Page 1 of the Gram KPS40 user manual — S/N
Page 1 · click to enlarge
Page 1
Gram KPS40 — Instructions for use diagram (page 1)
Fig. 1 · Instructions for use
Gram KPS40 — Instructions for use diagram (page 1)
Fig. 2 · Instructions for use

WHAT YOU SHOULD KNOW ABOUT OUR NEW GRAM PRODUCTS

Instructions for use

Gram KPS40 — Instructions for use diagram (page 1)
Fig. 3 · Instructions for use
Gram KPS40 — Instructions for use diagram (page 1)
Fig. 4 · Instructions for use

GRAM PROCESS · KPS Shock Cooler and Shot Freezer

GRAM PROCESS · KPS Shock Cooler and Shot Freezer

Gram KPS40 — GRAM PROCESS · KPS Shock Cooler and Shot Freezer diagram (page 1)
Fig. 5 · GRAM PROCESS · KPS Shock Cooler and Shot Freezer
Gram KPS40 — GRAM PROCESS · KPS Shock Cooler and Shot Freezer diagram (page 1)
Fig. 6 · GRAM PROCESS · KPS Shock Cooler and Shot Freezer
Gram KPS40 — GRAM PROCESS · KPS Shock Cooler and Shot Freezer diagram (page 1)
Fig. 7 · GRAM PROCESS · KPS Shock Cooler and Shot Freezer
Gram KPS40 — GRAM PROCESS · KPS Shock Cooler and Shot Freezer diagram (page 1)
Fig. 8 · GRAM PROCESS · KPS Shock Cooler and Shot Freezer

Part No

S/N

Type · Type

Page 2 of the Gram KPS40 user manual — Support
Page 2 · click to enlarge
Page 2

Thank you for choosing a GRAM product

This guidance is divided into two main components, a main part and an additional part.

The main part deals with the absolutely necessary functions for operating the devices. The supplementary part provides information about the various extra functions. It should be mentioned here that no device works completely maintenance-free, but prevent correct use and care unnecessary interference.

Easy to use, total control

GRAM KPS devices meet all the requirements of HACCP for operating a Cook & Chill kitchen. The entire range of KPS devices uses the same control with the quick start buttons for easy selection of the desired cooling mode. To achieve greater flexibility, you can also use your own shock cooling or refrigeration systems. Deposit shock freezing programs.

If operational failures occur, they are displayed in the display via a fault code. Possible reasons and possibilities for resolving the malfunction are described in this guide.

All KPS devices use HCFC-free insulation.

Gram KPS40 — Easy to use, total control diagram (page 2)
Fig. 9 · Easy to use, total control

Support

Attention

Please note Type / Part No. / S/N (series) of

If you need information that is not available in this user manual, our service department will be happy to help. Many questions can often be answered by phone.

nameplate of your device in the three white fields on the

Front page of your guide.

See below the section

“Service” where the

Contact details for the service department: See the back.

g:

Device is controlled.

Compliance with the RoHS Directive On 1 January Directive 2002/95/EC entered into force on 1 July 2006. It concerns the RoHS Directive (English: Restriction of Ha-zardous Substances Directive; German: “Restriction on the use of certain hazardous substances”). The RoHS Directive entered 1. In force on July 1, 2006, it was implemented as a directive in all EU member states. This Directive restricts the use of six hazardous substances in the manufacture of different types of electrical and electronic equipment. The directive instructs manufacturers to find alternatives to these substances.

The six prohibited substances are: lead/mercury/cadmium/hexavalent chromium/polybrominated biphenyls (PBB)/polybrominational diphenylethers (BDE). As proof that Gram Commercial and our suppliers comply with the law, our company has a RoH’s explanation.

