Gallagher M150

74 pages·3.2 MB·Miscellaneous·PDF·ENJA
Gallagher M150
Table of Contents 27 sections FENCE ENERGIZER M150 / M200 / M300 / M500 · - ENG · - NED · - FRA · … ShowHide
Page 1 of the Gallagher M150 user manual — - FRA
Page 1 · click to enlarge
Page 1

FENCE ENERGIZER M150 / M200 / M300 / M500

- ENG

- NED

- FRA

- DEU

- DAN

- ESP

- SVE

- ITA

Show 7 more labels / short text on this page
Instructions · Installatie instucties · Betriebsanleitung · Monteringsvejledning · Instrucciones · Monteringsinstrucktioner · Istruzioni per l’installazione
Page 2 of the Gallagher M150 user manual — FENCE ENERGIZER M150 / M200 / M300 / M500
Page 2 · click to enlarge
Page 2

PUBLISHED BY Gallagher Group Limited 181 Kahikatea Drive, Private Bag 3026 Hamilton, New Zealand

www.gallagherams.com Copyright© Gallagher Group Limited 2008 All rights reserved. Patents pending.

Gallagher M150 / M200 / M300 / M500 Mains Powered Energizer User Manual

3E0682 - EdiƟ on 8 - November 2012

DISCLAIMER: Whilst every eff ort has been made to ensure accuracy, neither Gallagher Group Limited nor any employee of the company shall be liable on any ground whatsoever to any party in respect of decisions or acƟ ons they may make as a result of using this informaƟ on. In accordance with the Gallagher policy of conƟ nuing development, design and specifi caƟ ons are subject to change without noƟ ce. Developed and manufactured by Gallagher Group Limited, and ISO 9001 2000 CerƟ fi ed Supplier.

Page 3 of the Gallagher M150 user manual — FENCE ENERGIZER M150 / M200 / M300 / M500
Page 3 · click to enlarge
Page 3
Page 3 of the Gallagher M150 user manual — FENCE ENERGIZER M150 / M200 / M300 / M500
Page 4 of the Gallagher M150 user manual — FENCE ENERGIZER M150 / M200 / M300 / M500
Page 4 · click to enlarge
Page 4
Page 4 of the Gallagher M150 user manual — FENCE ENERGIZER M150 / M200 / M300 / M500
Page 5 of the Gallagher M150 user manual — Important Informa Ɵ on IMPORTANT INFORMATION
Page 5 · click to enlarge
Page 5

