Page 1 of the Gigaset elements Smoke user manual — GENERAL INFORMATION:
Page 1 · click to enlarge
Page 1

GENERAL INFORMATION:

The smoke alarm alerts you early and reliably to an accumulation of fi re smoke, and gives you and your family plenty of time to escape to safety.

This is of particular importance at night because when asleep we are not able to smell fi re smoke, and so are exposed to the toxic gases generated by fi res.

During this phase, the smoke alarm gives you a head start to escape the room safely.

Experience has shown that smoke alarms save lives.

In this respect, please also follow our instructions on using our product properly.

Delivered with the smoke alarm (including base) are this operating guide, the leafl et with important information, a permanently installed battery, a replaceable battery, 2 screws and dowels for attaching the alarm, and an adhesive pad.

Page 2 of the Gigaset elements Smoke user manual — = OPTIMAL PROTECTION
Page 2 · click to enlarge
Page 2

INSTALLATION LOCATION

The smoke alarm is fi tted to the ceiling of the room. Fitting it in the centre of the room gives the smoke alarm its optimum detection characteristics.

,JUDIFO

-JWJOHSPPN

To provide minimum protection, smoke alarms must be installed in bedrooms, children’s rooms and landings/hallways so you are woken up when an alarm is raised.

#BUI

In multi-storey buildings, at least one additional smoke alarm should be positioned in the hallway on every fl oor.

)BMMXBZ

,JUDIFO

If a smoke alarm is connected to a Gigaset elements base, the maximum range for DECT wireless transmission is 50 metres (indoor).

-JWJOHSPPN

$FMMBS

= MINIMUM PROTECTION

= OPTIMAL PROTECTION

= SPECIAL PROTECTION

Multi-room fl at · House

Page 3 of the Gigaset elements Smoke user manual — INSTALLATION POSITION FOR INCLINED ROOFS
Page 3 · click to enlarge
Page 3

INSTALLATION POSITION FOR INCLINED ROOFS

FOR INCLINED OR POINTED ROOFS For installation to inclined or pointed ceilings, and rooms with an inclined ceiling, smoke alarms should be installed at least 10 cm vertically underneath the highest point, and no more than 90 cm horizontally from the highest point. These distances also apply when multiple alarms are installed in one room. Install individual smoke alarms at appropriate distances from each other.

Gigaset elements Smoke — INSTALLATION POSITION FOR INCLINED ROOFS diagram (page 3)
Fig. 1

CEILING INSTALLATION When fi tting smoke alarms to the ceiling, keep a distance of at least 50 cm from a wall.

ANGLED CEILING In rooms having a ceiling at an angle greater than 7 degrees (corresponds to a height diff erence of about 50 cm over 4 m), smoke alarms should be positioned on the ceiling in the higher part of the room.

10cm · 90 cm

Page 4 of the Gigaset elements Smoke user manual — SAFETY INFORMATION - PLEASE NOTE:
Page 4 · click to enlarge
Page 4

SAFETY INFORMATION - PLEASE NOTE:

The smoke alarm is delivered with a permanently installed battery and a replaceable battery. No rechargeable batteries or mains adapters are required to provide power. Only insert the following batteries: Lithium Primary 3.0 Volt (CR2). Batteries with visible damage must be replaced.

MEDICAL DEVICES The functioning of medical devices can be aff ected. Bear in mind the technical conditions of the environment in question (such as a doctor’s surgery).

If you use medical devices (such as pacemakers), please fi nd out from the device manufacturer the extent to which the devices in question are immune to external, high-frequency energy.

Page 5 of the Gigaset elements Smoke user manual — SAFETY INFORMATION - PLEASE NOTE:
Page 5 · click to enlarge
Page 5

SAFETY INFORMATION - PLEASE NOTE:

DO NOT SPRAY OR PAINT OVER AN ALARM Smoke alarms may not be coated with paint.

INSTALLATION IN ROOF GABLES Installation in roof gables is only permitted when they are fi tted in line with “Installation position for inclined roofs”.

Page 6 of the Gigaset elements Smoke user manual — SAFETY INFORMATION - PLEASE NOTE:
Page 6 · click to enlarge
Page 6

SAFETY INFORMATION - PLEASE NOTE:

DISTANCE FROM LIGHTS Keep a distance of at least 50 cm between lights and smoke alarm installation position.

FOR INDOOR USE ONLY Smoke alarms are only permitted for indoor use.

People have a reduced perception of fi re and fi re smoke especially when asleep. Smoke alarms provide an early warning so that speedy reactions are possible. Smoke alarms do not provide protection from material damage.

Page 7 of the Gigaset elements Smoke user manual — SAFETY INFORMATION - PLEASE NOTE:
Page 7 · click to enlarge
Page 7

SAFETY INFORMATION - PLEASE NOTE:

BEAR IN MIND THE ENVIRONMENT Do not use the devices in potentially explosive environments, such as paint shops.