CE marking Certifies that a product has complied with the applicable EU directives regarding consumer safety, health or environmental requirements.

ie · Nameplate on your

Page 3 of the Gram KPS40 user manual — Content
Page 3 · click to enlarge
Page 3

Content

Other supplementary

Information

Installation and preparation 6

Settings of shock-cooling frost programs, temperature controlled, time controlled

Connection of the devices 7

Storage of user programs 16

Use of own programs 19

Quick Guide (Appendix to the binding)

Input/output values 27

Show 25 more labels / short text on this page
General 4 · Duty cycles 14 · Programming of user programs · Installation 6 · Start-up 8 · Voice, date and time settings · IFR program 17 · Precool 9 · Use of preset programs · Quick start button 10 · Maintenance 11 · Pre-cooling 19 · Cleaning 11 · Storage programs 20 · Twisting water 11 · Fault codes 22 · Service 12 · Overview 22 · Additional 24 · Sterilization program 24 · Data printout 24 · Alarm messages 25 · Keyboard lock 26 · Service parameters 26 · Disposal 28
Page 4 of the Gram KPS40 user manual — General
Page 4 · click to enlarge
Page 4

General

The following models are captured with this user manual:

General about the use of devices.

KPS 20, 40, 60, 90, 120 and 180.

KPS devices are not storage equipment. An automatic defrosting does not take place. Use the provided quick start button to activate a defrost (see )Quick start buttons“Page 10 or Quick Guide”

The models in this guide are called devices, although the types KPS 120 and 180 are walk-in refrigeration rooms.

Some functions or characteristics may vary from device to device, differences are pointed out.

After the end of a shock cooling or frost cycle, the system automatically goes into storage mode (+2°C at the ends of the shock cooling process and -22°C) at the conclusion of the flash freeze process. If the device is working in the storage program, the display showsCons”.

Figure 1:

To achieve efficiency cooling results, it is advisable to cool the device before charging by the “pre-cooling cycle”.

It is important to place the core temperature sensor exactly. If you choose the IFR program, the “disc” of the core temperature sensor must rise on the surface of the food. For the other programs, the core temperature sensor should be placed so that the probe tip reaches approximately the middle of the products to be cooled (see Figure 1).

Show 8 more labels / short text on this page
> · > · > · > · > · Product surface area > · >
Page 5 of the Gram KPS40 user manual — General
Page 5 · click to enlarge
Page 5

Build up this guidance.

use of displays.

This guidance document is divided into the following two parts:

This guide refers to the text on display as shown below, for example:

Main part (S. 4 - 13) Supplementary part (S. 14 - 28)

Date 10/02/09 Zeit: 14:22:46

The Main part It deals with the basic functions. Knowledge of these is necessary for the correct use of devices.

The control panel is equipped with the display and a keyboard located under the display.

The supplementary part deals with the special functions, including preset programs, storage and use of user programs.

Use them to the advantage of Quick Guide for explaining the 5 quick start buttons and their correct operation.

In addition, the operating manual has a Quick Guide with an overview of the most common functions and their use.

Show 8 more labels / short text on this page
> · > · Example · > · > · > · > · >
Page 6 of the Gram KPS40 user manual — KPS 20/40
Page 6 · click to enlarge
Page 6

Installation and preparation

Installation of the installation

Correct installation of the device before use.

Further installation instructions.

To ensure a reliable function, you see that the following has been taken into account:

Please place the equipment because of risk of corrosion, not in a chlorinated atmosphere (swimming pool etc.)

The KPS 20, 40 and 90 are supplied with height-adjustable legs and interchangeable door seal. The door stop of the KPS 40 is also replaceable. !

The device must be placed in a dry well-ventilated room.

The devices are designed for working at ambient temperatures up to +30°C. Prevent direct sunlight and set up directly next to heat sources (e.g.) Ovens.

The devices can be placed directly on a wall. KPS 20 and 40 shall be at least 100 mm from the wall and 50 mm upwards.

For devices with feet, use the adjustment options of the feet to bring the devices into a horizontal position in all directions.

KPS 20/40

Before using the equipment, clean it with a mild soapy solution and dry it carefully.

If the devices have been transported lying down, leave them standing upright for 2 hours before starting. This applies only to devices ready for plugging.

Show 7 more labels / short text on this page
> · > · > · > · > · > · >
Page 7 of the Gram KPS40 user manual — Connection of equipment
Page 7 · click to enlarge
Page 7

Connection of equipment

Read this text carefully before the electrical connection.

Connection of devices – Continuation.

KPS 40, 60, 90 120 and 180 must be connected by an authorized electrician.

Do not use the devices before all protective equipment is installed. Help prevent accidents.

Do not use devices with defective lines. In these cases, an investigation by an authorized service technician is absolutely necessary.

The KPS 20 can be connected by the operator himself.

