Wireless alarm system for 6 zones
With integrated telephone dialing device


All components of this wireless alarm system are manufactured to provide a high level of security, durable and reliable.
No radio licence is required for these devices. Radio reception characteristics could be affected by other signals. Further information can be found in the chapter Radio interference protection.
The radio-controlled devices in this system have been tested by an independent approved laboratory for R&TTE compliance of radio-guided devices.
The system is designed to be easy and installed with conventional tools. Nevertheless, it is important that the installer reads the manual before installation so he understands the procedure.
During installation, it is important to follow the detailed procedure from the manual.
This manual should be kept safe for future needs.
All components (except for radio external sirens) are only suitable for installation in a dry interior.
You need the following tools and materials:
5 and 6mm dowels
The system should be based on local or national regulations and laws are installed and operated. We recommend that you refer to the location or apply nationally applicable rules to the competent authority. We would like to point out that the devices of this series are not VDS tested! No liability or reimbursement of costs for damages incurred can be assumed!
This system is designed to detect burglars when installed correctly, but also has a strong deterrent effect on possible burglaries.
Please note, however, that with appropriate expertise and time each alarm system must be overcome and we therefore recommend the use of an alarm system always in conjunction with good physical protection such as e.g. Safety fittings for windows and doors.
All devices in the system are matched with an 8-bit house code and configured by the user/installer to use a unique identification code for installation. The system house code can be changed by the user at any time.
The system may be controlled by one or more remote controls or the central processing unit.
You should make sure that you do not lose your remote control and the user code for the central unit is not made known to other people, as this can affect the security of the system. In both cases, the system house code and user code should be changed as soon as possible.
Please always follow the manufacturer’s instructions when using tools, ladders etc. use and wear protective equipment (e.g. goggles) when you drill holes. Before drilling holes into the wall, please check if hidden cables and water pipelines could be hit.
If you use a ladder, please ensure that it is placed on stable ground at the correct angle and secure.
The use of earmuffs is advisable if you work near the siren, as it emits high and loud tones.
Screwdriver · Drills · Ahle / Pfriem

The menu on the LCD display is in English. The words are translated into German in this manual and stand in brackets behind the English word. But: Don’t worry, many words (ON, OFF, Replay, User...) you already know from other devices (such as e.g. Your video recorder.
For a better overview, the following terms are listed and translated alphabetically here:


INTRODUCTION AND OVERVIEW 9-11
Multiple user installation sharply switch input/output delay zones lock-off zone Quick setting Last output zone setting Transit Zone Injunction Zone Event Protocol Gong telephone dialer latch key (Digital house key function) Answering machine Message recording Telephone remote control of on the go sabotage protection Radio early detection battery status indicator system home code
RADIO HANDHELD TRANSMITTER 13
Basic information setting of the radio handheld transmitter
Positioning of the radio control center Installation of the wireless control center 15 Setting of the Radio control center 16 Testing of said radio control station and of said handheld transmitter 16
Positioning of the PIR radio motion detector Installation of the pir radio motion sensor Setting of the PIr radio motion indicator Testing of PIR wireless motion detector
Positioning of the Radio Magnetic Contacts Installation and adjustment of the radio Magnetic contacts Testing of radio Magnetical Contacts
TESTING THE SYSTEM 25
Initial test testing of the installed system
Changes to factory settings
User setting 29 System setting 30

Zone setting 35 Set telephone dialing device 38 Set full-sharp 40 Part-Sharp 1 Set 42 Part-shirl 2 Set 43 Time and date 44 Set Latch Key - Setting 45 answering machine – Set 46 Phone remote control on the go - Set 47

Basic system sharp switching System partially sharp switch (part arm 1) System part sharp switch system unsharp Switch Quick setting cease-and-desist zone panic function sabotage protection Gong event protocol message recording remote control by phone from the road battery status indicator
RECORDING ALARM MESSAGE 56
PROBLEM MANAGEMENT 57
EXTENSION OF THE ALARM SYSTEM 60
SPECIFICATION OF THE DEVICES 62

The following components are attached to the scope of delivery of the alarm system:
1 x PIR radio motion detector
In addition,
Power adapter for the socket
Manual of installation and operation
Batteries, screws and dowels



With the following accessories you can expand your system and thus gain a higher degree of safety.
Art. designation Content
SU1F Two radio magnetic contacts and a handheld transmitter
More details about accessories can be found on page 60.

The system can be configured for up to 6 users as well as a main user.
This allows the event log to record which users have switched the system sharp and fuzzy. Each user receives a different access code. Additionally, a 4-second voice recording can be used to record the user’s name in order to use the latch key.
Only the main user has access to programming functions and is able to configure the system.
The system can be switched completely (Full ARM), i.e. for all zones sharp but also only partial sharpness (part arm).
Example:
The system could be configured to switch the system partly sharp during night, ensuring that only the ground floor and garage are set but you can move freely on the upper floor without triggering an alarm.
However, if the house is unoccupied, full focusing can ensure monitoring of all areas in the ground floor and upper floor.
Each zone can be programmed to monitor either immediately or in delay mode.
Usually, the zones that monitor the entrance door and the routes to and from the radio control center are set to delay mode. This ensures that the user has sufficient time to leave the building after setting up control center or to fuzzily switch the system when he re-enters the building so as not to trigger an unwanted alarm.
The remaining zones are usually configured to trigger alarm directly and without delay.
Delayed alarm zones are only switched fully energized after the delay time for access/output has elapsed. Thus, if an alarm is triggered in a zone with delay, no alarm will be triggered until the time for access/output has elapsed.
If the system is not switched to be unsettled during the delay time, an alarm shall be triggered when the delay period has elapsed.
Zones without delay mode trigger alarm immediately when the system is switched to live.
The system is designed for 6 wireless surveillance zones that independently of one another can accommodate different areas of a building or the like. You can monitor an apartment.
In addition to the actual protection against burglary, the following functions can be used:
- The Panic button can trigger an alarm for 24 hours in the event of immediate threat.
- 24-hour monitoring for special areas (e.g. Weapon cabinet
- 24-hour monitoring of smoke/fire development by integrating smoke detectors into the plant.
In addition, four hard-wired zones can be connected to the radio center that are configurable with the same characteristics as wireless zones (1 - 6).
If an alarm of an active zone is triggered while the system is switched to a state of readiness, then an alarm will be triggered. After the programmed alarm duration has elapsed, the alarm stops and the system is automatically returned to its initial state. Subsequently triggered detectors will again trigger an alarm. If a single zone triggers an alarm more than three times, this zone is “locked” and radio signals from this zone are ignored until the system is switched out of focus.
With a quick setting, the system can be switched fully energized within 5 seconds if the programmed output delay is passed over. This can be useful if the output delay signal, which sounds in the form of a beepton, should end at night after only a few seconds.

