INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Your new wall oven has been designed to fit a limited variety of cutout sizes to make the job of installing easier. The first step of your installation should be to measure your current cutout dimensions and compare them to the cutout dimensions chart below for your model. You may find little or no cabinet work being necessary.
Do not remove spacers (if equipped) on the side walls of the built-in oven. These spacers center the oven in the space provided. The oven must be centered to prevent excess heat buildup that may result in heat damage or fire.
1½” (3.8 cm) Min.
H F
B
Door Open (see note 2)
opening under the appliance side rails. 5. For a cutout height (H) greater than 281/4" (71.8 cm) you can order a larger bottom trim through a Service Center.
Min.
2" (5 cm) Wide Wood Spacer if Needed
* Suggested distance from floor is 31" (78.7cm). Minimum required distance is 4 ½" (11.4cm).
Figure 1 27" and 30" Single Wall Ovens (Double ovens see Figure 2)
All dimensions are in inches (cm).
PN 807153701 Rev. C (15/05)
English – pages 1-8 Español – páginas 9-16
Printed in U.S.A.

Do not remove spacers (if equipped) on the side walls of the built-in oven. These spacers center the oven in the space provided. The oven must be centered to prevent excess heat buildup that may result in heat damage or fire.
1½” (3.8 cm) Min.
F
B
H
11½” (29.2 cm)
3” (7.6 cm) Max.
Door Open (see note 2)
2” (5.1 cm) Min.
Electrical Junction Box 2" (5 cm) Wide Wood Spacer if Needed
A
NOTES: 1. Base must be capable of supporting 300 pounds (136 kg) for 27" models and 375 pounds (170 kg) for 30" models. 2. Allow at least 21" (53.3 cm) clearance in front of oven for door depth when it is open. 3. Dimension G (cutout depth) is critical to the proper installation of the built-in oven. If the oven decorative trim does not butt against the cabinet, or if noise is heard on convection models, verify dimension G to assure it is according to the required dimension.
Figure 2 27" AND 30" DOUBLE OVENS (Single Ovens see Figure 1)
All dimensions are in inches (cm).
Hole for Cable · Spacer

Important Notes to the Installer 1. Read all instructions contained in these installation instructions before installing the wall oven. 2. Remove all packing material from the oven compartments before connecting the electrical supply to the wall oven. 3. Observe all governing codes and ordinances. 4. Be sure to leave these instructions with the consumer. 5. Oven door may be removed to facilitate installation. 6. THESE OVENS ARE NOT APPROVED FOR STACKABLE OR SIDE-BY-SIDE INSTALLATION.
Observe all governing codes and local ordinances 1. A 3-wire or 4-wire single phase 120/240 or 120/208 Volt, 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line (red and black wires). A time-delay fuse or circuit breaker is recommended. DO NOT fuse neutral (white wire). Only certain cooktop models may be installed over certain built-in electric oven models. Approved cooktops and built-in ovens are listed by the MFG ID number (see the insert sheet included in the literature package).
Stepping, leaning or sitting on the door of this wall oven can result in serious injuries and can also cause damage to the wall oven.
The electrical power to the oven must be shut off while line connections are being made. Failure to do so could result in serious injury or death.
An extension cord should not be used with this appliance. Such use may result in a fire, electrical shock, or other personal injury. If you need a longer power cord you can purchase a 10' (3 m) power cord kit #903056-9010 by calling the Service Center.
2. These appliances should be connected to the fused disconnect (or circuit breaker) box through flexible armored or nonmetallic sheathed cable. The flexible armored cable extending from the appliance should be connected directly to the junction box. The junction box should be located as shown in Figure 1 or Figure 2 and with as much slack as possible remaining in the cable between the box and the appliance, so it can be moved if servicing is ever necessary. 3. A suitable strain relief must be provided to attach the flexible armored cable to the junction box.
Table A

(If your appliance is equipped with a white neutral conductor.) This appliance is manufactured with a white neutral power supply and a frame connected copper wire. The frame is grounded by connection of grounding lead to neutral lead at the termination of the conduit, if used in USA, in a new branch circuit installation (1996 NEC), mobile home, recreational vehicles, where local code do not permit grounding trough the neutral (white) wire or in Canada, disconnect the white and green lead from each other and use ground lead to ground unit in accordance with local codes, connect neutral lead to branch circuit-neutral conductor in usual manner see Figure 4. If your appliance is to be connected to a 3 wire grounded junction box (US only), where local code permit connecting the appliance-grounding conductor to the neutral (white) see Figure 3.
Failure to do any of the above could result in a fire, personal injury or electrical shock.
NOTE TO ELECTRICIAN: The armored cable leads supplied with the appliance are UL-recognized for connection to larger gauge household wiring. The insulation of the leads is rated at temperatures much higher than temperature rating of household wiring. The current carrying capacity of the conductor is governed by the temperature rating of the insulation around the wire, rather than the wire gauge alone.
In cold weather shipping and storage conditions, make sure that oven is in final location at least three (3) hours before switching on power. Switching on power while oven is still cold may damage the oven controls.
Where local codes permit connecting the appliance- grounding conductor to the neutral (white) wire (US Only) (see figure 3): 1. Disconnect the power supply. 2. In the junction box: connect appliance and power supply cable wires as shown in Figure 3.
Risk of electrical shock (Failure to heed this warning may result in electrocution or other serious injury.) This appliance is equipped with copper lead wire. If connection is made to aluminum house wiring, use only connectors that are approved for joining copper and aluminum wire in accordance with the National Electrical Code and local code and ordinances. When installing connectors having screws which bear directly on the steel and/or aluminum flexible conduit, do no tighten screws sufficiently to damage the flexible conduit. Do not over bend or excessively distort flexible conduit to avoid separation of convolutions en exposure of internal wires.
Cable from Power Supply
White Wire (Neutral) U.L.-Listed Conduit Connector (or CSA listed)
DO NOT ground to a gas supply pipe. DO NOT connect to electrical power supply until appliance is permanently grounded. Connect the ground wire before turning on the power.
Ground Wire (Bare or Green Wire)
Figure 3 3-WIRE GROUNDED JUNCTION BOX

