ANALOGUE ENGLISHp.1Date Modelsp.13 hands day date VJ55A / VX43p.1DAGp.1VJ55Ap.13-handlers with alarm function ISA 8176-1990p.2ALARM POINTERp.2Reset the date with sweep function VD86A / VD85Jp.2DAY OF THE WEEK DATEp.2SECOND HANDp.2VD86Ap.2DAG VAN DE WEEKp.2VD85Jp.2Backwards Triple-View Date with Day Marker JR00p.2DATE 24-HOURp.2WEEKDAYp.23 Time zones 9238 / 1980p.2TWO TIME ZONESp.2Two time zones VX01p.3TIJD A TIJD Bp.3ANALOG - DIGITALp.4Analog Digital FL1331Ap.4Analog Digital FL202p.4Analog Digital QFL133p.5Ana-Digi QFO-017 / Y121E6p.5World Time Module (Analog Digital and Digital)p.6AUTOMATIC / MECHANICALp.7Automatic winding-up mechanismsp.782S7 24 HOURS SECONDSp.782SOp.7TY2723p.7TY2542p.7Automatic 2876p.7MONTHp.7C Ap.724 HOUR POINTERp.7ENERGY SERVICE Automatic TY2714p.8MINUTEHANDp.8HOUR HANDp.8SECONDHANDp.8MULTIFUNCTIONp.9Multifunction 6P25p.9Multifunction VX3R / VX 3REp.924-UURSp.9Multifunction VD75A1p.9SMALL SECONDS HANDp.9Multifunction 6P27 / 6P29 / 6 P77 / 6p79 / VX3NEp.9DAY DATEp.96P27 / 6P77p.9DATE 24-HOURp.96P29 / 6P79p.924-UURS DAGp.9VX3NEp.9Multifunction VX3JEp.1024-UURp.10Multifunctional JP25p.1024 UURp.10B TWO TIME ZONESp.10Multifunctional with alarm 8176-1990p.10SECONDSHANDp.10SECOND TIME ZONE POINTp.10Multi-Time Zone 505.24Hp.11SECOND TIME ZONE POINTERp.11CHRONOGRAPHp.12Chronograph OS11p.12MINUTE-HAND CHRONOGRAPHp.12Chronograph JS05 / JS06 / Js15 / J S16 / J s25 / Jp.1224 HOUR GUIDEp.12CHRONOGRAPH MINUTE HANDp.12CHRONOGRAPH SECOND HANDp.12JS05/06p.12JS15/16p.12JS25/26p.12Chronograph 6S20p.13MINUTEHANDp.131/20 SECOND HAND CHRONOGRAPHp.13Chronograph VD51Bp.13CHRONOGRAPH SECONDHANDp.13Chronograph VK61 / VK64p.14DATE MINUTE POINTERp.14
Page 1 of the Fossil FO-001 user manual — DAG
Page 1 · click to enlarge
Page 1

For older watches, please contact customer service in your country.

You can find the contact information on the website's customer service page.

ANALOGUE ENGLISH

Diagram . .
Diagram . .

Time and Date Settings 1. Pull the crown to position 2 and turn it to set the hour- and minute-hand. 2. Bring the crown back to position 1. NOTE: Large pointer shows the hour; minutes are shown by the black arrow on the picture.

Date Models

Set Date 1. Pull the crown out to position 2. 2. Turn the crown clockwise or counterclockwise and set the date of the previous day. The direction in which the date moves differs by watch model.

Set Time 1. Pull the crown out to position 3. 2. Turn counterclockwise to move time forward and continue until the day changes into today's. 3. Set to the right time. 4. Press the crown back into position 1. NOTE: If the watch does not have a date function, pull the crown to position 2 to set time. 1 2 3

Diagram . .
Diagram . .
1. Pull the crown out to positive 2. 2. Turn the crown to set the hours of minute hand. NOTE: Sun/Moon disk moves together with the hours and minute pointers and will indicate time in vm/nm. 3. Bring the crown back to position 1.

3 hands day date VJ55A / VX43

DAG

Set Day 1. Pull the crown out to position 2. 2. Turn the crown to the right until you see the correct day in the daily window. 3. Turn the crown back to position 1. NOTE FOR VX43: Sunday: Round window has solid color (show full moon). Monday - Friday: While the watch adapts from Monday to Friday, the round window shows a half moon, where the bottom of the moon corresponds to the specific day in the window at the bottom. The half moon is reduced as the days of the week progress. Saturday: Window has solid color (no moon).

VJ55A

Set time and date 1. Pull the crown out to position 3. 2. Turn the crown left until the right time is displayed. 3. Turn the crown clockwise for 24 hours until the correct date is displayed. 4. Turn the crown back to position 1.

DAG

revised 07/15

Page 2 of the Fossil FO-001 user manual — TWO TIME ZONES
Page 2 · click to enlarge
Page 2

3-handlers with alarm function ISA 8176-1990

Set Time 1. Pull the crown out to position 3. 2. Turn the crown clockwise to move forward the hour and minute hand. 3. Turn the crown back to position 1.

Set alarm 1. Pull the crown out to position 2. 2. Turn the crown to the left to set the alarm pointer. 3. Turn the crown back to position 1.

ALARM POINTER

Alarm function 1. Press A to turn on/off the alarm. Alarm will beep twice to indicate that it is the alarm . . and will only squeak once to indicate the alarm is off . 2. Alert will sound for 15 seconds. Press "A" to disable the alarm. NOTE: If A is not pressed, the alarm will go off after a minute.

Reset the date with sweep function VD86A / VD85J

DAY OF THE WEEK DATE

Time and Date Setup 1. Pull the crown out to position 3 and turn clockwise to set the day of the week. The clock on the left indicates the day of the week and will automatically jump back to . 2. Hold the crown in position 3 and turn the hands to set time (make sure am/pm is correctly set. 3. Press the crown back to position 1. 4. Pull the crown to position 2 and turn counterclockwise to set the date. 5. Press the crown back into position 1.

SECOND HAND

VD86A

DAG VAN DE WEEK

SECOND HAND

VD85J

Backwards Triple-View Date with Day Marker JR00

DATE 24-HOUR

Time, Date and Weekday Setting 1. Apply the crown to position 2 and turn it against pointer to set last week's date. 2. Turn the crown clockwise to take the weekday to the next day. NOTE: Weekday indicator will be automatically reset to .m.m at the end of the weekday cycle. 3. Pull the crown out to position 3, and turn it in pointer until the current date and working day are shown. Keep turning to set the correct vm/nm time. 4. Bring the crown back in position 1.