When the device is connected,

The equipment should not be used outdoors. All necessary grounding measures based on the information provided by the local energy supplier should be observed. If necessary, consult an electrical specialist. !

Button to turn on the device.

If you had a power interruption during operation, the controller keeps the settings stored. When the energy supply is active again, the program continues where the interruption of energy occurred.

For KPS 60, 90, 120 and 180 The condensation water must be removed on the building side (see page). 11).

KPS 20 and 40 are equipped with a condensation water collecting pan which is in the apparatus when delivered. The operator should insert this shell after installation of the device, under it. The dish must be emptied if necessary. Alternatively, the devices can also be connected to an external sequence.

Show 4 more labels / short text on this page
> · > · > · >
Page 8 of the Gram KPS40 user manual — !
Page 8 · click to enlarge
Page 8

Entry into service

Language, date and time

It's easy to start the device. The Quick Guide gives you a clear overview of the control panel.

Connect your device to the power supply and, if necessary, sewage drain (see section “)Connection”).

Then the button and the

Button until the display shows “Language”:

If the device is not switched on

is, press the

Button to turn on the device.

Then the button, and the display shows:

Then press them down.

-Button twice and the following ad appears:

Room xx °C Menu

Button until the language you want appears.

Keys to select the desired menu.

Confirm with them.

button. The display now showsLanguage Esc
Remarksxx°C = Current room temperature

!

Language, date and time: It is recommended to set the language, date and time immediately.

Main menuThe main menu can be set at any time by double

Press the MENU button.

Button again and the display shows:

Room xx °C Menu

For better illustration, it makes sense to Quick Guide to help. It clearly illustrates the function keys and their main functions.

Show 14 more labels / short text on this page
> · > · > · Language esc · > · > · English esc · > · or > · Use the · and > · Clock setting esc
Page 9 of the Gram KPS40 user manual — !
Page 9 · click to enlarge
Page 9

Pre-cooling

Language, date and time - continuation.

It is useful to start a pre-cooling cycle for cooling the interior of the device before using the individual programs. To find out how to start the pre-cooling cycle, use the Quick Guide.

button. The display shows:

Date 10/02/09 Zeit: 14:22:46

!

After the pre-cooling has been completed, the display shows:

The buttons change the flashing signs.

Room -25 °C product plug in

Save the settings and switch to the next flashing sign.

If the food has been brought in and the door closed, the advertisement shows:

By pressing twice the

Room xx °C Menu

Then return to the main menu. Then the display shows that Main menu:

Now the desired program can be started (see Quick Guide).

Room xx °C Menu

!

Take them out. Quick Guide for further information.

The quick start buttons can only be started from the main menu (see display “main menu”).

Show 6 more labels / short text on this page
> · > · Example · > · > · >
Page 10 of the Gram KPS40 user manual — !
Page 10 · click to enlarge
Page 10

Quick start buttons

5 buttons also serve as quick start keys. To activate it, press for 5 seconds.

!

Please read the Quick Guide for further information. The quick start buttons can only be activated from the main menu level.

Activates a defrosting process. If defrosting is not required, this function will not be activated.

Activates the IFR process. IFR automatically adapts the cooling process to the characteristics of the means of life. By using the IFR program, the danger of surface ächenfrost is minimized. (see p.a.) 17 under “IFR” for more information.

Room xx °C Menu

Activates the shock freeze process (shock freezer button).

Activates the shock cooling process (shock cool button).

Activates the pre-cooling process. If it is pressed only briefly, then repeats the last activated process sequence.

Show 5 more labels / short text on this page
> · > · > · > · >
Page 11 of the Gram KPS40 user manual — Cleaning
Page 11 · click to enlarge
Page 11

Maintenance

Cleaning

Twisting water

If the device is not cleaned properly, this can lead to a lack of efficiency or efficiencies. cause disruption of operation.

Since the KPS devices do not evaporate condensation water, please consider:

KPS 60, 90, 120 and 180 shall be connected to an external condensation water drain.

Before cleaning, make device powerless!

The device should be cleaned inside regularly with a mild soapy solution.

For KPS 20 and 40 The following applies: A condensation dish is located under the device. The shell should be emptied daily or if necessary. Alternatively, these devices can also be connected to an external outlet.

