Page 4 of the Fysic FC-20 user manual — DESCRIPTION OF THE APPLIANCE:
Page 4 · click to enlarge
Page 4

DESCRIPTION OF THE APPLIANCE:

Thanks for your purchase! Physically, it is a commitment to make your environment more pleasant and easier. This personal humidifier from Physical improves air quality in your immediate environment by adding moisture to the air and thus ensuring a pleasant humidity level.

Proper humidity protects you from dry airways, prevents breathing problems and prevents dry and irritated skin. A sufficiently moistened environment prevents wood furniture from shrinking, causing cracks, and ensures that paper made of books or wallpaper is not dried out, fragile or distorted. Also, sufficient humidity ensures dust falls and remains less sticky to surfaces, which simplifies cleaning.

The humidity is usually indicated in percentage. This figure is the amount of water vapour in air compared to the quantity of water vapor that the air may contain at room temperature. In a

The ideal humidity is between 40% and 50%. A humidity of less than 30% is dry and can be considered uncomfortable. To measure the humidity in your environment, you can use a hygrometer.

The humidifier of Physic uses an ultrasonic high-frequency generator to break water into small particles. A fan blows these water particles into the air like a mist, where small particles are easily absorbed in the air. The ultrasonic technique ensures quiet operation without changing room temperature, covering the windows or condensing in the immediate vicinity.

Page 5 of the Fysic FC-20 user manual — FIRST USE:
Page 5 · click to enlarge
Page 5

FIRST USE:

1. Make sure the humidifier is switched off (the control button is all left, counterclockwise, turned) and the plug is disconnected from the power outlet. 2. Place the humidifier on a smooth surface at about 60 cm from the floor and 10 cm from your wall. 3. Instructions for filling the water reservoir (see Figure 2). -- Remove the water reservoir by lifting it straight up. -- Unscrew the cap at the bottom of the reservoir by turning counterclockwise and fill the tank with demineralised or distilled water. For the first time use, it is advisable to rinse the water tank first.

-- Do NOT fill the reservoir with hot water; this can leak

cause. -- Do NOT fill the reservoir with tap water. Crane water contains lime,

This lime can come with the water vapor and descend on your furniture or floor. The white layer that is left behind is difficult to clean. -- Put the cap back on the reservoir after filling it by turning clockwise firmly and place the water tank again on the base. The reservoir will immediately begin to drain into the base. 4. Connect the power cord to an outlet.

Page 6 of the Fysic FC-20 user manual — DAILY MAINTENANCE:
Page 6 · click to enlarge
Page 6

SPECIFICATIONS:

  • Product: Ultrasonic humidifier with cool vapour
  • Initiating voltage: 240V, 50Hz
  • Wetness capacity: ... 350 ml/ h
  • Water reservoir volume: 4.1 liters
  • Rated power: 30Watt
  • Dimensions: 280x167x165 mm
  • Weight: 1.4 kg
  • Coverage area: 90-110m 3

CLEANING AND MAINTENANCE:

Humidifiers provide the humidity required to protect our health. Follow all maintenance instructions carefully to enjoy the humidifier optimally and prevent any malfunction in the device. If recommended care and maintenance are not followed, micro-organisms may develop in the humidifier water. You can also develop a sensitivity to organic dust from the humidifier if it is not cleaned regularly. If breathing problems occur, stop using the humidifier immediately and consult a doctor.

DAILY MAINTENANCE:

1. Turn off the power and remove the device's plug from the socket before you start cleaning. 2. Lift the reservoir of the air-boiler from the base. 3. Bring the water reservoir to a sink, drain it, rinse thoroughly and remove any sediments or dirt. Wipe the water reservoir clean and dry with a clean soft cloth or kitchen paper. 4. Fill the water reservoir with fresh demineralised or distilled water, put the cap back on the reservoir and place it back on its base.

Page 7 of the Fysic FC-20 user manual — STORE THE HUMIDIFIER:
Page 7 · click to enlarge
Page 7

WEEKLY MAINTENANCE:

1. Repeat steps 1-3 for daily maintenance. 2. Pour away the water left in the base. Please note that you have not connected the device to the power when moving it. 3. Pour a cup of white vinegar (about 200 ml) into the reduction in base, where the transducer is located, and let it work for 15 minutes, then wipe off the attack in the base and especially in the transductor using the soft brush that is in the basic. 4. Remove the adhesive and white vinegar solution with a clean, soft cloth. 5. Rinse the base with water to make sure that no vinegar remains in the base, make sure not to immerse the basis in water, but just rinse the reduction into the base. 6. Fill the water reservoir with fresh demineralised or distilled water, put the cap back on the reservoir and place it back on its base.