Important Informa Ɵ on IMPORTANT INFORMATION

WARNING: Read all instruc Ɵ ons

  • Do NOT touch the fence with the head, mouth, neck or torso. Do not climb over, through or under a mul Ɵ -wire electric fence. Use a gate or a specially designed crossing point.
  • Do NOT become entangled in the fence. Avoid electric fence construc Ɵ ons that are likely to lead to the entanglement of animals or persons.
  • Energizer must be installed in a shelter and the supply cord must not be handled when the ambient temperature is below +5 deg C.
  • Ensure the Energizer is fully protected from rain, condensa Ɵ on and other sources of moisture.
  • Do not mount in places exposed to heat sources (e.g. a sun heated metal wall.)
  • Ensure the Energizer has adequate ven Ɵ la Ɵ on.
  • Electric animal fences shall be installed and operated so that they cause no electrical hazard to persons, animals or their surroundings.
  • It is recommended that, in all areas where there is a likely presence of unsupervised children who will be unaware of the dangers of electric fencing, that a suitably rated current limi Ɵ ng device having a resistance of not less than 500 ohms be connected between the energizer and the electric fence in this area.
  • The appliance is not intended for use by young children or infi rm persons without supervision.
  • Young children should be supervised to ensure that they do not play with the appliance.
  • Do not place combus Ɵ ble materials near the fence or energizer connec Ɵ ons. In Ɵ mes of extreme fi re risk, disconnect energizer.
  • Regularly inspect the supply cord and energizer for any damage. If found damaged in any way, immediately cease use of the energizer and return it to a Gallagher Authorised Service Centre for repair in order to avoid a hazard.
  • Refer servicing to a Gallagher Authorised Service Centre.
  • Check your local council for specifi c regula Ɵ ons.
  • Energizers with a Standby mode may turn on or off without warning. The energizer must be disconnected from the mains supply if it needs to be rendered fully inopera Ɵ ve.
  • An electric animal fence shall not be supplied from two separate energizers or from independent fence circuits of the same energizer.
  • For any two separate electric animal fences, each supplied from a separate energizer independently Ɵ med, the distance between the wires of the two electric animal fences shall be at least 2.5m. If this gap is to be closed, this shall be eff ected by means of electrically non-conduc Ɵ ve material or an isolated metal barrier.
  • Do not connect two Energizers to the same earth system.
  • Barbed wire or razor wire shall not be electrifi ed by an energizer.
  • A non-electrifi ed fence incorpora Ɵ ng barbed wire or razor wire may be used to support one or more off -set electrifi ed wires of an electric animal fence. The suppor Ɵ ng devices for the electrifi ed wires shall be constructed so as to ensure that these wires are posi Ɵ oned at a minimum distance of 150 mm from the ver Ɵ cal plane of the non-electrifi ed wires. The barbed wire and razor wire shall be earthed at regular intervals.
  • Follow the energizer manufacturer’s recommenda Ɵ ons regarding earthing.
  • The energizer earth electrode should penetrate the ground to a depth of at least 1 m (3 Ō ) and not be within 10 m (33 Ō ) of any power, telecommunica Ɵ ons or other system.
  • Use high voltage lead-out cable in buildings to eff ec Ɵ vely insulate from the earthed structural parts of the building and where soil could corrode exposed galvanized wire. Do not use household electrical cable.
  • Connec Ɵ ng leads that are run underground shall be run in conduit of insula Ɵ ng material or else insulated high voltage lead-out cable shall be used. Care must be taken to avoid damage to the connec Ɵ ng leads due to the eff ects of animal hooves or tractor wheels sinking into the ground.
  • Connec Ɵ ng leads shall not be installed in the same conduit as the mains supply wiring, communica Ɵ on cables or data cables.
  • Connec Ɵ ng leads and electric animal fence wires shall not cross above overhead power or communica Ɵ on lines.
  • If connected to a mains power circuit that doesn’t have a Residual Current Device (RCD), then a plug-in RCD should always be used.
  • Crossings with overhead power lines shall be avoided wherever possible. If such a crossing cannot be avoided it shall be made underneath the power line and as nearly as possible at right angles to it.
  • If connec Ɵ ng leads and electric animal fence wires are installed near an overhead power line, the clearances shall not be less than those shown in the table following.
Page 6 of the Gallagher M150 user manual — Important Informa Ɵ on IMPORTANT INFORMATION
Page 6 · click to enlarge
Page 6

