EN
Friedland logo
Official user manual

Friedland SA5F

64 pages·2.6 MB·Security·PDF·ENDEFRITNLJA
Friedland SA5F
Table of Contents 80 sections SA5F · Wireless alarm system for 6 zones · With integrated telephone dialing device · Manual of installation and operation · … ShowHide
SA5Fp.1Wireless alarm system for 6 zonesp.1With integrated telephone dialing devicep.1Manual of installation and operationp.1Forewordp.2IMPORTANTp.2IMPORTANT:p.2Local regulations and lawsp.2SYSTEM SECURITYp.2SAFETY STATEMENTp.2ENGLISH MENU TOURp.3TRANSLATIONp.3CONTENTp.5SET CONTENT 7p.5INTRODUCTION AND OVERVIEW 9-11p.5PLANNING AND EXTENSION OF THE RADIO ALARM SYSTEM 12p.5RADIO HANDHELD TRANSMITTER 13p.5RADIO CONTROL CENTER 14p.5PASSIVE INFRARED (PI) RADIO MOTION DETECTORS 17-20p.5RADIO MAGNETIC CONTACTS 20 - 23p.5EXTERNAL CONNECTIONS 24p.5TESTING THE SYSTEM 25p.5FACTORY SETTINGS 27p.5PROGRAMMING 29p.5INSTRUCTIONS FOR USE 49-54p.6MAINTENANCE 55p.6RECORDING ALARM MESSAGE 56p.6PROBLEM MANAGEMENT 57p.6EXTENSION OF THE ALARM SYSTEM 60p.6SPECIFICATION OF THE DEVICES 62p.6SET CONTENTp.7EXTENSION OF THE RADIO ALARM SYSTEMp.8INTRODUCTION AND OVERVIEWp.9Multiple usersp.9CIRCUIT SHARPENING SYSTEMp.9DELAY ON ACCESS/EXITp.9ZONESp.9ZONE LOCKp.9FAST SETTINGp.9LAST OUTPUT ZONE SETTINGp.10TRANSIT ZONEp.10OMIT ZONE (OMIT ZONE)p.10EVENT LOGp.10GONGp.10TELEPHONE DIALING DEVICEp.10Recognition of change in alarm status over telephone (LATCH-KEY)p.10RESPONSE-HANDLING MACHINEp.10MESSAGE STORAGEp.10TELEFON remote control of the system (on-the-go)p.11SABOTAGE PROTECTIONp.11RADIO EARLY DETECTIONp.11BATTERY STATUS INDICATORp.11SYSTEM HOUSE CODEp.11PLANNING AND EXTENSION OF YOUR ALARM SYSTEMp.12RADIO HANDHELD TRANSMITTERSp.13SETTING UP THE RADIO HANDHELD TRANSMITTERp.13RADIO CONTROL CENTREp.14POSITIONING OF THE RADIO CONTROL CENTREp.14INSTALLATION OF THE RADIO CONTROL CENTREp.15CONFIGURING THE HOUSE CODING OF THE RADIO CENTERp.16RADIO CONTROL CENTER AND RADIO HAND TRANSMITTER TESTp.16POSITIONING THE PIR RADIO MOTION DETECTORp.17INSTALLATION AND CONFIGURATION OF THE PIR RADIO MOTION DETECTORp.18DIP 1 DIP 2 DIP 3p.18TEST OF THE PIR RADIO MOTION DETECTORp.19RADIO MAGNETIC CONTACTp.20POSITIONING OF THE RADIO MAGNETIC CONTACTp.20INSTALLATION AND ADJUSTMENT OF THE RADIO MAGNETIC CONTACTp.20DIP 9 DIP 10 DIP 11p.22TESTING RADIO MAGNETIC CONTACTp.22EXTERNAL CONNECTIONSp.24SYSTEM TESTp.25First testp.25TESTING THE INSTALLED SYSTEMp.25WALK TESTp.25ALARM TESTp.26SOLAR SIREN SERVICE MODE FOR SOLAR OUTSIDE SIRENp.26TELEPHONE DIALING TESTp.26FACTORY SETTINGSp.27Part-Arm 2 Setup (Partially Setting)p.28
Page 1 of the Friedland SA5F user manual — Manual of installation and operation
Page 1 · click to enlarge
Page 1
Friedland SA5F — SA5F diagram (page 1)
Fig. 1

SA5F

Wireless alarm system for 6 zones

With integrated telephone dialing device

Friedland SA5F — SA5F diagram (page 1)
Fig. 2

Manual of installation and operation

Page 2 of the Friedland SA5F user manual — SAFETY STATEMENT
Page 2 · click to enlarge
Page 2

Foreword

All components of this wireless alarm system are manufactured to provide a high level of security, durable and reliable.

No radio licence is required for these devices. Radio reception characteristics could be affected by other signals. Further information can be found in the chapter Radio interference protection.

The radio-controlled devices in this system have been tested by an independent approved laboratory for R&TTE compliance of radio-guided devices.

The system is designed to be easy and installed with conventional tools. Nevertheless, it is important that the installer reads the manual before installation so he understands the procedure.

During installation, it is important to follow the detailed procedure from the manual.

This manual should be kept safe for future needs.

IMPORTANT

All components (except for radio external sirens) are only suitable for installation in a dry interior.

You need the following tools and materials:

5 and 6mm dowels

IMPORTANT:

Local regulations and laws

The system should be based on local or national regulations and laws are installed and operated. We recommend that you refer to the location or apply nationally applicable rules to the competent authority. We would like to point out that the devices of this series are not VDS tested! No liability or reimbursement of costs for damages incurred can be assumed!

SYSTEM SECURITY

This system is designed to detect burglars when installed correctly, but also has a strong deterrent effect on possible burglaries.

Please note, however, that with appropriate expertise and time each alarm system must be overcome and we therefore recommend the use of an alarm system always in conjunction with good physical protection such as e.g. Safety fittings for windows and doors.

All devices in the system are matched with an 8-bit house code and configured by the user/installer to use a unique identification code for installation. The system house code can be changed by the user at any time.

The system may be controlled by one or more remote controls or the central processing unit.

You should make sure that you do not lose your remote control and the user code for the central unit is not made known to other people, as this can affect the security of the system. In both cases, the system house code and user code should be changed as soon as possible.

SAFETY STATEMENT

Please always follow the manufacturer’s instructions when using tools, ladders etc. use and wear protective equipment (e.g. goggles) when you drill holes. Before drilling holes into the wall, please check if hidden cables and water pipelines could be hit.

If you use a ladder, please ensure that it is placed on stable ground at the correct angle and secure.

The use of earmuffs is advisable if you work near the siren, as it emits high and loud tones.

Screwdriver · Drills · Ahle / Pfriem

Page 3 of the Friedland SA5F user manual — TRANSLATION
Page 3 · click to enlarge
Page 3

ENGLISH MENU TOUR

The menu on the LCD display is in English. The words are translated into German in this manual and stand in brackets behind the English word. But: Don’t worry, many words (ON, OFF, Replay, User...) you already know from other devices (such as e.g. Your video recorder.

For a better overview, the following terms are listed and translated alphabetically here:

TRANSLATION

EnglishGerman 24 Hour Intruder24-hour burglars Access codeAccess code Alarm DurationAlarm duration Alarm messageAlarm messages Alarm RelayAlarm Relays Alarm testAlarm test All usersAll users Answer PhoneResponding machine Anti-Tamper SwitchSabotage protection ArmSharp Back doorFront door Back LightBackground lighting BatteryBattery Battery clipBattery holder Battery monitoringBattery monitoring Bedroom 1Bedroom 1 Bedroom 2Bedroom 2 Bedroom 3Bedroom 3 Bedroom 4Bedroom 4 Call AtemptionCall attempts Call ConfirmsClock confirmation Call routingCall order ChimeGong Control panelControl panel DateDate Detector RangeMotion detector range Dial delaySelection delay Dial methodSelection method Dialler ModeSelection mode Dining doorDining room (dining room) DisarmFuzzy DownstairsBelow Entry DelayInput delay Entry Delay Beepinput delay beep tone Event logEvent log Exit Delay BeepInitial learning beep External Solar SireneExternal Solar Sirene Final ExitLast exit Fire/SmokeFire/Smoke Front doorFront door Greeting messageWelcome message HallCorridor Hardwired Siren TestWired Siren Test (Siren in the control panel) House Code Dip SwitchesHouse code dip switch IntrudersThe burglar Jumper LinkConnecting bridge KitchensKitchen LandingFloor heel, stairwell
Page 4 of the Friedland SA5F user manual — ENGLISH MENU TOUR
Page 4 · click to enlarge
Page 4
Latch keyDigital house key function Learn House CodeLearning the House Code Living roomLiving room LoungeRoom space Low Bat.Low battery Magentic contact detectorMagnetic contact Magnetic contactMagnetic contact Master User Access CodeMain user access code Message Play TimeMessage announcement time MuteSilent No nameNo name OFFExcise Omit ZoneZone of inactivity ONOne Panic/PAPanic fear Part-arm 1Partial sharpness 1 Part-arm 2Partial sharpness 2 Patio doorChange door Personal AttackPersons attack Phone NumbersTelephone numbers PIR DetectorMotion detectors PIR Movement DetectorMotion detectors Power Supply Jack SocketPower plug connector Qick SetQuick setting Relay testRelay test Remote controlRadio Hand Transmitter Remote managerRemote control of the alarm system by telephone RF Jamming DetectionRadio interference protection Rings to Answer PhoneNumber of call signals Security Manager ServiceSurveillance service Selected user setupSelected User Setting ShedShed/house TampersSabotage / Manipulation Terminal blockConnection terminals TimeTime Transmit LEDLight-emitting diode UpstairsAbove UsersUsers Voice DaillerTelephone dialing equipment Voice MemorySpokes message Walk testGo or Run Test Walk troughTransit zone Windows 1Window 1 Windows 2Window 2 Windows 3Window 3 Wirefree Siren TestRadio external siren test Zone LockoutRestriction zone
Page 5 of the Friedland SA5F user manual — PROGRAMMING 29
Page 5 · click to enlarge
Page 5

CONTENT

SET CONTENT 7

INTRODUCTION AND OVERVIEW 9-11

Multiple user installation sharply switch input/output delay zones lock-off zone Quick setting Last output zone setting Transit Zone Injunction Zone Event Protocol Gong telephone dialer latch key (Digital house key function) Answering machine Message recording Telephone remote control of on the go sabotage protection Radio early detection battery status indicator system home code

PLANNING AND EXTENSION OF THE RADIO ALARM SYSTEM 12

RADIO HANDHELD TRANSMITTER 13

Basic information setting of the radio handheld transmitter

RADIO CONTROL CENTER 14

Positioning of the radio control center Installation of the wireless control center 15 Setting of the Radio control center 16 Testing of said radio control station and of said handheld transmitter 16

PASSIVE INFRARED (PI) RADIO MOTION DETECTORS 17-20

Positioning of the PIR radio motion detector Installation of the pir radio motion sensor Setting of the PIr radio motion indicator Testing of PIR wireless motion detector

RADIO MAGNETIC CONTACTS 20 - 23

Positioning of the Radio Magnetic Contacts Installation and adjustment of the radio Magnetic contacts Testing of radio Magnetical Contacts

EXTERNAL CONNECTIONS 24

TESTING THE SYSTEM 25

Initial test testing of the installed system

FACTORY SETTINGS 27

Changes to factory settings

PROGRAMMING 29

User setting 29 System setting 30

Page 6 of the Friedland SA5F user manual — MAINTENANCE 55
Page 6 · click to enlarge
Page 6

Zone setting 35 Set telephone dialing device 38 Set full-sharp 40 Part-Sharp 1 Set 42 Part-shirl 2 Set 43 Time and date 44 Set Latch Key - Setting 45 answering machine – Set 46 Phone remote control on the go - Set 47

Friedland SA5F — INSTRUCTIONS FOR USE 49-54 diagram (page 6)
Fig. 3

INSTRUCTIONS FOR USE 49-54

Basic system sharp switching System partially sharp switch (part arm 1) System part sharp switch system unsharp Switch Quick setting cease-and-desist zone panic function sabotage protection Gong event protocol message recording remote control by phone from the road battery status indicator

MAINTENANCE 55

RECORDING ALARM MESSAGE 56

PROBLEM MANAGEMENT 57

EXTENSION OF THE ALARM SYSTEM 60

SPECIFICATION OF THE DEVICES 62

Page 7 of the Friedland SA5F user manual — SET CONTENT
Page 7 · click to enlarge
Page 7

SET CONTENT

The following components are attached to the scope of delivery of the alarm system:

1 x PIR radio motion detector

In addition,

Power adapter for the socket

Manual of installation and operation

Batteries, screws and dowels

Friedland SA5F — SET CONTENT diagram (page 7)
Fig. 4
Friedland SA5F — SET CONTENT diagram (page 7)
Fig. 5
Radio control centreRadio magnetic contact PIR radio motion detectorsRadio handheld transmitters
Show 4 more labels / short text on this page
1 x radio control center · 1 x handheld transmitter · 1x magnetic contacts · RJ11-RJ11 telephone connection
Page 8 of the Friedland SA5F user manual — EXTENSION OF THE RADIO ALARM SYSTEM
Page 8 · click to enlarge
Page 8

EXTENSION OF THE RADIO ALARM SYSTEM

With the following accessories you can expand your system and thus gain a higher degree of safety.

