Page 1 of the Gys TF 4R user manual — WELDING FUMES AND GAS
Page 1 · click to enlarge
Page 1

WARNING - SAFETY RULES

GENERAL INSTRUCTIONS

Read and understand the following safety recommendations before using or servicing the unit. Any change or servicing that is not specified in the instruction manual must not be undertaken.

The manufacturer is not liable for any injury or damage caused due to non-compliance with the instructions featured in this manual . In the event of problems or uncertainties, please consult a qualified person to handle the installation properly. Read the welding machine’s instruction manual before using the wire feeder.

ENVIRONMENT

This equipment must only be used for welding and gouging operations in accordance with the limits indicated on the descriptive panel and/or in the user manual. The operator must respect the safety precautions that apply to this type of welding. In case of inedaquate or unsafe use, the manufacturer cannot be held liable for damage or injury.

This equipment must be used and stored in a place protected from dust, acid or any other corrosive agent. Operate the machine in an open, or well-ventilated area.

Operating temperature: Use between -10 and +40°C (+14 and +104°F). Store between -25 and +55°C (-13 and 131°F).

Air humidity: Lower or equal to 50% at 40°C (104°F).

Lower or equal to 90% at 20°C (68°F).

Altitude: Up to 2000 meters above sea level (6500 feet).

INDIVIDUAL PROTECTIONS AND OTHERS

Arc welding can be dangerous and can cause serious and even fatal injuries. Welding exposes the user to dangerous heat, arc rays, electromagnetic fields, noise, gas fumes, and electrical shocks. People wearing pacemakers are advised to consult with their doctor before using this device. Protect yourself and others. Ensure the following safety precautions are taken:

In order to protect you from burns and radiations, wear clothing without cuffs. These clothes must be insulated, dry, fireproof and in good condition, and cover the whole body.

Wear protective gloves which guarantee electrical and thermal insulation.

Use sufficient welding protective gear for the whole body: hood, gloves, jacket, trousers... (variable depending on the application/ operation). Protect your eyes during cleaning operations. Do not operate whilst wearing contact lenses. It may be necessary to install fireproof welding curtains to protect the area against arc rays, weld spatters and sparks. Inform the people around the working area to never look at the arc ray or the molten metal, and to wear protective clothes.

Ensure ear protection is worn by the operator if the work exceeds the authorised noise limit. Ensure ear protection is worn by anyone in the welding area .

Stay away from moving parts (e.g. engine, fan...) with hands, hair, clothes etc... Never remove the safety covers from the cooling trolley when the machine is plugged in - The manufacturer is not responsible for any accident or injury that happens as a result of not following these safety precautions.

The pieces that have just been welded are hot and may cause burns when manipulated. During maintenance work on the torch, you should make sure it’s cold enough and wait at least 10 minutes before any intervention. The cooling trolley must be on when using a water cooled torch in order to ensure that the liquid does not cause any burns. ALWAYS ensure the working area is left as safe and secure as possible to prevent damage or accidents.

WELDING FUMES AND GAS

The fumes, gases and dust produced during welding are hazardous. It is mandatory to ensure adequate ventilation and/or extraction to keep fumes and gases away from the work area. An air fed helmet is recommended in cases of insufficient air supply in the workplace. Check that the air intake is in compliance with safety standards.

Caution, welding in small work areas requires surveillance from a safe distance. Welding certain pieces of metal containing lead, cadmium, zinc, mercury or beryllium can be extremely toxic. The user will also need to degrease the workpiece before welding. Gas cylinders must be stored in an open or ventilated area. The cylinders must be in a vertical position secured to a support or trolley. Do not weld in areas where grease or paint are stored. 8

Page 2 of the Gys TF 4R user manual — ELECTROMAGNETIC INTERFERENCES
Page 2 · click to enlarge
Page 2

FIRE AND EXPLOSIONS RISKS

Protect the entire welding area. Compressed gas containers and other inflammable material must be moved to a minimum safe distance of 11 meters. A fire extinguisher must be readily available. Be careful of spatter and sparks, even through cracks. It can be the source of a fire or an explosion.