For external cleaning, use stainless steel plaster.

The compressor unit and in particular the condenser (ready-to-use devices) must be kept free of dirt. Cleaning is best done by a vacuum cleaner and soft brush.

For cleaning the condensation dish see opposite section to “Twisting water”.

Defrosting: A KPS device does not automatically defrost. Usually, it is not necessary to thaw. If it is necessary, please look into the Quick Guide.

Please do not use chlorinated or aggressive cleaning products, as these can lead to corrosion of the stainless steel sheets and evaporator. !

Do not splash water directly on or into the device, as it can lead to electrical short circuits. We recommend that condenser cleaning be included in the company’s cleanup plan. This applies to the ready-to-use models, KPS 20, 40 and 60.

Show 8 more labels / short text on this page
> · > · > · > · > · > · > · >
Page 12 of the Gram KPS40 user manual — KPS 40
Page 12 · click to enlarge
Page 12

Service

The refrigeration system and the hermetic compressor do not require maintenance, but only cleaning.

Service - Continuation.

If your device is not working, check first if it wasn’t accidentally disconnected from the network or a fuse is broken.

KPS 20

If it is not possible to determine the reason for your device malfunction, contact GRAM’s technical department.

KPS 20 and 40: When you contact us, please tell us the device type and serial number (S/N) of the device. This information is provided by the nameplate (see adjacent images).

KPS 40

When removing covers or gaining access to electrical parts of the devices, unplug the power plug or disconnect the device from the circuit.

It is: not sufficient only to switch off the main switch on the device.

Show 5 more labels / short text on this page
> · > · Name of the type · > · Name of the type
Page 13 of the Gram KPS40 user manual — Service
Page 13 · click to enlarge
Page 13
Gram KPS40 — Service diagram (page 13)
Fig. 10 · Service

Climate class Volt Hz Watt Heating element Refrigerant gr

The nameplate is placed on the front of the shock cooler/freezer and can only be read by opening the control box. This may only be done by authorized personnel

KPS 60, 90, 120 and 180If you cannot access the device’s nameplate directly, please inform our technical department of its model and age.

Page 14 of the Gram KPS40 user manual — SUPPLEMENTARY PART
Page 14 · click to enlarge
Page 14

Duty cycles

Programming of user programs

How do you create your own user programs?

How do you create your own user programs? - Continuation.

If you want to design your own cycle, then use one of the following 3 types of cooling cycles.

The button and the display shows:

Soft Positive Cycle: Minimum room temperature of -5° C. and a minimum core temperature of +3° C.

The button and the display shows:

Negative cycle: Minimum room temperature of -25° C. and minimum core temperature of -18° C.

Hard positive cycle: 60% of the time is at a minimum room temperature of -25° C. The remaining time at a minimum room temperature of -5° C. The core temperature is set at +3° C. (e.g., for use in large pieces of meat.

Button to reach the settings of level 1 and adjust them to your requirements.

LEVEL 1

Plus Soft Ok Esc No

The settings are shown on this and next page:

!

To repeat the last cycle, press the START/STOP button.

Minus Ok Esc No

Return to the previous menu: Use the MENU button until you are back in the Start menu.

Regarding “core” in Level 2: This cycle runs under controlled core temperature until it has reached +3° C. in the soft or hard positive cycle or -18° C in the negative cycle.

Plus Hard Ok Esc No

Regarding “time” in Levels 2 and 3: This cycle is time controlled and runs until the set time has elapsed.

SUPPLEMENTARY PART

Show 5 more labels / short text on this page
> · Programmem Esc · Manual esc · > · START MENU Manual esc
Page 15 of the Gram KPS40 user manual — Duty cycles
Page 15 · click to enlarge
Page 15
Gram KPS40 — Duty cycles diagram (page 15)
Fig. 11 · Duty cycles

Move in the different cycles at level 1.

Select the time or room temperature and confirm your selection

-Button. If you want to save the program, do so before starting it (see next page).

Page 16 of the Gram KPS40 user manual — Note: Saved programs can also be overwritten. !
Page 16 · click to enlarge
Page 16

Programmes

Storage of user programs

User programs can be stored.

After programming its own cycle (see p.a.) 14-15) can be stored. The procedure is as follows:

Write the name of the program that is to be saved by using

Select the respective letters and numbers.