Art. designation Content

SU1F Two radio magnetic contacts and a handheld transmitter

More details about accessories can be found on page 60.

Show 5 more labels / short text on this page
SU2F Two radio motion detectors · SU3F Two handheld radio transmitters · SU4F Two magnetic contacts · RSPA · su5F Radio control panel · SUSFO external siren (solar operated)
Page 9 of the Friedland SA5F user manual — FAST SETTING
Page 9 · click to enlarge
Page 9

INTRODUCTION AND OVERVIEW

Multiple users

The system can be configured for up to 6 users as well as a main user.

This allows the event log to record which users have switched the system sharp and fuzzy. Each user receives a different access code. Additionally, a 4-second voice recording can be used to record the user’s name in order to use the latch key.

Only the main user has access to programming functions and is able to configure the system.

CIRCUIT SHARPENING SYSTEM

The system can be switched completely (Full ARM), i.e. for all zones sharp but also only partial sharpness (part arm).

Example:

The system could be configured to switch the system partly sharp during night, ensuring that only the ground floor and garage are set but you can move freely on the upper floor without triggering an alarm.

However, if the house is unoccupied, full focusing can ensure monitoring of all areas in the ground floor and upper floor.

DELAY ON ACCESS/EXIT

Each zone can be programmed to monitor either immediately or in delay mode.

Usually, the zones that monitor the entrance door and the routes to and from the radio control center are set to delay mode. This ensures that the user has sufficient time to leave the building after setting up control center or to fuzzily switch the system when he re-enters the building so as not to trigger an unwanted alarm.

The remaining zones are usually configured to trigger alarm directly and without delay.

Delayed alarm zones are only switched fully energized after the delay time for access/output has elapsed. Thus, if an alarm is triggered in a zone with delay, no alarm will be triggered until the time for access/output has elapsed.

If the system is not switched to be unsettled during the delay time, an alarm shall be triggered when the delay period has elapsed.

Zones without delay mode trigger alarm immediately when the system is switched to live.

ZONES

The system is designed for 6 wireless surveillance zones that independently of one another can accommodate different areas of a building or the like. You can monitor an apartment.

In addition to the actual protection against burglary, the following functions can be used:

- The Panic button can trigger an alarm for 24 hours in the event of immediate threat.

- 24-hour monitoring for special areas (e.g. Weapon cabinet

- 24-hour monitoring of smoke/fire development by integrating smoke detectors into the plant.

In addition, four hard-wired zones can be connected to the radio center that are configurable with the same characteristics as wireless zones (1 - 6).

ZONE LOCK

If an alarm of an active zone is triggered while the system is switched to a state of readiness, then an alarm will be triggered. After the programmed alarm duration has elapsed, the alarm stops and the system is automatically returned to its initial state. Subsequently triggered detectors will again trigger an alarm. If a single zone triggers an alarm more than three times, this zone is “locked” and radio signals from this zone are ignored until the system is switched out of focus.

FAST SETTING

With a quick setting, the system can be switched fully energized within 5 seconds if the programmed output delay is passed over. This can be useful if the output delay signal, which sounds in the form of a beepton, should end at night after only a few seconds.

Page 10 of the Friedland SA5F user manual — MESSAGE STORAGE
Page 10 · click to enlarge
Page 10

LAST OUTPUT ZONE SETTING

Triggering a detector of a last output zone during the initial delay extends the initial deceleration by another 5 seconds.

TRANSIT ZONE

This function could be used to briefly shut down the detectors of a zone that monitor the route between the main entrance door and the radio control center.

If the system is switched to a state of play and buildings/apartment are entered through the entrance zone, then the input delay works normally. All input zones are switched off to provide free access to the radio control center, in order to fuzzily turn the system before the input delay time of the input zone elapses and alarm is triggered.

The zone which is set as an input zone must be set with sufficient input delay time in order to reach the radio control center and switch the system out of focus.

OMIT ZONE (OMIT ZONE)

This function allows a zone to be omitted while the system is switched sharply. If the system is switched out of focus again, all recess zones are erased.

EVENT LOG

The radio control center is able to log the last 50 events of the system. This allows the user to see which user has switched the system sharp/unsharp and if and when an alarm was triggered. Time, date and details are recorded for each event.

GONG

The gong is a simple function for using the system in standby mode. If the gong setting is ON and a detector or zone reports a radio signal to the control center, a gong sounds. A typical application is this function when a door or a certain area should be monitored, but no loud siren should be triggered.

TELEPHONE DIALING DEVICE

A telephone dialing device is integrated into the control center, which serves to switch on the alarm message up to four numbers in case of a break-in (mobile phone, relatives, guard service etc.).

In the event of a break-in, the telephone dialing device (when enabled) will call the first input phone number in the sequence and report the received message for the set playback time. The recipient shall:

must confirm the message by placing the button

Press on the phone. If the call is not received or acknowledged, the next activated telephone number of the entered sequence will be called automatically. The telephone dialing device will dial each registered number until all the numbers have been dialed or are called. a call was received and confirmed beforehand.

Recognition of change in alarm status over telephone (LATCH-KEY)

If the system is fuzzy and the latch key function on, when entering the building, the telephone dialing device will call the first latch key phone number and reproduce the user message (which was entered for the user), namely for the set playback time. The recipient must confirm the message,

by placing the key

Press on the phone. If the call is not accepted or an acknowledgement of receipt has not been made, the second latch key telephone number will be dialed. The telephone dialing device continues to dial each number alternately until each number has been called according to the set call number or the sequence has been stopped/confirmed by the receiver.

For example, the latch key can be used to inform parents on-the-go when children have come from school and fuzzed their system.

RESPONSE-HANDLING MACHINE

The function of an answering machine is integrated in the radio control center. The answering machine records and stores a maximum of 6 messages with a limited call time of 30 seconds each.

Messages can be retrieved either directly from the radio control center or by a call to the system.

MESSAGE STORAGE

In addition, it is also possible to speak messages on the radio control center which can be tapped by others in order e.g. Save “subscription notes.” Any message can be max. It takes 30 seconds and counts as if

Page 11 of the Friedland SA5F user manual — SYSTEM HOUSE CODE
Page 11 · click to enlarge
Page 11

An incoming call message.

TELEFON remote control of the system (on-the-go)

It is possible to query the status of the system from on the go with the help of the telephone, but also basic settings (e.g. the setting/unsetting circuit. In addition, you can activate the microphone on the go to listen into the monitored rooms.

Also answering machine and message memory can be accessed from the road.

SABOTAGE PROTECTION

All devices (except the radio handheld transmitter) have sabotage protection to avoid unauthorized persons having unauthorised access to the devices in order to influence them. Any attempt to remove the battery cover from a device (except for handheld radio transmitters) or take off the control panel from the wall will trigger an immediate alarm (unless the system is in test or programming mode). This also occurs when the system is switched in a fuzzy manner. The optional radio external siren also has such sabotage protection, so that it cannot be torn down from the wall without alarming.

RADIO EARLY DETECTION

In order to alert the system against illegal radio interference signals, a special early detection has been integrated into the Radio Center.

If this function is set and the radio frequency continuously disturbed for 30 seconds (if the system is switched to a state of readiness), the Radio Center will emit an alarm in the form of beeps (permanently for 5 seconds). If the radio interference continues for another 10 or more seconds, a full alarm is triggered. This also happens if the system has been disturbed more than three times for 10 seconds over a period of 5 minutes.

Radio early detection is designed in such a way that it detects permanent interference signals. It cannot be ruled out that there may be local radio interference from systems operating legally or illegally on the same frequency. If you do not want to use radio early detection, we recommend that you observe the system at least two weeks in advance for possible radio interference (the radio early recognition must be switched on).

BATTERY STATUS INDICATOR

In addition to the battery monitoring and low-battery status display, the radio control center also indicates in the event log if wireless motion detectors or magnetic contacts have a low battery status.

SYSTEM HOUSE CODE

To prevent unauthorized users from influencing or If you are not focused, you must set your system to respond exclusively to radio signals from your own devices. This is ensured by setting the eight miniature DIP switches in all devices (except for central control), just like the ON/OFF combination of house code set by user/installer.

The radio control center is then programmed to respond exclusively to devices with house coding. All detectors and radio handheld transmitter/control panels must be set to the same house code in order for the system to function correctly.

In the radio motion detector, the radio magnetic contact as well as the radio handheld transmitter and the radio control panel are installed fields with 8 DIP switches each which must be set according to the house code.

Friedland SA5F — SYSTEM HOUSE CODE diagram (page 11)
Fig. 6
Examplehere is switch 1 on ON

The house code is set by setting the 8 DIP switches of each device according to the ON/OFF combination of the house code. When setting the switches, please make sure that each switch latches into the desired position. For this purpose, you can use the tip of a pin or screwdriver.

Page 12 of the Friedland SA5F user manual — PLANNING AND EXTENSION OF YOUR ALARM SYSTEM
Page 12 · click to enlarge
Page 12

PLANNING AND EXTENSION OF YOUR ALARM SYSTEM

The following example shows a typical building with the recommended positioning of radio control center, radio motion detector and radio magnetic contact. This should serve you, together with the recommendations in the user manual, as orientation during installation.

Friedland SA5F — PLANNING AND EXTENSION OF YOUR ALARM SYSTEM diagram (page 12)
Fig. 7

Before installing the alarm system, it is important to read the safety instructions and plan installation carefully.

The alarm system can be extended to ensure greater protection by e.g. additional PIR radio motion detectors, radio magnetic contacts or also radio control fields can be used. In addition, a solar-powered radio exterior siren is available.

Page 13 of the Friedland SA5F user manual — SETTING UP THE RADIO HANDHELD TRANSMITTER
Page 13 · click to enlarge
Page 13

RADIO HANDHELD TRANSMITTERS

The radio hand transmitter serves to switch the system sharp/partially-set and out of focus.

Friedland SA5F — RADIO HANDHELD TRANSMITTERS diagram (page 13)
Fig. 8

The radio handheld transmitter also has a panic button for direct threat. Pressing (sliding up) the panic button immediately triggers a full alarm, regardless of whether the system is switched sharp or out-of-focus. The alarm can be stopped by actuating the unset button or via the control center.

Any number of radio handheld transmitters can be used for system control as long as they are all set to the same house code.

The radio handheld transmitter is supplied with a CR2032 lithium button battery, which under normal circumstances lasts just over one year. Usually, the LED light on the hand transmitter only glows when a button has been pressed. If the battery status is low, however, this will be signaled by it continuing to light permanently after the button has been released again. In this case, the battery should be replaced as soon as possible.

SETTING UP THE RADIO HANDHELD TRANSMITTER

1. Remove the rear cover by screwing up the bolt.
2. Select a combination of ON and OFF positions for the DIP switches so that an encoding is created. This coding will be your house code, which then also ensures that all detectors / transmitters communicate with the control center.
3. Make sure the JUMPER (connection bridge) is in position below the DIP switches to remotely control the system.
4. Insert the battery under the clip and make sure that the + side faces up (visible).
Friedland SA5F — SETTING UP THE RADIO HANDHELD TRANSMITTER diagram (page 13)
Fig. 9
5. Screw the rear cover back on.
Page 14 of the Friedland SA5F user manual — POSITIONING OF THE RADIO CONTROL CENTRE
Page 14 · click to enlarge
Page 14

RADIO CONTROL CENTRE

Friedland SA5F — RADIO CONTROL CENTRE diagram (page 14)
Fig. 10

POSITIONING OF THE RADIO CONTROL CENTRE

To find the appropriate position for the central station, the following points should be considered:

1. The control center should be positioned outside the view of possible burglars in a secure location and easily accessible to the operator.
2. The center should be mounted on a flat surface to ensure that the sabotage protection of the back is closed when the center is installed. The central should be installed at a comfortable height (between 1.5 and 2m).
3. It is recommended that the central unit be positioned so that the input/output sound (sounds from the control center) can be heard outside of the monitor.
4. The control center should be positioned within a monitored zone so that any burglar cannot reach the control center without having to go through a monitord door or an area monitored by a motion detector when the system is switched sharp.
5. The central station should be mounted near a socket.
6. If you want to use the telephone dialing device, the radio control center must be connected with a phone connection.
7. The central station should be of metal objects (e.g. Mirrors, radiators etc.) must maintain a distance of at least 1m.