Minimum clearances from power lines for electric animal fences

Power line Voltage VClearance m Less than or equal to 1 000 Greater than 1 000 and less than or equal to 33 000 Greater than 33 0003 4 8
  • If connec Ɵ ng leads and electric animal fence wires are installed near an overhead power line, their height above the ground shall not exceed 3 m This height applies either side of the orthogonal projec Ɵ on of the outermost conductors of the power line on the ground surface, for a distance of:-
  • - 2 m for power lines opera Ɵ ng at a nominal voltage not exceeding 1 000 V; - 15 m for power lines opera Ɵ ng at a nominal voltage exceeding 1 000 V.
  • Electric animal fences intended for deterring birds, household pet containment or training animals such as cows need only be supplied from low output energizers to obtain sa Ɵ sfactory and safe performance.
  • In electric animal fences intended for deterring birds from roos Ɵ ng on buildings, no electric fence wire shall be connected to the energizer earth electrode. A warning sign shall be fi Ʃ ed to every point where persons may gain ready access to the conductors.
  • Fence wiring should be installed well away from any telephone or telegraph line or radio aerial.
  • Where an electric animal fence crosses a public pathway, a non-electrifi ed gate shall be incorporated in the electric animal fence at that point or a crossing by means of s Ɵ les shall be provided. At any such crossing, the adjacent electrifi ed wires shall carry warning signs.
  • Any part of an electric animal fence that is installed along a public road or pathway shall be iden Ɵ fi ed by electric fence warning signs (G6020) at regular intervals that are securely fastened to the fence posts or fi rmly clamped to the fence wires.
  • The size of the warning sign shall be at least 100mm x 200mm.
  • The background colour of both sides of the warning sign shall be yellow. The inscrip Ɵ on on the sign shall be black and shall be either:
Gallagher M150 — Important Informa Ɵ on IMPORTANT INFORMATION diagram (page 6)
Fig. 1 · Important Informa Ɵ on IMPORTANT INFORMATION
- the substance of “CAUTIONElectric Animal Fence” or, - the symbol shown:
  • The inscrip Ɵ on shall be indelible, inscribed on both sides of the warning sign and have a height of at least 25mm.
  • Ensure that all mains operated, ancillary equipment connected to the electric animal fence circuit provides a degree of isola Ɵ on between the fence circuit and the supply mains equivalent to that provided by the energizer.
  • Protec Ɵ on from the weather shall be provided for the ancillary equipment unless this equipment is cer Ɵ fi ed by the manufacturer as being suitable for use outdoors, and is of a type with a minimum degree of protec Ɵ on IPX4. This energizer complies with interna Ɵ onal safety regula Ɵ ons and is manufactured to interna Ɵ onal standards. Gallagher reserves the right to make changes without no Ɵ ce to any product specifi ca Ɵ on to improve reliability, func Ɵ on or design. E & OE. The author thanks the Interna Ɵ onal Electrotechnical Commission (IEC) for permission to reproduce Informa Ɵ on from its Interna Ɵ onal Publica Ɵ on 60335-2-76 ed.2.0 (2002). All such extracts are copyright of IEC, Geneva, Switzerland. All rights reserved. Further informa Ɵ on on the IEC is available from <a href="http://www.iec.ch" rel="nofollow noopener" target="_blank">www.iec.ch</a> IEC has no responsibility for the placement and context in which the extracts and contents are reproduced by the author, nor is IEC in any way responsible for the other content or accuracy therein.

SERVICE OF DOUBLE-INSULATED APPLIANCES In a double-insulated controller, two systems of insulaƟ on are provided instead of grounding. No equipment grounding means is provided in the supply cord of a double-insulated controller, nor should a means for equipment grounding be added to the controller. Servicing a double-insulated controller requires extreme care and knowledge of the system, and should be done only by qualifi ed service personnel. Replacement parts of a double insulated controller must be idenƟ cal to the parts they replace. A double insulated controller is marked with the words “DOUBLE INSULATION” or “DOUBLE INSULATED”. The symbol for double insulaƟ on may also be marked on the appliance.

Page 7 of the Gallagher M150 user manual — Output voltage bargraph
Page 7 · click to enlarge
Page 7

UNDERSTANDING YOUR ENERGIZER

Power on: Indicates normal opera Ɵ on

Output voltage bar graphQuick indica Ɵ on of the voltage at the energizer
Gallagher M150 — Power on: Indicates normal opera Ɵ on diagram (page 7)
Fig. 2 · Power on: Indicates normal opera Ɵ on

Earth Terminal: Connects to Earth

Output Terminal: Connects to Fence

M500: This energizer complies with the requirements for a Ɵ me delayed electric fence energizer with a Ɵ me delay of 15 seconds.

Power On Light

Green light constant- Normal operaƟ on

Output voltage bargraph

The output voltage bargraph will pulse with every energizer pulse. Each colour segment gives an approximate indicaƟ on of the fence performance. The bargraph is read in the following manner:

Green SegmentsYour fence is performing well. No aƩ enƟ on is required. Yellow SegmentsYour fence is under some load but is sƟ ll delivering an eff ecƟ ve shock. Red SegmentsYour fence is under heavy load and requires maintenance.