Triggering a detector of a last output zone during the initial delay extends the initial deceleration by another 5 seconds.
This function could be used to briefly shut down the detectors of a zone that monitor the route between the main entrance door and the radio control center.
If the system is switched to a state of play and buildings/apartment are entered through the entrance zone, then the input delay works normally. All input zones are switched off to provide free access to the radio control center, in order to fuzzily turn the system before the input delay time of the input zone elapses and alarm is triggered.
The zone which is set as an input zone must be set with sufficient input delay time in order to reach the radio control center and switch the system out of focus.
This function allows a zone to be omitted while the system is switched sharply. If the system is switched out of focus again, all recess zones are erased.
The radio control center is able to log the last 50 events of the system. This allows the user to see which user has switched the system sharp/unsharp and if and when an alarm was triggered. Time, date and details are recorded for each event.
The gong is a simple function for using the system in standby mode. If the gong setting is ON and a detector or zone reports a radio signal to the control center, a gong sounds. A typical application is this function when a door or a certain area should be monitored, but no loud siren should be triggered.
A telephone dialing device is integrated into the control center, which serves to switch on the alarm message up to four numbers in case of a break-in (mobile phone, relatives, guard service etc.).
In the event of a break-in, the telephone dialing device (when enabled) will call the first input phone number in the sequence and report the received message for the set playback time. The recipient shall:
must confirm the message by placing the button
Press on the phone. If the call is not received or acknowledged, the next activated telephone number of the entered sequence will be called automatically. The telephone dialing device will dial each registered number until all the numbers have been dialed or are called. a call was received and confirmed beforehand.
If the system is fuzzy and the latch key function on, when entering the building, the telephone dialing device will call the first latch key phone number and reproduce the user message (which was entered for the user), namely for the set playback time. The recipient must confirm the message,
by placing the key
Press on the phone. If the call is not accepted or an acknowledgement of receipt has not been made, the second latch key telephone number will be dialed. The telephone dialing device continues to dial each number alternately until each number has been called according to the set call number or the sequence has been stopped/confirmed by the receiver.
For example, the latch key can be used to inform parents on-the-go when children have come from school and fuzzed their system.
The function of an answering machine is integrated in the radio control center. The answering machine records and stores a maximum of 6 messages with a limited call time of 30 seconds each.
Messages can be retrieved either directly from the radio control center or by a call to the system.
In addition, it is also possible to speak messages on the radio control center which can be tapped by others in order e.g. Save “subscription notes.” Any message can be max. It takes 30 seconds and counts as if

An incoming call message.
It is possible to query the status of the system from on the go with the help of the telephone, but also basic settings (e.g. the setting/unsetting circuit. In addition, you can activate the microphone on the go to listen into the monitored rooms.
Also answering machine and message memory can be accessed from the road.
All devices (except the radio handheld transmitter) have sabotage protection to avoid unauthorized persons having unauthorised access to the devices in order to influence them. Any attempt to remove the battery cover from a device (except for handheld radio transmitters) or take off the control panel from the wall will trigger an immediate alarm (unless the system is in test or programming mode). This also occurs when the system is switched in a fuzzy manner. The optional radio external siren also has such sabotage protection, so that it cannot be torn down from the wall without alarming.
In order to alert the system against illegal radio interference signals, a special early detection has been integrated into the Radio Center.
If this function is set and the radio frequency continuously disturbed for 30 seconds (if the system is switched to a state of readiness), the Radio Center will emit an alarm in the form of beeps (permanently for 5 seconds). If the radio interference continues for another 10 or more seconds, a full alarm is triggered. This also happens if the system has been disturbed more than three times for 10 seconds over a period of 5 minutes.
Radio early detection is designed in such a way that it detects permanent interference signals. It cannot be ruled out that there may be local radio interference from systems operating legally or illegally on the same frequency. If you do not want to use radio early detection, we recommend that you observe the system at least two weeks in advance for possible radio interference (the radio early recognition must be switched on).
In addition to the battery monitoring and low-battery status display, the radio control center also indicates in the event log if wireless motion detectors or magnetic contacts have a low battery status.
To prevent unauthorized users from influencing or If you are not focused, you must set your system to respond exclusively to radio signals from your own devices. This is ensured by setting the eight miniature DIP switches in all devices (except for central control), just like the ON/OFF combination of house code set by user/installer.
The radio control center is then programmed to respond exclusively to devices with house coding. All detectors and radio handheld transmitter/control panels must be set to the same house code in order for the system to function correctly.
In the radio motion detector, the radio magnetic contact as well as the radio handheld transmitter and the radio control panel are installed fields with 8 DIP switches each which must be set according to the house code.

The house code is set by setting the 8 DIP switches of each device according to the ON/OFF combination of the house code. When setting the switches, please make sure that each switch latches into the desired position. For this purpose, you can use the tip of a pin or screwdriver.

The following example shows a typical building with the recommended positioning of radio control center, radio motion detector and radio magnetic contact. This should serve you, together with the recommendations in the user manual, as orientation during installation.

Before installing the alarm system, it is important to read the safety instructions and plan installation carefully.
The alarm system can be extended to ensure greater protection by e.g. additional PIR radio motion detectors, radio magnetic contacts or also radio control fields can be used. In addition, a solar-powered radio exterior siren is available.

The radio hand transmitter serves to switch the system sharp/partially-set and out of focus.

The radio handheld transmitter also has a panic button for direct threat. Pressing (sliding up) the panic button immediately triggers a full alarm, regardless of whether the system is switched sharp or out-of-focus. The alarm can be stopped by actuating the unset button or via the control center.
Any number of radio handheld transmitters can be used for system control as long as they are all set to the same house code.
The radio handheld transmitter is supplied with a CR2032 lithium button battery, which under normal circumstances lasts just over one year. Usually, the LED light on the hand transmitter only glows when a button has been pressed. If the battery status is low, however, this will be signaled by it continuing to light permanently after the button has been released again. In this case, the battery should be replaced as soon as possible.



To find the appropriate position for the central station, the following points should be considered:
Exterior view of the radio control center


Blue cable to –ve Battery connector
Black cable to –ve Battery connector
Interior view of the radio control center

on the radio control center, in order to bring the system back into its basic position.
With the control center in standby mode (only the power LED lights up).
. Main user access code
‘1. ‘USER SETUP’ (User TERMINATION) appears in the display.
This puts the system into programming mode.
Until I get to the menu '2. ‘SYSTEM SETUP’ appears and
The current house code appears in the display.
At the radio control centre:
Pressing buttons 1-8 of the control center allows you to set the house code. By pressing the keys 1 - 8, either "O" or "1" is established as a coding. In this way, you configure the eight-digit house code from a number combination 0 or 1, e.g. 01010101.
1 = House code DIP switch is on ON/UP
0 = House code DIP switch is OFF/DOWN
Hand transmitter, press the button
on the radio handheld transmitter.
When the control center receives the signal from the radio hand transmitter, a beep sounds and the display will show the changed house code below numbers 1-8.
to save the new setting or
to leave the area without storage.
to return to standby mode.
‘TEST MODE – WALK TEST’ (TEST-MODUS – RUN-TEST) appears on the display.
This puts the system into test mode.
Until the ‘WALK TEST’ menu appears.
To activate the test.
‘Walk Test Waiting...’ appears on the display.

LED lights up and a double beep sounds in the central station.
PIR motion detectors are developed to detect movement in a monitored area by registering heat changes from infrared radiation planes, e.g. when a person runs into the detection area or moves in it. If movement is detected, a radio signal will be triggered (if the system and zone are switched to live).
Any number of PIR radio motion detectors can be used for the system as long as the house coding is consistent and the detector is within a range from the radio control center.
The PIR radio motion detector is powered by a 9V block battery, which under normal circumstances has a life of just over 1 year. If the battery becomes too weak, an LED display behind the lens is illuminated in normal mode and with the housing closed. If this state occurs, the battery should be renewed as quickly as possible.
The recommended position for a PIR radio motion detector is in the corner of a room at an altitude between 2 and 2.5m. At this height, the detector reaches a maximum range of up to 12m with a monitoring angle of 110°.

