Version 4.30
Installation Manual
Issue C





Hereby Guardall declares that the RX16i, QX32i, PX48i and the PX80i are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. If you have any doubts concerning the suitability, connection or uses of this apparatus then consult a suitably qualified person before continuing. SUITABILITY FOR USE The apparatus has been designed to work on all European analogue networks and has been independently tested to TBR21. It provides the following facilities: 1. Alarm transmission and transmission/reception of configuration data. 2. Automatic Call Initiation. 3. Series connection. 4. Dial tone Detection 5. Automatic dialling using DTMF tones. 6. Automatic Call Answering. 7. Stored number dialling. 8. Timed Break Register Recall. It is not suitable for connection to PABX systems or for use as an extension to a payphone. EN50131 & PD6662 Compliance
PX, QX and RX are suitable for use in systems designed to comply with PD6662:2004. The grade and class of each variant is shown in the table.
Variant Grade Class RX16i/QX32i 2 II All PX 2 or 3 (Programmable) II Refer to the reset options in the engineer programming manual for details on programming the EN grade.



The installation manual provides the information essential for wiring and operating the system. A full engineer manual (part number W76232) is available from Guardall. Copies of the engineer manual, and all other Guardall manuals, can be downloaded from the Guardall web site at,
www.guardall.co.uk The documentation section of the Guardall web site is password protected, and you may have to apply for access using the on-line form provided on the site. Alternatively a printed copy of the manual may be obtained by sending a FAX or letter to our Customer Helpline, requesting the full Engineering Manual.

Edinburgh EH28 8PL This manual and the PX/QX/RX systems described in it are copyrighted, with all rights reserved. This manual may not be copied except as expressly permitted in writing by Guardall Limited. Export of this technology may be controlled by the U.S. Government. Diversion contrary to U.S. Law prohibited.

In this manual you will learn how to;
+ Red - Black A Yellow B Blue • Set the address of the concentrator to address 1 (DIL switches 1-6 all off (0))

Getting Started

Once the keypad is replying then enter the default engineer PIN code, 9999, remembering to validate the PIN code by pressing .

The PIN code digits are displayed as “*” characters.
As the system uses hazardous voltages it is recommended that the mains supply connection follow national wiring rules and is carried out by a suitably qualified person. This equipment must be permanently connected to a mains fused spur (3A or 5A). The mains cable should be clamped securely with the cable clamps provided within the equipment/installation kit. Knockouts are provided on the top, bottom and sides of this equipment and these are intended for conduit or cable glands. As a mains switch is not provided on the equipment, a readily accessible disconnect device shall be incorporated in the building installation wiring. Where there is doubt as to the phase of this wiring , the device, when operated, will disconnect both poles simultaneously. Mains Supply

The DC supply output is a Safety Extra-Low Voltage (SELV) circuit. This DC supply rating is for all the DC current requirements, including recharging the battery. The supply has the following rating:

All wiring in this enclosure requires to be V-2, IEC approved or PVC type. All installation wiring within this equipment should utilise plastic cable ties to bundle cables so as to provide strain relief for the cable.

Order Codes

A system comprises of the following components: 1. A control unit, which processes all the alarm information from the detection points. Outputs are provided to operate sounders, strobe and communication devices. Configuration information is stored in EEPROM. The manual details the features of the control panels. Most features in the PX panel range are common. The differences are shown in the table.
Feature RX16i QX32i PX48i PX80i PX500 PX250HS Max. Circuits 16 32 48 80 512 256 Max Concentrators 2 6 10 18 64 32 Circuit Doubling SDIs 8 8 8 16 32 32 Max. Panel Users 16 32 50 100 200 200 Max. Access Users 1000 Areas 4 8 8 16 32 16 Set Groups 8 8 16 32 16 Sub systems 4 4 8 16 8 Max Keypads 4 8 8 16 32 16 Output Modules 1 2 8 16 32 32 Output functions 16 16 20 64 128 128 Serial/Data comms Modules
2
Access Modules 32 Audio Modules 2 4 8 16 32 16 Radio Modules 1 2 4 8 16 8 Max. Transmitters 16 16 24 40 128 128 Video cameras 4 8 32 Responses 2 5 5 10 20 20 Tel Numbers 8 GSR profiles 1 2 4 Schedules 2 4 32 Holidays 14 20 Event Log Size 250 500 1000 1000 1000 2000 Access Log Size 1000 The diagram on the following page shows the bus peripheral connections. 2. User interaction with the system is via LCD keypad. There must be at least 1 keypad on a system. There are several types of LCD keypad available, which are detailed later. 3. On the RX16i, QX32i, PX48i and PX80i, up to 8 detectors may be connected directly to the panel. Further detectors, up to the control panel limit, may be connected to the system through concentrators on a 4-wire bus. Each concentrator provides 8 additional circuits. 4. Optional equipment includes;
System Components


