Mounting Instructions and Commissioning for Qualified Electrician
Radio room temperature sensor with clock 1186 ..
41 05 06 08/05



On these instructions 3
The following symbols and marks are used in these instructions:
Method of functioning 3
✓Results of actions are identified by this check mark.
Installation 4
Installation and safety instructions 4
Mounting 4
Electrical connection 4
Improper use 4
Information on the economical use of the radio room temperature sensor is identified by this sign.
Teaching-in radio connection –LErn menu item 5
Deleting radio connection 5
Start-up (basic setting) 5
Information on facts which can lead to damage to persons or the device are identified by this sign.
Normal display (n) 6
Operating mode (b) 7
Sensor offset (o) 7
Heating optimisation (E) 7
Operation with radio controller
Gradient for heating optimisation (r) 8
Information on altered behaviour of the radio room temperature sensor when operating with the radio controller.
Summertime regulation (S) 8
Accuracy (U) 8
Software version (-) 8
Resetting all the settings (Reset) 8
The radio room temperature sensor is an electronic control device with an integrated clock for temperature and/or time-controlled single-room con- trol in residential or office buildings. The integrated radio transmitter pro- vides information on the current room temperature, the setpoint temperature and the temperature level currently used to the radio control- ler or directly to motor valve drives.
Technical data 9
Information on radio operation 9
Radio transmission 9
Acceptance of guarantee 10
The temperature is measured via an integrated detector.
Table of contents · On these instructions · Method of functioning

Installation and safety instructions
The radio room temperature sensor is mounted in flush-mounted boxes. Please observe the following points for optimal operation:
Installation and mounting of electrical devices may only be carried out by a qualified electrician.
The radio room temperature sensor is conceived for flush-type mounting. It consists of two units:
Connect the supply voltage (230 V, 50 Hz) to the terminals L and N.
Errors during connecting can lead to damage to the controlling device! No liability is accepted for damage caused by incorrect connection and/ or improper handling!
The top unit of the radio room temperature sensor is protected against unintentional placing on the flush-mounted unit of a Gira blind control system. When used incorrectly the radio room temperature sensor dis- plays the text FAIL flashing.

Teaching-in radio connection – LErn menu item
To assign radio motor valve drive(s) or a radio controller to the radio room temperature sensor, proceed as follows:
Changes in this menu should only be carried out by qualified persons since incorrect settings may result in proper control operation no longer being possible.

The parameters required for commissioning can be defined in the param- eter menu. The factory settings are preset to values which ensure proper operation even without adaptations in the parameter menu.
In order to change to the parameter menu:
✓During the teach-in process the LErn display flashes.
✓After approx. 5 seconds the radio room temperature sensor returns
The following parameters can be set or read:
directly to the normal display.
If a radio room temperature sensor is to be assigned several radio motor valve drives, first all valve drives must be switched into the teach mode before that teach-in process is started on the radio room temperature sensor.
The radio connection is deleted either
Start-up (basic setting) · Deleting radio connection

To improve clarity the respective character listed above is displayed in the top left of the display. The corresponding value is displayed on the right in the four large numerals.
This parameter is used to select the normal display of the radio room tem- perature sensor. This information is always displayed on the display whenever no menu has been selected and no holiday settings are active.

The respective parameter is opened for modification when the S button is pressed. The parameter value is displayed flashing.
When a parameter has been modified and confirmed with S, the parameter menu changes automatically to the next parameter.
The P button can be used at any time to return to the normal time pro- gram.


