Instructions for use Haier Split air conditioners Wall devices Monosplit-/Multisplite Stand / Ceiling devices Cassette equipment Channel devices H-MRV Inverter- Multispliter Device This user manual contains important instructions for the safe and comfortable operation of your air conditioning device. – Please read this user manual carefully before using the air conditioner.



Preliminary remarks We congratulate you on the purchase of a Haier Wand - split air conditioning unit. We are pleased that your choice has fallen on this device. You have purchased an air conditioner that has been designed and manufactured according to the latest state of technology. Please read this user manual carefully. The present user manual helps you to familiarize yourself with the device and gives important tips for a sensible use of the air conditioner. In addition, this operating manual contains instructions for the care and maintenance of the air conditioner, compliance with which is an important prerequisite for maintaining the service life, performance and cost-effectiveness of the climate control device. Installation of precautionary instructions Installation and maintenance of this air conditioner must only be carried out by qualified professionals. Improper installation, incorrect operation and maintenance of the air conditioning unit can cause damage to persons, environment and on the device itself and lead at any rate to loss of warranty claims and compensation. The precautionary instructions given in the user manual and installation manual/technical manual shall be taken into account and complied with, as well as national and international regulations applicable to the installation and operation of the air conditioner. Maintenance work Certain maintenance work on this air conditioner can be carried out by the operator himself. A description of this work is contained in the operating instructions. The work should be carried out at regular intervals. In addition, the operator of the plant is obliged to have inspection and maintenance work carried out by authorized and qualified specialists at regular intervals. All documentation relating to this air conditioner (operating manual / installation and technical handbook) must be carefully kept by the operator of the plant and delivered to maintenance/inspection personnel. Work on the air conditioner may only be carried out when the plant is at a standstill. For this purpose, the system shall be de-energised in accordance with the manufacturer’s instructions and its absence checked by an appropriate means. When put into service, the relevant instructions must be observed. Replacement and accessories The modification of the equipment is not permitted. Only original spare parts and accessories may be used. The conversion of the plant and the use of unauthorized spare parts and accessories lead to loss of all warranty claims and damages. Improper use / operational limits The prerequisite for ensuring and operating safety of the plant is its intended use as well as taking into account the operational limits of the air conditioner.






SUCTION GRID
AIR OUTLET
KOMPRESSOR (inside) 1.2. Interior units 1.2.1. Wall equipment
KOMPRESSOR (Inside)

Air outlet Infrared - receiver The air discharge direction is controlled by horizontal and vertical lamellas.
The indoor unit emits a biep sound when a signal is received by the remote control.


For removing the condensate during cooling operation
ENGINE-CONTROLLED AIR OUTLET NOZZLES
CONNECTING LINES AIR OUTLET
AIR OUTLET
SUCTION GRID
1.2.3. Floor/ceiling equipment

AIR FILTER (in the intake grille)

2. Infrared – Remote control type 1 2.1. Description of keys Below you will find a description of the buttons of infrared remote control. A detailed explanation of the functions of each button can be found further down in this guide. Notes * Heating mode is only available for models with heat pump circuit. ** AUTO - fan speed operation is not available for selection on some operating programs. *** The HEALTH function is not available on some models. For models with filter lift, the FILTER button is located at this point. The Health function is not available on these models. For models without a filter lift that do not have the Health function, the SLEEP button is located at this point. **** Depending on the model, the SLEEP button can also be located elsewhere.
With this button, turn the air conditioner on and off.
With these two buttons, you set the desired temperature.
FAN
With this button you can change the air blowing direction of the climate control unit.
With this button, select the fan speed. Low (LO) Medium (MED) High (HI) and AUTO (Automatic)**
18:88 18:88
The operating mode of the air conditioning device is set with this button. Available:
With this button, activate the ionizer. ***
AUTO, cooling mode, dehumidification mode, heating mode* and fan operation.
MOD E HEALTH
CLOCK
Key for confirming inputs when setting the time and timer programming
You need this button to set the time.
With this button, activate the night switch. ****
For the selection and programming of timer (time switch) operation.
With these two buttons, you set time and timer times.
RESET
With this button you can lock the keys of the remote control. (Not available on all models.)
With this button, you can reset the remote to factory settings.




2.4. Instructions for using the remote control When using the remote control, always point it towards the receiver on the air conditioner's indoor unit to ensure that the airconditioner receives the signal. When the air conditioner receives a signal from the remote control, this is acknowledged by sound. The maximum distance between the remote control and air conditioner is 7 meters. This distance can also be smaller due to obstacles in this radius. Neon tubes, mobile telephones, radio devices or other electronic equipment may impair the functionality of the remote control. If this is the case, the distance to the air conditioner must be reduced when using the remote control. 2.5. Setting of time When you start the remote control for the first time after inserting batteries, the time must be reset. The procedure for this is as follows: 1. Press the button [CLOCK] (1). In addition to the display of time, “AM” or “PM” begins to blink.
18:88
AT 12:00 PM 12:01 PM 11:59 ON 12:00 3. When you have set the correct time, press the confirmation button [SET] (3). “AM”, or “PM” stops blinking.

2.6. Operation of air conditioner 2.6.1. Switching on the air conditioner Switch the air conditioner by pressing the button [ON/OFF] (1) one. The air conditioner starts operation with those settings that were set when the air conditioning unit was last shut down. When you turn on the air conditioner for the first time, the following settings are active: Operating mode: AUTO Fan speed: AUTO Timer: not active By pressing the button again [ON/OFF] (1) Turn off the air conditioner again. 2.6.2. Operating modes 2.6.2.1. Selection of the operating mode Your air conditioner supports various operating modes. These are: - AUTO - Operation - Cooling mode - Dehumidification mode - Heating mode (not all models) - Fan operation You can use the desired operating mode by pressing the button [MODE] (2) Adjustment. With each pressing of the button [MODE] (2) switches the air conditioning device to the next operating mode in the following sequence. The selected operating mode is displayed in the display of your remote control.
18:88
18:88 18:88
MODE HEALTH
CLOCK SET
CAR COOL DEHEATING MOISTURE ILATOR
LOCK RESET
A description of the different operating modes can be found on the following pages. 2.6.2.2. AUTO – Operation Activate the AUTO - operation by repeatedly pressing the button [MODE] (2). Stop when the Auto - Operating mode icon appears in your remote control display.
In the AUTO operation, the air conditioner controls all functions completely independently. At temperatures above 23 °C, the cooling mode is activated. At temperatures below 23 °C, the heating mode. The selection of the fan speed is made by means of the air conditioning device.

2.6.2.3. Cooling – Operation mode Activate the COOLING - operating mode by repeatedly pressing the button [MODE] (2). Stop when the COOL - mode icon appears in your remote control's display.
In the cooling mode, you can choose the desired room temperature yourself. In addition, you can also select the desired fan speed yourself (low, medium, high), or have the fan speed controlled by the air conditioner (fan speed - AUTO). Setting the desired temperature: Press the buttons [] FIG. [] (3) until the desired temperature is displayed on the display. The air conditioner runs until this temperature is reached. Adjustment of the desired fan speed: Press the button [FAN] (4). With each pressure, the adjusted fan speed changes as follows:
18:88
18:88 18:88
Stop when the desired speed is displayed on the screen. “AUTO” is not its own speed step. Rather, the required speed stage is selected by the air conditioning device in this setting. 2.6.2.4. Dehumidification plant Activate the dehumidification mode by repeatedly pressing the button [MODE] (2). Stop when the dehumidification mode icon appears in your remote control’s display.
MODE HEALTH
CLOCK SET
LOCK RESET
CAR COOL DEHEATING MOISTURE ILATOR
In the dehumidification mode, the air conditioning unit always runs at the lowest fan speed stage in a temperature range of +2° C. above the set temperature, independently of the set fan speed. This maximizes the dehumidification performance and at the same time does not reduce the temperature too much.

2.6.2.5. Heating mode (only models with heat pump connection) Activate the heating mode by repeated pressing of the button [MODE] (2). Stop when the Heat - Operation mode icon appears in your remote control display.
In the heating mode, you can choose the desired room temperature yourself. In addition, you can also select the desired fan speed yourself (low, medium, high), or have the fan speed controlled by the air conditioner (fan speed - AUTO). Setting the desired temperature: Press the buttons [] FIG. [] (3) until the desired temperature is displayed on the display. The air conditioner runs until this temperature is reached. Adjustment of the desired fan speed: Press the button [FAN] (4). With each pressure, the adjusted fan speed changes as follows. Stop when the desired fan speed is displayed on the screen.
18:88
18:88 18:88
SWING FAN
2.6.2.6 VENTILATOR — Operation mode Activate the heating mode by repeatedly pressing the button [MODE] (2). Stop when the Heater mode icon appears on your remote control display.
CLOCK SET
LOCK RESET
CAR COOL DEHEATING MOISTURE ILATOR
In this mode of operation, neither cooling nor dehumidification nor heating takes place. Your air conditioner works like a fan. The fan – speed you can choose: Adjustment of the desired fan speed: Press the button [FAN] (4). With each pressure, the adjusted fan speed changes as follows. Stop when the desired fan speed is displayed on the screen.
The AUTO stage is not available in fan operation.