WEEKDAY

3 Time zones 9238 / 1980

Set Time 1. Pull the crown out to position 2. 2. Turn the crown to move forward the hour and minute hand. 3. Turn the crown back to position 1.

Set two time zones Press A to move forward to the desired time.

TWO TIME ZONES

Page 3 of the Fossil FO-001 user manual — TIJD A TIJD B
Page 3 · click to enlarge
Page 3

Two time zones VX01

Set Time A 1. Pull out crown A to position 2 when the second hand is at 12 o'clock. 2. Turn the crown to set the desired time. 3. Turn the crown back to position 1.

TIJD A TIJD B

Set Time B 1. Pull out crown B to position 2 when the second hand is at 12 o'clock. 2. Turn the crown to set the desired time. 3. Turn the crown back to position 1.

NOTE: When the minute pointer is set, turn it 4 to 5 minutes further than the time you want and then turn it back to the exact time.

Page 4 of the Fossil FO-001 user manual — Analog Digital FL202
Page 4 · click to enlarge
Page 4

ANALOG - DIGITAL

Analog Digital FL1331A

Normal Time View 1. Press A or B for electron lumino-infectient. 2. Press and hold A or B for 2 seconds to turn off the digital screen. Press any button to enable the screen when it is disabled. 3. Press C to switch between 12- and 24-hour format. The display will show .AM or .PM/P.M. for the 12-hour format. 4. Press D to change mode. The sequence of modes is time, date, stopwatch, alarm. Note: In all setting modes, when a button is not pressed for 30 seconds, all changes will be saved and the setting will automatically jump back to display mode.

3. Press C to start or stop the stopwatch. 4. Press D to return to zero.

Time and Calendar Settings 1. Press, in normal time view or calendar display on C for 2 seconds, the year will begin to blink. 2. Press D to increase the numbers; press and hold D to raise faster. 3. Press C to go to the next setting value. 4. The order of institutions is: year, month, date, hour, minute, seconds. 5. Press C to exit the settings. Note: The day of the week will be automatically updated when leaving settings.

Alarm mode 1. Press D to go to alarm mode. 2. Press C to turn on or off the alarm/clock game. 3. The alarm will go off at a preset time for 20 seconds; press any button to turn off the alarm.

Alarm Setup 1. Press and hold C for 3 seconds in alarm mode, hour will start blinking. 2. Press D to increase the number; press and hold D to raise quickly. 3. Press C to set and continue to minute. 4. Press D to increase the number; press and hold D to raise quickly. 5. Press C to exit the settings.

Stopwatch mode 1. Press D to go to stopwatch mode. 2. Press D and hold for 2 seconds to return the stopwatch to zero.

Analog Digital FL202

Normal Time View 1. Press A to choose from 12/24U format. 2. Press B to change the view mode. Display order is time, calendar, seconds.

Time/Calendar Setting 1. Press and hold A from any view mode to access setting mode; the year will start blinking. 2. Press B to continue with the next setting. Press B and hold it to continue quickly. 3. Press A to set and proceed to the next setting. 4. Setting order is: year, month, date, hour, minute. 5. Afterwards, automatically revert to the display mode after minutes are set or if nothing was pressed for 30 seconds. NOTE: When setting the hour, the figures are displayed in the 24-hour system.

Page 5 of the Fossil FO-001 user manual — Ana-Digi QFO-017 / Y121E6
Page 5 · click to enlarge
Page 5

Analog Digital QFL133

Normal Time View 1. Press A to change mode. The order of the settings is normal time display, alarm, stopwatch and time/calendar setting. 2. Press B for electroluminescent. 3. Press C to switch between 12- and 24-hour time. Note: In all setting modes, when a button is not pressed for 2 minutes, all changes will be saved and the setting automatically jump back to normal time view.

Time and Calendar Settings 1. Press A to go to time/calendar setting mode; seconds will start blinking. 2. Press C to set seconds to zero. 3. Press D to go to the next setting value. 4. Press C to increase the number, press and hold C to raise quickly. 5. The order of settings is: seconds, hours, minutes, months, dates and days of the week. 6. Press A to exit the settings.

4. Press C to increase minutes; press and hold C to raise quickly. 5. Press D to save the settings and exit the setting; press A to save settings, leave the setting and return to normal time view.

Alarm mode 1. Press "A" to go into alarm mode. 2. Press C to turn on or off the alarm/clock game. 3. The alarm will go off at a preset time for 20 seconds; press C or D to turn the alarm off.

Stopwatch mode 1. Press A to go to stopwatch mode. 2. Press C to start or stop the stopwatch. 3. Press D to return to zero.

Interval 1. Press D while the stopwatch runs to determine the interval. 2. Press D again to return to the stopwatch. 3. Repeat steps 1 and 2 to measure multiple intervals. 4. Press C to stop recording time. 5. Press D to return to zero.

Alarm Setup 1. Press and hold D in alarm mode to go to settings mode; hour will start blinking. 2. Press C to increase the hour; press and hold C to raise quickly. 3. Press D to set and continue to minutes.

Ana-Digi QFO-017 / Y121E6

Set time and calendar 1. Press A for EL. 2. Press C for 2 seconds to set the time. The seconds will blink. 3. Press D to reset time to zero. 4. Press B to switch by the following setting options: Seconds . . Minutes . Press D to set the blinking item. 6. The day of the week is automatically displayed in accordance with the date (month, day, year). 7. Press C to return to the mode with current time.

Alarm mode 1. Press B to switch to alarm mode. 2. Press D to turn on/off the alarm or alarm message. 3. The alarm will sound at the preset time for 20 seconds.

Timer 1. Press B to switch to timer mode. 2. Press C for 2 seconds to display the timer setting. 3. Press B to select the .Uura or .Minutes . and press D to set the blinking item. 4. Press C to complete the settings. 5. Press D to start/stop the timer. 6. Hold C down to reset the timer.

Set alarm 1. Hold down the alarm mode for 2 seconds C to set the . 2. Press B to set the . 3. Press D to set the blinking item.

Chronograph mode 1. Press B to switch to chronograph mode. 2. Press D to start/stop the chronograph. 3. Hold C to reset the chronograph to zero. 4. Press C when the chronograph is running, to display the split count. 5. Press D to close the split count and stop the count. 6. Hold C to reset the chronograph to zero.