Modifications in the parameter menu are implemented immediately! The parameter is regarded as modified, irrespective of whether the menu is exited with S or P or whether the system returns automat- ically to the normal display after 1 minute.
During operation with the radio controller, the set value is permanently displayed with activated setpoint offset of the set value, regardless of the selected normal display. As soon as the setpoint offset is cancelled, the selected normal display appears again.
Normal display (n) · * Factory setting

This parameter allows individual selection of the function for the radio room temperature sensor. This defines the frequency of the radio trans- mission (convection heater, floor heating, radio controller).
During operation with the radio controller, the heating optimisation is inactive, as the radio controller specifies the course of the setpoint tem- perature curve over time.
Only for room heating
The heating optimisation function is only suitable for room heating. This function cannot be used for additional heaters.
The heating optimisation determines the temporal behaviour of the room on the basis of the past heating processes and calculates the required derivative action time which is necessary in order to reach the desired setpoint temperature on time.
The automatic heating optimization can be activated (On) and deactivated (OFF) here. If the heating optimisation is deactivated, switching is carried out exactly as specified in the time program.
The measured actual temperature can be displaced by ±3.0 Kelvin by means of this parameter. This correction can be used to compensate the measuring deviations which arise though the unfavourable placing of the radio room temperature sensor.
The heating optimisation is activated (On) in our works
The sensor offset is set to 0.0 Kelvin in our works.

Gradient for heating optimisation (r)
The current gradient which is used to calculate the derivative action time can be checked under this menu item. The time required to heat the room by one Kelvin (1K) is displayed here in minutes.
Here a correction value is entered at the factory, which ensures the great- est possible precision of the clock function.
The value represents the correction amount in seconds per day [s/d] and cannot be changed.
If the heat optimisation is activated, this gradient is always recalculated during a transition from a lowering phase to a comfort phase.
The heating optimisation is set to a gradient of 15 minutes per Kelvin [min/K] at our factory.
The currently installed software version can be interrogated here.
Here the sommertime regulation can be selected with which the switch- over time for summertime is calculated. The radio room temperature sen- sor differentiates between Central Europe and Great Britain.
When reporting technical problems, always specify the version of the software installed in the controlling device.
If the summertime function is deactivated (OFF), an automatic changeo- ver of the time is not carried out. Note that the time has to be changed over manually in this case.
Resetting all the settings (Reset)
You can delete all the parameter settings and programming and reset the device to the standard factory values:
✓The controlling device then carries out its display test and begins the
clock setting for repeated commissioning.

Information on radio operation
Radio transmission occurs on a non-exclusive transmission path, and interference cannot be excluded for this reason.
+ 10 to + 22 °C (comfort and lowering
The radio transmission is thus not suitable for security purposes, e.g. Emergency Stop, emergency call.
+ 5 to + 15 °C (frost protection temperature)
+ 10 to + 30 °C (individual temperature)
The transmission range of a radio transmitter (max. 100 m in free field) is dependent on the structural conditions of the building:
- 3 to + 3 K (setpoint offset during opera- tion with radio controller)
Wood, plaster, sheetrock approx. 90 %
Increment 0.5 K each
Brick, pressboard approx. 70 %
Reinforced concrete approx. 30 %
Metal, metal screens, aluminium cladding approx. 10 %
Operating principle as per EN 60730-1: 1.C (no limiter operating principle)
The radio room temperature sensor may be operated in all EU and EFTA countries.

We accept the guarantee in accordance with the corresponding legal pro- visions.
Please return the unit postage paid to our central service department giv- ing a brief description of the fault.
Gira Giersiepen GmbH & Co. KG Service Center Dahlienstraße 12 42477 Radevormwald, Germany
The CE sign is a free-trade mark intended solely for state authorities and does not contain any assurance of properties.
Gira Giersiepen GmbH & Co. KG Postfach 1220 42461 Radevormwald, Germany Tel.: 02195 / 602 - 0 Fax: 02195 / 602 - 339 Internet: www.gira.de
Acceptance of guarantee