Keep people, flammable objects and containers under pressure at a safe distance. Welding of sealed containers or closed pipes should not be undertaken, and if opened, the operator must remove any inflammable or explosive materials (oil, petrol, gas...). Grinding operations should not be directed towards the device itself, the power supply or any flammable materials.

GAS BOTTLE

Gas leaking from the cylinder can create a hazard if present in high concentrations around the work area. Transport must be done safely: Cylinders closed and product off. Always keep cylinders in an upright position securely chained to a fixed support or trolley.

Close the bottle after any welding operation. Be careful with gas bottles placed in areas of high temperature, or in sunlight. Cylinders should be located away from areas where they may be struck or subjected to physical damage. Always keep gas bottles at a safe distance from arc welding or cutting operations, and any source of heat, sparks or flame. Be careful when opening the valve on the gas bottle, it is necessary to remove the tip of the valve and make sure the gas meets your welding requirements.

ELECTRIC SAFETY

The machine must be connected to an earthed electrical supply. Use the recommended fuse size. An electrical discharge can directly or indirectly cause serious or deadly accidents.

Do not touch any live part of the machine (inside or outside) when it is plugged in (Torches, earth cable, cables, electrodes) because they are connected to the welding circuit. Before opening the device, it is imperative to disconnect it from the mains and wait 2 minutes, so that all the capacitors are discharged. Do not touch the torch or electrode holder and earth clamp at the same time. Damaged cables and torches must be changed by a qualified and skilled professional. Make sure that the cable cross section is adequate with the usage (extensions and welding cables). Always wear dry clothes in good condition, in order to be insulated from the electrical circuit. Wear insulating shoes, regardless of the environment in which you work in.

EMC CLASSIFICATION

These Class A devices are not intended to be used on a residential site where the electric current is supplied by the public network, with a low voltage power supply. There may be potential difficulties in ensuring electromagnetic compatibility on these sites, because of the interferences, as well as radio frequencies.

These devices are not compliant with the CEI 61000-3-12 standard. On a public low-voltage power grid, it is the responsibility of the installer or user of the device to ensure, by checking with the operator of the distribution network, which device can be connected.

ELECTROMAGNETIC INTERFERENCES

The electric currents flowing through a conductor cause electrical and magnetic fields (EMF). The welding current generates an EMF field around the welding circuit and the welding equipment.

The EMF fields may disrupt some medical implants, such as pacemakers. Protection measures should be taken for people wearing medical implants. For example, access restrictions for passers-by or an individual risk evaluation for the welders.

All welders should take the following precautions in order to minimise exposure to the electromagnetic fields (EMF) generated by the welding circuit:: – position the welding cables together – if possible, attach them; – keep your head and torso as far as possible from the welding circuit; – never enroll the cables around your body; – never position your body between the welding cables. Hold both welding cables on the same side of your body; – connect the earth clamp as close as possible to the area being welded; – do not work too close to, do not lean and do not sit on the welding machine – do not weld when you’re carrying the welding machine or its wire feeder. 9

Page 3 of the Gys TF 4R user manual — MAINTENANCE / RECOMMENDATIONS
Page 3 · click to enlarge
Page 3

People wearing pacemakers are advised to consult their doctor before using this device. Exposure to electromagnetic fields while welding may have other health effects which are not yet known.

TRANSPORT AND TRANSIT OF THE WIRE FEEDER

The wire feeder is equipped with handles for easy transportation. Be careful not to underestimate the machine’s weight. The handle cannot be used to hang the machine from other equipment. If you wish to lift the wire feeder, please use the optional lifting support (ref. 036277). Never lift the machine while there is a gas cylinder on the support shelf. A clear path is available when moving the item. Do not place/carry the unit over people or objects. The removal of the wire reel from the machine is recommended before undertaking any lifting operation.

Stray welding currents/voltages may destroy earth conductors, damage electrical equipment or cause components to warm up which may cause a fire.