If oven is used in a new branch circuit installation (1996 NEC), mobile home, recreational vehicle, or where local codes DO NOT permit grounding through the neutral (white) wire, the appliance frame MUST NOT be connected to the neutral wire of the 4-wire electrical system. (see figure 4): 1. Disconnect the power supply. 2. Separate the green (or bare copper) and white appliance cable wires. 3. In the junction box: connect appliance and power supply cable wires as shown in Figure 4.

Do not lift or manipulate the oven by the door handle or the control panel.
Cable from Power Supply
1 Unpack the wall oven. Remove the bottom trim
taped on the oven top panel. 2 Find the 2 anti-tip mounting screws included in the
literature package. 3 Insert the oven into the cabinet opening. Slide
oven inward leaving 1½" (3.8 cm) clearance between the oven and front of cabinet (see Figure 5). 4 Pull the armored cable through the hole for it in the
Ground Wire (Bare or Green Wire)
White Wire Junction Box
cabinet and toward the junction box while moving the appliance inward. 5 Push the oven in and against the cabinet.
U.L.-Listed Conduit Connector (or CSA listed)
Figure 4 4-WIRE GROUNDED JUNCTION BOX
Model and Serial Number Location The serial plate is located along the interior side trim of the oven and visible when the door is opened.
When ordering parts for or making inquires about your oven, always be sure to include the model and serial numbers and a lot number or letter from the serial plate on your oven.



1½" (3.8 cm) clearance between unit


Single Wall Oven Serial Plate Location
Double Wall Oven Serial Plate Location


The wall oven can tip when the door is open. The anti-tip mounting screws supplied with the wall oven must be installed to prevent tipping of the wall oven and injury to persons.
Bottom trim must be installed for the oven to function properly. DO NOT operate the oven without bottom oven trim installed. Do not use wood or any other trim that is not manufactured for use with this model. Operating the appliance without manufacturer's bottom trim properly installed may cause personal injury and may damage cabinetry or the appliance.
A. The mounting holes in the side trims may be used as a template to locate the appliance mounting screw holes (see figure 6). B. Use the two screws supplied to fix the appliance to the cabinet.
Screws to attach the bottom trim are supplied with the oven. Screws are located in the mounting holes located on each side trim, below the oven frame (see Figure 7). A. Remove the screws from the mounting holes. B. Place the top of the bottom trim over the side trim tabs on each side of the oven below the oven door. C. Attach the trim using the provided screws.







Refer to the installation instructions supplied with your appliance for proper installa- tion.


Check for proper installation with a visual check that the anti-tip screws are present. Test the installation with light downward pressure on the open oven door. The oven should not tip forward.
Anti-Tip Mounting Holes · Anti-tip mounting holes

For typical under counter installation of an electric built-in oven see Figure below.
Only certain cooktop models may be installed over certain built-in electric oven models. Approved cooktops and built-in ovens are listed by the MFG ID number and product code (see the insert sheet included in the literature package and cooktop installation instructions for dimensions).
Cabinet side filler panels are necessary to isolate the unit from adjoining cabinets. Cabinet side filler height should allow for installation of approved cooktop models
Approx. 3”
To reduce the risk of personal injury and tip ping of the wall oven, the wall oven must be secured to the cabi net (s) by mounting screws.
36” Min. (91.4 cm) Min.
H
208/240 Volt junction box for built-in oven.
Use 3/4” (1.9 cm) plywood, installed on two runners, flush with toe plate. Base must be capable of supporting 150 pounds (68 kg) for 27" models and 200 pounds (90 kg) for 30" models.
Cut an opening in wood base minimum 9” x 9” (23 X 23 cm), 2” (5 cm) from left side filler panel, to route armored cable to junction box.
4 1/2” (11.5 cm) Max.*
* If no cooktop is installed directly over the oven unit, 5” (12.7 cm) maximum is allowed above the floor.
Figure 8- TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT-IN


Figure 9 - TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT-IN OVEN
6. Leveling the Wall Oven 1. Install an oven rack in the center of the upper oven (see Figure 10). 2. Place a level on the rack. Take 2 readings with the level placed diagonally in one direction and then the other. Use wood shims under the wall oven to level if necessary. 3. Repeat in the lower oven if you have a double cavity wall oven. If the level indicates that the rack is not level, use wood shims to reach a compromise for both ovens.

Broil– When the oven is set to BROIL, the upper element in the oven should become red.
Convection (some models)–When the oven is set for a convection baking or roasting, both elements cycle on and off alternately and the convection fan will run. The convection fan will stop running when the oven door is opened.

Before You Call for Service Read the "Before You Call for Service Checklist" and the "Operating Instructions" in your Use and Care Guide. It may save you time and expense. The list includes common occurrences that are not the result of defective workmanship or materials in this appliance.
Refer to your Use and Care Guide for service phone numbers.