Two time zones 1. Press D to switch to the two timezone mode. 2. Hold C for 2 seconds to select the . 3. Press B to select the . 4. Press D to set the blinking item. 5. Press C again to complete the setup.

Page 6 of the Fossil FO-001 user manual — World Time Module (Analog Digital and Digital)
Page 6 · click to enlarge
Page 6

World Time Module (Analog Digital and Digital)

Normal Time View 1. Press button B for electron lumininecent. 2. Press C button to turn the setting off or off every hour. 3. Press D button to switch on or off summer time for the selected city. 4. In each mode or setting, when no button is pressed for 60 seconds, the setting will be restored to normal time view.

Time and Calendar Mode 1. Press and hold button B for 2 seconds to open the count mode. 12-/24-hour time will begin to blink. 2. Press C button to select 12-/24-hour time. 3. Press button A to select seconds, minute, hour, year, month, day and city and change. 4. Press C to increase the number; press D button to lower the digit. 5. Press B button to exit the settings.

World Time Mode 1. Press button A to select world time mode. 2. Press C button to select a city. 3. Press D button to switch on or off summer time for the selected city.

WordsCityTime differenceWordsCityTime difference MDY HNL ANC LAX DEN CHI NYC CCS RIO -2H -1H LONMidway Honolulu Anchorage Los Angeles Denver Chicago New York Caracas Rio de Janeiro -2H -1H London-11 hours -10 hours -9 hours -8 hours -7 hours -6 hours -5 hours -4 hours -3 hours -2 hours -1 hours 0 hoursPAR CAI MOW DXB KHI DAC BKK HKG TYO SYD NOU AKLParis Cairo Moscow Dubai Karachi Dacca Bangkok Hong Kong Tokyo Sydney Noumea Auckland+1 hours +2 hours +3 hours +4 hours +5 hours +6 hours +7 hours +8 hours +9 hours +10 hours +11 hours +12 hours
Diagram . .
Diagram . .

Alarm Setting (3 alarms) 1. Press button A to select alarm mode. 2. Press button C to walk through the alarms. 3. Press button D to turn the alarm on or off. 4. Press and hold button B for 2 seconds to open the count mode. Minutes will start blinking. 5. Press button A to select minutes and hours. 6. Press C to increase the number; press D button to lower the digit. The alarm will be activated automatically when the setting is changed. 7. Press B button to exit the setting mode.

Stopwatch mode 1. Press button A to select stopwatch mode (STW). 2. Press C button to start the stopwatch; press D button to stop the stop watch. 3. Press the D button to reset stopwatch when it is not running.

Rounds Count 1. Press button C while the stopwatch runs (will record up to 20 rounds). 2. Press button D to stop recording time. 3. Press button A to show rounds (TOT) when information is stored by the stopwatch (will display up to 20 rounds). 4. Press C to view the next round; press D button to see the previous round. 5. Open regular stopwatch mode; press D button to reset to zero.

Timer 1. Press button A to select timer mode. 2. Press button C to start or stop the timer. 3. Press the D button to reset the timer when it is not running. Timer will show zeros before restarting the timer. 4. Press and hold button B for 2 seconds to open the count mode. Seconds will begin to blink. 5. Press button A to select seconds, minutes and hours. 6. Press C to increase the number; press D button to lower the digit. 7. Press B button to exit the setting mode.

Page 7 of the Fossil FO-001 user manual — WEEKDAY
Page 7 · click to enlarge
Page 7

AUTOMATIC / MECHANICAL

Automatic winding-up mechanisms

A watch with an automatic winding mechanism has the ability to wind itself up when moving your wrist, no battery is needed. Therefore, it cannot carry the watch several days in a row exhausts its energy reserve. If your watch stops, it is recommended that you turn the mechanism manually by turning the crown clockwise to generate the necessary buoyancy reserves.

It is important that your watch is adapted to the size of your wrist. If the watch is too loose, the ability of the watch to wind itself can be reduced. If completely excited, your watch has a driving power reserve of approx. 36 hours.

Diagram . .
Diagram . .

Manually turned-up mechanical TY2809 / 6T33 / NH38 / NH39 / 8N24 / 82S7

1. To wind the watch up when it is completely stationary, turn the crown 20-25 times to the right (or until you feel resistance) in position 1. 2. After the watch has turned up, pull out the crown to position 2 and turn right or left to set time. 3. Turn the crown back to position 1.

82S7 24 HOURS SECONDS

Diagram . .
Diagram . .
1. Pull the crown out to position 2. 2. Turn the crown clockwise to set the hour and minute forwards. 3. Press the crown back to position 1.

NOTE: A watch that turns automatically on, takes the ability to wind itself up from your wrist movement, there is no battery. The failure to wear the watch for several consecutive days can therefore exhaust the power reserve. If your watch stops, it is advisable that you turn the watch manually by turning the crown in position 1 to the right to achieve the necessary power reserve.

82SO

It is important that your watch is adjusted to the size of your wrist. If you wear the watch too loose, then this may lead to loss of ability of the watch to turn itself on. Your watch has a power reserve of about 36 hours if this is completely turned on.

Diagram . .
Diagram . .
1. To start the timekeeping, the crown should be turned clockwise 15 to 20 times in position 1. 2. Pull the crown to position 2 and turn clockwise to set time. Press the crown back into position 1.

TY2723

TY2542

Automatic 2876

MONTH

1. To start tracking time, turn the crown in position 1 clockwise 15-20 times. 2. Pull the crown to position 2 and turn clockwise to set the hour- and minute-hands. The 24-hour hand moves along with the hour and minute hands. Use the 24-hour hand to set the correct AM/PM time. Press the crown back to position 1. 3. Press A to adjust the weekday. Every push on pushbutton A will advance one day the weekday. 4. Press B to adjust the month. Each push on pushbutton B will take the month with one step forward. 5. Press C to change the date. Each push on pushbutton A will set the date one day ahead. NOTE: Do not change the date between 22:00 and 02:00. This could affect the precision of the clock.