Exterior view of the radio control center

Page 15 of the Friedland SA5F user manual — INSTALLATION OF THE RADIO CONTROL CENTRE
Page 15 · click to enlarge
Page 15

INSTALLATION OF THE RADIO CONTROL CENTRE

Friedland SA5F — INSTALLATION OF THE RADIO CONTROL CENTRE diagram (page 15)
Fig. 11
1. Untighten the two top screws of the center and open the center. Please make sure that you do not lose the screw springs. The upper cover remains connected to the lower part.
2. On both sides, remove the rechargeable batteries (gray color) from the terminals.
3. Now hold the central station at the desired position on the wall and mark the four drill holes. Take the central station away again and drill the four 5mm holes into the wall inserting the 25mm wall dowels.
4. Turn two 18mm No.4 screws into the upper holes until the heads of the screws only look out a little bit and hang the center over these screws by pushing the screw through the guide on the top side of the case.
5. Run the connector with the power supply cable from the back through the hole in the wiring to the central control (right below the battery) and plug it into the DC socket. Make sure that the cable is not clamped between central and wall.
6. Screw the central unit tightly to the wall with two 18mm No.4 screws on the bottom side of the cover and then tighten the top two screws until they grip the case. Do not overtighten the screws, otherwise the housing could be damaged or deformed.
7. Make sure that "Reset" and the wired siren sabotage protection are in OFF position. .
8. Connect the battery cable routing to back-up batteries and refit batteries.
Battery 1 (left)Red cable to +ve battery connection

Blue cable to –ve Battery connector

Battery 2 (right)Blue cable to +ve battery connection

Black cable to –ve Battery connector

Interior view of the radio control center

Page 16 of the Friedland SA5F user manual — RADIO CONTROL CENTER AND RADIO HAND TRANSMITTER TEST
Page 16 · click to enlarge
Page 16
9. Once you have the control panel attached, remove the protective film on the LCD display.
10. Plug the power supply plug into the socket (the Power LED should be lit).
11. If desired, connect the radio control center to the telephone line by using a suitable phone adapter with an RJ11 connection and plug it into the LINE socket which is located on the bottom of the control center.

on the radio control center, in order to bring the system back into its basic position.

CONFIGURING THE HOUSE CODING OF THE RADIO CENTER

With the control center in standby mode (only the power LED lights up).

. Main user access code

‘1. ‘USER SETUP’ (User TERMINATION) appears in the display.

This puts the system into programming mode.

2. Use them

Until I get to the menu '2. ‘SYSTEM SETUP’ appears and

3. ‘2-1 Learn House Code’ appears on display. Then press

The current house code appears in the display.

4. The new house code can be programmed either directly at the control center or with the help of a radio handheld transmitter.

At the radio control centre:

Pressing buttons 1-8 of the control center allows you to set the house code. By pressing the keys 1 - 8, either "O" or "1" is established as a coding. In this way, you configure the eight-digit house code from a number combination 0 or 1, e.g. 01010101.

1 = House code DIP switch is on ON/UP

0 = House code DIP switch is OFF/DOWN

By using the radio handheld transmitterWith the already configured desired house code in radio

Hand transmitter, press the button

on the radio handheld transmitter.

When the control center receives the signal from the radio hand transmitter, a beep sounds and the display will show the changed house code below numbers 1-8.

to save the new setting or

to leave the area without storage.

to return to standby mode.

RADIO CONTROL CENTER AND RADIO HAND TRANSMITTER TEST

‘TEST MODE – WALK TEST’ (TEST-MODUS – RUN-TEST) appears on the display.

This puts the system into test mode.

2. Use the buttons

Until the ‘WALK TEST’ menu appears.

To activate the test.

‘Walk Test Waiting...’ appears on the display.

3. Press the buttons on the radio handheld transmitter alternately to see if each red
Show 9 more labels / short text on this page
, · ,· ,• , then press · . User access code
Page 17 of the Friedland SA5F user manual — POSITIONING THE PIR RADIO MOTION DETECTOR
Page 17 · click to enlarge
Page 17

LED lights up and a double beep sounds in the central station.

4. Test the range of the radio handheld transmitter by pressing the “DISARM” (UNSCHARF) button on the Radio Handheld Transmitter from inside and outside the surveillance area (house, apartment, office etc.), and anywhere where you want to position either a motion detector or magnetic contacts or the control panel. Check the respective confirmation of the radio signal when pressing the DISARM button.

to return to the test mode (“TEST MODE”). PASSIVE INFRARED (PIR) RADIO MOTION DETECTORS

PIR motion detectors are developed to detect movement in a monitored area by registering heat changes from infrared radiation planes, e.g. when a person runs into the detection area or moves in it. If movement is detected, a radio signal will be triggered (if the system and zone are switched to live).

Any number of PIR radio motion detectors can be used for the system as long as the house coding is consistent and the detector is within a range from the radio control center.

The PIR radio motion detector is powered by a 9V block battery, which under normal circumstances has a life of just over 1 year. If the battery becomes too weak, an LED display behind the lens is illuminated in normal mode and with the housing closed. If this state occurs, the battery should be renewed as quickly as possible.

POSITIONING THE PIR RADIO MOTION DETECTOR

The recommended position for a PIR radio motion detector is in the corner of a room at an altitude between 2 and 2.5m. At this height, the detector reaches a maximum range of up to 12m with a monitoring angle of 110°.

Friedland SA5F — POSITIONING THE PIR RADIO MOTION DETECTOR diagram (page 17)
Fig. 12

The position of the PCB inside the PIR can be set in 5 different positions to establish the desired monitoring range. Position 3, the range is reduced to approx. 9m, with position 1 you reach a range of approx. 6 m. Position 5 is recommended.

When planning and deciding the assembly position, for a problem-free function, the following should be taken into account:

1. Do not position the motion detector head-on to a window or direct sunlight. PIR motion detectors are not suitable for use in conservatories.
2. Do not position the motion detector in the area of airlift.
3. Do not position the detector directly via a heat source
4. If possible, mount the motion detector in the corner of a room so that an intruder’s logical pathways can be monitored. PIR motion detectors respond more accurately when crossing the surveillance levels, rather than approaching the frontal PIR.
5. Do not position the motion detector if it is exposed to strong vibration there.
Page 18 of the Friedland SA5F user manual — DIP 1 DIP 2 DIP 3
Page 18 · click to enlarge
Page 18
6. Ensure that the radio motion detector is within range of the control center (see "Radio Control Center and Radio Hand Transmitter Testing")

INSTALLATION AND CONFIGURATION OF THE PIR RADIO MOTION DETECTOR

Make sure the system is in test mode.

1. Turn out the bottom screw of the motion detector and carefully remove the housing cover.
2. Drill through the intended mounting holes, depending on whether you prefer a corner assembly or flat wall installation.
Friedland SA5F — INSTALLATION AND CONFIGURATION OF THE PIR RADIO MOTION DETECTOR diagram (page 18)
Fig. 13
3. Use the case rear wall as a template to mark the 5mm drill holes.
4. Attach the housing rear wall by turning both screws into the dowels. Do not overtighten the screws, otherwise the housing could be damaged.
5. Configure the house code in the radio motion detector by placing SW2's DIP switches 1-8 into the same ON/OFF combination as other system devices' home coding.
6. Configure the alarm zone into which to integrate the radio motion detector by setting SW3 DIP switches 1-3 as follows:

DIP 1 DIP 2 DIP 3

Zone 1 OFF OFF

Zone 2 OFF OFF ON

Zone 3 OFF ON OFF

Zone 4 OFF ON

Zone 5 ON OFF OFF

Zone 6 ON OFF ON

e.g. If you want the PIR to work in Zone 3, set the DIP switches as follows:

7. The DIP switch 4 of the SW3 serves for configuring during the WALK TEST mode, which allows to check the functionality of the motion detector during assembly without triggering a full alarm.

ON Walk Test Mode (Run-Test mode)

OFF Normal Function

Page 19 of the Friedland SA5F user manual — TEST OF THE PIR RADIO MOTION DETECTOR
Page 19 · click to enlarge
Page 19
8. The PIR motion detector contains an anti-mis alarm function to provide messages of general environmental influences (such as e.g. Insect, air temperature etc. should be excluded. This function is called the pulse count and can be selected between 1 or 2 impulse monitoring.

The 1-pulse monitoring is recommended. In the event of extreme environmental influences or unreasonable false alarms, 2-impulse monitoring may be necessary.

To set the desired pulse number, slide the DIP 5 switch on SW3 as follows:

9. Connect the 9V block battery to the battery clip
10. Make sure the monitoring PCB is set and positioned correctly to ensure the desired pattern of surveillance zone.

To easily set the PCB position, simply slide up or down the “PCB Position Indicator” (see sketch) until it comes with the desired monitoring range (see table).

Friedland SA5F — TEST OF THE PIR RADIO MOTION DETECTOR diagram (page 19)
Fig. 14
11. Reconnect the motion detector to the rear housing cover. Press the bottom side of the detector into the device and screw it back in. Do not overtighten the screw, otherwise the housing could be damaged.

TEST OF THE PIR RADIO MOTION DETECTOR

Make sure the system is in test mode.

Make sure the motion detector is set to “Walk Test Mode” (e.g., Run-Test mode). DIP 4 on the SW3 ON) and mounted to the wall.

The motion detector takes 2-3 minutes to stabilize before the test begins.

1. Go with the keys

appears through the menu up to in the ‘WALK TEST’ (LAUF-TEST) menu.

, to activate the run test.

“Walk Test Waiting...” (LAUFT-TEST WAITING...) is displayed.

2. Move into the surveillance area and walk around slowly in it. Every time the detector perceives movement, the LED lights up behind the lens. In addition, the radio control center emits a beep to signal that the alarm signal has been received and the identified zone by configuring the motion detector is displayed.

If necessary, adjust the monitoring range by changing the PCB position within the housing.

Show 6 more labels / short text on this page
ON 1 pulse monitoring · OFF 2 pulse monitoring * PCB position range · 1 6m · 3 9m · 5 12m
Page 20 of the Friedland SA5F user manual — INSTALLATION AND ADJUSTMENT OF THE RADIO MAGNETIC CONTACT
Page 20 · click to enlarge
Page 20
3. Remove the rear cover of the motion detector. The radio control center should emit beeps and "Accessory Tamper" (accessories sabotage) should appear to signal that the motion detector's sabotaging function has been activated.

to return to the menu level TEST MODE (TEST-MODUS).

5. Set the motion detector back to normal operation by setting the DIP4 switch on SW3 back to OFF.

RADIO MAGNETIC CONTACT

The magnetic radio contact consists of two parts: a detector/transmitter and a magnet. These have been specially developed for use on doors and windows. The magnet should be attached to the movable/opening part and the detector/transmitter to the fixed part (door/window frame). The fastening can be done using either the adhesive strips or screws (both are attached). Note: If the detector is mounted on a wallpaper, you should use screws.

When the door/window to be monitored is closed, the magnet and detector are positioned at a small distance from each other in the marked positions, i.e. the arrow of the magnet points at a small distance to the line of the detector/transmitter. By opening the window/door, magnet and detector/transmitter are removed from each other and thus a radio alarm signal is triggered if the alarm system and zone have been switched to sharp.

The radio magnetic contact also has a device for an additional wired contact. This additional contact must have a normal closing contact with open contacts in order to be able to trigger an alarm.

Any number of radio magnetic contacts can be used for the system as long as they are all configured with the appropriate house coding and within wireless range with the control center.

The radio magnetic contact is supplied with two CR2032 lithium button cell batteries, which under normal circumstances have a service life of approx. 1 year. In normal battery status, the detector LED will not light up when alarm is reported (except in test mode). At low battery status, the LED is set for approx. Light up for 1 second when the detector is triggered. In this case, the batteries should be renewed as soon as possible.

POSITIONING OF THE RADIO MAGNETIC CONTACT

The radio magnetic contact is suitable only for mounting at dry points in the interior.

Decide which doors and windows should be secured by radio magnetic contacts (usually, at least the front and rear doors should thus be secure). In addition, however, additional radio magnetic contacts (e.g. in the garage) to increase protection.

Ensure that the selected position for radio magnetic contact is in effective radio range to the control center (see “Test Radio Control Center and Hand Transmitter”).

INSTALLATION AND ADJUSTMENT OF THE RADIO MAGNETIC CONTACT

Make sure the system is in “Test Mode” (test mode).

1. Push back the battery cover and lift it to open the detector/transmitter (please do not use a screwdriver).
Page 21 of the Friedland SA5F user manual — RADIO MAGNETIC CONTACT
Page 21 · click to enlarge
Page 21
Friedland SA5F — RADIO MAGNETIC CONTACT diagram (page 21)
Fig. 15
2. Mount the detector/transmitter on the fixed part of window/door along the opening side by either using double-sided adhesive strips or screws (if mounted to wallpaper please screw).

If you want to screw, use the screw guide on top of the detector and pierce the screw marking at the bottom, underneath the battery holder (visible from inside). Please make sure that you do not overtighten the screws, otherwise the housing could be damaged.

3. Mount the magnet on the moving part of window/door, opposite to the detector (at the height of arrow and line marking) with screws or adhesive tape. The distance between magnet and detector should not be greater than 10 mm.
Friedland SA5F — RADIO MAGNETIC CONTACT diagram (page 21)
Fig. 16
4. If you want to use an additional wired magnetic contact, it should be wired with the detector/transmitter on the intended terminal block. The wired contact should be wired with two wires (LIYY 2x 0.5) of a maximum length of 1.5m. For this purpose, a cable lead-in (right above the battery holder) is provided on the housing and can be drilled through.

If you are using an additional wired magnetic contact with the radio detector, the jumper LInk S2 on the PCB must be removed.

