EN
Guardall logo
Official user manual

Guardall RX

46 pages·983 KB·Security·PDF·ENDEFRITNLJA
Guardall RX
Table of Contents 43 sections PX/QX/RX System · Version 4.30 · Installation Manual · Issue C · … ShowHide
Page 1 of the Guardall RX user manual — PX/QX/RX System
Page 1 · click to enlarge
Page 1
Guardall RX — PX/QX/RX System diagram (page 1)
Fig. 1 · PX/QX/RX System

PX/QX/RX System

Version 4.30

Installation Manual

Issue C

Page 2 of the Guardall RX user manual — PX/QX/RX System
Page 2 · click to enlarge
Page 2
Page 2 of the Guardall RX user manual — PX/QX/RX System
Page 3 of the Guardall RX user manual — PX/QX/RX System
Page 3 · click to enlarge
Page 3
Page 3 of the Guardall RX user manual — PX/QX/RX System
Page 4 of the Guardall RX user manual — STATUTORY REQUIREMENTS
Page 4 · click to enlarge
Page 4

STATUTORY REQUIREMENTS

Hereby Guardall declares that the RX16i, QX32i, PX48i and the PX80i are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. If you have any doubts concerning the suitability, connection or uses of this apparatus then consult a suitably qualified person before continuing. SUITABILITY FOR USE The apparatus has been designed to work on all European analogue networks and has been independently tested to TBR21. It provides the following facilities: 1. Alarm transmission and transmission/reception of configuration data. 2. Automatic Call Initiation. 3. Series connection. 4. Dial tone Detection 5. Automatic dialling using DTMF tones. 6. Automatic Call Answering. 7. Stored number dialling. 8. Timed Break Register Recall. It is not suitable for connection to PABX systems or for use as an extension to a payphone. EN50131 & PD6662 Compliance

PX, QX and RX are suitable for use in systems designed to comply with PD6662:2004. The grade and class of each variant is shown in the table.

Variant Grade Class RX16i/QX32i 2 II All PX 2 or 3 (Programmable) II Refer to the reset options in the engineer programming manual for details on programming the EN grade.

Page 5 of the Guardall RX user manual — STATUTORY REQUIREMENTS
Page 5 · click to enlarge
Page 5
Guardall RX — STATUTORY REQUIREMENTS diagram (page 5)
Fig. 2
BS EN61000-6-3:2001Generic Emission Standard For Residential, Commercial & Light Industry. EN 50130-4:1995 + A1:1998 + A2:2003Electromagnetic Compatibility Product Family Standard: Immunity Requirements for Components of Fire, Intruder and Social Alarm Systems. EN60950:2001Safety of Information Technology Equipment, including Electrical Business Equipment
Guardall RX — STATUTORY REQUIREMENTS diagram (page 5)
Fig. 3

The installation manual provides the information essential for wiring and operating the system. A full engineer manual (part number W76232) is available from Guardall. Copies of the engineer manual, and all other Guardall manuals, can be downloaded from the Guardall web site at,

www.guardall.co.uk The documentation section of the Guardall web site is password protected, and you may have to apply for access using the on-line form provided on the site. Alternatively a printed copy of the manual may be obtained by sending a FAX or letter to our Customer Helpline, requesting the full Engineering Manual.

Guardall RX — STATUTORY REQUIREMENTS diagram (page 5)
Fig. 4

Edinburgh EH28 8PL This manual and the PX/QX/RX systems described in it are copyrighted, with all rights reserved. This manual may not be copied except as expressly permitted in writing by Guardall Limited. Export of this technology may be controlled by the U.S. Government. Diversion contrary to U.S. Law prohibited.

Page 6 of the Guardall RX user manual — STATUTORY REQUIREMENTS
Page 6 · click to enlarge
Page 6

In this manual you will learn how to;

  • Identify the components of the PX system
  • Connect components together
  • Make simple configuration changes If you are new to the system it is recommended that you connect a basic system “on the bench” and familiarise yourself with programming the panel. Before getting started ensure you have the following components;
  • A control panel
  • A LCD keypad
  • A few meters of 4 core cable
  • A concentrator (optional) Now follow these simple steps:
  • Connect +, -, A and B terminals of the keypad ( CN6-XiB ) to the panel XiB (refer to the appropriate diagram in the panel section of this manual for details) using a length of 4 core cable. For simplicity of wiring adhere to the following colour coding;

+ Red - Black A Yellow B Blue • Set the address of the concentrator to address 1 (DIL switches 1-6 all off (0))

  • Connect +, -, A and B terminals of the concentrator ( CN2-XiB ) to the panel XiB connector using a length of 4 core cable using the same colour coding as used for the keypad connections.
Guardall RX — STATUTORY REQUIREMENTS diagram (page 6)
Fig. 5
Address = ??If the keypad has not been addressed then the prompt will be ?? or 99. or Press to exit address mode without change.
PX KP Type-nIf the displayed message is as shown, or no bleep is heard, then the Version 2.00keypad is not responding so check the bus connections.
DescriptionType Standard or with proximity reader1 With 2 EOL circuit inputs2

Getting Started

Page 7 of the Guardall RX user manual — STATUTORY REQUIREMENTS
Page 7 · click to enlarge
Page 7

Once the keypad is replying then enter the default engineer PIN code, 9999, remembering to validate the PIN code by pressing .

Guardall RX — STATUTORY REQUIREMENTS diagram (page 7)
Fig. 6

The PIN code digits are displayed as “*” characters.

As the system uses hazardous voltages it is recommended that the mains supply connection follow national wiring rules and is carried out by a suitably qualified person. This equipment must be permanently connected to a mains fused spur (3A or 5A). The mains cable should be clamped securely with the cable clamps provided within the equipment/installation kit. Knockouts are provided on the top, bottom and sides of this equipment and these are intended for conduit or cable glands. As a mains switch is not provided on the equipment, a readily accessible disconnect device shall be incorporated in the building installation wiring. Where there is doubt as to the phase of this wiring , the device, when operated, will disconnect both poles simultaneously. Mains Supply

Guardall RX — STATUTORY REQUIREMENTS diagram (page 7)
Fig. 7
ItemItemRX16i/QX32iPX48i/PX80iPX500/ PX250HS3A Smart Concentrator External power source230VAC +/- 10%, 50Hz Input current rating (AC)140mA220mA260mA330mA Mains FuseF315mA 250VF400mA 250VT630mA 250VT630mA 250V

The DC supply output is a Safety Extra-Low Voltage (SELV) circuit. This DC supply rating is for all the DC current requirements, including recharging the battery. The supply has the following rating:

Guardall RX — STATUTORY REQUIREMENTS diagram (page 7)
Fig. 8
ItemRX16i/PX48i/ PX80iPX500/ PX250HS3A Smart QX32iConcentrator Output voltage (DC)13.8V ± 5%14V ± 5%14V ± 0.1V14V ± 5% Standby Battery7Ah7Ah, 18 Ah7Ah, 12Ah or 18Ah2 off 18Ah Maximum recharge time24 hours24 hours24 hours24 hours Power supply rating1.0A1.50A2.5A3.0A Battery Charge Limit0.5A0.75A0.78A0.75A per battery Quiescent current85mA85mA80mA100mA Aux. DC supply (Fuse 1)F800mA 250VF800mA 250VF800mA 250VF1.6A 250V Aux. DC supply (Fuse 2)F800mA 250VF800mA 250VF800mA 250VF1.6A 250V External Bus Aux. DCF800mA 250V (Fuse 4)F800mA 250V (Fuse 4)F800mA 250V (Fuse 5) BatteryF1.6A 250V (Fuse 3)F2.5A 250V (Fuse 3)F2.5A 250V (Fuse 9)F2.5A 250V (Fuses 3 & 4) Internal Bus/Audio/Aux. DC (Fuse 5) XiB Bus 1-4F800mA 250V

All wiring in this enclosure requires to be V-2, IEC approved or PVC type. All installation wiring within this equipment should utilise plastic cable ties to bundle cables so as to provide strain relief for the cable.

