Bar Installation · × · - - - · ×
Page 88 of the Honda EM5000is user manual — BATTERY STRAP
Page 88 · click to enlarge
Page 88

ASSEMBLY

The battery is a standard part for this generator.

WARNING:

Battery posts, terminals, and related accessories contain lead and lead compounds.

Wash hands after handling.

The battery is disconnected and the battery cables and blue coupler harness are clamped twist clipped into the battery tray for shipment.

Remove the maintenance cover (see page ). Remove the battery strap from the bottom hook, and then remove the battery.

Only remove the battery cables from the twist clip. Make sure that the 4-pin blue coupler harness is secured with the twist clip. Return the battery to its tray. Remove the protective cover from the battery positive ( ) terminal, and connect the positive ( ) cable to the battery positive ( ) terminal. Move the protective cover back over the positive ( ) terminal.

Connect the negative ( ) cable to the battery negative ( ) terminal. 5. 6.

To secure the battery, hook the battery strap onto the bottom hook of the generator.

BATTERY CABLES

4-PIN BLUE COUPLER HARNESS

Honda EM5000is — BATTERY CABLES diagram (page 88)
Fig. 58

BATTERY STRAP

BOTTOM HOOK

Show 4 more labels / short text on this page
Battery · + + + · + · - -
Page 89 of the Honda EM5000is user manual — ASSEMBLY
Page 89 · click to enlarge
Page 89

ASSEMBLY

Install the maintenance cover in the reverse order of removal (see page ). Never operate the generator without the maintenance cover in place, as poor engine and generator performance will result.

Page 90 of the Honda EM5000is user manual — FILLER CAP/ DIPSTICK
Page 90 · click to enlarge
Page 90

ASSEMBLY

The generator is shipped

Honda EM5000is — ASSEMBLY diagram (page 90)
Fig. 59

WITHOUT OIL

in the engine.

Place the generator on a level surface. Add enough of the recommended oil to bring the oil level to the top of the oil filler neck.

Use a 4-stroke motor oil that meets the requirements for API service category SJ or later (or equivalent).

AMBIENT TEMPERATURE

OIL FILLER HOLE

Honda EM5000is — AMBIENT TEMPERATURE diagram (page 90)
Fig. 60

SAE 10W-30 is recommended for general, all-temperature use. Other viscosities in the chart may be used when the temperature in your area is within the indicated range.

Do not overfill the engine with oil. If the engine is overfilled, the excess oil may get transferred to the air cleaner housing and air filter.

FILLER CAP/ DIPSTICK

UPPER LIMIT

Honda EM5000is — FILLER CAP/ DIPSTICK diagram (page 90)
Fig. 61

Refer to pages . 44 45

Engine Oil · Fuel · -

Page 91 of the Honda EM5000is user manual — GENERATOR SAFETY
Page 91 · click to enlarge
Page 91

ASSEMBLY

BEFORE OPERATION

Before using your generator, you should become familiar with information contained in the following chapters and sections:

GENERATOR SAFETY

CONTROLS & FEATURES

BEFORE OPERATION

OPERATION

STARTING THE ENGINE

STOPPING THE ENGINE

Show 6 more labels / short text on this page
(page ) · (page ) · (page ) · (page ) · (page ) · (page )
Page 92 of the Honda EM5000is user manual — KNOCKOUT
Page 92 · click to enlarge
Page 92

OPTIONAL PARTS

Remove the maintenance cover (see page ).

Remove the plug from the 6-pin connector.

6-PIN CONNECTOR

PLUG

View the back of the maintenance cover and locate the knockout near the top center of the cover. Carefully remove the knockout.

KNOCKOUT

Remote Control Kit · MAINTENANCE COVER (backside)

Page 93 of the Honda EM5000is user manual — PLUG
Page 93 · click to enlarge
Page 93

OPTIONAL PARTS

Pass the remote control cable through the supplied wire grommet and fit the grommet into the maintenance cover knockout. Plug the remote control cable into the 6-pin connector. Install the maintenance cover and tighten the cover screw.

Honda EM5000is — OPTIONAL PARTS diagram (page 93)
Fig. 62

To avoid accidentally unplugging the remote control cable, secure the cable to the generator frame with a cable tie as shown.

Honda EM5000is — OPTIONAL PARTS diagram (page 93)
Fig. 63

CABLE TIE

Honda EM5000is — CABLE TIE diagram (page 93)
Fig. 64

Never operate the generator without the maintenance cover in place, as poor engine and generator performance will result.

When the remote control is not being used, replace it with the plug on the connector.

PLUG

Page 94 of the Honda EM5000is user manual — GENERATOR SAFETY
Page 94 · click to enlarge
Page 94

OPTIONAL PARTS

Before using your generator by remote control, you should become familiar with the information contained in the following chapters and sections:

GENERATOR SAFETY

CONTROLS & FEATURES

BEFORE OPERATION

OPERATION

STARTING THE ENGINE

STOPPING THE ENGINE

Show 6 more labels / short text on this page
(page ) · (page ) · (page ) · (page ) · (page ) · (page )
Page 95 of the Honda EM5000is user manual — GENERATOR SIDE
Page 95 · click to enlarge
Page 95

OPTIONAL PARTS

Position the hanger at the generator’s balance point as shown below.

Fit the end tabs of the hanger through the bracket slots, and bolt the brackets to the hanger and tighten securely.

TORQUE:

17 22 lbf·ft (24 29 N·m , 2.4 3.0 kgf·m)

HANGER BRACKET (2)

Honda EM5000is — HANGER BRACKET (2) diagram (page 95)
Fig. 65
Honda EM5000is — HANGER BRACKET (2) diagram (page 95)
Fig. 66

GENERATOR SIDE

RIB

Hanger Kit · - - - · ×

Page 103 of the Honda EM5000is user manual — W16EPR-U BPR5ES
Page 103 · click to enlarge
Page 103

QUICK REFERENCE INFORMATION

Unleaded gasoline with a pump octane rating of 86 or higher Fuel

SAE 10W-30, API SJ or later (or equivalent), for general use (page 48 )

NGKDENSO: Electrode Gap Before each use

W16EPR-U BPR5ES

0.028 0.031 in (0.7 0.8 mm) Check engine oil level. Check air cleaner. Change engine oil. See Maintenance Schedule (page 43 )

Show 9 more labels / short text on this page
Type · Engine oil · Type · Spark Plug · Type · - - · Maintenance · First 20 hours · Subsequent
Page 104 of the Honda EM5000is user manual — 00X31Z117200
Page 104 · click to enlarge
Page 104

00X31Z117200

Ask about the Honda EM5000is

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Honda EM5000is

Be the first to ask — other owners or our team will answer.

Original document

Honda EM5000is manual PDF

104 pages·4.1 MB·Generator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…