kits 2 wires installation
AS-1220 SII
Instructions manual



O Audio door entry system with simplified installation (polarised 2 wire bus). O Up to 1 access door panel. O Up to 2 apartments (Necessary setting configuration, see page 33 & 37 for door panel & telephone). O Up to 4 telephones per installation. O Installations with one apartment, maximum 4 telephones. O Installations with two apartments, maximum 2 telephones per apartment. O 'Long' acoustic call acknowledgment signals. O 'Short' acoustic system busy signals (intercommunication). O Maximum distance between the door panel and the last telephone: 100m. O Maximum distance between power supply and telephone: 20m. O Maximum distance between the door panel and lock release: 20m. O Door opening timed at 3 seconds. O D.C. lock release. O Contact free auxiliary for activating auxiliary devices, do not switch voltage and current higher than
12Vcc/1A between C and NO door panel terminals. O T-1772VD telephone:
wPrivacy on audio communications. wIntercommunication function. wActivation auxiliary device function. wThree-position control for call volume: maximum, medium and off. wDifferent call tones which identify the call procedure: door panel and intercom.

O To make a call, the visitor should press over one of the push button ends, (if the door panel is configured
for 2 apartments, each side of push button will call to an apartment) as it is shown on the label of the push button. An acoustic 'long' tone will be heard confirming the call is in progress once the push button has been pressed. At this moment, the call will be received at the telephone(s) in the apartment. O If the door panel is configured for 2 apartments, the visitor can correct his call by pressing a push button
corresponding to a different apartment, in wich case the original call is cancelled. O The call tone lasts for 40 seconds. O To establish communication pick up the telephone handset. O The communication will last for 90 seconds or until the handset is replaced. O To open the door, press the door release push button during communication process: with one
press, the door release operates during 3 seconds. During activation, the audio will disappear with the door panel. O The description of the function push buttons is shown on page 36.


Solo abrepuertas de corriente contínua only d.c lock release
a. b. c. d. e. f . g. h. i . j . k. l .
Screws of fixation of the aluminium front (x2). Call push button for one or two apartments, (see page 39). Label push button. Wall attachment hook (x2). Wiring input hole. Telephone audio adjustment. Door panel audio adjustment. Installation terminals. Microphone. Speaker. JP2 configuration jumper for 1 or 2 apartments, (see page 33). Rainproof cover.


The upper part of the door panel should be placed at 1,65m. The surface door panel dimensions are the next:
W 96 mm. H 181 mm. D 20 mm.
The door panel has been designed to be placed under most of the environmental conditions. However it's recommended to take additional cautions, like the use of the supplied rainproof cover or the installation under a covered place.

With help of a plain screwdriver, remove the aluminium front making a light pressure in the door panel bottom holes, as shown on the picture.

lace the door panel. P
Face the door panel to the wall by placing the top at 1,65m. height and insert the installation wires through the cables entry.
Drill two holes of 6mm. diameter and insert the wallplugs. Fix the door panel with especified screws.
Connect the installation wires to the terminal connector, according to the installation diagrams.
The JP2 jumper is placed on the low left side of the door panel and it allows to select if the system is for 1 or 2 apartments.
JP2
System call to 1 apartment.
System call to 2 apartments.
Call push button (1 apartment):
Call push button (2 apartments):
Call to apartment 1.
Call to apartment 1.
Call to apartment 1.
Call to apartment 2.
If after starting the system it's considered that the audio volume isnt correct, proceed with the necessary adjustments as shown on the picture.


To costomize the push button label, insert a flat screwdriver to accede to the label, remove the push button front cover, see picture A & B . The label is now accesible to mark a text, see picture C . Replace the push button front cover, making a light pressure until listenning a click in both sides of the front cover, see picture D .
Finish the door panel assembly by replacing the aluminium front.

etail of the FA-133 power supply installation and technical features. D
The power supply must be installed in a dry and protected
3,5 x 25 DIN-7971
place It's recommended to protect the power supply by using a thermo-magnetic circuit breaker
To install the power supply directly on the wall, drill two
holes of Ø6mm. and insert the wallplugs Fix the transformer with the specified screws
3,5 x 25 DIN-7971
The power supply can be installed on a DIN 46277
guide simply pressing it To disassemble the power supply from the DIN guide, use a plain screwdriver to lever the flange as shown on the picture
. The FA- 133 power supply uses 3 units over DIN guide.
This device has been exclusively designed to be used on Golmar Kit audio AS-1220 SII. Golmar
will not be responsible of the possible damage caused for an improper use or when used for other purposes than the specified. Install the power supply according to your country rules.