The position of the PCB inside the PIR can be set in 5 different positions to establish the desired monitoring range. Position 3, the range is reduced to approx. 9m, with position 1 you reach a range of approx. 6 m. Position 5 is recommended.
When planning and deciding the assembly position, for a problem-free function, the following should be taken into account:

Make sure the system is in test mode.

Zone 1 OFF OFF
Zone 2 OFF OFF ON
Zone 3 OFF ON OFF
Zone 4 OFF ON
Zone 5 ON OFF OFF
Zone 6 ON OFF ON
e.g. If you want the PIR to work in Zone 3, set the DIP switches as follows:
ON Walk Test Mode (Run-Test mode)
OFF Normal Function

The 1-pulse monitoring is recommended. In the event of extreme environmental influences or unreasonable false alarms, 2-impulse monitoring may be necessary.
To set the desired pulse number, slide the DIP 5 switch on SW3 as follows:
To easily set the PCB position, simply slide up or down the “PCB Position Indicator” (see sketch) until it comes with the desired monitoring range (see table).

Make sure the system is in test mode.
Make sure the motion detector is set to “Walk Test Mode” (e.g., Run-Test mode). DIP 4 on the SW3 ON) and mounted to the wall.
The motion detector takes 2-3 minutes to stabilize before the test begins.
appears through the menu up to in the ‘WALK TEST’ (LAUF-TEST) menu.
, to activate the run test.
“Walk Test Waiting...” (LAUFT-TEST WAITING...) is displayed.
If necessary, adjust the monitoring range by changing the PCB position within the housing.

to return to the menu level TEST MODE (TEST-MODUS).
The magnetic radio contact consists of two parts: a detector/transmitter and a magnet. These have been specially developed for use on doors and windows. The magnet should be attached to the movable/opening part and the detector/transmitter to the fixed part (door/window frame). The fastening can be done using either the adhesive strips or screws (both are attached). Note: If the detector is mounted on a wallpaper, you should use screws.
When the door/window to be monitored is closed, the magnet and detector are positioned at a small distance from each other in the marked positions, i.e. the arrow of the magnet points at a small distance to the line of the detector/transmitter. By opening the window/door, magnet and detector/transmitter are removed from each other and thus a radio alarm signal is triggered if the alarm system and zone have been switched to sharp.
The radio magnetic contact also has a device for an additional wired contact. This additional contact must have a normal closing contact with open contacts in order to be able to trigger an alarm.
Any number of radio magnetic contacts can be used for the system as long as they are all configured with the appropriate house coding and within wireless range with the control center.
The radio magnetic contact is supplied with two CR2032 lithium button cell batteries, which under normal circumstances have a service life of approx. 1 year. In normal battery status, the detector LED will not light up when alarm is reported (except in test mode). At low battery status, the LED is set for approx. Light up for 1 second when the detector is triggered. In this case, the batteries should be renewed as soon as possible.
The radio magnetic contact is suitable only for mounting at dry points in the interior.
Decide which doors and windows should be secured by radio magnetic contacts (usually, at least the front and rear doors should thus be secure). In addition, however, additional radio magnetic contacts (e.g. in the garage) to increase protection.
Ensure that the selected position for radio magnetic contact is in effective radio range to the control center (see “Test Radio Control Center and Hand Transmitter”).
Make sure the system is in “Test Mode” (test mode).


If you want to screw, use the screw guide on top of the detector and pierce the screw marking at the bottom, underneath the battery holder (visible from inside). Please make sure that you do not overtighten the screws, otherwise the housing could be damaged.

If you are using an additional wired magnetic contact with the radio detector, the jumper LInk S2 on the PCB must be removed.


Zone 1 OFF OFF
Zone 2 OFF OFF ON
Zone 3 OFF ON OFF
Zone 4 OFF ON
Zone 5 ON OFF OFF
Zone 6 ON OFF ON
Example: If the detector is to operate in zone 2, the DIP switches 9, 10, 11 must be set as follows:

Make sure the system is in test mode “TEST MODE”.
Until the “WALK TEST” menu appears.
to activate the Walk Test.
‘Walk Test Waiting...’ appears on the display.
The LED is set for approx. Light up for 1 second when the battery cover is removed and thus, the sabotage switch is activated. In addition, the radio control center will emit a two-tone beep to signal that an alarm has been received and "Accessory Tamper" (accessories sabotage) appears in the display.
As soon as the magnet moves away from the transmitter, the LED lights up for approx. 1 second to show that the detector

was triggered. In addition, the radio center will sound a two-tone beep to show that an alarm signal has been received and the zone for which the detector was configured is displayed on the screen.
to return to the test mode.

The radio control center also makes possible the connection of wired zones (7 - 10) e.g. smoke detectors, sirens etc. or external telephone dialing device. The terminal block is located inside the radio control center.

To access the terminal block, press
This puts the system into test mode and prevents alarm triggering. Turn the two top screws out on the center and open up the front cover.
Before connecting any devices, make sure the memory jumper link P1 is on “OFF” and then remove the power plug and disconnect the support batteries/buffers.
After you connect the external devices, they restore power supply. Close the control panel again and turn back on the screws of the cover.
to leave the test mode and go back to standby mode.
, · , · User access code

When the system is installed, it is recommended that each device be tested alternately according to their respective test instructions.
The radio control center has a programmed test routine. You can of course test the system at any time, but it is generally recommended that you test it in intervals not longer than 3 months.
With the system in standby mode
This puts the system into test mode.
The system is now in test mode
Press the buttons
to select the appropriate test function or get into sub-menus.
to control through the menu and press
to leave the test mode and enter standby mode.

Before you start the test, please make sure that there is no movement of an area monitored by a radio motion detector and no door/window opening and that battery and case covers are correctly closed.
‘Walk Test Waiting...’ appears on the display.
(e.g., ‘REMOTE CONTROL DISARM’ = handheld radio transmitter fuzzy.
, · , · User access code

to leave the Walk Test mode (Run-Test Mode) and go into test mode.
in test mode until “ALARM TEST” appears on the display and press
to trigger the selected alarm for 5 seconds.
until the desired alarm appears in the display and press
Select “Wirefree Siren Test” to activate the external solar radio siren
(if fitted).
Select ‘Hardwired Siren Test’ to be integrated into the control centre as well as
activate an external wired siren (if wired).
Select ‘Relay Test’ to activate only the external wired siren (N.O./N.C.).
to leave the “Alarm Test” mode and go to test mode.
A service mode function is built into the siren, which prevents the sabotage switch of the sirin from triggering an alarm when the siREN is removed from the wall to perform maintenance or battery replacement. After the batteries have been changed and the siren has been brought back into position, it must be returned to normal mode or else it will not react in case of an alarm.
in test mode until ‘Wirefree Siren Service ON/OFF’ (Radio-Sirene Service AN/OUS) is displayed.
, to put the radio siren into operation or service mode. The mode in which the Sirene bureau is located shall be indicated as follows:
Service mode: The siren will emit two short beeps and LED flashes, then after approx. 6 seconds of a longer sound/LED flash, immediately followed by two beeps/LED blinks to signal that it is in service mode.
Operating mode: After approx. A long beep/LED flash sounds for 6 seconds to signal that the siren is in normal operation mode.
to leave Sirene Service mode and return to the Test menu level mode.
in Test mode until ‘VOICE DIALER TEST’ (TEST TELEFONSELECTION DEVICE) appears
The test call sequence can be set at the radio control center by pressing
They are stopped or even
call receivers by pressing
on the telephone control panel.
to leave the alarm test and return to menu level Test mode.
and press