- All welding connections must be firmly secured, check regularly ! - Check that the metal piece fixation is strong and without any electrical problems ! - Attach or hang all the electrically conductive elements,such as the trolley in order to insulate them - Do not place any electrical equipment such as drills on top of the welding machine without insulating them ! - Always place welding torches or electrodes holders on an insulated surface when they’re not in use !

INSTALLATION

  • Rules to follow :
  • The wire feeder must be switched on with all access panels closed.
  • Put the wire feeder on a floor with a maximum incline of 10°.
  • The machine must be placed in a sheltered area away from rain or direct sunlight.
  • The equipment’s protection level is IP21, which means : - Protection against acess to dangerous parts from solid bodies of a ≥12.5mm diameter and, - Protection against the rain vertical.

The manufacturer does not incur any responsability regarding damages to both objects and persons that result from an incorrect and/or dangerous use of the machine .

MAINTENANCE / RECOMMENDATIONS

  • Maintenance should only be carried out by a qualified person. Annual maintenance is recommended.
  • Ensure the wire feeder is disconnected from the welding machine, and wait for two minutes before carrying out maintenance work.
  • Remove the casing 2 or 3 times a year to remove any excess dust. Take this opportunity to have the electrical connections checked by a qualified person, with an insulated tool.
  • Regularly check the connection cable between the wire feeder and the machine. If damaged, the connection cable cable must be replaced.
  • Warning ! If the welding machine is transported/handled by another solution than the one recommended by the manufacturer; the wire feeder casing must be insulated from the transporting/handling solution. Rules to follow :
  • The wire feeder must be switched on with all access panels closed.
Page 4 of the Gys TF 4R user manual — COMPATIBILITY
Page 4 · click to enlarge
Page 4

INSTALLATION – PRODUCT OPERATION

Only qualified personnel authorized by the manufacturer should perform the installation of the welding equipment. During set up, the operator must ensure that the machine is unplugged.

  • Risk of injury due to moving parts! The wire feeders contain moving parts that may catch hand, hair, clothes or tools which can lead to injuries! Take extra care.
  • Do not place your hand on mobile/pivoting/wire feeding parts of the machine!
  • Make sure that all panels remain closed when in use !

DESCRIPTION

TF 4R is an air-cooled separate wire feeder for the 3-phase MIG/MAG generators MIG 400G/400 DUO. It accepts 200 and 300 mm wire reels. The TF 4R is equipped with a swivel support to be fixed on the generator.

DEVICE PRESENTATION (I)

1- Reel support (200 or 300mm) 2- Wire feeder 3- Handle 4- Wire speed potentiometer 5- Euro torch connector 6- Lateral torch holder 7- Wheels

8- Upper section of the swivel support 9- Gas connector 10- Control cable connector 11- Power cable connector 12- Black plastic support for the wire feeder

ASSEMBLY & CONNECTION (II)

Installing the swivel support on the generator The black plastic support for the wire feeder is packed within the wire feeder. Remove the retaining screw then the black plastic support. Use the 3 screws supplied to fix the bottom part of the swivel support onto the generator. The upper part of the support is already fixed under the wire feeder.

Gas Coupling Fit the gas pipe to the connectors (12) and (13) located at the back of the generator (pipes and collars not included).

Connection to the generator Make sure the generator is switched off before performing this operation. Connect the wire feeder to the generator, making sure that the power and water connectors are securely tightened (11).

WIRE REEL INSTALLATION (III)

  • Open the door of the machine et remove the retaining screw (3)
  • Position the reel on to the support (1).
  • Adjust the reel brake (2) to avoid reel movement tangling the wire when the welding stops. Be careful not to tighten too much - the reel must rotate without straining the motor.
  • Tighten the plastic screw firmly (3).
  • For the first use : - Release the fixing screw of the wire guide (4) - Put the rollers in place (5). The visible diameter on the roller should be equal to the wire diameter used. - Place the wire guide (6) as close as possible to the roller but without touching it, then tighten the fixing screw.
  • To select the adjustment of the drive rollers: loosen the drive roller knob as far as possible (7), insert the wire until it exits the other side by about 2cm. Start the motor by pressing the torch trigger, tighten the knob whilst pressing the trigger. Bend the wire where it comes out of the nozzle and hold it in place to stop its progress - the setting is correct when the guide roller slides over the wire, even when it is blocked at the end of the torch.