WEEKDAY

C A

24 HOUR POINTER

Page 8 of the Fossil FO-001 user manual — HOUR HAND
Page 8 · click to enlarge
Page 8

ENERGY SERVICE Automatic TY2714

MINUTEHAND

1. To start with time, turn the crown in dials up to position 1 until the hand of .---/-- (low reserve) switch from .‐--to .+--[--]-- --- ...to um/--"--"--*---" -- "--." 2. Pull the crown out to position 2 and turn it around to set time. Bring the curl back to position 1. 3. Press A to set date. Each push on pushbutton A will advance the date with one unit. NOTE: Do not set the date and week between 10pm and 04h00. If you do, this may affect the accuracy of movement.

HOUR HAND

SECONDHAND

Page 9 of the Fossil FO-001 user manual — DATE 24-HOUR
Page 9 · click to enlarge
Page 9

MULTIFUNCTION

Multifunction 6P25

Set Date 1. Pull the crown out to position 2. 2. Turn counterclockwise to select date.

DAG

Set Day and Time 1. Pull the crown out to position 3 for time. 2. Turn clockwise to set the time and minute hand. The pointer indicating the weekdays will also move along with the time and minute hand. Keep turning until the day is right. 3. Press the crown back to position 1.

Multifunction VX3R / VX 3RE

24-UURS

Set Time 1. Pull the crown out to position 2. 2. Turn the crown clockwise to set time. 3. Replace the crown in position 1.

Note: The 24-hour hand moves according to the time and minute pointers. When setting the time, make sure that the 24-hour hand is set correctly.

Set Date 1. Pull the crown out to position 3. Turn the crown counterclockwise to set the date. 2. Replace the crown in position 1.

Multifunction VD75A1

DAG

Set Date 1. Pull the crown out to position 2. 2. Turn counterclockwise to set the date pointer forward. 3. Press the crown back to position 1.

SMALL SECONDS HAND

Set Day and Time 1. Pull the crown out to position 3. 2. Turn clockwise to move the time and minute hand forward. The pointer indicating days of the week will also be in tune with the time and minute hand. Keep turning until you've reached the desired day.

Multifunction 6P27 / 6P29 / 6 P77 / 6p79 / VX3NE

DAY DATE

Set Date 1. Pull the crown out to position 2. 2. Turn clockwise to set the date pointer forward. 3. Press the crown back to position 1.

24-UURS

6P27 / 6P77

Set Day and Time 1. Pull the crown out to position 3. 2. Turn clockwise to move the time and minute hand forwards. The pointer indicating the weekdays will also move along with the time and minute hand. Keep turning until the day is right.

DAG

24-hours Sub-Dial Setup The 24-hour hand moves along with the hour and minute hands. When setting the time, check that the 24-hour hand is set correctly.

DATE 24-HOUR

6P29 / 6P79

24-UURS DAG

VX3NE

Page 10 of the Fossil FO-001 user manual — ALARM POINTER
Page 10 · click to enlarge
Page 10

Multifunction VX3JE

Date Setting 1. Pull the crown out to position 2. 2. Turn against the pointer to advance the date indicator. 3. Press the crown back to position 1.

DAG

24-UUR

Day and Time Settings 1. Pull the crown out to position 3. 2. Turn in dial to advance hour and minute hand. The pointer indicating the days of the week will move along with the time and minute hand. Continue to spin until you reach the desired day.

24-hour count The movement of the 24-hour hand comes across with the hour and minute hands. When setting the time, please check that the 24-hour hand is set correctly.

Multifunctional JP25

24 UUR

Set date/time 1. Pull the crown out to position 2. 2. Turn the crown to the right to set time and date. 3. Turn the crown back to position 1. NOTE: If the time is set between 21:00 and 01:00, it may not change the next day.

DAG

B TWO TIME ZONES

Set Day 1. Pull the crown out to position 3. 2. Turn the crown to the right and set the day. 3. Turn the crown back to position 1.

Set two time zones 1. Press A to move the hand of the two time zones forward in steps of 15 minutes. 2. Press B to move the hand of the two time zones forward in 15-minute steps. NOTE: The pointer of the two time zones can be moved quickly by pressing A or B for a long time.

Multifunctional with alarm 8176-1990

SECONDSHAND

Set time and date 1. Pull the crown to position 2 and turn right to set the date to that of the previous day. 2. Pull the crown to position 3 and turn right until the current date is displayed. Keep turning the crown to set the right time (am/pm). 3. Turn the crown back to position 1. NOTE: To ensure accuracy, we advise you not to set the date between 21:00 and 00:30.

ALARM POINTER

SECOND TIME ZONE POINT

Set second time zone 1. Pull the crown out to position 2. 2. Press A to set the second time zone. NOTE: The second time zone is displayed in military time and is indicated on the outer part of the dial.

LET OPThe alarm pointer has another one

color the hands of the watch.

Alarm function 1. Press B to turn on/off the alarm. The alarm beeps twice to indicate that the alarm is . . and only beeping once to indicate the alarm . 2. The alarm will ring for 15 seconds. Press B to turn off the alarm. NOTE: If B is not pressed, the alarm will sound again after one minute and will be automatically disabled.

Set alarm 1. Pull the crown to position 2 and turn left to set the alarm pointer. 2. Turn the crown back to position 1.

- 1 0 -

Page 11 of the Fossil FO-001 user manual — SECOND TIME ZONE POINTER
Page 11 · click to enlarge
Page 11

Multi-Time Zone 505.24H

Time and Calendar Settings 1. Pull the RED crown B (at position 4:00) to position 2. 2. Turn the crown clockwise to set the date of the previous day. 3. Pull the crown out to position 3. 4. Turn the crown clockwise until today's date; set the right a.m. or p.m. Time in. 5. Replace the crown in position 1. N.B.: The second time zone hand will move in conjunction with hours and minutes hands. Set the time and minute pointers before setting the second time zone.

SECOND TIME ZONE POINTER

Second Timezone Setting 1. Pull the RED crown B (at position 4:00) to position 2. 2. Turn the crown counterclockwise to set the second time zone. 3. Replace the crown in position 1. Note: The second time zone pointer is read in 24-hour time, indicated on the oblique side.

Third Time Zone Read 1. Turn crown A clockwise or counterclockwise to match the current hour with the time zone of the present city. 2. To read the third time zone, locate the city that represents the new time zone. Each increase (to the right) stands for +1 hours; each decrease (to left) stands at -1 hour.

- 1 1 -

Page 12 of the Fossil FO-001 user manual — 24 HOUR GUIDE
Page 12 · click to enlarge
Page 12

CHRONOGRAPH

Chronograph OS11

MINUTE-HAND CHRONOGRAPH

Set Date 1. Pull the crown out to position 2. 2. Turn the crown left until the correct date is shown in the date window. 3. Turn the crown back to position 1.

