EN
Flir logo
Official user manual

Flir T1020

276 pages·27.7 MB·Photo Camera·PDF·ENDEFRITNLJA
Flir T1020
Table of Contents 342 sections 1 Disclaimers · 1.1 Legal disclaimer · 1.2 Usage statistics · 1.3 Changes to registry · … ShowHide
1 Disclaimersp.151.1 Legal disclaimerp.151.2 Usage statisticsp.151.3 Changes to registryp.151.4 U.S. Government Regulationsp.161.5 Copyrightp.161.6 Quality assurancep.161.7 Patentsp.161.8 Third-party licensesp.171.8.1 GNU Lesser General Public License (LGPL)p.171.8.2 Fonts (Source Han Sans)p.171.8.3 Fonts (DejaVu)p.172 Safety informationp.183 Notice to userp.233.1 User-to-user forumsp.233.2 Calibrationp.233.3 Accuracyp.233.4 Disposal of electronic wastep.233.5 Trainingp.233.6 Documentation updatesp.233.7 Important note about this manualp.233.8 Note about authoritative versionsp.244 Customer helpp.254.1 Generalp.254.2 Submitting a questionp.254.3 Downloadsp.265 Introductionp.275.1 General descriptionp.275.2 Key benefitsp.276 Quick start guidep.286.1 Procedurep.287 About FLIR Tools/Tools+p.297.1 Introductionp.297.2 Workflowp.307.2.1 Generalp.307.2.2 Figurep.307.2.3 Explanationp.308 Using the high-speed interface (HSI)p.318.1 Generalp.318.2 System overviewp.318.2.1 Figurep.318.2.2 Explanationp.318.3 Quick start guidep.328.4 HSI box indicator LEDp.328.5 Digital I/Op.329 A note about ergonomicsp.339.1 Generalp.339.2 Figurep.3310 Camera partsp.3410.1 View from the rightp.3410.1.1 Figurep.3410.1.2 Explanationp.3410.2 View from the leftp.3510.2.1 Figurep.3510.2.2 Explanationp.3510.3 View from the bottomp.3610.3.1 Figurep.3610.3.2 Explanationp.3610.4 View from the rearp.3710.4.1 Figurep.3710.4.2 Explanationp.3710.5 Neck strap attachment pointsp.3910.5.1 Figurep.3910.6 Battery condition LED indicatorp.3910.6.1 Figurep.3910.6.2 Explanationp.3910.7 Power LED indicatorp.4010.7.1 Figurep.4010.7.2 Explanationp.4010.8 Laser pointerp.4010.8.1 Figurep.4010.8.2 Laser warning labelp.4110.8.3 Laser rules and regulationsp.4111 Screen elementsp.4211.1 Figurep.4211.2 Explanationp.4211.3 Status icons and indicatorsp.4211.4 Image overlay informationp.4312 Navigating the menu systemp.4412.1 Generalp.4412.2 Navigating using the joystickp.4413 Handling the camerap.4513.1 Charging the batteryp.4513.1.1 Using the power supply to charge the batteryp.4513.1.2 Using the stand-alone battery charger to charge the batteryp.4513.2 Turning on the camerap.4513.2.1 Procedurep.4513.3 Turning off the camerap.4513.3.1 Procedurep.4513.4 Adjusting the viewfinder’s dioptric correction (sharpness)p.4613.4.1 Figurep.4613.4.2 Procedurep.4613.5 Adjusting the angle of the lensp.4713.5.1 Figurep.4713.6 Adjusting the infrared camera focus manuallyp.4713.6.1 Figurep.4713.6.2 Procedurep.4713.7 Autofocusing the infrared camerap.4813.7.1 Generalp.4813.7.2 Figurep.4813.7.3 Procedurep.4813.8 Continuous autofocusp.4913.8.1 Generalp.4913.8.2 Procedurep.4913.9 Operating the laser pointerp.4913.9.1 Figurep.5013.9.2 Procedurep.5013.10 Using the digital zoom functionp.5013.10.1 Generalp.5013.10.2 Figurep.5113.10.3 Procedurep.5113.11 Assigning functions to the programmable buttonsp.5113.11.1 Generalp.5113.11.2 Procedurep.5213.12 Using the camera lamp as a flashp.5213.12.1 Generalp.5213.12.2 Procedurep.5213.13 Changing lensesp.5213.14 Using the close-up lensp.5613.14.1 Generalp.5613.14.2 Attaching the close-up lensp.5613.14.3 Removing the close-up lensp.5813.15 Calibrating the compassp.6013.15.1 Procedurep.6014 Saving and working with imagesp.6114.1 About image filesp.6114.1.1 Generalp.6114.1.2 File-naming conventionp.6114.1.3 Image capacityp.6114.1.4 About UltraMaxp.6114.2 Saving an imagep.6114.2.1 Generalp.6114.2.2 Procedurep.6214.3 Previewing an imagep.6214.3.1 Generalp.6214.3.2 Procedurep.6214.4 Opening a saved imagep.6214.4.1 Generalp.6214.4.2 Procedurep.6214.5 Editing a saved imagep.6314.5.1 Generalp.6314.5.2 Procedurep.6314.5.3 Related topicsp.6314.6 Creating a PDF report in the camerap.6314.6.1 Generalp.6314.6.2 Naming conventionp.6414.6.3 Procedurep.6414.7 Deleting an imagep.6414.7.1 Generalp.6414.7.2 Procedurep.6414.8 Deleting multiple imagesp.6414.8.1 Generalp.6414.8.2 Procedurep.6414.9 Deleting all imagesp.6514.9.1 Generalp.6514.9.2 Procedurep.6514.10 Resetting the image counterp.6514.10.1 Generalp.6514.10.2 Procedurep.6515 Achieving a good imagep.6715.1 Generalp.6715.2 Adjusting the infrared camera focusp.6715.3 Adjusting the infrared imagep.6715.3.1 Generalp.6715.3.2 Example 1p.6815.3.3 Example 2p.6815.3.4 Manual adjustment in Level, Span modep.6915.3.5 Manual adjustment in Level, Max, Min modep.6915.4 Changing the temperature rangep.6915.4.1 Generalp.6915.4.2 Procedurep.6915.5 Changing the color palettep.7015.5.1 Generalp.7015.5.2 Procedurep.7115.6 Changing the object parametersp.7115.7 Calibrating the camerap.7215.7.1 Generalp.7215.7.2 Manual calibrationp.7215.8 Hiding all overlayp.7215.8.1 Generalp.7215.8.2 Procedurep.7316 Working with image modesp.7416.1 Generalp.7416.2 Image examplesp.7416.3 Selecting the image modep.7517 Working with measurement toolsp.7617.1 Generalp.7617.2 Adding/removing measurement toolsp.7617.3 Working with user presetsp.7617.3.1 Generalp.7617.3.2 Procedurep.7617.4 Resizing or moving a measurement toolp.7717.4.1 Generalp.7717.4.2 Procedurep.7717.5 Changing object parametersp.7817.5.1 Generalp.7817.5.2 Types of parametersp.7817.5.3 Recommended valuesp.7917.5.4 Procedurep.7917.5.5 Related topicsp.8017.6 Displaying values in the result table and displaying a graphp.8017.6.1 Generalp.8017.6.2 Procedurep.8117.7 Creating and setting up a difference calculationp.8117.7.1 Generalp.8117.7.2 Procedurep.8117.8 Setting a measurement alarmp.8217.8.1 Generalp.8217.8.2 Types of alarmp.8217.8.3 Alarm signalsp.8217.8.4 Procedurep.8318 Working with color alarms and isothermsp.8518.1 Color alarmsp.8518.1.1 Generalp.8518.1.2 Image examplesp.8518.2 Setting up above, below, and interval alarmsp.8618.3 Building isothermsp.8718.3.1 About the Condensation alarmp.8718.3.2 About the Insulation alarmp.8718.3.3 Setting up condensation and insulation alarmsp.8719 Annotating imagesp.8819.1 Generalp.8819.2 Adding a notep.8819.2.1 Generalp.8819.2.2 Procedurep.8819.3 Adding a tablep.8819.3.1 Generalp.8819.3.2 Procedurep.8919.4 Adding a voice annotationp.8919.4.1 Generalp.8919.4.2 Procedurep.9019.5 Adding a sketchp.9019.5.1 Generalp.9019.5.2 Procedurep.9020 Programming the camera (time lapse)p.9220.1 Generalp.9220.2 Procedurep.9221 Recording video clipsp.9321.1 Generalp.9321.2 Procedurep.9322 Screening alarmp.9422.1 Generalp.9422.2 Procedurep.9423 Pairing Bluetooth devicesp.9523.1 Generalp.9523.2 Procedurep.9524 Configuring Wi-Fip.9624.1 Generalp.9624.2 Setting up a wireless access point (most common use)p.9624.3 Connecting the camera to a WLAN (less common use)p.9625 Changing settingsp.9725.1 Generalp.9725.1.1 Define user presetsp.9725.1.2 Camera temperature rangep.9725.1.3 Save options & storagep.9725.1.4 Programmable buttonsp.9825.1.5 Device settingsp.9925.2 Procedurep.10126 Technical datap.10226.1 Online field-of-view calculatorp.10226.2 Note about technical datap.10226.3 Note about authoritative versionsp.10226.4 FLIR T1020 12°p.10326.5 FLIR T1020 28°p.11026.6 FLIR T1020 45°p.11726.7 FLIR T1020 28° and 12°p.12426.8 FLIR T1020 28° and 45°p.13126.9 FLIR T1020 28°, 12°, and 45°p.13826.10 FLIR T1030sc 12°p.14526.11 FLIR T1030sc 28°p.15226.12 FLIR T1030sc 45°p.15926.13 FLIR T1040 12°p.16626.14 FLIR T1040 28°p.17326.15 FLIR T1040 45°p.18026.16 FLIR T1050sc 12°p.18726.17 FLIR T1050sc 28°p.19426.18 FLIR T1050sc 45°p.20126.19 IR lens, f=36 mm (28°) with casep.20826.20 Close-up lens 3× (51 µm) with casep.21026.21 IR lens f=21.2 mm (45°) with casep.21126.22 IR lens f=83.4 mm (12°) with casep.21326.23 FLIR T10xx SC kitp.21527 Mechanical drawingsp.21728 Digital I/O pin configurationp.22528.1 Pin configuration for the Digital I/O connector on the HSI boxp.22529 Digital I/O connection diagramp.22630 CE Declaration of conformityp.22831 Cleaning the camerap.23031.1 Camera housing, cables, and other itemsp.23031.1.1 Liquidsp.23031.1.2 Equipmentp.23031.1.3 Procedurep.23031.2 Infrared lensp.23031.2.1 Liquidsp.23031.2.2 Equipmentp.23031.2.3 Procedurep.23031.3 Infrared detectorp.23131.3.1 Generalp.23131.3.2 Procedurep.23132 Application examplesp.23232.1 Moisture & water damagep.23232.1.1 Generalp.23232.1.2 Figurep.23232.2 Faulty contact in socketp.23232.2.1 Generalp.23232.2.2 Figurep.23332.3 Oxidized socketp.23332.3.1 Generalp.23332.3.2 Figurep.23332.4 Insulation deficienciesp.23432.4.1 Generalp.23432.4.2 Figurep.23432.5 Draftp.23532.5.1 Generalp.23532.5.2 Figurep.23533 About FLIR Systemsp.23733.1 More than just an infrared camerap.23833.2 Sharing our knowledgep.23833.3 Supporting our customersp.23934 Glossaryp.24035 Thermographic measurement techniquesp.24335.1 Introductionp.24335.2 Emissivityp.24335.2.1 Finding the emissivity of a samplep.24335.3 Reflected apparent temperaturep.24735.4 Distancep.24735.5 Relative humidityp.24735.6 Other parametersp.24736 History of infrared technologyp.24837 Theory of thermographyp.25137.1 Introductionp.25137.2 The electromagnetic spectrump.25137.3 Blackbody radiationp.25137.3.1 Planck’s lawp.25237.3.2 Wien’s displacement lawp.25337.3.3 Stefan-Boltzmann's lawp.25437.3.4 Non-blackbody emittersp.25537.4 Infrared semi-transparent materialsp.25738 The measurement formulap.25839 Emissivity tablesp.26239.1 Referencesp.26239.2 Tablesp.262
Page 1 of the Flir T1020 user manual — User’s manual FLIR T10xx series
Page 1 · click to enlarge
Page 1

User’s manual FLIR T10xx series

Flir T1020 — User’s manual FLIR T10xx series diagram (page 1)
Fig. 1 · User’s manual FLIR T10xx series
Page 2 of the Flir T1020 user manual
Page 2 · click to enlarge
Page 2
Page 2 of the Flir T1020 user manual
Page 3 of the Flir T1020 user manual
Page 3 · click to enlarge
Page 3
Page 3 of the Flir T1020 user manual
Page 4 of the Flir T1020 user manual — 重要注意事项 在操作设备之前,您必须阅读、理解并遵循所有说明、警告、注意事项和法律免责声明。
Page 4 · click to enlarge
Page 4

Důležitá poznámka Před použitím zařízení si přečtěte veškeré pokyny, upozornění, varování a vyvázání se ze záruky, ujistěte se, že jim rozumíte, a řiďte se jimi.

Vigtig meddelelse Før du betjener enheden, skal du du læse, forstå og følge alle anvisninger, advarsler, sikkerhedsforanstaltninger og ansvarsfraskrivelser.

Σημαντική σημείωση Πριν από τη λειτουργία της συσκευής, πρέπει να διαβάσετε, να κατανοήσετε και να ακολουθήσετε όλες τις οδηγίες, προειδοποιήσεις, προφυλάξεις και νομικές αποποιήσεις.

Tärkeä huomautus Ennen laitteen käyttämistä on luettava ja ymmärrettävä kaikki ohjeet, vakavat varoitukset, varoitukset ja lakitiedotteet sekä noudatettava niitä.

Fontos megjegyzés Az eszköz használata előtt figyelmesen olvassa el és tartsa be az összes utasítást, figyelmeztetést, óvintézkedést és jogi nyilatkozatot.

重要な注意 デバイスをご使用になる前に、あらゆる指示、警告、注意事項、および免責条項をお読み頂き、その内容を理解して従ってください。

중요한참고사항 장치를작동하기전에반드시다음의사용설명서와경고, 주의사항, 법적책임제한을읽고이해하며따라야합니다.

Viktig Før du bruker enheten, må du lese, forstå og følge instruksjoner, advarsler og informasjon om ansvarsfraskrivelse.

Ważna uwaga Przed rozpoczęciem korzystania z urządzenia należy koniecznie zapoznać się z wszystkimi instrukcjami, ostrzeżeniami, przestrogami i uwagami prawnymi. Należy zawsze postępować zgodnie z zaleceniami tam zawartymi.

Важное примечание До того, как пользоваться устройством, вам необходимо прочитать и понять все предупреждения, предостережения и юридические ограничения ответственности и следовать им.

Viktig information Innan du använder enheten måste du läsa, förstå och följa alla anvisningar, varningar, försiktighetsåtgärder och ansvarsfriskrivningar.

Önemli not Cihazı çalıştırmadan önce tüm talimatları, uyarıları, ikazları ve yasal açıklamaları okumalı, anlamalı ve bunlara uymalısınız.

重要注意事项 在操作设备之前,您必须阅读、理解并遵循所有说明、警告、注意事项和法律免责声明。

重要注意事項 操作裝置之前,您務必閱讀、了解並遵循所有說明、警告、注意事項與法律免責聲明。

Page 5 of the Flir T1020 user manual — User’s manual FLIR T10xx series
Page 5 · click to enlarge
Page 5

User’s manual FLIR T10xx series

#T559954; r. AL/37426/37426; en-US v

Page 6 of the Flir T1020 user manual
Page 6 · click to enlarge
Page 6
Page 6 of the Flir T1020 user manual
Page 7 of the Flir T1020 user manual — Table of contents
Page 7 · click to enlarge
Page 7

Table of contents

1 Disclaimersp.151.1 Legal disclaimerp.151.2 Usage statisticsp.151.3 Changes to registryp.151.4 U.S. Government Regulationsp.161.5 Copyrightp.161.6 Quality assurancep.161.7 Patentsp.161.8 Third-party licensesp.171.8.1 GNU Lesser General Public License (LGPL)p.171.8.2 Fonts (Source Han Sans)p.171.8.3 Fonts (DejaVu)p.172 Safety informationp.183 Notice to userp.233.1 User-to-user forumsp.233.2 Calibrationp.233.3 Accuracyp.233.4 Disposal of electronic wastep.233.5 Trainingp.233.6 Documentation updatesp.233.7 Important note about this manualp.233.8 Note about authoritative versionsp.244 Customer helpp.254.1 Generalp.254.2 Submitting a questionp.254.3 Downloadsp.265 Introductionp.275.1 General descriptionp.275.2 Key benefitsp.276 Quick start guidep.286.1 Procedurep.287 About FLIR Tools/Tools+p.297.1 Introductionp.297.2 Workflowp.307.2.1 Generalp.307.2.2 Figurep.307.2.3 Explanationp.308 Using the high-speed interface (HSI)p.318.1 Generalp.318.2 System overviewp.318.2.1 Figurep.318.2.2 Explanationp.318.3 Quick start guidep.328.4 HSI box indicator LEDp.328.5 Digital I/Op.329 A note about ergonomicsp.339.1 Generalp.339.2 Figurep.3310 Camera partsp.3410.1 View from the rightp.3410.1.1 Figurep.3410.1.2 Explanationp.3410.2 View from the leftp.3510.2.1 Figurep.3510.2.2 Explanationp.3510.3 View from the bottomp.3610.3.1 Figurep.3610.3.2 Explanationp.3610.4 View from the rearp.3710.4.1 Figurep.3710.4.2 Explanationp.3710.5 Neck strap attachment pointsp.3910.5.1 Figurep.3910.6 Battery condition LED indicatorp.3910.6.1 Figurep.3910.6.2 Explanationp.3910.7 Power LED indicatorp.4010.7.1 Figurep.4010.7.2 Explanationp.4010.8 Laser pointerp.4010.8.1 Figurep.4010.8.2 Laser warning labelp.4110.8.3 Laser rules and regulationsp.4111 Screen elementsp.4211.1 Figurep.4211.2 Explanationp.4211.3 Status icons and indicatorsp.4211.4 Image overlay informationp.4312 Navigating the menu systemp.4412.1 Generalp.4412.2 Navigating using the joystickp.4413 Handling the camerap.4513.1 Charging the batteryp.4513.1.1 Using the power supply to charge the batteryp.4513.1.2 Using the stand-alone battery charger to charge the batteryp.4513.2 Turning on the camerap.4513.2.1 Procedurep.4513.3 Turning off the camerap.4513.3.1 Procedurep.4513.4 Adjusting the viewfinder’s dioptric correction (sharpness)p.4613.4.1 Figurep.4613.4.2 Procedurep.4613.5 Adjusting the angle of the lensp.4713.5.1 Figurep.4713.6 Adjusting the infrared camera focus manuallyp.4713.6.1 Figurep.4713.6.2 Procedurep.4713.7 Autofocusing the infrared camerap.4813.7.1 Generalp.4813.7.2 Figurep.4813.7.3 Procedurep.4813.8 Continuous autofocusp.4913.8.1 Generalp.4913.8.2 Procedurep.4913.9 Operating the laser pointerp.4913.9.1 Figurep.5013.9.2 Procedurep.5013.10 Using the digital zoom functionp.5013.10.1 Generalp.5013.10.2 Figurep.5113.10.3 Procedurep.5113.11 Assigning functions to the programmable buttonsp.5113.11.1 Generalp.5113.11.2 Procedurep.5213.12 Using the camera lamp as a flashp.5213.12.1 Generalp.5213.12.2 Procedurep.5213.13 Changing lensesp.5213.14 Using the close-up lensp.5613.14.1 Generalp.5613.14.2 Attaching the close-up lensp.5613.14.3 Removing the close-up lensp.5813.15 Calibrating the compassp.6013.15.1 Procedurep.6014 Saving and working with imagesp.6114.1 About image filesp.6114.1.1 Generalp.6114.1.2 File-naming conventionp.6114.1.3 Image capacityp.6114.1.4 About UltraMaxp.6114.2 Saving an imagep.6114.2.1 Generalp.6114.2.2 Procedurep.6214.3 Previewing an imagep.6214.3.1 Generalp.6214.3.2 Procedurep.6214.4 Opening a saved imagep.6214.4.1 Generalp.6214.4.2 Procedurep.6214.5 Editing a saved imagep.6314.5.1 Generalp.6314.5.2 Procedurep.6314.5.3 Related topicsp.6314.6 Creating a PDF report in the camerap.6314.6.1 Generalp.6314.6.2 Naming conventionp.6414.6.3 Procedurep.6414.7 Deleting an imagep.6414.7.1 Generalp.6414.7.2 Procedurep.6414.8 Deleting multiple imagesp.6414.8.1 Generalp.6414.8.2 Procedurep.6414.9 Deleting all imagesp.6514.9.1 Generalp.6514.9.2 Procedurep.6514.10 Resetting the image counterp.6514.10.1 Generalp.6514.10.2 Procedurep.6515 Achieving a good imagep.6715.1 Generalp.6715.2 Adjusting the infrared camera focusp.6715.3 Adjusting the infrared imagep.6715.3.1 Generalp.6715.3.2 Example 1p.6815.3.3 Example 2p.6815.3.4 Manual adjustment in Level, Span modep.6915.3.5 Manual adjustment in Level, Max, Min modep.6915.4 Changing the temperature rangep.6915.4.1 Generalp.6915.4.2 Procedurep.6915.5 Changing the color palettep.7015.5.1 Generalp.7015.5.2 Procedurep.7115.6 Changing the object parametersp.7115.7 Calibrating the camerap.7215.7.1 Generalp.7215.7.2 Manual calibrationp.7215.8 Hiding all overlayp.7215.8.1 Generalp.7215.8.2 Procedurep.7316 Working with image modesp.7416.1 Generalp.7416.2 Image examplesp.7416.3 Selecting the image modep.7517 Working with measurement toolsp.7617.1 Generalp.7617.2 Adding/removing measurement toolsp.7617.3 Working with user presetsp.7617.3.1 Generalp.7617.3.2 Procedurep.7617.4 Resizing or moving a measurement toolp.7717.4.1 Generalp.7717.4.2 Procedurep.7717.5 Changing object parametersp.7817.5.1 Generalp.7817.5.2 Types of parametersp.7817.5.3 Recommended valuesp.7917.5.4 Procedurep.7917.5.5 Related topicsp.8017.6 Displaying values in the result table and displaying a graphp.8017.6.1 Generalp.8017.6.2 Procedurep.8117.7 Creating and setting up a difference calculationp.8117.7.1 Generalp.8117.7.2 Procedurep.8117.8 Setting a measurement alarmp.8217.8.1 Generalp.8217.8.2 Types of alarmp.8217.8.3 Alarm signalsp.8217.8.4 Procedurep.8318 Working with color alarms and isothermsp.8518.1 Color alarmsp.8518.1.1 Generalp.8518.1.2 Image examplesp.8518.2 Setting up above, below, and interval alarmsp.8618.3 Building isothermsp.8718.3.1 About the Condensation alarmp.8718.3.2 About the Insulation alarmp.8718.3.3 Setting up condensation and insulation alarmsp.8719 Annotating imagesp.8819.1 Generalp.8819.2 Adding a notep.8819.2.1 Generalp.8819.2.2 Procedurep.8819.3 Adding a tablep.8819.3.1 Generalp.8819.3.2 Procedurep.8919.4 Adding a voice annotationp.8919.4.1 Generalp.8919.4.2 Procedurep.9019.5 Adding a sketchp.9019.5.1 Generalp.9019.5.2 Procedurep.9020 Programming the camera (time lapse)p.9220.1 Generalp.9220.2 Procedurep.9221 Recording video clipsp.9321.1 Generalp.9321.2 Procedurep.9322 Screening alarmp.9422.1 Generalp.9422.2 Procedurep.9423 Pairing Bluetooth devicesp.9523.1 Generalp.9523.2 Procedurep.9524 Configuring Wi-Fip.9624.1 Generalp.9624.2 Setting up a wireless access point (most common use)p.9624.3 Connecting the camera to a WLAN (less common use)p.9625 Changing settingsp.9725.1 Generalp.9725.1.1 Define user presetsp.9725.1.2 Camera temperature rangep.9725.1.3 Save options & storagep.9725.1.4 Programmable buttonsp.9825.1.5 Device settingsp.9925.2 Procedurep.10126 Technical datap.10226.1 Online field-of-view calculatorp.10226.2 Note about technical datap.10226.3 Note about authoritative versionsp.10226.4 FLIR T1020 12°p.10326.5 FLIR T1020 28°p.11026.6 FLIR T1020 45°p.11726.7 FLIR T1020 28° and 12°p.12426.8 FLIR T1020 28° and 45°p.13126.9 FLIR T1020 28°, 12°, and 45°p.13826.10 FLIR T1030sc 12°p.14526.11 FLIR T1030sc 28°p.15226.12 FLIR T1030sc 45°p.15926.13 FLIR T1040 12°p.16626.14 FLIR T1040 28°p.17326.15 FLIR T1040 45°p.18026.16 FLIR T1050sc 12°p.18726.17 FLIR T1050sc 28°p.19426.18 FLIR T1050sc 45°p.20126.19 IR lens, f=36 mm (28°) with casep.20826.20 Close-up lens 3× (51 µm) with casep.21026.21 IR lens f=21.2 mm (45°) with casep.21126.22 IR lens f=83.4 mm (12°) with casep.21326.23 FLIR T10xx SC kitp.21527 Mechanical drawingsp.21728 Digital I/O pin configurationp.22528.1 Pin configuration for the Digital I/O connector on the HSI boxp.22529 Digital I/O connection diagramp.22630 CE Declaration of conformityp.22831 Cleaning the camerap.23031.1 Camera housing, cables, and other itemsp.23031.1.1 Liquidsp.23031.1.2 Equipmentp.23031.1.3 Procedurep.23031.2 Infrared lensp.23031.2.1 Liquidsp.23031.2.2 Equipmentp.23031.2.3 Procedurep.23031.3 Infrared detectorp.23131.3.1 Generalp.23131.3.2 Procedurep.23132 Application examplesp.23232.1 Moisture & water damagep.23232.1.1 Generalp.23232.1.2 Figurep.23232.2 Faulty contact in socketp.23232.2.1 Generalp.23232.2.2 Figurep.23332.3 Oxidized socketp.23332.3.1 Generalp.23332.3.2 Figurep.23332.4 Insulation deficienciesp.23432.4.1 Generalp.23432.4.2 Figurep.23432.5 Draftp.23532.5.1 Generalp.23532.5.2 Figurep.23533 About FLIR Systemsp.23733.1 More than just an infrared camerap.23833.2 Sharing our knowledgep.23833.3 Supporting our customersp.23934 Glossaryp.24035 Thermographic measurement techniquesp.24335.1 Introductionp.24335.2 Emissivityp.24335.2.1 Finding the emissivity of a samplep.24335.3 Reflected apparent temperaturep.24735.4 Distancep.24735.5 Relative humidityp.24735.6 Other parametersp.24736 History of infrared technologyp.24837 Theory of thermographyp.25137.1 Introductionp.25137.2 The electromagnetic spectrump.25137.3 Blackbody radiationp.25137.3.1 Planck’s lawp.25237.3.2 Wien’s displacement lawp.25337.3.3 Stefan-Boltzmann's lawp.25437.3.4 Non-blackbody emittersp.25537.4 Infrared semi-transparent materialsp.25738 The measurement formulap.25839 Emissivity tablesp.26239.1 Referencesp.26239.2 Tablesp.262
Page 8 of the Flir T1020 user manual — Table of contents
Page 8 · click to enlarge
Page 8