Radio room temperature sensor with clock 1186 ..
Operating Instructions



On these instructions 3
The following symbols and marks are used in these instructions:
How the radio room temperature sensor functions 3
✓Results of actions are identified by this check mark.
Normal view in the display 4
Basic operation of the radio room temperature sensor 4
The individual displays and buttons 4
Starting up the radio room temperature sensor 5
Prolonging the heating phase (party function) 5
Information on the economical use of the radio room temperature sensor is identified by this sign.
Terminating the party function 5
Changing over to the lowering temperature (economy button) 6
Switching for brief periods to the lowering temperature 6
Operation with radio controller
Switching for longer periods to the lowering temperature 6
Information on altered behaviour of the radio room temperature sensor when operating with the radio controller.
Deactivating the lowering temperature 6
Setting the individual temperature 6
Deactivating the individual temperature 7
How the radio room temperature sensor functions
Locking buttons 7
Your radio room temperature sensor functions similarly to a time delay switch – at specific times which can be set, your heating system is regulated by the radio room temperature sensor to three temperatures which can be set.
Settings in the program menu 7
How to access the menu items in the program menu 7
Setting the date and time – Uhr (Clock) menu item 7
Modifying temperature steps - tEMP menu item 8
Modifying the time program – ProG menu item 9
Setting the holiday program – UrLb menu item 12
Activating/deactivating the anti-freeze function – FrSt menu item 13
Teaching-in radio connection –LErn menu item 14
Cleaning radio room temperature sensor 14
Table of contents · On these instructions

Normal view in the display
The individual displays and buttons

1 The current weekday is displayed here.
2 Symbol for the "Time program" operating mode.
3 Symbol for the "Comfort temperature" operating mode.
4 Symbol for the "Lowering temperature" operating mode.
5 Symbol for the "Anti-freeze temperature" operating mode.
6 The respective current operating mode is indicated here by means of triangles.
7 The ranges set for the comfort temperature in the time program are displayed here.
9 P. button
10 S. button
11 + or button, also called the party button.
Basic operation of the radio room temperature sensor
12 The time is displayed here. You can have this display changed by the installer to, for example, the temperature display.
The + and - buttons are used to set the values such as the time or the temperature.
The S button is used to confirm the set values.
13 Further information on the settings which you carry out is displayed here: e.g. H if you set the time.
If you do not press the S button after carrying out a setting, the display changes automatically back to the normal display 1 minute after a button has been pressed. Changes to the respective values are not accepted in this case.
The P button can be used at any time to return to the normal time program.

Starting up the radio room temperature sensor
Prolonging the heating phase (party function)
When the radio room temperature sensor is switched on for the first time, as well as after long deactivation periods, e.g. after a power failure, the radio room temperature sensor jumps automatically to the time input – the current data must be entered here. (You can edit these data later --> for details, please refer to „Setting the date and time – Uhr (Clock) menu item" on Page 7).
If necessary, you can extend or activate the comfort temperature – the so- called party function. This extension applies only once. After the extension has expired, the set time program is executed as usual.


You can extend or activate the heating phase by up to four hours. In addition, you can also repeat this extension as often as desired.
1 hour each time the button is pressed, and counting begins from the time the button is pressed. The period for which the party function is set flashes at the lower edge of the display.
You can have the time displayed in international 24 hour format (0H...23H) or in the English-speaking a.m. (12AM...11AM) and p.m. format (12PM...11PM). When you set the clock, the display begins with the 24-hour format, followed by the AM/PM format. Depending on the hour format which you confirm with S, the time is displayed in future in 24-hour format or in AM/PM format.
✓The display returns to the normal display
when no button is pressed for a few seconds. The period for which the party function is set flashes at the lower display margin.
✓The hour is set and the minute display
Terminating the party function
You can terminate the party function as follows:
✓The radio room temperature sensor returns to the normal time
program.
✓After the last confirmation with S, the system returns automatically
to the normal display.