RX16i - 6 TX outputs QX32i - 6 TX outputs
Up to 3 external


LF


PX500
2 8TX
PX 34


Parameter Range Temperature range -10 to 50 °C Humidity 10% to 90% relative humidity Technical Specification Cable Type
The system has a 4-wire bus for all peripherals. The recommended cable type is 7-strand/0.2mm2 diameter un-screened cable, which has a resistance of 90 ohms/km and a core to core capacitance of 85nF/km. The screened cable referred to in this manual has a capacitance of 68nF/km and a resistance of 39R/km. If screened cable is used it should be terminated in the control panel and connected to earth. Refer to the section on user interfaces and concentrators for details of the maximum length of cable on each bus. Technical Specification Cable Length
The maximum length, with a single standard keypad connected at the end of the cable and no other peripherals connected on the data bus, is shown in the table.

Maximum Data Bus Cable Length (m) Power Source Un-screened Cable Screened Cable Control Panel 600m 1900m Local Aux. PSU, with single 0v core
If auxiliary PSUs are used then all 0v connections must be connected to the control panel 0-volt terminal. It is not recommended practice to share a sensor connection and the data bus connections in the same cable. Technical Specification Operation Voltage
The operating voltage range of all XiB components is shown in the table.
Parameter Minimum Typical Maximum Voltage (volts) 10.5 v 13.5 v 15 v

Voltage (Volts) Condition > 11.7 Battery OK 11.4 Low Volts 10.7 Power Fail < 10.6 Deep discharge

Technical Specification Current Consumption
Product Current (mA) RX16i/QX32i 76 PX48i/PX80i 85 PX500/PX250HS 80 Keypad (standard) 28 Keypad with proximity 85 Mini keypad 80 Concentrator (8-input) 42 Concentrator (4-input) 25 3A Smart Concentrator 100 Output module 22 (all relays off) Serial module 30 Access module 33 Proximity Reader 14 Bus isolator 25 Data comms Module 60 GSM/Dual Comm module 60 (standby) 125 (transmitting, strong signal present) 180 (transmitting, weak signal present) PSTN module 50 Audio Bus Interface Standby-6 Listen-6 Talk-10 Audio Bus Interface/Speech & Record
Standby-11 Playback-23 Record-32 TalkBack Module Standby-26 Listen-41 Talk-62 Microphone Module Standby-26 Listen-41 Microphone Standby-5 Listen-15 Speech module Standby-11 Playback-23 Record-32 Radio Module (Inovonics) 75 Radio Module (Visonic) 52 Technical Specification Battery Standby
The following example shows the average system current (excluding sensors) for a typical system at a supply voltage of 14 volts.

PX500/ PX250HS Panel 76 85 80 1 Keypad 28 28 28 1 Concentrator 42 42 42 Total (mA) 146 155 150 The table below shows the available auxiliary current for various battery sizes using the above typical system current.

The power supply standby capacity specified in PD6662:2004 is shown in the table.
Grade 1 2 3 4 Standby time (hours) 12 12 24 24 The following tables show the maximum available system current with a minimum of 12 hours standby for each combination of power supply and battery size.
RX16i/QX32i (with 1A PSU) 24 hour battery re-charge time with a minimum 12 hours standby Battery Size Maximum recharge
Available Current (For sensors etc.)
7 Ah 500mA 500mA 14 hours 146mA 354mA
PX48i/PX80i (with 1.5A PSU) 24 hour battery re-charge time with a minimum 12 hours standby Battery Size Maximum recharge
Available Current (For sensors etc.)
7 Ah 750mA 580mA1 12 hours 155mA 425mA 12 Ah2 750mA 750mA 16 hours 155mA 595mA 17 Ah 750mA 750mA 22 hours 155mA 595mA 18 Ah 750mA 750mA 24 hours 155mA 595mA
PX500/PX250HS 24 hour battery re-charge time with a minimum 12 hours standby Battery Size Maximum recharge
Available Current (For sensors etc.) 7 Ah 780mA 580mA1 12 hours 150mA 430mA 12 Ah 780mA 1A1 12 hours 150mA 850mA 17 Ah 780mA 1.41A1 12 hours 150mA 1.26A 18 Ah 780mA 750mA1 24 hours 160mA 590mA
PX 500 current (example system)
1 Note that the maximum system current has been de-rated to provide the necessary standby capacity.