DISPOSAL Do not throw (rechargeable) batteries out with household waste. For this, observe local waste disposal regulations (available from your local authority).

In Germany: Dispose of these in the green “Gemeinsame Rücknahmesystem Batterien” (Collective return system for batteries) boxes provided at specialist retailers.

Page 8 of the Gigaset elements Smoke user manual — SAFETY INFORMATION - PLEASE NOTE:
Page 8 · click to enlarge
Page 8

SAFETY INFORMATION - PLEASE NOTE:

All electrical and electronic devices must be disposed of at local authority sites (separate from general household waste).

If a product displays the symbol of a crossed-out rubbish bin, the product is subject to European Directive 2012/19/EU.

Proper disposal and separate collection of used equipment help to prevent potential harm to human health and the environment. They are prerequisites for the reuse and recycling of used electrical and electronic equipment.

Consult your local authority or waste disposal fi rm for more comprehensive information on disposal of your old devices.

Page 9 of the Gigaset elements Smoke user manual — SAFETY INFORMATION - PLEASE NOTE:
Page 9 · click to enlarge
Page 9

SMOKE ALARMS MAY NOT BE AFFIXED AT THE FOLLOWING PLACES:

DISTANCE FROM WATER VAPOUR Rooms in which high levels of water vapour are generated under normal conditions (e.g. kitchen, bathroom/toilet)

DISTANCE FROM FIREPLACES Near fi replaces and open fl ues

TEMPERATURE RANGE Rooms having temperatures lower than -10°C or higher than +60°C

DO NOT POSITION IN DRAUGHTS Near ventilation shafts (e.g. of air-conditioning or recirculation air system)

Page 10 of the Gigaset elements Smoke user manual — INSTALLATION AND USE
Page 10 · click to enlarge
Page 10
Gigaset elements Smoke — INSTALLATION AND USE diagram (page 10)
Fig. 2

INSTALLATION AND USE

1. Insert the battery. Note the correct polarity.
2. Register smoke to your base station.

Look for the small red registration button. Bring smoke into the immediate vicinity

Gigaset elements Smoke — INSTALLATION AND USE diagram (page 10)
Fig. 3

of your base. Start the Gigaset elements app. In the app, open the system overview

, and select "Add + smoke”, then follow the instructions on the screen. Smoke is then connected to Gigaset elements

and is shown in the system overview of the app.

Page 11 of the Gigaset elements Smoke user manual — INSTALLATION AND USE
Page 11 · click to enlarge
Page 11
3. Decide on the right location for smoke:

Within reach of base (max. 50 m). If possible, in the middle of the room, with a minimum

distance of 50 cm away from live wires. Check that no live wires run across the installation

location and keep a minimum distance of 50 cm from walls and lights.

4. Ensure that the dust created from drilling cannot dirty the smoke alarm.

Use adhesive pads for installation if you do not want to

drill. For information on installing with adhesive pads see: "Optional accessory"

Page 12 of the Gigaset elements Smoke user manual — INSTALLATION AND USE
Page 12 · click to enlarge
Page 12
5. Use a 6 mm bit to drill two holes in the ceiling.

You can use the lower part / base of the smoke alarm

as a template.

6. Insert the dowels provided into the drill holes.
7. Use the screws supplied to attach the base of the alarm to the ceiling.
8. Place the face of the alarm onto the lower part and lock it into place by turning it clockwise.
9. The smoke alarm is activated automatically by locking it into the base.
Page 13 of the Gigaset elements Smoke user manual — INSTALLATION AND USE
Page 13 · click to enlarge
Page 13
10. Perform a function test. To do this, press the face of the alarm for at least 1 second.
11. When the signal sounds, the function test is successful and the smoke alarm is working correctly.

All-is-good

Page 14 of the Gigaset elements Smoke user manual — SYSTEM AND ALARM SIGNALS
Page 14 · click to enlarge
Page 14

SYSTEM AND ALARM SIGNALS

Acoustic signal Red LED Function / Meaning

No sound Flashes every

344 seconds Normal state, automatic self-test

every 0.5 seconds

0.5 seconds Alarm state

every 40 seconds OFF Battery change display, please renew the alarm

3 short signal sounds every 40 seconds OFF Fault/dirt, please renew the alarm

No sound Flashes every

10 seconds Alarm muting

Flashes every 0.5 seconds whilst the face of the alarm is

Show 6 more labels / short text on this page
Loud intermittent sound · Flashes every · Short signal sound · Loud intermittent sound · Function test · pressed
Page 15 of the Gigaset elements Smoke user manual — NOTE!
Page 15 · click to enlarge
Page 15

FUNCTION AND ALARM TEST

1. Perform a visual inspection of the smoke alarm. In so doing, check:

The smoke alarm is in place The smoke inlet openings for coarse dirt (dust, paint) The smoke alarm for mechanical damage

A damaged smoke alarm must be replaced immediately.