2.6.3. Direction of blow-out setting 2.6.3.1 Wall equipment After the air conditioning unit has been switched on, depending on the selected operating mode, the air outlet automatically adjusts to the following positions:
ca. 60° Use of SWING mode Setting a specific blow-out direction Your air conditioner has motor-controlled air outlet nozzles. These can swing up and down (SWING mode) and thus provide a better distribution of the air. The air outlet nozzles oscillate in the following ranges: In cooling mode
18:88
18:88 18:88
about 10° swing range approx. 60° Activate SWING mode by pressing the button [SWING] (5). The air outlet nozzles swing up and down. By pressing the button again [SWING] (5) End the swing mode. The air outlet nozzles stop in the current situation. If you want to fix the air outlet nozzles in a specific position, first activate SWING mode as described above. Wait until the nozzles reach their desired position and press again [SWING] (5) button. The nozzles now stop in the position you want. Adjustment of the horizontal direction of blowing (manual) In addition to the vertical air outlet nozzles, your climate control unit also has horizontal air outlet valves that can be adjusted by hand as shown in the figure below.
about 10° swing range approx. 45°
CLOCK SET
LOCK RESET

motor drive. - In cooling mode you should avoid setting the air blowing direction all the way down. This can lead to
Formation of condensate in your air conditioner come, which then drips out of the device. - Also to avoid condensation we do not recommend all horizontal air outlet nozzles completely
Set to the right or left. Never set the airflow directly on yourself. This can affect your health.
ca 10°

2.6.3.2. Cassette and stand/ceiling equipment Use of SWING mode Setting a specific blow-out direction Your air conditioner has motor-controlled air outlet nozzles. These can swing up and down (SWING mode) and thus provide a better distribution of the air. Activate SWING mode by pressing the button [SWING] (5). The air outlet nozzles swing up and down. By pressing the button again [SWING] (5) End the swing mode. The air outlet nozzles stop in the current situation. If you want to fix the air outlet nozzles in a specific position, first activate SWING mode as described above. Wait until the nozzles reach their desired position and press again [SWING] (5) button. The nozzles now stop in the position you want. The vertical air blow-out direction can be adjusted by manual adjustment of the lamellae. Extended Swing Mode (only some models of stand/ceiling devices) In addition to the horizontal air outlet nozzles, the vertical air outlet valves swing left/right. Avoid adjusting the air outlet nozzles with your hand on these models. This can lead to damage of the device. Adjustment of the horizontal direction of blowing (manual) In addition to the vertical air outlet nozzles, your climate control unit also has horizontal air outlet valves that can be adjusted by hand. Attention! For devices with extended swing mode, the vertical air outlet nozzles shall not be manually adjusted. If you are not sure if your device has an advanced swing mode, check this by activating SWING Mode as described above. When the vertical air outlet nozzles move, your device has advanced swing mode.
18:88
18:88 18:88
MODE HEALTH
CLOCK SET
LOCK RESET
motor drive. - In cooling mode you should avoid setting the air blowing direction all the way down. This can lead to
Formation of condensate in your air conditioner come, which then drips out of the device. - Also to avoid condensation we do not recommend all horizontal air outlet nozzles completely
Set to the right or left. Never set the airflow directly on yourself. This can affect your health.

2.6.4. Use of timer (time switch) NOTE: Make sure the time is set correctly. You can find instructions for setting the time further up in this guide. Your air conditioner is equipped with an electronic timer. With the help of this timer, you can set times at which the air conditioner - automatically switches on - automatically turns off - automatically shuts down and back again. 2.6.4.1. Air conditioner should be automatically switched on or off at a certain time Turn on the air conditioner. Select the desired operating mode. Choose the ‘TIMER ON' or "TIME OFF" Setting by repeatedly pressing the button [TIMER] (2). With each pressing of the Timer button, the display on your remote control continues as follows:
18:88
18:88 18:88
TIMER OFF
TIMER ON-OFF
NEUTRAL
Stop when [ON] or [OFF] appears in your display. Select [ON] If you want the air conditioner to turn on at a certain time, select [OFF]If you want the air conditioner to shut down at a certain time. The [ON] or [OFF] The indicator is flashing. Now enter with the keys [] FIG. [] (3) the time at which the air conditioner is to be switched on. The time set is seen under the flashing [ON] or [OFF] Display. If you hold the button, the time starts to run faster. With each passing of the hour 12:00 changes the display "AM" to "PM", or vice versa. "AM" stands for the time until 12:00 noon, "PM" for the period after 12 o'clock noon.
MODE HEALTH
CLOCK SET
LOCK RESET
AM 12:00 PM 12:10 PM 11:50 AM 12:30 Please note that you can only set the time in 10 minutes. - You can enter steps. If you have set the time correctly, press for confirmation on [SET] (4) - button. [ON] or [OFF] stop flashing in the remote control display. The TIMER LED is illuminated on the interior unit of the air conditioner. To deactivate the timer - operation press repeatedly the button [TIMER] (2) Until neither [ON], [OFF] still [ON] [OFF] are displayed on the display.
“ ”

2.6.4.2. Air conditioner should automatically switch on and off again at a certain time Turn on the air conditioner. Select the desired operating mode. Choose the "TIMER ON OFF" Setting by repeatedly pressing the button [TIMER] (2). With each pressing of the Timer button, the display on your remote control continues as follows:
TIMER OFF
TIMER ON-OFF
NEUTRAL
Stop when [ON] [OFF] appears in your display. The [ON] The indicator is flashing. Now enter with the keys [] FIG. [] (3) the time at which the air conditioner is to be switched on. The time set is seen under the flashing [ON] Display. If you hold the button, the time starts to run faster. With each passing of the hour 12:00 changes the display "AM" to "PM", or vice versa. "AM" stands for the time until 12:00 noon, "PM" for the period after 12 o'clock noon.
AM 12:00 PM 12:10 PM 11:50 AM 12:30 Please note that you can only set the time in 10 minutes. - You can enter steps. If you have set the time correctly, press for confirmation on [TIMER] (2) - button. [ON] in the remote control display stops flashing. - Now it's flashing. [OFF] Display. Now enter with the keys [] FIG. [] (3) the time at which the air conditioner is to be switched off. The time set is seen under the flashing [OFF] Display. If you hold the button, the time starts to run faster. With each passing of the hour 12:00 changes the display "AM" to "PM", or vice versa. "AM" stands for the time until 12:00 noon, "PM" for the period after 12 o'clock noon.
18:88
18:88 18:88
MODE HEALTH
CLOCK SET
LOCK RESET
AM 12:00 PM 12:10 PM 11:50 AM 12:30 Please note that you can only set the time in 10 minutes. - You can enter steps. If you have the [OFF] When you have set the time correctly, press on to confirm that [SET] (4) - button. [ON] [OFF] stop flashing in the remote control display. The TIMER LED is illuminated on the interior unit of the air conditioner. The air conditioner now switches to the inputted [ON] Time to enter, and then [OFF] - Time out again. To deactivate the timer - operation press repeatedly the button [TIMER] (2) Until neither [ON], [OFF] still [ON] [OFF] are displayed on the display.
“ ”

2.6.5. Night Circuit (SLEEP) Your air conditioner has a so-called night circuit. The function of this night circuit is dependent on whether the heating or cooling mode is activated and will be described below. Night switching in cooling mode 1 hour after activation of the night circuit, the air conditioner increases the set temperature by 1° C. and again by 1 °C after a further hour. After a total of 6 hours, the air conditioner is switched off. So the temperature is pleasantly cool to fall asleep, but it does not become unpleasantly cold at night. Night-time heating 1 hour after activation of the night switching, the air conditioner reduces the set temperature by 1° C. and again by 1 °C after a further hour. After a total of 6 hours, the air conditioner is switched off. Thus, the temperature is pleasantly warm to fall asleep, but it does not become unpleasantly hot at night. Then activate the night. Activate the night switch by pressing the button [SLEEP] (2). The night switch is now activated. This is indicated by the corresponding icon on your remote control display. Deactivate the night switch by pressing the button again [SLEEP] (2). 2.6.6. Ionizer (Health function) (not available on all models) Your air conditioner has a function that releases negatively charged ions into the air. Negatively charged ions can filter dust and pollen from the air. Therefore, this function can create improved air conditions especially for allergy sufferers. How to activate the Health function Activate the Health function by pressing the button [HEALTH] (1). The Health function is now activated. This is indicated by the corresponding icon on your remote control display. Deactivate the Health function by pressing the button again [HEALTH] (1). 2.6.7. Automatic restart after power failure (not available on all models) Some models are equipped with an automatic restart after power failure. In this case, the air conditioning unit resumes operation with the parameters set before the power failure after a power outage. To activate the automatic restart: Turn on the air conditioner. Press 10 times within 5 seconds. [SLEEP] button (2). The apparatus produces four beep tones for the purpose of acknowledging its setting. To deactivate the automatic restart: Turn on the air conditioner. Press 10 times within 5 seconds. [SLEEP] button (2). The apparatus produces two beep tones for the purpose of acknowledging its setting.
18:88
18:88 18:88
MODE HEALTH
CLOCK SET
LOCK RESET
* For devices that do not have an ionizer function ([HEALTH] key), the [SLEEP] button may be in place of the [HEALTh] key.