House Code Not programmed Alarm Time: ON (AN), 180s Wirefree Siren (Radio-Sirene): ON(AN) RF Jamming Detection: OFF (OFF) Back Light: 10s Alarm Relay: On Until Disarm (AN to unsetting) Zone Lockout: ONE (AN) Remote Phone Control ON/AN Telephone remote control: OFB (Off) Dial delay: OT (Choose detention method): Tone/DTMF dialler mode (Selection mode): Voice Dialler Zone Setup (zone setting) (applies to all zones, except otherwise specified).
Name: No Name Type (Type): Break-in Final Exit: OFF Chime (Gong): OFF (OFF) Entry Delay: Zone 1: ON (AN), 30s Zone 2-10: OFS Part Arm 1 (Partial Sharp 1): OFB(OFF). Voice Dialler Setup (Telephone dialer setting)
Phone Numbers: Not Programmed Message Play Time (Message Announcement): 70s Alarm Messages: Unprogrammed Call Routing (Call Order): All numbers off Call Confirms (CALL Acknowledgement): 1 Call Attempt Full Arm Setup (Full Alert Setting)
Exit Delay: ON (AN), 30s Entry Delay Beep input delay beep: ONE (AN) Exit delay beef: ATE Part-Arm 1 Setup (Partially sharp 1 setting)

Exit Delay: ON (AN), 30s Entry Delay Beep: ONE (AN) Exit delay beep: Time & Date (Time & date)
Status: OFF (OUS) Selected User Setup:OFF (OFF, all users) Phone Numbers: Not programmed Answer Phone Setup (answering service setting)
(RESTORING FACTORY SETTINGS9)
to put the system into test mode. User access code
The radio control center will now independently restore all factory settings. The radio control center will now display ‘EEPROM RESET’ while the factory settings are stored. When the settings save is finished, ‘DISARM READY’ (UNSTARFLY) appears. The radio control center is now programmed with all factory settings.
, · ,

first menu level and the respective sub-menus. Throughout
You get into the respective function and with a
in the respective submenus. Then again, the previous ones. Getting to higher menu level
The system is in standby mode.
Master User Access Code (main user access code)
The system is now in programming mode
Use the buttons
, in order to provide the displayed programming function or Select the submenu.
to get through the programming menu. Press
to leave programming mode and return to standby.

Press the buttons
, to the first menu level on the menu item “1”. USER SETUP (1.)
User Adjustments) and then press
, to the USER 1-6 (user 1-6) as well as
MASTER-USER (main user) to program. They will find it by restoring the keys.
Press.
back to the higher menu level.
Workplace setting: not programmed.
Press the buttons
to show the desired user (user) in the display and
, to program the user access code. ‘1 Access Code’
appears in the display. Press on
and in the display appears "Enter Access Code". Now enter a 4-digit code that identifies the respective user (e.g. 4711) and confirm with
. If you want to change it, press them.
, then enter another code and

Record User Message (recording user message)
This allows each user to record a short (4 seconds) message, which can be used in the latch key function (door key), e.g. System of USER-1 fuzzed.
Until the menu ‘:2 Record User Message’ appears.
To record a new message, press
, to start the voice recording (max. Duration: 4s. After recording the voice, the device repeats the message
to leave the level without change.
Replay User Message (Replay of the user message)
until the menu ‘:3 Replay User Message’ appears.
to repeat the message.
, to get to the menu level user setup (user setting).
UP TO THE ‘1-7 MASTER USER SETUP’ MENU (1-7 MAIN USER SETTING)
Then it is displayed and presses.
‘1 Access Code’ (1 access code) and the current setting is displayed.
Enter a new 4-digit user code and then press
to save and leave the menu level, or
to leave the menu level without storage.
, to get to the higher level menu “User Setup” (user setting).
or


on the first menu level up to ‘2. SYSTEM SETUP’ (2. SYSTEM-
Settings) is displayed and then press
to return to the first menu level.
until the menu ‘2-1 Learn House Code’ (2-1 Learning System-House Code) appears.
The current house code is displayed. A new house code can be programmed either directly on the radio control center or with the help of the handheld radio transmitter.
At the radio control centre:
Press buttons 1-8 on the radio control center to program the desired house code. Each time buttons 1-8 are pressed, the setting is converted from “0” to “1”, or from “1” to ‘0’ so that an 8-digit house code results from a combination of “0“ and “1”.
1 = House Code DIP Switch On/Up
0 = House Code DIP Switch Off/Down
With the help of a handheld radio transmitter:
Set the DIP switches of the radio station to the desired house code and press
on the radio handheld transmitter.
When the radio control center receives the signal from the hand-held radio transmitter, then the central station emits a beep as an acknowledgement of receipt and the house code changes according to the setting of the DIP switches of the handheld radio receiver.
to save the new setting, or
, to leave the menu level without storage.
until the menu ‘2-2 ALARM TIME’ (2-2 alarm time) appears. The current setting is also displayed.
2-2-1 On/Off status
Then the key

until the menu ‘2-2-1 Status’ appears. The current setting also appears.
to activate the siren, or
to take the siren off.
2-2-2 Alarm Duration
until the menu ‘2-1-2 Time’ (2-1-2 time) appears.
Enter the desired alarm duration in 10s units, e.g. Enter 6 for an alarm duration of 60s (max.) Setting: 60, i.e. 600s/10min.
to save and leave the menu level, or
to leave the menu level without saving.
, to get to the first menu level.
until the menu ‘2-3 Wirefree Siren’ (2-3 radio siren) appears. The current setting is also displayed.
, to turn on the radio siren; or
to turn off the radio siren.
This function recognizes radio interference signals of the Radio Center at an early stage. If this function is activated, radio signals are continuously monitored on the operating frequency in order to avoid interference of the central station. If a disturbance signal is present, an alarm is triggered.
until the menu ‘2-4 RF Jamming Detection’ appears (‘2-4 Radio Interference Protection’). The current setting is also displayed.
to turn on jammaning detection (radio interference protection), or
, to turn off the function.
This controls the duration of backlighting on the radio center, which is active after pressing the last button.
until the menu ‘2-5 Back Light’ (2-5 lighting) appears. The current setting is also displayed.
until the desired duration is displayed (10, 20, 30 and 60s).
to save and leave the menu level, or
to leave the menu level without saving.