Use this bar graph for quick indicaƟ on of your energizer and Fence performance.

Green Yellow Red

Page 8 of the Gallagher M150 user manual — b
Page 8 · click to enlarge
Page 8
Gallagher M150 — Step 1. Install the energizer diagram (page 8)
Fig. 3 · Step 1. Install the energizer
Gallagher M150 — Step 1. Install the energizer diagram (page 8)
Fig. 4 · Step 1. Install the energizer

Step 1. Install the energizer

Mount the energizer on a wall, under cover or inside, out of reach of children. Install where there is no risk of the energizer incurring fi re or mechanical damage and if possible away from heavy electrical equipment eg. pumps or other items that may cause electrical interference.

Gallagher M150 — Step 1. Install the energizer diagram (page 8)
Fig. 5 · Step 1. Install the energizer

a) Using the template on the back page, drill 2 x 4mm (5/32”) holes (A & B).

b) Fix the screws provided into the wall leaving the head of the screw about 3mm (1/8”) out from the wall.

a

Gallagher M150 — a diagram (page 8)
Fig. 6 · a

c) Place the energizer over and slide down onto the mounƟ ng screws.

b

Gallagher M150 — b diagram (page 8)
Fig. 7 · b

5 Wire Ɵ ghtener

9 Cut out switch

Show 10 more labels / short text on this page
1 Energizer · 2 Earth stake · 6 Warning sign · 10 Joint clamps · 3 Strain insulator · 7 Earth (Green) · 11 Strain post · 4 Post insulator · 8 Live (Red) · 12 Line post
Page 9 of the Gallagher M150 user manual — G8790
Page 9 · click to enlarge
Page 9

Step 2. Connect to earth (ground) system

a) Using Underground Cable (G6270) remove 5cm (2”) of plasƟ c coaƟ ng from one end of the cable and connect to the green terminal on the energizer.

b) AƩ ach the cable to the earth system by removing 10cm (4”) of insulaƟ on from the cable at each Earth Stake (G8790), then clamp the exposed wire to each stake using an Earth Clamp (G8760).

c) Tighten the clamp.

Step 3. Connect the fence

a) Connect the energizer’s red output (

) terminal to the fence using Underground Cable (G6270).

b) AƩ ach the other end of the cable to the fence using a Joint Clamp (G603).

Step 4. Turn the energizer on

a) Plug the energizer into a power outlet and switch ON.

b) Check that the Power On LED on the front of the energizer is green.

Find a locaƟ on for your earth system that is permanently damp, has high ferƟ lity or salinity and is away from dairy sheds. Install the earth system at least 10m (33Ō ) from any power supply earth peg, underground telephone or power cable.

Gallagher M150 — Step 4. Turn the energizer on diagram (page 9)
Fig. 8 · Step 4. Turn the energizer on

G8760

The best construcƟ on is 2m (61/2Ō ) long galvanised stakes G8790 or Super Earth Kits G8800, 3m (10Ō ) apart, connected to the energizer by high quality Lead-out cable G6270. Do not use materials that rust. (Use G6272 if the earth system is over 100m (300Ō ) from the energizer).

G8790

Page 10 of the Gallagher M150 user manual — An earth wire return system (for areas with poor earthing)
Page 10 · click to enlarge
Page 10
Gallagher M150 — HOW TO INSTALL AN EARTH Έ GROUND Ή SYSTEM diagram (page 10)
Fig. 9

HOW TO INSTALL AN EARTH Έ GROUND Ή SYSTEM

Improperly earthed energizers can cause barns, gates etc to become hot. Follow earthing instrucƟ ons carefully.

The most eff ecƟ ve place for an earth system is in conƟ nuously damp soil (illustraƟ on a).