With this button, turn the air conditioner on and off.
With these two buttons, you set the desired temperature.
FAN
With this button you can change the air blowing direction of the climate control unit.
With this button, select the fan speed. Low (LO) Medium (MED) High (HI) and AUTO (Automatic)**
The operating mode of the air conditioning device is set with this button. Available
MOD E SWING
FAN
With these two buttons, you set the timer.
Cooling, dehumidification and heating modes.
RESET
HEALTH
With this button, activate the ionizer.*
For the selection and programming of timer (time switch) operation.
With this button you can reset the remote to factory setting.

3.2. Description of the display Below you will find a description of the display of infrared remote control. A detailed explanation of the functions and display in the display can be found further downstream in this guide.
HEATING MODE*
COOLING
TRANSMITTING SIGNAL
“HEALTH” operation
TEMPERATURE
FAN
TIMER indicator The current fan speed is displayed.
Low Medium High Car
FAN
HEALTH
RESET
At this point, press down slightly.
3 Re-mount the battery compartment cover. Slide the cover into its correct position.
2 Put the batteries in. (Use batteries of type AAA/AM4 LR03) - Observe proper polarity of the batteries. Make sure that (+) and (-) icons match on battery and battery compartment. - Make sure both batteries are new.

3.4. Instructions for using the remote control When using the remote control, always point it towards the receiver on the air conditioner's indoor unit to ensure that the airconditioner receives the signal. When the air conditioner receives a signal from the remote control, this is acknowledged by sound. The maximum distance between the remote control and air conditioner is 7 meters. This distance can also be smaller due to obstacles in this radius. Neon tubes, mobile telephones, radio devices or other electronic equipment may impair the functionality of the remote control. If this is the case, the distance to the air conditioner must be reduced when using the remote control. 3.5. Operation of the air conditioner 3.5.1. Switching on the air conditioner Switch the air conditioner by pressing the button [ON/OFF] (1) one. The air conditioner starts operation with those settings that were set when the air conditioning unit was last shut down. When you turn on the air conditioner for the first time, the following settings are active: Operation mode: COOL fan speed: AUTO Timer: not active By pressing the button again [ON/OFF] (1) Turn off the air conditioner again. 3.5.2. Operating modes 3.5.2.1. Selection of the operating mode Your air conditioner supports various operating modes. These are: - Cooling mode - Dehumidification mode - Heating mode You can use the desired operating mode by pressing the button [MODE] (2) Adjustment. With each pressing of the button [MODE] (2) switches the air conditioning device to the next operating mode in the following sequence. The selected operating mode is displayed in the display of your remote control.
FAN
HEALTH
RESET
COOL DEHEATING MOIST
A description of the different operating modes can be found on the following pages.

3.5.2.2. Cooling – Operation mode Activate the COOLING - operating mode by repeatedly pressing the button [MODE] (2). Stop when the COOL - mode icon appears in your remote control's display.
In the cooling mode, you can choose the desired room temperature yourself. In addition, you can also select the desired fan speed yourself (low, medium, high), or have the fan speed controlled by the air conditioner (fan speed - AUTO). Setting the desired temperature: Press the buttons [] FIG. [] (3) until the desired temperature is displayed on the display. The air conditioner runs until this temperature is reached. Adjustment of the desired fan speed: Press the button [FAN] (4). With each pressure, the adjusted fan speed changes as follows:
MODE SWING
FAN
HEALTH
Stop when the desired speed is displayed on the screen. “AUTO” is not its own speed step. Rather, the required speed stage is selected by the air conditioning device in this setting. 3.5.2.3. Dehumidification plant Activate the dehumidification operation by repeatedly pressing the button [MODE] (2). Stop when the dehumidification mode icon appears in your remote control’s display.
COOL DEHEATING MOIST
In the dehumidification mode, the air conditioning unit always runs at the lowest fan speed stage in a temperature range of +2° C. above the set temperature, independently of the set fan speed. This maximizes the dehumidification performance and at the same time does not reduce the temperature too much.

3.5.2.4. Heating mode Activate the heating mode by repeatedly pressing the button [MODE] (2). Stop when the Heat - Operation mode icon appears in your remote control display.
In the heating mode, you can choose the desired room temperature yourself. In addition, you can also select the desired fan speed yourself (low, medium, high), or have the fan speed controlled by the air conditioner (fan speed - AUTO). Setting the desired temperature: Press the buttons [] FIG. [] (3) until the desired temperature is displayed on the display. The air conditioner runs until this temperature is reached. Adjustment of the desired fan speed: Press the button [FAN] (4). With each pressure, the adjusted fan speed changes as follows. Stop when the desired fan speed is displayed on the screen.
FAN
NONE. MEDIUM HIGH CAR
HEALTH
3.5.3. Direction of blow-out adjustment 3.5.3.1 Wall equipment After the air conditioning unit has been switched on, depending on the selected operating mode, the air outlet automatically adjusts to the following positions:
ca. 60° Use of SWING mode Setting a specific blow-out direction Your air conditioner has motor-controlled air outlet nozzles. These can swing up and down (SWING mode) and thus provide a better distribution of the air. The air outlet nozzles oscillate in the following ranges: In cooling mode
about 10° swing range approx. 60° Activate SWING mode by pressing the button [SWING] (5). The air outlet nozzles swing up and down. By pressing the button again [SWING] (5) End the swing mode. The air outlet nozzles stop in the current situation.
about 10° swing range approx. 45°
ca 10°

If you want to fix the air outlet nozzles in a specific position, first activate SWING mode as described above. Wait until the nozzles reach their desired position and press again [SWING] (5) button. The nozzles now stop in the position you want. Adjustment of the horizontal direction of blowing (manual) In addition to the vertical air outlet nozzles, your climate control unit also has horizontal air outlet valves that can be adjusted by hand as shown in the figure below.
3.5.3.2. Adjustment of the blow-out direction Cassette and stand/ceiling devices Use of SWING mode Setting a specific blow-off direction Your air conditioner has motor-controlled air outlet nozzles. These can swing up and down (SWING mode) and thus provide a better distribution of the air. Activate SWING mode by pressing the button [SWING] (5). The air outlet nozzles swing up and down. By pressing the button again [SWING] (5) End the swing mode. The air outlet nozzles stop in the current situation. If you want to fix the air outlet nozzles in a specific position, first activate SWING mode as described above. Wait until the nozzles reach their desired position and press again [SWING] (5) button. The nozzles now stop in the position you want. The vertical air blow-out direction can be adjusted by manual adjustment of the lamellae. Extended Swing Mode (only some models of stand/ceiling devices) In addition to the horizontal air outlet nozzles, the vertical air outlet valves swing left/right. Avoid adjusting the air outlet nozzles with your hand on these models. This can lead to damage of the device. Adjustment of the horizontal direction of blowing (manual) In addition to the vertical air outlet nozzles, your climate control unit also has horizontal air outlet valves that can be adjusted by hand as shown in the figure below. Attention! For devices with extended swing mode, the vertical air outlet nozzles shall not be manually adjusted. If you are not sure if your device has an extended
FAN
HEALTH
RESET