This setting controls the duration of activation of NO/NC hardwired devices in case of alarm
If ON Until Disarm is set, the relay will be activated until the system becomes unset.
until the menu ‘2-6 Alarm Relay’ appears. The current setting is also displayed.
until the desired duration is displayed (2s, 30s, 60s, 180s, 300s and ‘ON Until Disarm’), and
to save and leave the menu level, or
to leave the menu level without saving.
This function, if activated, can exclude individual zones from alarming more than three times before the system is switched out of focus. If the function is not activated, there is no limit when triggering an alarm for a zone.
until the menu ‘2-7 Zone Lockout’ appears (“2-7 zone exclusion”). The current setting is also displayed.
Activate Zone Lockout (zone exclusion), or
, to turn off Zone Lockout (Zone Exclusion).
With this function, if activated, the system can be remotely controlled on the go via telephone.
until it appears in the menu ‘2-8 Remote Phone Control’. The current setting is also displayed.
Activate remote phone control (telephone remote control), or
to turn off Remote Phone Control.
This determines the number of incoming call signals that a connected telephone receives before the answering machine and/or remote control access is switched on.
Enter the desired number of call signals (1-30) before the radio center accepts the call.
to save and leave the menu level, or
to leave the menu level without saving.
This function, if activated, delays the action of the telephone dialing device by 30 seconds so that in case of an alarm the system can still be switched out of focus and no call is made.
until the menu ‘2-10 Dial Delay’ appears. The current setting is also displayed.

to turn on "Dialler Delay", or
to turn off "Dialler Delay".
This function can be used to set the dial method with which the telephone dialing device is dialed/connected.
until the menu ‘2-11 Dial Method’ appears. The current setting is also displayed.
through the possible options (Tone/DTMF and Pulse) until the desired setting appears in the display,
to save and leave the menu level, or go with
to leave the menu level without saving.
until the menu ‘2-12 Dialer mode’ (selection mode) appears. The current setting is also displayed.
through the possible options (Voice Dialler and Remote Manager) until the desired setting appears in the display.
to save and leave the menu level, or
, to leave the menu level without saving.
Go with them


until the menu ‘3. ‘ZONE SETUP’ (ZONS-CESSING) appears and presses
Go to the zone number that you want configured and press
The following configuration options are available for Zone 1. The options for all other zones (2-10) are identical, except that the jurisdiction number of the zone changes according to the zone to be set.
to get to the first menu level.
until the menu ‘3-1 Z01 Name’ (Z01 name) appears. The current setting is also displayed.
through the possible options until the desired setting is displayed.
to save and leave the menu level, or
, to leave the menu level without saving.
Each alarm zone can be programmed according to one of the five modes mentioned below, depending on which type of alarm is triggered. The following types are possible:
24-hour monitoring to trigger alarm in case of a “Personal Attack” (PA). The act shall:
Go with · Panic/PA (Panic/PA)

A PA switch immediately triggers a full alarm.
Provides standard intrusion monitoring with normal sharp/partial sharp functions.
24 Hour Intruder (24 hours burglary)
provides 24-hour monitoring for areas that need to be constantly monitored, even if the system is fuzzy (e.g. A gun cabinet. If a detector of this zone is activated, it immediately triggers a full alarm.
Provides 24-hour monitoring by fire/smoke detectors that can be integrated into the system. If a detector triggers, then immediately a full alarm is triggered.
If the system is set to high alert, each triggered detector in the zone will cause an entry into the event log without alarming.
until the menu ‘3-2 Z01 Type’ (Z01 type) appears. The current setting is also displayed.
through the possible options until the desired setting is displayed.
to save and leave the menu level, or
, to leave the menu level without saving.
If turned on, each triggered detector of the zone will clear the further delay time during the initial delay and turn the system to be active 5 seconds later.
until the menu ‘3-3 Z01 Final Exit Set’ appears (Z01 Start setting). The current setting is also displayed.
, to switch on the initial setting of the zone; or
, to turn off the initial setting of the zone.
This checks whether the zone’s gong function is available.
until the menu ‘3-4 Z01 Chime’ (Z01 Gong) appears. The current setting is also displayed.
, to turn on the zone's gong function; or
to turn off the zone's gong function.
until the menu ‘3-5 ENTRY DELAY’ appears. The current setting is also displayed.

On/Off Status (On/off damming)
until the menu ‘3-5-1 Status’ appears. The current setting is also displayed.
, to switch on the zone access delay; or
, to turn off the zone access delay.
until the menu ‘3-5-2 Delay Time’ appears.
Enter the desired delay time (10 to 250s).
to save and leave the menu level, or
, to leave the menu level without saving.
to return to the first menu level.
This sets the zones that are active in partial sharp circuit 1 when partial sharp gate 1 has been turned on.
until the menu ‘3-6 Z01 Part-Arm 1’ (Z01 part sharpness 1) appears. The current setting is also displayed.
, to switch on the zone in partial sharp circuit 1, or
, to switch off the zone in partial sharp circuit 1,
This sets the zones that are active in partial sharp circuit 2 when partial sharp gate 2 has been turned on.
until the menu ‘3-7 Z01 Part-Arm 2’ (Z01 part sharp 2) appears. The current setting is also displayed.
, to switch on the zone in partial sharp circuit 2, or
, to switch off the zone in partial sharp circuit 2 .
until the menu ‘3-8 Z01 Wlk Thru’ (Z01 DURCHGANG) appears. The current setting is also displayed.
through the possible options (Off, Entry-Door and Entry route) (OFF, Access Door, Access Route), until the desired setting is displayed.
to save and leave the menu level, or
Delay period (delay time) · Go with

, to leave the menu level without saving.

until the menu '4. ‘VOICE DIALER SETUP’ (TELEFONSELECTOR) appears and presses
to return to the first menu level.
until the menu ‘4-1 PHONE NUMBERS’ appears and press
until the desired telephone number (1-4) appears in the menu. The current setting of each phone number is also displayed.
To change the numbers, press
Enter the new phone number (32 numbers max)
to save and leave the menu level, or
, to leave the menu level without saving.
, to enter a 3.5s break in the dial sequence.
Move the cursor to the left.
Move the curor to the right.
to delete the characters under the cursor.
Press and hold them
to delete the whole phone number.
After you have programmed all the phone numbers that you want, press
to return to the first menu level.
Size

This means the entire time in which the alarm message is played and repeated when a call executed by telephone dialing device is accepted.
until the menu ‘4-2 Message Play Time’ appears. The current setting is also displayed.
through the possible options (50, 70, 90 and 110s) until the desired setting is displayed.
to save and leave the menu level, or
, to leave the menu level without saving.
until the menu ‘4-3 RECORD VOICE’ appears and press
through the possible options until the desired message type is displayed, which should be recorded.
a) Main alarm message, (12 seconds max. 12s
b) Intruder alarm message, (4 seconds max). 4s
c) Fire alarm message, (4 seconds max). 4s
d) Panic/PA alarm message, (4 seconds max). 4s.
To record a new message, press
to start recording the voice message. When you have finished recording, the voice message is automatically repeated; or
to leave the menu level without change.
, to stop the recording and delete the remaining recording time.
to return to the first menu level of the telephone dialing device. .
UNTIL IN THE MENU ‘4-4 REPLAY ALARM MESSAGES’ (REPEAT ALERT MESSAGES)
Appears and presses
through the possible options until the desired message type is displayed.
a) Main + Intruder Messages (main and burglary messages)
b) Main + Fire Messages (main and fire messages)
c) Main + Panic/PA Messages (main and panic/Pac messages)
To repeat the message, press
to return to the first menu level in the telephone dialing device.
This function controls which phone numbers should be called if the telephone dialing device is activated.
The order of the stored telephone numbers is displayed with the digits 1-4. An “X” means the number is
Go with · Walk with · Go with