5. Configure the house coding in the detector by putting DIP switches 1-8 into the same ON/OFF combination as for other devices.
Page 22 of the Friedland SA5F user manual — TESTING RADIO MAGNETIC CONTACT
Page 22 · click to enlarge
Page 22
Friedland SA5F — DIP 9 DIP 10 DIP 11 diagram (page 22)
Fig. 17
6. Configure the alarm zone in which the magnetic radio contact is to function with DIP switches 9-11 as follows:

DIP 9 DIP 10 DIP 11

Zone 1 OFF OFF

Zone 2 OFF OFF ON

Zone 3 OFF ON OFF

Zone 4 OFF ON

Zone 5 ON OFF OFF

Zone 6 ON OFF ON

Example: If the detector is to operate in zone 2, the DIP switches 9, 10, 11 must be set as follows:

Friedland SA5F — DIP 9 DIP 10 DIP 11 diagram (page 22)
Fig. 18
7. Push the two supplied button cell batteries into the battery holder so that the postive sites (+) point upwards when the detector is installed.
8. Push the battery bracket back into the detector carefully, so that the spring connections on both sides of the switchboard slide onto each other.
9. Push the cover back onto the detector.

TESTING RADIO MAGNETIC CONTACT

Make sure the system is in test mode “TEST MODE”.

1. Press the buttons

Until the “WALK TEST” menu appears.

to activate the Walk Test.

‘Walk Test Waiting...’ appears on the display.

2. Push the battery cover off of the detector.

The LED is set for approx. Light up for 1 second when the battery cover is removed and thus, the sabotage switch is activated. In addition, the radio control center will emit a two-tone beep to signal that an alarm has been received and "Accessory Tamper" (accessories sabotage) appears in the display.

3. Open the door/window to remove magnet and detector from each other.

As soon as the magnet moves away from the transmitter, the LED lights up for approx. 1 second to show that the detector

Page 23 of the Friedland SA5F user manual — DIP 9 DIP 10 DIP 11
Page 23 · click to enlarge
Page 23

was triggered. In addition, the radio center will sound a two-tone beep to show that an alarm signal has been received and the zone for which the detector was configured is displayed on the screen.

4. If external magnetic contacts are wired to the radio-magnetic contact, they report together.
5. Push the battery cover back to the detector.

to return to the test mode.

Page 24 of the Friedland SA5F user manual — EXTERNAL CONNECTIONS
Page 24 · click to enlarge
Page 24

EXTERNAL CONNECTIONS

The radio control center also makes possible the connection of wired zones (7 - 10) e.g. smoke detectors, sirens etc. or external telephone dialing device. The terminal block is located inside the radio control center.

Friedland SA5F — EXTERNAL CONNECTIONS diagram (page 24)
Fig. 19

To access the terminal block, press

This puts the system into test mode and prevents alarm triggering. Turn the two top screws out on the center and open up the front cover.

Before connecting any devices, make sure the memory jumper link P1 is on “OFF” and then remove the power plug and disconnect the support batteries/buffers.

After you connect the external devices, they restore power supply. Close the control panel again and turn back on the screws of the cover.

to leave the test mode and go back to standby mode.

, · , · User access code

Page 25 of the Friedland SA5F user manual — WALK TEST
Page 25 · click to enlarge
Page 25

SYSTEM TEST

First test

When the system is installed, it is recommended that each device be tested alternately according to their respective test instructions.

TESTING THE INSTALLED SYSTEM

The radio control center has a programmed test routine. You can of course test the system at any time, but it is generally recommended that you test it in intervals not longer than 3 months.

With the system in standby mode

This puts the system into test mode.

The system is now in test mode

Press the buttons

to select the appropriate test function or get into sub-menus.

to control through the menu and press

to leave the test mode and enter standby mode.

Friedland SA5F — TESTING THE INSTALLED SYSTEM diagram (page 25)
Fig. 20

WALK TEST

Before you start the test, please make sure that there is no movement of an area monitored by a radio motion detector and no door/window opening and that battery and case covers are correctly closed.

1. Go through the test mode until it appears in the display “WALK TEST” and press

‘Walk Test Waiting...’ appears on the display.

2. Trigger any detector of the system by either going through the area monitored with a radio motion sensor or opening window/door, which is monitored using a magnetic contact. By triggering each detector, the two-tone beep sounds in the control center to signal that a radio alarm signal has been received and the identified zone is displayed on the display.
3. Trigger a sabotage alarm by opening the devices’ enclosures. When the switches operate, the two-tone beep will sound and “Accessory Tamper” (accessories sabotage) appears in the display.
4. Alternately activate each button on the radio handheld transmitter. When each button is pressed, a two-tone beep will sound and the name will appear in the display.

(e.g., ‘REMOTE CONTROL DISARM’ = handheld radio transmitter fuzzy.

, · , · User access code

Page 26 of the Friedland SA5F user manual — TELEPHONE DIALING TEST
Page 26 · click to enlarge
Page 26

to leave the Walk Test mode (Run-Test Mode) and go into test mode.

ALARM TEST

in test mode until “ALARM TEST” appears on the display and press

to trigger the selected alarm for 5 seconds.

until the desired alarm appears in the display and press

Select “Wirefree Siren Test” to activate the external solar radio siren

(if fitted).

Select ‘Hardwired Siren Test’ to be integrated into the control centre as well as

activate an external wired siren (if wired).

Select ‘Relay Test’ to activate only the external wired siren (N.O./N.C.).

to leave the “Alarm Test” mode and go to test mode.

SOLAR SIREN SERVICE MODE FOR SOLAR OUTSIDE SIREN

A service mode function is built into the siren, which prevents the sabotage switch of the sirin from triggering an alarm when the siREN is removed from the wall to perform maintenance or battery replacement. After the batteries have been changed and the siren has been brought back into position, it must be returned to normal mode or else it will not react in case of an alarm.

in test mode until ‘Wirefree Siren Service ON/OFF’ (Radio-Sirene Service AN/OUS) is displayed.

, to put the radio siren into operation or service mode. The mode in which the Sirene bureau is located shall be indicated as follows:

Service mode: The siren will emit two short beeps and LED flashes, then after approx. 6 seconds of a longer sound/LED flash, immediately followed by two beeps/LED blinks to signal that it is in service mode.

Operating mode: After approx. A long beep/LED flash sounds for 6 seconds to signal that the siren is in normal operation mode.

to leave Sirene Service mode and return to the Test menu level mode.

TELEPHONE DIALING TEST

in Test mode until ‘VOICE DIALER TEST’ (TEST TELEFONSELECTION DEVICE) appears

2. When the phone dialer is turned on, it becomes active and follows the normal call order. It will call any unlocked number of the calling sequence, namely according to the set number of calls signals, with reproduction of main and intrusion messages.

The test call sequence can be set at the radio control center by pressing

They are stopped or even

call receivers by pressing

on the telephone control panel.

to leave the alarm test and return to menu level Test mode.

and press

Page 27 of the Friedland SA5F user manual — FACTORY SETTINGS
Page 27 · click to enlarge
Page 27

FACTORY SETTINGS

1. User Setup 1-1 Users 1-6 (User 1-6): Not programmed main user access code Master User Access Code: 1234 (main user accesscode) System settings

House Code Not programmed Alarm Time: ON (AN), 180s Wirefree Siren (Radio-Sirene): ON(AN) RF Jamming Detection: OFF (OFF) Back Light: 10s Alarm Relay: On Until Disarm (AN to unsetting) Zone Lockout: ONE (AN) Remote Phone Control ON/AN Telephone remote control: OFB (Off) Dial delay: OT (Choose detention method): Tone/DTMF dialler mode (Selection mode): Voice Dialler Zone Setup (zone setting) (applies to all zones, except otherwise specified).

Name: No Name Type (Type): Break-in Final Exit: OFF Chime (Gong): OFF (OFF) Entry Delay: Zone 1: ON (AN), 30s Zone 2-10: OFS Part Arm 1 (Partial Sharp 1): OFB(OFF). Voice Dialler Setup (Telephone dialer setting)

Phone Numbers: Not Programmed Message Play Time (Message Announcement): 70s Alarm Messages: Unprogrammed Call Routing (Call Order): All numbers off Call Confirms (CALL Acknowledgement): 1 Call Attempt Full Arm Setup (Full Alert Setting)

Exit Delay: ON (AN), 30s Entry Delay Beep input delay beep: ONE (AN) Exit delay beef: ATE Part-Arm 1 Setup (Partially sharp 1 setting)

Exit Delay (Exit delay)ON (AN), 30s Entry Delay Beep input delay beep: ON(AN) Exit Delay beep
Page 28 of the Friedland SA5F user manual — RESET FACTORY DEFAULT CONDITIONS
Page 28 · click to enlarge
Page 28

Part-Arm 2 Setup (Partially Setting)

Exit Delay: ON (AN), 30s Entry Delay Beep: ONE (AN) Exit delay beep: Time & Date (Time & date)

Time12:00:00 Date: 01/01/02 Latchkey Setup (door key setting)

Status: OFF (OUS) Selected User Setup:OFF (OFF, all users) Phone Numbers: Not programmed Answer Phone Setup (answering service setting)

StatusOFF (OFF) Greeting Message: Not programmed

RESET FACTORY DEFAULT CONDITIONS

(RESTORING FACTORY SETTINGS9)

to put the system into test mode. User access code

2. Screw the screws from the central unit and open the housing.
3. Unplug the power adapter plug on the DC Power socket
4. Remove both back-up batteries and disconnect the connection of the batter guide.
5. Place the jumper link P1 in position ON.
6. Reconnect the battery guides and put the back-up battery in position.

The radio control center will now independently restore all factory settings. The radio control center will now display ‘EEPROM RESET’ while the factory settings are stored. When the settings save is finished, ‘DISARM READY’ (UNSTARFLY) appears. The radio control center is now programmed with all factory settings.

7. Now connect the PSU adapter again to the DC power socket in the radio control center.
8. Reset the jumper link P1 to OFF position.
9. Close the cover of the central unit again and also turn the screws back in.

, · ,

Page 29 of the Friedland SA5F user manual — 1-1 USER (USER) 1-6
Page 29 · click to enlarge
Page 29

PROGRAMMING

first menu level and the respective sub-menus. Throughout

You get into the respective function and with a

in the respective submenus. Then again, the previous ones. Getting to higher menu level

The system is in standby mode.

Master User Access Code (main user access code)

The system is now in programming mode

Use the buttons

, in order to provide the displayed programming function or Select the submenu.

to get through the programming menu. Press

to leave programming mode and return to standby.

1. USER SETUP (USER SETTINGS)

Friedland SA5F — 1. USER SETUP (USER SETTINGS) diagram (page 29)
Fig. 21

Press the buttons

, to the first menu level on the menu item “1”. USER SETUP (1.)

User Adjustments) and then press

, to the USER 1-6 (user 1-6) as well as

MASTER-USER (main user) to program. They will find it by restoring the keys.

Press.

back to the higher menu level.

1-1 USER (USER) 1-6

Workplace setting: not programmed.

Press the buttons

to show the desired user (user) in the display and

, to program the user access code. ‘1 Access Code’

appears in the display. Press on

and in the display appears "Enter Access Code". Now enter a 4-digit code that identifies the respective user (e.g. 4711) and confirm with

. If you want to change it, press them.

, then enter another code and

Show 5 more labels / short text on this page
further · , · ; then on - confirm again with
Page 30 of the Friedland SA5F user manual — 2. SYSTEM SETTINGS (SYSTEM SETUP)
Page 30 · click to enlarge
Page 30

Record User Message (recording user message)

This allows each user to record a short (4 seconds) message, which can be used in the latch key function (door key), e.g. System of USER-1 fuzzed.

Until the menu ‘:2 Record User Message’ appears.

To record a new message, press

, to start the voice recording (max. Duration: 4s. After recording the voice, the device repeats the message

to leave the level without change.

Replay User Message (Replay of the user message)

until the menu ‘:3 Replay User Message’ appears.

to repeat the message.

, to get to the menu level user setup (user setting).

1-7 MASTER USER (MAIN USER)

Workplace setting1234

UP TO THE ‘1-7 MASTER USER SETUP’ MENU (1-7 MAIN USER SETTING)

Then it is displayed and presses.

‘1 Access Code’ (1 access code) and the current setting is displayed.

Enter a new 4-digit user code and then press

to save and leave the menu level, or

to leave the menu level without storage.

, to get to the higher level menu “User Setup” (user setting).

2. SYSTEM SETTINGS (SYSTEM SETUP)

or

Page 31 of the Friedland SA5F user manual — 2-2 ALARM DURATION
Page 31 · click to enlarge
Page 31
Friedland SA5F — Part-Arm 2 Setup (Partially Setting) diagram (page 31)
Fig. 22 · Part-Arm 2 Setup (Partially Setting)

on the first menu level up to ‘2. SYSTEM SETUP’ (2. SYSTEM-

Settings) is displayed and then press

to return to the first menu level.

2-1 LEARN SYSTEM HOUSE CODE

until the menu ‘2-1 Learn House Code’ (2-1 Learning System-House Code) appears.

The current house code is displayed. A new house code can be programmed either directly on the radio control center or with the help of the handheld radio transmitter.

At the radio control centre:

Press buttons 1-8 on the radio control center to program the desired house code. Each time buttons 1-8 are pressed, the setting is converted from “0” to “1”, or from “1” to ‘0’ so that an 8-digit house code results from a combination of “0“ and “1”.