Table of contents

1 Disclaimersp.151.1 Legal disclaimerp.151.2 Usage statisticsp.151.3 Changes to registryp.151.4 U.S. Government Regulationsp.161.5 Copyrightp.161.6 Quality assurancep.161.7 Patentsp.161.8 Third-party licensesp.171.8.1 GNU Lesser General Public License (LGPL)p.171.8.2 Fonts (Source Han Sans)p.171.8.3 Fonts (DejaVu)p.172 Safety informationp.183 Notice to userp.233.1 User-to-user forumsp.233.2 Calibrationp.233.3 Accuracyp.233.4 Disposal of electronic wastep.233.5 Trainingp.233.6 Documentation updatesp.233.7 Important note about this manualp.233.8 Note about authoritative versionsp.244 Customer helpp.254.1 Generalp.254.2 Submitting a questionp.254.3 Downloadsp.265 Introductionp.275.1 General descriptionp.275.2 Key benefitsp.276 Quick start guidep.286.1 Procedurep.287 About FLIR Tools/Tools+p.297.1 Introductionp.297.2 Workflowp.307.2.1 Generalp.307.2.2 Figurep.307.2.3 Explanationp.308 Using the high-speed interface (HSI)p.318.1 Generalp.318.2 System overviewp.318.2.1 Figurep.318.2.2 Explanationp.318.3 Quick start guidep.328.4 HSI box indicator LEDp.328.5 Digital I/Op.329 A note about ergonomicsp.339.1 Generalp.339.2 Figurep.3310 Camera partsp.3410.1 View from the rightp.3410.1.1 Figurep.3410.1.2 Explanationp.3410.2 View from the leftp.3510.2.1 Figurep.3510.2.2 Explanationp.3510.3 View from the bottomp.3610.3.1 Figurep.3610.3.2 Explanationp.3610.4 View from the rearp.3710.4.1 Figurep.3710.4.2 Explanationp.3710.5 Neck strap attachment pointsp.3910.5.1 Figurep.3910.6 Battery condition LED indicatorp.3910.6.1 Figurep.3910.6.2 Explanationp.3910.7 Power LED indicatorp.4010.7.1 Figurep.4010.7.2 Explanationp.4010.8 Laser pointerp.4010.8.1 Figurep.4010.8.2 Laser warning labelp.4110.8.3 Laser rules and regulationsp.4111 Screen elementsp.4211.1 Figurep.4211.2 Explanationp.4211.3 Status icons and indicatorsp.4211.4 Image overlay informationp.4312 Navigating the menu systemp.4412.1 Generalp.4412.2 Navigating using the joystickp.4413 Handling the camerap.4513.1 Charging the batteryp.4513.1.1 Using the power supply to charge the batteryp.4513.1.2 Using the stand-alone battery charger to charge the batteryp.4513.2 Turning on the camerap.4513.2.1 Procedurep.4513.3 Turning off the camerap.4513.3.1 Procedurep.4513.4 Adjusting the viewfinder’s dioptric correction (sharpness)p.4613.4.1 Figurep.4613.4.2 Procedurep.4613.5 Adjusting the angle of the lensp.4713.5.1 Figurep.4713.6 Adjusting the infrared camera focus manuallyp.4713.6.1 Figurep.4713.6.2 Procedurep.4713.7 Autofocusing the infrared camerap.4813.7.1 Generalp.4813.7.2 Figurep.4813.7.3 Procedurep.4813.8 Continuous autofocusp.4913.8.1 Generalp.4913.8.2 Procedurep.4913.9 Operating the laser pointerp.4913.9.1 Figurep.5013.9.2 Procedurep.5013.10 Using the digital zoom functionp.5013.10.1 Generalp.5013.10.2 Figurep.5113.10.3 Procedurep.5113.11 Assigning functions to the programmable buttonsp.5113.11.1 Generalp.5113.11.2 Procedurep.5213.12 Using the camera lamp as a flashp.5213.12.1 Generalp.5213.12.2 Procedurep.5213.13 Changing lensesp.5213.14 Using the close-up lensp.5613.14.1 Generalp.5613.14.2 Attaching the close-up lensp.5613.14.3 Removing the close-up lensp.5813.15 Calibrating the compassp.6013.15.1 Procedurep.6014 Saving and working with imagesp.6114.1 About image filesp.6114.1.1 Generalp.6114.1.2 File-naming conventionp.6114.1.3 Image capacityp.6114.1.4 About UltraMaxp.6114.2 Saving an imagep.6114.2.1 Generalp.6114.2.2 Procedurep.6214.3 Previewing an imagep.6214.3.1 Generalp.6214.3.2 Procedurep.6214.4 Opening a saved imagep.6214.4.1 Generalp.6214.4.2 Procedurep.6214.5 Editing a saved imagep.6314.5.1 Generalp.6314.5.2 Procedurep.6314.5.3 Related topicsp.6314.6 Creating a PDF report in the camerap.6314.6.1 Generalp.6314.6.2 Naming conventionp.6414.6.3 Procedurep.6414.7 Deleting an imagep.6414.7.1 Generalp.6414.7.2 Procedurep.6414.8 Deleting multiple imagesp.6414.8.1 Generalp.6414.8.2 Procedurep.6414.9 Deleting all imagesp.6514.9.1 Generalp.6514.9.2 Procedurep.6514.10 Resetting the image counterp.6514.10.1 Generalp.6514.10.2 Procedurep.6515 Achieving a good imagep.6715.1 Generalp.6715.2 Adjusting the infrared camera focusp.6715.3 Adjusting the infrared imagep.6715.3.1 Generalp.6715.3.2 Example 1p.6815.3.3 Example 2p.6815.3.4 Manual adjustment in Level, Span modep.6915.3.5 Manual adjustment in Level, Max, Min modep.6915.4 Changing the temperature rangep.6915.4.1 Generalp.6915.4.2 Procedurep.6915.5 Changing the color palettep.7015.5.1 Generalp.7015.5.2 Procedurep.7115.6 Changing the object parametersp.7115.7 Calibrating the camerap.7215.7.1 Generalp.7215.7.2 Manual calibrationp.7215.8 Hiding all overlayp.7215.8.1 Generalp.7215.8.2 Procedurep.7316 Working with image modesp.7416.1 Generalp.7416.2 Image examplesp.7416.3 Selecting the image modep.7517 Working with measurement toolsp.7617.1 Generalp.7617.2 Adding/removing measurement toolsp.7617.3 Working with user presetsp.7617.3.1 Generalp.7617.3.2 Procedurep.7617.4 Resizing or moving a measurement toolp.7717.4.1 Generalp.7717.4.2 Procedurep.7717.5 Changing object parametersp.7817.5.1 Generalp.7817.5.2 Types of parametersp.7817.5.3 Recommended valuesp.7917.5.4 Procedurep.7917.5.5 Related topicsp.8017.6 Displaying values in the result table and displaying a graphp.8017.6.1 Generalp.8017.6.2 Procedurep.8117.7 Creating and setting up a difference calculationp.8117.7.1 Generalp.8117.7.2 Procedurep.8117.8 Setting a measurement alarmp.8217.8.1 Generalp.8217.8.2 Types of alarmp.8217.8.3 Alarm signalsp.8217.8.4 Procedurep.8318 Working with color alarms and isothermsp.8518.1 Color alarmsp.8518.1.1 Generalp.8518.1.2 Image examplesp.8518.2 Setting up above, below, and interval alarmsp.8618.3 Building isothermsp.8718.3.1 About the Condensation alarmp.8718.3.2 About the Insulation alarmp.8718.3.3 Setting up condensation and insulation alarmsp.8719 Annotating imagesp.8819.1 Generalp.8819.2 Adding a notep.8819.2.1 Generalp.8819.2.2 Procedurep.8819.3 Adding a tablep.8819.3.1 Generalp.8819.3.2 Procedurep.8919.4 Adding a voice annotationp.8919.4.1 Generalp.8919.4.2 Procedurep.9019.5 Adding a sketchp.9019.5.1 Generalp.9019.5.2 Procedurep.9020 Programming the camera (time lapse)p.9220.1 Generalp.9220.2 Procedurep.9221 Recording video clipsp.9321.1 Generalp.9321.2 Procedurep.9322 Screening alarmp.9422.1 Generalp.9422.2 Procedurep.9423 Pairing Bluetooth devicesp.9523.1 Generalp.9523.2 Procedurep.9524 Configuring Wi-Fip.9624.1 Generalp.9624.2 Setting up a wireless access point (most common use)p.9624.3 Connecting the camera to a WLAN (less common use)p.9625 Changing settingsp.9725.1 Generalp.9725.1.1 Define user presetsp.9725.1.2 Camera temperature rangep.9725.1.3 Save options & storagep.9725.1.4 Programmable buttonsp.9825.1.5 Device settingsp.9925.2 Procedurep.10126 Technical datap.10226.1 Online field-of-view calculatorp.10226.2 Note about technical datap.10226.3 Note about authoritative versionsp.10226.4 FLIR T1020 12°p.10326.5 FLIR T1020 28°p.11026.6 FLIR T1020 45°p.11726.7 FLIR T1020 28° and 12°p.12426.8 FLIR T1020 28° and 45°p.13126.9 FLIR T1020 28°, 12°, and 45°p.13826.10 FLIR T1030sc 12°p.14526.11 FLIR T1030sc 28°p.15226.12 FLIR T1030sc 45°p.15926.13 FLIR T1040 12°p.16626.14 FLIR T1040 28°p.17326.15 FLIR T1040 45°p.18026.16 FLIR T1050sc 12°p.18726.17 FLIR T1050sc 28°p.19426.18 FLIR T1050sc 45°p.20126.19 IR lens, f=36 mm (28°) with casep.20826.20 Close-up lens 3× (51 µm) with casep.21026.21 IR lens f=21.2 mm (45°) with casep.21126.22 IR lens f=83.4 mm (12°) with casep.21326.23 FLIR T10xx SC kitp.21527 Mechanical drawingsp.21728 Digital I/O pin configurationp.22528.1 Pin configuration for the Digital I/O connector on the HSI boxp.22529 Digital I/O connection diagramp.22630 CE Declaration of conformityp.22831 Cleaning the camerap.23031.1 Camera housing, cables, and other itemsp.23031.1.1 Liquidsp.23031.1.2 Equipmentp.23031.1.3 Procedurep.23031.2 Infrared lensp.23031.2.1 Liquidsp.23031.2.2 Equipmentp.23031.2.3 Procedurep.23031.3 Infrared detectorp.23131.3.1 Generalp.23131.3.2 Procedurep.23132 Application examplesp.23232.1 Moisture & water damagep.23232.1.1 Generalp.23232.1.2 Figurep.23232.2 Faulty contact in socketp.23232.2.1 Generalp.23232.2.2 Figurep.23332.3 Oxidized socketp.23332.3.1 Generalp.23332.3.2 Figurep.23332.4 Insulation deficienciesp.23432.4.1 Generalp.23432.4.2 Figurep.23432.5 Draftp.23532.5.1 Generalp.23532.5.2 Figurep.23533 About FLIR Systemsp.23733.1 More than just an infrared camerap.23833.2 Sharing our knowledgep.23833.3 Supporting our customersp.23934 Glossaryp.24035 Thermographic measurement techniquesp.24335.1 Introductionp.24335.2 Emissivityp.24335.2.1 Finding the emissivity of a samplep.24335.3 Reflected apparent temperaturep.24735.4 Distancep.24735.5 Relative humidityp.24735.6 Other parametersp.24736 History of infrared technologyp.24837 Theory of thermographyp.25137.1 Introductionp.25137.2 The electromagnetic spectrump.25137.3 Blackbody radiationp.25137.3.1 Planck’s lawp.25237.3.2 Wien’s displacement lawp.25337.3.3 Stefan-Boltzmann's lawp.25437.3.4 Non-blackbody emittersp.25537.4 Infrared semi-transparent materialsp.25738 The measurement formulap.25839 Emissivity tablesp.26239.1 Referencesp.26239.2 Tablesp.262
Page 9 of the Flir T1020 user manual — Table of contents
Page 9 · click to enlarge
Page 9

Table of contents

1 Disclaimersp.151.1 Legal disclaimerp.151.2 Usage statisticsp.151.3 Changes to registryp.151.4 U.S. Government Regulationsp.161.5 Copyrightp.161.6 Quality assurancep.161.7 Patentsp.161.8 Third-party licensesp.171.8.1 GNU Lesser General Public License (LGPL)p.171.8.2 Fonts (Source Han Sans)p.171.8.3 Fonts (DejaVu)p.172 Safety informationp.183 Notice to userp.233.1 User-to-user forumsp.233.2 Calibrationp.233.3 Accuracyp.233.4 Disposal of electronic wastep.233.5 Trainingp.233.6 Documentation updatesp.233.7 Important note about this manualp.233.8 Note about authoritative versionsp.244 Customer helpp.254.1 Generalp.254.2 Submitting a questionp.254.3 Downloadsp.265 Introductionp.275.1 General descriptionp.275.2 Key benefitsp.276 Quick start guidep.286.1 Procedurep.287 About FLIR Tools/Tools+p.297.1 Introductionp.297.2 Workflowp.307.2.1 Generalp.307.2.2 Figurep.307.2.3 Explanationp.308 Using the high-speed interface (HSI)p.318.1 Generalp.318.2 System overviewp.318.2.1 Figurep.318.2.2 Explanationp.318.3 Quick start guidep.328.4 HSI box indicator LEDp.328.5 Digital I/Op.329 A note about ergonomicsp.339.1 Generalp.339.2 Figurep.3310 Camera partsp.3410.1 View from the rightp.3410.1.1 Figurep.3410.1.2 Explanationp.3410.2 View from the leftp.3510.2.1 Figurep.3510.2.2 Explanationp.3510.3 View from the bottomp.3610.3.1 Figurep.3610.3.2 Explanationp.3610.4 View from the rearp.3710.4.1 Figurep.3710.4.2 Explanationp.3710.5 Neck strap attachment pointsp.3910.5.1 Figurep.3910.6 Battery condition LED indicatorp.3910.6.1 Figurep.3910.6.2 Explanationp.3910.7 Power LED indicatorp.4010.7.1 Figurep.4010.7.2 Explanationp.4010.8 Laser pointerp.4010.8.1 Figurep.4010.8.2 Laser warning labelp.4110.8.3 Laser rules and regulationsp.4111 Screen elementsp.4211.1 Figurep.4211.2 Explanationp.4211.3 Status icons and indicatorsp.4211.4 Image overlay informationp.4312 Navigating the menu systemp.4412.1 Generalp.4412.2 Navigating using the joystickp.4413 Handling the camerap.4513.1 Charging the batteryp.4513.1.1 Using the power supply to charge the batteryp.4513.1.2 Using the stand-alone battery charger to charge the batteryp.4513.2 Turning on the camerap.4513.2.1 Procedurep.4513.3 Turning off the camerap.4513.3.1 Procedurep.4513.4 Adjusting the viewfinder’s dioptric correction (sharpness)p.4613.4.1 Figurep.4613.4.2 Procedurep.4613.5 Adjusting the angle of the lensp.4713.5.1 Figurep.4713.6 Adjusting the infrared camera focus manuallyp.4713.6.1 Figurep.4713.6.2 Procedurep.4713.7 Autofocusing the infrared camerap.4813.7.1 Generalp.4813.7.2 Figurep.4813.7.3 Procedurep.4813.8 Continuous autofocusp.4913.8.1 Generalp.4913.8.2 Procedurep.4913.9 Operating the laser pointerp.4913.9.1 Figurep.5013.9.2 Procedurep.5013.10 Using the digital zoom functionp.5013.10.1 Generalp.5013.10.2 Figurep.5113.10.3 Procedurep.5113.11 Assigning functions to the programmable buttonsp.5113.11.1 Generalp.5113.11.2 Procedurep.5213.12 Using the camera lamp as a flashp.5213.12.1 Generalp.5213.12.2 Procedurep.5213.13 Changing lensesp.5213.14 Using the close-up lensp.5613.14.1 Generalp.5613.14.2 Attaching the close-up lensp.5613.14.3 Removing the close-up lensp.5813.15 Calibrating the compassp.6013.15.1 Procedurep.6014 Saving and working with imagesp.6114.1 About image filesp.6114.1.1 Generalp.6114.1.2 File-naming conventionp.6114.1.3 Image capacityp.6114.1.4 About UltraMaxp.6114.2 Saving an imagep.6114.2.1 Generalp.6114.2.2 Procedurep.6214.3 Previewing an imagep.6214.3.1 Generalp.6214.3.2 Procedurep.6214.4 Opening a saved imagep.6214.4.1 Generalp.6214.4.2 Procedurep.6214.5 Editing a saved imagep.6314.5.1 Generalp.6314.5.2 Procedurep.6314.5.3 Related topicsp.6314.6 Creating a PDF report in the camerap.6314.6.1 Generalp.6314.6.2 Naming conventionp.6414.6.3 Procedurep.6414.7 Deleting an imagep.6414.7.1 Generalp.6414.7.2 Procedurep.6414.8 Deleting multiple imagesp.6414.8.1 Generalp.6414.8.2 Procedurep.6414.9 Deleting all imagesp.6514.9.1 Generalp.6514.9.2 Procedurep.6514.10 Resetting the image counterp.6514.10.1 Generalp.6514.10.2 Procedurep.6515 Achieving a good imagep.6715.1 Generalp.6715.2 Adjusting the infrared camera focusp.6715.3 Adjusting the infrared imagep.6715.3.1 Generalp.6715.3.2 Example 1p.6815.3.3 Example 2p.6815.3.4 Manual adjustment in Level, Span modep.6915.3.5 Manual adjustment in Level, Max, Min modep.6915.4 Changing the temperature rangep.6915.4.1 Generalp.6915.4.2 Procedurep.6915.5 Changing the color palettep.7015.5.1 Generalp.7015.5.2 Procedurep.7115.6 Changing the object parametersp.7115.7 Calibrating the camerap.7215.7.1 Generalp.7215.7.2 Manual calibrationp.7215.8 Hiding all overlayp.7215.8.1 Generalp.7215.8.2 Procedurep.7316 Working with image modesp.7416.1 Generalp.7416.2 Image examplesp.7416.3 Selecting the image modep.7517 Working with measurement toolsp.7617.1 Generalp.7617.2 Adding/removing measurement toolsp.7617.3 Working with user presetsp.7617.3.1 Generalp.7617.3.2 Procedurep.7617.4 Resizing or moving a measurement toolp.7717.4.1 Generalp.7717.4.2 Procedurep.7717.5 Changing object parametersp.7817.5.1 Generalp.7817.5.2 Types of parametersp.7817.5.3 Recommended valuesp.7917.5.4 Procedurep.7917.5.5 Related topicsp.8017.6 Displaying values in the result table and displaying a graphp.8017.6.1 Generalp.8017.6.2 Procedurep.8117.7 Creating and setting up a difference calculationp.8117.7.1 Generalp.8117.7.2 Procedurep.8117.8 Setting a measurement alarmp.8217.8.1 Generalp.8217.8.2 Types of alarmp.8217.8.3 Alarm signalsp.8217.8.4 Procedurep.8318 Working with color alarms and isothermsp.8518.1 Color alarmsp.8518.1.1 Generalp.8518.1.2 Image examplesp.8518.2 Setting up above, below, and interval alarmsp.8618.3 Building isothermsp.8718.3.1 About the Condensation alarmp.8718.3.2 About the Insulation alarmp.8718.3.3 Setting up condensation and insulation alarmsp.8719 Annotating imagesp.8819.1 Generalp.8819.2 Adding a notep.8819.2.1 Generalp.8819.2.2 Procedurep.8819.3 Adding a tablep.8819.3.1 Generalp.8819.3.2 Procedurep.8919.4 Adding a voice annotationp.8919.4.1 Generalp.8919.4.2 Procedurep.9019.5 Adding a sketchp.9019.5.1 Generalp.9019.5.2 Procedurep.9020 Programming the camera (time lapse)p.9220.1 Generalp.9220.2 Procedurep.9221 Recording video clipsp.9321.1 Generalp.9321.2 Procedurep.9322 Screening alarmp.9422.1 Generalp.9422.2 Procedurep.9423 Pairing Bluetooth devicesp.9523.1 Generalp.9523.2 Procedurep.9524 Configuring Wi-Fip.9624.1 Generalp.9624.2 Setting up a wireless access point (most common use)p.9624.3 Connecting the camera to a WLAN (less common use)p.9625 Changing settingsp.9725.1 Generalp.9725.1.1 Define user presetsp.9725.1.2 Camera temperature rangep.9725.1.3 Save options & storagep.9725.1.4 Programmable buttonsp.9825.1.5 Device settingsp.9925.2 Procedurep.10126 Technical datap.10226.1 Online field-of-view calculatorp.10226.2 Note about technical datap.10226.3 Note about authoritative versionsp.10226.4 FLIR T1020 12°p.10326.5 FLIR T1020 28°p.11026.6 FLIR T1020 45°p.11726.7 FLIR T1020 28° and 12°p.12426.8 FLIR T1020 28° and 45°p.13126.9 FLIR T1020 28°, 12°, and 45°p.13826.10 FLIR T1030sc 12°p.14526.11 FLIR T1030sc 28°p.15226.12 FLIR T1030sc 45°p.15926.13 FLIR T1040 12°p.16626.14 FLIR T1040 28°p.17326.15 FLIR T1040 45°p.18026.16 FLIR T1050sc 12°p.18726.17 FLIR T1050sc 28°p.19426.18 FLIR T1050sc 45°p.20126.19 IR lens, f=36 mm (28°) with casep.20826.20 Close-up lens 3× (51 µm) with casep.21026.21 IR lens f=21.2 mm (45°) with casep.21126.22 IR lens f=83.4 mm (12°) with casep.21326.23 FLIR T10xx SC kitp.21527 Mechanical drawingsp.21728 Digital I/O pin configurationp.22528.1 Pin configuration for the Digital I/O connector on the HSI boxp.22529 Digital I/O connection diagramp.22630 CE Declaration of conformityp.22831 Cleaning the camerap.23031.1 Camera housing, cables, and other itemsp.23031.1.1 Liquidsp.23031.1.2 Equipmentp.23031.1.3 Procedurep.23031.2 Infrared lensp.23031.2.1 Liquidsp.23031.2.2 Equipmentp.23031.2.3 Procedurep.23031.3 Infrared detectorp.23131.3.1 Generalp.23131.3.2 Procedurep.23132 Application examplesp.23232.1 Moisture & water damagep.23232.1.1 Generalp.23232.1.2 Figurep.23232.2 Faulty contact in socketp.23232.2.1 Generalp.23232.2.2 Figurep.23332.3 Oxidized socketp.23332.3.1 Generalp.23332.3.2 Figurep.23332.4 Insulation deficienciesp.23432.4.1 Generalp.23432.4.2 Figurep.23432.5 Draftp.23532.5.1 Generalp.23532.5.2 Figurep.23533 About FLIR Systemsp.23733.1 More than just an infrared camerap.23833.2 Sharing our knowledgep.23833.3 Supporting our customersp.23934 Glossaryp.24035 Thermographic measurement techniquesp.24335.1 Introductionp.24335.2 Emissivityp.24335.2.1 Finding the emissivity of a samplep.24335.3 Reflected apparent temperaturep.24735.4 Distancep.24735.5 Relative humidityp.24735.6 Other parametersp.24736 History of infrared technologyp.24837 Theory of thermographyp.25137.1 Introductionp.25137.2 The electromagnetic spectrump.25137.3 Blackbody radiationp.25137.3.1 Planck’s lawp.25237.3.2 Wien’s displacement lawp.25337.3.3 Stefan-Boltzmann's lawp.25437.3.4 Non-blackbody emittersp.25537.4 Infrared semi-transparent materialsp.25738 The measurement formulap.25839 Emissivity tablesp.26239.1 Referencesp.26239.2 Tablesp.262
Page 10 of the Flir T1020 user manual — Table of contents
Page 10 · click to enlarge
Page 10

Table of contents

1 Disclaimersp.151.1 Legal disclaimerp.151.2 Usage statisticsp.151.3 Changes to registryp.151.4 U.S. Government Regulationsp.161.5 Copyrightp.161.6 Quality assurancep.161.7 Patentsp.161.8 Third-party licensesp.171.8.1 GNU Lesser General Public License (LGPL)p.171.8.2 Fonts (Source Han Sans)p.171.8.3 Fonts (DejaVu)p.172 Safety informationp.183 Notice to userp.233.1 User-to-user forumsp.233.2 Calibrationp.233.3 Accuracyp.233.4 Disposal of electronic wastep.233.5 Trainingp.233.6 Documentation updatesp.233.7 Important note about this manualp.233.8 Note about authoritative versionsp.244 Customer helpp.254.1 Generalp.254.2 Submitting a questionp.254.3 Downloadsp.265 Introductionp.275.1 General descriptionp.275.2 Key benefitsp.276 Quick start guidep.286.1 Procedurep.287 About FLIR Tools/Tools+p.297.1 Introductionp.297.2 Workflowp.307.2.1 Generalp.307.2.2 Figurep.307.2.3 Explanationp.308 Using the high-speed interface (HSI)p.318.1 Generalp.318.2 System overviewp.318.2.1 Figurep.318.2.2 Explanationp.318.3 Quick start guidep.328.4 HSI box indicator LEDp.328.5 Digital I/Op.329 A note about ergonomicsp.339.1 Generalp.339.2 Figurep.3310 Camera partsp.3410.1 View from the rightp.3410.1.1 Figurep.3410.1.2 Explanationp.3410.2 View from the leftp.3510.2.1 Figurep.3510.2.2 Explanationp.3510.3 View from the bottomp.3610.3.1 Figurep.3610.3.2 Explanationp.3610.4 View from the rearp.3710.4.1 Figurep.3710.4.2 Explanationp.3710.5 Neck strap attachment pointsp.3910.5.1 Figurep.3910.6 Battery condition LED indicatorp.3910.6.1 Figurep.3910.6.2 Explanationp.3910.7 Power LED indicatorp.4010.7.1 Figurep.4010.7.2 Explanationp.4010.8 Laser pointerp.4010.8.1 Figurep.4010.8.2 Laser warning labelp.4110.8.3 Laser rules and regulationsp.4111 Screen elementsp.4211.1 Figurep.4211.2 Explanationp.4211.3 Status icons and indicatorsp.4211.4 Image overlay informationp.4312 Navigating the menu systemp.4412.1 Generalp.4412.2 Navigating using the joystickp.4413 Handling the camerap.4513.1 Charging the batteryp.4513.1.1 Using the power supply to charge the batteryp.4513.1.2 Using the stand-alone battery charger to charge the batteryp.4513.2 Turning on the camerap.4513.2.1 Procedurep.4513.3 Turning off the camerap.4513.3.1 Procedurep.4513.4 Adjusting the viewfinder’s dioptric correction (sharpness)p.4613.4.1 Figurep.4613.4.2 Procedurep.4613.5 Adjusting the angle of the lensp.4713.5.1 Figurep.4713.6 Adjusting the infrared camera focus manuallyp.4713.6.1 Figurep.4713.6.2 Procedurep.4713.7 Autofocusing the infrared camerap.4813.7.1 Generalp.4813.7.2 Figurep.4813.7.3 Procedurep.4813.8 Continuous autofocusp.4913.8.1 Generalp.4913.8.2 Procedurep.4913.9 Operating the laser pointerp.4913.9.1 Figurep.5013.9.2 Procedurep.5013.10 Using the digital zoom functionp.5013.10.1 Generalp.5013.10.2 Figurep.5113.10.3 Procedurep.5113.11 Assigning functions to the programmable buttonsp.5113.11.1 Generalp.5113.11.2 Procedurep.5213.12 Using the camera lamp as a flashp.5213.12.1 Generalp.5213.12.2 Procedurep.5213.13 Changing lensesp.5213.14 Using the close-up lensp.5613.14.1 Generalp.5613.14.2 Attaching the close-up lensp.5613.14.3 Removing the close-up lensp.5813.15 Calibrating the compassp.6013.15.1 Procedurep.6014 Saving and working with imagesp.6114.1 About image filesp.6114.1.1 Generalp.6114.1.2 File-naming conventionp.6114.1.3 Image capacityp.6114.1.4 About UltraMaxp.6114.2 Saving an imagep.6114.2.1 Generalp.6114.2.2 Procedurep.6214.3 Previewing an imagep.6214.3.1 Generalp.6214.3.2 Procedurep.6214.4 Opening a saved imagep.6214.4.1 Generalp.6214.4.2 Procedurep.6214.5 Editing a saved imagep.6314.5.1 Generalp.6314.5.2 Procedurep.6314.5.3 Related topicsp.6314.6 Creating a PDF report in the camerap.6314.6.1 Generalp.6314.6.2 Naming conventionp.6414.6.3 Procedurep.6414.7 Deleting an imagep.6414.7.1 Generalp.6414.7.2 Procedurep.6414.8 Deleting multiple imagesp.6414.8.1 Generalp.6414.8.2 Procedurep.6414.9 Deleting all imagesp.6514.9.1 Generalp.6514.9.2 Procedurep.6514.10 Resetting the image counterp.6514.10.1 Generalp.6514.10.2 Procedurep.6515 Achieving a good imagep.6715.1 Generalp.6715.2 Adjusting the infrared camera focusp.6715.3 Adjusting the infrared imagep.6715.3.1 Generalp.6715.3.2 Example 1p.6815.3.3 Example 2p.6815.3.4 Manual adjustment in Level, Span modep.6915.3.5 Manual adjustment in Level, Max, Min modep.6915.4 Changing the temperature rangep.6915.4.1 Generalp.6915.4.2 Procedurep.6915.5 Changing the color palettep.7015.5.1 Generalp.7015.5.2 Procedurep.7115.6 Changing the object parametersp.7115.7 Calibrating the camerap.7215.7.1 Generalp.7215.7.2 Manual calibrationp.7215.8 Hiding all overlayp.7215.8.1 Generalp.7215.8.2 Procedurep.7316 Working with image modesp.7416.1 Generalp.7416.2 Image examplesp.7416.3 Selecting the image modep.7517 Working with measurement toolsp.7617.1 Generalp.7617.2 Adding/removing measurement toolsp.7617.3 Working with user presetsp.7617.3.1 Generalp.7617.3.2 Procedurep.7617.4 Resizing or moving a measurement toolp.7717.4.1 Generalp.7717.4.2 Procedurep.7717.5 Changing object parametersp.7817.5.1 Generalp.7817.5.2 Types of parametersp.7817.5.3 Recommended valuesp.7917.5.4 Procedurep.7917.5.5 Related topicsp.8017.6 Displaying values in the result table and displaying a graphp.8017.6.1 Generalp.8017.6.2 Procedurep.8117.7 Creating and setting up a difference calculationp.8117.7.1 Generalp.8117.7.2 Procedurep.8117.8 Setting a measurement alarmp.8217.8.1 Generalp.8217.8.2 Types of alarmp.8217.8.3 Alarm signalsp.8217.8.4 Procedurep.8318 Working with color alarms and isothermsp.8518.1 Color alarmsp.8518.1.1 Generalp.8518.1.2 Image examplesp.8518.2 Setting up above, below, and interval alarmsp.8618.3 Building isothermsp.8718.3.1 About the Condensation alarmp.8718.3.2 About the Insulation alarmp.8718.3.3 Setting up condensation and insulation alarmsp.8719 Annotating imagesp.8819.1 Generalp.8819.2 Adding a notep.8819.2.1 Generalp.8819.2.2 Procedurep.8819.3 Adding a tablep.8819.3.1 Generalp.8819.3.2 Procedurep.8919.4 Adding a voice annotationp.8919.4.1 Generalp.8919.4.2 Procedurep.9019.5 Adding a sketchp.9019.5.1 Generalp.9019.5.2 Procedurep.9020 Programming the camera (time lapse)p.9220.1 Generalp.9220.2 Procedurep.9221 Recording video clipsp.9321.1 Generalp.9321.2 Procedurep.9322 Screening alarmp.9422.1 Generalp.9422.2 Procedurep.9423 Pairing Bluetooth devicesp.9523.1 Generalp.9523.2 Procedurep.9524 Configuring Wi-Fip.9624.1 Generalp.9624.2 Setting up a wireless access point (most common use)p.9624.3 Connecting the camera to a WLAN (less common use)p.9625 Changing settingsp.9725.1 Generalp.9725.1.1 Define user presetsp.9725.1.2 Camera temperature rangep.9725.1.3 Save options & storagep.9725.1.4 Programmable buttonsp.9825.1.5 Device settingsp.9925.2 Procedurep.10126 Technical datap.10226.1 Online field-of-view calculatorp.10226.2 Note about technical datap.10226.3 Note about authoritative versionsp.10226.4 FLIR T1020 12°p.10326.5 FLIR T1020 28°p.11026.6 FLIR T1020 45°p.11726.7 FLIR T1020 28° and 12°p.12426.8 FLIR T1020 28° and 45°p.13126.9 FLIR T1020 28°, 12°, and 45°p.13826.10 FLIR T1030sc 12°p.14526.11 FLIR T1030sc 28°p.15226.12 FLIR T1030sc 45°p.15926.13 FLIR T1040 12°p.16626.14 FLIR T1040 28°p.17326.15 FLIR T1040 45°p.18026.16 FLIR T1050sc 12°p.18726.17 FLIR T1050sc 28°p.19426.18 FLIR T1050sc 45°p.20126.19 IR lens, f=36 mm (28°) with casep.20826.20 Close-up lens 3× (51 µm) with casep.21026.21 IR lens f=21.2 mm (45°) with casep.21126.22 IR lens f=83.4 mm (12°) with casep.21326.23 FLIR T10xx SC kitp.21527 Mechanical drawingsp.21728 Digital I/O pin configurationp.22528.1 Pin configuration for the Digital I/O connector on the HSI boxp.22529 Digital I/O connection diagramp.22630 CE Declaration of conformityp.22831 Cleaning the camerap.23031.1 Camera housing, cables, and other itemsp.23031.1.1 Liquidsp.23031.1.2 Equipmentp.23031.1.3 Procedurep.23031.2 Infrared lensp.23031.2.1 Liquidsp.23031.2.2 Equipmentp.23031.2.3 Procedurep.23031.3 Infrared detectorp.23131.3.1 Generalp.23131.3.2 Procedurep.23132 Application examplesp.23232.1 Moisture & water damagep.23232.1.1 Generalp.23232.1.2 Figurep.23232.2 Faulty contact in socketp.23232.2.1 Generalp.23232.2.2 Figurep.23332.3 Oxidized socketp.23332.3.1 Generalp.23332.3.2 Figurep.23332.4 Insulation deficienciesp.23432.4.1 Generalp.23432.4.2 Figurep.23432.5 Draftp.23532.5.1 Generalp.23532.5.2 Figurep.23533 About FLIR Systemsp.23733.1 More than just an infrared camerap.23833.2 Sharing our knowledgep.23833.3 Supporting our customersp.23934 Glossaryp.24035 Thermographic measurement techniquesp.24335.1 Introductionp.24335.2 Emissivityp.24335.2.1 Finding the emissivity of a samplep.24335.3 Reflected apparent temperaturep.24735.4 Distancep.24735.5 Relative humidityp.24735.6 Other parametersp.24736 History of infrared technologyp.24837 Theory of thermographyp.25137.1 Introductionp.25137.2 The electromagnetic spectrump.25137.3 Blackbody radiationp.25137.3.1 Planck’s lawp.25237.3.2 Wien’s displacement lawp.25337.3.3 Stefan-Boltzmann's lawp.25437.3.4 Non-blackbody emittersp.25537.4 Infrared semi-transparent materialsp.25738 The measurement formulap.25839 Emissivity tablesp.26239.1 Referencesp.26239.2 Tablesp.262
Page 11 of the Flir T1020 user manual — Table of contents
Page 11 · click to enlarge
Page 11