Not unlocked and an “O” means the number is unlock. If e.g. the “OOOX” is displayed, numbers 1-3 are called in sequence and number 4 cannot be called.
Workplace setting: All numbers disabled.
until the menu ‘4-5 CALL ROUTING’ appears. The current setting is also displayed.
by the possible options until the desired phone numbers (1-4) that are to be configured appear. The current setting is also displayed.
to turn on the number in order, or
, to turn off the number in order.
, to get to the “Voice Dialler Setup” menu level.
This sets the number of phone numbers to be confirmed that stop the telephone dialing device. If you e.g. “2” is set, the call order will continue to run until a call acknowledgement has been received from 2 different numbers (e.g. by telephone numbers 1 and 3.
until the menu ‘4-6 Tel Confirm Times’ appears. The current setting is also displayed.
To change the settings, press
Enter the desired number (1-4).
to save and leave the menu level, or
, to leave the menu level without saving.
This sets the maximum number of call attempts that the dialer dials in the call order.
until the menu ‘4-7 Call Attempts’ appears. The current setting is also displayed.
Enter the desired number (1-5).
to save and leave the menu level, or
, to leave the menu level without saving.
Go with them


up to the menu ‘5. ‘FULL ARM SETUP’ (SET FULL ALARM) Appears and presses
, to get back to the first menu level.
up to the menu ‘5-1 EXIT-DELAY’ appears. The current setting is also displayed.
On/Off status (on/off status)
up to the menu ‘5-1-1 Status’ appears. The current setting is also displayed.
, to switch on the output delay; or
, to switch off the output delay.
up to the menu ‘5-1-2 Delay Time’ appears. The current setting is also displayed.
Enter the desired delay time (10 to 250s).
to save and leave the menu level, or
, to leave the menu level without saving.
to return to the “Full Arm Setup” menu level.
5-2 ENTRY DELAY BEEP (input delay signal)
This is to control the warning sound (beep) that will be heard during input delay time when a full alarm is active.
until the ‘5-2 Entry Delay Beep’ (input delay signal) appears in the menu. The current setting is also displayed.
, to turn on the input delay signal; or
You · Delay period (delay time)

, to switch off the input delay signal.
This is to control the warning sound (beep) that will be heard during initial delay time when a full alarm is active.
until the ‘5-3 Exit Delay Beep’ menu appears. The current setting is also displayed.
, to turn on the output delay signal; or
, to switch off the output delay signal.

until the menu '6. PART-ARM 1 SETUP’ (STAKE THE PART ALARM) appears and presses
to return to the first menu level.
up to the menu ‘6-1 EXIT-DELAY’ appears. The current setting is also displayed.
On/Off status (on/off status)
up to the menu ‘6-1-1 Status’ appears. The current setting is also displayed.
, to switch on the output delay; or
, to switch off the output delay.
up to the menu ‘6-1-2 Delay Time’ appears. The current setting is also displayed.
Enter the desired delay time (10 to 250s).
You · Delay period (delay time)

to save and leave the menu level, or
, to leave the menu level without saving.
to return to the “Full Arm Setup” menu level.
6-2 ENTRY DELAY BEEP (input delay signal)
This is to control the warning sound (beep) that will be heard during input delay time when a full alarm is active.
until the menu ‘6-2 Entry Delay Beep’ appears. The current setting is also displayed.
, to turn on the input delay signal; or
, to switch off the input delay signal.
This is to control the warning sound (beep) that will be heard during initial delay time when a full alarm is active.
until the ‘6-3 Exit Delay Beep’ menu appears. The current setting is also displayed.
, to turn on the output delay signal; or
, to switch off the output delay signal.

until the menu '7. PART-ARM 1 SETUP’ (STAKE THE PART ALARM) appears and presses
to return to the first menu level.
up to the menu ‘7-1 EXIT-DELAY’ appears. The current setting is also displayed.
On/Off status (on/off status)
Size

up to the menu ‘7-1-1 Status’ appears. The current setting is also displayed.
, to switch on the output delay; or
, to switch off the output delay.
up to the menu 7-1-2 Delay Time appears. The current setting is also displayed.
Enter the desired delay time (10 to 250s).
to save and leave the menu level, or
, to leave the menu level without saving.
to return to the “Full Arm Setup” menu level.
7-2 ENTRY DELAY BEEP (input delay signal)
This is to control the warning sound (beep) that will be heard during input delay time when a full alarm is active.
until the ‘7-2 Entry Delay Beep’ (input delay signal) appears in the menu. The current setting is also displayed.
, to turn on the input delay signal; or
, to switch off the input delay signal.
This is to control the warning sound (beep) that will be heard during initial delay time when a full alarm is active.
until the ‘7-3 Exit Delay Beep’ menu appears. The current setting is also displayed.
, to turn on the output delay signal; or
, to switch off the output delay signal.
Delay period (delay time)


until the menu ‘8 TIME & DATE SETUP’ appears and presses
to return to the first menu level.
until the menu ‘8-1 Date’ appears. The current setting is also displayed.
Enter the date in the format ‘DD/MM/YY’.
to save and leave the menu level, or
, to leave the menu level without saving.
until the menu ‘8-2 Time’ appears. The current setting is also displayed.
Enter the date in the following format: ‘HH/MM/SS’.
to save and leave the menu level, or
, to leave the menu level without saving.
Size


until the menu '9. LATCH KEY SETUP’ (HOUSEKLE ASSESS) appears and
to return to the first menu level.
This sets the users who use the front door key. If you set Selected Users, the front door key will only work for those users selected in the 9-2 Selected user Setup menu.
until the menu ‘9-1 Status’ appears. The current setting is also displayed.
through the possible options (Off, Selected-Users and All-Uzers) until the desired setting appears.
to save and leave the menu level, or
, to leave the menu level without saving.
This gives you control over the users for whom the front door key has been selected.
UNTIL IN THE MENU ‘9-2 SELECTED USER SETUP’
Appears and presses
through the menu until the desired user number (1-6) that is to be set appears in the display. The current setting is also displayed.
to turn on the front door key for the user, or
Go with · go with

to turn off the front door key for the user.
After you have set all users as desired, press SIe
to return to the “Latch Key Setup” menu level.
until the menu ‘9-3 PHONE NUMBERS’ appears and press
through the menu until the desired telephone number (1-2) appears. The current setting is also displayed.
Enter the new phone number (max). 32 digits.
to save and leave the menu level, or
, to leave the menu level without saving.
, to build in a 3.5s break during the dial process.
to move the cursor to the left.
to move the cursor to the right.
to delete the character under the cursor.
to delete the complete phone number.
After you have programmed the desired phone numbers, press
to return to the “Latch Key Setup” menu level.