Page 8 of the Guardall RX user manual — STATUTORY REQUIREMENTS
Page 8 · click to enlarge
Page 8
OrderDescription Code W76469RX16i Control panel (English) v4 W76468RX16i Control panel (Chubb) v4 W76491RX16i Control panel (Chubb SA) v4 W76481RX32i Control panel (English) v4 W76492RX32i Control panel (Chubb SA) v4 W76511PX48i Control panel (English) v4 W76483PX48i Control panel (Chubb) v4 W76475PX48i Control panel (Chubb RVR) v4 W76484PX80i Control panel (English) v4 W76493PX80i Control panel (Chubb SA) v4 W76195PX500 Control panel (English) v4 W76196PX500 Control panel (Chubb) v4 W76203PX250 High Security Control panel (English) v4 W76204PX250 High Security Control panel (Chubb) v4 W76247LCD Keypad 2 Line, 2 EOL circuits W76250LCD Keypad 2 Line, proximity & 2 EOL circuits W76251LCD Keypad 2 Line, 2 EOL circuits (Chubb) W76254LCD Keypad 2 Line, proximity & 2 EOL circuits (Chubb) W76289Mini Keypad W73821Proximity Reader W73820Proximity Fob Pack (2 off) W73837Proximity Card Pack (10 off) W76512Output Module (8 Relay/8 Transistor) W76068Serial Module (RS232) W73869Bus Isolator W72951Guardall Managed Reset PC software W73538Pin of the Day PC software W73534 UKGuardStation™ Modem W76546Programming Kit W76232PX Engineer Manual v4 (English) W73822Access Module W73847Smart Access Module W73840GuardStation™ Access W74334SmartKey Converter W74368Data comms Module (External) W74369Data comms Module (Internal) W74442Single Detector Interface (SDI) W76293GSR Professional v4 W76010GSR (direct) W76287Diagnostic Concentrator 4 Input/2 Output (Plastic) W74480Diagnostic Concentrator 8 Input/4 Output (Plastic)
OrderDescription Code W74481Universal 4 relay output board W763293A Smart Concentrator (8 input/4 output) W76110Radio Module (Visonic) W76067Radio Module (Inovonics) W76245Radio Repeater (Inovonics) W76094UTX 2-input with OTW tamper W760952-button pendant TX W760962-button belt clip TX W76097Shatter pro TX W76098Smoke detector TX W76099UTX (generic) with OTW tamper W76100Door/Window TX with OTW tamper W761011-button pendant TX W761021-button belt clip TX W76103PIR TX W762922-button TX (ES1238D) W76069Dual Comm Module W76070PSTN Module W76071GSM Module W76073Audio Bus Interface W76074Audio Bus Interface/Speech & Record W76050Speech module W76075TalkBack Module W76078Microphone Module W76076Microphone W76210DGN Interface W74364-channel video server W74541-channel video server

Order Codes

Page 9 of the Guardall RX user manual — STATUTORY REQUIREMENTS
Page 9 · click to enlarge
Page 9

A system comprises of the following components: 1. A control unit, which processes all the alarm information from the detection points. Outputs are provided to operate sounders, strobe and communication devices. Configuration information is stored in EEPROM. The manual details the features of the control panels. Most features in the PX panel range are common. The differences are shown in the table.

Feature RX16i QX32i PX48i PX80i PX500 PX250HS Max. Circuits 16 32 48 80 512 256 Max Concentrators 2 6 10 18 64 32 Circuit Doubling SDIs 8 8 8 16 32 32 Max. Panel Users 16 32 50 100 200 200 Max. Access Users 1000 Areas 4 8 8 16 32 16 Set Groups 8 8 16 32 16 Sub systems 4 4 8 16 8 Max Keypads 4 8 8 16 32 16 Output Modules 1 2 8 16 32 32 Output functions 16 16 20 64 128 128 Serial/Data comms Modules

2

Access Modules 32 Audio Modules 2 4 8 16 32 16 Radio Modules 1 2 4 8 16 8 Max. Transmitters 16 16 24 40 128 128 Video cameras 4 8 32 Responses 2 5 5 10 20 20 Tel Numbers 8 GSR profiles 1 2 4 Schedules 2 4 32 Holidays 14 20 Event Log Size 250 500 1000 1000 1000 2000 Access Log Size 1000 The diagram on the following page shows the bus peripheral connections. 2. User interaction with the system is via LCD keypad. There must be at least 1 keypad on a system. There are several types of LCD keypad available, which are detailed later. 3. On the RX16i, QX32i, PX48i and PX80i, up to 8 detectors may be connected directly to the panel. Further detectors, up to the control panel limit, may be connected to the system through concentrators on a 4-wire bus. Each concentrator provides 8 additional circuits. 4. Optional equipment includes;

1. A dialler/modem/Dual comm module 2. Output modules each with 8 programmable outputs 3. A serial module for connection of a printer or PC 4. Bus isolator 5. Access module 6. Data comms module for an Ethernet connection to a PC 7. Radio module 8. Audio module

System Components

Page 10 of the Guardall RX user manual — CF
Page 10 · click to enlarge
Page 10
Guardall RX — CF diagram (page 10)
Fig. 9

RX16i - 6 TX outputs QX32i - 6 TX outputs

Up to 3 external

CF

Show 5 more labels / short text on this page
TalkBack · Module · microphones · per module · LF Audio
Page 11 of the Guardall RX user manual — 8 8TX
Page 11 · click to enlarge
Page 11
Guardall RX — 8 8TX diagram (page 11)
Fig. 10

8 8TX

LF

Show 7 more labels / short text on this page
External bus · PX48i/ · PX80i · Sounder · Comm Fail · Strobe · Audio
Page 12 of the Guardall RX user manual — PX250HS
Page 12 · click to enlarge
Page 12
Guardall RX — PX250HS diagram (page 12)
Fig. 11

PX250HS

PX500

2 8TX

PX 34

Show 7 more labels / short text on this page
Bus 1 · Bus 2 · Bus 3 · Bus 4 · As · + · Sounder
Page 13 of the Guardall RX user manual — PX250HS
Page 13 · click to enlarge
Page 13
Guardall RX — PX250HS diagram (page 13)
Fig. 12

Parameter Range Temperature range -10 to 50 °C Humidity 10% to 90% relative humidity Technical Specification Cable Type

The system has a 4-wire bus for all peripherals. The recommended cable type is 7-strand/0.2mm2 diameter un-screened cable, which has a resistance of 90 ohms/km and a core to core capacitance of 85nF/km. The screened cable referred to in this manual has a capacitance of 68nF/km and a resistance of 39R/km. If screened cable is used it should be terminated in the control panel and connected to earth. Refer to the section on user interfaces and concentrators for details of the maximum length of cable on each bus. Technical Specification Cable Length

The maximum length, with a single standard keypad connected at the end of the cable and no other peripherals connected on the data bus, is shown in the table.