Swing Mode has check this by activating the SWING mode as described above. When the vertical air outlet nozzles move, your device has advanced swing mode. NOTE: Since cold air always flows downward, it makes sense to set the direction of air discharge as horizontally as possible during cooling operation. Since warm air always flows upward, it makes sense to set the direction of air blow-out in heating mode as downwardly as possible. - Avoid adjusting the vertical air outlet nozzles by hand. This may cause damage to the
motor drive. - In cooling mode you should avoid setting the air blowing direction all the way down. This can lead to
Formation of condensate in your air conditioner come, which then drips out of the device. - Also to avoid condensation we do not recommend all horizontal air outlet nozzles completely
Set to the right or left. Never set the airflow directly on yourself. This can affect your health. 3.5.4. Use of timer timing clock Your air conditioner is equipped with an electronic timer. With the help of this timer, you can set times at which the air conditioner - automatically switches on - automatically turns off 3.5.4.1. Air conditioner should be automatically switched on at a certain time Turn on the air conditioner. Select the desired operating mode. Choose the "ON" Setting by repeatedly pressing the button" [TIMER] (2). With each pressing of the Timer button, the display on your remote control continues as follows:
FAN
NEUTRAL
TIMER OFF
TIMER ON
Stop when [ON] appears in your display. Select [ON] If you want the air conditioner to turn on at a certain time. As soon as "ON" appears on the display, turns off the air conditioner. On the device, the "timer" LED lights up. Now enter with the keys [] FIG. [] (3) the time in hours, after which the air conditioner should automatically switch on. The time set is shown below the [ON] Display. Please note that you can only spend the time in 1 hour. - You can enter steps. After the set time has elapsed, the air conditioner is automatically switched on. To deactivate the timer - operation press repeatedly the button [TIMER] (2) Until neither [ON] still [OFF] are displayed on the display.
RESET
“ “

3.5.4.2. Air conditioner should be automatically switched off at certain times Turn on the air conditioner. Select the desired operating mode. Choose the "OFF" Setting by repeatedly pressing the button" [TIMER] (2). With each pressing of the Timer button, the display on your remote control continues as follows:
TIMER OFF
TIMER ON
Stop when [OFF] appears in your display. Select [OFF] If you want the air conditioner to turn off at a certain time. As soon as "OFF" on the display appears lights up the "timer" LED on the device. Now enter with the keys [] FIG. [] (3) the time in hours, after which the air conditioner is to be automatically switched off. The time set is shown below the [OFF] Display. Please note that you can only spend the time in 1 hour. - You can enter steps. After the set time has elapsed, the air conditioner is automatically switched off. To deactivate the timer - operation press repeatedly the button [TIMER] (2) Until neither [ON] still [OFF] are displayed on the display. 3.5.5. Ionizer (Health function) (not available on all models) Your air conditioner has a function that releases negatively charged ions into the air. Negatively charged ions can filter dust and pollen from the air. Therefore, this function can create improved air conditions especially for allergy sufferers. How to activate the Health function Activate the Health function by pressing the button [HEALTH] (4). The Health function is now activated. This is indicated by the corresponding icon on your remote control display. Deactivate the Health function by pressing the button again [HEALTH] (4).
FAN
HEALTH
RESET
“ “

The operating mode of the air conditioning device is set with this button. Available:
With this button, select the fan speed. Low (LO) Medium (MED) High (HI) and AUTO (Automatic)**
AUTO, cooling mode, dehumidification mode, heating mode* and fan operation.
With these buttons, you set the desired temperature.
With this button you can change the air blowing direction of the climate control unit.
CLOCK
AUTO
You need this button to set the time.
Key for confirming inputs when setting the time and timer programming
For the selection and programming of timer (time switch) operation.
With this button, activate the night switch. ****
18:88 18:88
TIME
With this button, you can reset the remote to factory settings.
With these two buttons, you set time and timer times.
EIN/AUS
With this button, turn air conditioner on and off.
Filter key

4.2. Description of the display Below you will find a description of the display of the remote control. A detailed explanation of the functions and display in the display can be found further downstream in this guide.
ADVERTISEMENT FERNBED.
FAN SWING
NIGHT-TIME SWITCHING
COLD
AUTO
SWEET
DEHUMIDIFICATION
CLOCK
FAN
HEATING
ROOM
TEMPERATURE
FENTILATOR operation
FILTER RESET
18:88 18:88
Notes * Heating mode is only available for models with heat pump circuit. ** AUTO - fan speed operation is not available for selection on some operating programs. 4.3. Setting of time When you start the remote control for the first time after inserting batteries, the time must be reset. The procedure for this is as follows: 1. Press the button [CLOCK] (1). In addition to the display of time, “AM” or “PM” begins to blink.
AUTO
CLOCK
AT 12:00 PM 12:01 PM 11:59 ON 12:00 3. When you have set the correct time, press the confirmation button [SET] (3). “AM”, or “PM” stops blinking.
18:88 18:88

4.4. Operation of air conditioner 4.4.1. Switching on the air conditioner Switch the air conditioner by pressing the button [ON/OFF] one. (1) The air conditioner starts operation with those settings that were set when the air conditioning device was last switched off. When you turn on the air conditioner for the first time, the following settings are active: Operating mode: AUTO Fan speed: AUTO Timer: not active By pressing the button again [ON/OFF] (1) Turn off the air conditioner again. 4.4.2. Operating modes 4.4.2.1. Selection of the operating mode Your air conditioner supports various operating modes. These are: - AUTO - Operation - Cooling mode - Dehumidification mode - Heating mode (not all models) - Fan operation You can use the desired operating mode by pressing the button [MODE] (2) Adjustment. With each pressing of the button [MODE] (2) switches the air conditioning device to the next operating mode in the following sequence. The selected operating mode is displayed in the display of your remote control.
AUTO
CLOCK
FILTER RESET
18:88 18:88 1
CAR COOL DEHEATING MOISTURE ILATOR
A description of the different operating modes can be found on the following pages. 4.4.2.2. AUTO – Operation Activate the AUTO - operation by repeatedly pressing the button [MODE] (2). Stop when the Auto - Operating mode icon appears in your remote control display.
In the AUTO operation, the air conditioner controls all functions completely independently. At temperatures above 23 °C, the cooling mode is activated. At temperatures below 23 °C, the heating mode. The selection of the fan speed is made by means of the air conditioning device.

4.4.2.3. Cooling – Operation mode Activate the COOLING - operating mode by repeatedly pressing the button [MODE] (2). Stop when the COOL - mode icon appears in your remote control's display.
In the cooling mode, you can choose the desired room temperature yourself. In addition, you can also select the desired fan speed yourself (low, medium, high), or have the fan speed controlled by the air conditioner (fan speed - AUTO). Setting the desired temperature: Press the buttons [] FIG. [] (3) until the desired temperature is displayed on the display. The air conditioner runs until this temperature is reached. Adjustment of the desired fan speed: Press the button [FAN] (4). With each pressure, the adjusted fan speed changes as follows:
FAN SWING
AUTO
Stop when the desired speed is displayed on the screen. “AUTO” is not its own speed step. Rather, the required speed stage is selected by the air conditioning device in this setting. 4.4.2.4. Dehumidification plant Activate the dehumidification operation by repeatedly pressing the button [MODE] (2). Stop when the dehumidification mode icon appears in your remote control’s display.
FILTER RESET
18:88 18:88 1
CAR COOL DEHEATING MOISTURE ILATOR
In the dehumidification mode, the air conditioning unit always runs at the lowest fan speed stage in a temperature range of +2° C. above the set temperature, independently of the set fan speed. This maximizes the dehumidification performance and at the same time does not reduce the temperature too much.

4.4.2.5. Heating mode (only models with heat pump connection) Activate the heating mode by repeated pressing of the button [MODE] (2). Stop when the Heat - Operation mode icon appears in your remote control display.
In the heating mode, you can choose the desired room temperature yourself. In addition, you can also select the desired fan speed yourself (low, medium, high), or have the fan speed controlled by the air conditioner (fan speed - AUTO). Setting the desired temperature: Press the buttons [] FIG. [] (3) until the desired temperature is displayed on the display. The air conditioner runs until this temperature is reached. Adjustment of the desired fan speed: Press the button [FAN] (4). With each pressure, the adjusted fan speed changes as follows. Stop when the desired fan speed is displayed on the screen.
CAR NONE. MEDIUM HIGH CAR
AUTO
CLOCK
4.4.2.6. VENTILATOR — Operation mode Activate the heating mode by repeatedly pressing the button [MODE] (2). Stop when the Heat - Operation mode icon appears in your remote control display.
18:88 18:88 1
CAR COOL DEHEATING MOISTURE ILATOR
In this mode of operation, neither cooling nor dehumidification nor heating takes place. - Your air conditioner works like a fan. The fan - speed you can choose: Adjustment of the desired fan speed: Press the button [FAN] (4). With each pressure, the adjusted fan speed changes as follows. Stop when the desired fan speed is displayed on the screen.
The AUTO stage is not available in fan operation.

