EN
Gutmann logo
Official user manual

Gutmann Capa

24 pages·1.4 MB·Kitchen Range Hood·PDF·ENFRITJA
Gutmann Capa
Table of Contents 5 sections GUTMANN to help you enjoy life · Instruction Manual · Technical data · - + · … ShowHide
Page 1 of the Gutmann Capa user manual — GUTMANN to help you enjoy life
Page 1 · click to enlarge
Page 1

GUTMANN to help you enjoy life

Thank you for choosing a GUTMANN extractor hood.

Please carefully read the following information and explanations on the proper use of your new GUTMANN hood before using the appliance for the first time. Please also read our operating and installation instructions as well as the cleaning recommenda- tions to ensure that you enjoy many years of service from your appliance.

Dear customer,

Page 2 of the Gutmann Capa user manual — GUTMANN to help you enjoy life
Page 2 · click to enlarge
Page 2

always be used under supervision. Fil- ters that are saturated with grease can pose a fire hazard! Keep the extractor hood under constant supervision when deep-frying! Remember to clean out the filters regularly. Flambéing under the extractor hood is not allowed! Gas appli- ances may only be used under the ex- tractor hood with saucepans placed over them! If you are using more than three gas rings at the same time, operate the extractor hood at power level "2" or higher. This prevents the build-up of heat in the appliance. Preparing for use The extractor hood model complies with the relevant safety regulations for kitchen appliances in private house- holds. The requirements regarding the installation location are described in the user documentation supplied with the appliance. If you have any doubts as to whether your intended installation loca- tion meets the requirements, please contact our service department. Dam- aged appliances may not be put into operation. Defective parts must be re- placed with genuine spare parts or parts specified by GUTMANN. Repairs should only be carried out by authorised techni- cal staff. Activated carbon filter For activated carbon filters fitted in GUTMANN extractor hoods (C Version), please read the separate operating in- structions provided! Transport, unpacking, installation Condensation may occur if the appli- ance is brought into the installation site from a cold environment. Please wait until the appliance has adjusted to the temperature and is completely dry be- fore operating it. The acclimatization period depends on the temperature dif- ference and the type and design of the appliance. However, it should be at least 12 hours. Connecting the power supply Check that the rated voltage indicated on the appliance matches the mains voltage in your area. Connection to the incorrect voltage will damage or destroy the appliance. Before switching on the appliance, check that all cables and lines are properly fitted and undamaged. Make sure in particular that there are no kinks in the cables, that they are not pulled too tightly around corners and

Safety information These operating and installation instruc- tions contain important information that must be observed to ensure safe and reliable operation of the extractor hood. Please store them in a safe place for future reference. These operating in- structions refer to several versions of the appliance. They may contain de- scriptions of certain features not found on your model. The extractor hood must not be used by persons (incl. children) with impaired physical or mental capa- bilities or persons who lack experience and/or knowledge of how to use it. Chil- dren must be supervised to ensure that they do not play with the appliance. Intended use The extractor hood may only be used to extract kitchen vapours above the cook- ing appliances in private households. Any other use will be deemed to be im- proper. Improper use of the hood may pose a danger to persons and objects. The extractor hood must not be used as a shelf to store objects such as bottles, spice jars or other loose objects. Installation The appliance may only be installed and connected by an authorised technician observing all relevant regulations of the electric utility companies and the appli- cable building regulations. During instal- lation, observe the relevant instructions! Damaged appliances may not be put into operation. Defective parts must be replaced with genuine parts. Repairs should only be carried out by authorised technical staff. Danger of intoxication! If the extractor hood is operated in ex- traction mode at the same time as other room-air-dependent fire appliances (e.g. wood, gas, oil or coal-fired appliances) in the same room, lethal combustion gases may be directed back into the room due to the resulting negative pres- sure. For this reason, you must ensure a sufficient air supply at all times! The negative pressure in the room must not exceed 4 Pa (0.04mbar). Fire hazard! The extractor hood must never be oper- ated without the grease filter and must

Page 3 of the Gutmann Capa user manual — Instruction Manual
Page 3 · click to enlarge
Page 3

that no objects are resting on them. Also make sure that all plug connections are securely inserted. Faulty shielding or wiring poses a health hazard (electric shock) and can destroy other appli- ances. Appliances with mains plugs are fitted with a safety-tested mains cable for the respective country of use and may only be connected to a correctly earthed safety socket. Otherwise, there is a risk of electric shock. Make sure that the socket on the appliance or the domestic safety socket is easily accessi- ble so that the mains cable can be un- plugged from the socket in an emer- gency or during servicing and mainte- nance work. Danger of electric shock! Do not clean the hood with a steam cleaner or water pressure cleaner. The hood must be disconnected from the power supply prior to cleaning.