SECONDSHAND

Set Time 1. Pull the crown out to position 3. 2. Turn the crown clockwise to move forward the hour and minute hand. 3. Turn the crown back to position 1.

Chronograph control 1. Press A to start/stop the chronograph. 2. Press B to reset.

Adjust Chronograph 1. Pull the crown out to position 3. 2. Press A to reset the second hand to . 3. Reset the watch to current time and turn the crown back to position 1.

Chronograph JS05 / JS06 / Js15 / J S16 / J s25 / J

24 HOUR GUIDE

Time and Date Setup 1. Pull the crown out to position 2. 2. Turn the crown clockwise until the date of the previous day is displayed in the date window. 3. Pull the crown out to position 3. 4. Turn the crown clockwise until the correct date is displayed in the date window. 5. Continue to rotate the crown around the correct a.m./p.m time. NOTE: The 24-hour hand moves along with the hour and minute hands. When setting the time check that the 24-hour hand is set correctly. 6. Press the crown back to position 1. NOTE: If the crown is in position 2, do not press the pushbuttons. Otherwise, the chronograph will turn hands. NOTE: Do not set the date between 9.00 p.m. 1.00 a.m. to ensure accuracy.

CHRONOGRAPH MINUTE HAND

CHRONOGRAPH SECOND HAND

JS05/06

24 HOUR GUIDE

CHRONOGRAPH MINUTE HAND

CHRONOGRAPH SECOND HAND

Chronograph 1. Press A to start/stop the chronograph. 2. Press B to move back to zero.

JS15/16

Chronograph Return to Zero 1. If one of the chronograph guides is not at zero-(12.00) position, pull out the crown to position 3. 2. Press A to turn the hands clockwise; press B to turn in the dials counterclockwise. Every time printed on A or B, the chronograph guides are set forward/backward. Or hold A or B pressed for quick forward/backwards. 3. When both hands are at zero, set the time back and bring crown to position 1. NOTE: Chronograph minute hand is synchronized with chronograph second hand while restoring from chrongraph to zero.

24 HOUR GUIDE

CHRONOGRAPH MINUTE HAND

CHRONOGRAPH SECOND HAND

JS25/26

- 1 2 -

Page 13 of the Fossil FO-001 user manual — CHRONOGRAPH MINUTE HAND
Page 13 · click to enlarge
Page 13

Chronograph 6S20

SECONDSHAND

CHRONOGRAPH

Set Date 1. Pull the crown out to position 2. 2. Turn the crown to the right to set the date pointer forward. 3. Press the crown back to position 1. NOTE: If the time is set between 21:00 and 03:00, it may be that the date does not switch to the next day.

MINUTEHAND

CHRONOGRAPH

SECONDSHAND

1/20 SECOND HAND CHRONOGRAPH

Set the time 1. Pull the crown out to position 3. 2. Turn the crown clockwise to move forward the hour and minute hand. 3. Press the crown back to position 1.

Chronograph 1. Press A to start/stop the chronograph. 2. Press B to reset to zero.

Reset of chronograph 1. If one of the chronograph guides is not in the zero position (12:00), pull out the crown to position 3. 2. Once press A to set the seconds hand of the chronograph in zero position. 3. Press B once to set the 1/20 second pointer of the chronograph in zero position. NOTE: The hands of the chronograph can be moved quickly by pressing A or B constantly. 4. Reset the time when both hands are in zero position and reset the crown to position 1.

Chronograph VD51B

CHRONOGRAPH SECONDHAND

Time and Date Settings 1. Before setting the time, you should make sure that both seconds and minute hands are at 12:00 and the chronograph is not running. See .Chronograph Operation . 2. Pull the crown out to position 2. 3. Turn the crown clockwise until the date of the previous day is displayed in the date window. 4. Pull the crown to position 3 when the second hand is at 12:00. The second hand will stop turning. 5. Turn the crown clockwise until the correct date is displayed in the date window. 6. Keep turning the crown to set correct time (AM and PM). 7. Press the crown back to position 1. NOTE: Do not press the pushbuttons when the crown is in position 2. The chronograph guides will move. NOTE: Do not set the date between 21:00 and 01:00. This can affect the precision of the clock.

CHRONOGRAPH MINUTE HAND

Chronograph Operation 1. Press A to start/stop the chronograph. 2. Press B to reset.

Interval 1. Press B while the chronograph is running. 2. Press B again to return to the chronograph. 3. Press A to end the stopwatch timing. 4. Press B to reset.

Chronograph Zero-Reset If for any reason the chronograph guides do not return perfectly to their zero position (12:00): 1. Pull the crown out to position 3. 2. Press A to reset the second hand chronograph or press B to resize the minute hand chrononograph. Any pressure on the push-button will make the corresponding hand move forward. If the buttons are pressed for more than two seconds, the corresponding pointer will continue to move forward continuously. NOTE: The chronograph minute hand goes forward together with the chrongraph second hand. 3. Return the crown to position 1 when the chronograph guides are reset to zero (12:00).

- 1 3 -

Page 14 of the Fossil FO-001 user manual — SECONDSHAND
Page 14 · click to enlarge
Page 14

Chronograph VK61 / VK64

DATE MINUTE POINTER

CHRONOGRAPH

Set time and date 1. Pull the crown to position 2 and turn left to set the date to that of the previous day. 2. Pull the crown to position 3 and turn right until the current date is displayed. Keep turning the crown to set the right time (am/pm). NOTE: 24-hour hand (VK64 model only) moves in combination with the minutes/hour hand and indicates am/pm time. 3. Turn the crown back to position 1. NOTE: To ensure accuracy, we advise you not to set the date and day of the week between 21:00 and 03:00.

1/5 SECOND DISPLAY CHRONOGRAPH

SECONDSHAND

VK61

MINUTEHAND

CHRONOGRAPH

24 HOUR HAND

1/5 SECOND DISPLAY CHRONOGRAPH

Chronograph function 1. Press A to start/stop the chronograph. 2. Press B to reset to zero. NOTE: The chronograph will automatically stop after a continuous 1 hour period.

VK64

Chronograph VK63

SECONDS HAND CHRONOGRAPH

24 HOUR HAND

Set Time 1. Pull the crown out to position 3. 2. Turn the crown to set your time (make sure AM/PM is correctly set). 3. Turn the crown back to position 1.