PLEASE NOTE IN THE CASE OF MAINTENANCE:

  • Make sure the base is never immersed in water.
  • Do not use solvents or aggressive cleaning agents to clean the device.
  • Clean the inside with a soft cloth
  • Use only the brush to clean the transducer. This has to be done once a week.
  • Use only a brush with soft hair.
  • Refresh the water in the reservoir at least once a week if it remains in for more than one week.

STORE THE HUMIDIFIER:

  • Clean the humidifier as described above and dry thoroughly.
  • Preferably store the humidifier in its original box.
  • Avoid high temperatures.
Page 8 of the Fysic FC-20 user manual — WEEKLY MAINTENANCE:
Page 8 · click to enlarge
Page 8
Diagram . .
Diagram . .

If your humidifier is not working correctly, please check the following causes:

PROBLEMPROBABLE CAUSESOLUTION Air humidifier is not working.Power cord's not connected.Connect the power cord. The on/off light is red, no vapour appears.No water in the reservoir.Fill the reservoir with water. The water vapor spreads an unpleasant smell.New plane.Open the reservoir and place it for 12 hours in a shady, cool spot. Dirty water or the water has been in the reservoir for too long.Clean the water reservoir and change the water. The volume of the vapour output is low.The transducer is dirty.Clean the transducer with vinegar and a soft brush. Too dirty water or the water has been in the reservoir for too long.Clean the water reservoir and change the water. Unusual noise.Weather in the water reservoir when there is too little water.Fill the water reservoir with water. The device is located on an unstable surface.Move the device to a stable, flat surface. Dop very closely.Too hard on.Put some liquid soap in the cap to be able to easily open it. White hit on furniture and ground.Large amount of lime in the water used.Use demineralised or distilled water.
Page 9 of the Fysic FC-20 user manual — WEEKLY MAINTENANCE:
Page 9 · click to enlarge
Page 9

When handling electrical appliances, you should always take a number of safety measures to avoid the risk of fire, electric shocks and injuries. Please take into account, inter alia:

1. Check the voltage of the mains current to ensure that it corresponds to the nominal voltage for the device before you use it. 2. Never use the humidifier unattended in a closed room, especially when a child is asleep, resting or playing. 3. Do not add water directly via the moisture output. The device could be damaged. 4. Do not let children play with the product packaging, e.g. Plastic bags. 5. Never place the cord under carpets or near heating grids, radiators, heaters or heaters. 6. Do not place the humidifier near heaters, radiators and other heating devices. The humidifier must be 10 cm or more from a wall to obtain the best results. 7. Never use a device with a damaged cord or plug after the appliance has been defective or has fallen or damaged in any way. Return the device to the manufacturer for examination, adjustment or repair. 8. Always place the humidifier on a firm, flat, horizontal surface. 9. Do not turn the moisture drain directly to a wall. 10. Never tilt, move or empty the device while it is in operation. 11. Turn off the device and remove the plug from the socket before removing the water reservoir or moving it. 12. Do not try to repair or modify electrical or mechanical functions on this device. If you do, the warranty will be invalid. 13. The inside of the device does not contain any components that the user can maintain. Maintenance must only be carried out by qualified personnel. Opening the base station will be guaranteed by this product 14. Never use detergents, petrol, glass cleaner, furniture cleaning agent, paint thinner or other household solvents to clean part of the humidifier. 15. Too high humidity in a room can lead to water condensation on windows and certain furniture. If this happens, shut down the humidifier. 16. Never place the housing under running water or immerse it in a liquid.

Page 10 of the Fysic FC-20 user manual — CONSUMER SAFETY:
Page 10 · click to enlarge
Page 10

CONSUMER SAFETY:

Turn off the humidifier if moisture forms on the walls or windows of the room. The room is already more than moist enough and additional moisture can cause damage. Long-term excessive humidity can have negative effects, such as the growth of house mites and mold and makes the environment more fine for different insects. Also, was less good indoor drying.

When moisture appears on windows, this also indicates insufficient ventilation in the house.

An ideal humidity is between 40% and 50%.

Never block the air supply or drain.

The length of the cord used in this device has been chosen to reduce the risk of possible suffocation or trip over a longer cord. If you need a longer cord, you can use an extension cord. The electrical power of the extension cord shall be equal to or greater than the capacity of the humidifier. Be careful when placing the extension cord, so that it does not appear from or over a countertop or table where children can pull on it or stumble upon it accidentally.

Page 11 of the Fysic FC-20 user manual — CONSUMER SAFETY:
Page 11 · click to enlarge
Page 11
Diagram . .
Diagram . .
Page 12 of the Fysic FC-20 user manual — CONSUMER SAFETY:
Page 12 · click to enlarge
Page 12
Diagram . .
Diagram . .

Ask about the Fysic FC-20

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Fysic FC-20

Be the first to ask — other owners or our team will answer.

Original document

Fysic FC-20 manual PDF

12 pages·1.4 MB·Humidifier-Dehumidifier·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…