4.4.3. Setting the blowing direction Use of SWING mode setting a specific blowing out direction (not all models) Your air conditioner has motor-controlled air outlet nozzles. These can swing up and down (SWING mode) and thus provide a better distribution of the air. Activate SWING mode by pressing the button [SWING] (5). The air outlet nozzles swing up and down. By pressing the button again [SWING] (5) End the swing mode. The air outlet nozzles stop in the current situation. If you want to fix the air outlet nozzles in a specific position, first activate SWING mode as described above. Wait until the nozzles reach their desired position and press again [SWING] (5) button. The nozzles now stop in the position you want. The vertical air blow-out direction can be adjusted by manual adjustment of the lamellae. Extended Swing Mode (only some models of stand/ceiling devices) In addition to the horizontal air outlet nozzles, the vertical air outlet valves swing left/right. Avoid adjusting the air outlet nozzles with your hand on these models. This can lead to damage of the device. Adjustment of the horizontal direction of blowing (manual) In addition to the vertical air outlet nozzles, your climate control unit also has horizontal air outlet valves that can be adjusted by hand. Attention! For devices with extended swing mode, the vertical air outlet nozzles shall not be manually adjusted. If you are not sure if your device has an advanced swing mode, check this by activating SWING Mode as described above. When the vertical air outlet nozzles move, your device has advanced swing mode.
AUTO
CLOCK
FILTER RESET
18:88 18:88
motor drive. - In cooling mode you should avoid setting the air blowing direction all the way down. This can lead to
Formation of condensate in your air conditioner come, which then drips out of the device. - Also to avoid condensation we do not recommend all horizontal air outlet nozzles completely
Set to the right or left. Never set the airflow directly on yourself. This can affect your health.

4.4.4. Use of timer (time switch) NOTE: Make sure the time is set correctly. You can find instructions for setting the time further up in this guide. Your air conditioner is equipped with an electronic timer. With the help of this timer, you can set times at which the air conditioner - automatically switches on - automatically turns off - automatically shuts down and back again. 4.4.4.1. Air conditioner should be automatically switched on or off at a certain time Turn on the air conditioner. Select the desired operating mode. Choose the ‘TIMER ON' or "TIME OFF" Setting by repeatedly pressing the button [TIMER] (2). With each pressing of the Timer button, the display on your remote control continues as follows:
AUTO
TIMER ON
TIMER OFF
TIMER ON-OFF
NEUTRAL
CLOCK
Stop when [ON] or [OFF] appears in your display. Select [ON] If you want the air conditioner to turn on at a certain time, select [OFF]If you want the air conditioner to shut down at a certain time. The [ON] or [OFF] The indicator is flashing. Now enter with the keys [] FIG. [] (3) the time at which the air conditioner is to be switched on. The time set is seen under the flashing [ON] or [OFF] Display. If you hold the button, the time starts to run faster. With each passing of the hour 12:00 changes the display "AM" to "PM", or vice versa. "AM" stands for the time until 12:00 noon, "PM" for the period after 12 o'clock noon.
18:88 18:88 1
AM 12:00 PM 12:10 PM 11:50 AM 12:30 Please note that you can only set the time in 10 minutes. - You can enter steps. If you have set the time correctly, press for confirmation on [SET] (4) - button. [ON] or [OFF] stop flashing in the remote control display. The TIMER LED is illuminated on the interior unit of the air conditioner. To deactivate the timer - operation press repeatedly the button [TIMER] (2) Until neither [ON], [OFF] still [ON] [OFF] are displayed on the display.
“ ”

4.4.4.2. Air conditioner should automatically switch on and off again at a certain time Turn on the air conditioner. Select the desired operating mode. Choose the "TIMER ON OFF" Setting by repeatedly pressing the button [TIMER] (2). With each pressing of the Timer button, the display on your remote control continues as follows:
TIMER OFF
TIMER ON-OFF
NEUTRAL
Stop when [ON] [OFF] appears in your display. The [ON] The indicator is flashing. Now enter with the keys [] FIG. [] (3) the time at which the air conditioner is to be switched on. The time set is seen under the flashing [ON] Display. If you hold the button, the time starts to run faster. With each passing of the hour 12:00 changes the display "AM" to "PM", or vice versa. "AM" stands for the time until 12:00 noon, "PM" for the period after 12 o'clock noon.
AM 12:00 PM 12:10 PM 11:50 AM 12:30 Please note that you can only set the time in 10 minutes. - You can enter steps. If you have set the time correctly, press for confirmation on [TIMER] (2) - button. [ON] in the remote control display stops flashing. - Now it's flashing. [OFF] Display. Now enter with the keys [] FIG. [] (3) the time at which the air conditioner is to be switched off. The time set is seen under the flashing [OFF] Display. If you hold the button, the time starts to run faster. With each passing of the hour 12:00 changes the display "AM" to "PM", or vice versa. "AM" stands for the time until 12:00 noon, "PM" for the period after 12 o'clock noon.
CLOCK
FILTER RESET
18:88 18:88 1
AM 12:00 PM 12:10 PM 11:50 AM 12:30 Please note that you can only set the time in 10 minutes. - You can enter steps. If you have the [OFF] When you have set the time correctly, press on to confirm that [SET] (4) - button. [ON] [OFF] stop flashing in the remote control display. The TIMER LED is illuminated on the interior unit of the air conditioner. The air conditioner now switches to the inputted [ON] Time to enter, and then [OFF] - Time out again. To deactivate the timer - operation press repeatedly the button [TIMER] (2) Until neither [ON], [OFF] Still [ON] [OFF] are displayed on the display.
“ ”

4.4.5. Night shift Your air conditioner has a so-called night circuit. The function of this night circuit is dependent on whether the heating or cooling mode is activated and will be described below. Night switching in cooling mode 1 hour after activation of the night circuit, the air conditioner increases the set temperature by 1° C. and again by 1 °C after a further hour. After a total of 6 hours, the air conditioner is switched off. So the temperature is pleasantly cool to fall asleep, but it does not become unpleasantly cold at night. Night-time heating 1 hour after activation of the night switching, the air conditioner reduces the set temperature by 1° C. and again by 1 °C after a further hour. After a total of 6 hours, the air conditioner is switched off. Thus, the temperature is pleasantly warm to fall asleep, but it does not become unpleasantly hot at night. Then activate the night. Activate the night switch by pressing the button [SLEEP] (2). The night switch is now activated. This is indicated by the corresponding icon on your remote control display. Deactivate the night switch by pressing the button again [SLEEP] (2). 4.4.6. Automatic restart after power failure (not available on all models) Some models are equipped with an automatic restart after power failure. In this case, the air conditioning unit resumes operation with the parameters set before the power failure after a power outage. To activate the automatic restart: Turn on the air conditioner. Press 10 times within 5 seconds. [SLEEP] button (2). The apparatus produces four beep tones for the purpose of acknowledging its setting. To deactivate the automatic restart: Turn on the air conditioner. Press 10 times within 5 seconds. [SLEEP] button (2). The apparatus produces two beep tones for the purpose of acknowledging its setting.
CLOCK
FILTER RESET
18:88 18:88

With these two buttons, you set the desired temperature.
With this button, turn the air conditioner on and off.
CLOCK
You need this button to set the time.
With these two buttons, you set time and timer times.
With this button you can change the air blowing direction of the climate control unit.
For the selection and programming of timer (time switch) operation.
TEMP TIME
MODE FAN SPEED
The operating mode of the air conditioning device is set with this button. Available:
Key for confirming inputs when setting the time and timer programming
AUTO, cooling mode, dehumidification mode, heating mode* and fan operation.
With this button, activate the night switch.
With this button, select the fan speed. Low (LO) Medium (MED) High (HI) and AUTO (Automatic)**

5.2. Description of the display Below you will find a description of the display of infrared remote control. A detailed explanation of the functions and display in the display can be found further downstream in this guide.
AUTO operation
COOLING
DEHUMIDIFICATION
AM PM 18:88
ROOM TEMP SET TEMP
TIME
, IF APPLICABLE - OPERATION
TIMER switch-on time
NIGHT-TIME SWITCHING
SWING TIMER CLOCK
TEMP TIME
TIMER shutdown time
MODE FAN SPEED
HEATING MODE
Fan speed
TEMPERATURE The current fan speed is displayed.
Niedrig Medium High Car
Notes: * Heating mode is only available for models with heat pump circuit. ** AUTO - fan speed operation is not available for selection on some operating programs. 5.3. Setting of time When you start the remote control for the first time after inserting batteries, the time must be reset. The procedure for this is as follows: 1. Press the button [CLOCK] (1). In addition to the display of time, “AM” or “PM” begins to blink.
AT 12:00 PM 12:01 PM 11:59 ON 12:00 3. When you have set the correct time, press the confirmation button [SET] (3). “AM”, or “PM” stops blinking.