Technical Specification EOL Resistor Connections
Type 1 EOL Network (Guardall) Type 2 EOL Network
The EOL resistors are fitted in the detector as shown. This wiring arrangement applies to all EOL inputs in the system. Note: The diagram shows the default values of 8k2//8k2. The EOL resistor value can be programmed (Refer to the system options for details.).
R1
R2
PX
EOL Network with Fault
The EOL resistors are fitted in the detector as shown. Note that the Guardall V12-AM detector has the necessary 3 EOL resistors fitted on board. For full information refer to the V12- AM manual. A fault EOL resistor may only be used if the system is programmed to use the standard Guardall resistor network.
Aux.
The resistance for each possible state is shown in the table and can be displayed using the circuit check mode function.

Circuit State Nominal Resistance Tamper 0k Clear 4k1 Alarm 8k2 Aux (Fault) 12k3 Aux+Alarm (Mask)


The accuracy of the diagnostic system is typically less than 1%, with a maximum error 2.5%. This accuracy can only be achieved by programming the correct value of the 5V-reference voltage (option 69 on the main menu). Diagnostics Supply Measurements

Parameter Range Resolution Panel voltage 0-20v 78mV Panel battery voltage 0-20v 78mV System current 0-2A 7.8mA Battery Current 0-1.1A 4.4mA Battery standby capacity See Note 1 hour Concentrator current 0-250mA 1mA Concentrator voltage 0-15V 58mV Keypad voltage 0-15V 58mV Circuit resistance (for 8k2 EOL) 0-20K 70R Note: The displayed standby capacity will depend on the programmed battery size and the actual system current. Diagnostics XiB Comms LED
All XiB peripherals, except the keypad, have a green LED fitted, which is used to indicate the state of the XiB communications.

State Meaning OFF No power ON Communication error Slow FLASH Operating normally Quick FLASH Resetting, or frequency of polling in a dialler, serial module or IP module Diagnostics Circuit Limits
Pulse count 0 (Off) 0-255 0-255 Not Applicable Not
2 secs 2-255 seconds 2-255 seconds Not Applicable Not Applicable Tamper resistor
Alarm resistor 8k2 Programmable Programmable 8k2 8k2 Alarm/Tamper threshold
All percentages are with reference to the nominal programmed EOL value. The alarm and tamper EOL resistors are programmable. Refer to system options in the engineer manual for details.

Battery (max. 7 Ah)

Visonic internal receiver interface. Note that if a receiver is connected then the on board serial port cannot be used.
RX16i/QX32i Control Unit · line Telephone


+ STB SPK - R COM NC NO RTN CF LF + - + - + - A B
TB B Earth A TA 1 C 2 3 C 4 5 C 6 7 C 8 TX1 TX2 TX3 TX4 TX5 TX6 TX7 TX8OP1 OP2

PX 80/500/HS Control Unit Installation
The PX 500 control panel is supplied with a spares bag containing the following items:
Mark the fixing positions shown and secure the rear case to the wall using 3 suitable screws. There are 2 x 20mm conduit knockout positions as indicated. The required cable entry point(s) should be knocked out from the inside prior to mounting the case. There are 4 trunking knockouts. These can be knocked out from either side. Conduit knockout Trunking knockouts STU or XiB peripheral Battery

Fixing holes Trunking knockout Off the wall tamper SmartDial or XiB peripheral Conduit knockout Trunking knockout
PX500/PX250HS Control Unit

PX500/PX250HS PCB Connections (PX500/PX250HS)
All PCB connections are plug-on screw down terminal blocks. The function and position of each terminal is described in the following page.

LK6: Fit link for 10s to default the configuration.
LK4: Connect thermistor cable and place thermistor on the battery.
Connect comm fail and line fault to v+ to disable
LK5: Battery disconnect disable. Fit link to power-up on battery.

Outputs 3&4 of 4-output concentrator may only be programmed on a contol panel fitted with version 3.10 or later.
6 5 4 3 2 1 1 0 2 0 1 3 0 1 0 4 0 1 1 5 0 0 0 1 0 0 6 0 0 0 1 0 1 7 0 0 0 1 1 0 8 0 0 0 1 1 1 9 0 0 1 0 0 0 10 0 0 1 0 0 1 11 0 0 1 0 1 0 12 0 0 1 0 1 1 13 0 0 1 1 0 0 14 0 0 1 1 0 1 15 0 0 1 1 1 0 16 0 0 17 0 1 0 18 0 1 0 0 0 1 19 0 1 0 0 1 0 20 0 1 0 0 1 1 21 0 1 0 1 0 0 22 0 1 0 1 0 1 23 0 1 0 1 1 0 24 0 1 0 1 1 1 25 0 1 1 0 0 0 26 0 1 1 0 0 1 27 0 1 1 0 1 0 28 0 1 1 0 1 1 29 0 1 1 1 0 0 30 0 1 1 1 0 1 31 0 1 0 32 0 1 33 1 0 34 1 0 1 35 1 0 0 0 1 0 36 1 0 0 0 1 1 37 1 0 0 1 0 0 38 1 0 0 1 0 1 39 1 0 0 1 1 0 40 1 0 0 1 1 1 41 1 0 1 0 0 0 42 1 0 1 0 0 1 43 1 0 1 0 1 0 44 1 0 1 0 1 1 45 1 0 1 1 0 0 46 1 0 1 1 0 1 47 1 0 1 1 1 0 48 1 0 1 49 1 1 0 50 1 1 0 0 0 1 51 1 1 0 0 1 0 52 1 1 0 0 1 1 53 1 1 0 1 0 0 54 1 1 0 1 0 1 55 1 1 0 1 1 0 56 1 1 0 1 1 1 57 1 1 1 0 0 0 58 1 1 1 0 0 1 59 1 1 1 0 1 0 60 1 1 1 0 1 1 61 0 0 62 1 0 1 63 1 0 64 1
PC1071A ADDRESS
8K2
8K2 ALARM
ALARM
Outputs 1-4 current limited to 250 mA
8K2
250 mA 250 mA
OP3
OP2
OP1
Case OTW Tamper Disable
FS 2
Connect to control panel XiB bus

