EN
Gutmann logo
Official user manual

Gutmann Nube

48 pages·993 KB·Kitchen Range Hood·PDF·ENJA
Gutmann Nube
Table of Contents 15 sections Instruction Manual Hood Nube · Security advice · General Functionality: · Operation by remote control · … ShowHide
Page 1 of the Gutmann Nube user manual — Instruction Manual Hood Nube
Page 1 · click to enlarge
Page 1

Instruction Manual Hood Nube

Thank you for deciding to purchase a Gutmann exhaust hood.

Please carefully read the following information and explanations regarding the proper use of your new Gutmann hood before first using it. Please take note of our cleaning recommendation so that you can enjoy your new advice for as long as possible.

Dear customer,

Page 2 of the Gutmann Nube user manual — General Functionality:
Page 2 · click to enlarge
Page 2

under ward. Over-fated filters signify fire risk! Deep-fry under the extractor hood only under constant ward! Please make sure that the filters are cleaned regularly. „Flambé“ under the extractor hood is not permitted! Gas devices may be used under the extractor hood only with pots on! Please run the extractor hood on level 2 or higher if you use more than 3 gas cookeries at the same time. Thereby a heat accumulation in the appliance is avoided.

Security advice

This instruction manual contains important and helpful hints which must be followed for a safe and trouble-free operation of the extractor hood. Please keep the operating and assembly instructions in a safe place for re-consultation.

Designated use The extractor hood should be used solely for removing moisture and cooking odours in the kitchen. Any other usage is considered to be improper. An improper usage of the extractor can endanger persons and items. The extractor hood should not be used as a clipboard for subjects like for example bottles or spice cans.

Risk of electric shock! Please do not clean the extractor hood with a steam cleaner or high water pressure. Please separate the extractor hood from the power supply network and pay attention to the fact that no water seeps into the appliance during the cleaning process.

Subject to technical modifications!

Installation The appliance should be connected only by an authorized expert according to all re- levant regulations of the electricity supply enterprises as well as the building regulations of the countries. Please pay attention to the assembly instructions!

General Functionality:

The exhaust hood has been specially developed for the exhaust of cooking vapors in private households. The filigree hood body consists of two safety glass panels, where the lower glass panel is pivotable for the extraction of the filters.

Damaged units should not be used. Faulty parts should be replaced by original ones. Repairs should be carried out only by authorized technical staff.

For this suction slots are arranged centrally in the lower glass panel which effectively collect the ascending cooking vapors and suction them off via a metal filter (double- condensation filter) (in case of circulating air, additionally with activated charcoal filter). The metal filter is held in the hood body by means of magnets.

Risk of poisoning! If the extractor hood with an integrated supercharger for exhaust air management (version B) is operated at the same time with other heat-producing appliances dependent on air room (e.g. run by wood, gas, oil or coal) deadly combustion gases can be led back into the room by an accruing under pressure. Therefore please make sure that at any time a sufficient supply air flow is provided. The low pressure in the room should not be greater than 4 Pa (0.04mbar).

In case of these bonnets, the metal filter is concealed by a pivotable glass panel. The glass panels are arranged at a separation distance from each other such that a suction slot arises between the glass elements all round, which results in very efficient suction exhaust.

The extractor hood should never be used without a fat filter and should be operated

Risk of fire!

Page 3 of the Gutmann Nube user manual — Operation by remote control
Page 3 · click to enlarge
Page 3

The suction power is controlled over the operator panel / remote control. Alongside the illumination, additional functions are also controlled via the control panel on certain models. Multiple halogen spotlights illuminate the cooking area.

The functions of the bonnet model, as well as the fan power of the external motor, can be controlled using two alternative procedures:

1. Operation by remote control (recommended) 2. Operation by switches

The exhaust hood is constructed from stainless steel in conjunction with glass front for hygienic reasons.