Changing over to the lowering temperature (economy button)
Setting the individual temperature

You can change over to the lowering temperature for brief or long-term periods of absence by means of the economy button.
Switching for brief periods to the lowering temperature
During operation with the radio controller, a setpoint offset by ± 3 K is carried out via this menu item.
✓The radio room temperature sensor switches
over to the lowering temperature. The Lowering temperature mode is displayed.
You can set an individual temperature if the currently set temperature of the time program does not appear to be suitable.
The changeover is retained until the next switching time in the time program.
✓The currently set individual temperature is

displayed flashing.
Use this function during ventilation. Change back to the time program again after ventilation by pressing the P button.
Switching for longer periods to the lowering temperature
✓The radio room temperature sensor
returns to the normal display and regulates the set individual temperature until the next switching time in the time program. As long as the individual temperature is used as the setpoint input, no operating mode (Comfort, Lowering, Anti-freeze) is displayed, since none of the temperatures stored there is valid.
✓The radio room temperature sensor
permanently switches over to the lowering temperature. The Lowering temperature mode is displayed, the time program is no longer displayed.
This switchover is retained until you switch off the lowering temperature again.

If the S button is not pressed, the display returns to the normal display again after 5 seconds. Any changes to the setpoint temperature are not accepted in this case.
Deactivating the lowering temperature
You can deactivate the lowering temperature at any time:
✓The radio room temperature sensor returns to the normal time
program.

Settings in the program menu
You can change the following settings in the program menu:
Deactivating the individual temperature
You can deactivate the individual temperature at any time:
✓The radio room temperature sensor returns to the normal time
program.
*Menu item deactivated during operation with the radio controller.
How to access the menu items in the program menu
To prevent an accidental or unauthorised operation of the radio room temperature sensor, you can activate the button locking function in the normal view.
Irrespective of the setting you want to change you always access the desired menu item in the program menu as follows:
Activating button locking function
✓When the button locking function is active,
"-- --" appears in the display each time a button is pressed to signal that the desired operation has been denied.
Deactivating button locking function
Setting the date and time – Uhr (Clock) menu item
You can modify the date and time at any time.
✓During unlocking "-- --" appears in the display for 5 seconds. When the

button locking function is deactivated, the normal display appears again and the buttons can be released.
The clock is designed as a week time switch and continues to operate for least a four -hours in the case of a power failure. The changeover between summer and winter time is carried out automatically. The integrated calendar automatically takes leap years into account.
Locking buttons

To set the date and time:
Modifying the temperature steps – tEMP menu item


During operation with the radio controller, this function is deactivated. The setpoint temperature specification is carried out centrally on the radio controller.
You can modify the following temperature steps in the tEMP menu item.
You can have the time displayed in international 24 hour format or in the American format (AM/PM). Details are provided on Page 5.

✓The hour is set and the minute display
The anti-freeze temperature can be checked and set in the "Anti-freeze function" menu item. A change in the anti-freeze temperature in one of the menu items has a direct effect on the respective other menu item. Only one anti-freeze temperature is valid in the radio room temperature sensor.

If the date is already set correctly, you can exit the setting here by pressing the P button.
✓After the last confirmation with S, the system returns automatically
to the program menu.

To change the temperature steps:
Modifying the time program – ProG menu item

✓The temperature setting of the comfort
temperature is displayed flashing. In addition the operating mode is displayed at the right-hand display margin.
During operation with the radio controller, this function is deactivated. The time programs are managed centrally by the radio controller.
You can change the switching times of your radio room temperature sensor in the ProG menu item. 32 switching times are available. Each switching time specifies a point within a week at which a change between the comfort and lowering temperature takes place. You can change the switching times in steps of 10 minutes.
✓The display changes automatically to the next temperature step, the
lowering temperature.
The following time program is programmed at the factory.
✓After the last confirmation with S, the system returns automatically

to the program menu.
Aborting modifications to the temperature steps
These settings can be modified or extended as desired.
✓You return automatically to the program menu. The temperature step
Viewing the switching times
which you have opened last for editing is not saved.
✓The first switching time is displayed.

✓The switching times are displayed
chronologically, beginning at Monday 0.00 hours, rising to Sunday 23.50.
✓An empty switching time is offered at the
end of the list if at least one switching time is still available.