Guardall RX — PX250HS diagram (page 13)
Fig. 13

Maximum Data Bus Cable Length (m) Power Source Un-screened Cable Screened Cable Control Panel 600m 1900m Local Aux. PSU, with single 0v core

If auxiliary PSUs are used then all 0v connections must be connected to the control panel 0-volt terminal. It is not recommended practice to share a sensor connection and the data bus connections in the same cable. Technical Specification Operation Voltage

The operating voltage range of all XiB components is shown in the table.

Parameter Minimum Typical Maximum Voltage (volts) 10.5 v 13.5 v 15 v

Guardall RX — PX250HS diagram (page 13)
Fig. 14

Voltage (Volts) Condition > 11.7 Battery OK 11.4 Low Volts 10.7 Power Fail < 10.6 Deep discharge

Page 14 of the Guardall RX user manual — PX250HS
Page 14 · click to enlarge
Page 14

Technical Specification Current Consumption

Product Current (mA) RX16i/QX32i 76 PX48i/PX80i 85 PX500/PX250HS 80 Keypad (standard) 28 Keypad with proximity 85 Mini keypad 80 Concentrator (8-input) 42 Concentrator (4-input) 25 3A Smart Concentrator 100 Output module 22 (all relays off) Serial module 30 Access module 33 Proximity Reader 14 Bus isolator 25 Data comms Module 60 GSM/Dual Comm module 60 (standby) 125 (transmitting, strong signal present) 180 (transmitting, weak signal present) PSTN module 50 Audio Bus Interface Standby-6 Listen-6 Talk-10 Audio Bus Interface/Speech & Record

Standby-11 Playback-23 Record-32 TalkBack Module Standby-26 Listen-41 Talk-62 Microphone Module Standby-26 Listen-41 Microphone Standby-5 Listen-15 Speech module Standby-11 Playback-23 Record-32 Radio Module (Inovonics) 75 Radio Module (Visonic) 52 Technical Specification Battery Standby

The following example shows the average system current (excluding sensors) for a typical system at a supply voltage of 14 volts.

Guardall RX — PX250HS diagram (page 14)
Fig. 15

PX500/ PX250HS Panel 76 85 80 1 Keypad 28 28 28 1 Concentrator 42 42 42 Total (mA) 146 155 150 The table below shows the available auxiliary current for various battery sizes using the above typical system current.

Page 15 of the Guardall RX user manual — PX250HS
Page 15 · click to enlarge
Page 15

The power supply standby capacity specified in PD6662:2004 is shown in the table.

Grade 1 2 3 4 Standby time (hours) 12 12 24 24 The following tables show the maximum available system current with a minimum of 12 hours standby for each combination of power supply and battery size.

RX16i/QX32i (with 1A PSU) 24 hour battery re-charge time with a minimum 12 hours standby Battery Size Maximum recharge

Available Current (For sensors etc.)

7 Ah 500mA 500mA 14 hours 146mA 354mA

PX48i/PX80i (with 1.5A PSU) 24 hour battery re-charge time with a minimum 12 hours standby Battery Size Maximum recharge

Available Current (For sensors etc.)

7 Ah 750mA 580mA1 12 hours 155mA 425mA 12 Ah2 750mA 750mA 16 hours 155mA 595mA 17 Ah 750mA 750mA 22 hours 155mA 595mA 18 Ah 750mA 750mA 24 hours 155mA 595mA

PX500/PX250HS 24 hour battery re-charge time with a minimum 12 hours standby Battery Size Maximum recharge

Available Current (For sensors etc.) 7 Ah 780mA 580mA1 12 hours 150mA 430mA 12 Ah 780mA 1A1 12 hours 150mA 850mA 17 Ah 780mA 1.41A1 12 hours 150mA 1.26A 18 Ah 780mA 750mA1 24 hours 160mA 590mA

PX 500 current (example system)

1 Note that the maximum system current has been de-rated to provide the necessary standby capacity.

Show 19 more labels / short text on this page
System current · Available backup · RX16i/QX32i · current · maximum · period · current (example system) · System current · Available backup · PX48i/PX80i · current · maximum · period · current (example system) · System current · Available backup · current · maximum · period
Page 16 of the Guardall RX user manual — 8K2
Page 16 · click to enlarge
Page 16

Technical Specification EOL Resistor Connections

Type 1 EOL Network (Guardall) Type 2 EOL Network

The EOL resistors are fitted in the detector as shown. This wiring arrangement applies to all EOL inputs in the system. Note: The diagram shows the default values of 8k2//8k2. The EOL resistor value can be programmed (Refer to the system options for details.).

8K2

R1

R2

PX

EOL Network with Fault

The EOL resistors are fitted in the detector as shown. Note that the Guardall V12-AM detector has the necessary 3 EOL resistors fitted on board. For full information refer to the V12- AM manual. A fault EOL resistor may only be used if the system is programmed to use the standard Guardall resistor network.

Aux.

8K2

The resistance for each possible state is shown in the table and can be displayed using the circuit check mode function.

Guardall RX — 8K2 diagram (page 16)
Fig. 16

Circuit State Nominal Resistance Tamper 0k Clear 4k1 Alarm 8k2 Aux (Fault) 12k3 Aux+Alarm (Mask)

Show 9 more labels / short text on this page
Alarm Tamper · Alarm · 8k2 · PX Detector · Detector · 8k2 · Alarm · 8k2 · Panel Detector
Page 17 of the Guardall RX user manual — 8K2
Page 17 · click to enlarge
Page 17
Guardall RX — 8K2 diagram (page 17)
Fig. 17

The accuracy of the diagnostic system is typically less than 1%, with a maximum error 2.5%. This accuracy can only be achieved by programming the correct value of the 5V-reference voltage (option 69 on the main menu). Diagnostics Supply Measurements

Guardall RX — 8K2 diagram (page 17)
Fig. 18

Parameter Range Resolution Panel voltage 0-20v 78mV Panel battery voltage 0-20v 78mV System current 0-2A 7.8mA Battery Current 0-1.1A 4.4mA Battery standby capacity See Note 1 hour Concentrator current 0-250mA 1mA Concentrator voltage 0-15V 58mV Keypad voltage 0-15V 58mV Circuit resistance (for 8k2 EOL) 0-20K 70R Note: The displayed standby capacity will depend on the programmed battery size and the actual system current. Diagnostics XiB Comms LED

All XiB peripherals, except the keypad, have a green LED fitted, which is used to indicate the state of the XiB communications.