Operation by remote control

Operating instructions

Button 1Function 1 - ON / OFF operation
Gutmann Nube — Operation by remote control diagram (page 3)
Fig. 1 · Operation by remote control

Function 2 - delayed switch-off time (activation of the delayed switch-off time through repeated pressing of Key 1; the ceiling device then switches down a power stage automatically within a short time, until the final disconnection)

Button 2Fan power in the sequence 1-2-

3-2-1 of the individual power stages

Gutmann Nube — Operation by remote control diagram (page 3)
Fig. 2 · Operation by remote control

1 Upper tower 2 Lower tower 3 LED display 4 Safety glass panel, pivoting 5 Halogen illumination 6 Metal filters 7 ON - OFF switch 8 Sensor 9 Suction slots

Page 4 of the Gutmann Nube user manual — LED display (located on the Upper tower)
Page 4 · click to enlarge
Page 4
Button 3Intensive stage (motor switches
LED 2Fan power Stage 1 (low motor power)

automatically back to Stage 3 after 3 min)

Press once Button 2 of the remote control

Button 4Light ON / OFF, through longer

pressing lighting can be dimmed. Battery chamber 5: Please em- ploy batteries of the Type AA exclusively

LED 3Fan power Stage 2 (medium motor

Press twice Button 2 of the remote control

Operation by switches (located on the Upper tower below the plate)

Pressing the switch to the left: Light ON / OFF Pressing the switch to the right: Control of the fan power

LED 4Fan power stage 3 (high motor po

Pressing the switch for 3 sec to the right: Bonnet is switched off.

Press three times Button 2 of the remote control

The filter saturation indication is likewise reset over this switch. Keep the switch pressed to the right until the red LED goes out.

LED 5Intensive stage (motor switches

back to Stage 3 automatically after 3 min)

LED display (located on the Upper tower)

Press Button 3 of the remote control

LED 6Filter saturation display

Specifications of the operational state of the bonnet can be read off on the LED display of the device:

With lighting of the red LED, the metal filters are to be cleaned (see section on cleaning and maintenance). The filter saturation indication lights up 14-active or approx. 15 hours of operation.

Gutmann Nube — LED display (located on the Upper tower) diagram (page 4)
Fig. 3 · LED display (located on the Upper tower)

In te n s ive s ta g e :

F ilte r s a tu ra tio n In d ic a to r:

LED 1Display ON / OFF operating status
LED 1 flashingDisplay automatic delay switch-off time

(The bonnet switches down a power stage automatically every 5 min, until the final disconnection)

power) · twice · wer)

Page 5 of the Gutmann Nube user manual — Cleaning of the surface
Page 5 · click to enlarge
Page 5

Remove / Clean the Grease Filter

Cleaning and care

Risk of Fire! The performance of the exhaust hood is affected by greasy debris; In order to avoid the risk of fire, be certain to regularly clean the metal filter. In the case of these metal filters double-condensation filters are involved which must be cleaned the latest every two weeks.

Cleaning of the surface

Risk of electric shock! Please separate the extractor hood from the power supply network by pulling the plug or the disconnection of the fuse. Please pay attention to the fact that no water seeps into the appliance during the cleaning process. Untimely cleaning of the surface saves later a troublesome removing of stubborn soiling. For the cleaning use only commercial detergent or all-purpose cleaners which are suitable for stainless steel / aluminium. Please do not use scouring agents or steel wool! After the cleaning of the extractor hood please tend the stainless steel surfaces with a high- grade steel-care product.Only with a light soapy water and a very soft cloth varnished surfaces have to be cleaned. Please clean the switch panel only with a soft and damp- dry cloth.By extractor hoods with a gass fronts beneath the metal grease filter (“Pe- rimeter Extraction”) fatty deposits can occur on the edge of the glass fronts. These deposits are founded physically and represent no dysfunction of the extractor hood. Please clean the glass fronts beneath the filter regularly to prevent stubborn soiling.

In order to remove the metal filter, the glass panel must be pressed down with both hands until it locks. Hold the metal filter with both hands on the grips and move down until the magnetic contact releases. Now the metal filter can be removed downwards. Reassembly takes place in the reverse order.