MINUTE-HAND CHRONOGRAPH

SECONDSHAND

Set Date 1. Pull the crown out to position 2. 2. Turn the crown to the right to set the date. 3. Turn the crown back to position 1. NOTE: Do not set the date between 21.00 and 30.00, otherwise the day may not change properly. If necessary, change the time first, set the date and then reset the right time.

Chronograph control 1. Press A to start/stop the chronograph. 2. Press B to reset.

Reset after battery change 1. Pull the crown out to position 3. 2. Hold B for two seconds and then let go. 3. By demonstration, the small seconds hand should move for ten seconds at intervals of two seconds. 4. Turn the crown back to position 1.

Chronograph stopwatch JS10

24 HOUR HAND

Set Time 1. Pull the crown out to position 2. 2. Turn the crown to set the desired time. 3. Turn the crown back to position 1.

MINUTE-HAND CHRONOGRAPH

SECONDS HAND CHRONOGRAPH

Use the stopwatch 1. Press A to start/stop stop the stopwatch and control the interval. 2. Press B to reset the stopwatch. NOTE: This stopwatch can measure and display time in 1/10 seconds to a maximum of 30 minutes. The stopwatch will automatically stop after a continuous 30 minute period.

SECONDSHAND

Reset Stopwatch 1. Pull the crown out to position 2. 2. Once press A to set the seconds hand of the chronograph in zero position. 3. After the hands are reset to zero, you can reset your desired time. 4. Turn the crown back to position 1. NOTE: This action must only be performed when the seconds hand of the chronograph does not return to its zero position.

- 1 4 -

Page 15 of the Fossil FO-001 user manual — 24 HOUR GUIDE
Page 15 · click to enlarge
Page 15

Chronograph Stopwatch OS10 (no date - OS30)

CHRONOGRAPH MINUTE HAND

Set Time 1. Pull the crown out to position 3. 2. Turn the crown to set the desired time. 3. Press the crown back to position 1.

CHRONOGRAPH HOUR

POINTER

SECONDHAND

Set Date 1. Pull the crown out to position 2. 2. Turn the crown counterclockwise until the correct date is displayed in the date window. 3. Press the crown back to position 1.

CHRONOGRAPH SECOND HAND

Chronograph Control 1. Press A to start/stop the chronograph. 2. Press B to move back.

Change Chronograph 1. Pull the crown to position 3. 2. Press A to return the second hand to . Press B to restore the time and time-time indicators. 4. Put the watch back to actual time and bring the crown back to position 1.

Chronograph Stopwatch OS20 / FS00

STOPWATCH SECOND HAND

Set Time 1. Pull the crown out to position 3. Stopwatch second hand will return to . Do not place the crown back in position 1 while the hands return to .---/---"-- or else the position where the hands are at the time that is done becomes recognized as the new . 2. Turn the crown to set the desired time. 3. Replace the crown in position 1.

24 HOUR GUIDE

STOPWATCH MINUTE HAND

SECOND HAND

Set Date 1. Pull the crown out to position 2. 2. Turn the crown counterclockwise until the right time is displayed in the date window. 3. Replace the crown in position 1.

Stopwatch Zero Reset This procedure shall be performed when the stopwatch second hand does not return to the . 1. Pull the crown out to position 3. 2. Press A to set the second hand of stopwatch at the . Note: The hands move quickly when the buttons remain pressed. 3. Once the pointer is set to zero, reset time and place the crown in position 1. Do not put the crown back in position 1 while the hands return to . By doing this, the position of the hands will be recognized as the new .

Operation of the Stopwatch This stopwatch is able to measure and display time in 1/1 seconds up to a maximum of 1 hour. 1. Press A to start or stop the stopwatch. 2. Press B to reset the stopwatch.

- 1 5 -

Page 16 of the Fossil FO-001 user manual — STOPWATCH MINUTE HAND
Page 16 · click to enlarge
Page 16

Chronograph Stopwatch VD54 (date - VD53)

24-HOUR STOPWATCH MINUTE HAND

Time and Date Setup 1. Before the time is set, the chronograph must be stopped and placed at zero- (12:00) position. 2. Pull the crown out to position 2. 3. Turn the crown clockwise until the date of the previous day is displayed. 4. Pull the crown to position 3 when the second hand is at 12:00-hour position. 5. Turn the crown to set time. NOTE: The 24-hour hand moves along with the hour and minute hands. When setting the time, check that the 24-hour hand is set correctly. 6. Press the crown back to position 1. NOTE: If the crown is in position 2, do not press the pushbuttons. Otherwise the chronograph hand will be turned.

STOPWATCH SECOND HAND

Chronograph 1. Press A to start/stop the chronograph. 2. Press B to reset to zero.

Interval 1. Press B while the chronograph is running. 2. Press B again to return to the chronograph. 3. Press A to end the timekeeping. 4. Press B to reset.

Chronograph Reset to Zero 1. If one of the chronograph guides is not at zero-(12.00) position, pull out the crown to position 3. 2. Press A to turn the hands clockwise; press B to turn in the dials counterclockwise. 3. Press the crown back to position 1.

Chronograph Stopwatch VD55B / VD57B

STOPWATCH 1/10

SECONDHAND

Set Time 1. Pull the crown out to position 3. 2. Turn the crown clockwise to set time. 3. Return to position 1 and start the watch.

STOPWATCH MINUTE HAND

STOPWATCH SECOND HAND

Use Stopwatch 1. Press A to start/stop the stopwatch. 2. Press B to control the interval and restore.

Manual Update Stopwatch 1. Pull the crown out to position 3. 2. Press A to return the stopwatch-1/10 second hand to the . 3. Press B to restore the second and minute hand. The hands only turn clockwise. 4. Every time pressed on A or B, the hands move one position. They move fast when the buttons are held down.

Set date (only on some models) 1. Pull the crown out to position 2. 2. Turn clockwise until desired date appears in the window. 3. Press the crown back to position 1.

- 1 6 -

Page 17 of the Fossil FO-001 user manual — SECONDSHAND
Page 17 · click to enlarge
Page 17

Chronograph stopwatch YM91

SECONDSHAND

CHRONOGRAPH

1 2 B A

Set time and date 1. Pull the crown out to position 2. 2. Turn the crown to set the desired time. 3. Turn the crown back to position 1.