Press the button for 5 seconds and the display shows you the first free space. Available storage locations are also displayed in the display. e.g.

Then, confirm the button and move to the next position.

Then save the name.The display shows, for example:

Programme 02 - - -

Select the desired storage space.

If the memory space is not available, the program data stored here are displayed in the lowest line of the display.

Button to activate the saved cycle immediately.

Note: Saved programs can also be overwritten. !

Button to confirm the selected storage space. Leave the menu and the ad shows:

A - - -- - - Esc

ADDITIONAL PART Page 1616

Show 14 more labels / short text on this page
> · > · and · > · Hold on to the · > · With the · > · > · Name of the entity · > · > · > · >
Page 17 of the Gram KPS40 user manual — !
Page 17 · click to enlarge
Page 17

IFR programme

IFR adjusts the cycle to the characteristics of the food. IFR reduces the risk of surface freezing.

!

Insert the core temperature sensor correctly into the food (see p.4) and activate the IFR cycle. Now the temperatures are measured at 3 points, in the core, on the product surface and the room temperature.

From the main menu it is possible to start the IFR program directly.

Button for 5 seconds and the program starts immediately (see short guide).

Thus, surface ächenfrost that destroys the cell structures on the surface can be minimized.

This function can only be activated in the shock-cooling process and not in the flash frosting process, and requires correct placement of the core temperature sensor.

The button and the display shows:

button and it will display the following:

The program is started by the button.

ADDITIONAL PART Stage 17

Show 9 more labels / short text on this page
> · > · > · > · ESC programme · > · IFR Esc · > · With the
Page 18 of the Gram KPS40 user manual — IFR programme
Page 18 · click to enlarge
Page 18
Gram KPS40 — IFR programme diagram (page 18)
Fig. 12 · IFR programme

It is possible to use recommended programs that are preset and cannot be changed.

Select the selected “Preset Programs” button. The display shows:

Page 19 of the Gram KPS40 user manual — SUPPLEMENTARY PART
Page 19 · click to enlarge
Page 19

Use of own programs Pre-cooling

It is possible to save your own programs and use them later.

It is recommended to pre-cool the device before using a shock cooling or shock freeze process.

Button to choose your own programs. The display shows:

Button to select the desired menu.

Button until the display shows:

The button appears:

Then, check your selection.The display changes to:

UDVIDET BRUG

The buttons appear:

Button until the display shows:

Then, check your selection.

You can call up the desired own programs.

Activate the precooling cycle.

Button activate the selected program.

!

The pre-cooling can also be activated by the quick start function from the main menu (see here for more information). Quick Guide).

SUPPLEMENTARY PART

Show 22 more labels / short text on this page
> · > · > · ESC programme · Use them to use it. > · ESC programme · IFR Esc · > · With the · > · IFR Esc · User esc · > · Use them to use it. > · Cooling from Esc · > · With those · with the > · With the
Page 20 of the Gram KPS40 user manual — Storage programmes
Page 20 · click to enlarge
Page 20

Storage programmes

The devices can be used for storage for a short time.

Storage Programs – Continuation.

To defire the storage temperature, follow the following instructions.

To one negative Temperature to be set

Until display button:

Button for the desired menu.

for confirmation. The display is now as follows:

They will be in the display.

You can select the setpoint for storage temperature.

Then, check your selection.

To one Positive Storage temperature at

The button will confirm your selection.

Then choose the ones you use.

Button until the display shows:

ADDITIONAL PART SIDE 20

Show 16 more labels / short text on this page
> · > · Provide the · Negative Ok No · > · > · Press · With the · or Set Point Esc · Storage Esc · > · > · > · Medium · Positive Ok No
Page 21 of the Gram KPS40 user manual — !
Page 21 · click to enlarge
Page 21

Storage Programs – Continuation.

The display is now as follows:

Buttons you can select the fan speed.

But then you can confirm your choice. The display changes to:

Button start the storage program.

!

We do not recommend using the device for long storage processes, as it is not equipped with an automatic defrosting function.

Show 6 more labels / short text on this page
> · Speed Esc · > · With the · > · Storage Esc
Page 22 of the Gram KPS40 user manual — SUPPLEMENTARY PART
Page 22 · click to enlarge
Page 22

Fault codes

Overview

If your device has a defect or operational failure, error codes will appear in your display.