Guardall RX — 8K2 diagram (page 17)
Fig. 19

State Meaning OFF No power ON Communication error Slow FLASH Operating normally Quick FLASH Resetting, or frequency of polling in a dialler, serial module or IP module Diagnostics Circuit Limits

Pulse count 0 (Off) 0-255 0-255 Not Applicable Not

2 secs 2-255 seconds 2-255 seconds Not Applicable Not Applicable Tamper resistor

Alarm resistor 8k2 Programmable Programmable 8k2 8k2 Alarm/Tamper threshold

All percentages are with reference to the nominal programmed EOL value. The alarm and tamper EOL resistors are programmable. Refer to system options in the engineer manual for details.

Page 18 of the Guardall RX user manual — L K 4
Page 18 · click to enlarge
Page 18

Battery (max. 7 Ah)

L K 4

Guardall RX — L K 4 diagram (page 18)
Fig. 20

Visonic internal receiver interface. Note that if a receiver is connected then the on board serial port cannot be used.

RX16i/QX32i Control Unit · line Telephone

Page 19 of the Guardall RX user manual — L K 4
Page 19 · click to enlarge
Page 19
Guardall RX — L K 4 diagram (page 19)
Fig. 21

+ STB SPK - R COM NC NO RTN CF LF + - + - + - A B

TB B Earth A TA 1 C 2 3 C 4 5 C 6 7 C 8 TX1 TX2 TX3 TX4 TX5 TX6 TX7 TX8OP1 OP2

Page 20 of the Guardall RX user manual — L K 4
Page 20 · click to enlarge
Page 20

PX 80/500/HS Control Unit Installation

The PX 500 control panel is supplied with a spares bag containing the following items:

  • Battery lead
  • Cable clamp
  • 2.5A fuse
  • 800mA fuse x 6 (PX80) or x 8 (PX500/HS)
  • Screw No 6 x 19mm
  • 2 Screws No 6 x 9.5mm
  • 2 ty-wraps
  • 4 PCB stand-offs for fitting a XiB peripheral inside the case
  • Various 2, 3, 4 and 5 way plug-on connectors
  • 8k2 resistor x 2
  • Thermistor cable assembly. (battery temperature compensation) PX 80/500/HS Control Unit Case Layout

Mark the fixing positions shown and secure the rear case to the wall using 3 suitable screws. There are 2 x 20mm conduit knockout positions as indicated. The required cable entry point(s) should be knocked out from the inside prior to mounting the case. There are 4 trunking knockouts. These can be knocked out from either side. Conduit knockout Trunking knockouts STU or XiB peripheral Battery

Guardall RX — L K 4 diagram (page 20)
Fig. 22

Fixing holes Trunking knockout Off the wall tamper SmartDial or XiB peripheral Conduit knockout Trunking knockout

PX500/PX250HS Control Unit

Page 21 of the Guardall RX user manual — L K 4
Page 21 · click to enlarge
Page 21

PX500/PX250HS PCB Connections (PX500/PX250HS)

All PCB connections are plug-on screw down terminal blocks. The function and position of each terminal is described in the following page.

Guardall RX — L K 4 diagram (page 21)
Fig. 23

LK6: Fit link for 10s to default the configuration.

LK4: Connect thermistor cable and place thermistor on the battery.

Connect comm fail and line fault to v+ to disable

LK5: Battery disconnect disable. Fit link to power-up on battery.

Page 22 of the Guardall RX user manual — FS 1
Page 22 · click to enlarge
Page 22

Outputs 3&4 of 4-output concentrator may only be programmed on a contol panel fitted with version 3.10 or later.

6 5 4 3 2 1 1 0 2 0 1 3 0 1 0 4 0 1 1 5 0 0 0 1 0 0 6 0 0 0 1 0 1 7 0 0 0 1 1 0 8 0 0 0 1 1 1 9 0 0 1 0 0 0 10 0 0 1 0 0 1 11 0 0 1 0 1 0 12 0 0 1 0 1 1 13 0 0 1 1 0 0 14 0 0 1 1 0 1 15 0 0 1 1 1 0 16 0 0 17 0 1 0 18 0 1 0 0 0 1 19 0 1 0 0 1 0 20 0 1 0 0 1 1 21 0 1 0 1 0 0 22 0 1 0 1 0 1 23 0 1 0 1 1 0 24 0 1 0 1 1 1 25 0 1 1 0 0 0 26 0 1 1 0 0 1 27 0 1 1 0 1 0 28 0 1 1 0 1 1 29 0 1 1 1 0 0 30 0 1 1 1 0 1 31 0 1 0 32 0 1 33 1 0 34 1 0 1 35 1 0 0 0 1 0 36 1 0 0 0 1 1 37 1 0 0 1 0 0 38 1 0 0 1 0 1 39 1 0 0 1 1 0 40 1 0 0 1 1 1 41 1 0 1 0 0 0 42 1 0 1 0 0 1 43 1 0 1 0 1 0 44 1 0 1 0 1 1 45 1 0 1 1 0 0 46 1 0 1 1 0 1 47 1 0 1 1 1 0 48 1 0 1 49 1 1 0 50 1 1 0 0 0 1 51 1 1 0 0 1 0 52 1 1 0 0 1 1 53 1 1 0 1 0 0 54 1 1 0 1 0 1 55 1 1 0 1 1 0 56 1 1 0 1 1 1 57 1 1 1 0 0 0 58 1 1 1 0 0 1 59 1 1 1 0 1 0 60 1 1 1 0 1 1 61 0 0 62 1 0 1 63 1 0 64 1

1 ON OFF

PC1071A ADDRESS

8K2

8K2 ALARM

ALARM

Outputs 1-4 current limited to 250 mA

8K2

8K2

250 mA 250 mA

OP4

OP3

OP2

OP1

Case OTW Tamper Disable

FS 1

FS 2

Connect to control panel XiB bus

Show 22 more labels / short text on this page
8 Input Concentrator · Address DIL Switch · Smart PSU · Cct 1 · Interface · Cct 2 · Green · Red · Cct 3 · Cct 4 · + · Via FS 1 · + · Cct 5 · Cct 6 · Cct 7 · Cct 8 · + · Via FS 2 · + · Engineer · Keypad
Page 23 of the Guardall RX user manual — OP2
Page 23 · click to enlarge
Page 23

All 4 circuit inputs are fast inputs and can be programmed to allow a direct connection of an inertia sensor (refer to the engineer manual for details.)