Table of contents

1 Disclaimersp.151.1 Legal disclaimerp.151.2 Usage statisticsp.151.3 Changes to registryp.151.4 U.S. Government Regulationsp.161.5 Copyrightp.161.6 Quality assurancep.161.7 Patentsp.161.8 Third-party licensesp.171.8.1 GNU Lesser General Public License (LGPL)p.171.8.2 Fonts (Source Han Sans)p.171.8.3 Fonts (DejaVu)p.172 Safety informationp.183 Notice to userp.233.1 User-to-user forumsp.233.2 Calibrationp.233.3 Accuracyp.233.4 Disposal of electronic wastep.233.5 Trainingp.233.6 Documentation updatesp.233.7 Important note about this manualp.233.8 Note about authoritative versionsp.244 Customer helpp.254.1 Generalp.254.2 Submitting a questionp.254.3 Downloadsp.265 Introductionp.275.1 General descriptionp.275.2 Key benefitsp.276 Quick start guidep.286.1 Procedurep.287 About FLIR Tools/Tools+p.297.1 Introductionp.297.2 Workflowp.307.2.1 Generalp.307.2.2 Figurep.307.2.3 Explanationp.308 Using the high-speed interface (HSI)p.318.1 Generalp.318.2 System overviewp.318.2.1 Figurep.318.2.2 Explanationp.318.3 Quick start guidep.328.4 HSI box indicator LEDp.328.5 Digital I/Op.329 A note about ergonomicsp.339.1 Generalp.339.2 Figurep.3310 Camera partsp.3410.1 View from the rightp.3410.1.1 Figurep.3410.1.2 Explanationp.3410.2 View from the leftp.3510.2.1 Figurep.3510.2.2 Explanationp.3510.3 View from the bottomp.3610.3.1 Figurep.3610.3.2 Explanationp.3610.4 View from the rearp.3710.4.1 Figurep.3710.4.2 Explanationp.3710.5 Neck strap attachment pointsp.3910.5.1 Figurep.3910.6 Battery condition LED indicatorp.3910.6.1 Figurep.3910.6.2 Explanationp.3910.7 Power LED indicatorp.4010.7.1 Figurep.4010.7.2 Explanationp.4010.8 Laser pointerp.4010.8.1 Figurep.4010.8.2 Laser warning labelp.4110.8.3 Laser rules and regulationsp.4111 Screen elementsp.4211.1 Figurep.4211.2 Explanationp.4211.3 Status icons and indicatorsp.4211.4 Image overlay informationp.4312 Navigating the menu systemp.4412.1 Generalp.4412.2 Navigating using the joystickp.4413 Handling the camerap.4513.1 Charging the batteryp.4513.1.1 Using the power supply to charge the batteryp.4513.1.2 Using the stand-alone battery charger to charge the batteryp.4513.2 Turning on the camerap.4513.2.1 Procedurep.4513.3 Turning off the camerap.4513.3.1 Procedurep.4513.4 Adjusting the viewfinder’s dioptric correction (sharpness)p.4613.4.1 Figurep.4613.4.2 Procedurep.4613.5 Adjusting the angle of the lensp.4713.5.1 Figurep.4713.6 Adjusting the infrared camera focus manuallyp.4713.6.1 Figurep.4713.6.2 Procedurep.4713.7 Autofocusing the infrared camerap.4813.7.1 Generalp.4813.7.2 Figurep.4813.7.3 Procedurep.4813.8 Continuous autofocusp.4913.8.1 Generalp.4913.8.2 Procedurep.4913.9 Operating the laser pointerp.4913.9.1 Figurep.5013.9.2 Procedurep.5013.10 Using the digital zoom functionp.5013.10.1 Generalp.5013.10.2 Figurep.5113.10.3 Procedurep.5113.11 Assigning functions to the programmable buttonsp.5113.11.1 Generalp.5113.11.2 Procedurep.5213.12 Using the camera lamp as a flashp.5213.12.1 Generalp.5213.12.2 Procedurep.5213.13 Changing lensesp.5213.14 Using the close-up lensp.5613.14.1 Generalp.5613.14.2 Attaching the close-up lensp.5613.14.3 Removing the close-up lensp.5813.15 Calibrating the compassp.6013.15.1 Procedurep.6014 Saving and working with imagesp.6114.1 About image filesp.6114.1.1 Generalp.6114.1.2 File-naming conventionp.6114.1.3 Image capacityp.6114.1.4 About UltraMaxp.6114.2 Saving an imagep.6114.2.1 Generalp.6114.2.2 Procedurep.6214.3 Previewing an imagep.6214.3.1 Generalp.6214.3.2 Procedurep.6214.4 Opening a saved imagep.6214.4.1 Generalp.6214.4.2 Procedurep.6214.5 Editing a saved imagep.6314.5.1 Generalp.6314.5.2 Procedurep.6314.5.3 Related topicsp.6314.6 Creating a PDF report in the camerap.6314.6.1 Generalp.6314.6.2 Naming conventionp.6414.6.3 Procedurep.6414.7 Deleting an imagep.6414.7.1 Generalp.6414.7.2 Procedurep.6414.8 Deleting multiple imagesp.6414.8.1 Generalp.6414.8.2 Procedurep.6414.9 Deleting all imagesp.6514.9.1 Generalp.6514.9.2 Procedurep.6514.10 Resetting the image counterp.6514.10.1 Generalp.6514.10.2 Procedurep.6515 Achieving a good imagep.6715.1 Generalp.6715.2 Adjusting the infrared camera focusp.6715.3 Adjusting the infrared imagep.6715.3.1 Generalp.6715.3.2 Example 1p.6815.3.3 Example 2p.6815.3.4 Manual adjustment in Level, Span modep.6915.3.5 Manual adjustment in Level, Max, Min modep.6915.4 Changing the temperature rangep.6915.4.1 Generalp.6915.4.2 Procedurep.6915.5 Changing the color palettep.7015.5.1 Generalp.7015.5.2 Procedurep.7115.6 Changing the object parametersp.7115.7 Calibrating the camerap.7215.7.1 Generalp.7215.7.2 Manual calibrationp.7215.8 Hiding all overlayp.7215.8.1 Generalp.7215.8.2 Procedurep.7316 Working with image modesp.7416.1 Generalp.7416.2 Image examplesp.7416.3 Selecting the image modep.7517 Working with measurement toolsp.7617.1 Generalp.7617.2 Adding/removing measurement toolsp.7617.3 Working with user presetsp.7617.3.1 Generalp.7617.3.2 Procedurep.7617.4 Resizing or moving a measurement toolp.7717.4.1 Generalp.7717.4.2 Procedurep.7717.5 Changing object parametersp.7817.5.1 Generalp.7817.5.2 Types of parametersp.7817.5.3 Recommended valuesp.7917.5.4 Procedurep.7917.5.5 Related topicsp.8017.6 Displaying values in the result table and displaying a graphp.8017.6.1 Generalp.8017.6.2 Procedurep.8117.7 Creating and setting up a difference calculationp.8117.7.1 Generalp.8117.7.2 Procedurep.8117.8 Setting a measurement alarmp.8217.8.1 Generalp.8217.8.2 Types of alarmp.8217.8.3 Alarm signalsp.8217.8.4 Procedurep.8318 Working with color alarms and isothermsp.8518.1 Color alarmsp.8518.1.1 Generalp.8518.1.2 Image examplesp.8518.2 Setting up above, below, and interval alarmsp.8618.3 Building isothermsp.8718.3.1 About the Condensation alarmp.8718.3.2 About the Insulation alarmp.8718.3.3 Setting up condensation and insulation alarmsp.8719 Annotating imagesp.8819.1 Generalp.8819.2 Adding a notep.8819.2.1 Generalp.8819.2.2 Procedurep.8819.3 Adding a tablep.8819.3.1 Generalp.8819.3.2 Procedurep.8919.4 Adding a voice annotationp.8919.4.1 Generalp.8919.4.2 Procedurep.9019.5 Adding a sketchp.9019.5.1 Generalp.9019.5.2 Procedurep.9020 Programming the camera (time lapse)p.9220.1 Generalp.9220.2 Procedurep.9221 Recording video clipsp.9321.1 Generalp.9321.2 Procedurep.9322 Screening alarmp.9422.1 Generalp.9422.2 Procedurep.9423 Pairing Bluetooth devicesp.9523.1 Generalp.9523.2 Procedurep.9524 Configuring Wi-Fip.9624.1 Generalp.9624.2 Setting up a wireless access point (most common use)p.9624.3 Connecting the camera to a WLAN (less common use)p.9625 Changing settingsp.9725.1 Generalp.9725.1.1 Define user presetsp.9725.1.2 Camera temperature rangep.9725.1.3 Save options & storagep.9725.1.4 Programmable buttonsp.9825.1.5 Device settingsp.9925.2 Procedurep.10126 Technical datap.10226.1 Online field-of-view calculatorp.10226.2 Note about technical datap.10226.3 Note about authoritative versionsp.10226.4 FLIR T1020 12°p.10326.5 FLIR T1020 28°p.11026.6 FLIR T1020 45°p.11726.7 FLIR T1020 28° and 12°p.12426.8 FLIR T1020 28° and 45°p.13126.9 FLIR T1020 28°, 12°, and 45°p.13826.10 FLIR T1030sc 12°p.14526.11 FLIR T1030sc 28°p.15226.12 FLIR T1030sc 45°p.15926.13 FLIR T1040 12°p.16626.14 FLIR T1040 28°p.17326.15 FLIR T1040 45°p.18026.16 FLIR T1050sc 12°p.18726.17 FLIR T1050sc 28°p.19426.18 FLIR T1050sc 45°p.20126.19 IR lens, f=36 mm (28°) with casep.20826.20 Close-up lens 3× (51 µm) with casep.21026.21 IR lens f=21.2 mm (45°) with casep.21126.22 IR lens f=83.4 mm (12°) with casep.21326.23 FLIR T10xx SC kitp.21527 Mechanical drawingsp.21728 Digital I/O pin configurationp.22528.1 Pin configuration for the Digital I/O connector on the HSI boxp.22529 Digital I/O connection diagramp.22630 CE Declaration of conformityp.22831 Cleaning the camerap.23031.1 Camera housing, cables, and other itemsp.23031.1.1 Liquidsp.23031.1.2 Equipmentp.23031.1.3 Procedurep.23031.2 Infrared lensp.23031.2.1 Liquidsp.23031.2.2 Equipmentp.23031.2.3 Procedurep.23031.3 Infrared detectorp.23131.3.1 Generalp.23131.3.2 Procedurep.23132 Application examplesp.23232.1 Moisture & water damagep.23232.1.1 Generalp.23232.1.2 Figurep.23232.2 Faulty contact in socketp.23232.2.1 Generalp.23232.2.2 Figurep.23332.3 Oxidized socketp.23332.3.1 Generalp.23332.3.2 Figurep.23332.4 Insulation deficienciesp.23432.4.1 Generalp.23432.4.2 Figurep.23432.5 Draftp.23532.5.1 Generalp.23532.5.2 Figurep.23533 About FLIR Systemsp.23733.1 More than just an infrared camerap.23833.2 Sharing our knowledgep.23833.3 Supporting our customersp.23934 Glossaryp.24035 Thermographic measurement techniquesp.24335.1 Introductionp.24335.2 Emissivityp.24335.2.1 Finding the emissivity of a samplep.24335.3 Reflected apparent temperaturep.24735.4 Distancep.24735.5 Relative humidityp.24735.6 Other parametersp.24736 History of infrared technologyp.24837 Theory of thermographyp.25137.1 Introductionp.25137.2 The electromagnetic spectrump.25137.3 Blackbody radiationp.25137.3.1 Planck’s lawp.25237.3.2 Wien’s displacement lawp.25337.3.3 Stefan-Boltzmann's lawp.25437.3.4 Non-blackbody emittersp.25537.4 Infrared semi-transparent materialsp.25738 The measurement formulap.25839 Emissivity tablesp.26239.1 Referencesp.26239.2 Tablesp.262
Page 12 of the Flir T1020 user manual — Table of contents
Page 12 · click to enlarge
Page 12

Table of contents

1 Disclaimersp.151.1 Legal disclaimerp.151.2 Usage statisticsp.151.3 Changes to registryp.151.4 U.S. Government Regulationsp.161.5 Copyrightp.161.6 Quality assurancep.161.7 Patentsp.161.8 Third-party licensesp.171.8.1 GNU Lesser General Public License (LGPL)p.171.8.2 Fonts (Source Han Sans)p.171.8.3 Fonts (DejaVu)p.172 Safety informationp.183 Notice to userp.233.1 User-to-user forumsp.233.2 Calibrationp.233.3 Accuracyp.233.4 Disposal of electronic wastep.233.5 Trainingp.233.6 Documentation updatesp.233.7 Important note about this manualp.233.8 Note about authoritative versionsp.244 Customer helpp.254.1 Generalp.254.2 Submitting a questionp.254.3 Downloadsp.265 Introductionp.275.1 General descriptionp.275.2 Key benefitsp.276 Quick start guidep.286.1 Procedurep.287 About FLIR Tools/Tools+p.297.1 Introductionp.297.2 Workflowp.307.2.1 Generalp.307.2.2 Figurep.307.2.3 Explanationp.308 Using the high-speed interface (HSI)p.318.1 Generalp.318.2 System overviewp.318.2.1 Figurep.318.2.2 Explanationp.318.3 Quick start guidep.328.4 HSI box indicator LEDp.328.5 Digital I/Op.329 A note about ergonomicsp.339.1 Generalp.339.2 Figurep.3310 Camera partsp.3410.1 View from the rightp.3410.1.1 Figurep.3410.1.2 Explanationp.3410.2 View from the leftp.3510.2.1 Figurep.3510.2.2 Explanationp.3510.3 View from the bottomp.3610.3.1 Figurep.3610.3.2 Explanationp.3610.4 View from the rearp.3710.4.1 Figurep.3710.4.2 Explanationp.3710.5 Neck strap attachment pointsp.3910.5.1 Figurep.3910.6 Battery condition LED indicatorp.3910.6.1 Figurep.3910.6.2 Explanationp.3910.7 Power LED indicatorp.4010.7.1 Figurep.4010.7.2 Explanationp.4010.8 Laser pointerp.4010.8.1 Figurep.4010.8.2 Laser warning labelp.4110.8.3 Laser rules and regulationsp.4111 Screen elementsp.4211.1 Figurep.4211.2 Explanationp.4211.3 Status icons and indicatorsp.4211.4 Image overlay informationp.4312 Navigating the menu systemp.4412.1 Generalp.4412.2 Navigating using the joystickp.4413 Handling the camerap.4513.1 Charging the batteryp.4513.1.1 Using the power supply to charge the batteryp.4513.1.2 Using the stand-alone battery charger to charge the batteryp.4513.2 Turning on the camerap.4513.2.1 Procedurep.4513.3 Turning off the camerap.4513.3.1 Procedurep.4513.4 Adjusting the viewfinder’s dioptric correction (sharpness)p.4613.4.1 Figurep.4613.4.2 Procedurep.4613.5 Adjusting the angle of the lensp.4713.5.1 Figurep.4713.6 Adjusting the infrared camera focus manuallyp.4713.6.1 Figurep.4713.6.2 Procedurep.4713.7 Autofocusing the infrared camerap.4813.7.1 Generalp.4813.7.2 Figurep.4813.7.3 Procedurep.4813.8 Continuous autofocusp.4913.8.1 Generalp.4913.8.2 Procedurep.4913.9 Operating the laser pointerp.4913.9.1 Figurep.5013.9.2 Procedurep.5013.10 Using the digital zoom functionp.5013.10.1 Generalp.5013.10.2 Figurep.5113.10.3 Procedurep.5113.11 Assigning functions to the programmable buttonsp.5113.11.1 Generalp.5113.11.2 Procedurep.5213.12 Using the camera lamp as a flashp.5213.12.1 Generalp.5213.12.2 Procedurep.5213.13 Changing lensesp.5213.14 Using the close-up lensp.5613.14.1 Generalp.5613.14.2 Attaching the close-up lensp.5613.14.3 Removing the close-up lensp.5813.15 Calibrating the compassp.6013.15.1 Procedurep.6014 Saving and working with imagesp.6114.1 About image filesp.6114.1.1 Generalp.6114.1.2 File-naming conventionp.6114.1.3 Image capacityp.6114.1.4 About UltraMaxp.6114.2 Saving an imagep.6114.2.1 Generalp.6114.2.2 Procedurep.6214.3 Previewing an imagep.6214.3.1 Generalp.6214.3.2 Procedurep.6214.4 Opening a saved imagep.6214.4.1 Generalp.6214.4.2 Procedurep.6214.5 Editing a saved imagep.6314.5.1 Generalp.6314.5.2 Procedurep.6314.5.3 Related topicsp.6314.6 Creating a PDF report in the camerap.6314.6.1 Generalp.6314.6.2 Naming conventionp.6414.6.3 Procedurep.6414.7 Deleting an imagep.6414.7.1 Generalp.6414.7.2 Procedurep.6414.8 Deleting multiple imagesp.6414.8.1 Generalp.6414.8.2 Procedurep.6414.9 Deleting all imagesp.6514.9.1 Generalp.6514.9.2 Procedurep.6514.10 Resetting the image counterp.6514.10.1 Generalp.6514.10.2 Procedurep.6515 Achieving a good imagep.6715.1 Generalp.6715.2 Adjusting the infrared camera focusp.6715.3 Adjusting the infrared imagep.6715.3.1 Generalp.6715.3.2 Example 1p.6815.3.3 Example 2p.6815.3.4 Manual adjustment in Level, Span modep.6915.3.5 Manual adjustment in Level, Max, Min modep.6915.4 Changing the temperature rangep.6915.4.1 Generalp.6915.4.2 Procedurep.6915.5 Changing the color palettep.7015.5.1 Generalp.7015.5.2 Procedurep.7115.6 Changing the object parametersp.7115.7 Calibrating the camerap.7215.7.1 Generalp.7215.7.2 Manual calibrationp.7215.8 Hiding all overlayp.7215.8.1 Generalp.7215.8.2 Procedurep.7316 Working with image modesp.7416.1 Generalp.7416.2 Image examplesp.7416.3 Selecting the image modep.7517 Working with measurement toolsp.7617.1 Generalp.7617.2 Adding/removing measurement toolsp.7617.3 Working with user presetsp.7617.3.1 Generalp.7617.3.2 Procedurep.7617.4 Resizing or moving a measurement toolp.7717.4.1 Generalp.7717.4.2 Procedurep.7717.5 Changing object parametersp.7817.5.1 Generalp.7817.5.2 Types of parametersp.7817.5.3 Recommended valuesp.7917.5.4 Procedurep.7917.5.5 Related topicsp.8017.6 Displaying values in the result table and displaying a graphp.8017.6.1 Generalp.8017.6.2 Procedurep.8117.7 Creating and setting up a difference calculationp.8117.7.1 Generalp.8117.7.2 Procedurep.8117.8 Setting a measurement alarmp.8217.8.1 Generalp.8217.8.2 Types of alarmp.8217.8.3 Alarm signalsp.8217.8.4 Procedurep.8318 Working with color alarms and isothermsp.8518.1 Color alarmsp.8518.1.1 Generalp.8518.1.2 Image examplesp.8518.2 Setting up above, below, and interval alarmsp.8618.3 Building isothermsp.8718.3.1 About the Condensation alarmp.8718.3.2 About the Insulation alarmp.8718.3.3 Setting up condensation and insulation alarmsp.8719 Annotating imagesp.8819.1 Generalp.8819.2 Adding a notep.8819.2.1 Generalp.8819.2.2 Procedurep.8819.3 Adding a tablep.8819.3.1 Generalp.8819.3.2 Procedurep.8919.4 Adding a voice annotationp.8919.4.1 Generalp.8919.4.2 Procedurep.9019.5 Adding a sketchp.9019.5.1 Generalp.9019.5.2 Procedurep.9020 Programming the camera (time lapse)p.9220.1 Generalp.9220.2 Procedurep.9221 Recording video clipsp.9321.1 Generalp.9321.2 Procedurep.9322 Screening alarmp.9422.1 Generalp.9422.2 Procedurep.9423 Pairing Bluetooth devicesp.9523.1 Generalp.9523.2 Procedurep.9524 Configuring Wi-Fip.9624.1 Generalp.9624.2 Setting up a wireless access point (most common use)p.9624.3 Connecting the camera to a WLAN (less common use)p.9625 Changing settingsp.9725.1 Generalp.9725.1.1 Define user presetsp.9725.1.2 Camera temperature rangep.9725.1.3 Save options & storagep.9725.1.4 Programmable buttonsp.9825.1.5 Device settingsp.9925.2 Procedurep.10126 Technical datap.10226.1 Online field-of-view calculatorp.10226.2 Note about technical datap.10226.3 Note about authoritative versionsp.10226.4 FLIR T1020 12°p.10326.5 FLIR T1020 28°p.11026.6 FLIR T1020 45°p.11726.7 FLIR T1020 28° and 12°p.12426.8 FLIR T1020 28° and 45°p.13126.9 FLIR T1020 28°, 12°, and 45°p.13826.10 FLIR T1030sc 12°p.14526.11 FLIR T1030sc 28°p.15226.12 FLIR T1030sc 45°p.15926.13 FLIR T1040 12°p.16626.14 FLIR T1040 28°p.17326.15 FLIR T1040 45°p.18026.16 FLIR T1050sc 12°p.18726.17 FLIR T1050sc 28°p.19426.18 FLIR T1050sc 45°p.20126.19 IR lens, f=36 mm (28°) with casep.20826.20 Close-up lens 3× (51 µm) with casep.21026.21 IR lens f=21.2 mm (45°) with casep.21126.22 IR lens f=83.4 mm (12°) with casep.21326.23 FLIR T10xx SC kitp.21527 Mechanical drawingsp.21728 Digital I/O pin configurationp.22528.1 Pin configuration for the Digital I/O connector on the HSI boxp.22529 Digital I/O connection diagramp.22630 CE Declaration of conformityp.22831 Cleaning the camerap.23031.1 Camera housing, cables, and other itemsp.23031.1.1 Liquidsp.23031.1.2 Equipmentp.23031.1.3 Procedurep.23031.2 Infrared lensp.23031.2.1 Liquidsp.23031.2.2 Equipmentp.23031.2.3 Procedurep.23031.3 Infrared detectorp.23131.3.1 Generalp.23131.3.2 Procedurep.23132 Application examplesp.23232.1 Moisture & water damagep.23232.1.1 Generalp.23232.1.2 Figurep.23232.2 Faulty contact in socketp.23232.2.1 Generalp.23232.2.2 Figurep.23332.3 Oxidized socketp.23332.3.1 Generalp.23332.3.2 Figurep.23332.4 Insulation deficienciesp.23432.4.1 Generalp.23432.4.2 Figurep.23432.5 Draftp.23532.5.1 Generalp.23532.5.2 Figurep.23533 About FLIR Systemsp.23733.1 More than just an infrared camerap.23833.2 Sharing our knowledgep.23833.3 Supporting our customersp.23934 Glossaryp.24035 Thermographic measurement techniquesp.24335.1 Introductionp.24335.2 Emissivityp.24335.2.1 Finding the emissivity of a samplep.24335.3 Reflected apparent temperaturep.24735.4 Distancep.24735.5 Relative humidityp.24735.6 Other parametersp.24736 History of infrared technologyp.24837 Theory of thermographyp.25137.1 Introductionp.25137.2 The electromagnetic spectrump.25137.3 Blackbody radiationp.25137.3.1 Planck’s lawp.25237.3.2 Wien’s displacement lawp.25337.3.3 Stefan-Boltzmann's lawp.25437.3.4 Non-blackbody emittersp.25537.4 Infrared semi-transparent materialsp.25738 The measurement formulap.25839 Emissivity tablesp.26239.1 Referencesp.26239.2 Tablesp.262
Page 13 of the Flir T1020 user manual — Table of contents
Page 13 · click to enlarge
Page 13

Table of contents

1 Disclaimersp.151.1 Legal disclaimerp.151.2 Usage statisticsp.151.3 Changes to registryp.151.4 U.S. Government Regulationsp.161.5 Copyrightp.161.6 Quality assurancep.161.7 Patentsp.161.8 Third-party licensesp.171.8.1 GNU Lesser General Public License (LGPL)p.171.8.2 Fonts (Source Han Sans)p.171.8.3 Fonts (DejaVu)p.172 Safety informationp.183 Notice to userp.233.1 User-to-user forumsp.233.2 Calibrationp.233.3 Accuracyp.233.4 Disposal of electronic wastep.233.5 Trainingp.233.6 Documentation updatesp.233.7 Important note about this manualp.233.8 Note about authoritative versionsp.244 Customer helpp.254.1 Generalp.254.2 Submitting a questionp.254.3 Downloadsp.265 Introductionp.275.1 General descriptionp.275.2 Key benefitsp.276 Quick start guidep.286.1 Procedurep.287 About FLIR Tools/Tools+p.297.1 Introductionp.297.2 Workflowp.307.2.1 Generalp.307.2.2 Figurep.307.2.3 Explanationp.308 Using the high-speed interface (HSI)p.318.1 Generalp.318.2 System overviewp.318.2.1 Figurep.318.2.2 Explanationp.318.3 Quick start guidep.328.4 HSI box indicator LEDp.328.5 Digital I/Op.329 A note about ergonomicsp.339.1 Generalp.339.2 Figurep.3310 Camera partsp.3410.1 View from the rightp.3410.1.1 Figurep.3410.1.2 Explanationp.3410.2 View from the leftp.3510.2.1 Figurep.3510.2.2 Explanationp.3510.3 View from the bottomp.3610.3.1 Figurep.3610.3.2 Explanationp.3610.4 View from the rearp.3710.4.1 Figurep.3710.4.2 Explanationp.3710.5 Neck strap attachment pointsp.3910.5.1 Figurep.3910.6 Battery condition LED indicatorp.3910.6.1 Figurep.3910.6.2 Explanationp.3910.7 Power LED indicatorp.4010.7.1 Figurep.4010.7.2 Explanationp.4010.8 Laser pointerp.4010.8.1 Figurep.4010.8.2 Laser warning labelp.4110.8.3 Laser rules and regulationsp.4111 Screen elementsp.4211.1 Figurep.4211.2 Explanationp.4211.3 Status icons and indicatorsp.4211.4 Image overlay informationp.4312 Navigating the menu systemp.4412.1 Generalp.4412.2 Navigating using the joystickp.4413 Handling the camerap.4513.1 Charging the batteryp.4513.1.1 Using the power supply to charge the batteryp.4513.1.2 Using the stand-alone battery charger to charge the batteryp.4513.2 Turning on the camerap.4513.2.1 Procedurep.4513.3 Turning off the camerap.4513.3.1 Procedurep.4513.4 Adjusting the viewfinder’s dioptric correction (sharpness)p.4613.4.1 Figurep.4613.4.2 Procedurep.4613.5 Adjusting the angle of the lensp.4713.5.1 Figurep.4713.6 Adjusting the infrared camera focus manuallyp.4713.6.1 Figurep.4713.6.2 Procedurep.4713.7 Autofocusing the infrared camerap.4813.7.1 Generalp.4813.7.2 Figurep.4813.7.3 Procedurep.4813.8 Continuous autofocusp.4913.8.1 Generalp.4913.8.2 Procedurep.4913.9 Operating the laser pointerp.4913.9.1 Figurep.5013.9.2 Procedurep.5013.10 Using the digital zoom functionp.5013.10.1 Generalp.5013.10.2 Figurep.5113.10.3 Procedurep.5113.11 Assigning functions to the programmable buttonsp.5113.11.1 Generalp.5113.11.2 Procedurep.5213.12 Using the camera lamp as a flashp.5213.12.1 Generalp.5213.12.2 Procedurep.5213.13 Changing lensesp.5213.14 Using the close-up lensp.5613.14.1 Generalp.5613.14.2 Attaching the close-up lensp.5613.14.3 Removing the close-up lensp.5813.15 Calibrating the compassp.6013.15.1 Procedurep.6014 Saving and working with imagesp.6114.1 About image filesp.6114.1.1 Generalp.6114.1.2 File-naming conventionp.6114.1.3 Image capacityp.6114.1.4 About UltraMaxp.6114.2 Saving an imagep.6114.2.1 Generalp.6114.2.2 Procedurep.6214.3 Previewing an imagep.6214.3.1 Generalp.6214.3.2 Procedurep.6214.4 Opening a saved imagep.6214.4.1 Generalp.6214.4.2 Procedurep.6214.5 Editing a saved imagep.6314.5.1 Generalp.6314.5.2 Procedurep.6314.5.3 Related topicsp.6314.6 Creating a PDF report in the camerap.6314.6.1 Generalp.6314.6.2 Naming conventionp.6414.6.3 Procedurep.6414.7 Deleting an imagep.6414.7.1 Generalp.6414.7.2 Procedurep.6414.8 Deleting multiple imagesp.6414.8.1 Generalp.6414.8.2 Procedurep.6414.9 Deleting all imagesp.6514.9.1 Generalp.6514.9.2 Procedurep.6514.10 Resetting the image counterp.6514.10.1 Generalp.6514.10.2 Procedurep.6515 Achieving a good imagep.6715.1 Generalp.6715.2 Adjusting the infrared camera focusp.6715.3 Adjusting the infrared imagep.6715.3.1 Generalp.6715.3.2 Example 1p.6815.3.3 Example 2p.6815.3.4 Manual adjustment in Level, Span modep.6915.3.5 Manual adjustment in Level, Max, Min modep.6915.4 Changing the temperature rangep.6915.4.1 Generalp.6915.4.2 Procedurep.6915.5 Changing the color palettep.7015.5.1 Generalp.7015.5.2 Procedurep.7115.6 Changing the object parametersp.7115.7 Calibrating the camerap.7215.7.1 Generalp.7215.7.2 Manual calibrationp.7215.8 Hiding all overlayp.7215.8.1 Generalp.7215.8.2 Procedurep.7316 Working with image modesp.7416.1 Generalp.7416.2 Image examplesp.7416.3 Selecting the image modep.7517 Working with measurement toolsp.7617.1 Generalp.7617.2 Adding/removing measurement toolsp.7617.3 Working with user presetsp.7617.3.1 Generalp.7617.3.2 Procedurep.7617.4 Resizing or moving a measurement toolp.7717.4.1 Generalp.7717.4.2 Procedurep.7717.5 Changing object parametersp.7817.5.1 Generalp.7817.5.2 Types of parametersp.7817.5.3 Recommended valuesp.7917.5.4 Procedurep.7917.5.5 Related topicsp.8017.6 Displaying values in the result table and displaying a graphp.8017.6.1 Generalp.8017.6.2 Procedurep.8117.7 Creating and setting up a difference calculationp.8117.7.1 Generalp.8117.7.2 Procedurep.8117.8 Setting a measurement alarmp.8217.8.1 Generalp.8217.8.2 Types of alarmp.8217.8.3 Alarm signalsp.8217.8.4 Procedurep.8318 Working with color alarms and isothermsp.8518.1 Color alarmsp.8518.1.1 Generalp.8518.1.2 Image examplesp.8518.2 Setting up above, below, and interval alarmsp.8618.3 Building isothermsp.8718.3.1 About the Condensation alarmp.8718.3.2 About the Insulation alarmp.8718.3.3 Setting up condensation and insulation alarmsp.8719 Annotating imagesp.8819.1 Generalp.8819.2 Adding a notep.8819.2.1 Generalp.8819.2.2 Procedurep.8819.3 Adding a tablep.8819.3.1 Generalp.8819.3.2 Procedurep.8919.4 Adding a voice annotationp.8919.4.1 Generalp.8919.4.2 Procedurep.9019.5 Adding a sketchp.9019.5.1 Generalp.9019.5.2 Procedurep.9020 Programming the camera (time lapse)p.9220.1 Generalp.9220.2 Procedurep.9221 Recording video clipsp.9321.1 Generalp.9321.2 Procedurep.9322 Screening alarmp.9422.1 Generalp.9422.2 Procedurep.9423 Pairing Bluetooth devicesp.9523.1 Generalp.9523.2 Procedurep.9524 Configuring Wi-Fip.9624.1 Generalp.9624.2 Setting up a wireless access point (most common use)p.9624.3 Connecting the camera to a WLAN (less common use)p.9625 Changing settingsp.9725.1 Generalp.9725.1.1 Define user presetsp.9725.1.2 Camera temperature rangep.9725.1.3 Save options & storagep.9725.1.4 Programmable buttonsp.9825.1.5 Device settingsp.9925.2 Procedurep.10126 Technical datap.10226.1 Online field-of-view calculatorp.10226.2 Note about technical datap.10226.3 Note about authoritative versionsp.10226.4 FLIR T1020 12°p.10326.5 FLIR T1020 28°p.11026.6 FLIR T1020 45°p.11726.7 FLIR T1020 28° and 12°p.12426.8 FLIR T1020 28° and 45°p.13126.9 FLIR T1020 28°, 12°, and 45°p.13826.10 FLIR T1030sc 12°p.14526.11 FLIR T1030sc 28°p.15226.12 FLIR T1030sc 45°p.15926.13 FLIR T1040 12°p.16626.14 FLIR T1040 28°p.17326.15 FLIR T1040 45°p.18026.16 FLIR T1050sc 12°p.18726.17 FLIR T1050sc 28°p.19426.18 FLIR T1050sc 45°p.20126.19 IR lens, f=36 mm (28°) with casep.20826.20 Close-up lens 3× (51 µm) with casep.21026.21 IR lens f=21.2 mm (45°) with casep.21126.22 IR lens f=83.4 mm (12°) with casep.21326.23 FLIR T10xx SC kitp.21527 Mechanical drawingsp.21728 Digital I/O pin configurationp.22528.1 Pin configuration for the Digital I/O connector on the HSI boxp.22529 Digital I/O connection diagramp.22630 CE Declaration of conformityp.22831 Cleaning the camerap.23031.1 Camera housing, cables, and other itemsp.23031.1.1 Liquidsp.23031.1.2 Equipmentp.23031.1.3 Procedurep.23031.2 Infrared lensp.23031.2.1 Liquidsp.23031.2.2 Equipmentp.23031.2.3 Procedurep.23031.3 Infrared detectorp.23131.3.1 Generalp.23131.3.2 Procedurep.23132 Application examplesp.23232.1 Moisture & water damagep.23232.1.1 Generalp.23232.1.2 Figurep.23232.2 Faulty contact in socketp.23232.2.1 Generalp.23232.2.2 Figurep.23332.3 Oxidized socketp.23332.3.1 Generalp.23332.3.2 Figurep.23332.4 Insulation deficienciesp.23432.4.1 Generalp.23432.4.2 Figurep.23432.5 Draftp.23532.5.1 Generalp.23532.5.2 Figurep.23533 About FLIR Systemsp.23733.1 More than just an infrared camerap.23833.2 Sharing our knowledgep.23833.3 Supporting our customersp.23934 Glossaryp.24035 Thermographic measurement techniquesp.24335.1 Introductionp.24335.2 Emissivityp.24335.2.1 Finding the emissivity of a samplep.24335.3 Reflected apparent temperaturep.24735.4 Distancep.24735.5 Relative humidityp.24735.6 Other parametersp.24736 History of infrared technologyp.24837 Theory of thermographyp.25137.1 Introductionp.25137.2 The electromagnetic spectrump.25137.3 Blackbody radiationp.25137.3.1 Planck’s lawp.25237.3.2 Wien’s displacement lawp.25337.3.3 Stefan-Boltzmann's lawp.25437.3.4 Non-blackbody emittersp.25537.4 Infrared semi-transparent materialsp.25738 The measurement formulap.25839 Emissivity tablesp.26239.1 Referencesp.26239.2 Tablesp.262
Page 14 of the Flir T1020 user manual
Page 14 · click to enlarge
Page 14
Page 14 of the Flir T1020 user manual
Page 15 of the Flir T1020 user manual — 1.3 Changes to registry
Page 15 · click to enlarge
Page 15

Disclaimers 1

1.1 Legal disclaimer

All products manufactured by FLIR Systems are warranted against defective materials and workmanship for a period of one (1) year from the delivery date of the original pur- chase, provided such products have been under normal storage, use and service, and in accordance with FLIR Systems instruction.