5.4. Operation of the air conditioner 5.4.1. Switching on the air conditioner Switch the air conditioner by pressing the button [ON/OFF] one. (1) The air conditioner starts operation with those settings that were set when the air conditioning device was last switched off. When you turn on the air conditioner for the first time, the following settings are active: Operating mode: AUTO Fan speed: AUTO Timer: not active By pressing the button again [ON/OFF] (1) Turn off the air conditioner again. 5.4.2. Operating modes 5.4.2.1. Selection of the operating mode Your air conditioner supports various operating modes. These are: - AUTO - Operation - Cooling mode - Dehumidification mode - Heating mode (not all models) - Fan operation You can use the desired operating mode by pressing the button [MODE] (2) Adjustment. With each pressing of the button [MODE] (2) switches the air conditioning device to the next operating mode in the following sequence. The selected operating mode is displayed in the display of your remote control.
TEMP TIME
CAR COOL DEHEATING MOISTURE ILATOR
A description of the different operating modes can be found on the following pages. 5.4.2.2. AUTO – Operation Activate the AUTO operation by repeatedly pressing the [MODE] (2) button. Stop when the Auto - Operating mode icon appears in your remote control display.
In the AUTO operation, the air conditioner controls all functions completely independently. At temperatures above 23 °C, the cooling mode is activated. At temperatures below 23 °C, the heating mode. The selection of the fan speed is made by means of the air conditioning device.

5.4.2.3. Cooling – Operation mode Activate the COOLING - operating mode by repeatedly pressing the button [MODE] (2). Stop when the COOL - mode icon appears in your remote control's display.
In the cooling mode, you can choose the desired room temperature yourself. In addition, you can also select the desired fan speed yourself (low, medium, high), or have the fan speed controlled by the air conditioner (fan speed - AUTO). Setting the desired temperature: Press the buttons [] FIG. [] (3) until the desired temperature is displayed on the display. The air conditioner runs until this temperature is reached. Adjustment of the desired fan speed: Press the button [FAN] (4). With each pressure, the adjusted fan speed changes as follows:
Low Medium Hoch Car
Stop when the desired speed is displayed on the screen. “AUTO” is not its own speed step. Rather, the required speed stage is selected by the air conditioning device in this setting. 5.4.2.4. Dehumidification plant Activate the dehumidification mode by repeatedly pressing the button [MODE] (2). Stop when the dehumidification mode icon appears in your remote control’s display.
TEMP TIME
CAR COOL DEHEATING MOISTURE ILATOR
In the dehumidification mode, the air conditioning unit always runs at the lowest fan speed stage in a temperature range of +2° C. above the set temperature, independently of the set fan speed. This maximizes the dehumidification performance and at the same time does not reduce the temperature too much.

5.4.2.5. Heating mode (only models with heat pump connection) Activate the heating mode by repeated pressing of the button [MODE] (2). Stop when the Heat - Operation mode icon appears in your remote control display.
In the heating mode, you can choose the desired room temperature yourself. In addition, you can also select the desired fan speed yourself (low, medium, high), or have the fan speed controlled by the air conditioner (fan speed - AUTO). Setting the desired temperature: Press the buttons [] FIG. [] (3) until the desired temperature is displayed on the display. The air conditioner runs until this temperature is reached. Adjustment of the desired fan speed: Press the button [FAN] (4). With each pressure, the adjusted fan speed changes as follows. Stop when the desired fan speed is displayed on the screen.
Low Medium Hoch Car
5.4.2.6. VENTILATOR — Operation mode Activate the heating mode by repeatedly pressing the button [MODE] (2). Stop when the Heat - Operation mode icon appears in your remote control display.
In this mode of operation, neither cooling nor dehumidification nor heating takes place. - Your air conditioner works like a fan. The fan - speed you can choose: Adjustment of the desired fan speed: Press the button [FAN] (4). With each pressure, the adjusted fan speed changes as follows. Stop when the desired fan speed is displayed on the screen.
Low Medium Hoch Car
The AUTO stage is not available in fan operation.

5.4.3. Setting the blowing direction Use of SWING mode setting a specific blowing out direction Your air conditioner has motor-controlled air outlet nozzles. These can swing up and down (SWING mode) and thus provide a better distribution of the air. Activate SWING mode by pressing the button [SWING] (5). The air outlet nozzles swing up and down. By pressing the button again [SWING] (5) End the swing mode. The air outlet nozzles stop in the current situation. If you want to fix the air outlet nozzles in a specific position, first activate SWING mode as described above. Wait until the nozzles reach their desired position and press again [SWING] (5) button. The nozzles now stop in the position you want. The vertical air blow-out direction can be adjusted by manual adjustment of the lamellae. Extended Swing Mode (only some models of stand/ceiling devices) In addition to the horizontal air outlet nozzles, the vertical air outlet valves swing left/right. Avoid adjusting the air outlet nozzles with your hand on these models. This can lead to damage of the device. Adjustment of the horizontal direction of blowing (manual) In addition to the vertical air outlet nozzles, your climate control unit also has horizontal air outlet valves that can be adjusted by hand. Attention! For devices with extended swing mode, the vertical air outlet nozzles shall not be manually adjusted. If you are not sure if your device has an advanced swing mode, check this by activating SWING Mode as described above. When the vertical air outlet nozzles move, your device has advanced swing mode.
TEMP TIME
motor drive. - In cooling mode you should avoid setting the air blowing direction all the way down. This can lead to
Formation of condensate in your air conditioner come, which then drips out of the device. - Also to avoid condensation we do not recommend all horizontal air outlet nozzles completely
Set to the right or left. Never set the airflow directly on yourself. This can affect your health.

5.4.4. Use of timer timing clock NOTE: Make sure the time is set correctly. You can find instructions for setting the time further up in this guide. Your air conditioner is equipped with an electronic timer. With the help of this timer, you can set times at which the air conditioner - automatically switches on - automatically turns off - automatically shuts down and back again. 5.4.4.1. Air conditioner should be automatically switched on or off at a certain time Turn on the air conditioner. Select the desired operating mode. Choose the ‘TIMER ON' or "TIME OFF" Setting by repeatedly pressing the button [TIMER] (2). With each pressing of the Timer button, the display on your remote control continues as follows:
TIMER OFF
TIMER ON-OFF
NEUTRAL
Stop when [ON] or [OFF] appears in your display. Select [ON] If you want the air conditioner to turn on at a certain time, select [OFF]If you want the air conditioner to shut down at a certain time. The [ON] or [OFF] The indicator is flashing. Now enter with the keys [] FIG. [] (3) the time at which the air conditioner is to be switched on. The time set is seen under the flashing [ON] or [OFF] Display. If you hold the button, the time starts to run faster. With each passing of the hour 12:00 changes the display "AM" to "PM", or vice versa. "AM" stands for the time until 12:00 noon, "PM" for the period after 12 o'clock noon.
TEMP TIME
AM 12:00 PM 12:10 PM 11:50 AM 12:30 Please note that you can only set the time in 10 minutes. - You can enter steps. If you have set the time correctly, press for confirmation on [SET] (4) - button. [ON] or [OFF] stop flashing in the remote control display. The TIMER LED is illuminated on the interior unit of the air conditioner. To deactivate the timer - operation press repeatedly the button [TIMER] (2) Until neither [ON], [OFF] still [ON] [OFF] are displayed on the screen.
“ ”