1 = House Code DIP Switch On/Up

0 = House Code DIP Switch Off/Down

With the help of a handheld radio transmitter:

Set the DIP switches of the radio station to the desired house code and press

on the radio handheld transmitter.

When the radio control center receives the signal from the hand-held radio transmitter, then the central station emits a beep as an acknowledgement of receipt and the house code changes according to the setting of the DIP switches of the handheld radio receiver.

to save the new setting, or

, to leave the menu level without storage.

2-2 ALARM DURATION

until the menu ‘2-2 ALARM TIME’ (2-2 alarm time) appears. The current setting is also displayed.

2-2-1 On/Off status

Workplace settingON (AN)

Then the key

Page 32 of the Friedland SA5F user manual — 2-5 CONTROL PANEL BACK LIGHT
Page 32 · click to enlarge
Page 32

until the menu ‘2-2-1 Status’ appears. The current setting also appears.

to activate the siren, or

to take the siren off.

2-2-2 Alarm Duration

Workplace setting180s

until the menu ‘2-1-2 Time’ (2-1-2 time) appears.

Enter the desired alarm duration in 10s units, e.g. Enter 6 for an alarm duration of 60s (max.) Setting: 60, i.e. 600s/10min.

to save and leave the menu level, or

to leave the menu level without saving.

, to get to the first menu level.

2-3 WIREFREE SOLAR SIREN (FUNK-SOLAR-SIRENE)

Workplace settingON (AN)

until the menu ‘2-3 Wirefree Siren’ (2-3 radio siren) appears. The current setting is also displayed.

, to turn on the radio siren; or

to turn off the radio siren.

2-4 JAMMING DETECTION (RADIO EARLY DETECTION)

This function recognizes radio interference signals of the Radio Center at an early stage. If this function is activated, radio signals are continuously monitored on the operating frequency in order to avoid interference of the central station. If a disturbance signal is present, an alarm is triggered.

Workplace settingOFF (AUS)

until the menu ‘2-4 RF Jamming Detection’ appears (‘2-4 Radio Interference Protection’). The current setting is also displayed.

to turn on jammaning detection (radio interference protection), or

, to turn off the function.

2-5 CONTROL PANEL BACK LIGHT

This controls the duration of backlighting on the radio center, which is active after pressing the last button.

Workplace setting10s

until the menu ‘2-5 Back Light’ (2-5 lighting) appears. The current setting is also displayed.

until the desired duration is displayed (10, 20, 30 and 60s).

to save and leave the menu level, or

to leave the menu level without saving.

Page 33 of the Friedland SA5F user manual — 2-10 DIALLER DELAY (DIALING DELAY)
Page 33 · click to enlarge
Page 33

2-6 ALARM RELAY (ALARM RELAY)

This setting controls the duration of activation of NO/NC hardwired devices in case of alarm

If ON Until Disarm is set, the relay will be activated until the system becomes unset.

until the menu ‘2-6 Alarm Relay’ appears. The current setting is also displayed.

until the desired duration is displayed (2s, 30s, 60s, 180s, 300s and ‘ON Until Disarm’), and

to save and leave the menu level, or

to leave the menu level without saving.

2-7 ZONE LOCKOUT (ZONE EXCLUSION)

This function, if activated, can exclude individual zones from alarming more than three times before the system is switched out of focus. If the function is not activated, there is no limit when triggering an alarm for a zone.

Workplace settingON (AN)

until the menu ‘2-7 Zone Lockout’ appears (“2-7 zone exclusion”). The current setting is also displayed.

Activate Zone Lockout (zone exclusion), or

, to turn off Zone Lockout (Zone Exclusion).

2-8 REMOTE SYSTEM CONTROL (TELEPHONE REMOTE CONTROL)

With this function, if activated, the system can be remotely controlled on the go via telephone.

Workplace settingON (AN)

until it appears in the menu ‘2-8 Remote Phone Control’. The current setting is also displayed.

Activate remote phone control (telephone remote control), or

to turn off Remote Phone Control.

2-9 RINGS TO ANSWER PHONE (NUMBER OF CALL SIGNALS)

This determines the number of incoming call signals that a connected telephone receives before the answering machine and/or remote control access is switched on.

Workplace setting6

Enter the desired number of call signals (1-30) before the radio center accepts the call.

to save and leave the menu level, or

to leave the menu level without saving.

2-10 DIALLER DELAY (DIALING DELAY)

This function, if activated, delays the action of the telephone dialing device by 30 seconds so that in case of an alarm the system can still be switched out of focus and no call is made.

Workplace settingON (AN)

until the menu ‘2-10 Dial Delay’ appears. The current setting is also displayed.

Page 34 of the Friedland SA5F user manual — 2-12 DIAL MODE (SELECTION MODE)
Page 34 · click to enlarge
Page 34

to turn on "Dialler Delay", or

to turn off "Dialler Delay".

2-11 DIAL METHOD (CHOICE METHOD)

This function can be used to set the dial method with which the telephone dialing device is dialed/connected.

Workplace settingClay/DTMF

until the menu ‘2-11 Dial Method’ appears. The current setting is also displayed.

through the possible options (Tone/DTMF and Pulse) until the desired setting appears in the display,

to save and leave the menu level, or go with

to leave the menu level without saving.

2-12 DIAL MODE (SELECTION MODE)

Workplace settingVoice Dialler

until the menu ‘2-12 Dialer mode’ (selection mode) appears. The current setting is also displayed.

through the possible options (Voice Dialler and Remote Manager) until the desired setting appears in the display.

to save and leave the menu level, or

, to leave the menu level without saving.

Go with them

Page 35 of the Friedland SA5F user manual — 3-2 TYPE (ALARM TYPES)
Page 35 · click to enlarge
Page 35

3. ZONE SETUP (ZONE SETTING)

Friedland SA5F — 3. ZONE SETUP (ZONE SETTING) diagram (page 35)
Fig. 23

until the menu ‘3. ‘ZONE SETUP’ (ZONS-CESSING) appears and presses

Go to the zone number that you want configured and press

The following configuration options are available for Zone 1. The options for all other zones (2-10) are identical, except that the jurisdiction number of the zone changes according to the zone to be set.

to get to the first menu level.

3-1 NAME

Workplace setting‘No Name’ (“Not a name”)

until the menu ‘3-1 Z01 Name’ (Z01 name) appears. The current setting is also displayed.

through the possible options until the desired setting is displayed.

to save and leave the menu level, or

, to leave the menu level without saving.

3-2 TYPE (ALARM TYPES)

Each alarm zone can be programmed according to one of the five modes mentioned below, depending on which type of alarm is triggered. The following types are possible:

24-hour monitoring to trigger alarm in case of a “Personal Attack” (PA). The act shall:

Go with · Panic/PA (Panic/PA)

Page 36 of the Friedland SA5F user manual — 3-5 ENTRY DELAY
Page 36 · click to enlarge
Page 36

A PA switch immediately triggers a full alarm.

Provides standard intrusion monitoring with normal sharp/partial sharp functions.

24 Hour Intruder (24 hours burglary)

provides 24-hour monitoring for areas that need to be constantly monitored, even if the system is fuzzy (e.g. A gun cabinet. If a detector of this zone is activated, it immediately triggers a full alarm.

Provides 24-hour monitoring by fire/smoke detectors that can be integrated into the system. If a detector triggers, then immediately a full alarm is triggered.

If the system is set to high alert, each triggered detector in the zone will cause an entry into the event log without alarming.

Workplace setting‘Intruder’ (break-in)

until the menu ‘3-2 Z01 Type’ (Z01 type) appears. The current setting is also displayed.

through the possible options until the desired setting is displayed.

to save and leave the menu level, or

, to leave the menu level without saving.

3-3 FINAL EXIT SET (LAST OUTPUT SETTING)

If turned on, each triggered detector of the zone will clear the further delay time during the initial delay and turn the system to be active 5 seconds later.

Workplace settingOFF (AUS)

until the menu ‘3-3 Z01 Final Exit Set’ appears (Z01 Start setting). The current setting is also displayed.

, to switch on the initial setting of the zone; or

, to turn off the initial setting of the zone.

3-4 CHIME (GONG)

This checks whether the zone’s gong function is available.

Workplace settingOFF (AUS)

until the menu ‘3-4 Z01 Chime’ (Z01 Gong) appears. The current setting is also displayed.

, to turn on the zone's gong function; or

to turn off the zone's gong function.

3-5 ENTRY DELAY

until the menu ‘3-5 ENTRY DELAY’ appears. The current setting is also displayed.

Show 4 more labels / short text on this page
Intruder (break-in) · Fire (Fire) · Test (test) · Go with
Page 37 of the Friedland SA5F user manual — 3-8 WALK THROUG (PASSAGE)
Page 37 · click to enlarge
Page 37

On/Off Status (On/off damming)

Workplace settingZone 1: ON (AN), zones 2-10: OFF

until the menu ‘3-5-1 Status’ appears. The current setting is also displayed.

, to switch on the zone access delay; or

, to turn off the zone access delay.

Workplace setting30s

until the menu ‘3-5-2 Delay Time’ appears.

Enter the desired delay time (10 to 250s).

to save and leave the menu level, or

, to leave the menu level without saving.

to return to the first menu level.

3-6 PART-ARM 1 (PARTIALLY ACTIVE CIRCUIT 1)

This sets the zones that are active in partial sharp circuit 1 when partial sharp gate 1 has been turned on.

Workplace settingOFF (AUS)

until the menu ‘3-6 Z01 Part-Arm 1’ (Z01 part sharpness 1) appears. The current setting is also displayed.

, to switch on the zone in partial sharp circuit 1, or

, to switch off the zone in partial sharp circuit 1,

3-7 PART-ARM 2 (PARTIALLY ACTIVE CIRCUIT 2)

This sets the zones that are active in partial sharp circuit 2 when partial sharp gate 2 has been turned on.

Workplace settingOFF (AUS)

until the menu ‘3-7 Z01 Part-Arm 2’ (Z01 part sharp 2) appears. The current setting is also displayed.

, to switch on the zone in partial sharp circuit 2, or

, to switch off the zone in partial sharp circuit 2 .

3-8 WALK THROUG (PASSAGE)

Workplace settingOFF (AUS)

until the menu ‘3-8 Z01 Wlk Thru’ (Z01 DURCHGANG) appears. The current setting is also displayed.

through the possible options (Off, Entry-Door and Entry route) (OFF, Access Door, Access Route), until the desired setting is displayed.

to save and leave the menu level, or

Delay period (delay time) · Go with

Page 38 of the Friedland SA5F user manual — 4-1 TELEPHONE NUMBERS (TELEPHONE NUMBERS)
Page 38 · click to enlarge
Page 38

, to leave the menu level without saving.

4. VOICE DIALER SETUP (SETTING PHONE DIALING DEVICE)

Friedland SA5F — 4. VOICE DIALER SETUP (SETTING PHONE DIALING DEVICE) diagram (page 38)
Fig. 24

until the menu '4. ‘VOICE DIALER SETUP’ (TELEFONSELECTOR) appears and presses

to return to the first menu level.

4-1 TELEPHONE NUMBERS (TELEPHONE NUMBERS)

until the menu ‘4-1 PHONE NUMBERS’ appears and press

until the desired telephone number (1-4) appears in the menu. The current setting of each phone number is also displayed.

To change the numbers, press

Enter the new phone number (32 numbers max)

to save and leave the menu level, or

, to leave the menu level without saving.

, to enter a 3.5s break in the dial sequence.

Move the cursor to the left.

Move the curor to the right.

to delete the characters under the cursor.

Press and hold them

to delete the whole phone number.

After you have programmed all the phone numbers that you want, press

to return to the first menu level.

Size

Page 39 of the Friedland SA5F user manual — 4-5 CALL ROUTING (CALL ORDER)
Page 39 · click to enlarge
Page 39

4-2 ALARM MESSAGE PLAY TIME (ALERT MESSAGE TIME)

This means the entire time in which the alarm message is played and repeated when a call executed by telephone dialing device is accepted.

Workplace setting70s

until the menu ‘4-2 Message Play Time’ appears. The current setting is also displayed.

through the possible options (50, 70, 90 and 110s) until the desired setting is displayed.

to save and leave the menu level, or

, to leave the menu level without saving.

4-3 RECORD ALARM MESSAGES

until the menu ‘4-3 RECORD VOICE’ appears and press

through the possible options until the desired message type is displayed, which should be recorded.

a) Main alarm message, (12 seconds max. 12s

b) Intruder alarm message, (4 seconds max). 4s

c) Fire alarm message, (4 seconds max). 4s

d) Panic/PA alarm message, (4 seconds max). 4s.

To record a new message, press

to start recording the voice message. When you have finished recording, the voice message is automatically repeated; or

to leave the menu level without change.

, to stop the recording and delete the remaining recording time.

to return to the first menu level of the telephone dialing device. .

4-4 REPLAY ALARM MESSAGES (REPEAT ALERT MESSAGES)

UNTIL IN THE MENU ‘4-4 REPLAY ALARM MESSAGES’ (REPEAT ALERT MESSAGES)

Appears and presses

through the possible options until the desired message type is displayed.

a) Main + Intruder Messages (main and burglary messages)

b) Main + Fire Messages (main and fire messages)

c) Main + Panic/PA Messages (main and panic/Pac messages)

To repeat the message, press

to return to the first menu level in the telephone dialing device.