All 4 circuit inputs are fast inputs and can be programmed to allow a direct connection of an inertia sensor (refer to the engineer manual for details.)
7 6 5 4 3 2 1 1 0 2 0 1 3 0 1 0 4 0 1 1 5 0 1 0 0 6 0 1 0 1 7 0 1 1 0 8 0 1 1 1 9 0 0 0 1 0 0 0 10 1 0 0 1 11 0 0 0 1 0 1 0 12 0 0 0 1 0 1 1 13 0 0 0 1 1 0 0 14 0 0 0 1 1 0 1 15 0 0 0 1 1 1 0 16 0 0 0 17 0 0 1 0 18 0 0 1 0 0 0 1 19 0 0 1 0 0 1 0 20 0 0 1 0 0 1 1 21 0 0 1 0 1 0 0 22 0 0 1 0 1 0 1 23 0 0 1 0 1 1 0 24 0 0 1 0 1 1 1 25 0 0 1 1 0 0 0 26 0 0 1 1 0 0 1 27 0 0 1 1 0 1 0 28 0 0 1 1 0 1 1 29 0 0 1 1 1 0 0 30 0 0 1 1 1 0 1 31 0 0 1 0 32 0 0 1 33 0 1 0 34 0 1 0 1 35 0 1 0 0 0 1 0 36 0 1 0 0 0 1 1 37 0 1 0 0 1 0 0 38 0 1 0 0 1 0 1 39 0 1 0 0 1 1 0 40 0 1 0 0 1 1 1 41 0 1 0 1 0 0 0 42 0 1 0 1 0 0 1 43 0 1 0 1 0 1 0 44 0 1 0 1 0 1 1 45 0 1 0 1 1 0 0 46 0 1 0 1 1 0 1 47 0 1 0 1 1 1 0 48 0 1 0 1 49 0 1 1 0 50 0 1 1 0 0 0 1 51 0 1 1 0 0 1 0 52 0 1 1 0 0 1 1 53 0 1 1 0 1 0 0 54 0 1 1 0 1 0 1 55 0 1 1 0 1 1 0 56 0 1 1 0 1 1 1 57 0 1 1 1 0 0 0 58 0 1 1 1 0 0 1 59 0 1 1 1 0 1 0 60 0 1 1 1 0 1 1 61 0 1 0 0 62 0 1 0 1 63 0 1 0 64 0 1
7 6 5 4 3 2 1 65 1 0 66 1 0 1 67 1 0 1 0 68 1 0 1 1 69 1 0 0 0 1 0 0 70 1 0 0 0 1 0 1 71 1 0 0 0 1 1 0 72 1 0 0 0 1 1 1 73 1 0 0 1 0 0 0 74 1 0 0 1 0 0 1 75 1 0 0 1 0 1 0 76 1 0 0 1 0 1 1 77 1 0 0 1 1 0 0 78 1 0 0 1 1 0 1 79 1 0 0 1 1 1 0 80 1 0 0 1 81 1 0 1 0 82 1 0 1 0 0 0 1 83 1 0 1 0 0 1 0 84 1 0 1 0 0 1 1 85 1 0 1 0 1 0 0 86 1 0 1 0 1 0 1 87 1 0 1 0 1 1 0 88 1 0 1 0 1 1 1 89 1 0 1 1 0 0 0 90 1 0 1 1 0 0 1 91 1 0 1 1 0 1 0 92 1 0 1 1 0 1 1 93 1 0 1 1 1 0 0 94 1 0 1 1 1 0 1 95 1 0 1 0 96 1 0 1 97 1 1 0 98 1 1 0 1 99 1 1 0 0 0 1 0 100 1 1 0 0 0 1 1 101 1 1 0 0 1 0 0 102 1 1 0 0 1 0 1 103 1 1 0 0 1 1 0 104 1 1 0 0 105 1 1 0 1 0 0 0 106 1 1 0 1 0 0 1 107 1 1 0 1 0 1 0 108 1 1 0 1 0 1 1 109 1 1 0 1 1 0 0 110 1 1 0 1 1 0 1 111 1 1 0 1 1 1 0 112 1 1 0 113 1 1 1 0 114 1 1 1 0 0 0 1 115 1 1 1 0 0 1 0 116 1 1 1 0 0 1 1 117 1 1 1 0 1 0 0 118 1 1 1 0 1 0 1 119 1 1 1 0 1 1 0 120 1 1 1 0 121 0 0 0 122 1 0 0 1 123 1 0 1 0 124 1 0 1 1 125 1 0 0 126 1 0 1 127 1 0 128 1
ON
OFF
8K2
ADDRESS
8K2 ALARM
DIL SW8 ON = Tamper disable
8K2
8K2
Outputs 1 &2 current limited to 250 mA
OP1

