Mounting and Operating Instructions

Flush-mounted outdoor station with call push button 1-gang

1271 65/66/67 Flush-mounted outdoor station with call push button 3-gang

1261 65/66/67 1272 65/66/67

1260 65/66/67

Page 2 of the Gira 1271 user manual
Page 2 · click to enlarge
Page 2

The flush-mounted outdoor station is part of the Gira door communication system.

The basic structure of a flush-mounted outdoor station is presented in the example of the flush-mounted outdoor station with call push button 3-gang:

3 4 5 6

Gira 1271 diagram (page 2)
Fig. 1

2 1 8 7

1 Door communication bus coupler

2 Audio connection cable

4 TX_44 frame bottom section

(not in scope of supply)

5 Door speaker top unit

6 TX_44 frame top section

(not in scope of supply)

7 Call push button covers

8 Call push button 3-gang

Device description · 3 Speech insert

Page 3 of the Gira 1271 user manual
Page 3 · click to enlarge
Page 3

Installation and mounting of electrical devices may only be carried out by a qualified electrician. Do not use the sealing rings included with the TX_44 frame when installing flush-mounted inserts.

The flush-mounted outdoor station is installed in two common flush-mounted panel boxes:

1. Connect the door communication bus coupler to
  • the 2-wire bus on the BUS terminals
  • if necessary, the wires of the additional supply to the "ZV" terminals
  • if necessary, the wires of a mechanical bell button to the "ET" terminals.

Deactivating call push button illumination

To deactivate the call push button illumi- nation continuously, remove the jumpers between BUS and ZV.

2. Insert the audio connection cable into one of the two system connectors of the bus coupler.
3. Guide the audio connection cable to the upper flush-mounted panel box and install the bus coupler in the lower flushmounted panel box.

Mounting

Page 4 of the Gira 1271 user manual
Page 4 · click to enlarge
Page 4
4. Insert the audio connection cable into one of the two system connectors of the speech insert.
5. Install the speech insert.
6. Place the bottom section of the TX_44 cover frame in place and attach the call push button and the speech insert to the flush-mounted inserts.
7. Clip on the frame top section and press in the Torx screws.

Once all of the devices (outdoor and home stations, control unit etc.) have been installed, you can start up the door com- munication system. Start-up is described in the system manual included with the control unit.

Initiating a call (ringing)

Press the call push button to trigger a call tone at the assigned home station. The button press is confirmed by an additional acknowledgement tone.

Switching light on/off (in conjunction with a switching actuator)

Press the call push button to switch on light or another device via an assigned switching actuator. The button press is confirmed by an additional acknowledge- ment tone.

Start-up · Operation

Page 5 of the Gira 1271 user manual
Page 5 · click to enlarge
Page 5

The volume can be set separately at each outdoor station. The volume setting must be made by two people.

1. Start programming mode at the control unit by pressing the "Systemprogr." button for 3 seconds until the yellow LED next to the button starts flashing.
Gira 1271 diagram (page 5)
Fig. 2
2. Briefly press a previously assigned call push button at the outdoor station .
3. The second person accepts the door call at the homestation (via receiver or speech button) and starts speaking.
4. Briefly press the call push button at the outdoor station again.

✓The volume changes when the button

is pressed during the voice connection. There are five volume levels in total. The next-highest volume is set with each button press. When the loudest level is reached, the next button press sets the quietest volume level.

5. End the voice connection. The most recently set volume level is saved in the outdoor station.
6. Exit programming mode at the control unit by briefly pressing the "Systemprogr." button.

Volume setting

Page 6 of the Gira 1271 user manual
Page 6 · click to enlarge
Page 6

Changing the label plates

T b 1o u .change the label pla tton cover can simpl Carefully lift up the c efully lift up t cover, e.g. with a screwdriver.cover, e.g. witha scr
3. Replace the call push button cover and press on it firmly.

Suitable label plates can be obtained with the optional Gira labelling software and the appropriate Gira labelling sheets.

Page 7 of the Gira 1271 user manual
Page 7 · click to enlarge
Page 7

The warranty is provided in accordance with statutory requirements via the spe- cialist trade.

Please submit or send faulty devices post- age paid together with an error description to your responsible salesperson (specialist trade/installation company/electrical spe- cialist trade).

They will forward the devices to the Gira Service Center.

Acceptance of guarantee

Page 8 of the Gira 1271 user manual
Page 8 · click to enlarge
Page 8

Gira Giersiepen GmbH & Co. KG Elektro-Installations- Systeme

10 41 03 70 22/11

Tel +49 (0) 21 95 / 602 - 0 Fax +49 (0) 21 95 / 602 - 191

www.gira.de

[email protected]

Postfach 1220 · 42461 Radevormwald Deutschland

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Gira 1271

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Gira 1271

Be the first to ask — other owners or our team will answer.

Original document

Gira 1271 manual PDF

8 pages·69 KB·Door bell·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…