Gallagher M150 — HOW TO INSTALL AN EARTH Έ GROUND Ή SYSTEM diagram (page 10)
Fig. 10

All live wire system (for areas with good earthing systems)

The animal must touch the wire and the ground to feel a shock

For dry areas with poor earthing condiƟ ons, install the fence using illustraƟ on b.

Gallagher M150 — All live wire system (for areas with good earthing systems) diagram (page 10)
Fig. 11 · All live wire system (for areas with good earthing s…

An earth wire return system (for areas with poor earthing)

The animal must touch both a live wire and the earth wire to feel an eff ecƟ ve shock

Earth stakes, at least 2m (6Ō ) long, should be spaced 3m (10Ō ) apart. Use a minimum of 3 earth stakes for the M150, M300, M500.

Gallagher M150 — An earth wire return system (for areas with poor earthing) diagram (page 10)
Fig. 12 · An earth wire return system (for areas with poor ear…

Use Cut-out Switches (G6076) to allow secƟ ons of the fence system to be switched off during fence maintenance. Put a switch at each gateway and at every major change in fence direcƟ on.

Page 11 of the Gallagher M150 user manual — HOW TO INSTALL AN EARTH Έ GROUND Ή SYSTEM
Page 11 · click to enlarge
Page 11
Gallagher M150 — HOW TO INSTALL AN EARTH Έ GROUND Ή SYSTEM diagram (page 11)
Fig. 13

These fi gures are guidelines only for fl at country condiƟ ons.

Post spacing 20 - 25 m (60 - 75 ft)

Post spacing 20 - 25 m (60 - 75 ft)

Post spacing 20 - 30 m (60 - 90 ft)

Post spacing 20 - 30 m (60 - 90 ft)

Post spacing 8 - 10 m (25 - 30 ft) Post spacing 15 - 30m (45 - 90 ft)

Post spacing 6 m (20 ft) Post spacing 15 m (45 ft)

150mm (6”) 150mm (6”) 150mm (6”) 150mm (6”) 150mm (6”)

For wire and post spacings in dry areas with poor earthing condiƟ ons, see your Gallagher dealer.

When joining wires under tension, use a fi gure eight or reef knot.

Gallagher M150 — HOW TO INSTALL AN EARTH Έ GROUND Ή SYSTEM diagram (page 11)
Fig. 14

Do not use copper wire anywhere in your fence system.

Page 12 of the Gallagher M150 user manual — Materials and Tools
Page 12 · click to enlarge
Page 12
EnglishENERGIZER AND FENCE MAINTENANCE CHART Fault Possible cause(s) SoluƟ on Energizer doesn’t operateEnergizer OffSwitch ON Break in supply circuitTest power point Faulty energizerHave energizer repaired Electric fence voltage is below 3000V or your stock are escapingFaulty energizerUnplug the energizer from the power supply and remove the fence wire from the Red terminal. Plug energizer in again. Using a Digital Volt Meter (G5030) check the voltage across the terminals. If the voltage is less than 5000V, have energizer repaired. Inadequate earthingImprove the earth system by adding more galvanised earth stakes to the earth system unƟ l the earth voltage is 200V or below. Short on the fence lineCheck the electrical connecƟ ons are secure eg. from the fence to the red terminal, from the earth system to the green terminal, at gates etc. Check the voltage on the fence every 33m (100Ō ) using the Digital Volt Meter. Note if the voltage is dropping. The closer to a fault, the lower the voltage reading will be. Become aware of things that cause faults and always be on the lookout for: stray pieces of wire on the fence, heavy vegetaƟ on growth, cracked or broken insulators, broken wires.

Materials and Tools

Gallagher dealers off er a complete range of products for your Power Fence. For fence specifi caƟ ons and design contact your Gallagher dealer.

On permanent Power Fencing, use high tensile, 12.5 gauge wire. Do not use barbed wire or 16 or 18 gauge wire. On portable fences, Polywire, Polytape or light gauge wire may be used.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Gallagher M150

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Gallagher M150

Be the first to ask — other owners or our team will answer.

Original document

Gallagher M150 manual PDF

74 pages·3.2 MB·Miscellaneous·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…