The 3A Smart concentrator can be used with a single battery or 2 batteries. If 2 batteries are used they should be of the same type and capacity. If a single battery is used it should be connected to the Batt 1 terminals. The case can accommodate 7Ah or 18Ah batteries. Deep discharge protection is provided for each battery.
Mains block F630mA 230v supply FS1 F1.6A Aux. 1 DC output (monitored)
FS2 F1.6A Aux. 2 DC output (monitored)
LK5 fiited 2A aux current/1A battery charge current LK5 not fitted 1.5A aux current/1.5A battery charge current LK8 External tamper disable
6 5 4 3 2 1 1 0 2 0 1 3 0 1 0 4 0 1 1 5 0 0 0 1 0 0 6 0 0 0 1 0 1 7 0 0 0 1 1 0 8 0 0 0 1 1 1 9 0 0 1 0 0 0 10 0 0 1 0 0 1 11 0 0 1 0 1 0 12 0 0 1 0 1 1 13 0 0 1 1 0 0 14 0 0 1 1 0 1 15 0 0 1 1 1 0 16 0 0 17 0 1 0 18 0 1 0 0 0 1 19 0 1 0 0 1 0 20 0 1 0 0 1 1 21 0 1 0 1 0 0 22 0 1 0 1 0 1 23 0 1 0 1 1 0 24 0 1 0 1 1 1 25 0 1 1 0 0 0 26 0 1 1 0 0 1 27 0 1 1 0 1 0 28 0 1 1 0 1 1 29 0 1 1 1 0 0 30 0 1 1 1 0 1 31 0 1 0 32 0 1 33 1 0 34 1 0 1 35 1 0 0 0 1 0 36 1 0 0 0 1 1 37 1 0 0 1 0 0 38 1 0 0 1 0 1 39 1 0 0 1 1 0 40 1 0 0 1 1 1 41 1 0 1 0 0 0 42 1 0 1 0 0 1 43 1 0 1 0 1 0 44 1 0 1 0 1 1 45 1 0 1 1 0 0 46 1 0 1 1 0 1 47 1 0 1 1 1 0 48 1 0 1 49 1 1 0 50 1 1 0 0 0 1 51 1 1 0 0 1 0 52 1 1 0 0 1 1 53 1 1 0 1 0 0 54 1 1 0 1 0 1 55 1 1 0 1 1 0 56 1 1 0 1 1 1 57 1 1 1 0 0 0 58 1 1 1 0 0 1 59 1 1 1 0 1 0 60 1 1 1 0 1 1 61 0 0 62 1 0 1 63 1 0 64 1
LK3 Batttery 1 deep discharge relay bypass
LK4 Batttery 2 deep discharge relay bypass
FS6 F2.5A Overvoltage protection
Link 4 Link 3
FS3 F2.5A Battery 1
FS4 F2.5A Battery 2
FS5 F800mA XiB out
LK1 Connect 0v to earth
LK9 Case tamper disable
FSx(2.5A)
Battery 1 (7 or 18 Ah)
+ - + -
Charge voltage 13.7v+/-2%, temp. compensated
Battery 2 (7 or 18 Ah)
circuits 1-10. Link 5
+ - + -
14v +/-5%, 2A/1.5A max. (Refer to LK5)
- + + -
XiB bus in (from
ADDRESS
number. By default, inputs 1-10 are mapped to
switched off. There is no requirement to
terminate the input with the EOL resistors.
Each input can be mapped to any circuit
If an input is not used the circuit can be
Cct 5 Cct 6
OP4
OP3
OP2
OP1
OTW
(Ext.