7 6 5 4 3 2 1 1 0 2 0 1 3 0 1 0 4 0 1 1 5 0 1 0 0 6 0 1 0 1 7 0 1 1 0 8 0 1 1 1 9 0 0 0 1 0 0 0 10 1 0 0 1 11 0 0 0 1 0 1 0 12 0 0 0 1 0 1 1 13 0 0 0 1 1 0 0 14 0 0 0 1 1 0 1 15 0 0 0 1 1 1 0 16 0 0 0 17 0 0 1 0 18 0 0 1 0 0 0 1 19 0 0 1 0 0 1 0 20 0 0 1 0 0 1 1 21 0 0 1 0 1 0 0 22 0 0 1 0 1 0 1 23 0 0 1 0 1 1 0 24 0 0 1 0 1 1 1 25 0 0 1 1 0 0 0 26 0 0 1 1 0 0 1 27 0 0 1 1 0 1 0 28 0 0 1 1 0 1 1 29 0 0 1 1 1 0 0 30 0 0 1 1 1 0 1 31 0 0 1 0 32 0 0 1 33 0 1 0 34 0 1 0 1 35 0 1 0 0 0 1 0 36 0 1 0 0 0 1 1 37 0 1 0 0 1 0 0 38 0 1 0 0 1 0 1 39 0 1 0 0 1 1 0 40 0 1 0 0 1 1 1 41 0 1 0 1 0 0 0 42 0 1 0 1 0 0 1 43 0 1 0 1 0 1 0 44 0 1 0 1 0 1 1 45 0 1 0 1 1 0 0 46 0 1 0 1 1 0 1 47 0 1 0 1 1 1 0 48 0 1 0 1 49 0 1 1 0 50 0 1 1 0 0 0 1 51 0 1 1 0 0 1 0 52 0 1 1 0 0 1 1 53 0 1 1 0 1 0 0 54 0 1 1 0 1 0 1 55 0 1 1 0 1 1 0 56 0 1 1 0 1 1 1 57 0 1 1 1 0 0 0 58 0 1 1 1 0 0 1 59 0 1 1 1 0 1 0 60 0 1 1 1 0 1 1 61 0 1 0 0 62 0 1 0 1 63 0 1 0 64 0 1

7 6 5 4 3 2 1 65 1 0 66 1 0 1 67 1 0 1 0 68 1 0 1 1 69 1 0 0 0 1 0 0 70 1 0 0 0 1 0 1 71 1 0 0 0 1 1 0 72 1 0 0 0 1 1 1 73 1 0 0 1 0 0 0 74 1 0 0 1 0 0 1 75 1 0 0 1 0 1 0 76 1 0 0 1 0 1 1 77 1 0 0 1 1 0 0 78 1 0 0 1 1 0 1 79 1 0 0 1 1 1 0 80 1 0 0 1 81 1 0 1 0 82 1 0 1 0 0 0 1 83 1 0 1 0 0 1 0 84 1 0 1 0 0 1 1 85 1 0 1 0 1 0 0 86 1 0 1 0 1 0 1 87 1 0 1 0 1 1 0 88 1 0 1 0 1 1 1 89 1 0 1 1 0 0 0 90 1 0 1 1 0 0 1 91 1 0 1 1 0 1 0 92 1 0 1 1 0 1 1 93 1 0 1 1 1 0 0 94 1 0 1 1 1 0 1 95 1 0 1 0 96 1 0 1 97 1 1 0 98 1 1 0 1 99 1 1 0 0 0 1 0 100 1 1 0 0 0 1 1 101 1 1 0 0 1 0 0 102 1 1 0 0 1 0 1 103 1 1 0 0 1 1 0 104 1 1 0 0 105 1 1 0 1 0 0 0 106 1 1 0 1 0 0 1 107 1 1 0 1 0 1 0 108 1 1 0 1 0 1 1 109 1 1 0 1 1 0 0 110 1 1 0 1 1 0 1 111 1 1 0 1 1 1 0 112 1 1 0 113 1 1 1 0 114 1 1 1 0 0 0 1 115 1 1 1 0 0 1 0 116 1 1 1 0 0 1 1 117 1 1 1 0 1 0 0 118 1 1 1 0 1 0 1 119 1 1 1 0 1 1 0 120 1 1 1 0 121 0 0 0 122 1 0 0 1 123 1 0 1 0 124 1 0 1 1 125 1 0 0 126 1 0 1 127 1 0 128 1

PC1480

ON

OFF

8K2

ADDRESS

8K2 ALARM

DIL SW8 ON = Tamper disable

ALARM

8K2

8K2

Outputs 1 &2 current limited to 250 mA

OP2

OP1

Show 11 more labels / short text on this page
4 Input Concentrator · Address DIL Switch · Address DIL Switch · Cct 4 · Case · Cct 3 · Cct 2 · Cct 1 · Status · XiB · +
Page 24 of the Guardall RX user manual — 8K2
Page 24 · click to enlarge
Page 24

The 3A Smart concentrator can be used with a single battery or 2 batteries. If 2 batteries are used they should be of the same type and capacity. If a single battery is used it should be connected to the Batt 1 terminals. The case can accommodate 7Ah or 18Ah batteries. Deep discharge protection is provided for each battery.

Mains block F630mA 230v supply FS1 F1.6A Aux. 1 DC output (monitored)

FS2 F1.6A Aux. 2 DC output (monitored)

LK5 fiited 2A aux current/1A battery charge current LK5 not fitted 1.5A aux current/1.5A battery charge current LK8 External tamper disable

6 5 4 3 2 1 1 0 2 0 1 3 0 1 0 4 0 1 1 5 0 0 0 1 0 0 6 0 0 0 1 0 1 7 0 0 0 1 1 0 8 0 0 0 1 1 1 9 0 0 1 0 0 0 10 0 0 1 0 0 1 11 0 0 1 0 1 0 12 0 0 1 0 1 1 13 0 0 1 1 0 0 14 0 0 1 1 0 1 15 0 0 1 1 1 0 16 0 0 17 0 1 0 18 0 1 0 0 0 1 19 0 1 0 0 1 0 20 0 1 0 0 1 1 21 0 1 0 1 0 0 22 0 1 0 1 0 1 23 0 1 0 1 1 0 24 0 1 0 1 1 1 25 0 1 1 0 0 0 26 0 1 1 0 0 1 27 0 1 1 0 1 0 28 0 1 1 0 1 1 29 0 1 1 1 0 0 30 0 1 1 1 0 1 31 0 1 0 32 0 1 33 1 0 34 1 0 1 35 1 0 0 0 1 0 36 1 0 0 0 1 1 37 1 0 0 1 0 0 38 1 0 0 1 0 1 39 1 0 0 1 1 0 40 1 0 0 1 1 1 41 1 0 1 0 0 0 42 1 0 1 0 0 1 43 1 0 1 0 1 0 44 1 0 1 0 1 1 45 1 0 1 1 0 0 46 1 0 1 1 0 1 47 1 0 1 1 1 0 48 1 0 1 49 1 1 0 50 1 1 0 0 0 1 51 1 1 0 0 1 0 52 1 1 0 0 1 1 53 1 1 0 1 0 0 54 1 1 0 1 0 1 55 1 1 0 1 1 0 56 1 1 0 1 1 1 57 1 1 1 0 0 0 58 1 1 1 0 0 1 59 1 1 1 0 1 0 60 1 1 1 0 1 1 61 0 0 62 1 0 1 63 1 0 64 1

LK3 Batttery 1 deep discharge relay bypass

LK4 Batttery 2 deep discharge relay bypass

FS6 F2.5A Overvoltage protection

Link 4 Link 3

FS3 F2.5A Battery 1

FS4 F2.5A Battery 2

FS5 F800mA XiB out

LK1 Connect 0v to earth

LK9 Case tamper disable

FSx(2.5A)

FS3 (2.5A)

Battery 1 (7 or 18 Ah)

+ - + -

Charge voltage 13.7v+/-2%, temp. compensated

FS4 (2.5A)

Battery 2 (7 or 18 Ah)

circuits 1-10. Link 5

FS1(1.6A) FS2(1.6A)

+ - + -

14v +/-5%, 2A/1.5A max. (Refer to LK5)

- + + -

XiB bus in (from

1 ON OFF

ADDRESS

number. By default, inputs 1-10 are mapped to

8K2

switched off. There is no requirement to

terminate the input with the EOL resistors.