5.4.4.2 Air conditioner should automatically switch on and off again at a certain time Turn on the air conditioner. Select the desired operating mode. Choose the "TIMER ON OFF" Setting by repeatedly pressing the button [TIMER] (2). With each pressing of the Timer button, the display on your remote control continues as follows:
TIMER OFF
TIMER ON-OFF
NEUTRAL
Stop when [ON] [OFF] appears in your display. The [ON] The indicator is flashing. Now enter with the keys [] FIG. [] (3) the time at which the air conditioner is to be switched on. The time set is seen under the flashing [ON] Display. If you hold the button, the time starts to run faster. With each passing of the hour 12:00 changes the display "AM" to "PM", or vice versa. "AM" stands for the time until 12:00 noon, "PM" for the period after 12 o'clock noon.
AM 12:00 PM 12:10 PM 11:50 AM 12:30 Please note that you can only set the time in 10 minutes. - You can enter steps. If you have set the time correctly, press for confirmation on [TIMER] (2) - button. [ON] in the remote control display stops flashing. - Now it's flashing. [OFF] Display. Now enter with the keys [] FIG. [] (3) the time at which the air conditioner is to be switched off. The time set is seen under the flashing [OFF] Display. If you hold the button, the time starts to run faster. With each passing of the hour 12:00 changes the display "AM" to "PM", or vice versa. "AM" stands for the time until 12:00 noon, "PM" for the period after 12 o'clock noon.
TEMP TIME
AM 12:00 PM 12:10 PM 11:50 AM 12:30 Please note that you can only set the time in 10 minutes. - You can enter steps. If you have the [OFF] When you have set the time correctly, press on to confirm that [SET] (4) - button. [ON] [OFF] stop flashing in the remote control display. The TIMER LED is illuminated on the interior unit of the air conditioner. The air conditioner now switches to the inputted [ON] Time to enter, and then [OFF] - Time out again. To disable the timer operation, press repeatedly the [TIMER] (2) button until neither [ON], [OFF] Still [ON] [OFF] are displayed on the display.
“ ”

5.4.5. Night Circuit (SLEEP) Your air conditioner has a so-called night circuit. The function of this night circuit is dependent on whether the heating or cooling mode is activated and will be described below. Night switching in cooling mode 1 hour after activation of the night circuit, the air conditioner increases the set temperature by 1° C. and again by 1 °C after a further hour. After a total of 6 hours, the air conditioner is switched off. So the temperature is pleasantly cool to fall asleep, but it does not become unpleasantly cold at night. Night-time heating 1 hour after activation of the night switching, the air conditioner reduces the set temperature by 1° C. and again by 1 °C after a further hour. After a total of 6 hours, the air conditioner is switched off. Thus, the temperature is pleasantly warm to fall asleep, but it does not become unpleasantly hot at night. Then activate the night. Activate the night switch by pressing the button [SLEEP] (2). The night switch is now activated. This is indicated by the corresponding icon on your remote control display. Deactivate the night switch by pressing the button again [SLEEP] (2). 5.4.6. Automatic restart after power failure (not available on all models) Some models are equipped with an automatic restart after power failure. In this case, the air conditioning unit resumes operation with the parameters set before the power failure after a power outage. To activate the automatic restart: Turn on the air conditioner. Press 10 times within 5 seconds. [SLEEP] button (2). The apparatus produces four beep tones for the purpose of acknowledging its setting. To deactivate the automatic restart: Turn on the air conditioner. Press 10 times within 5 seconds. [SLEEP] button (2). The apparatus produces two beep tones for the purpose of acknowledging its setting.
TEMP TIME

Pay attention to the set temperature. It can harm your health if the temperature difference between indoor and outdoor temperature is more than 7 °C. We recommend never setting the temperature lower than 3-5°C to outside. Furthermore, it can harm your health if you are directly exposed to the airflow of the climate control unit.



Clean the air filters of the climate control unit regularly. Polluted air filters affect the performance of your climate control unit, as well as the air quality.
Clean the filter every 4 weeks.

Keep windows and doors closed while the air conditioner is in operation, and if possible pull curtains to avoid direct sunlight.
Keep the windows and doors closed!


Use the timer properly. Make sure that the set operating time is sufficient to reach the desired temperature.
Use the timer meaningfully!
When cleaning the air conditioner, make sure that no water can enter the unit.

Make sure that in the case of interior and exterior unit neither air intake nor air outlet through objects such as furniture, curtains, etc. are concealed.

The air conditioning unit is provided with a restart inhibitor for protecting the compressor. The cooling/heating mode does not start until 3 minutes after the unit has been switched on.
The air conditioner does not start cooling/heating immediately after being switched on.
After the device is switched on, or immediately after it has been turned off, a hissing or gargling noise may be heard. This is a refrigerant that flows into the air conditioner. This sound is most noticeable in the first three minutes of operation, then decreases and finally stops.
A sound is heard.
Odors that are in the air (tobacco smell, kitchen odors, dust) are circulated by the climate control unit. These odors can be particularly unpleasant due to the concentrated airflow of the climate control unit. - Clean the air filters regularly and ventilate the room at regular intervals.
The air conditioner emits an unpleasant odor.
At very high humidity, the sudden cooling of the air can cause the humic moisture to precipitate and become perceptible as mist or steam. With increasing operating time of the air conditioning device, the fog is no longer visible.
Steam/mist is blown out of the air conditioner.
Is the air conditioner powered? - Did the fuse jump? - Is there a power outage?
Air conditioner does not work at all.
- Is the air filter contaminated? The air filter should be all 4
weeks are cleaned. - Are there objects in front of the interior or
Exterior unit that hinders airflow? - Is the temperature set correctly? - When cooling lower than room temperature. - When operating in heating operation higher than the room temperature. - Is the fan set at too low a level? Are the windows or doors open? - Is there strong sunlight, which is caused by curtains
Air conditioner does not cool, or insufficiently.
Or could the shutters be prevented? Are there too many people in the room? Are there too many heat sources in operation? (excluding electrically operated)
Devices - computer, etc., or cooking stations, heating devices

7.1. Advanced troubleshooting for devices with fault diagnosis (not available for all devices) 7.1.1 Monosplit - Air conditioners with cable remote control Type 2 Your air conditioner has a self-diagnosis and is able to detect and display certain disturbances. If such a failure occurs, the air conditioner service light will flash and an error code (“E”+ digit) is displayed on the display instead of temperature. In such a case, please note the error code displayed and notify your climate specialist company. A description of the fault codes, possibilities for troubleshooting and repair is contained in the installation manual of the air conditioner. In the event of these and any other faults on the air conditioner, disconnect the air-conditioning unit from the power supply and notify your specialist air conditioning company.
12:00
7.1.2. Inverter multi-split air conditioners Your air conditioner has a self-diagnosis and is able to detect and display certain disturbances. 7.1.2.1. Infrared remote-control equipment In the case of devices with infrared remote control, fault messages are displayed on an air conditioner via a flashing timer and/or operating LED. Count with how often the timer and / or operating LED flashes, write down the number and communicate your air conditioning specialist company. A description of the fault codes, possibilities for troubleshooting and repair is contained in the installation manual of the air conditioner. In the event of these and any other faults on the air conditioner, disconnect the air-conditioning unit from the power supply and notify your specialist air conditioning company. Note: A flashing timer - LED indicates error on the interior device. A flashing operation - LED indicates error on the outdoor device. If timer and operation LED flash at the same time, there is a fault on both the interior and exterior device. Count first with the timer - LED and write down the value, and then with the operation - LED, and write up the value. The error codes are independent. Lighting up of timer and operation together - LED has no meaning of its own. 7.1.2.2. Cable remote-control devices When a failure occurs, the air conditioner service light will flash and an error code (“E”+ digit) is displayed on the display instead of temperature. In such a case, please note the error code displayed and notify your climate specialist company. A description of the fault codes, possibilities for troubleshooting and repair is contained in the installation manual of the air conditioner. In the event of these and any other faults on the air conditioner, disconnect the air-conditioning unit from the power supply and notify your specialist air conditioning company.
12:00

8. Emergency operation (only for wall devices) Your air conditioner has emergency operation in case your remote control is defective or lost. To activate the emergency operation, press the emergency mode - switch. The air conditioner acknowledges the actuation of the switch with a "biep" sound. The air conditioner now runs in the AUTO operating mode. No other settings can be chosen. 9. Test operation (only for wall devices) To check the function of your air conditioner, even if the room temperature is below 16°C (lower operating limit), your air-conditioning unit has a test mode. To activate the test mode, press the emergency operation switch. The air conditioner acknowledges the actuation of the switch with a "biep" sound. Hold the switch for about 5 seconds until a second "biep" sound is heard. Then leave the switch off. The air conditioning unit starts in the cooling mode with the fan speed “high”. 9.1. End of emergency or test operation To end the emergency operation or test operation, you have two options: - Press again the emergency operating switch. Again


Then there is a "biep" signal. Emergency or test operation is terminated. - Press any button on the remote control.
Emergency or test operation is terminated.



before you start cleaning. - Use a soft cloth for cleaning. - In case of heavy pollution, use it for cleaning
A mild cleansing agent (no scrubbing agents) and a wet cloth. - Wrap the cloth well to prevent water from entering the interior of the air conditioner. 10.1.2. Remote control cleaning Use a soft cloth for cleaning If you have severe pollution, use a mild cleanser (no scrubbing agents) and wet cloth to clean. - Wrap the cloth well to prevent water from entering the interior of the air conditioner.