Uncooled handheld infrared cameras manufactured by FLIR Systems are warranted against defective materials and workmanship for a period of two (2) years from the delivery date of the original purchase, provided such products have been under normal storage, use and service, and in accordance with FLIR Systems instruction, and provided that the camera has been registered within 60 days of original purchase.

Detectors for uncooled handheld infrared cameras manufactured by FLIR Systems are warranted against defective materials and workmanship for a period of ten (10) years from the delivery date of the original purchase, provided such products have been under normal storage, use and service, and in accordance with FLIR Systems instruction, and provided that the camera has been registered within 60 days of original purchase.

Products which are not manufactured by FLIR Systems but included in systems delivered by FLIR Systems to the original purchaser, carry the warranty, if any, of the particular sup- plier only. FLIR Systems has no responsibility whatsoever for such products.

The warranty extends only to the original purchaser and is not transferable. It is not appli- cable to any product which has been subjected to misuse, neglect, accident or abnormal conditions of operation. Expendable parts are excluded from the warranty.

In the case of a defect in a product covered by this warranty the product must not be fur- ther used in order to prevent additional damage. The purchaser shall promptly report any defect to FLIR Systems or this warranty will not apply.

FLIR Systems will, at its option, repair or replace any such defective product free of charge if, upon inspection, it proves to be defective in material or workmanship and provided that it is returned to FLIR Systems within the said one-year period.

FLIR Systems has no other obligation or liability for defects than those set forth above.

No other warranty is expressed or implied. FLIR Systems specifically disclaims the implied warranties of merchantability and fitness for a particular purpose.

FLIR Systems shall not be liable for any direct, indirect, special, incidental or consequen- tial loss or damage, whether based on contract, tort or any other legal theory.

This warranty shall be governed by Swedish law.

Any dispute, controversy or claim arising out of or in connection with this warranty, shall be finally settled by arbitration in accordance with the Rules of the Arbitration Institute of the Stockholm Chamber of Commerce. The place of arbitration shall be Stockholm. The lan- guage to be used in the arbitral proceedings shall be English.

1.2 Usage statistics

FLIR Systems reserves the right to gather anonymous usage statistics to help maintain and improve the quality of our software and services.

1.3 Changes to registry

The registry entry HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Lsa \LmCompatibilityLevel will be automatically changed to level 2 if the FLIR Camera Monitor service detects a FLIR camera connected to the computer with a USB cable. The

Page 16 of the Flir T1020 user manual — 1.7 Patents
Page 16 · click to enlarge
Page 16

Disclaimers 1

modification will only be executed if the camera device implements a remote network serv- ice that supports network logons.

1.4 U.S. Government Regulations

This product may be subject to U.S. Export Regulations. Please send any inquiries to ex- portquestions@flir.com.

1.5 Copyright

© 2016, FLIR Systems, Inc. All rights reserved worldwide. No parts of the software includ- ing source code may be reproduced, transmitted, transcribed or translated into any lan- guage or computer language in any form or by any means, electronic, magnetic, optical, manual or otherwise, without the prior written permission of FLIR Systems.

The documentation must not, in whole or part, be copied, photocopied, reproduced, trans- lated or transmitted to any electronic medium or machine readable form without prior con- sent, in writing, from FLIR Systems.

Names and marks appearing on the products herein are either registered trademarks or trademarks of FLIR Systems and/or its subsidiaries. All other trademarks, trade names or company names referenced herein are used for identification only and are the property of their respective owners.

1.6 Quality assurance

The Quality Management System under which these products are developed and manu- factured has been certified in accordance with the ISO 9001 standard.

FLIR Systems is committed to a policy of continuous development; therefore we reserve the right to make changes and improvements on any of the products without prior notice.

1.7 Patents

One or several of the following patents and/or design patents may apply to the products and/or features. Additional pending patents and/or pending design patents may also apply.

000279476-0001; 000439161; 000499579-0001; 000653423; 000726344; 000859020; 001106306-0001; 001707738; 001707746; 001707787; 001776519; 001954074; 002021543; 002058180; 002249953; 002531178; 0600574-8; 1144833; 1182246; 1182620; 1285345; 1299699; 1325808; 1336775; 1391114; 1402918; 1404291; 1411581; 1415075; 1421497; 1458284; 1678485; 1732314; 2106017; 2107799; 2381417; 3006596; 3006597; 466540; 483782; 484155; 4889913; 5177595; 60122153.2; 602004011681.5-08; 6707044; 68657; 7034300; 7110035; 7154093; 7157705; 7237946; 7312822; 7332716; 7336823; 7544944; 7667198; 7809258 B2; 7826736; 8,153,971; 8,823,803; 8,853,631; 8018649 B2; 8212210 B2; 8289372; 8354639 B2; 8384783; 8520970; 8565547; 8595689; 8599262; 8654239; 8680468; 8803093; D540838; D549758; D579475; D584755; D599,392; D615,113; D664,580; D664,581; D665,004; D665,440; D677298; D710,424 S; D718801; DI6702302-9; DI6903617-9; DI7002221-6; DI7002891-5; DI7002892-3; DI7005799-0; DM/057692; DM/061609; EP 2115696 B1; EP2315433; SE 0700240-5; US 8340414 B2; ZL 201330267619.5; ZL01823221.3; ZL01823226.4; ZL02331553.9; ZL02331554.7; ZL200480034894.0; ZL200530120994.2; ZL200610088759.5; ZL200630130114.4; ZL200730151141.4; ZL200730339504.7; ZL200820105768.8; ZL200830128581.2; ZL200880105236.4; ZL200880105769.2; ZL200930190061.9; ZL201030176127.1; ZL201030176130.3; ZL201030176157.2; ZL201030595931.3; ZL201130442354.9; ZL201230471744.3; ZL201230620731.8.

Page 17 of the Flir T1020 user manual — 1.8.3 Fonts (DejaVu)
Page 17 · click to enlarge
Page 17

Disclaimers 1

1.8 Third-party licenses

1.8.1 GNU Lesser General Public License (LGPL)

http://www.gnu.org/licenses/lgpl-2.1.en.html

(Retrieved May 27, 2015)

1.8.2 Fonts (Source Han Sans)

https://github.com/adobe-fonts/source-han-sans/blob/master/LICENSE.txt

(Retrieved May 27, 2015)

1.8.3 Fonts (DejaVu)

http://dejavu-fonts.org/wiki/License

(Retrieved May 27, 2015)

Page 18 of the Flir T1020 user manual — WARNING
Page 18 · click to enlarge
Page 18

Safety information 2

WARNING

Applicability: Class B digital devices.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular in- stallation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

WARNING

Applicability: Digital devices subject to 15.19/RSS-247 issue 1.

1. this device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation.

WARNING

This device is granted pursuant to the Japanese Radio Law (電波法) and the Japanese Telecommunica- tions Business Law (電気通信事業法). This device should not be modified (otherwise the granted desig- nation number will become invalid)

WARNING

Applicability: Digital devices subject to 15.21.

WARNING

Applicability: Digital devices subject to 2.1091/2.1093/OET Bulletin 65.

Radiofrequency radiation exposure Information: The radiated output power of the device is below the FCC/IC radio frequency exposure limits. Nevertheless, the device shall be used in such a manner that the potential for human contact during normal operation is minimized.

WARNING

Applicability: Cameras with one or more laser pointers.

Do not look directly into the laser beam. The laser beam can cause eye irritation.

WARNING

Applicability: Cameras with one or more batteries.

Do not disassemble or do a modification to the battery. The battery contains safety and protection devices which, if damage occurs, can cause the battery to become hot, or cause an explosion or an ignition.

Page 19 of the Flir T1020 user manual — CAUTION
Page 19 · click to enlarge
Page 19

Safety information 2

WARNING

Applicability: Cameras with one or more batteries.

If there is a leak from the battery and you get the fluid in your eyes, do not rub your eyes. Flush well with water and immediately get medical care. The battery fluid can cause injury to your eyes if you do not do this.

WARNING

Applicability: Cameras with one or more batteries.

Do not continue to charge the battery if it does not become charged in the specified charging time. If you continue to charge the battery, it can become hot and cause an explosion or ignition. Injury to persons can occur.

WARNING

Applicability: Cameras with one or more batteries.

Only use the correct equipment to remove the electrical power from the battery. If you do not use the cor- rect equipment, you can decrease the performance or the life cycle of the battery. If you do not use the correct equipment, an incorrect flow of current to the battery can occur. This can cause the battery to be- come hot, or cause an explosion. Injury to persons can occur.

WARNING

Make sure that you read all applicable MSDS (Material Safety Data Sheets) and warning labels on con- tainers before you use a liquid. The liquids can be dangerous. Injury to persons can occur.

CAUTION

Do not point the infrared camera (with or without the lens cover) at strong energy sources, for example, devices that cause laser radiation, or the sun. This can have an unwanted effect on the accuracy of the camera. It can also cause damage to the detector in the camera.

CAUTION

Do not use the camera in temperatures more than +50°C (+122°F), unless other information is specified in the user documentation or technical data. High temperatures can cause damage to the camera.

CAUTION

Applicability: Cameras with one or more laser pointers.

To prevent damage, put the protective cap on the laser pointer when you do not operate the laser pointer. Damage to the laser pointer can occur if you do not do this.

CAUTION

Applicability: Cameras with one or more batteries.

Do not attach the batteries directly to a car’s cigarette lighter socket, unless FLIR Systems supplies a spe- cific adapter to connect the batteries to a cigarette lighter socket. Damage to the batteries can occur.

CAUTION

Applicability: Cameras with one or more batteries.

Do not connect the positive terminal and the negative terminal of the battery to each other with a metal object (such as wire). Damage to the batteries can occur.

Page 20 of the Flir T1020 user manual — CAUTION
Page 20 · click to enlarge
Page 20

Safety information 2

CAUTION

Applicability: Cameras with one or more batteries.

Do not get water or salt water on the battery, or permit the battery to become wet. Damage to the batteries can occur.

CAUTION

Applicability: Cameras with one or more batteries.

Do not make holes in the battery with objects. Damage to the battery can occur.

CAUTION

Applicability: Cameras with one or more batteries.

Do not hit the battery with a hammer. Damage to the battery can occur.

CAUTION

Applicability: Cameras with one or more batteries.

Do not put your foot on the battery, hit it or cause shocks to it. Damage to the battery can occur.

CAUTION

Applicability: Cameras with one or more batteries.

Do not put the batteries in or near a fire, or into direct sunlight. When the battery becomes hot, the built-in safety equipment becomes energized and can stop the battery charging procedure. If the battery be- comes hot, damage can occur to the safety equipment and this can cause more heat, damage or ignition of the battery.

CAUTION

Applicability: Cameras with one or more batteries.

Do not put the battery on a fire or increase the temperature of the battery with heat. Damage to the battery and injury to persons can occur.

CAUTION

Applicability: Cameras with one or more batteries.

Do not put the battery on or near fires, stoves, or other high-temperature locations. Damage to the battery and injury to persons can occur.

CAUTION

Applicability: Cameras with one or more batteries.

Do not solder directly onto the battery. Damage to the battery can occur.

CAUTION

Applicability: Cameras with one or more batteries.

Do not use the battery if, when you use, charge, or put the battery in storage, there is an unusual smell from the battery, the battery feels hot, changes color, changes shape, or is in an unusual condition. Speak with your sales office if one or more of these problems occurs. Damage to the battery and injury to per- sons can occur.

Page 21 of the Flir T1020 user manual — CAUTION
Page 21 · click to enlarge
Page 21

Safety information 2

CAUTION

Applicability: Cameras with one or more batteries.

Only use a specified battery charger when you charge the battery. Damage to the battery can occur if you do not do this.

CAUTION

Applicability: Cameras with one or more batteries.

Only use a specified battery for the camera. Damage to the camera and the battery can occur if you do not do this.

CAUTION

Applicability: Cameras with one or more batteries.

The temperature range through which you can charge the battery is ±0°C to +45°C (+32°F to +113°F), unless other information is specified in the user documentation or technical data. If you charge the battery at temperatures out of this range, it can cause the battery to become hot or to break. It can also decrease the performance or the life cycle of the battery.

CAUTION

Applicability: Cameras with one or more batteries.

The temperature range through which you can remove the electrical power from the battery is -15°C to +50°C (+5°F to +122°F), unless other information is specified in the user documentation or technical data. If you operate the battery out of this temperature range, it can decrease the performance or the life cycle of the battery.

CAUTION

Applicability: Cameras with one or more batteries.

When the battery is worn, apply insulation to the terminals with adhesive tape or equivalent materials be- fore you discard it. Damage to the battery and injury to persons can occur if you do not do this.

CAUTION

Applicability: Cameras with one or more batteries.

Remove any water or moisture on the battery before you install it. Damage to the battery can occur if you do not do this.

CAUTION

Do not apply solvents or equivalent liquids to the camera, the cables, or other items. Damage to the bat- tery and injury to persons can occur.

CAUTION

Be careful when you clean the infrared lens. The lens has an anti-reflective coating which is easily dam- aged. Damage to the infrared lens can occur.

CAUTION

Do not use too much force to clean the infrared lens. This can cause damage to the anti-reflective coating.

Page 22 of the Flir T1020 user manual — CAUTION
Page 22 · click to enlarge
Page 22

Safety information 2

NOTE

The encapsulation rating is only applicable when all the openings on the camera are sealed with their cor- rect covers, hatches, or caps. This includes the compartments for data storage, batteries, and connectors.

CAUTION

Applicability: Cameras with a viewfinder.

Make sure that the beams from the intensive energy sources do not go into the viewfinder. The beams can cause damage to the camera. This includes the devices that emit laser radiation, or the sun.

Page 23 of the Flir T1020 user manual — 3.7 Important note about this manual
Page 23 · click to enlarge
Page 23

Notice to user 3

3.1 User-to-user forums

Exchange ideas, problems, and infrared solutions with fellow thermographers around the world in our user-to-user forums. To go to the forums, visit:

http://www.infraredtraining.com/community/boards/

3.2 Calibration

We recommend that you send in the camera for calibration once a year. Contact your local sales office for instructions on where to send the camera.

3.3 Accuracy

For very accurate results, we recommend that you wait 5 minutes after you have started the camera before measuring a temperature.

3.4 Disposal of electronic waste

As with most electronic products, this equipment must be disposed of in an environmen- tally friendly way, and in accordance with existing regulations for electronic waste.

Please contact your FLIR Systems representative for more details.

3.5 Training

To read about infrared training, visit:

  • <a href="http://www.infraredtraining.com" rel="nofollow noopener" target="_blank">http://www.infraredtraining.com</a>
  • <a href="http://www.irtraining.com" rel="nofollow noopener" target="_blank">http://www.irtraining.com</a>
  • <a href="http://www.irtraining.eu" rel="nofollow noopener" target="_blank">http://www.irtraining.eu</a>

3.6 Documentation updates

Our manuals are updated several times per year, and we also issue product-critical notifi- cations of changes on a regular basis.

To access the latest manuals, translations of manuals, and notifications, go to the Down- load tab at:

http://support.flir.com

It only takes a few minutes to register online. In the download area you will also find the lat- est releases of manuals for our other products, as well as manuals for our historical and obsolete products.

3.7 Important note about this manual

FLIR Systems issues generic manuals that cover several cameras within a model line.

This means that this manual may contain descriptions and explanations that do not apply to your particular camera model.

Page 24 of the Flir T1020 user manual — Notice to user 3
Page 24 · click to enlarge
Page 24

Notice to user 3

3.8 Note about authoritative versions

The authoritative version of this publication is English. In the event of divergences due to translation errors, the English text has precedence.

Any late changes are first implemented in English.

Page 25 of the Flir T1020 user manual — 4.2 Submitting a question
Page 25 · click to enlarge
Page 25

Customer help 4

Flir T1020 — Customer help 4 diagram (page 25)
Fig. 2 · Customer help 4

4.1 General

For customer help, visit:

http://support.flir.com

4.2 Submitting a question

To submit a question to the customer help team, you must be a registered user. It only takes a few minutes to register online. If you only want to search the knowledgebase for existing questions and answers, you do not need to be a registered user.

When you want to submit a question, make sure that you have the following information to hand:

  • The camera model
  • The camera serial number
  • The communication protocol, or method, between the camera and your device (for example, HDMI, Ethernet, USB, or FireWire)
Page 26 of the Flir T1020 user manual — 4.3 Downloads
Page 26 · click to enlarge
Page 26

Customer help 4

  • Device type (PC/Mac/iPhone/iPad/Android device, etc.)
  • Version of any programs from FLIR Systems
  • Full name, publication number, and revision number of the manual

4.3 Downloads

On the customer help site you can also download the following, when applicable for the product:

  • Firmware updates for your infrared camera.
  • Program updates for your PC/Mac software.
  • Freeware and evaluation versions of PC/Mac software.
  • User documentation for current, obsolete, and historical products.
  • Mechanical drawings (in *.dxf and *.pdf format).
  • Cad data models (in *.stp format).
  • Application stories.
  • Technical datasheets.
  • Product catalogs.
Page 27 of the Flir T1020 user manual — 5.2 Key benefits
Page 27 · click to enlarge
Page 27

Introduction 5

Flir T1020 — Introduction 5 diagram (page 27)
Fig. 3 · Introduction 5

5.1 General description

The FLIR T10xx series is designed for the expert requiring the highest performance and the latest technology available. The camera series combines excellent ergonomics and feature-rich flexibility with superior image quality of 1024 × 768 pixel infrared resolution. High accuracy and sensitivity together with radiometric recording and streaming options make the FLIR T10xx series well suited for advanced research and development.

5.2 Key benefits

  • Tailor made for research and development: The FLIR T10xx series has high accuracy and high sensitivity, to accurately measure the smallest temperature differences. With real-time radiometric recording by the camera, it is possible to capture fast events on the camera’s SD card for further analysis by the supplied analysis software.
  • Flexible and feature rich: A wide variety of measuring and analysis functions makes the camera flexible for your every need. Two programmable buttons provide easy access to favorite functions.
  • Highest performance with the latest technology: The FLIR T10xx series is equipped with the innovative Multi Spectral Dynamic Imaging (MSX) feature, which produces an image richer in detail than ever before. With its continuous autofocus, the FLIR T10xx series is a fully automatic infrared camera.
Page 28 of the Flir T1020 user manual — 6.1 Procedure
Page 28 · click to enlarge
Page 28

Quick start guide 6

6.1 Procedure

Follow this procedure:

1. Put a battery into the battery compartment. 2. Charge the battery for 4 hours before starting the camera for the first time. 3. Insert a memory card into the card slot.
4. Push the On/off button

to turn on the camera. 5. Aim the camera toward the object of interest. 6. Adjust the focus.

7. Push the Save button fully down to save an image. 8. Go to http://support.flir.com/tools and download FLIR Tools. 9. Install FLIR Tools on your computer. 10. Start FLIR Tools. 11. Connect the camera to the computer using a USB cable. 12. Import the images into FLIR Tools. 13. Select one or more images. 14. Click Generate report . 15. Click Export to export the report as a PDF file. 16. Send the PDF report to your client.
Page 29 of the Flir T1020 user manual — 7.1 Introduction
Page 29 · click to enlarge
Page 29

About FLIR Tools/Tools+ 7

7.1 Introduction

FLIR Tools is available as a free download at http://support.flir.com/tools FLIR Tools+ pro- vides extended functionality to the standard FLIR Tools software. A license card for FLIR Tools+ is included with the FLIR T10xx camera.

Flir T1020 — 7.1 Introduction diagram (page 29)
Fig. 4 · 7.1 Introduction

FLIR Tools/Tools+ is a software suite specifically designed to provide an easy way to up- date your camera and create inspection reports.

Examples of what you can do in FLIR Tools/Tools+ include the following:

  • Import images from your camera to your computer.
  • Apply filters when searching for images.
  • Lay out, move, and resize measurement tools on any infrared image.
  • Group and ungroup files.
  • Create panoramas by stitching several smaller images into a larger one.
  • Create PDF imagesheets of any images of your choice.
  • Add headers, footers, and logos to imagesheets.
  • Create PDF/Microsoft Word reports for images of your choice.
  • Add headers, footers, and logos to reports.
  • Update your camera with the latest firmware.

For more information, refer to the User’s manual for FLIR Tools/Tools+.

Page 30 of the Flir T1020 user manual — About FLIR Tools/Tools+ 7
Page 30 · click to enlarge
Page 30

About FLIR Tools/Tools+ 7

7.2 Workflow

7.2.1 General

Flir T1020 — About FLIR Tools/Tools+ 7 diagram (page 30)
Fig. 5 · About FLIR Tools/Tools+ 7

When you carry out an infrared inspection you follow a typical workflow. This section gives an example of an infrared inspection workflow.

1. Use your camera to take your infrared images and/or digital photos. 2. Connect your camera to a PC using a USB connector. 3. Import the images from the camera into FLIR Tools/Tools+. 4. Do one of the following:
  • Create a PDF imagesheet in FLIR Tools.
  • Create a PDF report in FLIR Tools.
  • Create a non-radiometric Microsoft Word report in FLIR Tools+.
  • Create a radiometric Microsoft Word report in FLIR Tools+.
5. Send the report to your client as an attachment to an e-mail.
Page 31 of the Flir T1020 user manual — 8.2 System overview
Page 31 · click to enlarge
Page 31

Using the high-speed interface (HSI) 8

8.1 General

The high-speed interface (HSI) is included in the FLIR T10xx SC kit. The high-speed inter- face enables streaming of live video from the FLIR T10xx camera to a PC running the FLIR ResearchIR Max software. The high-speed interface is primarily intended for R&D usage and development purposes. As an example, the camera can capture and stream very rap- id processes, which cannot be perceived by the human eye, for later processing and anal- ysis in the PC software. The streamed video is fully radiometric and uncompressed.

8.2 System overview

8.2.1 Figure

Flir T1020 — 8.2 System overview diagram (page 31)
Fig. 6 · 8.2 System overview
1. PC running FLIR ResearchIR Max (a download card with a printed license key is included with the HSI box). 2. USB 3 connection. 3. USB 3 cable connector. 4. Optional digital I/O connector. 5. HSI box
Page 32 of the Flir T1020 user manual — 8.5 Digital I/O
Page 32 · click to enlarge
Page 32

Using the high-speed interface (HSI) 8

6. High-speed LVDS connection. 7. High-speed interface cable connector. 8. FLIR T10xx camera, optionally with a close-up lens. 9. Object of study.

8.3 Quick start guide

Follow this procedure:

1. Go to http://support.flir.com/rir4 and download FLIR ResearchIR Max. 2. Install FLIR ResearchIR Max. 3. Start FLIR ResearchIR Max.

When asked for the license key, enter the license key that is printed on the FLIR Re- searchIR Max download card. The card is included with the HSI box. 4. Connect the HSI box to the computer using the provided USB 3 cable. 5. Connect the camera to the HSI box using the integrated high-speed interface cable. 6. Start the camera. This displays a start-up dialog box in FLIR ResearchIR Max. If the start-up dialog box is not displayed, go to View > Startup Dialog. 7. In the start-up dialog box, click the camera you want to connect to.

For more information about the installation and connection processes, see the FLIR Re- searchIR Max manual.

8.4 HSI box indicator LED

Indicator LED status Explanation

The indicator LED displays a continuous blue light. The HSI box is operational, and video data is now continuously streamed to the computer.

The indicator LED displays a flashing blue light, with a period time of about 1 second.

The HSI box is connected to the computer, but the link between the camera and the box is not up. Ei- ther the cable to the camera is not correctly con- nected or there is another error on the link.

The indicator LED displays a continuous blue light with short interrupts.

Each interrupt in the continuos light indicates a bit error in the video data stream.

8.5 Digital I/O

For information about the optional Digital I/O connection, see sections 28 Digital I/O pin configuration, page 211 and 29 Digital I/O connection diagram, page 212.

Page 33 of the Flir T1020 user manual — 9.2 Figure
Page 33 · click to enlarge
Page 33

A note about ergonomics 9

9.1 General

To prevent strain-related injuries, it is important that you hold the camera ergonomically correctly. This section gives advice and examples on how to hold the camera.

Note

  • Always tilt the touch-screen LCD to suit your work position.
  • When you hold the camera, make sure that you support the optics housing with your left hand too. This decreases the strain on your right hand.
  • Always use the supplied neck strap. See section 10.5 Neck strap attachment points , page 25.

9.2 Figure

Flir T1020 — 9.2 Figure diagram (page 33)
Fig. 7 · 9.2 Figure
Page 34 of the Flir T1020 user manual — 10.1.2 Explanation
Page 34 · click to enlarge
Page 34

Camera parts 10

10.1 View from the right

10.1.1 Figure

Flir T1020 — 10.1 View from the right diagram (page 34)
Fig. 8 · 10.1 View from the right

10.1.2 Explanation

1. Knob to change the dioptric correction for the viewfinder. 2. Hand strap. 3. Digital zoom button.
4. Save button (push fully down).

button half-way down. To enable the autofocus function of the Save button, select

(Settings) > Save options & storage > Save button half-press = Autofocus.

Page 35 of the Flir T1020 user manual — 10.2.2 Explanation
Page 35 · click to enlarge
Page 35

Camera parts 10

10.2 View from the left

10.2.1 Figure

Flir T1020 — Camera parts 10 diagram (page 35)
Fig. 9 · Camera parts 10

10.2.2 Explanation

1. Digital camera. 2. Camera lamp. 3. Laser pointer.
4. Infrared lens. 5. Camera lamp. 6. Digital camera. 7. Focusing ring.
8. Programmable button . 9. Button to operate the laser pointer.
Page 36 of the Flir T1020 user manual — Note
Page 36 · click to enlarge
Page 36

Camera parts 10

10.3 View from the bottom

10.3.1 Figure

Flir T1020 — Camera parts 10 diagram (page 36)
Fig. 10 · Camera parts 10

10.3.2 Explanation

1. Memory card. 2. LED indicator showing that the memory card is busy.

Note

  • Do not eject the memory card when this LED is flashing.
  • Do not connect the camera to a computer when this LED is flashing.
3. USB Micro B cable (to connect the camera to a computer). 4. HDMI cable (for digital video output). 5. Battery condition LED indicator. 6. Power supply cable (to power the camera and charge the battery). 7. High-speed interface cable. 8. Tripod mount. 9. Button to release the lens. 10. Latch to release the battery.
Page 37 of the Flir T1020 user manual — 10.4.2 Explanation
Page 37 · click to enlarge
Page 37

Camera parts 10

10.4 View from the rear

10.4.1 Figure

Flir T1020 — Camera parts 10 diagram (page 37)
Fig. 11 · Camera parts 10

10.4.2 Explanation

1. Sensor that adjusts the touch-screen LCD intensity automatically.
2. button. Function:
  • Push to switch between touch-screen LCD mode and viewfinder mode.
3. Viewfinder.
4. Programmable button .
5. Joystick with push-button functionality. Function:
  • Move the joystick left/right or up/down to navigate in menus, submenus, and dialog boxes, and to change values in dialog boxes.
  • Push the joystick to confirm changes and settings in menus and dialog boxes.
6. Back button . Function:
  • Push to leave dialog boxes and to go back into the menu system.
7. Camera lamp button . Function:
  • Push to turn on or off the camera lamp.

(Settings) > Device settings > Set up camera > Lamp & laser > Enable lamp & laser.

Page 38 of the Flir T1020 user manual — Camera parts 10
Page 38 · click to enlarge
Page 38

Camera parts 10

8. button. Function:
  • Push to switch between automatic and manual image adjustment mode.
9. Image archive button . Function:
  • Push to open the image archive.
  • Push and hold for more than 2 seconds to perform a manual calibration.
10. Touch-screen LCD. 11. Power indicator.
12. On/off button

. Function:

  • Push and release to turn on the camera.
  • Push and hold for more than 0.5 second to turn off the camera.
Page 39 of the Flir T1020 user manual — 10.6.2 Explanation
Page 39 · click to enlarge
Page 39

Camera parts 10

10.5 Neck strap attachment points

10.5.1 Figure

Flir T1020 — Camera parts 10 diagram (page 39)
Fig. 12 · Camera parts 10

10.6 Battery condition LED indicator

10.6.1 Figure

Flir T1020 — 10.6 Battery condition LED indicator diagram (page 39)
Fig. 13 · 10.6 Battery condition LED indicator

10.6.2 Explanation

Type of signal Explanation

The green LED flashes twice per second. The battery is being charged.

The green LED glows continuously. The battery is fully charged.

Page 40 of the Flir T1020 user manual — WARNING
Page 40 · click to enlarge
Page 40

Camera parts 10

10.7 Power LED indicator

10.7.1 Figure

Flir T1020 — Camera parts 10 diagram (page 40)
Fig. 14 · Camera parts 10

10.7.2 Explanation

Type of signal Explanation

The LED is off. The camera is off.

The LED is blue. The camera is on.

10.8 Laser pointer

10.8.1 Figure

Flir T1020 — 10.8 Laser pointer diagram (page 40)
Fig. 15 · 10.8 Laser pointer

Figure 10.1 This figure shows the difference in position between the laser pointer and the optical center of the infrared lens.

WARNING

Do not look directly into the laser beam. The laser beam can cause eye irritation.

Page 41 of the Flir T1020 user manual — 10.8.3 Laser rules and regulations
Page 41 · click to enlarge
Page 41

Camera parts 10

Note

  • The symbol

is displayed on the screen when the laser pointer is on.

  • The laser pointer is enabled by a setting. Select

(Settings) > Device settings > Set up camera > Lamp & laser > Enable lamp & laser.

10.8.2 Laser warning label

A laser warning label with the following information is attached to the camera:

10.8.3 Laser rules and regulations

Wavelength: 635 nm. Maximum output power: 1 mW.

This product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007.

Page 42 of the Flir T1020 user manual — 11.3 Status icons and indicators
Page 42 · click to enlarge
Page 42

Screen elements 11

11.1 Figure

Flir T1020 — 11.1 Figure diagram (page 42)
Fig. 16 · 11.1 Figure

11.2 Explanation

1. Programmable button P4. 2. Programmable button P3. 3. Digital zoom factor. 4. Result table. 5. Status icons. 6. Measurement tool (e.g., spotmeter). 7. Temperature scale. 8. Submenu. 9. Main menu. 10. Settings button. 11. Color button. 12. Measurement button. 13. Image mode button. 14. Measurement parameters button. 15. Recording mode button.

11.3 Status icons and indicators

Flir T1020 — 11.3 Status icons and indicators diagram (page 42)
Fig. 17 · 11.3 Status icons and indicators

The camera is connected to a device using USB.

Page 43 of the Flir T1020 user manual — 11.4 Image overlay information
Page 43 · click to enlarge
Page 43

Screen elements 11

A Bluetooth headset is connected.

The GPS indicator.

  • Gray icon: GPS is enabled, but there is no satellite contact.
  • White icon: GPS is enabled, with satellite contact.

External infrared window compensation is enabled.

Compass indicator (part of the image overlay information).

The laser pointer is turned on.

11.4 Image overlay information

The image information consists of items such as date, emissivity, and atmospheric tem- perature. All image information is saved in the image file and can be viewed in the image archive. You can also choose to display selected items as image overlay information. All image overlay information displayed on the live image will also be displayed on saved im- ages. For more information, see sections 25.1.5 Device settings, page 85 and 15.8 Hiding all overlay, page 58.

Flir T1020 — 11.4 Image overlay information diagram (page 43)
Fig. 18 · 11.4 Image overlay information
Page 44 of the Flir T1020 user manual — 12.2 Navigating using the joystick
Page 44 · click to enlarge
Page 44

Navigating the menu system 12

12.1 General

Flir T1020 — 12.1 General diagram (page 44)
Fig. 19 · 12.1 General

The figure above shows the two ways to navigate the menu system in the camera:

  • Using the index finger or a stylus pen specially designed for capacitive touch usage to navigate the menu system (left).
  • Using the joystick to navigate the menu system (right) and the Back button.

You can also use a combination of the two.

In this manual, it is assumed that the joystick is used, but most tasks can also be carried out using the index finger or a stylus pen.