Each input can be mapped to any circuit

8K2

If an input is not used the circuit can be

8K2

Cct 5 Cct 6

8K2

OP4

OP3

OP2

OP1

OTW

(Ext.

Show 32 more labels / short text on this page
3A Smart Concentrator · Link 1 · Address DIL Switch · ac ~ ~ · Fuse Rating Function · Over Voltage · Batt 1 ISP · LK2 Tamper disable · Batt 2 · FS5 (800mA) · XiB bus out · Max 1700 m · (isolated) · control panel) · Cct7 Cct 8 · Alarm · Alarm · current limited to · Outputs 1-4 · Cct 4 · 250 mA · Cct 3 · Disable) · Link 9 · (Case · Case Tamper · Cct 2 · Disable) · Link 2 · Cct 1 · Link 8 · Disable)
Page 25 of the Guardall RX user manual — FS3 (2.5A)
Page 25 · click to enlarge
Page 25

The 3A Smart Concentrator has 2 XiB connectors, XiB in and XiB out. The XiB in connector must be used to connect the XiB bus from the panel. All 4 wires may be connected but the XiB in + terminal is not connected to the XiB out + terminal. The XiB out connector is used to connect all XiB peripherals that are to be powered from the 3A Smart Concentrator. The XiB out bus is electrically isolated from the XiB in bus and peripherals can be connected on the XiB out bus up to 1.7km from the 3A Smart concentrator (at 9k6 baud).

Guardall RX — FS3 (2.5A) diagram (page 25)
Fig. 24

XiB Busses

Page 26 of the Guardall RX user manual — FS3 (2.5A)
Page 26 · click to enlarge
Page 26
Guardall RX — FS3 (2.5A) diagram (page 26)
Fig. 25

Refer to the relevant XiB Detector installation manual for the connection details PQ15 XiB Manual Part No: 321094 PQ15-AM XiB Manual Part No: 321097 DT15+ XiB Manual Part No: 321106 DT15-AM XiB Manual Part No: 321113

XiB Detectors

Page 27 of the Guardall RX user manual — NO
Page 27 · click to enlarge
Page 27
Guardall RX — NO diagram (page 27)
Fig. 26

5 4 3 2 1 1 0 2 0 1 3 0 0 0 1 0 4 0 0 0 1 1 5 0 0 1 0 0 6 0 0 1 0 1 7 0 0 1 1 0 8 0 0 1 1 1 9 0 1 0 0 0 10 0 1 0 0 1 11 0 1 0 1 0 12 0 1 0 1 1 13 0 1 1 0 0 14 0 1 1 0 1 15 0 1 1 1 0 16 0 17 1 0 18 1 0 0 0 1 19 1 0 0 1 0 20 1 0 0 1 1 21 1 0 1 0 0 22 1 0 1 0 1 23 1 0 1 1 0 24 1 0 1 1 1 25 1 1 0 0 0 26 1 1 0 0 1 27 1 1 0 1 0 28 1 1 0 1 1 29 1 1 1 0 0 30 1 1 1 0 1 31 0 32 1

Guardall RX — NO diagram (page 27)
Fig. 27

The 10k pull up is reduced to approximately 500R if a relay is fitted to the same output channel.

NO

NC

NO

NC

NO

NC

NO

NC

Show 15 more labels / short text on this page
Output Module · TXoutputs · Connect to control · panel XiB bus · Not used · Output 8 · Output 4 · Output 7 · Output 3 · Output 6 · Output 2 · Output 5 · Output 1 · Engineer · keypad
Page 28 of the Guardall RX user manual — NO
Page 28 · click to enlarge
Page 28
Guardall RX — NO diagram (page 28)
Fig. 28
Guardall RX — NO diagram (page 28)
Fig. 29

RX V+ 0v TX Address DIL Switch 8 7 6 5 4 3 2 1 1 X 0 2 X 0 0 0 1

A serial module can be added at any time to a powered system but must be added to the system size before it will operate.

Guardall RX — NO diagram (page 28)
Fig. 30

The function switches only apply to versions up to v3.20.

Function DIL Switch 8 7 6 5 Printer/PC 0 Printer 0 0 0 1 PC 0 0 1 0

The printer format is fixed at 1200 baud, no parity, 8 data bits and 1 stop bit. PC baud rate is 9600.

Serial Module · Engineer Keypad

Page 29 of the Guardall RX user manual — NO
Page 29 · click to enlarge
Page 29
Guardall RX — NO diagram (page 29)
Fig. 31

Address DIL Switch 8 7 6 5 4 3 2 1 1 0 2 0 1

The data comms module address can be set to 1 or 2 only. If a serial module is connected to the system then the serial module and data comms module addresses must be unique.

Data Comms Module · Engineer · Keypad

Page 30 of the Guardall RX user manual — NO
Page 30 · click to enlarge
Page 30
Guardall RX — NO diagram (page 30)
Fig. 32

To set the address, create a case tamper and the press and hold down the ? button for a few seconds. Enter the address number when prompted.

Page 31 of the Guardall RX user manual — NO
Page 31 · click to enlarge
Page 31

The mini LCD proximity keypad is supported from v4.20.

Mini Keypad

Page 32 of the Guardall RX user manual — NO
Page 32 · click to enlarge
Page 32

The XiB bus isolator can be used to both extend the maximum XiB cable length and to electrically isolate parts of the bus. The maximum bus extension will depend on the cable type and the supply voltage. Up to 2 bus isolators may be connected in series, giving a total bus length of 5.1km using standard un-screened cable. Refer to the Technical Specification section for the cable specification. Bus Isolator PCB Connections

Guardall RX — NO diagram (page 32)
Fig. 33

XiB Bus In (from control

Bus Isolator · XiB Bus out · panel)

Page 33 of the Guardall RX user manual — RTE (N.O.)
Page 33 · click to enlarge
Page 33

(8A)

(2A)

Guardall RX — (8A) diagram (page 33)
Fig. 34

Address DIL Switch 5 4 3 2 1 1 0 2 0 1 3 0 0 0 1 0 4 0 0 0 1 1 5 0 0 1 0 0 6 0 0 1 0 1 7 0 0 1 1 0 8 0 0 1 1 1 9 0 1 0 0 0 10 0 1 0 0 1 11 0 1 0 1 0 12 0 1 0 1 1 13 0 1 1 0 0 14 0 1 1 0 1 15 0 1 1 1 0 16 0 17 1 0 18 1 0 0 0 1 19 1 0 0 1 0 20 1 0 0 1 1 21 1 0 1 0 0 22 1 0 1 0 1 23 1 0 1 1 0 24 1 0 1 1 1 25 1 1 0 0 0 26 1 1 0 0 1 27 1 1 0 1 0 28 1 1 0 1 1 29 1 1 1 0 0 30 1 1 1 0 1 31 0 32 1

Guardall RX — (8A) diagram (page 33)
Fig. 35

DIL SW 8 - Tamper Disable DIL SW7 - Default config DIL SW6 - Not used

RTE (N.O.)