HOUR HAND

MINUTEHAND

Use the stopwatch 1. Press A to start/stop the chronograph. 2. Press B to reset.

SECONDSHAND

MINUTEHAND

CHRONOGRAPH

Manual adjustment stopwatch 1. Pull the crown out to position 2. 2. Hold the left button for 2 seconds to rotate the stopwatch whole and move in position. Press the right button repeatedly to put it in the . 3. Hold the left button for 2 seconds to rotate and position the 1/5 second hand of the stopwatch completely. Press the right button repeatedly to put it in the . 4. Turn the crown back to position 1.

- 1 7 -

Page 18 of the Fossil FO-001 user manual — C B
Page 18 · click to enlarge
Page 18

DIGITAL

Digital MLL-004

Normal Time View 1. Press A to display month/date for 3 seconds. 2. Press A (or once the date is shown) twice to show seconds. Press A again to return to Normal Time View.

Time and Date Setup 1. From Normal Time View, press B twice to go into setting mode; month will be displayed. 2. Press A to increase the value. 3. Press B to set and continue to the next setting. 4. The order of settings is: month, date, hour, minute. 5. Press B to exit the settings; press A to activate the watch. Note: In Normal Time Display, the colon flashes between hours and minutes to indicate that the watch is switched on.

Digital MLL-020

Normal Time View 1. Press A to go to stopwatch mode. 2. Press B for electroluminescent. 3. Press C and hold it to display the date. 4. Press C and hold it down, then press D to switch between month/date format. 5. Press D and hold it to show the alarm time. 6. Press C and hold it down, then press A to switch between 12-/24-hour format. N.B.: In configuration mode anywhere, press A to exit setting mode.

C B

D A

Time and Calendar Settings 1. Press A and hold it for 3 seconds in normal time view, then press again on A; Tuesday display and seconds digits will blink. 2. Press D to set seconds to zero. 3. Press C to continue to minute. 4. Press D to increase the number; press D and hold it down to quickly raise ler. 5. Press C to go to the next setting value. 6. The order of settings is: seconds, minute, hour, month, date, day of the week. 7. Press A to exit the settings.

Alarm mode 1. In normal time display, press D and hold this entry, then press C to make the choice between on/off alarms. 2. The alarm will go off at a preset time for 30 seconds; press D to turn the alarm off. 3. To test the alarm, press C and D simultaneously, and hold it down. The alarm will beep.

Alarm Setup 1. In normal time display press A and hold it for 3 seconds; Monday indication and hour will begin to blink. 2. Press D to increase the number; press D and hold it down to raise faster. 3. Press C to set and continue to minute. 4. Press D to increase the number; press D and hold it down to raise faster. 5. Press A to exit the settings.

Stopwatch mode 1. Press A to go to stopwatch mode. 2. Press C to start or stop the stopwatch. 3. Press D to return to zero.

Interval 1. Press D while the stopwatch runs to determine the interval. 2. Press D again to return to the stopwatch. 3. Repeat steps 1 and 2 to measure multiple intervals. 4. Press C to stop recording time. 5. Press D to return to zero.

- 1 8 -

Page 19 of the Fossil FO-001 user manual — Digital MLG-017
Page 19 · click to enlarge
Page 19

Digital MLG-017

Normal Time View 1. Press A to change the mode. The order of settings is: normal time, alarm, time zone 2, timer, stopwatch. 2. Press B for electroluminescent. N.B.: In configuration mode, you can press D to exit settings mode anywhere. Note: In all setting modes, when no button is pressed for 2 minutes, all changes will be saved and the setting automatically jump back to view mode.

Time and Calendar Settings 1. Press D at normal time display; seconds will blink. 2. Press C to set seconds to zero. 3. Press "A" to continue to hour. 4. Press C to increase the number, press C and hold it down to raise faster. 5. Press A to set and then continue to the next setting value. 6. The order of settings is: seconds, hours, minutes, years, months, dates. 7. Press D to exit the settings. Note: The day of the week will be automatically updated when leaving settings. Note: At any time in the Time/calendar Settings mode you can press B to choose between 12/4 hour format.

Alarm mode 1. Press "A" to go into alarm mode. 2. Press D to turn the alarm/signal on or off.

Alarm Setup 1. Press "A" to go into alarm mode. 2. Press C and hold it to go to setting mode; hour will blink. 3. Press C to increase the number, press C and hold it down to raise faster. 4. Press A to set and continue to the next setting value. 5. The order of settings is: hour, minutes, month, date. For daily alarm you leave month and date set to . 6. Press D to exit the settings.

Time zone 2 1. Press A to switch to time zone 2. Note: In the display of time zone 2, normal time is shown in the lower part of the screen. 2. Press C and hold it to go to setting mode; hour will start blinking. 3. Press C to increase the number, press C and hold it down to raise faster. 4. Press A to set and continue to minutes. 5. Press C to increase the number, press C and hold it down to quickly raise ler. 6. Press D to exit the settings. Note: At any time in Time Zone 2 setting mode you can press B to choose between 12/4 hour format.

Timer 1. Press A to go to timer mode. 2. Press C to start or stop the stopwatch. 3. Press B to stop the countdown and reset timer.

Set Timer 1. Press D and hold it to go to setting mode; hour will start blinking. 2. Press C to increase the number, press C and hold it down to raise faster. 3. Press A to set and continue to the next setting value. 4. The order of settings is: hour, minutes, seconds. 5. Press D to exit setting mode. N.B.: At any time in setting mode you can press B to choose between automatically reset on/off. When automatically reset is enabled, the timer will restart automatically when it comes to zero.

Stopwatch mode 1. Press A to go to stopwatch mode. 2. Press C to start or stop the stopwatch. 3. Press B to return to zero.

Interval 1. Press B while the stopwatch runs to determine the interval. 2. Press B again to return to the stopwatch. 3. Press C to stop recording time. 4. Press B to return to zero.

- 1 9 -

Page 20 of the Fossil FO-001 user manual — Digital BJ2635
Page 20 · click to enlarge
Page 20

Digital BJ2635

Normal Time View 1. Press A to change the mode. The order of the settings is normal time display, worldtime, alarm, stopwatch, reminder mode, and timer 2. Press B for electroluminescent. 3. Press C to switch the signal on or off. 4. Press D to switch on or off summer time. Note: In each mode, when no button is pressed for 60 seconds, the setting will be automatically reset to normal time view. N.B.: Everywhere in configuration mode, press B to exit the settings mode and return to normal time view.