12.2 Navigating using the joystick

You navigate the menu system by using the joystick and the Back button:

  • To display the menu system, push the joystick.
  • To navigate in menus, submenus, and dialog boxes, and to change values in dialog boxes, move the joystick up/down or left/right.
  • To confirm changes and settings in menus and dialog boxes, push the joystick.
  • To leave dialog boxes and to go back in the menu system, push the Back button .
Page 45 of the Flir T1020 user manual — 13.3 Turning off the camera
Page 45 · click to enlarge
Page 45

Handling the camera 13

13.1 Charging the battery

13.1.1 Using the power supply to charge the battery

13.1.1.1 Procedure

Follow this procedure:

1. Connect the power supply cable plug to the power connector on the camera. 2. Connect the power supply mains-electricity plug to a mains socket. 3. It is good practice to disconnect the power supply cable plug when the green light of the battery condition LED indicator is continuous.

13.1.2 Using the stand-alone battery charger to charge the battery

13.1.2.1 Explanation

Type of signal Explanation

The blue LED flashes. The battery is being charged.

The blue LED glows continuously. The battery is fully charged.

13.1.2.2 Procedure

Follow this procedure:

1. Put the battery in the battery charger. 2. Connect the power supply cable plug to the connector on the battery charger. 3. Connect the power supply mains-electricity plug to a mains socket. 4. It is good practice to disconnect the power supply cable plug when the blue LED on the battery charger is glowing continuously.

13.2 Turning on the camera

13.2.1 Procedure

Follow this procedure:

1. To turn on the camera, push and release the On/off button

13.3 Turning off the camera

13.3.1 Procedure

Follow this procedure:

1. To turn off the camera, push and hold the On/off button

for more than 0.5 second.

Page 46 of the Flir T1020 user manual — Note
Page 46 · click to enlarge
Page 46

Handling the camera 13

13.4 Adjusting the viewfinder’s dioptric correction (sharpness)

13.4.1 Figure

Flir T1020 — Handling the camera 13 diagram (page 46)
Fig. 20 · Handling the camera 13

Make sure that the beams from the intensive energy sources do not go into the viewfinder. The beams can cause damage to the camera. This includes the devices that emit laser radiation, or the sun.

13.4.2 Procedure

Follow this procedure:

1. Push the button to switch from touch-screen LCD mode to viewfinder mode. 2. To adjust the viewfinder’s dioptric correction, look through the viewfinder and rotate the adjustment knob clockwise or counter-clockwise for the best sharpness.

Note

  • Maximum dioptric correction: +2.
  • Minimum dioptric correction: –2.
Page 47 of the Flir T1020 user manual — 13.6.2 Procedure
Page 47 · click to enlarge
Page 47

Handling the camera 13

13.5 Adjusting the angle of the lens

13.5.1 Figure

Flir T1020 — Handling the camera 13 diagram (page 47)
Fig. 21 · Handling the camera 13

13.6 Adjusting the infrared camera focus manually

13.6.1 Figure

Flir T1020 — 13.6 Adjusting the infrared camera focus manually diagram (page 47)
Fig. 22 · 13.6 Adjusting the infrared camera focus manually

13.6.2 Procedure

Follow this procedure:

1. Do one of the following:
  • For far focus, rotate the focus ring clockwise (looking at the touch-screen LCD side of the camera).
  • For near focus, rotate the focus ring counter-clockwise (looking at the touch-screen LCD side of the camera).
Page 48 of the Flir T1020 user manual — 13.7.3 Procedure
Page 48 · click to enlarge
Page 48

Handling the camera 13

Note

  • Do not touch the lens surface when you adjust the infrared camera focus manually. If this happens, clean the lens according to the instructions in 31.2 Infrared lens , page 216.
  • The focus ring can be rotated infinitely, but only a certain amount of rotation is needed when focusing.
  • The response of the focus mechanism is progressive, meaning that a faster rotation of the focus ring gives a disproportional higher speed of focus change. This allows for both fine adjustment with a relatively large (but slow) rotation and rapid change with a smaller (but faster) rotation. Furthermore, for a very slow rotation, the lens moves in very small, discrete steps (which you can hear), allowing for a controlled fine adjustment of the focus.

13.7 Autofocusing the infrared camera

13.7.1 General

The infrared camera can be configured to autofocus when you push the Save button half- way down.

13.7.2 Figure

Flir T1020 — 13.7.2 Figure diagram (page 48)
Fig. 23 · 13.7.2 Figure

13.7.3 Procedure

Follow this procedure:

1. To enable the autofocus function of the Save button, select

(Settings) > Save op- tions & storage > Save button half-press = Autofocus. 2. To autofocus, push the Save button half-way down.

Page 49 of the Flir T1020 user manual — 13.9 Operating the laser pointer
Page 49 · click to enlarge
Page 49

Handling the camera 13

13.8 Continuous autofocus

13.8.1 General

The infrared camera can be set up to perform continuous autofocusing.

Note

  • In this mode, the digital camera is used, which means that continuous autofocus will not work in darkness.
  • When continuous autofocus is enabled, it is not possible to manually adjust the focus by rotating the focus ring.
  • To stop continuous autofocus (e.g., to stabilize the focus before saving an image), push the Save button half-way down.

13.8.2 Procedure

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Settings). 3. Push the joystick to display the Settings menu. 4. Select Device settings and push the joystick. 5. Select Continuous autofocus and push the joystick. 6. Select On and push the joystick.

mable buttons. Select

(Settings) > Programmable buttons.

13.9 Operating the laser pointer

WARNING

Do not look directly into the laser beam. The laser beam can cause eye irritation.

(Settings) > Device settings > Lamp & laser > Enable lamp & laser.

Page 50 of the Flir T1020 user manual — 13.10 Using the digital zoom function
Page 50 · click to enlarge
Page 50

Handling the camera 13

13.9.1 Figure

Flir T1020 — Handling the camera 13 diagram (page 50)
Fig. 24 · Handling the camera 13

13.9.2 Procedure

Follow this procedure:

1. To turn on the laser pointer, push and hold the laser button. 2. To turn off the laser pointer, release the laser button.

is displayed on the screen when the laser pointer is on.

13.10 Using the digital zoom function

13.10.1 General

The current zoom factor is displayed in the upper left corner of the screen.

In preview/edit mode, it is possible to pan a zoomed image by touching the screen.

Page 51 of the Flir T1020 user manual — 13.11 Assigning functions to the programmable buttons
Page 51 · click to enlarge
Page 51

Handling the camera 13

13.10.2 Figure

Flir T1020 — Handling the camera 13 diagram (page 51)
Fig. 25 · Handling the camera 13

13.10.3 Procedure

Follow this procedure:

1. To zoom, push the zoom button left or right.

13.11 Assigning functions to the programmable buttons

13.11.1 General

There are four programmable buttons: two hardware buttons, and two software buttons on the screen.

Flir T1020 — 13.11 Assigning functions to the programmable buttons diagram (page 51)
Fig. 26 · 13.11 Assigning functions to the programmable button…
Flir T1020 — 13.11 Assigning functions to the programmable buttons diagram (page 51)
Fig. 27 · 13.11 Assigning functions to the programmable button…
Page 52 of the Flir T1020 user manual — 13.13 Changing lenses
Page 52 · click to enlarge
Page 52

Handling the camera 13

1. Programmable button .
2. Programmable button . 3. Programmable button P3. 4. Programmable button P4.

You can assign different functions to the programmable buttons. For a complete list of functions, see section 25.1.4 Programmable buttons, page 84.

13.11.2 Procedure

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Settings). 3. Push the joystick to display the Settings menu. 4. Select Programmable buttons and push the joystick. 5. Select one of the buttons and push the joystick:

  • P Button : Hardware button .
  • P2 Button : Hardware button .
  • P3 Button (on screen) : Software button P3 on the screen.
  • P4 Button (on screen) : Software button P4 on the screen.
6. Select one of the functions and push the joystick.

13.12 Using the camera lamp as a flash

13.12.1 General

The camera lamp can be used as a flash for the digital camera. When the flash function is activated, the camera lamp will flash when an image is saved by pushing the Save button fully down.

13.12.2 Procedure

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Settings). 3. Push the joystick to display the Settings menu. 4. Select Device settings and push the joystick. 5. Select Lamp & laser and push the joystick. 6. Select Enable lamp & laser + Use lamp as flash and push the joystick.

grammable buttons. Select

(Settings) > Programmable buttons.

13.13 Changing lenses

Page 53 of the Flir T1020 user manual — Handling the camera 13
Page 53 · click to enlarge
Page 53

Handling the camera 13

Follow this procedure:

1. Take a firm grip around the outermost part of the lens.
Flir T1020 — Handling the camera 13 diagram (page 53)
Fig. 28 · Handling the camera 13
2. Push the release button and rotate the lens 45° counter-clockwise.
Flir T1020 — Handling the camera 13 diagram (page 53)
Fig. 29 · Handling the camera 13
Page 54 of the Flir T1020 user manual — Handling the camera 13
Page 54 · click to enlarge
Page 54

Handling the camera 13

3. Carefully pull out the lens from the lens bayonet mount.
Flir T1020 — Handling the camera 13 diagram (page 54)
Fig. 30 · Handling the camera 13
4. The infrared detector is now fully exposed. Do not touch this surface. If you see dust on the detector, follow the instructions in 31.3 Infrared detector , page 217.
Flir T1020 — Handling the camera 13 diagram (page 54)
Fig. 31 · Handling the camera 13
Page 55 of the Flir T1020 user manual — Handling the camera 13
Page 55 · click to enlarge
Page 55

Handling the camera 13

5. Note the index marks on the lens bayonet mount and on the lens.
Flir T1020 — Handling the camera 13 diagram (page 55)
Fig. 32 · Handling the camera 13
6. Align the lens correctly to the bayonet mount. Carefully push the lens into position.
Flir T1020 — Handling the camera 13 diagram (page 55)
Fig. 33 · Handling the camera 13
Page 56 of the Flir T1020 user manual — 13.14.2 Attaching the close-up lens
Page 56 · click to enlarge
Page 56

Handling the camera 13

7. Rotate the lens 45° clockwise. The lens makes a click when it locks in place.
Flir T1020 — Handling the camera 13 diagram (page 56)
Fig. 34 · Handling the camera 13

13.14 Using the close-up lens

13.14.1 General

If you need to look at small objects very close up, you can attach the close-up lens to the infrared lens.

When the close-up lens is attached, the digital camera and the infrared camera do not see the same scene. This means that functions that are based on content captured by the digi- tal camera cannot be used, e.g., continuous autofocus and some image modes.

When using the close-up lens, keep the following in mind. (For instructions, see section 13.14.2 Attaching the close-up lens, page 42.)

  • For best performance, adjust the focus to infinity.
  • The working distance for the close-up lens is 97 mm. (The working distance is the distance between the front of the lens and the closest surface of the object when the object is in sharp focus.)
  • You must activate the global parameter External IR window compensation .
  • Only use the Thermal image mode.
  • Deactivate continuous autofocus.
  • Do not use the laser pointer.

13.14.2 Attaching the close-up lens

Page 57 of the Flir T1020 user manual — Handling the camera 13
Page 57 · click to enlarge
Page 57

Handling the camera 13

Follow this procedure:

1. Before attaching the close-up lens, adjust the focus to infinity by doing the following:

1.1. Aim the camera toward a distant object (more than 40 m (130′) away). 1.2. Autofocus the camera (see section 13.7 Autofocusing the infrared camera, page 34) or adjust the focus manually (see section 13.6 Adjusting the infrared camera focus manually, page 33).

2. Remove the outermost rubber protection from the infrared lens.
Flir T1020 — Handling the camera 13 diagram (page 57)
Fig. 35 · Handling the camera 13
3. Align the close-up lens with the infrared lens. Carefully push the close-up lens into position.
Flir T1020 — Handling the camera 13 diagram (page 57)
Fig. 36 · Handling the camera 13
4. Turn the close-up lens clockwise until it stops.
Flir T1020 — Handling the camera 13 diagram (page 57)
Fig. 37 · Handling the camera 13
Page 58 of the Flir T1020 user manual — 13.14.3 Removing the close-up lens
Page 58 · click to enlarge
Page 58

Handling the camera 13

5. Activate the global parameter External IR window compensation by doing the following:

5.1. Push the joystick to display the menu system.

5.2. Select

(Measurement parameters) and push the joystick. This displays a submenu.

5.3. Select

(External IR window compensation) and push the joystick. This dis- plays a dialog box.

5.4. In the dialog box, define the settings for the infrared window compensation:

  • Turn compensation on/off : Select On .
  • Temperature : Select the temperature of the close-up lens.
  • Transmission : Select 0.89, which is a typical transmission value for the close-up lens.

5.5. Push the Back button to go back in the menu system.

5.6. The status icon

is now displayed.

6. Select the image mode Thermal by doing the following:

6.1. Push the joystick to display the menu system.

6.2. Select

(Image mode) and push the joystick. This displays a submenu.

6.3. Select

(Thermal) and push the joystick.

6.4. Push the Back button to go back in the menu system.

7. Deactivate continuous autofocus by selecting

(Settings) > Device settings > Con- tinuous autofocus = Off.

13.14.3 Removing the close-up lens

Follow this procedure:

1. Turn the close-up lens counter-clockwise until it separates from the infrared lens.
Page 59 of the Flir T1020 user manual — Handling the camera 13
Page 59 · click to enlarge
Page 59

Handling the camera 13

2. Carefully pull out the close-up lens from the infrared lens.
Flir T1020 — Handling the camera 13 diagram (page 59)
Fig. 38 · Handling the camera 13
3. Note the grooves on the infrared lens and their counterparts on the inside of the rubber protection.
Flir T1020 — Handling the camera 13 diagram (page 59)
Fig. 39 · Handling the camera 13
4. Align the rubber protection with the infrared lens.
Flir T1020 — Handling the camera 13 diagram (page 59)
Fig. 40 · Handling the camera 13
Page 60 of the Flir T1020 user manual — 13.15.1 Procedure
Page 60 · click to enlarge
Page 60

Handling the camera 13

5. Push the rubber protection into position.
6. Deactivate the global parameter External IR window compensation by doing the following:

6.1. Push the joystick to display the menu system.

6.2. Select

(Measurement parameters) and push the joystick. This displays a submenu.

6.3. Select

(External IR window compensation) and push the joystick. This dis- plays a dialog box.

6.4. In the dialog box, select Turn compensation on/off = Off.

6.5. Push the Back button to go back in the menu system.

13.15 Calibrating the compass

It is recommended that the compass is calibrated every time you move the camera to a new location.

13.15.1 Procedure

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Settings). 3. Push the joystick to display the Settings menu. 4. Select Device settings and push the joystick. 5. Depending on the camera configuration, select Wireless & geolocation, Wireless, or Geolocation and push the joystick. 6. Select Compass and push the joystick. 7. If the Compass check box is unchecked, push the joystick to enable the compass. 8. Select Calibrate compass and push the joystick. Follow the on-screen instructions.

Page 61 of the Flir T1020 user manual — 14.2 Saving an image
Page 61 · click to enlarge
Page 61

Saving and working with images 14

14.1 About image files

14.1.1 General

The camera saves an image file, including all thermal and visual information. This means that you can open an image file at a later time and, for example, select another image mode, apply color alarms, and add measurement tools.

The image *.jpg file is fully radiometric and saved lossless, which enables full post-proc- essing in image analysis and reporting software from FLIR Systems. There is also a regu- lar *.jpg component (lossy) for convenient viewing in non-FLIR Systems software (e.g., Microsoft Explorer).

The camera can also be configured to save an extra visual image as a separate file. Select

(Settings) > Save options & storage > Photo as separate JPEG = On.

14.1.2 File-naming convention

The default naming convention for image files is FLIRxxxx.jpg, where xxxx is a unique counter.

It is also possible to save images with a date prefix added to the file name. However, these files may not automatically be detected by third-party applications. For more information, see section the setting File naming format in section 25.1.3 Save options & storage, page 83.

14.1.3 Image capacity

The capacity of a 4 GB memory card is theoretically 1000 images (with no annotations).

14.1.4 About UltraMax

UltraMax is an image enhancement feature that increases the image resolution and lowers the noise, making small objects easier to see and measure. An UltraMax image is twice as wide and high as an ordinary image.

When an UltraMax image is captured by the camera, several ordinary images are saved within the same file. Capturing all the images can take up to 1 second. To fully utilize Ultra- Max, the images need to be slightly different, which can be accomplished by a slight movement of the camera. You should hold the camera firmly in your hands (do not put it on a tripod), which will make these images vary just a little during the capture. Correct fo- cus, a high-contrast scene, and a non-moving target are other conditions that help to achieve a good-quality UltraMax image.

At present, only FLIR Tools/Tools+ and FLIR ResearchIR Max have the ability to process UltraMax images. Other FLIR software will treat the image as a regular image.

To configure the camera for UltraMax, select

(Settings) > Save options & storage > Im- age resolution = UltraMax.

14.2 Saving an image

14.2.1 General

You can save images to the memory card.

Page 62 of the Flir T1020 user manual — 14.4.2 Procedure
Page 62 · click to enlarge
Page 62

Saving and working with images 14

14.2.2 Procedure

Follow this procedure:

1. To save an image, push the Save button fully down.

(Settings) > Save options & storage, the following may happen:

  • A preview image is displayed before the image is saved.
  • An annotation tool or the annotation menu is displayed when the image has been saved.

14.3 Previewing an image

14.3.1 General

You can preview an image before you save it. This enables you to see if the image contains the information you want before you save it. You can also adjust and edit the image.

(Settings) > Save options & storage > Preview image before saving = On.

14.3.2 Procedure

Follow this procedure:

1. To preview an image, push the Save button fully down. This displays the preview.
2. Manual image adjustment mode is now active, and the status icon

is displayed. For image adjustment instructions, see section 15.3 Adjusting the infrared image, page 53. 3. To edit the image, push the joystick. This displays a context menu. For editing instruc- tions, see section 14.5 Editing a saved image, page 49. 4. Do one of the following:

  • To save the image, push the Save button fully down.
  • To exit preview mode without saving, push the Back button .

14.4 Opening a saved image

14.4.1 General

When you save an image, the image file is stored on the memory card. To display the im- age again, open it from the image archive.

14.4.2 Procedure

Follow this procedure:

1. Push the Image archive button . 2. Move the joystick up/down or left/right to select the image you want to view. 3. Push the joystick. This displays the image at full size.
Page 63 of the Flir T1020 user manual — 14.6 Creating a PDF report in the camera
Page 63 · click to enlarge
Page 63

Saving and working with images 14

4. Do one or more of the following:
  • To switch between an infrared image and a visual image, move the joystick up/down.
  • To view the previous/next image, move the joystick left/right.
  • To edit the image, add annotations, display information, or delete the image, push the joystick. This displays a context menu.
  • To return to the image archive overview, push the Back button .

14.5 Editing a saved image

14.5.1 General

You can edit a saved image. You can also edit an image in preview mode.

14.5.2 Procedure

Follow this procedure:

1. Open the image in the image archive.
2. Push the joystick and select

(Edit) from the menu.

3. Manual image adjustment mode is now active, and the status icon

is displayed. For image adjustment instructions, see section 15.3 Adjusting the infrared image, page 53. 4. Push the joystick. This displays a context menu.

  • Select

(Cancel) to exit edit mode.

  • Select

(Measurement parameters) to change the global parameters.

  • Select

(Image mode) to change the image mode.

  • Select

(Measurement) to add a measurement tool.

  • Select

(Color) to change the color palette or set a color alarm.

  • Select

(Save) to save and exit edit mode.

14.5.3 Related topics

  • 17.5 Changing object parameters , page 64.
  • 16 Working with image modes , page 60.
  • 17 Working with measurement tools , page 62.
  • 15.5 Changing the color palette , page 56.
  • 18 Working with color alarms and isotherms , page 71.

14.6 Creating a PDF report in the camera

14.6.1 General

You can create a PDF report and save it to the memory card. You can then transfer the PDF report to a computer, iPhone, or iPad using FLIR Tools/Tools+, and send the report to a customer.

Page 64 of the Flir T1020 user manual — 14.8.2 Procedure
Page 64 · click to enlarge
Page 64

Saving and working with images 14

14.6.2 Naming convention

The naming convention for report files is REPORTxxxx.jpg, where xxxx is a unique counter.

14.6.3 Procedure

Follow this procedure:

1. Push the Image archive button . 2. Move the joystick up/down or left/right to select an image. 3. Push the joystick to display the image. 4. Push the joystick to display a context menu.
5. Select

(Information & reports) and push the joystick. This displays information about the image. 6. Select Create report and push the joystick. The created report will be available in the archive.

14.7 Deleting an image

14.7.1 General

You can delete an image file from the memory card.

14.7.2 Procedure

Follow this procedure:

1. Push the Image archive button . 2. Move the joystick up/down or left/right to select the image you want to delete. 3. Push the joystick to display the image.
4. Push the joystick and select

(Delete) from the menu. This displays a dialog box. 5. Use the joystick to select Delete. Push the joystick to confirm.

14.8 Deleting multiple images

14.8.1 General

You can delete multiple image files from the memory card.

14.8.2 Procedure

Follow this procedure:

1. Push the Image archive button . 2. Touch and hold one of the images you want to delete. This displays a context menu.
Page 65 of the Flir T1020 user manual — 14.10.2 Procedure
Page 65 · click to enlarge
Page 65

Saving and working with images 14

3. Touch all the other images you want to delete.
Flir T1020 — Saving and working with images 14 diagram (page 65)
Fig. 41 · Saving and working with images 14
4. Use the joystick to select

(Delete) and push the joystick. This displays a dialog box. 5. Use the joystick to select Delete. Push the joystick to confirm.

14.9 Deleting all images

14.9.1 General

You can delete all image files from the memory card.

14.9.2 Procedure

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Settings). 3. Push the joystick to display the Settings menu. 4. Select Save options & storage and push the joystick. 5. Select Delete all saved files... and push the joystick. This displays a dialog box where you can choose to execute the delete action or to cancel. 6. To permanently delete all saved files, select Delete and push the joystick.

14.10 Resetting the image counter

14.10.1 General

You can reset the numbering of the image file names.

14.10.2 Procedure

Follow this procedure:

1. Push the joystick to display the menu system.
Page 66 of the Flir T1020 user manual — Saving and working with images 14
Page 66 · click to enlarge
Page 66

Saving and working with images 14

2. Use the joystick to go to

(Settings). 3. Push the joystick to display the Settings menu. 4. Select Device settings and push the joystick. 5. Select Reset options and push the joystick. 6. Select Reset image counter... and push the joystick. This displays a dialog box where you can choose to execute the reset action or to cancel. 7. To reset the counter, select Reset and push the joystick.

Page 67 of the Flir T1020 user manual — 15.3 Adjusting the infrared image
Page 67 · click to enlarge
Page 67

Achieving a good image 15

15.1 General

A good image depends on several different settings, although some settings affect the im- age more than others.

These are the settings you need to experiment with:

  • Adjusting the infrared camera focus.
  • Adjusting the infrared image, automatically or manually.
  • Selecting a suitable temperature range.
  • Selecting a suitable color palette.
  • Changing the object parameters.
  • Calibrating the camera.

The following sections explain how to change these settings.

In some situations, you may also want to hide the overlay graphics for a better view.

15.2 Adjusting the infrared camera focus

It is very important to adjust the focus correctly. Incorrect focus adjustment affects how the image modes work. It also affects the temperature measurement.

You can adjust the focus manually by rotating the focus ring. For more information, see section 13.6 Adjusting the infrared camera focus manually, page 33.

You can autofocus the infrared camera by the press of a button:

  • The camera can be configured to autofocus when you push the Save button half-way

down. To enable the autofocus function of the Save button, select

(Settings) > Save options & storage > Save button half-press = Autofocus.

  • You can assign the autofocus function to the programmable button or . For more information, see section 13.11 Assigning functions to the programmable buttons , page 37.

The infrared camera can also be set up to perform continuous autofocusing. For more in- formation, see section 13.8 Continuous autofocus, page 35.

15.3 Adjusting the infrared image

15.3.1 General

An infrared image can be adjusted automatically or manually.

In automatic mode, the camera continuously adjusts the level and span for the best image presentation. The colors are distributed based on the thermal content of the image (histo- gram color distribution). The temperature scale to the right of the screen shows the upper and lower temperatures of the current span.

In manual mode, you can adjust the temperature scale to values close to the temperature of a specific object in the image. This will make it possible to detect anomalies and smaller temperature differences in the part of the image of interest. In manual mode, the colors are distributed evenly from the lowest to the highest temperature (linear color distribution). This is indicated by lines on the temperature scale.

There are two different settings for the manual adjustment mode:

  • Level, Span : With this setting, you can manually adjust the level and span.
  • Level, Max, Min : With this setting, you can manually adjust the level. You can also change the upper and lower temperatures individually.
Page 68 of the Flir T1020 user manual — 15.3.3 Example 2
Page 68 · click to enlarge
Page 68

Achieving a good image 15

Select the type of manual image adjustment mode under

(Settings) > Device settings > User interface options > Manual adjustment mode.

When manual image adjustment mode is active, the status icon

is displayed.

  • In live mode, push the button to switch between automatic and manual image adjustment modes. You can also switch between the modes by touching the temperature scale on the screen.
  • In preview/edit mode, manual image adjustment mode is active.

image while remaining in manual image adjustment mode. Select

(Settings) > Pro- grammable buttons.

15.3.2 Example 1

Here are two infrared images of a building. In the left image, which is auto-adjusted, the large temperature span between the clear sky and the heated building makes a correct analysis difficult. You can analyze the building in more detail if you change the temperature scale to values close to the temperature of the building.

Flir T1020 — 15.3.2 Example 1 diagram (page 68)
Fig. 42 · 15.3.2 Example 1
Flir T1020 — 15.3.2 Example 1 diagram (page 68)
Fig. 43 · 15.3.2 Example 1

15.3.3 Example 2

Here are two infrared images of an isolator in a power line. To make it easier to analyze the temperature variations in the isolator, the temperature in the right image has been changed to values close to the temperature of the isolator.

Flir T1020 — 15.3.3 Example 2 diagram (page 68)
Fig. 44 · 15.3.3 Example 2
Flir T1020 — 15.3.3 Example 2 diagram (page 68)
Fig. 45 · 15.3.3 Example 2
Show 4 more labels / short text on this page
Automatic · Manual · Automatic · Manual
Page 69 of the Flir T1020 user manual — 15.4.2 Procedure
Page 69 · click to enlarge
Page 69

Achieving a good image 15

15.3.4 Manual adjustment in Level, Span mode

Follow this procedure:

1. In live mode, push the button to enter manual adjustment mode. 2. Move the joystick up/down to increase/decrease the level. 3. Move the joystick left/right to increase/decrease the span.
4. (Optional step.) In preview/edit mode, push the button to perform a one-shot autoadjust sequence.

15.3.5 Manual adjustment in Level, Max, Min mode

Follow this procedure:

1. In live mode, push the button to enter manual adjustment mode. 2. To simultaneously change the temperature scale minimum and maximum limits, move the joystick up/down. 3. To change the minimum limit or the maximum limit, do the following:
  • Move the joystick left/right to select (highlight) the maximum or minimum temperature.
  • Move the joystick up/down to change the value of the highlighted temperature.
4. (Optional step.) In preview/edit mode, push the button to perform a one-shot autoadjust sequence.

15.4 Changing the temperature range

15.4.1 General

You must change the temperature range to suit the expected temperature of the object you are inspecting.

15.4.2 Procedure

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Settings). 3. Push the joystick to display the Settings menu. 4. Select Camera temperature range and push the joystick.

Page 70 of the Flir T1020 user manual — 15.5 Changing the color palette
Page 70 · click to enlarge
Page 70

Achieving a good image 15

5. Select the appropriate temperature range and push the joystick.
Flir T1020 — Achieving a good image 15 diagram (page 70)
Fig. 46 · Achieving a good image 15

mable buttons. Select

(Settings) > Programmable buttons.

15.5 Changing the color palette

15.5.1 General

You can change the color palette that the camera uses to display different temperatures. A different palette can make it easier to analyze an image.

Flir T1020 — 15.5 Changing the color palette diagram (page 70)
Fig. 47 · 15.5 Changing the color palette
Flir T1020 — 15.5 Changing the color palette diagram (page 70)
Fig. 48 · 15.5 Changing the color palette
Flir T1020 — 15.5 Changing the color palette diagram (page 70)
Fig. 49 · 15.5 Changing the color palette
Flir T1020 — 15.5 Changing the color palette diagram (page 70)
Fig. 50 · 15.5 Changing the color palette
Show 4 more labels / short text on this page
Iron · Arctic · Rainbow · Rainbow high contrast
Page 71 of the Flir T1020 user manual — 15.6 Changing the object parameters
Page 71 · click to enlarge
Page 71

Achieving a good image 15

Flir T1020 — Achieving a good image 15 diagram (page 71)
Fig. 51 · Achieving a good image 15
Flir T1020 — Achieving a good image 15 diagram (page 71)
Fig. 52 · Achieving a good image 15
Flir T1020 — Achieving a good image 15 diagram (page 71)
Fig. 53 · Achieving a good image 15

15.5.2 Procedure

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Color). 3. Push the joystick to display a submenu. 4. Use the joystick to select a different palette. 5. Push the joystick.

15.6 Changing the object parameters

For accurate measurements, you must set the object parameters:

  • External IR window compensation .
  • Object distance .
  • Atmospheric temperature .
  • Relative humidity .
  • Reflected temperature .
  • Emissivity .

You can set the object parameters globally. You can also change the Emissivity, Reflected temperature, and Object distance parameters locally for a measurement tool.

For more information, see section 17.5 Changing object parameters, page 64.

White hot · Black hot · Lava

Page 72 of the Flir T1020 user manual — 15.8 Hiding all overlay
Page 72 · click to enlarge
Page 72

Achieving a good image 15

15.7 Calibrating the camera

15.7.1 General

Calibration of the camera is performed as a non-uniformity correction (NUC). An NUC is an image correction carried out by the camera software to compensate for different sensi- tivities of detector elements and other optical and geometrical disturbances1.

Calibration is needed whenever the output image becomes spatially noisy. The output can become spatially noisy when the ambient temperature changes (such as from day to night operation, and vice versa).

The calibration is carried out automatically when needed. It is also possible to perform a calibration manually.

While the calibration is in progress, the text Calibrating... is displayed.

15.7.2 Manual calibration

You may, for example, want to perform a manual calibration just before you start recording a video sequence.

15.7.2.1 Procedure

Follow this procedure:

1. To perform a manual calibration, push and hold down the Image archive button for more than 2 seconds.

(Settings) > Programmable buttons.

15.8 Hiding all overlay

15.8.1 General

The camera overlay consists of overlay graphics and image overlay information. The over- lay graphics include items such as measurement tool symbols, result tables, and status icons. The image overlay information, which you activate on the Settings menu, provides additional information such as the date, emissivity, and atmospheric temperature.

You can choose to hide all camera overlay by the press of a programmable button.

Flir T1020 — 15.8 Hiding all overlay diagram (page 72)
Fig. 54 · 15.8 Hiding all overlay
Flir T1020 — 15.8 Hiding all overlay diagram (page 72)
Fig. 55 · 15.8 Hiding all overlay

Image with camera overlay and image overlay information.

Image with all overlay hidden.

1. Definition from the impending international adoption of DIN 54190-3 (Non-destructive testing – Thermographic

testing – Part 3: Terms and definitions).

lect

Page 73 of the Flir T1020 user manual — Achieving a good image 15
Page 73 · click to enlarge
Page 73

Achieving a good image 15

15.8.2 Procedure

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Settings). 3. Push the joystick to display the Settings menu. 4. Select Programmable buttons and push the joystick. 5. Select one of the buttons and push the joystick. 6. Select Hide image overlay graphics and push the joystick. You have now assigned this function to the selected programmable button.

Page 74 of the Flir T1020 user manual — 16.2 Image examples
Page 74 · click to enlarge
Page 74

Working with image modes 16

16.1 General

The camera captures both thermal and visual images at the same time. By your choice of image mode, you select which type of image to display on the screen.

The camera supports the following image modes:

  • Thermal MSX (Multi Spectral Dynamic Imaging): The camera displays infrared images where the edges of the objects are enhanced with visual image details.
  • Thermal : A full infrared image is displayed.
  • Picture in picture : An infrared image frame is displayed on top of the visual image.
  • Digital camera : The visual image captured by the digital camera is displayed.

Note

  • These image modes only work correctly for calibrated lenses. The lens that ships with the camera is factory calibrated. To have a new lens calibrated, you must send in the camera and the lens to your local service department.
  • All thermal and visual information is stored when an image is saved. This means that you can edit the image later, in the image archive, in FLIR Tools/Tools+, or in FLIR ResearchIR Max, and select any of the image modes.

16.2 Image examples

This table explains the different types of image modes.