USE

TF 4R allows the user welding using the parameters set on the MIG generator. To adjust the settings to the type and diameter of wire used, please refer to the generator’s manual. It is possible to change the wire speed, in synergic or manual mode using the potentiometer on the front panel. In order to use the separate wire feeder’s torch, press the trigger - the LEDs on the generator’s control panel will start to flash, indicating the change of torch. The Speed of the wire feeder is between 1m/min to 20m/min. The maximum gas pressure must not exceed 10 bars (1MPa).

COMPATIBILITY

The wire feeder TF-4R is only compatible with the PROMIG / POWERMIG range. Please refer to the electrical drawing for technical features of the wire feeder motor.

Page 5 of the Gys TF 4R user manual — MACHINE MAINTENANCE DETAILS
Page 5 · click to enlarge
Page 5

TROUBLESHOOTING

SymptomsReasonsSolutions There are sparks between the electrode and the filler wire.Metal fillings have accumulated on the drive roller.Clean the drive roller and the reels with an airgun. Failure to start weldingNo gasGas valve closed or bottle empty The gas is continuousSolenoid valve blocked or dirtyRemove, check and clean the solenoid valve. The torch overheatsThe torch is not suitable for the wire feeder duty cycleChange the torch for a one which is suitable for the machine The welding wire speed is not constant.The wire skids in the rollersCheck the roller pressure or replace it. Frein de bobine trop serréDesserrer en agissant sur la vis de frein de la bobine de fil Covering wire guide in the torchVérifier la torche incompatible.Vérifier la pression des galets Reel brake too tightAdjust the reel brake The torch is bent which might inhibit the wire outputCheck the torch The rollers slide over the wireCheck and tighten the roller screws Sheath crushedChange it Roller grooves do not match the diameter of wire usedChange for size suitable for wire used.

MACHINE MAINTENANCE DETAILS

Machine maintenance or alteration should only be carried out by a qualified person. Failure to comply may void the warranty. Any maintenance or action performed on the machine should be done with power supply off (machine disconnected from the power supply network), wait at least 5 minutes before any operation, block access to the installation if necessary.

Daily : - Check the torch, the rollers and the tightening, the connections.

Twice a year : - Clean the inside of the machine with a compressed air cleaner. - Make sure not to put any conductor inside the machine, such as the torch. - Check the wear and coupling of the connections, retighten if necessary. - Check the following parts: electrical, gas, wire reel support, wire-feeding motor and bottle support.

Page 6 of the Gys TF 4R user manual — 10 Connecteur de commande/ Connector / Connector / Conectador de mando 53086
Page 6 · click to enlarge
Page 6

TF 4R

PIÈCES DÉTACHÉES / SPARE PARTS / ERSATZTEILE/ PIEZAS DE RECAMBIO/ ЗАПЧАСТИ

1 Support bobine / Wire reel support / Drahtförderrollen / Soporte bobina 71603

2 Motodévidoir / Wire feeder / Drahtvorschub / Devanadera 51257

3 Potentiomètre / Potentiometer / Potentiometer / Potenciómetro 73009

4 Circuit / Board / Karte / Carta 97184C

5 Roues / Wheels / Räder/ Ruedas 71181

6 Tourelle / Swivel support / Bewegbahrehalterung / Sosten giratorio 72006

7 Poignée / Handle / Griff / Puño 56047

8 Support torche / Torch support / Brennerhalter/ Soporte antorcha 98689BG

9 Connecteur gaz / Gas connector / Gasanschlussbuchse / conector de gas / Газовый коннектор 71699

10 Connecteur de commande/ Connector / Connector / Conectador de mando 53086

11 Connecteur T50 / T50 connector / Texasbuchse / Conectador T50 51461

Page 7 of the Gys TF 4R user manual — 60% 270A
Page 7 · click to enlarge
Page 7

TF 4R

SPÉCIFICATIONS TECHNIQUES / TECHNICAL SPECIFICATIONS / TECHNISCHE DATEN / ТЕХНИЧЕСКИЕ СПЕЦИФИКАЦИИ

TF 4R

Tensions d’alimentation (DC) – issues du générateur / Power supply voltage (DC) – generator output / Versorgungsspannung (DC) – aus dem Generator / Напряжения питания (DC) – из источника / Tensione di alimentazione (DC) - creata dal generatore / Voedingsspanning (DC) - afkomstig uit het lasapparaat