Gutmann Nube — Cleaning of the surface diagram (page 5)
Fig. 4 · Cleaning of the surface
Gutmann Nube — Cleaning of the surface diagram (page 5)
Fig. 5 · Cleaning of the surface

Before that, clean the metal filter parts where you screw off the filter grips for that. Now the metal filter can be disassembled into individual filter plates. The cleaning is best carried out in the dishwasher with a mild dishwasher cleaning agent.

The manufacturer offers no guarantee in the event of possible discoloration through the use of aggressive cleaning products. Temperatures above 65 degrees should also be avoided.

Page 6 of the Gutmann Nube user manual — Exchange of the active carbon filter
Page 6 · click to enlarge
Page 6

trichloroethylene, etc. will lead to the destruction of the filter!

Lighting change

Screw the metal filter together again after cleaning and insert into the bonnet. After that, the glass panel must be placed into its initial location again. To do this, guide the glass panel upwards with both hands until the quick locks snap into place

Defective illuminants must be exchanged immediately.

De-energized exhauster hood before the replacement of the illuminants! The lighting remains hot for a long time. Please wait until they have cooled before changing them.

Exchange of the active carbon filter

Gutmann Nube — Exchange of the active carbon filter diagram (page 6)
Fig. 6 · Exchange of the active carbon filter

(only extractor hoods with circular air – version D) Active carbon filters bundle up odorous substances which are contained in the kitchen fume. According to the strain of work this filter has to be exchanged after 3-6 months.

Gutmann Nube — Exchange of the active carbon filter diagram (page 6)
Fig. 7 · Exchange of the active carbon filter

After cooling down, the illuminant must be held at the edge with both fingers, then move the illuminant down carefully (plug-in receptacle) until the illuminant is released from the socket. It is absolutely necessary to avoid contact with the skin during the insertion of the new illuminant; employ a clean cloth to do this.The installation of a new illuminant is

The active carbon filter is often mounted on a frame sitting below the ventilator module. For the exchange of the active carbon filter turn both black toggle screws around 90 degrees. After flapping down the pane and taking out the frame the filter can be changed easily. The installation is made in reverse order. By some extractor hoods the active carbon filter is directly mounted on the metal filter. After the removal of the metal filters take the charcoal filter out and substitute it by a new one. Important: please do not clean the active carbon filter with water or any other liquid.

Page 7 of the Gutmann Nube user manual — Technical data
Page 7 · click to enlarge
Page 7

Dysfunctions

Disposal

Please refer to our customer service if

Packaging The packaging of the appliance is recyclable. It is made up off cardboard and polyethylene foil (PE). Please dispose these materials in a environmentally aware, responsible way and in accordance with the regulations of your local authority.

- the extractor hood produces too much undefined noise and the control of the exhaust air path reveils no faults; - the supercharger works faulty; - the circuit operates invalid.

Please indicate your type of extractor hood and the series number. These informations are mentioned on the type sheet which is situated inside the hood on the filter. mplemented in reverse order.

Extractor hood Your local community will be able to advise you on an environmentally compatible disposal of sorted out household appliances.

Enviromental information

This appliance is labelled in accordance with the European Directive 2002/96/EG conceming used electrical and electronic appliances (waste electrical and electronic equipment - WEEE). The guideline determines the framework for the return and recycling of used appliances as applicable throughout the EU. Please ask your dealer about current means of disposal.

Technical data

Connection mains230 V / 50 Hz, max. 500 watt Lighting: halogen Paulmann Maxi

Flood (12V, 20 Watt)

Page 8 of the Gutmann Nube user manual — Dysfunctions
Page 8 · click to enlarge
Page 8
Page 8 of the Gutmann Nube user manual — Dysfunctions

Ask about the Gutmann Nube

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Gutmann Nube

Be the first to ask — other owners or our team will answer.

Original document

Gutmann Nube manual PDF

48 pages·993 KB·Kitchen Range Hood·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…