Flir T1020 — 16.2 Image examples diagram (page 74)
Fig. 56 · 16.2 Image examples
Flir T1020 — 16.2 Image examples diagram (page 74)
Fig. 57 · 16.2 Image examples

Image mode Image · Thermal · Thermal MSX

Page 75 of the Flir T1020 user manual — 16.3 Selecting the image mode
Page 75 · click to enlarge
Page 75

Working with image modes 16

Flir T1020 — Working with image modes 16 diagram (page 75)
Fig. 58 · Working with image modes 16
Flir T1020 — Working with image modes 16 diagram (page 75)
Fig. 59 · Working with image modes 16

16.3 Selecting the image mode

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Image mode). 3. Push the joystick to display a submenu. 4. Use the joystick to go to one of the image modes:

(Thermal MSX)

(Picture in picture)

(Digital camera)

5. Push the joystick confirm. 6. If Picture in picture mode is selected, you can at this point move and resize the infrared image frame using the touch screen.
Show 8 more labels / short text on this page
Image mode Image · Picture in picture · Digital camera · • · • · (Thermal) · • · •
Page 76 of the Flir T1020 user manual — 17.3.2 Procedure
Page 76 · click to enlarge
Page 76

Working with measurement tools 17

17.1 General

To measure a temperature, you can use one or more measurement tools, e.g., a spotmeter or a box.

Flir T1020 — 17.1 General diagram (page 76)
Fig. 60 · 17.1 General

17.2 Adding/removing measurement tools

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Measurement). 3. Push the joystick to display a submenu.

  • Select

(No measurements) to remove all tools.

  • Select

(Center spot) to add a center spot.

  • Select

(Hot spot) to add a hot spot detection within a box area.

  • Select

(Cold spot) to add a cold spot detection within a box area.

  • Select

(User preset 1) to add user preset 1. (Not available in all camera models.)

  • Select

(User preset 2) to add user preset 2. (Not available in all camera models.)

4. Push the joystick. This displays the measurement tool or the group of preset tools on the screen.

17.3 Working with user presets

17.3.1 General

A user preset is a measurement tool, or a group of measurement tools, with predefined characteristics.

17.3.2 Procedure

Follow this procedure:

1. Push the joystick to display the menu system.
Page 77 of the Flir T1020 user manual — 17.4.2 Procedure
Page 77 · click to enlarge
Page 77

Working with measurement tools 17

2. Use the joystick to go to

(Settings). 3. Push the joystick to display the Settings menu. 4. Select Define user presets and push the joystick. 5. Select Define preset 1 or Define preset 2 and push the joystick. This displays a context menu.

6. Select

(Add measurement). 7. Push the joystick. This displays a submenu.

  • Select

(Add spot) to add a spot.

  • Select

(Add box) to add a box.

  • Select

(Add circle) to add a circle.

  • Select

(Add line) to add a line.

  • Select

(Add delta) to set up a differential calculation.

8. Push the joystick. This displays the measurement tool on the screen. 9. Push the joystick. This displays a context menu, where you can select one or more of the following actions (depending on the type of tool):
  • Remove the tool.
  • Resize, move, center, and rotate the tool.
  • Display maximum, minimum, and average values.
  • Set alarms.
  • Set local parameters.
  • When completed, select

(Done).

10. When all measurement tools have been added, select

(Save as preset).

17.4 Resizing or moving a measurement tool

17.4.1 General

You can resize and move a measurement tool.

17.4.2 Procedure

Note

  • This procedure assumes that you have previously laid out a measurement tool or user preset on the screen.
  • You can also move and resize the measurement tool by touching the screen.
Page 78 of the Flir T1020 user manual — 17.5.2 Types of parameters
Page 78 · click to enlarge
Page 78

Working with measurement tools 17

Follow this procedure:

1. To select the measurement tool, touch the tool on the screen. The tool is now displayed with one or more handles.

Spot measurement tool:

Area measurement tool:

2. Push the joystick—or touch and hold the tool. This displays a context menu.
  • Select

(Resize) to change the size of the tool.

  • Select

(Move) to move the tool.

3. Move the joystick up/down and left/right to resize or move the tool.
4. When completed, push the joystick and select

(Done).

17.5 Changing object parameters

17.5.1 General

For accurate measurements, you must set the object parameters.

17.5.2 Types of parameters

The camera can use these object parameters:

  • External IR window compensation , i.e., the temperature of any protective windows, external lenses (e.g., the close-up lens), etc., that are set up between the camera and the object of interest. If no protective window, protective shield, or external lens is used, this value is irrelevant and should be left inactive.
  • Object distance , i.e., the distance between the camera and the object of interest.
  • Atmospheric temperature , i.e., the temperature of the air between the camera and the object of interest.
  • Relative humidity , i.e., the relative humidity of the air between the camera and the object of interest.
  • Reflected temperature , which is used when compensating for the radiation from the surroundings reflected by the object into the camera. This property of the object is called “reflectivity”.
  • Emissivity , i.e., how much radiation an object emits, compared with the radiation of a theoretical reference object at the same temperature (called a “blackbody”). The opposite of emissivity is reflectivity. The emissivity determines how much of the radiation originates from the object as opposed to being reflected by it.

by material instead of by value. Select

(Settings) > Device settings > User interface options > Emissivity mode > Select from materials table.

Of the object parameters, Emissivity is the most important parameter to set correctly. If the Emissivity is set to a low value, the Reflected temperature also becomes important. The parameters Object distance, Atmospheric temperature, and Relative humidity are relevant

Page 79 of the Flir T1020 user manual — 17.5.4 Procedure
Page 79 · click to enlarge
Page 79

Working with measurement tools 17

for longer distances. The External IR window compensation must be activated if a protec- tive window or external lens is used.

17.5.3 Recommended values

If you are unsure about the values, the following are recommended:

Object distance 1.0 m (3.3′)

Atmospheric temperature 20°C (69°F)

Reflected temperature 20°C (69°F)

Emissivity 0.95

17.5.4 Procedure

You can set the object parameters globally. You can also change the Emissivity, Reflected temperature, and Object distance parameters locally for a measurement tool.

Local parameters are normally only effective for a fixed setup, where each measurement tool is set to a specific object of interest. In a general handheld application, the global pa- rameters are usually sufficient.

17.5.4.1 Setting global parameters

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Measurement parameters). 3. Push the joystick to display a submenu. Use the joystick to select one or more of the global object parameters:

(External IR window compensation)

(Object distance)

(Atmospheric temperature)

(Relative humidity)

(Reflected temperature)

4. Push the joystick to display a dialog box. 5. Use the joystick to change the parameter. 6. Push the joystick. This closes the dialog box.

17.5.4.2 Changing local parameters

You can change the local parameters for a measurement tool.

A P next to the measurement tool on the screen indicates that local parameters are acti- vated for the tool.

Show 8 more labels / short text on this page
Relative humidity 50% · • · • · • · • · • · • · (Emissivity)
Page 80 of the Flir T1020 user manual — 17.6 Displaying values in the result table and displaying a graph
Page 80 · click to enlarge
Page 80

Working with measurement tools 17

Flir T1020 — Working with measurement tools 17 diagram (page 80)
Fig. 61 · Working with measurement tools 17

Follow this procedure:

1. To select the measurement tool, touch the tool on the screen. The tool is now displayed with one or more handles. 2. Push the joystick—or touch and hold the tool. This displays a context menu.
3. Use the joystick to go to

(Use local parameters).

4. Push the joystick.

(icon with gray indicator) is displayed.

5. Push the joystick to activate the use of local parameters.

(icon with blue indica- tor) is displayed together with a submenu. 6. Use the joystick to select an object parameter. 7. Push the joystick to display a dialog box. 8. Use the joystick to change the parameter. 9. Push the joystick. This closes the dialog box.

17.5.5 Related topics

For in-depth information about parameters, and how to correctly set the emissivity and re- flected apparent temperature, see section 35 Thermographic measurement techniques, page 229.

17.6 Displaying values in the result table and displaying a graph

17.6.1 General

For the box, circle, and line tools, you can set the camera to display the maximum, mini- mum, and average values in the result table.

For the line tool, you can also display a graph.

Flir T1020 — 17.6 Displaying values in the result table and displaying a graph diagram (page 80)
Fig. 62 · 17.6 Displaying values in the result table and displ…
Page 81 of the Flir T1020 user manual — 17.7.2 Procedure
Page 81 · click to enlarge
Page 81

Working with measurement tools 17

17.6.2 Procedure

Follow this procedure:

1. To select the measurement tool, touch the tool on the screen. The tool is now displayed with one or more handles. 2. Push the joystick—or touch and hold the tool. This displays a context menu.
3. Use the joystick to go to (depending on the tool)

(Max/Min/Avg/Alarm) or (Graph/Max/Min/Avg/Alarm). 4. Push the joystick. This displays a submenu.

  • (Option available for the line tool.) Select

(Graph) and push the joystick to dis- play a graph.

  • Select

(Max) and push the joystick to display the maximum value.

  • Select

(Min) and push the joystick to display the minimum value.

  • Select

(Avg) and push the joystick to display the average value.

  • (Optional step.) You can choose to show or hide the maximum and minimum

markers (the hot/cold spots). Select

(Max & min markers) and push the joystick to toggle:

  • When

(icon with grey indicator) is displayed, the markers are hidden.

  • When

(icon with blue indicator) is displayed, the markers are shown.

5. When completed, move the joystick down to close the submenu.
6. Select

(Done) and push the joystick.

17.7 Creating and setting up a difference calculation

17.7.1 General

A difference calculation gives the difference between the values of two known measure- ment results.

17.7.2 Procedure

Note

  • You can set up a difference calculation when defining user presets, or when editing an image in the archive.
  • This procedure assumes that you have previously laid out at least one measurement tool on the screen.

, · , or

Page 82 of the Flir T1020 user manual — 17.8.3 Alarm signals
Page 82 · click to enlarge
Page 82

Working with measurement tools 17

17.7.2.1 Procedure

Follow this procedure:

1. To set up a difference calculation, do the following:
  • If you are defining user presets, select

(Add measurement) and then select

(Add delta).

  • If you are editing an image in the archive, select

(Measurement) and then select

(Add delta).

2. Push the joystick. This displays a dialog box where you can select the measurement tools that you want to use in the difference calculation. You can also select a fixed-temperature reference.
Flir T1020 — Working with measurement tools 17 diagram (page 82)
Fig. 63 · Working with measurement tools 17
3. Push the joystick. The result of the difference calculation is now displayed on the screen.

17.8 Setting a measurement alarm

17.8.1 General

You can make the camera trigger an alarm when certain measurement conditions are met.

17.8.2 Types of alarm

You can choose between the following alarm types:

  • Above : Triggers an alarm when the temperature is above the preset alarm temperature.
  • Below : Triggers an alarm when the temperature is below the preset alarm temperature.

17.8.3 Alarm signals

When an alarm is set, the symbol

is displayed in the result table.

When an alarm is triggered, the value in the result table is displayed in red (above alarm)

or blue (below alarm) and the symbol

(below alarm) is blinking.

(above alarm) or

Page 83 of the Flir T1020 user manual — Note
Page 83 · click to enlarge
Page 83

Working with measurement tools 17

You can also set an audible alarm (there will be a “beep” when the alarm is triggered).

17.8.4 Procedure

There are different procedures for setting up an alarm for a spot, box, circle, or line and for a difference calculation.

17.8.4.1 Setting up an alarm for a spot

Follow this procedure:

1. To select the spot, touch the tool on the screen. The tool is now displayed with a frame. 2. Push the joystick—or touch and hold the tool. This displays a context menu.
3. Use the joystick to go to

(Set alarm on spot). 4. Push the joystick. This displays a dialog box where you can define the settings for the alarm.

  • Alarm condition : The condition that triggers the alarm. Applicable values are Above , Below , or Off .
  • Alarm limit : The temperature value that will be the critical condition when an alarm is triggered or not.
  • Alarm sound : Applicable values are Beep or No sound .
5. Push the joystick. This closes the dialog box.

17.8.4.2 Setting up an alarm for a box, circle, or line

Follow this procedure:

1. To select the measurement tool, touch the tool on the screen. The tool is now displayed with one or more handles. 2. Push the joystick—or touch and hold the tool. This displays a context menu.
3. Use the joystick to go to (depending on tool)

(Max/Min/Avg/Alarm) or (Graph/Max/Min/Avg/Alarm). 4. Push the joystick. This displays a submenu.

5. Select

(Set alarm). 6. Push the joystick. This displays a dialog box where you can define the settings for the alarm.

  • Alarm condition : The condition that triggers the alarm. Applicable values are Above , Below , or Off .
  • Select measurement : Applicable settings are the values you have previously defined ( Max , Min , and/or Avg ).
  • Alarm limit : The temperature value that will be the critical condition when an alarm is triggered or not.
  • Alarm sound : Applicable values are Beep or No sound .
7. Push the joystick. This closes the dialog box.

17.8.4.3 Setting up an alarm for a difference calculation

Note

  • You can set up an alarm for a difference calculation when defining user presets, or when editing an image in the archive.
  • This procedure assumes that you have previously set up a difference calculation.

, · , or

Page 84 of the Flir T1020 user manual — Working with measurement tools 17
Page 84 · click to enlarge
Page 84

Working with measurement tools 17

Follow this procedure:

1. To set up an alarm for a difference calculation, do the following:
  • If you are defining user presets, select

(Add measurement). This displays a submenu.

  • If you are editing an image in the archive, select

(Measurement). This displays a submenu.

2. Select

(Select). This displays a dialog box. 3. Select Delta. This displays a context menu.

4. Use the joystick to go to

(Set alarm on delta). 5. Push the joystick. This displays a dialog box where you can define the settings for the alarm.

  • Alarm condition : The condition that triggers the alarm. Applicable values are Above , Below , or Off .
  • Alarm limit : The temperature value that will be the critical condition when an alarm is triggered or not.
  • Alarm sound : Applicable values are Beep or No sound .
6. Push the joystick. This closes the dialog box.
Page 85 of the Flir T1020 user manual — 18.1.2 Image examples
Page 85 · click to enlarge
Page 85

Working with color alarms and isotherms 18

18.1 Color alarms

18.1.1 General

By using color alarms (isotherms), anomalies can easily be discovered in an infrared im- age. The isotherm command applies a contrasting color to all pixels with a temperature above, below, or between the set temperature levels. The camera also features isotherm types that are specific to the building trade: condensation and insulation alarms.

You can make the camera trigger the following types of color alarms:

  • Above alarm : This will apply a contrasting color to all pixels with a temperature above the specified temperature level.
  • Below alarm : This will apply a contrasting color to all pixels with a temperature below the specified temperature level.
  • Interval alarm : This will apply a contrasting color to all pixels with a temperature between two specified temperature levels.
  • Condensation alarm : Triggers when the camera detects a surface where the relative humidity exceeds a preset value.
  • Insulation alarm : Triggers when there is an insulation deficiency in a wall.

18.1.2 Image examples

This table explains the different color alarms (isotherms).

Flir T1020 — 18.1.2 Image examples diagram (page 85)
Fig. 64 · 18.1.2 Image examples
Flir T1020 — 18.1.2 Image examples diagram (page 85)
Fig. 65 · 18.1.2 Image examples

Color alarm Image · Above alarm · Below alarm

Page 86 of the Flir T1020 user manual — 18.2 Setting up above, below, and interval alarms
Page 86 · click to enlarge
Page 86

Working with color alarms and isotherms 18

Flir T1020 — Working with color alarms and isotherms 18 diagram (page 86)
Fig. 66 · Working with color alarms and isotherms 18
Flir T1020 — Working with color alarms and isotherms 18 diagram (page 86)
Fig. 67 · Working with color alarms and isotherms 18
Flir T1020 — Working with color alarms and isotherms 18 diagram (page 86)
Fig. 68 · Working with color alarms and isotherms 18

18.2 Setting up above, below, and interval alarms

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Color). 3. Push the joystick to display a submenu. Use the joystick to select the type of alarm:

(Above alarm)

(Below alarm)

(Interval alarm)

4. Push the joystick. The threshold temperature is displayed at the top of the screen.
Show 7 more labels / short text on this page
Color alarm Image · Interval alarm · Condensation alarm · Insulation alarm · • · • · •
Page 87 of the Flir T1020 user manual — 18.3.3 Setting up condensation and insulation alarms
Page 87 · click to enlarge
Page 87

Working with color alarms and isotherms 18

5. To change the threshold temperature, do the following:
  • For the Interval alarm , move the joystick left/right to select the low/high-temperature value.
  • Move the joystick up/down to change the threshold temperature.

18.3 Building isotherms

18.3.1 About the Condensation alarm

To detect areas with potential moisture problems, you can use the Condensation alarm. You can set the relative humidity above which the isotherm will colorize the image.

18.3.2 About the Insulation alarm

The Insulation alarm can detect areas where there may be an insulation deficiency in the building. It will trigger when the insulation level (which is called the thermal index in the camera) falls below a preset value of the energy leakage through a wall.

Different building codes recommend different values for the insulation level, but typical val- ues are 60–80% for new buildings. Refer to your national building code for recommendations.

18.3.3 Setting up condensation and insulation alarms

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Color). 3. Push the joystick to display a submenu. Use the joystick to select the type of alarm:

(Condensation alarm)

(Insulation alarm)

4. Push the joystick. This displays a dialog box where you can define the settings for the alarm.

For the Condensation alarm, the following parameters can be set:

  • Atmospheric temperature : The current atmospheric temperature.
  • Relative humidity : The current relative humidity.
  • Relative humidity limit : The relative humidity level at which you want the alarm to be triggered. A relative humidity of 100% means that water vapor condenses from the air as liquid water (= dewpoint). A relative humidity of about 70% or above can cause mold.

For the Insulation alarm, the following parameters can be set:

  • Indoor temperature : The current indoor temperature.
  • Outdoor temperature : The current outdoor temperature.
  • Thermal index : The insulation level, an integer between 0 and 100.
5. Push the joystick. This closes the dialog box.

• · •

Page 88 of the Flir T1020 user manual — 19.3 Adding a table
Page 88 · click to enlarge
Page 88

Annotating images 19

19.1 General

You can save additional information with an infrared image by using annotations. Annota- tions make reporting and post-processing more efficient, by providing essential informa- tion about the image, e.g., conditions and information about where an image is taken.

Annotations are added to the image file, and can be viewed and edited in the image ar- chive, and also when moving files from the camera to reporting software on the computer.

  • You can set the camera to display annotation tools before an image is saved. Select

(Settings) > Save options & storage > Add annotation after saving.

  • You can also add annotations to a saved image in the image archive.

19.2 Adding a note

19.2.1 General

You can add a text note to the image file. Using this feature, you can annotate images by entering free-form text.

Flir T1020 — 19.2 Adding a note diagram (page 88)
Fig. 69 · 19.2 Adding a note

19.2.2 Procedure

Follow this procedure:

1. Open the image in the image archive. 2. Push the joystick. This displays a context menu.
3. Select

(Add note). 4. Push the joystick. This displays a soft keyboard where you can enter the text you want to save by touching the screen.

5. When completed, touch Done on the soft keyboard.

19.3 Adding a table

19.3.1 General

You can save a table with textual information to the image file. This feature is a very effi- cient way of recording information when you are inspecting a large number of similar

Page 89 of the Flir T1020 user manual — 19.4 Adding a voice annotation
Page 89 · click to enlarge
Page 89

Annotating images 19

objects. The idea behind using a table with textual information is to avoid filling out forms or inspection protocols manually.

The camera has a number of default table templates. You can also import your own table templates from FLIR Tools/Tools+—refer to the FLIR Tools/Tools+ user’s manual. The tem- plates are stored on the memory card.

Flir T1020 — Annotating images 19 diagram (page 89)
Fig. 70 · Annotating images 19

19.3.2 Procedure

Follow this procedure:

1. Open the image in the image archive. 2. Push the joystick. This displays a context menu.
3. Select

(Add table) and push the joystick.

4. Select

(Add table contents) and push the joystick. This displays the default table template that ships with the camera.

(Select default template).

5. For each row in the table, do the following:
  • Push the joystick. This displays the predefined values.
  • Move the joystick up/down to select a predefined value. Push the joystick to confirm.
  • Instead of selecting a predefined value, you can select the keyboard

and enter other text by touching the screen.

6. When completed, select Save & Exit at the bottom of the table. Push the joystick to confirm.

19.4 Adding a voice annotation

19.4.1 General

A voice annotation is an audio recording that is saved to the infrared image file. The re- cording can be played back in the camera, and in image analysis and reporting software from FLIR Systems.

The voice annotation is recorded using a Bluetooth headset. For information on how to pair a headset with the camera, see section 23 Pairing Bluetooth devices, page 81.

Page 90 of the Flir T1020 user manual — 19.5.2 Procedure
Page 90 · click to enlarge
Page 90

Annotating images 19

Flir T1020 — Annotating images 19 diagram (page 90)
Fig. 71 · Annotating images 19

19.4.2 Procedure

Follow this procedure:

1. Open the image in the image archive. 2. Push the joystick. This displays a context menu.
3. Select

(Add voice annotation) and push the joystick.

4. To start a recording, select

(Record) and push the joystick.

5. To stop the recording, select

(Stop) and push the joystick.

6. To listen to the recording, select

(Play) and push the joystick.

7. To delete the recording, select

(Delete) and push the joystick.

8. When completed, select

(Done) and push the joystick.

19.5 Adding a sketch

19.5.1 General

You can add a freehand drawing to an image.

Flir T1020 — 19.5 Adding a sketch diagram (page 90)
Fig. 72 · 19.5 Adding a sketch

19.5.2 Procedure

Follow this procedure:

1. Open the image in the image archive. 2. Push the joystick. This displays a context menu.
3. Select

(Add sketch) and push the joystick. 4. You are now in sketch mode. Draw the sketch by touching the screen.

Page 91 of the Flir T1020 user manual — Annotating images 19
Page 91 · click to enlarge
Page 91

Annotating images 19

5. Push the joystick. This displays a context menu. Do one or more of the following:
  • To change the color of the sketch tools, select

(Draw) and push the joystick. Se- lect the color and push the joystick.

  • To erase, select

(Eraser) and push the joystick. Erase parts of the sketch by touching the screen.

  • To add an arrow, circle, or cross, select

(Stamp sketch) and push the joystick. Select the type of stamp and push the joystick. The stamp is displayed in the center of the screen. You can move the stamp by using the joystick or by touching the screen.

  • To clear, select

(Clear all) and push the joystick.

  • When the sketch is completed, select

(Save) and push the joystick.

Page 92 of the Flir T1020 user manual — 20.2 Procedure
Page 92 · click to enlarge
Page 92

Programming the camera (time lapse) 20

20.1 General

You can program the camera to save images periodically (time lapse).

Flir T1020 — 20.1 General diagram (page 92)
Fig. 73 · 20.1 General

20.2 Procedure

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Recording mode). 3. Push the joystick. This displays a submenu.

4. Select

(Time lapse). 5. Push the joystick. This displays a dialog box, where you can set the save conditions:

  • Save interval : Use the joystick to set the time interval between each saved image.
  • Total number of images : Periodic saving will stop when the set number of images have been saved.
6. Push the joystick. This closes the dialog box. The time interval is displayed at the top of the screen. 7. To manually start or stop periodic saving, briefly push and release the Save button.
Page 93 of the Flir T1020 user manual — 21.2 Procedure
Page 93 · click to enlarge
Page 93

Recording video clips 21

21.1 General

You can record and save video clips to the memory card.

Flir T1020 — 21.1 General diagram (page 93)
Fig. 74 · 21.1 General

(Settings) > Save options & storage > Video compression.

  • Mpeg (*.mpg) : Mpeg recordings cannot be edited after the file has been saved.
  • Radiometric storage (*csq) : A *.csq file supports full radiometry but is only supported by FLIR Systems software. The file does not include any visual image information. With this setting, only Thermal image mode is supported when recording video. If any other image mode is active when Video recording mode is selected, the camera will autoswitch to Thermal image mode.

21.2 Procedure

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Recording mode). 3. Push the joystick. This displays a submenu.

4. Select

(Video) and push the joystick. 5. Do the following:

  • To start a recording, push and release the Save button. A counter at the top of the screen displays the duration of the recording.
  • To stop a recording, push and release the Save button.
6. The recording is automatically saved to the image archive, where you can play or delete it.
Page 94 of the Flir T1020 user manual — Note
Page 94 · click to enlarge
Page 94

Screening alarm 22

22.1 General

The screening alarm can be used, for example, at airports to detect passengers with ele- vated body temperatures, which may indicate the presence of a fever.

The screening alarm can also be used to detect temperature anomalies in a series of in- spected objects in a similar/fixed setup.

Activating the screening alarm will turn on a measurement box and screening data in the result table.

The sampled average temperature.

The alarm temperature.

The measured temperature.

The alarm will trigger when the measurement box measures a temperature higher than the alarm temperature. The alarm temperature is, in turn, the sum of a specified allowed devia- tion and a sampled average value.

22.2 Procedure

Follow this procedure:

1. Enable the screening mode by selecting

(Settings) > Device settings > User inter- face options > Screening mode = On. 2. Push the joystick to display the menu system.

3. Use the joystick to go to

(Recording mode). 4. Push the joystick. This displays a submenu.

5. Select

(Screening). 6. Push the joystick. This displays a dialog box where you can define the settings for the alarm.

  • Allowed deviation : The allowed deviation from the sampled average.
  • Alarm sound : Applicable values are Beep or No sound .
7. Push the joystick. This closes the dialog box. 8. Aim the camera toward a point of interest. The object should be within the frame of the measurement box.
9. Push and hold the programmable button to reset the sampled average.
10. Push the programmable button to sample. 11. Aim the camera toward more points of interest. Sample 10 times to build up a sample

base by pushing the programmable button .

The alarm is now set up and ready to use. Occasionally record a few samples if the alarm is used for a long time or if the conditions change.

Note

  • The algorithm has a memory of the last 10 samples. It discriminates between the highest and lowest values, and calculates an average of the remaining values.
  • Do not modify the measurement setup or activate another alarm because this will deactivate the screening alarm.
Page 95 of the Flir T1020 user manual — Note
Page 95 · click to enlarge
Page 95

Pairing Bluetooth devices 23

23.1 General

Before you can use a Bluetooth device with the camera, you need to pair the devices.

23.2 Procedure

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Settings).

3. Push the joystick to display the Settings menu. 4. Select Device settings and push the joystick. 5. Depending on the camera configuration, select Wireless & geolocation , Wireless , or Geolocation and push the joystick. 6. Select Bluetooth and push the joystick. 7. If the Bluetooth check box is unchecked, push the joystick to activate Bluetooth.
8. Select Available devices and push the joystick. 9. Wait until a list of available devices is displayed. This will take about 15 seconds. 10. When a Bluetooth device is found, select the device to add it, and begin the pairing procedure. The device is then ready to be used.

Note

  • Only Bluetooth-enabled headsets will appear in the list of available devices.
  • You can add several devices.
  • You can remove a device by selecting the device and then selecting Unpair device .
  • After adding a Bluetooth-enabled headset, it is ready to be used for adding voice annotations.
Page 96 of the Flir T1020 user manual — 24.3 Connecting the camera to a WLAN (less common use)
Page 96 · click to enlarge
Page 96

Configuring Wi-Fi 24

24.1 General

Depending on your camera configuration, you can connect the camera to a wireless local area network (WLAN) using Wi-Fi, or let the camera provide Wi-Fi access to other devices.

You can connect the camera in two different ways:

  • Most common use : Setting up the camera as a wireless access point. This method is primarily used with other devices, e.g., an iPhone or iPad.
  • Less common use : Connecting the camera to a wireless local area network (WLAN).

24.2 Setting up a wireless access point (most common use)

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Settings).

3. Push the joystick to display the Settings menu. 4. Select Device settings and push the joystick. 5. Depending on the camera configuration, select Wireless & geolocation , Wireless , or Geolocation and push the joystick. 6. Select Wi-Fi and push the joystick. 7. Select Share and push the joystick. 8. (Optional step.) To display and change the parameters, select Share settings and push the joystick.
  • To change the SSID, select Network name (SSID) and push the joystick.
  • To change the WPA2 password, select Password and push the joystick.

24.3 Connecting the camera to a WLAN (less common use)

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Settings).

3. Push the joystick to display the Settings menu. 4. Select Device settings and push the joystick. 5. Depending on the camera configuration, select Wireless & geolocation, Wireless, or Geolocation and push the joystick. 6. Select Wi-Fi and push the joystick. 7. Select Connect to network and push the joystick. 8. To display a list of the available networks, select Networks and push the joystick. 9. Select one of the available networks. Password-protected networks are indicated with a padlock icon, and for these you will need to enter a password the first time you connect to the network. After that the cam- era will connect automatically to the network. To disable the automatic connection, se- lect Forget network.

Page 97 of the Flir T1020 user manual — 25.1.3 Save options & storage
Page 97 · click to enlarge
Page 97

Changing settings 25

25.1 General

You can change a variety of settings in the camera. You do this on the Settings menu.

The Settings menu includes the following:

  • Define user presets .
  • Camera temperature range .
  • Save options & storage .
  • Programmable buttons .
  • Device settings .
Flir T1020 — 25.1 General diagram (page 97)
Fig. 75 · 25.1 General

25.1.1 Define user presets

A user preset is a measurement tool, or a group of measurement tools, with predefined characteristics. For more information, see section 17.3 Working with user presets, page 62.

  • Define preset 1 : This setting defines user preset 1.
  • Define preset 2 : This setting defines user preset 2.

25.1.2 Camera temperature range

For accurate temperature measurements, you must change the Camera temperature range setting to suit the expected temperature of the object you are inspecting.

Available temperature range options are dependent on the camera model. The unit (℃or ℉) depends on the temperature unit setting, see section 25.1.5 Device settings, page 85.

25.1.3 Save options & storage

  • Save button half-press : This setting defines the function of the Save button. Available options are:
  • Autofocus : Pushing the Save button half-way down will autofocus the infrared camera.
  • None : Pushing the Save button half-way down will have no effect. With this setting, you may want to assign the autofocus function to one of the programmable buttons.
  • Preview image before saving : This setting defines if a preview image will be displayed before the image is saved.
  • Add annotation after saving : This setting defines if an annotation tool will be displayed when the image has been saved. Available options are:
  • Save : No annotation tool will be displayed.
  • Save & add note : The note annotation tool will be displayed.
Page 98 of the Flir T1020 user manual — 25.1.4 Programmable buttons
Page 98 · click to enlarge
Page 98

Changing settings 25

  • Save & add table : The table annotation tool will be displayed. This setting also allows you to define the type of table. Available options are the default table templates. You can also create your own table in FLIR Tools/Tools+ and upload it to the camera.
  • Save & add voice annotation : The voice annotation tool will be displayed.
  • Save & add sketch : The sketch annotation tool will be displayed.
  • Save & add any annotation : The annotation tool menu will be displayed.
  • Image resolution : This setting defines the resolution of the images captured by the camera. Available options are Normal and Ultramax . For more information, see section 14.1.4 About UltraMax , page 47.
  • Video compression : This setting defines the storage format for video clips. Available options are:
  • Mpeg (*.mpeg) : MPEG recordings cannot be edited after the file has been saved.
  • Radiometric storage (*.csq) : A CSQ file supports full radiometry but is only supported by FLIR Systems software. The file does not include any visual image information. With this setting, only Thermal image mode is supported when recording video.
  • Photo as separate JPEG : A visual image is always saved in the same JPEG file as the thermal image. Enabling this setting saves an extra visual image as a separate JPEG file.
  • File naming format : This setting defines the naming format for new image/video files. The setting has no impact on already saved files in the archive. Available options are:
  • DCF : DCF (Design rule for Camera File system) is a standard that specifies the naming method of image files (and much more). With this setting, the name of a saved image/video file will be FLIRxxxx, where xxxx is a unique counter. Example: FLIR0001.
  • Date prefix : A prefix will be added to the file name, including the date and the text “IR_” for images and “MOV_” for videos. Examples: IR_2015-04-22_0002 and MOV_2015-04-22_0003. The date format will follow the Date & time format setting, see section 25.1.5 Device settings , page 85.
  • Delete all saved files... : This displays a dialog box where you can choose to permanently delete all the saved files (images, videos, and reports) from the memory card or to cancel the delete action.

25.1.4 Programmable buttons

There are four programmable buttons. For more information, see section 13.11 Assigning functions to the programmable buttons, page 37.

  • P Button : This setting assigns a function to the hardware button .
  • P2 Button : This setting assigns a function to the hardware button .
  • P3 Button (on screen) : This setting assigns a function to the software button P3 on the screen.
  • P4 Button (on screen) : This setting assigns a function to the software button P4 on the screen.