10.1.3. Cleaning of air filters 1 Open the air outlet grill by touching it on the side and pulling forward slightly.
3 Clean the air filter with a brush-mounted vacuum cleaner. In case of heavy pollution, you can spray off the filter in a shower or bathtub. Use a mild cleanser. Before reinserting the filters, make sure they are completely dried. Do not expose the filters to direct sunlight when drying.




2 Take the air filters. To do this, push the air filter a little upward until the pins at the bottom of the air cleaner come out of the anchorage. Then pull the air filter down to remove it from the climate control unit.
4 Reset the air filter. The air filter is marked “FRONT” on one side. Make sure this page points to you. - Make sure that the air filter is in the guide rails. - Press the air filter slightly upwards and let the pins snap into the bracket.





10.2. Ground/ceiling equipment You can carry out the following maintenance work yourself: - External cleaning of air conditioning unit - Cleaning of remote control - Cleansing of air filters 10.2.1. External cleaning of the air conditioning unit - Turn off the power supply of the air conditioner,

before you start cleaning. - Use a soft cloth for cleaning. - In case of heavy pollution, use it for cleaning
A mild cleansing agent (no scrubbing agents) and a wet cloth. - Wrap the cloth well to prevent water from entering the interior of the air conditioner. 10.2.2. Remote control cleaning Use a soft cloth for cleaning If you have severe pollution, use a mild cleanser (no scrubbing agents) and wet cloth to clean. - Wrap the cloth well to prevent water from entering the interior of the air conditioner.
10.2.3. Cleaning of air filters (appliances up to 5 kW cooling capacity) 1 Open the air intake grille by touching it on the side and pulling forward slightly. The grill is secured in the middle with a hook and can be opened about 3 cm.
3 Clean the air filter with a brush-mounted vacuum cleaner. In case of heavy pollution, you can spray off the filter in a shower or bathtub. Use a mild cleanser. Before reinserting the filters, make sure they are completely dried. Do not expose the filters to direct sunlight when drying.


Approximately 30 mm in diameter
4 Reset the air filter. The air filter is marked “FRONT” on one side. Make sure that this side points to you. - Make sure that the air filter is in the lower bracket. - Allow the air filter to snap in on top of the bracket. - Close the air intake grille again. Make sure the grid snaps in on its sides and center.
2 Take the air filters. To do this, press the air filter a little backwards (toward the climate control) until the pin at the top of the air purifier comes out of the anchorage. Then pull the air filter up to remove it from the climate control unit.






10.2.4. Cleaning of air filters (equipment with a cooling capacity exceeding 5 kW) 1 Press the buttons on the front of the air filter until you notice a clearly audible click. The filter jumps out of the holder and stands out a bit.
3 Clean the air filter with a brush-mounted vacuum cleaner. In case of heavy pollution, you can spray off the filter in a shower or bathtub. Use a mild cleanser. Before reinserting the filters, make sure they are completely dried. Do not expose the filters to direct sunlight when drying.

4 Reset the air filter. The air filter is marked “FRONT” on one side. Make sure that this side points to you. - Make sure that the air filter is located in the guide rails. - Push the filter completely into the holder. - Press the buttons on the front of the air filter. When the air filter snaps into the anchorage, a clear click can be heard. When the air filter is properly seated in the anchorage, it does not protrude forward.
2 Take the air filters. For this purpose, grip the air filter with both hands and pull it obliquely upwards from the guide rail. Take the air filters.

10.3. Cassette-type apparatus You can carry out the following maintenance work yourself: - External cleaning of air conditioning unit - Cleaning of remote control - Cleansing of air filters 10.3.1. External cleaning of the air conditioning unit - Turn off the power supply of the air conditioner,
before you start cleaning. - Use a soft cloth for cleaning. - In case of heavy pollution, use it for cleaning
A mild cleansing agent (no scrubbing agents) and a wet cloth. - Wrap the cloth well to prevent water from entering the interior of the air conditioner. 10.3.2. Remote control cleaning Use a soft cloth for cleaning If you have severe pollution, use a mild cleanser (no scrubbing agents) and wet cloth to clean. - Wrap the cloth well to prevent water from entering the interior of the air conditioner.

10.3.3. Cleaning of air filters (Appliances with filter lift) 1 Press the FILTER button on your air conditioner remote control. The air intake grille with the air filter is lowered on four cables.
3 Clean the air filter with a brush-mounted vacuum cleaner. In case of heavy pollution, you can spray off the filter in a shower or bathtub. Use a mild cleanser. Before reinserting the filters, make sure they are completely dried. Do not expose the filters to direct sunlight when drying.
4 Reset the air filter. - Make sure that the air filter is placed in the brackets
2 Turn the white locking lever to the side. Lift the filter on the side where the locking lever is located and pull it from the holder on the opposite side of the locking arm.
on the side opposite to the locking lever. - Turn the locking lever over via air filter
fix it. - Press the FILTER button on the remote control
your air conditioner. The air intake grille with the air filter lifts and closes off with the diaphragm.

10.3.4. Cleaning of the suction grid (Appliances with filter lift) 1 Press the FILTER button on your air conditioner remote control. The air intake grille with the air filter is lowered on four cables.
2 At those points at which the suction grid hangs on the cables, they run through white guide rollers. The guide rollers are inserted into a base which has one side of a wide opening and the other side of an narrow opening. Push the guide roller towards the wide opening out of the base. Repeat the process for all four leadership roles.
Cable guide roller width opening

3 Clean the suction screen. Please note the following information: - Use lukewarm water, no hot water. - Use a soft cloth or sponge. - Use a mild, diluted cleanser, not scrubber milk. - Leave the suction grid well before re-installing
your air conditioner. The air intake grille with the air filter lifts and closes off with the diaphragm.
drying.
4 Push the guide rollers back onto the base in reverse order of removal from the side of the wide opening of the pedestal.
Cable guide roller width opening
Intake grille while it hangs on the ropes does not carry weight. This can lead to damage of the filter lift.
10.3.5. Cleaning of air filters (devices without filter lift) 1 Open the air intake grille by pressing together the two buttons on the side of the intake grate. Open the suction screen slowly.
3 Clean the air filter with a brush-mounted vacuum cleaner. In case of heavy pollution, you can spray off the filter in a shower or bathtub. Use a mild cleanser. Before reinserting the filters, make sure they are completely dried. Do not expose the filters to direct sunlight when drying.

2 Take the air filters. To do this, press the air filter a little upwards (toward the climate control unit) until the pins at the end of the air cleaner come out of the anchorage. Then pull the air filter down to remove it from the climate control unit.
4 Reset the air filter. - Make sure that the air filter is placed in the upper

The holder is located. - Leave the air filter in the lower bracket
snapping in. - Close the air intake grille again. Beware
It's just like the grid snapping on the sides.


10.3.6. Cleaning of the suction grid (devices without filter lift) 1 Open the air intake grille by compressing the two buttons on the side of the intake grate. Open the suction screen slowly.
4 Clean the suction screen. Please note the following information: - Use lukewarm water, no hot water. - Use a soft cloth or sponge. - Use a mild, diluted cleanser, not scrubber milk. - Leave the suction grid well before re-installing
drying.
2 Take the air filters. (See “Cleaning the Air Filters” on front page.) 3 Take the suction grid. To do this, hold the intake burr at an angle of 45° and press the grid slightly upwards. Do not use force. - You could damage the grid.
5 Re-insert the suction grid in reverse order of extraction.
6 Re-insert the air filters and close the intake grille. (See “Cleaning the Air Filters” on front page.)

10.3.7. Dismantling and cleaning of air guide vanes (Appliances without filter lift) To clean the air guide vanes you need a screwdriver. 1 With the help of the remote control, fix the air guide vanes so that the attachments at both ends are visible and accessible. (See “SWING” mode further forward in this user manual).
3 Clean the air guide vane. Please note the following information: - Use lukewarm water, no hot water. - Use a soft cloth or sponge. - Use a mild, diluted cleanser, not scrubber milk. - Leave the air duct well before re-installing
drying.
2 Open and remove the screws at both ends of the air guide vane. Hold the air guide vane on one side and bend it slightly downward until it comes out of the anchorage and can be removed.
4 Re-insert the air guide vane in reverse order of removal. Re-tighten the screws without using force.



10.4. Sewerage and ceiling-mounted equipment The following maintenance work can be carried out yourself: - Cleaning of the remote control 10.4.1. Remote control cleaning Use a soft cloth for cleaning If you have severe pollution, use a mild cleanser (no scrubbing agents) and wet cloth to clean. - Wrap the cloth well to prevent water from entering the interior of the air conditioner.