4-5 CALL ROUTING (CALL ORDER)

This function controls which phone numbers should be called if the telephone dialing device is activated.

The order of the stored telephone numbers is displayed with the digits 1-4. An “X” means the number is

Go with · Walk with · Go with

Page 40 of the Friedland SA5F user manual — 5. FULL ARM SETUP (FULL ALARM SET)
Page 40 · click to enlarge
Page 40

Not unlocked and an “O” means the number is unlock. If e.g. the “OOOX” is displayed, numbers 1-3 are called in sequence and number 4 cannot be called.

Workplace setting: All numbers disabled.

until the menu ‘4-5 CALL ROUTING’ appears. The current setting is also displayed.

by the possible options until the desired phone numbers (1-4) that are to be configured appear. The current setting is also displayed.

to turn on the number in order, or

, to turn off the number in order.

, to get to the “Voice Dialler Setup” menu level.

4-6 TEL CONFIRM TIMES (CALL RECEIPT ACKNOWLEDGEMENT)

This sets the number of phone numbers to be confirmed that stop the telephone dialing device. If you e.g. “2” is set, the call order will continue to run until a call acknowledgement has been received from 2 different numbers (e.g. by telephone numbers 1 and 3.

Workplace setting1

until the menu ‘4-6 Tel Confirm Times’ appears. The current setting is also displayed.

To change the settings, press

Enter the desired number (1-4).

to save and leave the menu level, or

, to leave the menu level without saving.

4-7 CALL ATTEMPTS

This sets the maximum number of call attempts that the dialer dials in the call order.

Workplace setting3

until the menu ‘4-7 Call Attempts’ appears. The current setting is also displayed.

Enter the desired number (1-5).

to save and leave the menu level, or

, to leave the menu level without saving.

5. FULL ARM SETUP (FULL ALARM SET)

Go with them

Page 41 of the Friedland SA5F user manual — 5-1 EXIT DELAY
Page 41 · click to enlarge
Page 41
Friedland SA5F — Part-Arm 2 Setup (Partially Setting) diagram (page 41)
Fig. 25 · Part-Arm 2 Setup (Partially Setting)

up to the menu ‘5. ‘FULL ARM SETUP’ (SET FULL ALARM) Appears and presses

, to get back to the first menu level.

5-1 EXIT DELAY

up to the menu ‘5-1 EXIT-DELAY’ appears. The current setting is also displayed.

On/Off status (on/off status)

Workplace settingON (AN)

up to the menu ‘5-1-1 Status’ appears. The current setting is also displayed.

, to switch on the output delay; or

, to switch off the output delay.

Workplace setting30s

up to the menu ‘5-1-2 Delay Time’ appears. The current setting is also displayed.

Enter the desired delay time (10 to 250s).

to save and leave the menu level, or

, to leave the menu level without saving.

to return to the “Full Arm Setup” menu level.

5-2 ENTRY DELAY BEEP (input delay signal)

This is to control the warning sound (beep) that will be heard during input delay time when a full alarm is active.

Workplace settingON (AN)

until the ‘5-2 Entry Delay Beep’ (input delay signal) appears in the menu. The current setting is also displayed.

, to turn on the input delay signal; or

You · Delay period (delay time)

Page 42 of the Friedland SA5F user manual — 6-1 EXIT DELAY
Page 42 · click to enlarge
Page 42

, to switch off the input delay signal.

5-3 EXIT DELAY BEEP (OUTPUT DELAY SIGNAL)

This is to control the warning sound (beep) that will be heard during initial delay time when a full alarm is active.

Workplace settingON (AN)

until the ‘5-3 Exit Delay Beep’ menu appears. The current setting is also displayed.

, to turn on the output delay signal; or

, to switch off the output delay signal.

6. PART-ARM 1 SETUP (SETTING PARTIAL ALARM 1)

Friedland SA5F — 6. PART-ARM 1 SETUP (SETTING PARTIAL ALARM 1) diagram (page 42)
Fig. 26

until the menu '6. PART-ARM 1 SETUP’ (STAKE THE PART ALARM) appears and presses

to return to the first menu level.

6-1 EXIT DELAY

up to the menu ‘6-1 EXIT-DELAY’ appears. The current setting is also displayed.

On/Off status (on/off status)

Workplace settingON (AN)

up to the menu ‘6-1-1 Status’ appears. The current setting is also displayed.

, to switch on the output delay; or

, to switch off the output delay.

Workplace setting30s

up to the menu ‘6-1-2 Delay Time’ appears. The current setting is also displayed.

Enter the desired delay time (10 to 250s).

You · Delay period (delay time)

Page 43 of the Friedland SA5F user manual — 7-1 EXIT DELAY
Page 43 · click to enlarge
Page 43

to save and leave the menu level, or

, to leave the menu level without saving.

to return to the “Full Arm Setup” menu level.

6-2 ENTRY DELAY BEEP (input delay signal)

This is to control the warning sound (beep) that will be heard during input delay time when a full alarm is active.

Workplace settingON (AN)

until the menu ‘6-2 Entry Delay Beep’ appears. The current setting is also displayed.

, to turn on the input delay signal; or

, to switch off the input delay signal.

6-3 EXIT DELAY BEEP (OUTPUT DELAY SIGNAL)

This is to control the warning sound (beep) that will be heard during initial delay time when a full alarm is active.

Workplace settingON (AN)

until the ‘6-3 Exit Delay Beep’ menu appears. The current setting is also displayed.

, to turn on the output delay signal; or

, to switch off the output delay signal.

7. PART-ARM 2 SETUP (SETTING PART-ALARM 2)

Friedland SA5F — 7. PART-ARM 2 SETUP (SETTING PART-ALARM 2) diagram (page 43)
Fig. 27

until the menu '7. PART-ARM 1 SETUP’ (STAKE THE PART ALARM) appears and presses

to return to the first menu level.

7-1 EXIT DELAY

up to the menu ‘7-1 EXIT-DELAY’ appears. The current setting is also displayed.

On/Off status (on/off status)

Size

Page 44 of the Friedland SA5F user manual — 8. TIME AND DATE SETUP
Page 44 · click to enlarge
Page 44
Workplace settingON (AN)

up to the menu ‘7-1-1 Status’ appears. The current setting is also displayed.

, to switch on the output delay; or

, to switch off the output delay.

Workplace setting30s

up to the menu 7-1-2 Delay Time appears. The current setting is also displayed.

Enter the desired delay time (10 to 250s).

to save and leave the menu level, or

, to leave the menu level without saving.

to return to the “Full Arm Setup” menu level.

7-2 ENTRY DELAY BEEP (input delay signal)

This is to control the warning sound (beep) that will be heard during input delay time when a full alarm is active.

Workplace settingON (AN)

until the ‘7-2 Entry Delay Beep’ (input delay signal) appears in the menu. The current setting is also displayed.

, to turn on the input delay signal; or

, to switch off the input delay signal.

7-3 EXIT DELAY BEEP (OUTPUT DELAY SIGNAL)

This is to control the warning sound (beep) that will be heard during initial delay time when a full alarm is active.

Workplace settingON (AN)

until the ‘7-3 Exit Delay Beep’ menu appears. The current setting is also displayed.

, to turn on the output delay signal; or

, to switch off the output delay signal.

8. TIME AND DATE SETUP

Delay period (delay time)

Page 45 of the Friedland SA5F user manual — 9. LATCH KEY SETUP (Digital House Key Function)
Page 45 · click to enlarge
Page 45
Friedland SA5F — Part-Arm 2 Setup (Partially Setting) diagram (page 45)
Fig. 28 · Part-Arm 2 Setup (Partially Setting)

until the menu ‘8 TIME & DATE SETUP’ appears and presses

to return to the first menu level.

8-1 DATE (DATE)

until the menu ‘8-1 Date’ appears. The current setting is also displayed.

Enter the date in the format ‘DD/MM/YY’.

to save and leave the menu level, or

, to leave the menu level without saving.

8-2 TIME (ZEIT)

until the menu ‘8-2 Time’ appears. The current setting is also displayed.

Enter the date in the following format: ‘HH/MM/SS’.

to save and leave the menu level, or

, to leave the menu level without saving.

9. LATCH KEY SETUP (Digital House Key Function)

Size

Page 46 of the Friedland SA5F user manual — 9-2 SELECTED-USERS SETUP (SET SELECT USERS)
Page 46 · click to enlarge
Page 46
Friedland SA5F — Part-Arm 2 Setup (Partially Setting) diagram (page 46)
Fig. 29 · Part-Arm 2 Setup (Partially Setting)

until the menu '9. LATCH KEY SETUP’ (HOUSEKLE ASSESS) appears and

to return to the first menu level.

9-1 STATUS

This sets the users who use the front door key. If you set Selected Users, the front door key will only work for those users selected in the 9-2 Selected user Setup menu.

Workplace settingOFF (AUS)

until the menu ‘9-1 Status’ appears. The current setting is also displayed.

through the possible options (Off, Selected-Users and All-Uzers) until the desired setting appears.

to save and leave the menu level, or

, to leave the menu level without saving.

9-2 SELECTED-USERS SETUP (SET SELECT USERS)

This gives you control over the users for whom the front door key has been selected.

Workplace settingOFF (AUS)

UNTIL IN THE MENU ‘9-2 SELECTED USER SETUP’

Appears and presses

through the menu until the desired user number (1-6) that is to be set appears in the display. The current setting is also displayed.

to turn on the front door key for the user, or

Go with · go with

Page 47 of the Friedland SA5F user manual — 10-1 ON/OFF STATUS
Page 47 · click to enlarge
Page 47

to turn off the front door key for the user.

After you have set all users as desired, press SIe

to return to the “Latch Key Setup” menu level.

9-3 TELEPHONE NUMBERS (TELEPHONE NUMBERS)

until the menu ‘9-3 PHONE NUMBERS’ appears and press

through the menu until the desired telephone number (1-2) appears. The current setting is also displayed.

Enter the new phone number (max). 32 digits.

to save and leave the menu level, or

, to leave the menu level without saving.

, to build in a 3.5s break during the dial process.

to move the cursor to the left.

to move the cursor to the right.

to delete the character under the cursor.

to delete the complete phone number.

After you have programmed the desired phone numbers, press

to return to the “Latch Key Setup” menu level.

10. ANSWER PHONE SETUP (SETTING ANSWERING MACHINE)

Friedland SA5F — 10. ANSWER PHONE SETUP (SETTING ANSWERING MACHINE) diagram (page 47)
Fig. 30

until the menu ‘11. ‘ANSWER PHONE SETUP’ (SETTING ANSWERING MACHINE)

Appears and presses

to return to the first menu level.

10-1 ON/OFF STATUS

Workplace settingOFF (AUS)

until it appears in the menu "11-1 Status". The current setting is also displayed.

to turn the answering machine on, or

Go with them

Page 48 of the Friedland SA5F user manual — 11-1 TELEPHONE NUMBER (PHONE NUMBER):
Page 48 · click to enlarge
Page 48

to turn off the answering machine.

10-2 RECORD GREETING (RECORDING GREETING)

until the menu ‘11-2 Record Greeting’ appears.

To receive the new welcome, press

, to start the voice recording (max. Duration:12s. When you have finished speaking, the announcement is automatically repeated or

to leave the menu level without change.

, to stop the recording and delete the remaining time.

10-3 REPLAY GREETING

until the menu ‘11-3 Replay Greeting’ appears.

To repeat the greeting, press

11. REMOTE MANAGER SETUP (setting only for guard duty)

Friedland SA5F — 11. REMOTE MANAGER SETUP (setting only for guard duty) diagram (page 48)
Fig. 31 · 11. REMOTE MANAGER SETUP (setting only for guard dut…

until the menu ‘12. ‘REMOTE MANAGER SETUP’ (SET REMOTE CONTROL)

Appears and presses

to return to the first menu level.

11-1 TELEPHONE NUMBER (PHONE NUMBER):

until the menu ‘12-1 Phone No:’ (phone number) appears. The acous setting is also displayed.

Enter the new phone number (max). 32 digits.

to save and leave the menu level, or

, to leave the menu level without saving.

, to build a 3.5s break in the dial sequence.

to move the cursor to the left.

to move the cursor to the right.

to delete the character under the cursor.

to delete the complete phone number.

Page 49 of the Friedland SA5F user manual — CALL ATTEMPTS (CALL ATTEMPTS)
Page 49 · click to enlarge
Page 49

11-2 UNIT ID

until the menu ‘12-2 Unit ID No:’ appears. The current setting is also displayed.

Enter the system code (max). 4 digits) which you receive from the service company. (Please do not confuse this with the system house code).

To enter the ID code "B", press

To enter the ID code “C”, press

To enter the ID code “D”, press

To enter the ID code “E”, press

To enter the ID code “F”, press

to save and leave the menu level, or

, to leave the menu level without saving.

CALL ATTEMPTS (CALL ATTEMPTS)

This sets the maximum number with which the dialer tries to contact each phone number of call order that is switched on.

Workplace setting3

until the menu ‘12-3 Call Attempts’ appears. The current setting is also displayed.