Gutmann Capa — Instruction Manual diagram (page 3)
Fig. 1 · Instruction Manual

Instruction Manual

The functions of the hood as well as the power level of the external motor can be controlled in two different ways:

General Function: The extractor hood was developed spe- cifically for extraction of cooking vapours in private homes. The rising cooking vapours are caught by the extractor hood and extracted via metal filters. The metal filters are inserted flush at the centre of a dark glass panel for optical reasons; they are held in the hood body with magnets. The resulting extraction is centrally guided over the metal filters. It is highly efficient. Accessibility of the metal filters is ensured without any prob- lems from the bottom of the hood. com- bined with glass elements. The extrac- tion performance is controlled via the control panel. For some hoods, the con- trol panel controls not only the lighting, but also additional functions. Cooking hob lighting is provided by several halo- gen spots aligned behind a glass pane. For hygienic reasons, the extractor hood is made from stainless steel Product description

1. Operation via remote control (recommended) 2. Operation via switch Operation via Remote Control
Gutmann Capa — Instruction Manual diagram (page 3)
Fig. 2 · Instruction Manual

1 Upper hood 2 Lower hood 3 Metal filter 4 Recirculation opening 5 Halogen lighting 6 Glass front, at the bottom of the hood

ON/OFF To switch on, press the field with the ON/OFF symbol. The fan runs at the 3. level. To switch off, press the ON/OFF symbol again.

Page 4 of the Gutmann Capa user manual — - +
Page 4 · click to enlarge
Page 4

Increasing fan power Press the symbol Increase fan power. The fan power is increased by one level each time the field is pressed.

Technical data

Dimensions: 230 x 34 x 10 Battery: 2 lithium batteries Type: CR 2032 3 V Infrared range: max. 5 m Operation via Switch

Reducing fan power. Press the symbol Reduce fan power. The fan power is reduced by one level each time the field is pressed until level 1 is reached.

Gutmann Capa — Technical data diagram (page 4)
Fig. 3 · Technical data
Gutmann Capa — Technical data diagram (page 4)
Fig. 4 · Technical data

Lighting Press the button with the lighting symbol to switch on the lighting. The lighting is switched off by pressing the button again. The lighting is dimmed by press- ing and holding the lighting symbol.

Gutmann Capa — Technical data diagram (page 4)
Fig. 5 · Technical data

- +

Intensive level Maximum fan power is reached by pressing the button Intensive level. The fan power switches back by one level after 5 minutes.

Pressing the switch to the left: Light ON/ OFF

Pressing the switch to the right: Regula- tion of the power level

Automatic follow-up time The automatic follow-up time is acti- vated by pressing the field with the Fol- low-up time symbol (2nd symbol from the left). The follow-up time symbol lights up. The extractor hood switches from level 3 back top level 1 and runs at this level ~15 minutes before switching off.

Pressing the switch to the right for 3 seconds: hood is turned off.

The filter saturation display is also reset using this switch. To do so, press the switch to the right until the red LED turns off. LED Indicators

Information regarding the operating con- ditions of the hood can be read on the device’s LED indicators:

Changing the batteries: The battery cover is situated on the back of the remote control. Lift the cover with thumb and first finger until the mag- netic contact that holds the battery cover releases. Now remove the empty batter- ies and replace them with new batteries of the same type. Caution: Do not dis- pose of empty batteries with your nor- mal household waste!

Gutmann Capa — - + diagram (page 4)
Fig. 6
Gutmann Capa — - + diagram (page 4)
Fig. 7
LED 1Indicates operational status ON/ OFF

LED 1 blinking: Indicates automatic cool down period (the hood will automatically decrease by one power level every 5 minutes until it finally turns off)

Page 5 of the Gutmann Capa user manual — Cleaning and care
Page 5 · click to enlarge
Page 5
LED 2Power level 1 (lowest motor speed), press button 2 on the remote control once

Cleaning and care instructions When cleaning the grease filters, also remove any grease deposits from the accessible housing components. This will prevent a fire hazard and maintain an optimum range of functions. Use hot soapy water or a mild window cleaning agent to clean the hood. Do not scratch off baked-on deposits. Soften them us- ing a damp cloth. Do not use abrasive agents or scouring pads.

LED 3Power level 2 (middle motor speed)

Press button 2 on the remote control twice

LED 4Power level 3 (high motor speed)

Press button 2 on the remote control three times

LED 5Intensive level (motor automatically returns to level 3 after 3 minutes)

Press button 3 on the remote control

Only clean the operating panel with a soft damp cloth (mild detergent solu- tion). Do not use stainless steel cleaners for the sliding switch/pressure switch.

LED 6Filter Saturation Indicator

The metal filter must be cleaned when the red LED lights up (see section on cleaning and care).

Stainless steel surfaces: Use a mild and non-abrasive stainless steel cleaning agent. Do not clean stainless steel surfaces with abrasive scouring pads or with cleaning agents containing sand, soda, acid or chloride! Clean in direction of polish only. We recommend our stainless steel cleaner no. 461731. See the enclosed service booklet for the order address.

Cleaning and care

Aluminium, varnished and plastic surfaces: Use a soft micro fibre cloth. Do not use dry cloths. Use a mild window-cleaning agent. Do not use aggressive cleaning agents or agents containing acid or lye! Do not use scouring agents.

Regular cleaning of the surface saves laborious removal of stubborn contami- nation. Only use conventional deter- gents or universal cleaning agents suit- able for cleaning stainless steel/ aluminium. Never use abrasive cleaning agents or steel wool. After cleaning the hood, treat the stainless steel surfaces with a stainless steel care product.