until the menu ‘11. ‘ANSWER PHONE SETUP’ (SETTING ANSWERING MACHINE)
Appears and presses
to return to the first menu level.
until it appears in the menu "11-1 Status". The current setting is also displayed.
to turn the answering machine on, or
Go with them

to turn off the answering machine.
until the menu ‘11-2 Record Greeting’ appears.
To receive the new welcome, press
, to start the voice recording (max. Duration:12s. When you have finished speaking, the announcement is automatically repeated or
to leave the menu level without change.
, to stop the recording and delete the remaining time.
until the menu ‘11-3 Replay Greeting’ appears.
To repeat the greeting, press

until the menu ‘12. ‘REMOTE MANAGER SETUP’ (SET REMOTE CONTROL)
Appears and presses
to return to the first menu level.
until the menu ‘12-1 Phone No:’ (phone number) appears. The acous setting is also displayed.
Enter the new phone number (max). 32 digits.
to save and leave the menu level, or
, to leave the menu level without saving.
, to build a 3.5s break in the dial sequence.
to move the cursor to the left.
to move the cursor to the right.
to delete the character under the cursor.
to delete the complete phone number.

until the menu ‘12-2 Unit ID No:’ appears. The current setting is also displayed.
Enter the system code (max). 4 digits) which you receive from the service company. (Please do not confuse this with the system house code).
To enter the ID code "B", press
To enter the ID code “C”, press
To enter the ID code “D”, press
To enter the ID code “E”, press
To enter the ID code “F”, press
to save and leave the menu level, or
, to leave the menu level without saving.
This sets the maximum number with which the dialer tries to contact each phone number of call order that is switched on.
until the menu ‘12-3 Call Attempts’ appears. The current setting is also displayed.
Enter the desired number (1-5).
to save and leave the menu level, or
, to leave the menu level without saving.

Control Panel Remote Control
Part arm 1 (partial sharpness 1)
Part arm 2 (partial sharpness 2)
Chime On/Off (Gong on/off)
Keypad Beep Mute On/Off
PA (personal). Attack
(hold for 3s) slide PA switch up
LED Indicators:
Off (Off) Flashing (Blinking Lights) On (On)
POWER No power Battery powered Mains Powered
Operation Off-Operation Battery operated socket operation
LOW BAT Detector batteries OK PIR detector battery low MAG detector battery
Low battery battery OK battery motion detector low battery magnetcont. Low
When buildings are abandoned, the system should be switched to sharpness. Before doing this, check that all windows and doors are closed and that the motion detectors are not blocked. Make sure pets can only be in areas that are not protected by a motion detector.
The system can be set in three alarm positions: sharp, partially sharp 1, partly sharp 2. The partial sharpness setting allows you to leave selected areas out of focus while the remaining parts of the system are set.
If the system is switched to a state of readiness (no matter in which alarm position), the radio control center will display the alarm position and the status of the front door key for several seconds. If turned on, the “countdown” of the initial delay time is displayed. As soon as the output delay time expires, a beep sounds from the central station with an increasing clock number, the further the time elapses. At the end of the initial delay time, the system is then switched to a live state. At this time, the user must have left the building and closed the exit door.
If a detector of an active zone is triggered in the case of a system with a sharp switch, if it is turned on, the programmed initial delay time for this zone will start a “countdown” and display it on the display. If the access delay time expires, a beep sounds from the central station as the clock number increases, the further the time elapses. If the system is not switched to be unsharp until the expiry of the access delay time, an alarm will be triggered. If the access delay of an activated zone is not switched on, without

Delay, immediately triggered alarm.
Upon expiration of the programmed alarm period, the internal siren of the radio control center will cease and the system is automatically switched back to live.
In the event of a triggered alarm and an activated telephone dialing device, the first unlocked call number in the call sequence is called up and the recorded voice message is received according to the entered “Play Time”
(playback time) repeated. The call receiver should receive the message by pressing the button
on the phone to stop another activity of the dialing device. If no acknowledgement of receipt is made, the next number of the programmed call sequence will be called. The telephone dialer will continuously call any unlocked number until either all numbers in the calling sequence have been called (according to the programmed ring count) or until a receiver has confirmed the message.
POOR (SHARP)
The system can be set to the tune either by means of a handheld radio transmitter or at the control center as follows:
Remote control (radio handheld transmitter):
The radio control center will emit a received signal in the form of a beepton.
Control Panel (Radio Center):
The system can be switched either with the aid of a radio handheld transmitter or at the radio control center as follows:
Remote control (radio handheld transmitter):
Press the “Partially Specified” button
The radio control center will emit a received signal in the form of a beepton.
Control Panel (Radio Center):
The system can be switched either with the aid of a radio handheld transmitter or at the radio control center as follows:
Remote control (radio center):
Press the “Partially Specified” button
The radio control center will emit a received signal in the form of a beepton.
Control Panel (Radio Center):
The system can be switched out of focus either with the aid of a handheld radio transmitter or at the control center as follows:
Remote control (radio handheld transmitter):

The radio center will emit a received signal in the form of a beepton.
Control Panel (Radio Center):
If the system is switched to a fuzzy state and the LED light ‘ALARM MEM’ (alarm indication) glows with simultaneous beep of the control center at a distance of 10 s, it shows you that an alarm has been triggered.
, to turn off the lighting of the LED and beep.
To use the Quick setting and set the plant to 5s, skip remaining initial delay time as follows:
First, bring the plant to the desired mode (i.e. Full Arm, Part-Arm 1 or Part-arm2 (Full alarm, part alert)
1 or partial alarm 2), as described above and then press
To cut out a zone from the next alarm,
until the desired zone appears in the menu. The current setting is also displayed.
to leave the zone (i.e. zone omit ON) (e.g. Zone recess AN.
to activate the zone again (i.e. zone omit OFF) (e.g. Zones of the exclusion.
After you have completed the setting for the desired zone recess, press
Return to standby mode.
A full alarm can be triggered immediately in any mode (whether the system is switched sharp or out of focus) in case of a personal threat or danger, either by the switch on the radio handheld transmitter or the radio control center.
Remote control (radio handheld transmitter):
Push the PA switch up.
Control Panel (Radio Center):
and hold the button for approx. 3 seconds pressed.
The alarm will sound until the set alarm duration has elapsed or the system is switched out of focus again.
If the battery cover of a device is opened or the radio control center is removed from the wall, a full alarm will be triggered immediately even if the system has been switched out of focus. The alarm signal will either sound according to the set alarm duration or until the system is switched off again. The LED light ‘ALARM MEM’ (alarm warning) on the radio control center will illuminate and the control center emits beeps to indicate that an alarm has been triggered.
The Gong function can only be used in standby mode.

, to switch back and forth between ON/OFF (ON/Off).
The event protocol detects and stores the last 50 events (setting, unsettling circuits, alarm and detector battery weaknesses). The log records the time, date and details of Jade’s event. If, while the system is fuzzy, the LED “ALARM MEM” lights up and the control center beeps every 10 s, this means that an alarm has been triggered. To stop the LED and beep, you have to go into the log book (event log).
To access the event log (during standby mode), press
The log book will automatically display all events starting with the last one. The data of each event is displayed on two areas, each one appears for 5 seconds before the next area/event is shown.
You can display the desired events manually.
to return to standby mode.
To record a message (max.) 30s Duration), use the message recording function on the control center as follows:
to start the recording.
During recording, press
to stop the recording and delete the remaining time.
If 6 messages have already been recorded, no further voice message can be recorded until a message is deleted.
Access to the message announcement can be obtained either via the radio control center (see Message Repetition) or through the function on the radio operating field.
If the ‘message’ LED lights up, this shows that either a new message is on the answering machine or the message announcement and has not yet been listened to. You can access the recorded messages at the control center as follows:
The messages are played back, starting with the last one recorded. Press
To get to the end of the news.
At the end of each message, there is a possibility to delete the just listened-up message.
To delete the message
to confirm the deletion and actually remove the message.
, to undo the deletion process and get to the next message.
After all messages are played, the system automatically switches back to standby mode.
When the remote control function is switched on, the system receives the call after the programmed number of ringing tones and outputs three beeps, whereupon the caller is asked to enter the user code on the telephone keyboard.
A valid user code is confirmed by a long beep. An invalid code is signaled by two short beeps.