To default the access module configuration power up with SW7 ON and return SW7 to the Off after a few seconds.

Door (N.C.)

Reader supply voltage - Select 12v for Guardall readers.

Access Module · Door Relay · AUX Relay

Page 34 of the Guardall RX user manual — Max. 150m
Page 34 · click to enlarge
Page 34
Guardall RX — Max. 150m diagram (page 34)
Fig. 36 · Max. 150m

The Proximity Reader is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Whilst it operates on a non-harmonised frequency of 125KHz, it meets all relevant harmonised standards. It has been notified in the following EU countries: Belgium, Italy, France, The Netherlands, Denmark, Finland, UK, Ireland, Germany, Spain, Portugal, Norway, Greece and Sweden. Proximity Reader Access Module Connections

Guardall RX — Max. 150m diagram (page 34)
Fig. 37 · Max. 150m
Guardall RX — Max. 150m diagram (page 34)
Fig. 38 · Max. 150m

The diagram shows a Guardall reader. Other types of reader may be used. Refer to the engineer programming manual (System/card types) for details.

Black, 0 Volt

Brown, LED green

Green, LED red

Blue, DATA 1/Data

Black, 0 Volt

Brown, LED green

Green, LED red

Reader supply voltage - Select 12v for Guardall readers.

Blue, DATA 1/Data

Orange, DATA 0/Clock

Max. 150m

Ground

Page 35 of the Guardall RX user manual — Max. 150m
Page 35 · click to enlarge
Page 35

Proximity Reader Keypad Connections

Guardall RX — Max. 150m diagram (page 35)
Fig. 39 · Max. 150m

To Drive an LED directly from a keypad connect either the brown wire (Green LED) or the green wire (Red LED) to the OP terminal of the keypad. The keypad output can be programmed for set, entry/exit or any other output function.

The diagram shows a Guardall reader. Other types of reader may be used. Refer to the engineer programming manual (System/card types) for details.

It is not recommended practice to share a sensor connection and the data bus connections in the same cable.

Page 36 of the Guardall RX user manual — Max. 150m
Page 36 · click to enlarge
Page 36
Guardall RX — Max. 150m diagram (page 36)
Fig. 40 · Max. 150m

Function Red LED Green LED Door LOCKED ON OFF Door UNLOCKED ON ON INVALID card, Access DENIED or Access ACCEPTED but door not opened.

ON ON (when door open and locked, flash on for 1 second) Access ACCEPTED, Area was in alarm

Door FORCED Alarm Flash ON Door TAMPER Alarm Flash ON Door area set OFF blink for 10 secs, then goes to Door Locked Door OPEN Alarm Start / Finish

Door area setting Slow flash on both LEDs Module logging data or undergoing configuration

Page 37 of the Guardall RX user manual — Max. 150m
Page 37 · click to enlarge
Page 37
Guardall RX — Max. 150m diagram (page 37)
Fig. 41 · Max. 150m
Guardall RX — Max. 150m diagram (page 37)
Fig. 42 · Max. 150m

Address DIL Switch 5 4 3 2 1 1 0 2 0 1 3 0 0 0 1 0 4 0 0 0 1 1 5 0 0 1 0 0 6 0 0 1 0 1 7 0 0 1 1 0 8 0 0 1 1 1 9 0 1 0 0 0 10 0 1 0 0 1 11 0 1 0 1 0 12 0 1 0 1 1 13 0 1 1 0 0 14 0 1 1 0 1 15 0 1 1 1 0 16 0 17 1 0 18 1 0 0 0 1 19 1 0 0 1 0 20 1 0 0 1 1 21 1 0 1 0 0 22 1 0 1 0 1 23 1 0 1 1 0 24 1 0 1 1 1 25 1 1 0 0 0 26 1 1 0 0 1 27 1 1 0 1 0 28 1 1 0 1 1 29 1 1 1 0 0 30 1 1 1 0 1 31 0 32 1

- IP3 + SW - IP2 + SW - IP1 + SW

Audio Module · Red Black · External microphone connections

Page 38 of the Guardall RX user manual — R, -
Page 38 · click to enlarge
Page 38

Audio System Connecting an External Microphone

Up to 3 external microphones can be connected to each audio module. The sensitivity of each external microphones can be increased by fitting the appropriate link (MIC1, MIC2 or MIC3) on the audio module PCB.

Guardall RX — R, - diagram (page 38)
Fig. 43

R, -

- IP3 + SW - IP2 + SW - IP1 + SW

Audio System Connecting the Audio Bus Interface

The Audio Bus Interface (ABI) can be fitted, along with an Audio Module, to provide audio capability to the system. For systems requiring the ability to record and playback messages, a speech module is fitted in place of an ABI. Either board should be fitted with the power removed from the Control Panel. Power should only be restored after the alignment of the two boards has been checked.

Guardall RX — R, - diagram (page 38)
Fig. 44
Page 39 of the Guardall RX user manual — R, -
Page 39 · click to enlarge
Page 39

The radio module is fitted with 2 PCBs; a RF module and a serial interface for connection to the control panel XiB bus. The serial interface PCB is multi-function and for operation as a radio interface DIL switches 6 and 8 must be on and DIL switch 7 off. DIL switches 1-5 are used to select the radio module address. The diagram shows the Inovonics receiver module (W76067). The Visonic radio module (W76110) internal layout is similar. Refer to the serial module section for the connection details. The radio module type must be programmed. Refer to the radio options in the engineer manual for more information.

Guardall RX — R, - diagram (page 39)
Fig. 45

DIL switches 6-8 are factory set to the radio module function

Function DIL Switch 8 7 6 Radio 1 0 1

A radio repeater(s) may be added to the system. Each radio repeater should be added as a transmitter (refer to the engineer manual for details).

Radio Module

Page 40 of the Guardall RX user manual — R, -
Page 40 · click to enlarge
Page 40

Hereby Guardall, declares that the Dual comm module and PSTN module is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. If you have any doubts concerning the suitability, connection or uses of this apparatus then consult a suitably qualified person before continuing. SUITABILITY FOR USE The apparatus has been designed to work on all European analogue networks. It provides the following facilities: 1. Alarm transmission and transmission/reception of configuration data. 2. Automatic Call Initiation. 3. Series connection. 4. Dial tone Detection 5. Automatic dialling using DTMF tones. 6. Automatic Call Answering. 7. Stored number dialling. 8. Timed Break Register Recall. It is not suitable for connection to PABX systems or for use as an extension to a payphone. The Dual comm module and the GSM module are fitted with a GSM engine which has been declared compliant with the essential requirements of Directive 1995/05/EC by the manufacturer Dia telecom Spa (Telit). The conformity assessment procedure referred to in Article 10 and detailed in Annex IV of Directive 1999/05/EC was carried out by a Notified Body, namely BABT, Walton-on-Thames, UK (Notified body number 0168). The GSM engine complies with the following standards:

  • EN301511, 3GPP51.010-1 – GSM (Radio Spectrum) standard
  • EN301489-1 & EN301489-7 – EMC Standard
  • BS EN60950:2002 - Safety of information equipment

GSM/Dual Comm module · Statutory Requirements

Page 41 of the Guardall RX user manual — R, -
Page 41 · click to enlarge
Page 41

The Dual Comm module, GSM module and the PSTN module may be used with any Guardall control panel.