2. Perform a function test. To do this, press the face of the alarm for at least 1 second. The signal sounds if the function test is successful.

The smoke alarm is working correctly.

3. DIN 14676 stipulates that smoke alarms must be replaced with new ones after 10 years at the latest. After every function test, alarm muting is enabled automatically for approx. 10 minutes.

NOTE!

Alarm muting has no function when the smoke alarm is tested with test aerosol.

Page 16 of the Gigaset elements Smoke user manual — CARE
Page 16 · click to enlarge
Page 16

MAINTENANCE

The state building codes in some federal states stipulate that owners of houses and fl ats are responsible for ensuring that smoke alarms are installed and function correctly. Maintenance must be performed at least once a year and comprises (according to DIN 14676) a visual inspection and function/alarm test. A function test must be performed following a longer period of absence, but no later than after a year.

REPLACEMENT DATE ON THE LABEL

Replace all smoke alarms after 10 years at the latest. The recommended date for replacement is on the label in format month/year. Smoke alarms can be stored for a maximum period of 2 years before being used.

CARE

Wipe the device with a damp or antistatic cloth. Do not use solvents or microfi bre cloths. Never use a dry cloth as this can cause static charging.

Page 17 of the Gigaset elements Smoke user manual — BATTERY FAULT MUTING
Page 17 · click to enlarge
Page 17

ALARM MUTING

When an alarm is raised, alarm muting can be activated by pressing the face of the alarm. This reduces the response sensitivity of the alarm / increases its activation threshold. The alarm is muted if the smoke concentration in the smoke chamber is below the increased activation threshold after the face of the alarm is pressed. If the smoke concentration is still above the increased activation threshold, muting is not activated until the smoke concentration drops below the increased activation threshold. The smoke alarm is muted. The smoke alarm returns to normal mode after about 10 minutes.

Gigaset elements Smoke — ALARM MUTING diagram (page 17)
Fig. 4

BATTERY FAULT MUTING

This function is especially useful at night. Press the test button on the face of the alarm to suppress the fault signal for about 8 hours when a battery fault occurs. After this time, the battery fault signal is sounded again and you are reminded to replace the smoke alarm.

the face

Page 18 of the Gigaset elements Smoke user manual — OPTIONAL ACCESSORY
Page 18 · click to enlarge
Page 18

OPTIONAL ACCESSORY

CNBOP-PIB APPROVED ADHESIVE PAD The smoke alarm base can be attached to the ceiling using the screws and dowels supplied or with the dual-sided adhesive pad. For order request, please contact the Gigaset customer service www.gigaset.com/service

When using the adhesive pad to fi t the alarm, note the condition of the surface in question to guarantee secure adhesion of the smoke alarm. Best possible adhesive force is only attained with clean surfaces. Before using the adhesive pad, carefully check that the condition of the surface used is suitable for permanent bearing and bonding of the weight (carry out test adhesion as required).

For installation, pull the protective fi lm from one side of the adhesive pad and stick it onto the middle of the base of the smoke alarm. Next, remove the protective fi lm on the other side and press the base fi rmly to attach it to the ceiling. Then continue with the installation as described in section “Installation and use”.

Page 19 of the Gigaset elements Smoke user manual — ANTI-TAMPER SEAL OR SAFETY SCREW
Page 19 · click to enlarge
Page 19

INFORMATION ON THE ADHESIVE STRIPS

Only stick the sensors onto clean, dry, grease-free surfaces which are as smooth and

sturdy as possible. The optimal adhesive strength is attained after about 48 hours. The adhesive strips are intended for one-time use only. Only use the adhesive strips provided. Gigaset Communications GmbH assumes no liability for potential damage to surfaces caused by sticking on, setting up, installing and removing Gigaset elements sensors and actuators.

ANTI-TAMPER SEAL OR SAFETY SCREW

A plastic anti-tamper seal can be affi xed to the smoke alarm to prevent unauthorised removal.

Instead of this seal, a safety screw can be fi tted to prevent unauthorised removal of the smoke alarm.

The seal and screw are not included in the delivery and can be ordered separately. Please contact the Gigaset customer service www.gigaset.com/service

Page 20 of the Gigaset elements Smoke user manual — INFORMATION ON THE ADHESIVE STRIPS
Page 20 · click to enlarge
Page 20
Page 20 of the Gigaset elements Smoke user manual — INFORMATION ON THE ADHESIVE STRIPS
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Gigaset elements Smoke

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Gigaset elements Smoke

Be the first to ask — other owners or our team will answer.

Original document

Gigaset elements Smoke manual PDF

112 pages·850 KB·Security·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…