Alarm mode 1. Press "A" to go into alarm mode. 2. Press C to select alarms 1-3. 3. Press D to turn the alarm on or off. Note: The alarm will go off for 30 seconds immediately. Press any button to disable the alarm.

Time and Calendar Settings 1. Press D at normal time displays and hold it down; 12/4 hour format will blink. 2. Press C or D to increase or lower the number, press C or d and hold it down to increase/decrease faster. 3. Press A to continue with the next setting value. 4. The order of settings is 12/4 hour format, seconds, minutes, hours, years, months, dates, time zone. 5. Press B button to exit setting mode. Note: The day of the week will be automatically updated when leaving settings.

Alarm Setup 1. In alarm mode press C to select alarm 1, 2 or 3. 2. Pressure and hold B; minutes will start blinking. 3. Press C or D to increase or lower the number, press C or d and hold it down to increase/decrease faster. 4. Press A to continue with the next setting value. 5. The sequence of settings is minutes, hours. 6. Press B to exit setting mode.

World Time Mode 1. Press A to go into world time mode. 2. Press C to go into the next city; press C and hold it in order to increase faster. 3. Press D to switch the summer time on or off depending on the city's time zone you are currently in.

Stopwatch mode 1. Press A to go to stopwatch mode. 2. Press C to start the stopwatch; on D to stop it. 3. Press D to return to zero.

Diagram . .
Diagram . .

Round time 1. Press C while the stopwatch runs to determine round time. The screen will display the round time for 5 seconds, where it will return to stopwatch time. 2. Press C again to measure multiple lap times (up to 99 rounds). 3. Press D to stop recording time. The screen will display the current round time for 5 seconds, after which the total time will be displayed. 4. Press D again to set back to zero.

Reminder Mode 1. Press A to go to the memory mode. Total time will be displayed. Note: If no data is stored then pressing A will cause a stopwatch mode to switch to timer mode. 2. Press C to view the following data; press D to view previous data (memory saves up to 20 rounds, round 1 - round 19, and last lap).

Timer 1. Press A to go to timer mode. 2. Press C to start or stop the stopwatch. 3. Press D to restore the timer on preset value. Note: When the timer reaches zero or a preset value, the alarm will go off for 30 seconds. Press any button to turn off the alarm.

Set Timer 1. Press D and hold it in timer mode; seconds will blink. 2. Press C or D to increase or lower the number, press C or d and hold it down to increase/decrease faster. 3. Press A to continue with the next setting value. 4. The order of settings is: seconds, minutes, hours. 5. Press B to exit setting mode.

- 2 0 -

Page 21 of the Fossil FO-001 user manual — Scrolling Tic
Page 21 · click to enlarge
Page 21

Digital FL145 / FL186

Normal Time View 1. Press A to change the mode. 2. Press B for electroluminescent. 3. Press C to switch between the 12/4 hour format. 4. Press D to stop the alarm noise.

Time and Calendar Settings 1. Press A three times in normal time view to go into setting mode. Seconds will blink. 2. Press C to set seconds back to zero. 3. Press D to set and proceed to the next setting value. 4. Press C to increase the number, press C and hold it down to raise faster. Press D to set each setting value. 5. The order of settings is: seconds, hours, minutes, month, date, day of the week. 6. Press A to exit setting mode.

Alarm Setup 1. Press A to go to Al. 2. Press and hold C to test the alarm sound. 3. Press C to switch between alarm/signal on/off. 4. Press and hold D to go to setting mode; hour will start blinking. 5. Press C to increase the number, press and hold C to raise quickly. 6. Press D to set hours and minutes. 7. Count mode will be automatically abandoned after the minutes are set.

Stopwatch mode 1. Press A to go to stopwatch mode (ST). 2. Press C to start or stop the stopwatch. 3. Press the D button to reset stopwatch when it is not running.

Interval 1. Press D while the stopwatch is running. 2. Press D again to return to the stopwatch. 3. Press C to stop recording time. 4. Press D to return to zero.

Digital FO-001

Normal Time View Press A to change view. Display sequence is normal time, date, seconds.

Set Time and Calendar 1. In normal time display, press B twice; month starts blinking. 2. Press A to increase numbers. 3. Press B to continue with the next setting value. 4. Setting sequence is: month, date, hour and minute. 5. Press B to exit setting mode. NOTE: At any time, in setting mode, you can press A to exit the setup mode and go back to normal time view.

Scrolling Tic

Time setting 1. Pull the crown out to position 2. 2. Turn the crown to set the time you want. 3. Bring the crown back to position 1.

View Options Press A to navigate between different view choices.

The seconds are displayed from .a.01.b. to .60.b in different display options.

- 2 1 -

Page 22 of the Fossil FO-001 user manual — LED QFL558FA
Page 22 · click to enlarge
Page 22

LED QFL558FA

Hour/Minute Display 1. Press A to turn on/off view. NOTE: Time/Minur Display is the default display when the display is enabled. 2. Press B to enable hour/minute view and seconds display.

Seconds View Press A or B to return to hour/minute view.

Time setting 1. In Hour/Minute Display, press B and hold it to access the setting module; hour will flicker once. 2. Press A to increase numbers. 3. Press B to continue to the minutes. 4. Press A to increase numbers. 5. Press B and keep it pressed to leave the setting module. Hour and minutes will flicker once. NOTE: If no button is used for 10 seconds, all changes will be saved in the setting module and the settings will automatically be reset to Hour/Minute Display mode.

- 2 2 -

Page 23 of the Fossil FO-001 user manual — OTHER
Page 23 · click to enlarge
Page 23

OTHER

Diagram . .
Diagram . .

Always set the crown in closed position (normal position). Tighten the screw lock completely.

  • To ensure water resistance, exposure to hot water is not recommended.
  • Clean your watch with a soft cloth and water. Do not immerse your watch in water unless it is waterproof (see rear of the housing).
  • After using salt water, rinse your watch under the boulder and dry with a soft cloth.
  • Metal watch straps need to be cleaned occasionally in order to keep them beautiful. Cleaning with a soft brush soaked in a mild soup. Make sure you dry the watch thoroughly with a soft cloth.

- 2 3 -

Ask about the Fossil FO-001

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Fossil FO-001

Be the first to ask — other owners or our team will answer.

Original document

Fossil FO-001 manual PDF

23 pages·2.2 MB·Watch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…