3,5 x 25 DIN-7972
If the lock release will be installed in a metal door,
use a Ø3,5mm. drill and tap the hole In case of wood door, use a Ø3mm. drill
M 4 x 8
Technical features

. D
escription of the T-1772VD telephone

a. b. c. d. e.
Telephone handset Speaker grille Microphone hole
. Subjection .
hole Telephone cord connectors

. Door . .
aux. function f
f. g. h.
release push button/ Hook switch Intercommunication push button Volume control

With the handset picked up, without call reception or during a process of communication, a pulsation of 1 second activates the lock release or a pulsation of 3 seconds activates the auxiliary output.
With the handset picked up allows to establish an intercommunication between two points of the same apartment.
P+ P- + -
P+: P - : + : - :
Positive terminal, communication bus. Negative terminal, communication bus. Positive. Negative.

all volume control. C
The telephone allows to regulate the call volume with a maximum,
medium and off value. With the help of the switch of three positions placed in the right front of the telephone.
onfiguration jumper 'JP2'. C
JP2
Only if the door panel has been configurated for a system of 2 apartments
(see page 33), the JP2 configuration jumper of the telephone, allows to link the telephone of the apartment to a call push button of the door panel. The JP2 jumper is placed inside of the telephone.
Linked telephone to call push button 1 (apartment 1). System of 1 apartment, JP2 must be inserted.
JP2
Linked telephone to call push button 2 (apartment 2).
Call push button (1 apartment):
Call push button (2 apartments):
Call to apartment 1.
Call to apartment 1.
Call to apartment 1.
Call to apartment 2.
telephone must be inserted.
*Factory default.
The , incorporate as standard the intercommunication function T-1772VD telephone between two units of the same apartment.
To stablish an intercom communication lift the handset and press the intercom push button
on the calling telephone: acoustic tones will be reproduced on the handset confirming the call is in progress, the called telephone will receive the call. To establish communication, lift the handset of the called telephone.
The communication will last for 90 seconds or until the handset is replaced in any of two telephones.
If during an intercom communication a call is made from the door panel, acoustic tones will be heard on the handset of both telephones. To establish communication with the door panel, it must end the intercom and the visitor back to make the call from the door panel.

ix the telephone to the wall F

It is necessary to open the telephone for wiring and fixing
purposes To open the telephone, insert a plain screwdriver into the slots and gently lever as shown in the drawing

Avoid placing the telephone near sources of heat, in dusty locations or smoky environments The telephone can be fixed using an electrical embedding box or directly on the wall, as shown on the picture If the telephone will be installed directly over the wall, drill two holes of Ø6mm on the specified positions, using 6mm wall plugs and Ø3.5 x 25mm screws

ass the installation wires through the corresponding hole and connect them as shown on the installation diagrams lose the telephone as shown on the picture Once the telephone is closed, connect the handset using the telephone cord and put it on the cradle



+ P+ P- _ + P+ P- _ + P+ P- _
+ P+ P- _ + P+ P- _ + P+ P- _




onnection of an a.c. lock release by using TF-104 transformer Cand SAR-12/24 relay.

-Use an external relay for devices with higher consumption than 12Vd.c. / 1A.
C and NO c . -' ontact free auxiliary

O Nothing operates.
w Check the output power supply voltage between '–' and '+' is of 18Vd.c. Otherwise,
disconnect the power supply from the installation and measure again. If its correct now, it means there is a short circuit in the installation. Disconnect the power supply from the mains and check the installation. w Check the polarity wiring. w Check the JP2 configuration jumper of the door panel and the telephone/s are properly
configured, (see page 33 for the door panel and page 37 for the telephone). O Telephone don't receive calls.
w Check the output power supply voltage between '–' and '+' is of 18Vd.c. Otherwise,
disconnect the power supply from the installation and measure again. If its correct now, it means there is a short circuit in the installation. Disconnect the power supply from the mains and check the installation. w Check the polarity wiring. w Check the JP2 configuration jumper of the door panel and the telephone/s are properly
configured, (see page 33 for the door panel and page 37 for the telephone). O Inappropiate ring tone volume.
w Adjust the telephone call volume, (see page. 37). O Inappropiate audio level.
w Adjust the audio levels as shown on page 33. O Does not work the intercom.
w Remember that this function is only possible on installations with more than one telephone. w Check the intercom function steps have been realized correctly, (see page 37). O Door open function no operates.
w Remember that this function is only available with handset picked up, without call reception or
during a process of communication. w Check the lock release and its wiring.




Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis. Golmar reserves the right to make any modifications without prior notice.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.