Modifying the switching time
Deleting the switching time
✓The switching time is opened for editing,
✓The switching time is deleted irrevocably and the chronologically next
the hour display flashes.
switching time is displayed.
Delete all switching times
With this function you can delete all stored switching times. This can, for example, be practical when a complete changeover of the time program is to be carried out and the deleting of individual program points is too time-consuming.

✓All switching times are deleted irreversibly and a blank program point
If a grouping of days is selected, a separate program point with the specified time and the temperature step is created for each selected day of the group. Renewed editing of the entire grouping is not possible - only the individual program items can be edited. It may therefore be practical in individual cases to delete all switching times and then enter a new grouping of days.

During this procedure the factory-programmed switching times are also deleted. These times can be restored via the Reset function.
✓After the last confirmation with S the modified switching time is
saved and the chronologically next switching time is displayed.

Inserting a new switching time
Aborting the settings at the time program
You can abort the modifications at the time program if no switching time is opened for processing.
✓You return automatically to the program menu. The currently active
switching time which was displayed for setting is not saved.
You can now carry out all the settings for a new switching time:
Further information on programming switching times
✓The new switching time is opened for
editing, the hour display flashes.

If you select a grouping of days, a separate switching time with the specified time and the temperature step is created for each selected day of the group. Renewed editing of the entire grouping is not possible - only the individual switching times can be edited. For this reason, it may be practical in individual cases to delete all switching times and then enter a new grouping of days.
✓After the last confirmation with S the modified switching time is
saved and the chronologically next switching time is displayed.

✓The month is displayed flashing.
Setting the holiday program – UrLb menu item

During operation with the radio controller, this function is deactivated. The holiday programs are managed centrally by the radio controller.
✓The operating mode is displayed flashing.
A holiday program is available in the UrLb menu item. You set the starting date and end date of your absence here. During this period the system regulates to a constant selectable temperature step. After the holiday period has expired the holiday program is deleted automatically so that it is not repeated every year.
10.Confirm with the S button.
✓After the last confirmation with S, the system returns automatically
to the program menu.
11.Press the P button and the radio room temperature sensor returns to the normal view.
Setting the holiday period
✓As soon as the internal date reaches the first

✓When the UrLb menu item is entered, the
holiday day at 0:00 hours, the temperature step is changed. The view in the display changes and displays the holiday end date.

display "--.--" appears if no holiday period has been defined yet.
✓The current date is entered automatically as
At low outside temperatures and longer periods of absence, you should have the holiday function end one day before the planned end of the holiday so that your flat is sufficiently pre-heated.
the holiday beginning. You can edit this date:
✓The month is displayed flashing.
Deleting the holiday period
✓The day begins to flash.
✓The radio room temperature sensor changes to the Program menu.
✓The display changes to the holiday end.

Activating/deactivating the anti-freeze function – FrSt menu item
✓On or OFF is displayed.

During operation with the radio controller, this function is deactivated. The anti-freeze function is managed centrally by the radio controller.
✓The anti-freeze function is activated or deactivated and the display
You can only permanently activate the anti-freeze function here.
return to the program menu.

✓After the anti-freeze function has been deactivated, the room
The anti-freeze function can only be set in operation between +5 °C and +15 °C.
temperature controller returns to continuous Lowering mode.
Proceed as follows in order to return to the normal time program:
flashing. In addition the corresponding operating mode is displayed flashing at the right-hand display margin.

A modification of the anti-freeze temperature also acts on the anti-freeze temperature set under "Modifying temperature steps" (refer to Page 8).

Teaching-in radio connection – LErn menu item
To assign radio motor valve drive(s) or a radio controller to the radio room temperature sensor, proceed as follows:
✓During the teach-in process the LErn display flashes.
✓After approx. 5 seconds the radio room temperature sensor returns
directly to the normal display.
If the radio room temperature sensor is to be assigned several radio motor valve drives, first all valve drives must be switched into the teach mode before that teach-in process is started on the radio room temperature sensor.
The radio connection is deleted either
Cleaning radio room temperature sensor
Deleting radio connection