The table below provides information about error codes and how to fix them.

Error codes Reason How to fix the error

ALL High pressure The high-pressure switch is activated. • The shock cooler is too close to the wall (see installation).

  • Ask Gram’s Technical Department for Expert Help

ALL room Fuhler The room sensor is defective • A qualified technician is required.

  • The space sensor must be replaced.

ALL Verd Fuhler The evaporator sensor is defective • The problem may be an iced evaporator.

  • Ask Gram’s technical department for expert help.

ALL Kond Fuhler The capacitor sensor is defective. (only for ready-to-use devices)

  • A qualified technician is required.
  • The capacitor sensor must be replaced.

ALL Core Fuels The core temperature sensor is defective.

  • A qualified technician is required.
  • The sensor must be replaced.

All the Fuhler once. The core temperature sensor is not plugged in properly while a “core” program runs. The program automatically changes to a “time” control.

  • Place the KT feeler correctly or ignore the error message.
  • Important: If the KT sensor was not used correctly in quick start functions, a previous heating of it is required to avoid continuing with “storage” (display: Cons).

Space T High The room temperature in the storage program was higher than the setpoint plus 10°C. (Example: Setpoint +2°C, alarm from +12°C).

  • A qualified technician is required.

SUPPLEMENTARY PART

>

Page 23 of the Gram KPS40 user manual — SUPPLEMENTARY PART
Page 23 · click to enlarge
Page 23

Overview Error Codes - Continuation.

Error code Reason How to fix the error

ALL room T low The room temperature in the storage program was lower than the setpoint minus 10°C. (Example: Setpoint +2°C, alarm from -8°C).

  • A qualified technician is required.

ALL BlackOut The energy supply was interrupted.

  • When the energy supply is working again, you can read under ALARM how long the supply was interrupted and what the room temperature was.

All the door open - The equipment door is open. - The door contact switch is defective.

  • Close the device door.
  • If the error code continues to appear after the door is closed, a qualified technician will be required.

!

Please note the information about contacting GRAM Germany on the back of this user manual.

SUPPLEMENTARY PART

Page 24 of the Gram KPS40 user manual — SUPPLEMENTARY PART
Page 24 · click to enlarge
Page 24

Additional

Sterilization program Data Expression

This function is only available for devices with sterilization equipment – UV lamp (optional).

This function is only available if the device is equipped with a thermal printer (optional).

To complete the sterilization program

To select the printing program

Select the press

And move with the buttons.

Move with them

Buttons until the display shows:

Buttons until the display shows:

Then the button will be turned to:

Then the button will be turned to:

Printing data? Ok No

By pressing again the

The stored data is printed on the button. The data is then printed during subsequent cycles.

By pressing again the

The button starts sterilization. The display changes to:

Room xx °C Sterilisation

The button and selection “ok” will print all the saved cycles. !

But then stop the process.

The UV lamp is not included in the GRAM delivery range. !

If the door is opened, the process will be interrupted.

SUPPLEMENTARY PART

Show 12 more labels / short text on this page
> · > · Key and · Printing Esc · Sterilization Esc · > · > · Start? Ok No · > · > · > · With the
Page 25 of the Gram KPS40 user manual — SUPPLEMENTARY PART
Page 25 · click to enlarge
Page 25

Alerts

The controller stores all alarms.

Alarms – Continuation.

To get access to the stored alarms, press

If the alarm is still current, it appears in the displayIn operation” (in the example):

Then, turn and navigate with it.

A05 Room Fuhler In operation 16:30 10/02/09

Keys up to the display:

Press again the

Button for more information on how to fix the error. Example:

The button will see the last alarm. If no alarms have been stored, the display shows:

A05 Room Fuhler Call Service

You can call up all the stored alarms.

If alarms have been stored, the following display (example):

Press the several times.

Button to return to the main menu.

A05 Room Fuhler S 14:21 10/02/09

!

Alert information:

A_ _ =alert number, e.g. A05 is the fifth and last alarm which in this example defectively reports a space sensor. Space sensors = reports the error type, in our case a sensor defect. S = Alarm start. E = Alarm Stop. Present = Alarm constantly.