If the user code is not entered within 30 s or an invalid code is entered more than three times, the central control unit automatically terminates the connection.
Use of an external answering machine:
If the remote control is used in conjunction with an external answering machine, you must consider the following points:
An answering machine, as otherwise the central station always takes up the call before
Turns on answering machine.
To access the telephone remote control, the central office has a “double dial-in” function to enable the central station to answer the call before the external answering machine turns on. This procedure is as follows:
Take the ringer.
The following functions can be set via the telephone remote control. The system will confirm each signal with a long beep.
, to switch sharply.
, to switch partly sharp-1.
, to switch partly sharp-2.
to make the system fuzzy.
to stop the siren.
to turn on the siren.
, to listen through the microphone of the control center.
to stop listening.
, to query the system status. The status is repeated at the 2s interval for 15s.
, to reproduce messages from the answering machine.
When a message is being played, press
for 2 seconds to get to the end of the message and listen to the next one.
to delete all messages of the answering machine.
, to terminate the connection with the radio control center.

All devices that belong to the radio alarm system continuously monitor their battery status. The radio control center also monitors the battery ratios of all wireless motion detectors and magnetic contacts. If the battery status falls below an acceptable level, “lower battery status” is activated. In addition, it is displayed at the radio control center and recorded in the event memory if a wireless motion detector or magnetic contact has low battery status.
If a low battery status has been activated, the device will normally continue to function for up to 2 weeks (depending on system use). Nevertheless, the battery for each device should be replaced as soon as possible.
A low battery status is displayed on the devices as follows:
During the phase in which the control center is not connected to a socket, the control station is supplied with rechargeable backup batteries.
Under normal battery status, the Power LED light will be lit at 1s on the control center. At low battery status, the Power LED will light up at 3s intervals.
If the radio handheld transmitter operates only with a low battery status, the transmission LED continues to light after actuation of a button even after the button has been released again.
Under normal battery status, the transmission LED goes out again after releasing the button.
PIR Movement Detector (PIR Radio Motion Detection)
If the radio motion detector is operating with only a low battery status, the LED lights up behind the monitoring lens to signal that the battery must be renewed.
Under normal battery status, the LED will not light unless the radio motion detector is in “Walk Test Mode”.
Magnetic contact detector (radio magnetic contact)
If the radio magnetic contact operates only with a low battery status, this is indicated by the transmission LED which can be used for approx. 1 second after window/door has been opened.
Under normal battery status, the LED will not light up when magnetic contact has been activated (unless the detector is in test mode with the battery cover removed)
Control Panel (Radio control centre) · Remote control (radio handheld transmitter)

Your plant requires only a small amount of maintenance. However, a few things should be considered so that your plant works reliably.
The rechargeable batteries have an expected lifetime of approx. 4 years and do not require any maintenance during this time, except that they are charged. The batteries are damaged if they are stored with empty status for a long time.
The detectors also require only a small amount of maintenance. Batteries should be renewed once a year or if low battery status is indicated.
Before you remove the battery covers or open the control panel, make sure that the system is put into test mode to prevent a full alarm from being triggered.
The specific requirements for the batteries are as follows:
At the end of battery life, batteries should be disposed of in accordance with regulations. Do not dispose of them together with your household waste. DO NOT BURN IT AT ALL.
The rechargeable batteries contain Sulphuric Acid – DO NOT OPEN THE Housing.

Fill in the following boxes during installation to have an overview of future applications when expanding your plant and as a help with possible problem management.

You can then also write down user codes and installation access code.
Use the above representation to get your house code etc. to be recorded.
This information shall be kept confidential and in a secure place.

Central does not work – Power LED OFF (OFF) or lights up.
The telephone dialing device is not working.
The LED at Line Status flashes and the system makes beeps.
Phone dialing device does not respond to an alarm
Answering service does not respond or receive messages
Voice message cannot be recorded at central station.
The radio control center does not contact the service guard in case of an alarm
Radio control center does not respond to telephone remote control from the road
Symptom / Recommendation

Door key (latch-key) does not work if the system is fuzzy
Radio control center does not accept the user access code.
Radio control center does not respond to radio detector
A full alarm was triggered, although the system is fuzzy and has not been triggered.
a. Check all battery covers to see if they are mounted correctly.
b. Check that the control center is properly mounted on the wall and the sabotage switch is closed.
LED of the handheld radio transmitter does not light or only faintly when the device is working
PIR radio motion detector triggers false alarm
PIR radio motion detector does not respond to a movement.

PIR radio motion detector LED lights up when monitoring movement (device is in the normal mode.
Radio magnetic contact does not work.
a. Make sure the jumper link has been removed.
b. Make sure the extra contact is wired properly.
c. Make sure that the magnet is correctly aligned with the detector and that the distance between the magnet and the detector is not too large (see instructions from external magnetic contacts).
Note: If you are using an additional wired detector, please note that windows/doors monitored by both detectors (wired or wireless) closed if an extra contact is used then the doors/windows protected by both the main wirefree detector and the additional wire detector must be closed when either is opened. If one of the doors/windows is already open then the opening of the other door/windrow will not be detected.
Radio magnetic contact triggers false alarm
LED of the radio magnetic contact lights up when window/door is opened
The solar exterior siren triggers an alarm without the system being sharp. The sound is reproduced, which also when the sabotage switch is triggered,

You can extend your system to provide additional monitoring and protection by installing extra radio magnetic contacts, wireless motion detectors, radio control panels, handheld transmitters and exterior siren.


If you cannot handle a problem independently, please call the hotline:
0900 1290468 (0,93 € / Minute)
(Mondays to Thursdays from 07:30 until 16:00, Fridays from 7:30 to 13:00)
Most problems can be solved quickly on the phone.
You also have the option to send us an email at the following address:
GUARANTEE
This product (except the batteries) has a two-year warranty on materials and operating activity from the date of purchase. We will repair or replace any defective product. No liability can be for wear,
Negligence of the buyer, improper assembly or use, local radio interference, intentional or
unintentional damages are assumed. This guarantee does not affect your positive rights.
If an appliance is defective, the product must be sent in adequate packaging to the address below.
returned with:
If you are sending in a system, make sure that all batteries have been disconnected/interrupted and that the
The device is adequately packaged so that no damage can occur during transport.
For security reasons, it is recommended to send by registered mail.
Am Hammer 10, 51647 Gummersbach, Germany
Novar GmbH a Honeywell Company Office Northern Europe Business Unit Friedland Brodhausen 1, 51491 Overath
Novar Electrical Devices and Systems.
The Arnold Centre, Paycocke Road, Basildon, Essex. SS14 3EA. UK
Phone: +49 (0) 2204 - 76717 - 0 Fax: +49 (0) 2204 - 76717 - 10
Our research and development department is continuously developing new products.
We practice a policy of continuous improvement and reserve the right to change specifications without prior notice.







Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.