U 1 = 24V-3A

Vitesse de moteur / Motor speed / Versorgungsspannung (DC) – aus dem Generator / Скорость двигателя / Velocità del motore / Snelheid motor 1.0-20.0 m/mn

Connectique de torche / Torch connector / Brenneranschluss / Соединения горелки / Connettori della torcia / Aansluiting toorts EURO

Bobines supportées / Supported wire reels / geeignete Drahtspulen / Подходящие бобины / Bobine sup portate / Ondersteunde spoelen 200 mm / 300 mm

Fe0.6 mm – 1.2 mm
SS0.8 mm – 1.2 mm

Fils supportés / Supported wires / geeignete Drähte / Подходящие виды проволоки / Fili supportati / Ondersteunde draden

Al1.0 mm – 1.2 mm
Cored0.9 mm – 1.2 mm

Facteur de marche à 40°C (10 min)* Norme EN60974-1. Duty cycle at 40°C (10 min)* Standard EN60974-1. Einschaltdauer @ 40°C (10 min)* EN60974-1-Norm. ПВ% при 40°C (10 мин)* Норма EN60974-1. Ciclo di lavoro a 40°C (10 min)* Norma EN60974-1. Inschakelduur bij 40°C (10 min)* Norm EN60974-1.

60% 270A

100% 220A

Fonction du matériau à souder Depending on the material to weld

Gaz de protection / Protectice gas / Schutzgas / Защитный газ / Gas di protezione / Beschermingsgas (Pmax = 5 bar)

материала Funzione del materiale da saldare Functie van het te lassen materiaal

Type de galet / Drive roller type / Drahtführungsrolle-Typ / Tipo de rodillo / Тип ролика / Type draa daanvoerrol / Tipo di rullo

B (ext. Ø 37 mm / int. Ø 9 mm)

Température de fonctionnement / Functionning temperature / Betriebstemperatur / Рабочая температура / Temperatura di funzionamento / Gebruikstemperatuur -10°C +40°C

Température de stockage / Storage temperature / Lagertemperatur / Lagerungstemperatur / Температура хранения / Temperatura di stoccaggio / Bewaartemperatuur -25°C +55°C

Degré de protection / Protection level / Schutzart / Степень защиты / Grado di protezione / Beschermings klasse IP21

Dimensions (Lxlxh) / Dimensions (LxWxH) / Abmessungen (LxBxT) / Размеры (ДхШхВ) / Dimensioni (Lxlxh) / Afmetingen (Lxbxh) 24 x 55 x 44 cm

Poids / Weight / Gewicht / Вес / Peso / Gewicht 14.5 kg

Функция свариваемого

Page 8 of the Gys TF 4R user manual — U 2
Page 8 · click to enlarge
Page 8

TF 4R TF 4R

ICÔNES / ICONS / ZEICHEN / СИМВОЛЫ

- Attention ! Lire le manuel d’instruction avant utilisation. - Caution ! Read the user manual. - Achtung! Lesen Sie die Betriebsanleitung. - Cuidado, leer las instrucciones de utilización. - Внимание ! Читайте инструкцию по использованию. - Let op! Lees voorzichtig de gebruiksaanwijzing. - Attenzione! Leggere il manuale d’istruzioni prima dell’uso.

- Le dévidoir est conforme à la norme IEC 60974-5. - The wire feeder complies with the IEC 60974-5 standard. - Der Drahtvorschubkoffer entspricht der Norm IEC 60974-5.