Guardall RX — R, - diagram (page 41)
Fig. 46

Feature Implementation Transmission Voice and Data Frequency Band Dual Band EGSM900 and EGSM1800 Transmit Power Class 4 (2W) for EGSM 900MHz Class 1 (1W) for EGSM 1800MHz Data 9.6Kbps Supported SIM card 3V cards There are a number of important points to consider when using one of the new module types with an existing panel: 1. All previous communicators were designed for use within the panel case and consequently they were designed with no tamper switch. The GSM/Dual comm module is intended for use outside the panel case, and so needs a case tamper. The GSM/Dual comm module case tamper is recognised from panel v4. If the GSM/Dual comm module used with earlier panel versions it is recommended that line fault monitoring is enabled to act as a substitute for the tamper sensing. 2. The Dual comm module functions are programmed using the DIL switches. Future versions of the firmware will include additional menu options for GSM programmable functions. The version number of the first release of firmware is v4.50. This is necessary to enable older panel versions to recognise the module and allow access to the appropriate programming menus Installation

Special care is required when installing the GSM module or Dual Comm module; 1. Avoid placement on metal surfaces to ensure good radio performance. 2. To minimise GSM transmission interference, route all cables away from the GSM antenna. 3. If the system includes Audio Modules ensure that there is at least 3m between the Audio Module(s) and the GSM/Dual Comm module. 4. The maximum recommended XiB bus cable length between the power supply and the GSM/Dual Comm module is approximately 80m. This distance may be doubled if two cable cores are used for the power connections. This restriction is based on the peak current requirement of 180mA under poor signal conditions. 5. Insert a valid SIM card into the slot provided in the GSM engine. SIM code password protection must be disabled.

Introduction

Page 42 of the Guardall RX user manual — GSM Antenna Avoid running cables near to the GSM antenna
Page 42 · click to enlarge
Page 42
Guardall RX — GSM Antenna Avoid running cables near to the GSM antenna diagram (page 42)
Fig. 47 · GSM Antenna Avoid running cables near to the GSM ant…

GSM Antenna Avoid running cables near to the GSM antenna

DIL Switch Function 5 4 3 2 1 0 PSTN primary 0 1 GSM primary 5

When power is applied to the system the GSM module will power up in 3 stages: 1. The XiB communications will start before the end of system settling time (as indicated on the keypad). During this phase the XIB-comms LED will flash rapidly (awaiting secondary PSU start- up) 2. The GSM engine will start up after about 20 seconds. During this phase the XIB-comms LED will flash approximately once per second. 3. Once powered up, the GSM engine will be configured automatically and will attempt to acquire a service connection. This phase may take several minutes and no GSM calls should be attempted during this phase.

line · Engineer · Keypad

Page 43 of the Guardall RX user manual — GSM Antenna Avoid running cables near to the GSM antenna
Page 43 · click to enlarge
Page 43
Guardall RX — GSM Antenna Avoid running cables near to the GSM antenna diagram (page 43)
Fig. 48 · GSM Antenna Avoid running cables near to the GSM ant…

Function Colour State Meaning XiB Comms Green OFF No power ON Communication error Slow FLASH Operating normally Quick FLASH Active Hook Red ON Line seized Line monitor Green ON Valid Exchange voltage level present Quick flash Network search Slow flash Registered GSM Status Yellow

The available reporting formats for each route is shown in the table.

Guardall RX — GSM Antenna Avoid running cables near to the GSM antenna diagram (page 43)
Fig. 49 · GSM Antenna Avoid running cables near to the GSM ant…

PSTN GSM (audio) GSM (data) Contact ID ADEMCO Fast/Superfast Format SIA Level 3 CESA (French panel variants only) Speech (if optional module fitted, v3.21 or later)

Audio (if optional module fitted) PS/2 (GSR) - 1200 baud PS/2 (GSR) - 9600 baud SMS (v4.00 or later) DIL Switches

To enable the Dual Comm module to be used with existing panels, the primary and secondary communicator routes are selected by DIL switch 5. DIL switches 1-4 are reserved for future use.

DIL Switch 5 4 3 2 1

0 PSTN is primary route 1 0 GSM is primary route The primary route is the normal route for all calls. If the primary route is PSTN then;

  • All calls in all formats will be routed over the PSTN network
  • If there is a PSTN line fault then all calls will be routed over the GSM network (refer to the reporting formats table for details) Note: If the call format is PS/2 and there is a PSTN line fault then the call will be made on the same number of GSM. This call will fail as the Windsor modem and GSM modem will use different telephone numbers. If the primary route is GSM then;
  • All calls in all formats will be routed over the GSM network
  • If there is no GSM service available then all calls will be routed over the PSTN network (refer to the reporting formats table for details)

Function

Page 44 of the Guardall RX user manual — GSM Antenna Avoid running cables near to the GSM antenna
Page 44 · click to enlarge
Page 44

The DGN (Data Gathering Network, the name of the concentrator bus used in Windsor 500/700) to XiB interface enables Vigil or Windsor 500 DGN concentrators to be connected to any XiB control panel (PX or QX). The XiB control panel must support the number of circuits and concentrators on the DGN bus (see table). The interface also allows DGN concentrator daughter board outputs to be controlled by the XiB control panel. If daughter boards are fitted to the DGN concentrators then the XiB control panel must be capable of supporting a corresponding number of output modules. Only one interface can be used in a system. The DGN supports anti-substitution and will report a concentrator tamper if a DGN concentrator is substituted with a concentrator with the same address. It is recommended that the DGN interface be mounted inside the control panel case using the supplied adhesive pads. The XiB connector of the DGN interface can be connected to any of the panel XiB busses and can share the bus with other XiB peripherals. Connect the bus cables from the concentrators to the DGN bus connections. Note that the order of the DGN bus connections may not be the same as the order of connections on the concentrators. (The DGN concentrator will have terminals marked CLK/DATA or S0/S1.)

Guardall RX — GSM Antenna Avoid running cables near to the GSM antenna diagram (page 44)
Fig. 50 · GSM Antenna Avoid running cables near to the GSM ant…

XiB Bus In (from control panel)

Show 4 more labels / short text on this page
DGN Interface · from concentrators · DGN Bus · (600m max)
Page 45 of the Guardall RX user manual — GSM Antenna Avoid running cables near to the GSM antenna
Page 45 · click to enlarge
Page 45
Page 45 of the Guardall RX user manual — GSM Antenna Avoid running cables near to the GSM antenna
Page 46 of the Guardall RX user manual — GSM Antenna Avoid running cables near to the GSM antenna
Page 46 · click to enlarge
Page 46

Guardall Limited Lochend Industrial Estate

Newbridge Edinburgh EH28 8PL

Tel0131-333-2900 FAX: 0131-333-4919

www.guardall.co.uk

Technical Hotline0131-333-3802
Part Number320994-0C

Copyright © 2008 by Guardall Limited. All rights reserved

Ask about the Guardall RX

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Guardall RX

Be the first to ask — other owners or our team will answer.

Original document

Guardall RX manual PDF

46 pages·983 KB·Security·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…