Button to get more information about this alarm. Thus, e.g. “E” for the end of alarm in this example:

A05 Room Fuhler E 16:30 10/02/09

See page 22 for an overview of the alarm codes, reasons and possible actions.

SUPPLEMENTARY PART

Show 13 more labels / short text on this page
> · > · The ones that are Alarm esc · > · > · > · With the keys · and · No Data Esc · > · >
Page 26 of the Gram KPS40 user manual — Keyboard lock service parameters
Page 26 · click to enlarge
Page 26

Keyboard lock service parameters

The keys can be blocked from unauthorized access.

The Service Parameters show the basic settings selected by GRAM.

Open the main menu (please see in the guide under “Quick Start”).

The service parameter level of the control is reserved for the service technician. This level is therefore protected by a password. Changes in parameters have a direct impact on the work and function of devices.

Button at the same time and a signal sounds.

The service parameter level looks like this:

Then press them.

simultaneously approx. 5 sec. until an “S” appears in the upper right corner of the display. The keys are now locked.

To revoke the ban,

Button again approx. 5 sec. until the “S” in the advertisement expires.

ADDITIONAL PART on page 26

Show 10 more labels / short text on this page
> · > · Press the . and > · > · and · Service esc · > · and
Page 27 of the Gram KPS40 user manual — DI1 DI2 FAN 0 1 80
Page 27 · click to enlarge
Page 27

Input/output values

This menu describes the input and output values, such as e.g. the current sensor temperatures, relay status etc.

Input/output values – continuation.

The values appear from the key and i.e. Table.

Navigate with them.

Adjustment buttons:

Buttons to scroll through the values.

Several times to return to the main menu.

Room -6°C sensor 15°C

Space and core temperature sensor values

Interior 6°C Outside -3°C

‘Inside’ surface temperature of foodstuffs. “Outside” room temperature.

evaporator -10° C. condenser 21° C

values of the evaporators and condenser temperatures. For devices with external cold, the display appears atCapacitor” “disab”.

C D FE FC L R A 1 0 0 1 1 0 0

1 = relay activated 0 = reel deactivated C = compressor D = thawing FE = evaporator fan FC = condenser fan L = sterilization equipment R = frame or floor heating A = alarm

Status of digital inputs and fan speed of evaporator fan DI 1 =Input door contact DI 2 =input high-pressure safety fan=evaporator fan speed (%)

DI1 DI2 FAN 0 1 80

This menu is used for error analysis. !

SUPPLEMENTARY PART

Show 7 more labels / short text on this page
>> > · Key and · > · Use the · Entrance/Exit Esc · > · Display description
Page 28 of the Gram KPS40 user manual — Disposal
Page 28 · click to enlarge
Page 28

Disposal

If the disused equipment has to be disposed of, this should take place in an environmentally correct and proper manner. Please observe appropriate laws and regulations on disposal.

If necessary, ask your local specialist trade or disposal company.

ADDITIONAL PART on page 28

>

Page 29 of the Gram KPS40 user manual — Disposal
Page 29 · click to enlarge
Page 29
Page 29 of the Gram KPS40 user manual — Disposal
Page 30 of the Gram KPS40 user manual — Technical service and spare parts department
Page 30 · click to enlarge
Page 30

Technical service and spare parts department

Technical assistance is available Mondays to Thursdays from 08:00 until 16:00 and Fridays from 8:00 a.m. to 14:30 p.m

Service numbersTelefon: 05066 / 60 46 46 Fax: 05066 / 60 46 49
Page 31 of the Gram KPS40 user manual — Quick Guide
Page 31 · click to enlarge
Page 31

Quick Guide

Control panel with keyboard and display

Fast key defrosting.

Fast key pre-cooling. Fast key IFR process. Also allows access to the main menu.

Fast key shock freezes.

Fast key shock cooling.

The display shows information about the ongoing process.

Key ... at least 5 seconds. Press – defrosting is started. This function can only be started if the evaporator is colder than 8°C.

Key... at least 5 seconds. Press – IFR process is started directly.

Key... at least 5 seconds. Press - shock frost process is started.* This function is not applicable to all shock coolers without a freezer function. (C models)

Key... at least 5 seconds. Press - shock cooling process is started.*

Key... at least 5 seconds. Press - the precooling cycle is started. At the end of the pre-cooling cycle (–25°C room temperature), the refrigerated goods should be introduced and the door closed. The desired process program must now selected.