The 3A Smart Concentrator has 2 XiB connectors, XiB in and XiB out. The XiB in connector must be used to connect the XiB bus from the panel. All 4 wires may be connected but the XiB in + terminal is not connected to the XiB out + terminal. The XiB out connector is used to connect all XiB peripherals that are to be powered from the 3A Smart Concentrator. The XiB out bus is electrically isolated from the XiB in bus and peripherals can be connected on the XiB out bus up to 1.7km from the 3A Smart concentrator (at 9k6 baud).

XiB Busses


Refer to the relevant XiB Detector installation manual for the connection details PQ15 XiB Manual Part No: 321094 PQ15-AM XiB Manual Part No: 321097 DT15+ XiB Manual Part No: 321106 DT15-AM XiB Manual Part No: 321113
XiB Detectors


5 4 3 2 1 1 0 2 0 1 3 0 0 0 1 0 4 0 0 0 1 1 5 0 0 1 0 0 6 0 0 1 0 1 7 0 0 1 1 0 8 0 0 1 1 1 9 0 1 0 0 0 10 0 1 0 0 1 11 0 1 0 1 0 12 0 1 0 1 1 13 0 1 1 0 0 14 0 1 1 0 1 15 0 1 1 1 0 16 0 17 1 0 18 1 0 0 0 1 19 1 0 0 1 0 20 1 0 0 1 1 21 1 0 1 0 0 22 1 0 1 0 1 23 1 0 1 1 0 24 1 0 1 1 1 25 1 1 0 0 0 26 1 1 0 0 1 27 1 1 0 1 0 28 1 1 0 1 1 29 1 1 1 0 0 30 1 1 1 0 1 31 0 32 1

The 10k pull up is reduced to approximately 500R if a relay is fitted to the same output channel.
NC
NO
NC
NO
NC
NO
NC



RX V+ 0v TX Address DIL Switch 8 7 6 5 4 3 2 1 1 X 0 2 X 0 0 0 1
A serial module can be added at any time to a powered system but must be added to the system size before it will operate.

The function switches only apply to versions up to v3.20.
Function DIL Switch 8 7 6 5 Printer/PC 0 Printer 0 0 0 1 PC 0 0 1 0
The printer format is fixed at 1200 baud, no parity, 8 data bits and 1 stop bit. PC baud rate is 9600.
Serial Module · Engineer Keypad


Address DIL Switch 8 7 6 5 4 3 2 1 1 0 2 0 1
The data comms module address can be set to 1 or 2 only. If a serial module is connected to the system then the serial module and data comms module addresses must be unique.
Data Comms Module · Engineer · Keypad


To set the address, create a case tamper and the press and hold down the ? button for a few seconds. Enter the address number when prompted.

The mini LCD proximity keypad is supported from v4.20.
Mini Keypad

The XiB bus isolator can be used to both extend the maximum XiB cable length and to electrically isolate parts of the bus. The maximum bus extension will depend on the cable type and the supply voltage. Up to 2 bus isolators may be connected in series, giving a total bus length of 5.1km using standard un-screened cable. Refer to the Technical Specification section for the cable specification. Bus Isolator PCB Connections

XiB Bus In (from control
Bus Isolator · XiB Bus out · panel)

(2A)

Address DIL Switch 5 4 3 2 1 1 0 2 0 1 3 0 0 0 1 0 4 0 0 0 1 1 5 0 0 1 0 0 6 0 0 1 0 1 7 0 0 1 1 0 8 0 0 1 1 1 9 0 1 0 0 0 10 0 1 0 0 1 11 0 1 0 1 0 12 0 1 0 1 1 13 0 1 1 0 0 14 0 1 1 0 1 15 0 1 1 1 0 16 0 17 1 0 18 1 0 0 0 1 19 1 0 0 1 0 20 1 0 0 1 1 21 1 0 1 0 0 22 1 0 1 0 1 23 1 0 1 1 0 24 1 0 1 1 1 25 1 1 0 0 0 26 1 1 0 0 1 27 1 1 0 1 0 28 1 1 0 1 1 29 1 1 1 0 0 30 1 1 1 0 1 31 0 32 1

DIL SW 8 - Tamper Disable DIL SW7 - Default config DIL SW6 - Not used
To default the access module configuration power up with SW7 ON and return SW7 to the Off after a few seconds.
Door (N.C.)
Reader supply voltage - Select 12v for Guardall readers.
Access Module · Door Relay · AUX Relay


The Proximity Reader is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Whilst it operates on a non-harmonised frequency of 125KHz, it meets all relevant harmonised standards. It has been notified in the following EU countries: Belgium, Italy, France, The Netherlands, Denmark, Finland, UK, Ireland, Germany, Spain, Portugal, Norway, Greece and Sweden. Proximity Reader Access Module Connections