Available options for all programmable buttons:

  • No action : This is the default setting. Nothing will happen when you push/press the button.
Page 99 of the Flir T1020 user manual — 25.1.5 Device settings
Page 99 · click to enlarge
Page 99

Changing settings 25

  • Hide image overlay graphics : Hide all overlay graphics and image overlay information. For more information, see section 15.8 Hiding all overlay , page 58.
  • Calibrate : Perform a manual calibration of the camera. For more information, see section 15.7 Calibrating the camera , page 58.
  • Auto-adjust the manual temperature scale : Perform an automatic adjustment of the image while remaining in manual image adjustment mode.
  • Switch Thermal <> Digital camera : Switch between the image modes Thermal and Digital camera . For more information, see section 16 Working with image modes , page 60.
  • Switch Thermal <> Thermal MSX : Switch between the image modes Thermal and Thermal MSX . For more information, see section 16 Working with image modes , page 60.
  • Switch 1x zoom <> Max zoom : Switch between the digital zoom factor of 1× and maximum zoom.
  • Switch camera flash On <> Off : Switch between the activated/deactivated camera flash function. For more information, see section 13.12 Using the camera lamp as a flash , page 38.
  • Switch single shot <> Video : Switch between the recording modes Single shot and Video .
  • Switch between two latest palettes : Switch between the two last-used color palettes. For more information, see section 15.5 Changing the color palette , page 56.
  • Switch temperature range : Cycle through the camera temperature ranges. For more information, see section 25.1.2 Camera temperature range , page 83.

Additional options for the hardware buttons and :

  • Autofocus .
  • Continuous autofocus .
  • Switch screen rotation On <> Off .
  • Save .
  • Save + Prompt for note .
  • Save + Prompt for table .
  • Save + Prompt for voice annotation .
  • Save + Prompt for sketch .
  • Save + Select annotation from menu .
  • Preview .
  • Preview + Prompt for note .
  • Preview + Prompt for table .
  • Preview + Prompt for voice annotation .
  • Preview + Prompt for sketch .
  • Preview + Select annotation from menu .

25.1.5 Device settings

  • Language, time & units : This submenu includes settings for a number of regional parameters:
  • Language .
  • Temperature unit .
  • Distance unit .
  • Time zone
  • Date & time .
  • Date & time format .
  • Continuous autofocus : This setting is used to enable/disable continuous autofocus.
  • Display settings : This submenu includes the following settings:
Page 100 of the Flir T1020 user manual — Changing settings 25
Page 100 · click to enlarge
Page 100

Changing settings 25

  • Screen rotation : This setting defines if the orientation of the overlay graphics will change according to how you hold the camera.
  • Image overlay information : This setting specifies what image information the camera will display as an overlay on the image. For more information, see section 11.4 Image overlay information , page 29. You can select to display the following information:

– Compass. – Date & time. – Emissivity. – Reflected temperature. – Distance. – Relative humidity. – Atmospheric temperature.

  • Screen brightness : This setting defines the brightness of the screen. Available options are Low , Medium , High , and Auto .
  • Viewfinder brightness : This setting defines the brightness of the viewfinder. Available options are Low , Medium , and High .
  • HDMI : (Applicable when an HDMI cable is connected to the camera.) This setting defines the resolution of the digital video output. The setting can be used to select display of the image only, or display of the image and the entire overlay graphics.
  • Wireless & geolocation , Wireless , or Geolocation (depending on the camera configuration): This submenu includes the following settings:
  • Wi-Fi : This setting defines Wi-Fi networks. For more information, see section 24 Configuring Wi-Fi , page 82.
  • Bluetooth : This setting defines Bluetooth connectivity. For more information, see section 23 Pairing Bluetooth devices , page 81.
  • GPS : This setting is used to enable/disable the GPS.
  • Compass : This setting is used to enable/disable the compass and to calibrate the compass. For more information, see section 13.15 Calibrating the compass , page 46.
  • Lamp & laser : This submenu includes the following settings:
  • Enable lamp & laser : This setting is used to enable the camera lamp and the laser pointer.
  • Enable lamp & laser + Use lamp as flash : This setting is used to activate the flash function. When the flash function is activated, the camera lamp will flash when an image is saved.
  • Disable all : This setting is used to disable the camera lamp, laser pointer, and flash function.
  • Auto power off : This setting defines how soon the camera is automatically turned off. Available choices are Off , 5 min , and 20 min .
  • User interface options : This submenu includes the following settings:
  • Manual adjustment mode : This setting specifies the type of manual image adjustment mode. Available options are Level, Max, Min and Level, Span . For more information, see section 15.3 Adjusting the infrared image , page 53.
  • Emissivity mode : This setting specifies how the object parameter emissivity will be entered. Available options are Select values and Select from materials table . For more information, see section 17.5 Changing object parameters , page 64.
  • Screening mode : This setting is used to enable/disable screening mode. For more information, see section 22 Screening alarm , page 80.
Page 101 of the Flir T1020 user manual — 25.2 Procedure
Page 101 · click to enlarge
Page 101

Changing settings 25

  • Reset options : This setting defines a number or reset options:
  • Reset default camera mode... : This will affect the color palettes and measurement tools. Saved images will not be affected.
  • Reset device settings to factory default... : This will affect all camera settings, including regional settings. Saved images will not be affected. The camera will be restarted.
  • Reset image counter... : This will reset the numbering of the image file names. To prevent image files being overwritten, the new counter value will be based on the highest existing file name number in the image archive.
  • Camera information : This dialog displays information about the camera. No changes can be made.
  • Model .
  • Serial number .
  • Part number .
  • Software version .
  • Storage : The used and free space on the memory card.
  • Lens : The field of view of the lens.
  • Battery : The remaining battery capacity, in percent.
  • Licenses : Open source license information.

25.2 Procedure

Follow this procedure:

1. Push the joystick to display the menu system.
2. Use the joystick to go to

(Settings). 3. Push the joystick to display the Settings menu. 4. Use the joystick to select the setting you want to change.

5. To exit the Settings menu or a submenu, push the Back button .
Page 102 of the Flir T1020 user manual — 26.3 Note about authoritative versions
Page 102 · click to enlarge
Page 102

26.1 Online field-of-view calculator

Please visit http://support.flir.com and click the photo of the camera series for field-of-view tables for all lens–camera combinations.

26.2 Note about technical data

FLIR Systems reserves the right to change specifications at any time without prior notice. Please check http://support.flir.com for latest changes.

26.3 Note about authoritative versions

The authoritative version of this publication is English. In the event of divergences due to translation errors, the English text has precedence.

Any late changes are first implemented in English.

Page 103 of the Flir T1020 user manual — 26.4 FLIR T1020 12°
Page 103 · click to enlarge
Page 103

26.4 FLIR T1020 12°

P/N72501-0101 Rev.: 36730

The FLIR T1020 is designed for the expert requiring the highest performance and the latest technology available. The camera combines excellent ergonomics and feature-rich flexibility with superior image quality at an infrared resolution of 1024 × 768 pixels.

Benefits:

  • Flexible and feature rich: A wide variety of measuring and analysis functions make the FLIR T1020 flexible for your every need. Two programmable buttons provide easy access to favorite functions.
  • Highest performance with the latest technology: The FLIR T1020 is equipped with the innovative Multi Spectral Dynamic Imaging (MSX) feature, which produces an image richer in detail than ever before. With its continuous autofocus, the FLIR T1020 is a fully automatic infrared camera.
  • Support for UltraMax: When enabling UltraMax in the camera, the resolution of images can be substantially enhanced when importing the images into FLIR Tools.

Imaging and optical data

IR resolution 1024 × 768 pixels

MSX resolution 1024 × 768 pixels

Thermal sensitivity/NETD

Field of view (FOV) 12° × 9°

Minimum IR focus distance 1.3 m (4.26 ft.)

Minimum IR–visual alignment distance 1.3 m (4.26 ft.)

Focal length 83.4 mm (3.28 in.)

Spatial resolution (IFOV) 0.20 mrad

F-number 1.2

Image frequency 30 Hz

Focus One shot or manual

Digital zoom 1–8× continuous

Digital image enhancement Adaptive digital noise reduction

Detector type Focal plane array (FPA), uncooled microbolometer

Spectral range 7.5–14 µm

Detector pitch 17 µm

Display Built-in touch screen, 4.3 in. wide screen LCD, 800 × 480 pixels

Display type Capacitive touch screen

Auto orientation Automatic landscape or portrait

Viewfinder Built-in 800 × 480 pixels

Automatic image adjustment Continuous, histogram based

Show 5 more labels / short text on this page
General description · UltraMax Yes · Lens identification Automatic · Detector data · Image presentation
Page 104 of the Flir T1020 user manual — NOTE
Page 104 · click to enlarge
Page 104

Automatic image adjustment, type Standard or histogram based on the image content

Manual image adjustment Linear based, possible to adjust level/span/max./ min.

Image modes Thermal, thermal MSX, picture in picture, digital camera

Infrared image Full color infrared image

Visual image Full color visual image

Multi Spectral Dynamic Imaging (MSX) Thermal image with enhanced detail presentation

Picture in Picture Resizable and movable infrared area on the visual image

  • Gallery
  • Review thumbnail/full image on the camera
  • Edit measurements/palettes/image modes on the camera
  • Object temperature range
  • –40 to +150°C (–40 to +302°F)
  • 0 to +650°C (+32 to +1202°F)
  • +300 to +2000°C (+572 to +3632°F)
  • Accuracy
  • ±1°C (±1.8°F) or ±1% @ 25°C (77°F) for temperatures between 5 and 150°C (41 and 302° F), in range –40 to 150°C (–40 to 302°F)
  • ±2°C (±3.6°F) or ±2% of reading @ 25°C (77° F) for temperatures between –40 and 2000°C (–40 and 3632°F)

NOTE

For HSI use, above 30 Hz frame rate, the typical accuracy will be ±2.5°C (±4.5°F), or 2.5% of reading @ 25°C (77°F).

Area 5 + 5 areas (boxes and circles) with max./min./ average

Profile 1 line profile with max./min. temperature

Automatic hot/cold detection Auto hot or cold spotmeter markers within the area and profile

Measurement presets No measurements, Center spot, Hot spot, Cold spot, User preset 1, User preset 2

User presets The user can select and combine measurements from any number of spots/boxes/circles/profiles/ delta

Difference temperature Delta temperature between the measurement func- tions and the reference temperature

Reference temperature Manually set using the difference temperature

Atmospheric transmission correction Automatic, based on the inputs for distance, at- mospheric temperature, and relative humidity

Optics transmission correction Automatic, based on signals from internal sensors

Show 5 more labels / short text on this page
Image presentation · Image presentation modes · Measurement · Measurement analysis · Spotmeter 10
Page 105 of the Flir T1020 user manual — 26.4 FLIR T1020 12°
Page 105 · click to enlarge
Page 105

Emissivity correction Variable from 0.01 to 1.0 or selected from the ma- terials list

Reflected apparent temperature correction Automatic, based on the input of the reflected temperature

External optics/windows correction Automatic, based on the inputs of the window transmission and temperature

Measurement corrections Emissivity, reflected temperature, relative humidity, atmospheric temperature, object distance, external infrared window compensation

Colors (palettes) Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava

Color Alarm (isotherm) Above/below/interval

Measurement function alarm Audible/visual alarms (above/below) on any se- lected measurement function

Set-up commands Define user presets, Save options, Programmable button, Reset options, Set up camera, Wi-Fi, GPS & compass, Bluetooth, Language, Time & units, Camera information

Languages Arabic, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japa- nese, Korean, Norwegian, Polish, Portuguese, Russian, simplified Chinese, Swedish, traditional Chinese, Turkish

Camera software update Use PC software FLIR Tools

Image storage Standard JPEG, including digital image and meas- urement data, on a memory card

Storage media Removable media SD or SDHC card. Class 10 or better recommended

  • Image storage mode
  • Simultaneous storage of thermal and digital images in the same JPEG file
  • Option to store a digital photo as a separate JPEG file

Time lapse 15 seconds to 24 hours

  • File formats
  • Standard JPEG, measurement data included
  • CSQ, measurement data included

File formats, visual Standard JPEG, automatically associated with the corresponding thermal image

Voice 60 seconds (via Bluetooth) stored with the image

Text Add table, select between predefined templates

Show 6 more labels / short text on this page
Measurement analysis · Alarm · Set-up · Service functions · Storage of images · Image annotations
Page 106 of the Flir T1020 user manual — 26.4 FLIR T1020 12°
Page 106 · click to enlarge
Page 106

Image description Add short note (stored in the JPEG exif tag)

  • Sketch
  • Draw on the thermal/digital image or add predefined stamps
  • Separate PC software with extensive report generation

GPS Location data automatically added to every image from the built-in GPS

Compass Camera direction automatically added to every image

Video recording in camera

Radiometric IR-video recording Real-time radiometric recording (RTRR) to the memory card

Non-radiometric IR-video recording H.264 to the memory card

Visual video recording H.264 to the memory card

Radiometric IR-video streaming Real-time radiometric streaming (RTRS) via USB

  • Non-radiometric IR-video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Visual video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB

Digital camera Field of view adapts to the infrared lens

Video lamp Built-in LED light

Laser Activated by a dedicated button

Laser alignment Position is automatically displayed on the infrared image

Laser classification Class 2

Laser type Semiconductor AlGaInP diode laser, 1 mW, 635 nm (red)

Interfaces USB Micro-B, Bluetooth, Wi-Fi, HDMI

Bluetooth Communication with a headset

Wi-Fi Infrastructure (network) or AP

SD Card One card slot for removable SD memory cards

Audio Microphone headset via Bluetooth for the voice an- notation of images

Show 6 more labels / short text on this page
Image annotations · Geographic Information System · Video streaming · Digital camera · Laser pointer · Data communication interfaces
Page 107 of the Flir T1020 user manual — USB
Page 107 · click to enlarge
Page 107

USB

USB USB Micro-Bdata transfer to and from a PC, uncompressed colorized video
  • USB, standard
  • USB 2.0 High Speed
  • USB Micro-B connector
  • Video out
  • HDMI 640 × 480
  • HDMI 1280 × 720
  • DVI 640 × 480
  • DVI 800 × 600

Video, connector type HDMI type C

  • Wi-Fi
  • Standard: 802.11 b/g/n
  • Frequency range: 2412–2462 MHz
  • Max. output power: 15 dBm
Bluetooth Frequency range2402–2480 MHz, supports 2.1, 4.0, and 4.0 BLE

Battery type Rechargeable Li ion battery

Battery operating time >2.5 hours at 25°C (+68°F) and typical use

Charging system In camera (AC adapter or 12 V from a vehicle) or two-bay charger

Charging time 2.5 hours to 90% capacity, charging status indi- cated by LEDs

Charging temperature 0–45°C (32–113°F)

External power operation AC adapter 90–260 V AC, 50/60 Hz or 12 V from a vehicle (cable with a standard plug, optional)

Power management Automatic power-off functionality, user configura- ble between 5 minutes, 20 minutes, and no auto- matic shutdown

Operating temperature range –15°C to +50°C (+5°F to +122°F)

Storage temperature range –40 to +70°C (–40 to +158°F)

Humidity (operating and storage) IEC 60068-2-30 / 24 hours, 95% relative humidity, 25–40°C (77–104°F) / 2 cycles

  • EMC
  • ETSI EN 301 489-1 (radio)
  • ETSI EN 301 489-17
  • EN 61000-6-2 (Immunity)
  • EN 61000-6-3 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
  • ICES-003
  • Radio spectrum
  • ETSI EN 300 328
  • FCC Part 15.247
  • RSS-247 issue 1

Encapsulation IP 54 (IEC 60529)

Shock 25 g (IEC 60068-2-29)

Show 5 more labels / short text on this page
Video · Radio · Antenna Internal · Power system · Environmental data
Page 108 of the Flir T1020 user manual — Supplies & accessories:
Page 108 · click to enlarge
Page 108

Vibration 2 g (IEC 60068-2-6)

Ergonomics The viewfinder plus the 120° rotating optical block allow you to point the camera in multiple directions while maintaining a comfortable position

Weight 2.1 kg (4.6 lb.)

Camera size, excl. lens (L × W × H) 167.2 mm × 204.5 mm × 188.3 mm (6.6 in. × 8.0 in. × 7.4 in.)

Tripod mounting UNC ¼"-20

  • Warranty
  • 2 years parts and labor coverage on the camera
  • 5 years coverage on the battery
  • 10 years coverage on the detector – the most vital part of the whole camera
  • List of contents
  • Infrared camera with lens
  • Battery (2 ea.)
  • Battery charger
  • Bluetooth headset
  • Calibration certificate
  • FLIR Tools+ license card
  • Hard transport case
  • HDMI-HDMI cable
  • Lens cap
  • Memory card
  • Neck strap
  • Power supply, including multi-plugs
  • Printed documentation
  • USB cable, Std A to Micro-B

EAN-13 7332558010273

UPC-12 845188010911

Country of origin Sweden

Supplies & accessories:

  • T199064; IR lens f=36mm (28°) with case
  • T199066; IR lens f=21.2mm (45°) with case
  • T199077; IR lens f=83.4mm (12°) with case
  • T910814; Power supply, incl. multi plugs
  • T198126; Battery charger, incl. power supply with multi plugs T6xx
  • T198506; Li-Ion Battery pack 3.7V 29Wh
  • T199406ACC; Battery Li-ion 3.7 V, 7.8 Ah, 29 Wh
  • T911230ACC; Memory card SDHC 4 GB
  • T198509; Cigarette lighter adapter kit, 12 VDC, 1.2 m/3.9 ft.
  • T910930ACC; HDMI type C to DVI cable 1.5 m
  • T910891ACC; HDMI type C to HDMI type A cable 1.5 m
  • T198497; Large eyecup
  • T197771ACC; Bluetooth Headset
Show 6 more labels / short text on this page
Environmental data · Safety EN/UL/CSA/PSE 60950-1 · Physical data · Housing material Magnesium · Warranty information · Shipping information
Page 109 of the Flir T1020 user manual — 26.4 FLIR T1020 12°
Page 109 · click to enlarge
Page 109
  • T911093; Tool belt
  • T198533; USB cable Std A <-> Micro B
  • T198586; FLIR Reporter Professional (license only)
  • T198584; FLIR Tools
  • T198583; FLIR Tools+ (download card incl. license key)
  • DSW-10000; FLIR IR Camera Player
  • APP-10002; FLIR Tools Mobile (Android Application)
  • APP-10003; FLIR Tools Mobile (iPad/iPhone Application)
  • APP-10004; FLIR Tools (MacOS Application)
  • T199233; FLIR Atlas SDK for .NET
  • T199234; FLIR Atlas SDK for MATLAB
Page 110 of the Flir T1020 user manual — 26.5 FLIR T1020 28°
Page 110 · click to enlarge
Page 110

26.5 FLIR T1020 28°

P/N72501-0102 Rev.: 36730

The FLIR T1020 is designed for the expert requiring the highest performance and the latest technology available. The camera combines excellent ergonomics and feature-rich flexibility with superior image quality at an infrared resolution of 1024 × 768 pixels.

Benefits:

  • Flexible and feature rich: A wide variety of measuring and analysis functions make the FLIR T1020 flexible for your every need. Two programmable buttons provide easy access to favorite functions.
  • Highest performance with the latest technology: The FLIR T1020 is equipped with the innovative Multi Spectral Dynamic Imaging (MSX) feature, which produces an image richer in detail than ever before. With its continuous autofocus, the FLIR T1020 is a fully automatic infrared camera.
  • Support for UltraMax: When enabling UltraMax in the camera, the resolution of images can be substantially enhanced when importing the images into FLIR Tools.

Imaging and optical data

IR resolution 1024 × 768 pixels

MSX resolution 1024 × 768 pixels

Thermal sensitivity/NETD

Field of view (FOV) 28° × 21°

Minimum IR focus distance 0.4 m (1.32 ft.)

Minimum IR–visual alignment distance 0.4 m (1.32 ft.)

Focal length 36 mm (1.42 in.)

Spatial resolution (IFOV) 0.47 mrad

F-number 1.15

Image frequency 30 Hz

Focus One shot or manual

Digital zoom 1–8× continuous

Digital image enhancement Adaptive digital noise reduction

Detector type Focal plane array (FPA), uncooled microbolometer

Spectral range 7.5–14 µm

Detector pitch 17 µm

Display Built-in touch screen, 4.3 in. wide screen LCD, 800 × 480 pixels

Display type Capacitive touch screen

Auto orientation Automatic landscape or portrait

Viewfinder Built-in 800 × 480 pixels

Automatic image adjustment Continuous, histogram based

Show 5 more labels / short text on this page
General description · UltraMax Yes · Lens identification Automatic · Detector data · Image presentation
Page 111 of the Flir T1020 user manual — NOTE
Page 111 · click to enlarge
Page 111

Automatic image adjustment, type Standard or histogram based on the image content

Manual image adjustment Linear based, possible to adjust level/span/max./ min.

Image modes Thermal, thermal MSX, picture in picture, digital camera

Infrared image Full color infrared image

Visual image Full color visual image

Multi Spectral Dynamic Imaging (MSX) Thermal image with enhanced detail presentation

Picture in Picture Resizable and movable infrared area on the visual image

  • Gallery
  • Review thumbnail/full image on the camera
  • Edit measurements/palettes/image modes on the camera
  • Object temperature range
  • –40 to +150°C (–40 to +302°F)
  • 0 to +650°C (+32 to +1202°F)
  • +300 to +2000°C (+572 to +3632°F)
  • Accuracy
  • ±1°C (±1.8°F) or ±1% @ 25°C (77°F) for temperatures between 5 and 150°C (41 and 302° F), in range –40 to 150°C (–40 to 302°F)
  • ±2°C (±3.6°F) or ±2% of reading @ 25°C (77° F) for temperatures between –40 and 2000°C (–40 and 3632°F)

NOTE

For HSI use, above 30 Hz frame rate, the typical accuracy will be ±2.5°C (±4.5°F), or 2.5% of reading @ 25°C (77°F).

Area 5 + 5 areas (boxes and circles) with max./min./ average

Profile 1 line profile with max./min. temperature

Automatic hot/cold detection Auto hot or cold spotmeter markers within the area and profile

Measurement presets No measurements, Center spot, Hot spot, Cold spot, User preset 1, User preset 2

User presets The user can select and combine measurements from any number of spots/boxes/circles/profiles/ delta

Difference temperature Delta temperature between the measurement func- tions and the reference temperature

Reference temperature Manually set using the difference temperature

Atmospheric transmission correction Automatic, based on the inputs for distance, at- mospheric temperature, and relative humidity

Optics transmission correction Automatic, based on signals from internal sensors

Show 5 more labels / short text on this page
Image presentation · Image presentation modes · Measurement · Measurement analysis · Spotmeter 10
Page 112 of the Flir T1020 user manual — 26.5 FLIR T1020 28°
Page 112 · click to enlarge
Page 112

Emissivity correction Variable from 0.01 to 1.0 or selected from the ma- terials list

Reflected apparent temperature correction Automatic, based on the input of the reflected temperature

External optics/windows correction Automatic, based on the inputs of the window transmission and temperature

Measurement corrections Emissivity, reflected temperature, relative humidity, atmospheric temperature, object distance, external infrared window compensation

Colors (palettes) Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava

Color Alarm (isotherm) Above/below/interval

Measurement function alarm Audible/visual alarms (above/below) on any se- lected measurement function

Set-up commands Define user presets, Save options, Programmable button, Reset options, Set up camera, Wi-Fi, GPS & compass, Bluetooth, Language, Time & units, Camera information

Languages Arabic, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japa- nese, Korean, Norwegian, Polish, Portuguese, Russian, simplified Chinese, Swedish, traditional Chinese, Turkish

Camera software update Use PC software FLIR Tools

Image storage Standard JPEG, including digital image and meas- urement data, on a memory card

Storage media Removable media SD or SDHC card. Class 10 or better recommended

  • Image storage mode
  • Simultaneous storage of thermal and digital images in the same JPEG file
  • Option to store a digital photo as a separate JPEG file

Time lapse 15 seconds to 24 hours

  • File formats
  • Standard JPEG, measurement data included
  • CSQ, measurement data included

File formats, visual Standard JPEG, automatically associated with the corresponding thermal image

Voice 60 seconds (via Bluetooth) stored with the image

Text Add table, select between predefined templates

Show 6 more labels / short text on this page
Measurement analysis · Alarm · Set-up · Service functions · Storage of images · Image annotations
Page 113 of the Flir T1020 user manual — 26.5 FLIR T1020 28°
Page 113 · click to enlarge
Page 113

Image description Add short note (stored in the JPEG exif tag)

  • Sketch
  • Draw on the thermal/digital image or add predefined stamps
  • Separate PC software with extensive report generation

GPS Location data automatically added to every image from the built-in GPS

Compass Camera direction automatically added to every image

Video recording in camera

Radiometric IR-video recording Real-time radiometric recording (RTRR) to the memory card

Non-radiometric IR-video recording H.264 to the memory card

Visual video recording H.264 to the memory card

Radiometric IR-video streaming Real-time radiometric streaming (RTRS) via USB

  • Non-radiometric IR-video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Visual video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB

Digital camera Field of view adapts to the infrared lens

Video lamp Built-in LED light

Laser Activated by a dedicated button

Laser alignment Position is automatically displayed on the infrared image

Laser classification Class 2

Laser type Semiconductor AlGaInP diode laser, 1 mW, 635 nm (red)

Interfaces USB Micro-B, Bluetooth, Wi-Fi, HDMI

Bluetooth Communication with a headset

Wi-Fi Infrastructure (network) or AP

SD Card One card slot for removable SD memory cards

Audio Microphone headset via Bluetooth for the voice an- notation of images

Show 6 more labels / short text on this page
Image annotations · Geographic Information System · Video streaming · Digital camera · Laser pointer · Data communication interfaces
Page 114 of the Flir T1020 user manual — USB
Page 114 · click to enlarge
Page 114

USB

USB USB Micro-Bdata transfer to and from a PC, uncompressed colorized video
  • USB, standard
  • USB 2.0 High Speed
  • USB Micro-B connector
  • Video out
  • HDMI 640 × 480
  • HDMI 1280 × 720
  • DVI 640 × 480
  • DVI 800 × 600

Video, connector type HDMI type C

  • Wi-Fi
  • Standard: 802.11 b/g/n
  • Frequency range: 2412–2462 MHz
  • Max. output power: 15 dBm
Bluetooth Frequency range2402–2480 MHz, supports 2.1, 4.0, and 4.0 BLE

Battery type Rechargeable Li ion battery

Battery operating time >2.5 hours at 25°C (+68°F) and typical use

Charging system In camera (AC adapter or 12 V from a vehicle) or two-bay charger

Charging time 2.5 hours to 90% capacity, charging status indi- cated by LEDs

Charging temperature 0–45°C (32–113°F)

External power operation AC adapter 90–260 V AC, 50/60 Hz or 12 V from a vehicle (cable with a standard plug, optional)

Power management Automatic power-off functionality, user configura- ble between 5 minutes, 20 minutes, and no auto- matic shutdown

Operating temperature range –15°C to +50°C (+5°F to +122°F)

Storage temperature range –40 to +70°C (–40 to +158°F)

Humidity (operating and storage) IEC 60068-2-30 / 24 hours, 95% relative humidity, 25–40°C (77–104°F) / 2 cycles

  • EMC
  • ETSI EN 301 489-1 (radio)
  • ETSI EN 301 489-17
  • EN 61000-6-2 (Immunity)
  • EN 61000-6-3 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
  • ICES-003
  • Radio spectrum
  • ETSI EN 300 328
  • FCC Part 15.247
  • RSS-247 issue 1

Encapsulation IP 54 (IEC 60529)

Shock 25 g (IEC 60068-2-29)

Show 5 more labels / short text on this page
Video · Radio · Antenna Internal · Power system · Environmental data
Page 115 of the Flir T1020 user manual — Supplies & accessories:
Page 115 · click to enlarge
Page 115

Vibration 2 g (IEC 60068-2-6)

Ergonomics The viewfinder plus the 120° rotating optical block allow you to point the camera in multiple directions while maintaining a comfortable position

Weight 1.9 kg (4.3 lb.)

Camera size, excl. lens (L × W × H) 167.2 mm × 204.5 mm × 188.3 mm (6.6 in. × 8.0 in. × 7.4 in.)

Tripod mounting UNC ¼"-20

  • Warranty
  • 2 years parts and labor coverage on the camera
  • 5 years coverage on the battery
  • 10 years coverage on the detector – the most vital part of the whole camera
  • List of contents
  • Infrared camera with lens
  • Battery (2 ea.)
  • Battery charger
  • Bluetooth headset
  • Calibration certificate
  • FLIR Tools+ license card
  • Hard transport case
  • HDMI-HDMI cable
  • Lens cap
  • Memory card
  • Neck strap
  • Power supply, including multi-plugs
  • Printed documentation
  • USB cable, Std A to Micro-B

EAN-13 7332558010280

UPC-12 845188010928

Country of origin Sweden

Supplies & accessories:

  • T199064; IR lens f=36mm (28°) with case
  • T199066; IR lens f=21.2mm (45°) with case
  • T199077; IR lens f=83.4mm (12°) with case
  • T910814; Power supply, incl. multi plugs
  • T198126; Battery charger, incl. power supply with multi plugs T6xx
  • T198506; Li-Ion Battery pack 3.7V 29Wh
  • T199406ACC; Battery Li-ion 3.7 V, 7.8 Ah, 29 Wh
  • T911230ACC; Memory card SDHC 4 GB
  • T198509; Cigarette lighter adapter kit, 12 VDC, 1.2 m/3.9 ft.
  • T910930ACC; HDMI type C to DVI cable 1.5 m
  • T910891ACC; HDMI type C to HDMI type A cable 1.5 m
  • T198497; Large eyecup
  • T197771ACC; Bluetooth Headset
Show 6 more labels / short text on this page
Environmental data · Safety EN/UL/CSA/PSE 60950-1 · Physical data · Housing material Magnesium · Warranty information · Shipping information
Page 116 of the Flir T1020 user manual — 26.5 FLIR T1020 28°
Page 116 · click to enlarge
Page 116
  • T911093; Tool belt
  • T198533; USB cable Std A <-> Micro B
  • T198586; FLIR Reporter Professional (license only)
  • T198584; FLIR Tools
  • T198583; FLIR Tools+ (download card incl. license key)
  • DSW-10000; FLIR IR Camera Player
  • APP-10002; FLIR Tools Mobile (Android Application)
  • APP-10003; FLIR Tools Mobile (iPad/iPhone Application)
  • APP-10004; FLIR Tools (MacOS Application)
  • T199233; FLIR Atlas SDK for .NET
  • T199234; FLIR Atlas SDK for MATLAB
Page 117 of the Flir T1020 user manual — 26.6 FLIR T1020 45°
Page 117 · click to enlarge
Page 117

26.6 FLIR T1020 45°

P/N72501-0103 Rev.: 36730

The FLIR T1020 is designed for the expert requiring the highest performance and the latest technology available. The camera combines excellent ergonomics and feature-rich flexibility with superior image quality at an infrared resolution of 1024 × 768 pixels.

Benefits:

  • Flexible and feature rich: A wide variety of measuring and analysis functions make the FLIR T1020 flexible for your every need. Two programmable buttons provide easy access to favorite functions.
  • Highest performance with the latest technology: The FLIR T1020 is equipped with the innovative Multi Spectral Dynamic Imaging (MSX) feature, which produces an image richer in detail than ever before. With its continuous autofocus, the FLIR T1020 is a fully automatic infrared camera.
  • Support for UltraMax: When enabling UltraMax in the camera, the resolution of images can be substantially enhanced when importing the images into FLIR Tools.

Imaging and optical data

IR resolution 1024 × 768 pixels

MSX resolution 1024 × 768 pixels

Thermal sensitivity/NETD

Field of view (FOV) 45° × 34°

Minimum IR focus distance 0.2 m (0.66 ft.)

Minimum IR–visual alignment distance 0.5 m (1.64 ft.)

Focal length 21.2 mm (0.83 in.)

Spatial resolution (IFOV) 0.80 mrad

F-number 1.1

Image frequency 30 Hz

Focus One shot or manual

Digital zoom 1–8× continuous

Digital image enhancement Adaptive digital noise reduction

Detector type Focal plane array (FPA), uncooled microbolometer

Spectral range 7.5–14 µm

Detector pitch 17 µm

Display Built-in touch screen, 4.3 in. wide screen LCD, 800 × 480 pixels

Display type Capacitive touch screen

Auto orientation Automatic landscape or portrait

Viewfinder Built-in 800 × 480 pixels

Automatic image adjustment Continuous, histogram based

Show 5 more labels / short text on this page
General description · UltraMax Yes · Lens identification Automatic · Detector data · Image presentation
Page 118 of the Flir T1020 user manual — NOTE
Page 118 · click to enlarge
Page 118

Automatic image adjustment, type Standard or histogram based on the image content

Manual image adjustment Linear based, possible to adjust level/span/max./ min.