- Подающее устройство соответствует норме IEC 60974-5. - Il trainafilo è conforme alla norma IEC 60974-5. - Het draadaanvoersysteem voldoet aan de eisen van de norm IEC 60974-5.

IEC 60974-5

- Symbole du dévidoir. - Wire feeder symbol. - Drahtvorschubsymbol

- Символ подающего устройства. - Simbolo del trainafilo. - Symbool van het draadaanvoersysteem.

- Protection contre l’accès aux parties dangereuses des corps solides de Ø ≥12,5mm et chute d’eau. - Protected against the access of dangerous parts from solid bodies of a Ø ≥12,5mm and water. - Gegen Eindringen von Körpern mit einem Durchmesser >12,5mm und gegen Sprühwasser geschützt. - Защита от попадания в опасные зоны твердых тел Ø ≥12,5мм и капель воды. - Protezione contro l’accesso alle aree pericolose di corpi solidi di Ø ≥12,5mm e cadute d’acqua. - Beveiligd tegen toegang tot gevaarlijke delen van Ø ≥12,5mm, en tegen regendruppels.

IP21

- Courant de soudage continu. - Direct welding current. - Invertergleichstromquelle (DC)

- Постоянный сварочный ток. - Corrente di saldatura continua. - DC lasstroom

- Facteur de marche selon la norme EN60974-1 (10 minutes – 40°C). - Duty cycle according to standard EN 60974-1 (10 minutes – 40°C). - Einschaltdauer @ 40°C (10 min)* EN60974-1-Norm.

- ПВ% согласно норме EN 60974-1 (10 минут – 40°C). - Ciclo di lavoro conforme alla norma EN60974-1 (10 minuti – 40°C). - Inschakelduur volgens de norm EN60974-1 (10 minuten – 40°C).

X(40°C)

- Courant de soudage conventionnnel correspondant. - Corresponding conventional welding current. - Entsprechender Schweißstrom.

- Соответствующий номинальный сварочный ток. - Corrente di saldatura convenzionale corrispondente. - Overeenkomstige conventionele lasstroom.

- U2: Tensions conventionnelles en charges correspondantes. - U2: conventional voltages in corresponding load. - U2: entsprechende Arbeitsspannung.

- U2: Tensiones convencionales en carga. - U2: соответствующие сварочные напряжения - Overeenkomstige conventionele lasstroom.

U 2

A Ampères - Amperes - Амперы - Amper - Ampère

- Appareil(s) conforme(s) aux directives européennes. La déclaration de conformité est disponible sur notre site internet. - Machine(s) compliant with European directives The declaration of conformity is available on our website. - Dieses Gerät entspricht den europäischen Normen. Die Konformitätserklärung befindet sich auf unseren Internetseite. - Aппарат(ы) соответствует(ют) европейским директивам. Декларация соответствия есть на нашем сайте. - Dispositivo(i) conforme(i) alle direttive europee. La dichiarazione di conformità è disponibile sul nostro sito internet. - Appara(a)t(en) conform aan de Europese richtlijnen. Het certificaat van overeenstemming is beschikbaar op onze internet site.

- Знак соответствия EAC (Евразийское экономическое сообщество). - Marchio di conformità EAC (Comunità economica Eurasiatica). - EAC (Euraziatische Economische Gemeenschap) merkteken van overeenstem ming

- Marque de conformité EAC (Communauté économique Eurasienne). - EAEC Conformity marking (Eurasian Economic Community). - EAC-Konformitätszeichen (Eurasische Wirtschaftsgemeinschaft)