The diagram shows a Guardall reader. Other types of reader may be used. Refer to the engineer programming manual (System/card types) for details.
Black, 0 Volt
Brown, LED green
Green, LED red
Blue, DATA 1/Data
Black, 0 Volt
Brown, LED green
Green, LED red
Reader supply voltage - Select 12v for Guardall readers.
Blue, DATA 1/Data
Orange, DATA 0/Clock
Ground

Proximity Reader Keypad Connections

To Drive an LED directly from a keypad connect either the brown wire (Green LED) or the green wire (Red LED) to the OP terminal of the keypad. The keypad output can be programmed for set, entry/exit or any other output function.
The diagram shows a Guardall reader. Other types of reader may be used. Refer to the engineer programming manual (System/card types) for details.
It is not recommended practice to share a sensor connection and the data bus connections in the same cable.


Function Red LED Green LED Door LOCKED ON OFF Door UNLOCKED ON ON INVALID card, Access DENIED or Access ACCEPTED but door not opened.
ON ON (when door open and locked, flash on for 1 second) Access ACCEPTED, Area was in alarm
Door FORCED Alarm Flash ON Door TAMPER Alarm Flash ON Door area set OFF blink for 10 secs, then goes to Door Locked Door OPEN Alarm Start / Finish
Door area setting Slow flash on both LEDs Module logging data or undergoing configuration



Address DIL Switch 5 4 3 2 1 1 0 2 0 1 3 0 0 0 1 0 4 0 0 0 1 1 5 0 0 1 0 0 6 0 0 1 0 1 7 0 0 1 1 0 8 0 0 1 1 1 9 0 1 0 0 0 10 0 1 0 0 1 11 0 1 0 1 0 12 0 1 0 1 1 13 0 1 1 0 0 14 0 1 1 0 1 15 0 1 1 1 0 16 0 17 1 0 18 1 0 0 0 1 19 1 0 0 1 0 20 1 0 0 1 1 21 1 0 1 0 0 22 1 0 1 0 1 23 1 0 1 1 0 24 1 0 1 1 1 25 1 1 0 0 0 26 1 1 0 0 1 27 1 1 0 1 0 28 1 1 0 1 1 29 1 1 1 0 0 30 1 1 1 0 1 31 0 32 1
- IP3 + SW - IP2 + SW - IP1 + SW
Audio Module · Red Black · External microphone connections

Audio System Connecting an External Microphone
Up to 3 external microphones can be connected to each audio module. The sensitivity of each external microphones can be increased by fitting the appropriate link (MIC1, MIC2 or MIC3) on the audio module PCB.

- IP3 + SW - IP2 + SW - IP1 + SW
Audio System Connecting the Audio Bus Interface
The Audio Bus Interface (ABI) can be fitted, along with an Audio Module, to provide audio capability to the system. For systems requiring the ability to record and playback messages, a speech module is fitted in place of an ABI. Either board should be fitted with the power removed from the Control Panel. Power should only be restored after the alignment of the two boards has been checked.


The radio module is fitted with 2 PCBs; a RF module and a serial interface for connection to the control panel XiB bus. The serial interface PCB is multi-function and for operation as a radio interface DIL switches 6 and 8 must be on and DIL switch 7 off. DIL switches 1-5 are used to select the radio module address. The diagram shows the Inovonics receiver module (W76067). The Visonic radio module (W76110) internal layout is similar. Refer to the serial module section for the connection details. The radio module type must be programmed. Refer to the radio options in the engineer manual for more information.

DIL switches 6-8 are factory set to the radio module function
Function DIL Switch 8 7 6 Radio 1 0 1
A radio repeater(s) may be added to the system. Each radio repeater should be added as a transmitter (refer to the engineer manual for details).
Radio Module

Hereby Guardall, declares that the Dual comm module and PSTN module is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. If you have any doubts concerning the suitability, connection or uses of this apparatus then consult a suitably qualified person before continuing. SUITABILITY FOR USE The apparatus has been designed to work on all European analogue networks. It provides the following facilities: 1. Alarm transmission and transmission/reception of configuration data. 2. Automatic Call Initiation. 3. Series connection. 4. Dial tone Detection 5. Automatic dialling using DTMF tones. 6. Automatic Call Answering. 7. Stored number dialling. 8. Timed Break Register Recall. It is not suitable for connection to PABX systems or for use as an extension to a payphone. The Dual comm module and the GSM module are fitted with a GSM engine which has been declared compliant with the essential requirements of Directive 1995/05/EC by the manufacturer Dia telecom Spa (Telit). The conformity assessment procedure referred to in Article 10 and detailed in Annex IV of Directive 1999/05/EC was carried out by a Notified Body, namely BABT, Walton-on-Thames, UK (Notified body number 0168). The GSM engine complies with the following standards:
GSM/Dual Comm module · Statutory Requirements

The Dual Comm module, GSM module and the PSTN module may be used with any Guardall control panel.