Metal filter Removing the filters Fire hazard! The performance of the extractor hood is reduced by grease

Painted surfaces should only be cleaned using a mild detergent solution and a very soft cloth. Only use a soft damp cloth to clean the operating panel.

Gutmann Capa — Cleaning and care diagram (page 5)
Fig. 8 · Cleaning and care

On hoods fitted with a panel below the filter (edge extraction), grease deposits occur at the edge of the panel. These deposits occur for physical reasons and are not due to a malfunction of the hood. Please clean the panel underneath the filter regularly to prevent the formation of stubborn residues.

Cleaning the surfaces

Page 6 of the Gutmann Capa user manual — Cleaning and care
Page 6 · click to enlarge
Page 6
Gutmann Capa — Cleaning and care diagram (page 6)
Fig. 9 · Cleaning and care
Gutmann Capa — Cleaning and care diagram (page 6)
Fig. 10 · Cleaning and care

swivelled down. Turn out the two screws at the upper body of the hood and se- cure the lower body of the hood with one hand. After removing the two screws, swivel down the lower body of the hood slowly. The activated carbon filters are kept in the upper hood body with toggle locks. For replacement, loosen the toggle locks and remove the activated carbon filters diagonally down- wards. Installation is performed in re- verse order. Important: The activated carbon filter must not be cleaned wet. See sep. instructions "activated carbon".

residues and the fire hazard increases. To prevent a fire hazard, you must clean the filters regularly. The grease filters must be cleaned at the least once a fortnight. To do this, grip the metal filter with both hands at the top and bottom and pull forward until the magnet con- tact releases. You can now remove the metal filter. Installation in reverse order.

Cleaning the filters The stainless steel filter is best cleaned in the dishwasher or with a mild dish- washing agent. The manufacturer ac- cepts no liability whatsoever for any discolouration caused by the use of ag- gressive dishwashing agents. Tempera- tures exceeding 65 degrees Celsius must be avoided.

Lighting replacement (C-Version) Defective luminaires must be replaced without delay. Before exchanging the luminaires, power down the extractor

Gutmann Capa — Cleaning and care diagram (page 6)
Fig. 11 · Cleaning and care

Replacing activated carbon filter (only for hoods with recirculation, C-Version) The activated carbon filters bind odours in kitchen vapour. Depending on strain, these filters must be replaced or regen- erated after no more than 6 months. The activated carbon filter is installed in a frame to the left and right of the ventila- tion module in the upper hood body. To replace it, the metal filters must be taken out and the hood swivelled down (on this, see section "Replacing the metal filter" + "Lighting replacement"). For this, the lower body of the hood must be

Gutmann Capa — Cleaning and care diagram (page 6)
Fig. 12 · Cleaning and care
Page 7 of the Gutmann Capa user manual — Cleaning and care
Page 7 · click to enlarge
Page 7

hood! The lamps will remain hot for some time. Please wait until they have cooled down before replacing them. After cooling down, the hood body must be swivelled out. For this, turn out the two screws in the upper body of the hood and secure the lower hood body with one hand. After removal of the two screws, swivel the lower part of the hood down slowly. The luminaires are now easily accessible and can be re-

Faults Please contact our service department immediately, if: - If the extractor hood creates unusual noises and you are unable to detect any faults after checking the extraction air line - If you discover, for example, by hear- ing strange noises, that the motor is faulty or defective - the switches are not working properly. Please remember to indicate your ex- tractor hood model and the correspond- ing serial number. This information can be found on the type plate. This plate is located inside the hood near the filters. Disposal

Gutmann Capa — Cleaning and care diagram (page 7)
Fig. 13 · Cleaning and care

Packaging The packaging for the extractor hood is recyclable. Cardboard and polyethylene film (PE) are used as packaging materi- als. These materials must be disposed of in an environmentally compatible manner in accordance with local regula- tions. Extractor hood Your local authority will also be happy to advise you on the environmentally sound disposal of old household appli- ances. Environmental information All models manufactured by GUTMANN are identified in accordance with Euro- pean Directive 2002/96/EC on waste electrical and electronic equipment (WEEE). This directive specifies the framework for the EU-wide return and disposal of used appliances. Please ask your dealer for information about current disposal methods. We reserve the right to make technical changes. Technical data Connection mains: 230 V / 50 Hz, max. 500 Watt Lighting: Halogen cold light 12V 28Watt

placed. For this, first remove the socket (a) from the luminaire (c). Then com- press the spring ring (b) and take it out upwards. The luminaire can now be removed from the covering rosette (d) and replaced. Attention: the covering rosette is glued in and cannot be re- moved! When inserting the new lumi- naire, always prevent skin contact. Pro- ceed in reverse order for installation. Attention: The hood body cannot be swivelled down in the B or A versions! In these versions, the luminaires are ac- cessible through the filter space and are removed in the same order.

Ask about the Gutmann Capa

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Gutmann Capa

Be the first to ask — other owners or our team will answer.

Original document