Produit dont le fabricant participe à la valorisation des emballages en cotisant à un système global de tri, collecte sélective et recyclage des déchets d’emballages ménagers. / Product whose manufacturer is involved in the packaging’s recycling process by contributing to a global system of sorting, collecting and recycling of households’ packa ging waste. / Für die Entsor-gung Ihres Gerätes gelten besondere Bestimmungen (Sondermüll). / Producto sobre el cual el fabricante participa mediante una valorización de los embalajes cotizando a un sistema global de separación, recogida selectiva y reciclado de los deshechos de embalajes domésticos. / Продукт, производитель которого участвует в переработке упаковки путем отчислений в глобальную систему сортировки, раздельного сбора и переработки отходов упаковки. / De fabrikant van dit produkt neemt deel aan de inzameling en de recycling van afval door bij te dragen aan een globaal inzamel- en recyclesysteem van verpakkingen van huishoudelijk afval. / Il fabbricante partecipa alla valorizzazione delle confezioni grazie a dei versamenti ad un sis-tema globale di smistamento, coletta selettiva e riciclaggio dei rifiuti di imballaggi domestici.

Produit recyclable qui relève d’une consigne de tri (selon le décret n°2014-1577). / Recy-clable product that falls within waste sorting recommendations. / Recyclingpro dukt, der durch Mülltrennung entsorgt werden muss. / Producto reciclable que requiere una separación determinada. / Перерабатываемый продукт, подпадаемый под определенные правила сортировки. / Afzonderlijke inzameling vereist. Gooi dit produkt niet bij het huishoudelijk afval. / Prodotto riciclabile soggetto a raccolta selettiva.

- Ce matériel fait l’objet d’une collecte sélective selon la directive européenne 2012/19/UE. Ne pas jeter dans une poubelle domestique ! - This hardware is subject to waste collection according to the European directives 2002/96/UE. Do not throw out in a domestic bin/waste ! - Für die Entsorgung Ihres Gerätes gelten besondere Bestimmungen (Elektroschrott) gemäß europäische Bestimmung 2012/19/EU. Es darf nicht mit dem Hausmüll entsorgt werden. - Это оборудование подлежит переработке согласно директиве Евросоюза 2012/19/UE. Не выбрасывать в общий мусоросборник! - Questo dispositivo è oggetto di raccolta differenziata secondo la direttiva europea 2012/19/UE. Non gettare nei rifiuti domestici ! - Afzonderlijke inzameling vereist volgens de Europese richtlijn 2012/19/UE. Gooi het apparaat niet bij het huishoudelijk afval !

- Information sur la température (protection thermique). - Temperature information (thermal protection). - Information zur Temperatur (Thermoschutz)

- Информация по температуре (термозащита). - Informazioni sulla temperatura (protezione termica). - Informatie over de temperatuur (thermische beveiliging).

- Purge gaz - Gas purge - Gasventil einschalten

- Epurazione del gas - Afvoeren gas

- Entrée du gaz - Gas input - Gasanschluss

- Подача газа. - Entrata del gas. - Ingang gas.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
There are sparks between the electrode and the filler wire.Metal fillings have accumulated on the drive roller.Clean the drive roller and the reels with an air- gun. p.5
Failure to start weldingNo gasGas valve closed or bottle empty p.5
The gas is continuousSolenoid valve blocked or dirtyRemove, check and clean the solenoid valve. p.5
The torch overheatsThe torch is not suitable for the wire feeder duty cycleChange the torch for a one which is suitable for the machine p.5
The welding wire speed is not constant.The wire skids in the rollersCheck the roller pressure or replace it. p.5
The welding wire speed is not constant.Frein de bobine trop serréDesserrer en agissant sur la vis de frein de la bobine de fil p.5
The welding wire speed is not constant.Covering wire guide in the torchVérifier la torche p.5
The welding wire speed is not constant.incompatible.Vérifier la pression des galets p.5
The welding wire speed is not constant.Reel brake too tightAdjust the reel brake p.5
The welding wire speed is not constant.The torch is bent which might inhibit the wire outputCheck the torch p.5
The welding wire speed is not constant.The rollers slide over the wireCheck and tighten the roller screws p.5
The welding wire speed is not constant.Sheath crushedChange it p.5
The welding wire speed is not constant.Roller grooves do not match the diameter of wire usedChange for size suitable for wire used. p.5

Ask about the Gys TF 4R

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Gys TF 4R

Be the first to ask — other owners or our team will answer.

Original document

Gys TF 4R manual PDF

31 pages·1.8 MB·Welder·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…