Access to main menu: Press the button ... until the main menu is shown.

At the end of each cycle, the device will give an acoustic signal and automatically switch to storage mode. The storage temperature after shock cooling is +2°C and after shock freezing –22°C.

* Use of the core temperature sensor: When the core temperature sensor is placed and the short-dial key shock cooler or flash cooling, i.e. If the temperature is selected, then temperature-controlled cooling starts. If the core temperature sensor is not plugged in: A) the shock-cooling or frost process is automatically timed, or B if the core temperature sensor is colder than the required room temperature, the device changes to the storage program (indication “storage”).

Pressing “START/STOP” can interrupt this process. The sensor should be heated briefly in warm water. The shock cooling or -frost process can now be used as desired. The corresponding process is now activated.

Parameters for shock cooling without using the core temperature sensor: –5°C room temperature, 100% fan speed, 90 minutes cycle duration

Parameters for shock freeze without using the core temperature sensor: –25°C room temperature, 100% fan speed, 240 minutes cycle time.

See page 10 for more information about the use of quick start buttons...

Page 32 of the Gram KPS40 user manual — Shock freezes +70°/–18°C
Page 32 · click to enlarge
Page 32

Better food without stress

Shock-cooling or shock freeze programs can significantly help save food production costs. This allows working time to be used more effectively, the loss of weight of food produced can be minimized and unnecessary waste prevented. Without additional staff and without new investments in cooking technology, the kitchen output can be increased. Stressful situations during the output times or Unnecessary overtime in the case of additional baking tasks can be caused by the controlled shock cooling and/or refrigeration processes. Shock frost processes are prevented.

The KPS family

The KPS range of devices from GRAM has been developed to fully meet the legal requirements for cooling in a Cook & Chill process.

The capacities of the shock coolers (C models) range from 20 to 180 kg in 90 minutes and those of the flash freezers (S models) from 12 to 180kg in 240 minutes. Depending on the model, the devices are offered ready for plugging or to connect to central cold. For some devices, there are both options.

The KPS devices are not intended for continuous operation as storage equipment, since they do not have an automatic defrosting function.

Shock cooling +70°/+3°C

Only the rapid and controlled reduction of core temperatures of cooked meal components makes it possible to preserve natural food quality while preventing uncontrolled growth of harmful bacteria at temperatures between +60°C and +10°C.

GRAM's shock coolers allow the fastest possible passage through this temperature. A core temperature of +3°C in 90 minutes helps to preserve the vitamin content, appearance and taste of food.

Shock freezes +70°/–18°C

If the food is to be stored for a longer period of time, it must be frozen at least –18°C. By using a shock freezer, you can cool the food to a core temperature of –18°C according to HACCP guidelines within 4 hours. Shock freezing preserves the quality of processed and unprocessed foodstuffs, ensuring optimum product quality after thawing or regeneration.

Page 33 of the Gram KPS40 user manual — Better food without stress
Page 33 · click to enlarge
Page 33

Germany Gram Deutschland GmbH Im Kirchenfelde 1 D-31157 Sarstedt Tel: 05066 / 60 46 0 Fax: 0 5066 /60 46 49 e-mail: vertrieb@gram-commercial.com

www.gram-deutschland.de www.gram-deutschland.com

Nationwide service numbers: Tel. Product information: 05066 / 60 46 0 Tel. Technical information: 05066 / 60 46 46

Denmark Main site: Gram Commercial A/S Aage Grams Vej 1 DK-6500 Vojens Tel. +45 73 20 12 20 Fax: +4573 20 12 01 e-mail: info@gram-commercial.com

We about ourselves Gram Commercial A/S develops and produces refrigerators for professional kitchens. Headquartered in Vojens, Denmark, we belong to the global Japanese Hoshizaki Group of Companies that produce and distribute equipment for large kitchens. With our comprehensive dealer and service network, we offer our customers all over the world a competent local service.

! " #$# %%&'&( )*++,- " #

765041402

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Gram KPS40

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Gram KPS40

Be the first to ask — other owners or our team will answer.

Original document

Gram KPS40 manual PDF

33 pages·778 KB·Refrigeration and freezing·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…