Enter the desired number (1-5).

to save and leave the menu level, or

, to leave the menu level without saving.

Show 5 more labels / short text on this page
, · , · , · , · ,
Page 50 of the Friedland SA5F user manual — GENERAL (BASIC)
Page 50 · click to enlarge
Page 50

INSTRUCTIONS FOR USE

SHORT INSTRUCTIONS

Control Panel Remote Control

Part arm 1 (partial sharpness 1)

Part arm 2 (partial sharpness 2)

Chime On/Off (Gong on/off)

Keypad Beep Mute On/Off

PA (personal). Attack

(hold for 3s) slide PA switch up

LED Indicators:

Off (Off) Flashing (Blinking Lights) On (On)

POWER No power Battery powered Mains Powered

Operation Off-Operation Battery operated socket operation

LOW BAT Detector batteries OK PIR detector battery low MAG detector battery

Low battery battery OK battery motion detector low battery magnetcont. Low

GENERAL (BASIC)

When buildings are abandoned, the system should be switched to sharpness. Before doing this, check that all windows and doors are closed and that the motion detectors are not blocked. Make sure pets can only be in areas that are not protected by a motion detector.

The system can be set in three alarm positions: sharp, partially sharp 1, partly sharp 2. The partial sharpness setting allows you to leave selected areas out of focus while the remaining parts of the system are set.

If the system is switched to a state of readiness (no matter in which alarm position), the radio control center will display the alarm position and the status of the front door key for several seconds. If turned on, the “countdown” of the initial delay time is displayed. As soon as the output delay time expires, a beep sounds from the central station with an increasing clock number, the further the time elapses. At the end of the initial delay time, the system is then switched to a live state. At this time, the user must have left the building and closed the exit door.

If a detector of an active zone is triggered in the case of a system with a sharp switch, if it is turned on, the programmed initial delay time for this zone will start a “countdown” and display it on the display. If the access delay time expires, a beep sounds from the central station as the clock number increases, the further the time elapses. If the system is not switched to be unsharp until the expiry of the access delay time, an alarm will be triggered. If the access delay of an activated zone is not switched on, without

Show 23 more labels / short text on this page
Arm (Sharp) ·, ·, , · ,·, · ·,•, · - Disarm (Unsharp), ·, × Record Voice Memo · (Recording voice message) · Listen to messages · (Listening messages) · .
Page 51 of the Friedland SA5F user manual — DISARMING THE SYSTEM (SWITCHING OUT OF FOCUS)
Page 51 · click to enlarge
Page 51

Delay, immediately triggered alarm.

Upon expiration of the programmed alarm period, the internal siren of the radio control center will cease and the system is automatically switched back to live.

In the event of a triggered alarm and an activated telephone dialing device, the first unlocked call number in the call sequence is called up and the recorded voice message is received according to the entered “Play Time”

(playback time) repeated. The call receiver should receive the message by pressing the button

on the phone to stop another activity of the dialing device. If no acknowledgement of receipt is made, the next number of the programmed call sequence will be called. The telephone dialer will continuously call any unlocked number until either all numbers in the calling sequence have been called (according to the programmed ring count) or until a receiver has confirmed the message.

ARMING THE SYSTEM (SWITCH SYSTEM SHARP)

POOR (SHARP)

The system can be set to the tune either by means of a handheld radio transmitter or at the control center as follows:

Remote control (radio handheld transmitter):

The radio control center will emit a received signal in the form of a beepton.

Control Panel (Radio Center):

PART-ARMING THE SYSTEM (PART-ARM 1) (SWITCHING IT IN A PARTIALLY SHARP MANNER – PART-SHARP 1)

The system can be switched either with the aid of a radio handheld transmitter or at the radio control center as follows:

Remote control (radio handheld transmitter):

Press the “Partially Specified” button

The radio control center will emit a received signal in the form of a beepton.

Control Panel (Radio Center):

PART-ARMING THE SYSTEM (PART-ARM 2) (SEMI-SETTING – SUB-SET)

The system can be switched either with the aid of a radio handheld transmitter or at the radio control center as follows:

Remote control (radio center):

Press the “Partially Specified” button

The radio control center will emit a received signal in the form of a beepton.

Control Panel (Radio Center):

DISARMING THE SYSTEM (SWITCHING OUT OF FOCUS)

The system can be switched out of focus either with the aid of a handheld radio transmitter or at the control center as follows:

Remote control (radio handheld transmitter):

Show 10 more labels / short text on this page
Voice Dialler (phone dialing device) · , · , · User access code · , · , · User access code · , · , · User access code
Page 52 of the Friedland SA5F user manual — CHIME (GONG)
Page 52 · click to enlarge
Page 52

The radio center will emit a received signal in the form of a beepton.

Control Panel (Radio Center):

If the system is switched to a fuzzy state and the LED light ‘ALARM MEM’ (alarm indication) glows with simultaneous beep of the control center at a distance of 10 s, it shows you that an alarm has been triggered.

, to turn off the lighting of the LED and beep.

QUICK SET (QUICK SETTING)

To use the Quick setting and set the plant to 5s, skip remaining initial delay time as follows:

First, bring the plant to the desired mode (i.e. Full Arm, Part-Arm 1 or Part-arm2 (Full alarm, part alert)

1 or partial alarm 2), as described above and then press

OMIT ZONE (ZONE OF INJUNCTION)

To cut out a zone from the next alarm,

until the desired zone appears in the menu. The current setting is also displayed.

to leave the zone (i.e. zone omit ON) (e.g. Zone recess AN.

to activate the zone again (i.e. zone omit OFF) (e.g. Zones of the exclusion.

After you have completed the setting for the desired zone recess, press

Return to standby mode.

PERSONAL ATTACK (PA) ALARM (PANIC / PA ALARM)

A full alarm can be triggered immediately in any mode (whether the system is switched sharp or out of focus) in case of a personal threat or danger, either by the switch on the radio handheld transmitter or the radio control center.

Remote control (radio handheld transmitter):

Push the PA switch up.

Control Panel (Radio Center):

and hold the button for approx. 3 seconds pressed.

The alarm will sound until the set alarm duration has elapsed or the system is switched out of focus again.

TAMPER (SABOTAGE/MANIPULATION)

If the battery cover of a device is opened or the radio control center is removed from the wall, a full alarm will be triggered immediately even if the system has been switched out of focus. The alarm signal will either sound according to the set alarm duration or until the system is switched off again. The LED light ‘ALARM MEM’ (alarm warning) on the radio control center will illuminate and the control center emits beeps to indicate that an alarm has been triggered.

CHIME (GONG)

The Gong function can only be used in standby mode.

Show 6 more labels / short text on this page
, · , · User access code · , · , · User access code
Page 53 of the Friedland SA5F user manual — REMOTE SYSTEM CONTROL (ON-THE-GO PHONE REMOTE CONTROL)
Page 53 · click to enlarge
Page 53

, to switch back and forth between ON/OFF (ON/Off).

EVENT LOG (EVENT PROTOCOL)

The event protocol detects and stores the last 50 events (setting, unsettling circuits, alarm and detector battery weaknesses). The log records the time, date and details of Jade’s event. If, while the system is fuzzy, the LED “ALARM MEM” lights up and the control center beeps every 10 s, this means that an alarm has been triggered. To stop the LED and beep, you have to go into the log book (event log).

To access the event log (during standby mode), press

The log book will automatically display all events starting with the last one. The data of each event is displayed on two areas, each one appears for 5 seconds before the next area/event is shown.

You can display the desired events manually.

to return to standby mode.

VOICE MEMO (VOICE MESSAGES)

To record a message (max.) 30s Duration), use the message recording function on the control center as follows:

to start the recording.

During recording, press

to stop the recording and delete the remaining time.

If 6 messages have already been recorded, no further voice message can be recorded until a message is deleted.

Access to the message announcement can be obtained either via the radio control center (see Message Repetition) or through the function on the radio operating field.

REPLAY MESSAGES (MESSAGE PLAYBACK)

If the ‘message’ LED lights up, this shows that either a new message is on the answering machine or the message announcement and has not yet been listened to. You can access the recorded messages at the control center as follows:

The messages are played back, starting with the last one recorded. Press

To get to the end of the news.

At the end of each message, there is a possibility to delete the just listened-up message.

To delete the message

to confirm the deletion and actually remove the message.

, to undo the deletion process and get to the next message.

After all messages are played, the system automatically switches back to standby mode.

REMOTE SYSTEM CONTROL (ON-THE-GO PHONE REMOTE CONTROL)

When the remote control function is switched on, the system receives the call after the programmed number of ringing tones and outputs three beeps, whereupon the caller is asked to enter the user code on the telephone keyboard.

A valid user code is confirmed by a long beep. An invalid code is signaled by two short beeps.

Show 4 more labels / short text on this page
With the keys · , · . User access code
Page 54 of the Friedland SA5F user manual — Part-Arm 2 Setup (Partially Setting)
Page 54 · click to enlarge
Page 54

If the user code is not entered within 30 s or an invalid code is entered more than three times, the central control unit automatically terminates the connection.

Use of an external answering machine:

If the remote control is used in conjunction with an external answering machine, you must consider the following points:

1. The internal answering machine must be switched off.
2. The number of rings to answer for the radio control centre must be greater than that for the external

An answering machine, as otherwise the central station always takes up the call before

Turns on answering machine.

To access the telephone remote control, the central office has a “double dial-in” function to enable the central station to answer the call before the external answering machine turns on. This procedure is as follows:

1. Call the system and hang up after two ringtones.
2. Call the system again within 30 seconds and the system will call at first

Take the ringer.

3. Enter the user code as usual.

The following functions can be set via the telephone remote control. The system will confirm each signal with a long beep.

, to switch sharply.

, to switch partly sharp-1.

, to switch partly sharp-2.

to make the system fuzzy.

to stop the siren.

to turn on the siren.

, to listen through the microphone of the control center.

to stop listening.

, to query the system status. The status is repeated at the 2s interval for 15s.

A beepSharp
Two beepsPartial sharpness (1 or 2)
Three beepsAlarm triggered
A long beepFuzzy

, to reproduce messages from the answering machine.

When a message is being played, press

for 2 seconds to get to the end of the message and listen to the next one.

to delete all messages of the answering machine.

, to terminate the connection with the radio control center.

Page 55 of the Friedland SA5F user manual — BATTERY MONITORING (BATTERY SURVEILLANCE)
Page 55 · click to enlarge
Page 55

BATTERY MONITORING (BATTERY SURVEILLANCE)

All devices that belong to the radio alarm system continuously monitor their battery status. The radio control center also monitors the battery ratios of all wireless motion detectors and magnetic contacts. If the battery status falls below an acceptable level, “lower battery status” is activated. In addition, it is displayed at the radio control center and recorded in the event memory if a wireless motion detector or magnetic contact has low battery status.

If a low battery status has been activated, the device will normally continue to function for up to 2 weeks (depending on system use). Nevertheless, the battery for each device should be replaced as soon as possible.

A low battery status is displayed on the devices as follows:

During the phase in which the control center is not connected to a socket, the control station is supplied with rechargeable backup batteries.

Under normal battery status, the Power LED light will be lit at 1s on the control center. At low battery status, the Power LED will light up at 3s intervals.

If the radio handheld transmitter operates only with a low battery status, the transmission LED continues to light after actuation of a button even after the button has been released again.

Under normal battery status, the transmission LED goes out again after releasing the button.

PIR Movement Detector (PIR Radio Motion Detection)

If the radio motion detector is operating with only a low battery status, the LED lights up behind the monitoring lens to signal that the battery must be renewed.

Under normal battery status, the LED will not light unless the radio motion detector is in “Walk Test Mode”.

Magnetic contact detector (radio magnetic contact)

If the radio magnetic contact operates only with a low battery status, this is indicated by the transmission LED which can be used for approx. 1 second after window/door has been opened.

Under normal battery status, the LED will not light up when magnetic contact has been activated (unless the detector is in test mode with the battery cover removed)

Control Panel (Radio control centre) · Remote control (radio handheld transmitter)

Page 56 of the Friedland SA5F user manual — BATTERIES (BATTERIES)
Page 56 · click to enlarge
Page 56

MAINTENANCE

Your plant requires only a small amount of maintenance. However, a few things should be considered so that your plant works reliably.

CONTROL PANEL (RADIO CENTRE)

The rechargeable batteries have an expected lifetime of approx. 4 years and do not require any maintenance during this time, except that they are charged. The batteries are damaged if they are stored with empty status for a long time.

DETECTORS AND REMOTE CONTROL (RADIO ALARMS AND HANDHELD TRANSMITTERS)

The detectors also require only a small amount of maintenance. Batteries should be renewed once a year or if low battery status is indicated.

BATTERIES (BATTERIES)

Before you remove the battery covers or open the control panel, make sure that the system is put into test mode to prevent a full alarm from being triggered.

The specific requirements for the batteries are as follows:

Radio control centre2 x 6V/1.2Ah battery
Radio handheld transmitters1 x 3V CR2032 lithium battery
Radio magnetic contact2 x 3V CR2032 lithium battery
Radio motion detectors1 x 9V block battery 6LR61

At the end of battery life, batteries should be disposed of in accordance with regulations. Do not dispose of them together with your household waste. DO NOT BURN IT AT ALL.