Feature Implementation Transmission Voice and Data Frequency Band Dual Band EGSM900 and EGSM1800 Transmit Power Class 4 (2W) for EGSM 900MHz Class 1 (1W) for EGSM 1800MHz Data 9.6Kbps Supported SIM card 3V cards There are a number of important points to consider when using one of the new module types with an existing panel: 1. All previous communicators were designed for use within the panel case and consequently they were designed with no tamper switch. The GSM/Dual comm module is intended for use outside the panel case, and so needs a case tamper. The GSM/Dual comm module case tamper is recognised from panel v4. If the GSM/Dual comm module used with earlier panel versions it is recommended that line fault monitoring is enabled to act as a substitute for the tamper sensing. 2. The Dual comm module functions are programmed using the DIL switches. Future versions of the firmware will include additional menu options for GSM programmable functions. The version number of the first release of firmware is v4.50. This is necessary to enable older panel versions to recognise the module and allow access to the appropriate programming menus Installation
Special care is required when installing the GSM module or Dual Comm module; 1. Avoid placement on metal surfaces to ensure good radio performance. 2. To minimise GSM transmission interference, route all cables away from the GSM antenna. 3. If the system includes Audio Modules ensure that there is at least 3m between the Audio Module(s) and the GSM/Dual Comm module. 4. The maximum recommended XiB bus cable length between the power supply and the GSM/Dual Comm module is approximately 80m. This distance may be doubled if two cable cores are used for the power connections. This restriction is based on the peak current requirement of 180mA under poor signal conditions. 5. Insert a valid SIM card into the slot provided in the GSM engine. SIM code password protection must be disabled.
Introduction


DIL Switch Function 5 4 3 2 1 0 PSTN primary 0 1 GSM primary 5
When power is applied to the system the GSM module will power up in 3 stages: 1. The XiB communications will start before the end of system settling time (as indicated on the keypad). During this phase the XIB-comms LED will flash rapidly (awaiting secondary PSU start- up) 2. The GSM engine will start up after about 20 seconds. During this phase the XIB-comms LED will flash approximately once per second. 3. Once powered up, the GSM engine will be configured automatically and will attempt to acquire a service connection. This phase may take several minutes and no GSM calls should be attempted during this phase.
line · Engineer · Keypad


Function Colour State Meaning XiB Comms Green OFF No power ON Communication error Slow FLASH Operating normally Quick FLASH Active Hook Red ON Line seized Line monitor Green ON Valid Exchange voltage level present Quick flash Network search Slow flash Registered GSM Status Yellow
The available reporting formats for each route is shown in the table.

PSTN GSM (audio) GSM (data) Contact ID ADEMCO Fast/Superfast Format SIA Level 3 CESA (French panel variants only) Speech (if optional module fitted, v3.21 or later)
Audio (if optional module fitted) PS/2 (GSR) - 1200 baud PS/2 (GSR) - 9600 baud SMS (v4.00 or later) DIL Switches
To enable the Dual Comm module to be used with existing panels, the primary and secondary communicator routes are selected by DIL switch 5. DIL switches 1-4 are reserved for future use.
DIL Switch 5 4 3 2 1
0 PSTN is primary route 1 0 GSM is primary route The primary route is the normal route for all calls. If the primary route is PSTN then;
Function

The DGN (Data Gathering Network, the name of the concentrator bus used in Windsor 500/700) to XiB interface enables Vigil or Windsor 500 DGN concentrators to be connected to any XiB control panel (PX or QX). The XiB control panel must support the number of circuits and concentrators on the DGN bus (see table). The interface also allows DGN concentrator daughter board outputs to be controlled by the XiB control panel. If daughter boards are fitted to the DGN concentrators then the XiB control panel must be capable of supporting a corresponding number of output modules. Only one interface can be used in a system. The DGN supports anti-substitution and will report a concentrator tamper if a DGN concentrator is substituted with a concentrator with the same address. It is recommended that the DGN interface be mounted inside the control panel case using the supplied adhesive pads. The XiB connector of the DGN interface can be connected to any of the panel XiB busses and can share the bus with other XiB peripherals. Connect the bus cables from the concentrators to the DGN bus connections. Note that the order of the DGN bus connections may not be the same as the order of connections on the concentrators. (The DGN concentrator will have terminals marked CLK/DATA or S0/S1.)

XiB Bus In (from control panel)



Guardall Limited Lochend Industrial Estate
Newbridge Edinburgh EH28 8PL
Copyright © 2008 by Guardall Limited. All rights reserved