The rechargeable batteries contain Sulphuric Acid – DO NOT OPEN THE Housing.

Page 57 of the Friedland SA5F user manual — Remote Security Manager Service
Page 57 · click to enlarge
Page 57

ALARM RECORD (ALERT RECORDING)

Fill in the following boxes during installation to have an overview of future applications when expanding your plant and as a help with possible problem management.

Friedland SA5F — ALARM RECORD (ALERT RECORDING) diagram (page 57)
Fig. 32

You can then also write down user codes and installation access code.

System Access Codes (SYSTEM ACCESS CODE)

User 1User 2: User 3:
User 4User 5: User 6
Master User (main user)

System House Code (SYSTEM-HAUS-CODE)

Use the above representation to get your house code etc. to be recorded.

Voice Dialler Phone Numbers (TELEFONSELECTION NUMBER)

Phone No 1Phone No 2:
Phone No 3Phone No 4:

Latch-Key Phone Numbers (HOUSE KEY TELEFONNUMBERS)

Phone No 1Phone No 2:

Remote Security Manager Service

Phone NoSystem ID No:

This information shall be kept confidential and in a secure place.

Page 58 of the Friedland SA5F user manual — TROUBLE SHOOTING (TEST MANAGEMENT)
Page 58 · click to enlarge
Page 58

TROUBLE SHOOTING (TEST MANAGEMENT)

Central does not work – Power LED OFF (OFF) or lights up.

1. Central power is not working – check if other devices are working.
2. Check if the power adapter is plugged into the outlet and whether there is voltage on the socket.
3. Check if the DC (DC) plug of the power adapter is connected to the control center.
4. Check the fuses in the building.

The telephone dialing device is not working.

1. Make sure that it is an analog telephone connection.
2. Phone line not connected or faulty – check the phone connection with another telephone.
3. Selection method could be incorrectly programmed
4. Wrong phone number could be programmed
5. No alarm message was recorded
6. Phone numbers may be switched off in the call order
7. Take a break of 3.5 seconds before the area code

The LED at Line Status flashes and the system makes beeps.

1. Check the telephone cable for breaks. Check if the telephone cable is connected.
2. Delete the phone numbers and set the call orders all to OFF. After that, remove the batteries and power adapter and connect them again. Reprogram the telephone dialing device.
3. LINE connection must be busy.

Phone dialing device does not respond to an alarm

1. Phone line not connected faulty – check the phone connection with another telephone
2. Selection method could be incorrectly programmed
3. Wrong phone numbers could be programmed
4. Phone number could be off in call order
5. No alarm messages were recorded

Answering service does not respond or receive messages

1. Phone line not connected or faulty – check the phone connection with another telephone
2. Selection method could be incorrectly programmed
3. Answering service could be turned off
4. No room for more messages, as 6 messages have already been recorded

Voice message cannot be recorded at central station.

1. No room for more messages, as 6 messages have already been recorded

The radio control center does not contact the service guard in case of an alarm

1. Phone line not connected or faulty – check the phone connection with another telephone
2. Selection method could be incorrectly programmed
3. Wrong phone number for service guards could be programmed
4. Wrong system identification number (system ID) for the service guard service could be programmed
5. Service security service might not have been paid or there is no contract

Radio control center does not respond to telephone remote control from the road

1. Phone line not connected or faulty – check the phone connection with another telephone
2. Telephone remote control switched off
3. Wrong user access code was entered

Symptom / Recommendation

Page 59 of the Friedland SA5F user manual — Part-Arm 2 Setup (Partially Setting)
Page 59 · click to enlarge
Page 59

Door key (latch-key) does not work if the system is fuzzy

1. Phone line not connected or faulty – check the phone connection with another telephone
2. Selection method could be incorrectly programmed
3. The key (latch-key) could be turned off
4. The door key (latch key) is set for selected users and not unlocked for the user who fuzzes the system
5. No latch-key phone numbers were programmed

Radio control center does not accept the user access code.

1. Pause between pushing the buttons could have been too long. Wait no longer than 5 seconds between pressing the single button.
2. Wrong code was entered. Let it pass 5 seconds before entering the correct code.
3. In programming, go back to the factory setting and program again.

Radio control center does not respond to radio detector

1. Make sure the house code is set correctly.
2. Make sure the radio detector is in an effective wireless range to the control center and that devices have not been attached near metal objects.
3. Low battery status of the radio detector – Replace the battery in the alarm
4. The headquarters no longer reacts. She no longer takes orders. In programming, go back to the factory setting and program again. See page 28.

A full alarm was triggered, although the system is fuzzy and has not been triggered.

1. Sabotage switch has been activated

a. Check all battery covers to see if they are mounted correctly.

b. Check that the control center is properly mounted on the wall and the sabotage switch is closed.

2. Panic alarm was triggered by the radio handheld transmitter or control center.
3. Check whether the different zones are not set 24 hours of break-in (24h intruder).

LED of the handheld radio transmitter does not light or only faintly when the device is working

1. Make sure the batteries are connected correctly (watch for polarity).
2. Make sure the battery ports are in order.
3. Replace the batteries.

PIR radio motion detector triggers false alarm

1. Make sure the radio motion detector is not aligned with a heat source or moving objects.
2. Make sure the radio motion detector is not mounted over a heat source
3. Make sure the radio motion detector is not frontally aligned with a window or direct sunlight.
4. Make sure the radio motion detector is not in a pass area.
5. Too low a pulse count setting – set up two-pulse monitoring.

PIR radio motion detector does not respond to a movement.

1. Check if the battery connection is in order.
2. Too high a pulse number setting – set to one-pulse monitoring.
3. Check whether the detector is set correctly (see settings of PIR radio motion sensor)
4. Make sure that the SW3’s DIP switches 1-4 are set correctly.
5. Make sure the detector has been mounted around correctly (monitoring lens below).
6. Make sure the detector has been mounted at the correct height (2 – 2.5m).
7. Allow the detector up to three minutes for stabilization.
Page 60 of the Friedland SA5F user manual — Part-Arm 2 Setup (Partially Setting)
Page 60 · click to enlarge
Page 60
8. Make sure the detector is in effective radio range to the control center and not mounted near metal objects that could interfere with the radio signals.

PIR radio motion detector LED lights up when monitoring movement (device is in the normal mode.

1. Low battery status – replace the battery.

Radio magnetic contact does not work.

1. Make sure the battery connection is in order, and with the right polarity.
2. Make sure the house code is set correctly.
3. Make sure that the DIP switches 9, 10 and 11 are set correctly.
4. Make sure the detector is in effective radio range to the control center and not mounted near metal objects that could interfere with the radio signals.
5. If no additional wired magnetic contact detector is connected, then make sure that the jumper link is mounted.
6. Should an additional wired magnetic contact be connected:

a. Make sure the jumper link has been removed.

b. Make sure the extra contact is wired properly.

c. Make sure that the magnet is correctly aligned with the detector and that the distance between the magnet and the detector is not too large (see instructions from external magnetic contacts).

Note: If you are using an additional wired detector, please note that windows/doors monitored by both detectors (wired or wireless) closed if an extra contact is used then the doors/windows protected by both the main wirefree detector and the additional wire detector must be closed when either is opened. If one of the doors/windows is already open then the opening of the other door/windrow will not be detected.

Radio magnetic contact triggers false alarm

1. Make sure the magnet has been correctly aligned and positioned with respect to the detector
2. Make sure that the distance between magnet and detector is less than 10mm.
3. Sabotage switches below the battery are not properly installed – check that the battery cover is slipped on correctly and that the mounting bracket has not been broken.

LED of the radio magnetic contact lights up when window/door is opened

1. Low battery status – replace the batteries.

The solar exterior siren triggers an alarm without the system being sharp. The sound is reproduced, which also when the sabotage switch is triggered,

1. Sabotage switch has been activated
1. Check all battery covers to see if they are mounted correctly.
2. Check that the control center is properly mounted on the wall and the sabotage switch closed
2. Sabotage switches continue to press in, so there is less play (hard object behind the sabotage button).
Page 61 of the Friedland SA5F user manual — ACCESSORIES
Page 61 · click to enlarge
Page 61

EXTENSION OF THE RADIO ALARM SYSTEM

You can extend your system to provide additional monitoring and protection by installing extra radio magnetic contacts, wireless motion detectors, radio control panels, handheld transmitters and exterior siren.

ACCESSORIES

Friedland SA5F — ACCESSORIES diagram (page 61)
Fig. 33
Page 62 of the Friedland SA5F user manual — RESEARCH & DEVELOPMENT (RESEARCH AND DEVELOPMENT)
Page 62 · click to enlarge
Page 62

If you cannot handle a problem independently, please call the hotline:

Technical hotline 0900 1290468

0900 1290468 (0,93 € / Minute)

(cost)0.93 Euro/min from the Dt. Fixed network, mobile prices may differ from this

(Mondays to Thursdays from 07:30 until 16:00, Fridays from 7:30 to 13:00)

Most problems can be solved quickly on the phone.

You also have the option to send us an email at the following address:

[email protected]

[email protected]

GUARANTEE

This product (except the batteries) has a two-year warranty on materials and operating activity from the date of purchase. We will repair or replace any defective product. No liability can be for wear,

Negligence of the buyer, improper assembly or use, local radio interference, intentional or

unintentional damages are assumed. This guarantee does not affect your positive rights.

If an appliance is defective, the product must be sent in adequate packaging to the address below.

returned with:

1. A copy of the original invoice/receipt.
2. A detailed description of the error.
3. All relevant batteries.

NOTE:

If you are sending in a system, make sure that all batteries have been disconnected/interrupted and that the

The device is adequately packaged so that no damage can occur during transport.

For security reasons, it is recommended to send by registered mail.

NOVAR GmbH - Business Unit Friedland

Am Hammer 10, 51647 Gummersbach, Germany

Novar GmbH a Honeywell Company Office Northern Europe Business Unit Friedland Brodhausen 1, 51491 Overath

Novar Electrical Devices and Systems.

The Arnold Centre, Paycocke Road, Basildon, Essex. SS14 3EA. UK

Phone: +49 (0) 2204 - 76717 - 0 Fax: +49 (0) 2204 - 76717 - 10

E-mailinfo@de. friedland.eu www.friedland

RESEARCH & DEVELOPMENT (RESEARCH AND DEVELOPMENT)

Our research and development department is continuously developing new products.

We practice a policy of continuous improvement and reserve the right to change specifications without prior notice.

Page 63 of the Friedland SA5F user manual — PIR radio motion detectors
Page 63 · click to enlarge
Page 63

SPECIFICATION OF EQUIPMENT

RADIO CONTROL CENTRE

Friedland SA5F — RADIO CONTROL CENTRE diagram (page 63)
Fig. 34
  • Radio frequency: 433 MHz
  • Radio-incident monitoring
  • 6 users + main user
  • 6 radio zones
  • Independent programming of the access and initial delay time.
  • Removal zones
  • Quick adjustment and setting of the last exit
  • Transit zones
  • Gong
  • Sabotage protection on the front and back
  • Panic alarm function (PA)

Radio handheld transmitters

Friedland SA5F — Radio handheld transmitters diagram (page 63)
Fig. 35 · Radio handheld transmitters
  • Radio frequency: 433 MHz
  • Range: 50m max.
  • Controls all sharpness/partial focus unfocus functions
  • Panic Switch (PA)
  • Transmission indicator
  • Battery life > 1 year
  • Low battery status is displayed

PIR radio motion detectors

Friedland SA5F — PIR radio motion detectors diagram (page 63)
Fig. 36 · PIR radio motion detectors
  • Radio frequency: 433 MHz
  • Range: 75m max.
  • Monitoring range: up to 12m at 110° 7 and 6m at 180°
Page 64 of the Friedland SA5F user manual — External radio external siren with solar operation (optional)
Page 64 · click to enlarge
Page 64
  • Run test function
  • One or two pulse number monitoring
  • Anti-sabotage protection
  • Corner or surface assembly
  • Battery life > 1 year
  • Low battery status is displayed

Radio magnetic contact

Friedland SA5F — Radio magnetic contact diagram (page 64)
Fig. 37 · Radio magnetic contact
  • Radio frequency: 433 MHz
  • Range: 75m max.
  • Test mode
  • Anti-sabotage protection
  • Device for additional wired magnetic contacts
  • Battery life > 1 year
  • Low battery status is displayed

External radio external siren with solar operation (optional)

Friedland SA5F — External radio external siren with solar operation (optional) diagram (page 64)
Fig. 38 · External radio external siren with solar operation (…
  • Radio frequency: 433 MHz
  • 6V/1.2Ah Buffer battery
  • Solar Panel 7.5V – Charge Rate 60mA
  • Operation time in complete darkness – up to 25 days
  • 95dB high performance piezo siren
  • After 3 minutes, the alarm turns off (up to 3 min). Selectable
  • Siren can be switched off at central
  • Anti-sabotage protection on the front and back
  • Integrated radio interference protection
  • LED stroboscopic light
  • Status indication by flashing lamp
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Friedland SA5F

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Friedland SA5F

Be the first to ask — other owners or our team will answer.

Original document

Friedland SA5F manual PDF

64 pages·2.6 MB·Security·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…