Image modes Thermal, thermal MSX, picture in picture, digital camera

Infrared image Full color infrared image

Visual image Full color visual image

Multi Spectral Dynamic Imaging (MSX) Thermal image with enhanced detail presentation

Picture in Picture Resizable and movable infrared area on the visual image

  • Gallery
  • Review thumbnail/full image on the camera
  • Edit measurements/palettes/image modes on the camera
  • Object temperature range
  • –40 to +150°C (–40 to +302°F)
  • 0 to +650°C (+32 to +1202°F)
  • +300 to +2000°C (+572 to +3632°F)
  • Accuracy
  • ±1°C (±1.8°F) or ±1% @ 25°C (77°F) for temperatures between 5 and 150°C (41 and 302° F), in range –40 to 150°C (–40 to 302°F)
  • ±2°C (±3.6°F) or ±2% of reading @ 25°C (77° F) for temperatures between –40 and 2000°C (–40 and 3632°F)

NOTE

For HSI use, above 30 Hz frame rate, the typical accuracy will be ±2.5°C (±4.5°F), or 2.5% of reading @ 25°C (77°F).

Area 5 + 5 areas (boxes and circles) with max./min./ average

Profile 1 line profile with max./min. temperature

Automatic hot/cold detection Auto hot or cold spotmeter markers within the area and profile

Measurement presets No measurements, Center spot, Hot spot, Cold spot, User preset 1, User preset 2

User presets The user can select and combine measurements from any number of spots/boxes/circles/profiles/ delta

Difference temperature Delta temperature between the measurement func- tions and the reference temperature

Reference temperature Manually set using the difference temperature

Atmospheric transmission correction Automatic, based on the inputs for distance, at- mospheric temperature, and relative humidity

Optics transmission correction Automatic, based on signals from internal sensors

Show 5 more labels / short text on this page
Image presentation · Image presentation modes · Measurement · Measurement analysis · Spotmeter 10
Page 119 of the Flir T1020 user manual — 26.6 FLIR T1020 45°
Page 119 · click to enlarge
Page 119

Emissivity correction Variable from 0.01 to 1.0 or selected from the ma- terials list

Reflected apparent temperature correction Automatic, based on the input of the reflected temperature

External optics/windows correction Automatic, based on the inputs of the window transmission and temperature

Measurement corrections Emissivity, reflected temperature, relative humidity, atmospheric temperature, object distance, external infrared window compensation

Colors (palettes) Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava

Color Alarm (isotherm) Above/below/interval

Measurement function alarm Audible/visual alarms (above/below) on any se- lected measurement function

Set-up commands Define user presets, Save options, Programmable button, Reset options, Set up camera, Wi-Fi, GPS & compass, Bluetooth, Language, Time & units, Camera information

Languages Arabic, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japa- nese, Korean, Norwegian, Polish, Portuguese, Russian, simplified Chinese, Swedish, traditional Chinese, Turkish

Camera software update Use PC software FLIR Tools

Image storage Standard JPEG, including digital image and meas- urement data, on a memory card

Storage media Removable media SD or SDHC card. Class 10 or better recommended

  • Image storage mode
  • Simultaneous storage of thermal and digital images in the same JPEG file
  • Option to store a digital photo as a separate JPEG file

Time lapse 15 seconds to 24 hours

  • File formats
  • Standard JPEG, measurement data included
  • CSQ, measurement data included

File formats, visual Standard JPEG, automatically associated with the corresponding thermal image

Voice 60 seconds (via Bluetooth) stored with the image

Text Add table, select between predefined templates

Show 6 more labels / short text on this page
Measurement analysis · Alarm · Set-up · Service functions · Storage of images · Image annotations
Page 120 of the Flir T1020 user manual — 26.6 FLIR T1020 45°
Page 120 · click to enlarge
Page 120

Image description Add short note (stored in the JPEG exif tag)

  • Sketch
  • Draw on the thermal/digital image or add predefined stamps
  • Separate PC software with extensive report generation

GPS Location data automatically added to every image from the built-in GPS

Compass Camera direction automatically added to every image

Video recording in camera

Radiometric IR-video recording Real-time radiometric recording (RTRR) to the memory card

Non-radiometric IR-video recording H.264 to the memory card

Visual video recording H.264 to the memory card

Radiometric IR-video streaming Real-time radiometric streaming (RTRS) via USB

  • Non-radiometric IR-video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Visual video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB

Digital camera Field of view adapts to the infrared lens

Video lamp Built-in LED light

Laser Activated by a dedicated button

Laser alignment Position is automatically displayed on the infrared image

Laser classification Class 2

Laser type Semiconductor AlGaInP diode laser, 1 mW, 635 nm (red)

Interfaces USB Micro-B, Bluetooth, Wi-Fi, HDMI

Bluetooth Communication with a headset

Wi-Fi Infrastructure (network) or AP

SD Card One card slot for removable SD memory cards

Audio Microphone headset via Bluetooth for the voice an- notation of images

Show 6 more labels / short text on this page
Image annotations · Geographic Information System · Video streaming · Digital camera · Laser pointer · Data communication interfaces
Page 121 of the Flir T1020 user manual — USB
Page 121 · click to enlarge
Page 121

USB

USB USB Micro-Bdata transfer to and from a PC, uncompressed colorized video
  • USB, standard
  • USB 2.0 High Speed
  • USB Micro-B connector
  • Video out
  • HDMI 640 × 480
  • HDMI 1280 × 720
  • DVI 640 × 480
  • DVI 800 × 600

Video, connector type HDMI type C

  • Wi-Fi
  • Standard: 802.11 b/g/n
  • Frequency range: 2412–2462 MHz
  • Max. output power: 15 dBm
Bluetooth Frequency range2402–2480 MHz, supports 2.1, 4.0, and 4.0 BLE

Battery type Rechargeable Li ion battery

Battery operating time >2.5 hours at 25°C (+68°F) and typical use

Charging system In camera (AC adapter or 12 V from a vehicle) or two-bay charger

Charging time 2.5 hours to 90% capacity, charging status indi- cated by LEDs

Charging temperature 0–45°C (32–113°F)

External power operation AC adapter 90–260 V AC, 50/60 Hz or 12 V from a vehicle (cable with a standard plug, optional)

Power management Automatic power-off functionality, user configura- ble between 5 minutes, 20 minutes, and no auto- matic shutdown

Operating temperature range –15°C to +50°C (+5°F to +122°F)

Storage temperature range –40 to +70°C (–40 to +158°F)

Humidity (operating and storage) IEC 60068-2-30 / 24 hours, 95% relative humidity, 25–40°C (77–104°F) / 2 cycles

  • EMC
  • ETSI EN 301 489-1 (radio)
  • ETSI EN 301 489-17
  • EN 61000-6-2 (Immunity)
  • EN 61000-6-3 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
  • ICES-003
  • Radio spectrum
  • ETSI EN 300 328
  • FCC Part 15.247
  • RSS-247 issue 1

Encapsulation IP 54 (IEC 60529)

Shock 25 g (IEC 60068-2-29)

Show 5 more labels / short text on this page
Video · Radio · Antenna Internal · Power system · Environmental data
Page 122 of the Flir T1020 user manual — Supplies & accessories:
Page 122 · click to enlarge
Page 122

Vibration 2 g (IEC 60068-2-6)

Ergonomics The viewfinder plus the 120° rotating optical block allow you to point the camera in multiple directions while maintaining a comfortable position

Weight 2.0 kg (4.3 lb.)

Camera size, excl. lens (L × W × H) 167.2 mm × 204.5 mm × 188.3 mm (6.6 in. × 8.0 in. × 7.4 in.)

Tripod mounting UNC ¼"-20

  • Warranty
  • 2 years parts and labor coverage on the camera
  • 5 years coverage on the battery
  • 10 years coverage on the detector – the most vital part of the whole camera
  • List of contents
  • Infrared camera with lens
  • Battery (2 ea.)
  • Battery charger
  • Bluetooth headset
  • Calibration certificate
  • FLIR Tools+ license card
  • Hard transport case
  • HDMI-HDMI cable
  • Lens cap
  • Memory card
  • Neck strap
  • Power supply, including multi-plugs
  • Printed documentation
  • USB cable, Std A to Micro-B

EAN-13 7332558010297

UPC-12 845188010935

Country of origin Sweden

Supplies & accessories:

  • T199064; IR lens f=36mm (28°) with case
  • T199066; IR lens f=21.2mm (45°) with case
  • T199077; IR lens f=83.4mm (12°) with case
  • T910814; Power supply, incl. multi plugs
  • T198126; Battery charger, incl. power supply with multi plugs T6xx
  • T198506; Li-Ion Battery pack 3.7V 29Wh
  • T199406ACC; Battery Li-ion 3.7 V, 7.8 Ah, 29 Wh
  • T911230ACC; Memory card SDHC 4 GB
  • T198509; Cigarette lighter adapter kit, 12 VDC, 1.2 m/3.9 ft.
  • T910930ACC; HDMI type C to DVI cable 1.5 m
  • T910891ACC; HDMI type C to HDMI type A cable 1.5 m
  • T198497; Large eyecup
  • T197771ACC; Bluetooth Headset
Show 6 more labels / short text on this page
Environmental data · Safety EN/UL/CSA/PSE 60950-1 · Physical data · Housing material Magnesium · Warranty information · Shipping information
Page 123 of the Flir T1020 user manual — 26.6 FLIR T1020 45°
Page 123 · click to enlarge
Page 123
  • T911093; Tool belt
  • T198533; USB cable Std A <-> Micro B
  • T198586; FLIR Reporter Professional (license only)
  • T198584; FLIR Tools
  • T198583; FLIR Tools+ (download card incl. license key)
  • DSW-10000; FLIR IR Camera Player
  • APP-10002; FLIR Tools Mobile (Android Application)
  • APP-10003; FLIR Tools Mobile (iPad/iPhone Application)
  • APP-10004; FLIR Tools (MacOS Application)
  • T199233; FLIR Atlas SDK for .NET
  • T199234; FLIR Atlas SDK for MATLAB
Page 124 of the Flir T1020 user manual — 26.7 FLIR T1020 28° and 12°
Page 124 · click to enlarge
Page 124

26.7 FLIR T1020 28° and 12°

P/N72501-0104 Rev.: 36730

The FLIR T1020 is designed for the expert requiring the highest performance and the latest technology available. The camera combines excellent ergonomics and feature-rich flexibility with superior image quality at an infrared resolution of 1024 × 768 pixels.

Benefits:

  • Flexible and feature rich: A wide variety of measuring and analysis functions make the FLIR T1020 flexible for your every need. Two programmable buttons provide easy access to favorite functions.
  • Highest performance with the latest technology: The FLIR T1020 is equipped with the innovative Multi Spectral Dynamic Imaging (MSX) feature, which produces an image richer in detail than ever before. With its continuous autofocus, the FLIR T1020 is a fully automatic infrared camera.
  • Support for UltraMax: When enabling UltraMax in the camera, the resolution of images can be substantially enhanced when importing the images into FLIR Tools.

Imaging and optical data

IR resolution 1024 × 768 pixels

MSX resolution 1024 × 768 pixels

Thermal sensitivity/NETD

Field of view (FOV) 28° × 21°

Minimum IR focus distance 0.4 m (1.32 ft.)

Minimum IR–visual alignment distance 0.4 m (1.32 ft.)

Focal length 36 mm (1.42 in.)

Spatial resolution (IFOV) 0.47 mrad

F-number 1.15

Image frequency 30 Hz

Focus One shot or manual

Digital zoom 1–8× continuous

Digital image enhancement Adaptive digital noise reduction

Detector type Focal plane array (FPA), uncooled microbolometer

Spectral range 7.5–14 µm

Detector pitch 17 µm

Display Built-in touch screen, 4.3 in. wide screen LCD, 800 × 480 pixels

Display type Capacitive touch screen

Auto orientation Automatic landscape or portrait

Viewfinder Built-in 800 × 480 pixels

Automatic image adjustment Continuous, histogram based

Show 5 more labels / short text on this page
General description · UltraMax Yes · Lens identification Automatic · Detector data · Image presentation
Page 125 of the Flir T1020 user manual — NOTE
Page 125 · click to enlarge
Page 125

Automatic image adjustment, type Standard or histogram based on the image content

Manual image adjustment Linear based, possible to adjust level/span/max./ min.

Image modes Thermal, thermal MSX, picture in picture, digital camera

Infrared image Full color infrared image

Visual image Full color visual image

Multi Spectral Dynamic Imaging (MSX) Thermal image with enhanced detail presentation

Picture in Picture Resizable and movable infrared area on the visual image

  • Gallery
  • Review thumbnail/full image on the camera
  • Edit measurements/palettes/image modes on the camera
  • Object temperature range
  • –40 to +150°C (–40 to +302°F)
  • 0 to +650°C (+32 to +1202°F)
  • +300 to +2000°C (+572 to +3632°F)
  • Accuracy
  • ±1°C (±1.8°F) or ±1% @ 25°C (77°F) for temperatures between 5 and 150°C (41 and 302° F), in range –40 to 150°C (–40 to 302°F)
  • ±2°C (±3.6°F) or ±2% of reading @ 25°C (77° F) for temperatures between –40 and 2000°C (–40 and 3632°F)

NOTE

For HSI use, above 30 Hz frame rate, the typical accuracy will be ±2.5°C (±4.5°F), or 2.5% of reading @ 25°C (77°F).

Area 5 + 5 areas (boxes and circles) with max./min./ average

Profile 1 line profile with max./min. temperature

Automatic hot/cold detection Auto hot or cold spotmeter markers within the area and profile

Measurement presets No measurements, Center spot, Hot spot, Cold spot, User preset 1, User preset 2

User presets The user can select and combine measurements from any number of spots/boxes/circles/profiles/ delta

Difference temperature Delta temperature between the measurement func- tions and the reference temperature

Reference temperature Manually set using the difference temperature

Atmospheric transmission correction Automatic, based on the inputs for distance, at- mospheric temperature, and relative humidity

Optics transmission correction Automatic, based on signals from internal sensors

Show 5 more labels / short text on this page
Image presentation · Image presentation modes · Measurement · Measurement analysis · Spotmeter 10
Page 126 of the Flir T1020 user manual — 26.7 FLIR T1020 28° and 12°
Page 126 · click to enlarge
Page 126

Emissivity correction Variable from 0.01 to 1.0 or selected from the ma- terials list

Reflected apparent temperature correction Automatic, based on the input of the reflected temperature

External optics/windows correction Automatic, based on the inputs of the window transmission and temperature

Measurement corrections Emissivity, reflected temperature, relative humidity, atmospheric temperature, object distance, external infrared window compensation

Colors (palettes) Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava

Color Alarm (isotherm) Above/below/interval

Measurement function alarm Audible/visual alarms (above/below) on any se- lected measurement function

Set-up commands Define user presets, Save options, Programmable button, Reset options, Set up camera, Wi-Fi, GPS & compass, Bluetooth, Language, Time & units, Camera information

Languages Arabic, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japa- nese, Korean, Norwegian, Polish, Portuguese, Russian, simplified Chinese, Swedish, traditional Chinese, Turkish

Camera software update Use PC software FLIR Tools

Image storage Standard JPEG, including digital image and meas- urement data, on a memory card

Storage media Removable media SD or SDHC card. Class 10 or better recommended

  • Image storage mode
  • Simultaneous storage of thermal and digital images in the same JPEG file
  • Option to store a digital photo as a separate JPEG file

Time lapse 15 seconds to 24 hours

  • File formats
  • Standard JPEG, measurement data included
  • CSQ, measurement data included

File formats, visual Standard JPEG, automatically associated with the corresponding thermal image

Voice 60 seconds (via Bluetooth) stored with the image

Text Add table, select between predefined templates

Show 6 more labels / short text on this page
Measurement analysis · Alarm · Set-up · Service functions · Storage of images · Image annotations
Page 127 of the Flir T1020 user manual — 26.7 FLIR T1020 28° and 12°
Page 127 · click to enlarge
Page 127

Image description Add short note (stored in the JPEG exif tag)

  • Sketch
  • Draw on the thermal/digital image or add predefined stamps
  • Separate PC software with extensive report generation

GPS Location data automatically added to every image from the built-in GPS

Compass Camera direction automatically added to every image

Video recording in camera

Radiometric IR-video recording Real-time radiometric recording (RTRR) to the memory card

Non-radiometric IR-video recording H.264 to the memory card

Visual video recording H.264 to the memory card

Radiometric IR-video streaming Real-time radiometric streaming (RTRS) via USB

  • Non-radiometric IR-video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Visual video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB

Digital camera Field of view adapts to the infrared lens

Video lamp Built-in LED light

Laser Activated by a dedicated button

Laser alignment Position is automatically displayed on the infrared image

Laser classification Class 2

Laser type Semiconductor AlGaInP diode laser, 1 mW, 635 nm (red)

Interfaces USB Micro-B, Bluetooth, Wi-Fi, HDMI

Bluetooth Communication with a headset

Wi-Fi Infrastructure (network) or AP

SD Card One card slot for removable SD memory cards

Audio Microphone headset via Bluetooth for the voice an- notation of images

Show 6 more labels / short text on this page
Image annotations · Geographic Information System · Video streaming · Digital camera · Laser pointer · Data communication interfaces
Page 128 of the Flir T1020 user manual — USB
Page 128 · click to enlarge
Page 128

USB

USB USB Micro-Bdata transfer to and from a PC, uncompressed colorized video
  • USB, standard
  • USB 2.0 High Speed
  • USB Micro-B connector
  • Video out
  • HDMI 640 × 480
  • HDMI 1280 × 720
  • DVI 640 × 480
  • DVI 800 × 600

Video, connector type HDMI type C

  • Wi-Fi
  • Standard: 802.11 b/g/n
  • Frequency range: 2412–2462 MHz
  • Max. output power: 15 dBm
Bluetooth Frequency range2402–2480 MHz, supports 2.1, 4.0, and 4.0 BLE

Battery type Rechargeable Li ion battery

Battery operating time >2.5 hours at 25°C (+68°F) and typical use

Charging system In camera (AC adapter or 12 V from a vehicle) or two-bay charger

Charging time 2.5 hours to 90% capacity, charging status indi- cated by LEDs

Charging temperature 0–45°C (32–113°F)

External power operation AC adapter 90–260 V AC, 50/60 Hz or 12 V from a vehicle (cable with a standard plug, optional)

Power management Automatic power-off functionality, user configura- ble between 5 minutes, 20 minutes, and no auto- matic shutdown

Operating temperature range –15°C to +50°C (+5°F to +122°F)

Storage temperature range –40 to +70°C (–40 to +158°F)

Humidity (operating and storage) IEC 60068-2-30 / 24 hours, 95% relative humidity, 25–40°C (77–104°F) / 2 cycles

  • EMC
  • ETSI EN 301 489-1 (radio)
  • ETSI EN 301 489-17
  • EN 61000-6-2 (Immunity)
  • EN 61000-6-3 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
  • ICES-003
  • Radio spectrum
  • ETSI EN 300 328
  • FCC Part 15.247
  • RSS-247 issue 1

Encapsulation IP 54 (IEC 60529)

Shock 25 g (IEC 60068-2-29)

Show 5 more labels / short text on this page
Video · Radio · Antenna Internal · Power system · Environmental data
Page 129 of the Flir T1020 user manual — Supplies & accessories:
Page 129 · click to enlarge
Page 129

Vibration 2 g (IEC 60068-2-6)

Ergonomics The viewfinder plus the 120° rotating optical block allow you to point the camera in multiple directions while maintaining a comfortable position

Weight 1.9 kg (4.3 lb.)

Camera size, excl. lens (L × W × H) 167.2 mm × 204.5 mm × 188.3 mm (6.6 in. × 8.0 in. × 7.4 in.)

Tripod mounting UNC ¼"-20

  • Warranty
  • 2 years parts and labor coverage on the camera
  • 5 years coverage on the battery
  • 10 years coverage on the detector – the most vital part of the whole camera

Packaging, type Cardboard box

  • List of contents
  • Infrared camera with lens
  • Battery (2 ea.)
  • Battery charger
  • Bluetooth headset
  • Calibration certificate
  • FLIR Tools+ license card
  • Hard transport case
  • HDMI-HDMI cable
  • IR lens, 12°
  • Lens cap
  • Memory card
  • Neck strap
  • Power supply, including multi-plugs
  • Printed documentation
  • USB cable, Std A to Micro-B

Packaging, weight 7.2 kg (15.8 lb.)

Packaging, size 494 × 355 × 188 mm (19.4 × 14.0 × 7.4 in.)

EAN-13 7332558011287

UPC-12 845188012168

Country of origin Sweden

Supplies & accessories:

  • T199064; IR lens f=36mm (28°) with case
  • T199066; IR lens f=21.2mm (45°) with case
  • T199077; IR lens f=83.4mm (12°) with case
  • T910814; Power supply, incl. multi plugs
  • T198126; Battery charger, incl. power supply with multi plugs T6xx
  • T198506; Li-Ion Battery pack 3.7V 29Wh
  • T199406ACC; Battery Li-ion 3.7 V, 7.8 Ah, 29 Wh
  • T911230ACC; Memory card SDHC 4 GB
Show 6 more labels / short text on this page
Environmental data · Safety EN/UL/CSA/PSE 60950-1 · Physical data · Housing material Magnesium · Warranty information · Shipping information
Page 130 of the Flir T1020 user manual — 26.7 FLIR T1020 28° and 12°
Page 130 · click to enlarge
Page 130
  • T198509; Cigarette lighter adapter kit, 12 VDC, 1.2 m/3.9 ft.
  • T910930ACC; HDMI type C to DVI cable 1.5 m
  • T910891ACC; HDMI type C to HDMI type A cable 1.5 m
  • T198497; Large eyecup
  • T197771ACC; Bluetooth Headset
  • T911093; Tool belt
  • T198533; USB cable Std A <-> Micro B
  • T198586; FLIR Reporter Professional (license only)
  • T198584; FLIR Tools
  • T198583; FLIR Tools+ (download card incl. license key)
  • DSW-10000; FLIR IR Camera Player
  • APP-10002; FLIR Tools Mobile (Android Application)
  • APP-10003; FLIR Tools Mobile (iPad/iPhone Application)
  • APP-10004; FLIR Tools (MacOS Application)
  • T199233; FLIR Atlas SDK for .NET
  • T199234; FLIR Atlas SDK for MATLAB
Page 131 of the Flir T1020 user manual — 26.8 FLIR T1020 28° and 45°
Page 131 · click to enlarge
Page 131

26.8 FLIR T1020 28° and 45°

P/N72501-0105 Rev.: 36730

The FLIR T1020 is designed for the expert requiring the highest performance and the latest technology available. The camera combines excellent ergonomics and feature-rich flexibility with superior image quality at an infrared resolution of 1024 × 768 pixels.

Benefits:

  • Flexible and feature rich: A wide variety of measuring and analysis functions make the FLIR T1020 flexible for your every need. Two programmable buttons provide easy access to favorite functions.
  • Highest performance with the latest technology: The FLIR T1020 is equipped with the innovative Multi Spectral Dynamic Imaging (MSX) feature, which produces an image richer in detail than ever before. With its continuous autofocus, the FLIR T1020 is a fully automatic infrared camera.
  • Support for UltraMax: When enabling UltraMax in the camera, the resolution of images can be substantially enhanced when importing the images into FLIR Tools.

Imaging and optical data

IR resolution 1024 × 768 pixels

MSX resolution 1024 × 768 pixels

Thermal sensitivity/NETD

Field of view (FOV) 28° × 21°

Minimum IR focus distance 0.4 m (1.32 ft.)

Minimum IR–visual alignment distance 0.4 m (1.32 ft.)

Focal length 36 mm (1.42 in.)

Spatial resolution (IFOV) 0.47 mrad

F-number 1.15

Image frequency 30 Hz

Focus One shot or manual

Digital zoom 1–8× continuous

Digital image enhancement Adaptive digital noise reduction

Detector type Focal plane array (FPA), uncooled microbolometer

Spectral range 7.5–14 µm

Detector pitch 17 µm

Display Built-in touch screen, 4.3 in. wide screen LCD, 800 × 480 pixels

Display type Capacitive touch screen

Auto orientation Automatic landscape or portrait

Viewfinder Built-in 800 × 480 pixels

Automatic image adjustment Continuous, histogram based

Show 5 more labels / short text on this page
General description · UltraMax Yes · Lens identification Automatic · Detector data · Image presentation
Page 132 of the Flir T1020 user manual — NOTE
Page 132 · click to enlarge
Page 132

Automatic image adjustment, type Standard or histogram based on the image content

Manual image adjustment Linear based, possible to adjust level/span/max./ min.

Image modes Thermal, thermal MSX, picture in picture, digital camera

Infrared image Full color infrared image

Visual image Full color visual image

Multi Spectral Dynamic Imaging (MSX) Thermal image with enhanced detail presentation

Picture in Picture Resizable and movable infrared area on the visual image

  • Gallery
  • Review thumbnail/full image on the camera
  • Edit measurements/palettes/image modes on the camera
  • Object temperature range
  • –40 to +150°C (–40 to +302°F)
  • 0 to +650°C (+32 to +1202°F)
  • +300 to +2000°C (+572 to +3632°F)
  • Accuracy
  • ±1°C (±1.8°F) or ±1% @ 25°C (77°F) for temperatures between 5 and 150°C (41 and 302° F), in range –40 to 150°C (–40 to 302°F)
  • ±2°C (±3.6°F) or ±2% of reading @ 25°C (77° F) for temperatures between –40 and 2000°C (–40 and 3632°F)

NOTE

For HSI use, above 30 Hz frame rate, the typical accuracy will be ±2.5°C (±4.5°F), or 2.5% of reading @ 25°C (77°F).

Area 5 + 5 areas (boxes and circles) with max./min./ average

Profile 1 line profile with max./min. temperature

Automatic hot/cold detection Auto hot or cold spotmeter markers within the area and profile

Measurement presets No measurements, Center spot, Hot spot, Cold spot, User preset 1, User preset 2

User presets The user can select and combine measurements from any number of spots/boxes/circles/profiles/ delta

Difference temperature Delta temperature between the measurement func- tions and the reference temperature

Reference temperature Manually set using the difference temperature

Atmospheric transmission correction Automatic, based on the inputs for distance, at- mospheric temperature, and relative humidity

Optics transmission correction Automatic, based on signals from internal sensors

Show 5 more labels / short text on this page
Image presentation · Image presentation modes · Measurement · Measurement analysis · Spotmeter 10
Page 133 of the Flir T1020 user manual — 26.8 FLIR T1020 28° and 45°
Page 133 · click to enlarge
Page 133

Emissivity correction Variable from 0.01 to 1.0 or selected from the ma- terials list

Reflected apparent temperature correction Automatic, based on the input of the reflected temperature

External optics/windows correction Automatic, based on the inputs of the window transmission and temperature

Measurement corrections Emissivity, reflected temperature, relative humidity, atmospheric temperature, object distance, external infrared window compensation

Colors (palettes) Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava

Color Alarm (isotherm) Above/below/interval

Measurement function alarm Audible/visual alarms (above/below) on any se- lected measurement function

Set-up commands Define user presets, Save options, Programmable button, Reset options, Set up camera, Wi-Fi, GPS & compass, Bluetooth, Language, Time & units, Camera information

Languages Arabic, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japa- nese, Korean, Norwegian, Polish, Portuguese, Russian, simplified Chinese, Swedish, traditional Chinese, Turkish

Camera software update Use PC software FLIR Tools

Image storage Standard JPEG, including digital image and meas- urement data, on a memory card

Storage media Removable media SD or SDHC card. Class 10 or better recommended

  • Image storage mode
  • Simultaneous storage of thermal and digital images in the same JPEG file
  • Option to store a digital photo as a separate JPEG file

Time lapse 15 seconds to 24 hours

  • File formats
  • Standard JPEG, measurement data included
  • CSQ, measurement data included

File formats, visual Standard JPEG, automatically associated with the corresponding thermal image

Voice 60 seconds (via Bluetooth) stored with the image

Text Add table, select between predefined templates

Show 6 more labels / short text on this page
Measurement analysis · Alarm · Set-up · Service functions · Storage of images · Image annotations
Page 134 of the Flir T1020 user manual — 26.8 FLIR T1020 28° and 45°
Page 134 · click to enlarge
Page 134

Image description Add short note (stored in the JPEG exif tag)

  • Sketch
  • Draw on the thermal/digital image or add predefined stamps
  • Separate PC software with extensive report generation

GPS Location data automatically added to every image from the built-in GPS

Compass Camera direction automatically added to every image

Video recording in camera

Radiometric IR-video recording Real-time radiometric recording (RTRR) to the memory card

Non-radiometric IR-video recording H.264 to the memory card

Visual video recording H.264 to the memory card

Radiometric IR-video streaming Real-time radiometric streaming (RTRS) via USB

  • Non-radiometric IR-video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Visual video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB

Digital camera Field of view adapts to the infrared lens

Video lamp Built-in LED light

Laser Activated by a dedicated button

Laser alignment Position is automatically displayed on the infrared image

Laser classification Class 2

Laser type Semiconductor AlGaInP diode laser, 1 mW, 635 nm (red)

Interfaces USB Micro-B, Bluetooth, Wi-Fi, HDMI

Bluetooth Communication with a headset

Wi-Fi Infrastructure (network) or AP

SD Card One card slot for removable SD memory cards

Audio Microphone headset via Bluetooth for the voice an- notation of images

Show 6 more labels / short text on this page
Image annotations · Geographic Information System · Video streaming · Digital camera · Laser pointer · Data communication interfaces
Page 135 of the Flir T1020 user manual — USB
Page 135 · click to enlarge
Page 135

USB

USB USB Micro-Bdata transfer to and from a PC, uncompressed colorized video
  • USB, standard
  • USB 2.0 High Speed
  • USB Micro-B connector
  • Video out
  • HDMI 640 × 480
  • HDMI 1280 × 720
  • DVI 640 × 480
  • DVI 800 × 600

Video, connector type HDMI type C

  • Wi-Fi
  • Standard: 802.11 b/g/n
  • Frequency range: 2412–2462 MHz
  • Max. output power: 15 dBm
Bluetooth Frequency range2402–2480 MHz, supports 2.1, 4.0, and 4.0 BLE

Battery type Rechargeable Li ion battery

Battery operating time >2.5 hours at 25°C (+68°F) and typical use

Charging system In camera (AC adapter or 12 V from a vehicle) or two-bay charger

Charging time 2.5 hours to 90% capacity, charging status indi- cated by LEDs

Charging temperature 0–45°C (32–113°F)

External power operation AC adapter 90–260 V AC, 50/60 Hz or 12 V from a vehicle (cable with a standard plug, optional)

Power management Automatic power-off functionality, user configura- ble between 5 minutes, 20 minutes, and no auto- matic shutdown

Operating temperature range –15°C to +50°C (+5°F to +122°F)

Storage temperature range –40 to +70°C (–40 to +158°F)

Humidity (operating and storage) IEC 60068-2-30 / 24 hours, 95% relative humidity, 25–40°C (77–104°F) / 2 cycles

  • EMC
  • ETSI EN 301 489-1 (radio)
  • ETSI EN 301 489-17
  • EN 61000-6-2 (Immunity)
  • EN 61000-6-3 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
  • ICES-003
  • Radio spectrum
  • ETSI EN 300 328
  • FCC Part 15.247
  • RSS-247 issue 1

Encapsulation IP 54 (IEC 60529)

Shock 25 g (IEC 60068-2-29)

Show 5 more labels / short text on this page
Video · Radio · Antenna Internal · Power system · Environmental data
Page 136 of the Flir T1020 user manual — Supplies & accessories:
Page 136 · click to enlarge
Page 136

Vibration 2 g (IEC 60068-2-6)

Ergonomics The viewfinder plus the 120° rotating optical block allow you to point the camera in multiple directions while maintaining a comfortable position

Weight 1.9 kg (4.3 lb.)

Camera size, excl. lens (L × W × H) 167.2 mm × 204.5 mm × 188.3 mm (6.6 in. × 8.0 in. × 7.4 in.)

Tripod mounting UNC ¼"-20

  • Warranty
  • 2 years parts and labor coverage on the camera
  • 5 years coverage on the battery
  • 10 years coverage on the detector – the most vital part of the whole camera

Packaging, size Cardboard box

  • List of contents
  • Infrared camera with lens
  • Battery (2 ea.)
  • Battery charger
  • Bluetooth headset
  • Calibration certificate
  • FLIR Tools+ license card
  • Hard transport case
  • HDMI-HDMI cable
  • IR lens, 45°
  • Lens cap
  • Memory card
  • Neck strap
  • Power supply, including multi-plugs
  • Printed documentation
  • USB cable, Std A to Micro-B

Packaging, weight 6.9 kg (15.2 lb.)

Packaging, size 494 × 355 × 188 mm (19.4 × 14.0 × 7.4 in.)

EAN-13 7332558011294

UPC-12 845188012175

Country of origin Sweden

Supplies & accessories:

  • T199064; IR lens f=36mm (28°) with case
  • T199066; IR lens f=21.2mm (45°) with case
  • T199077; IR lens f=83.4mm (12°) with case
  • T910814; Power supply, incl. multi plugs
  • T198126; Battery charger, incl. power supply with multi plugs T6xx
  • T198506; Li-Ion Battery pack 3.7V 29Wh
  • T199406ACC; Battery Li-ion 3.7 V, 7.8 Ah, 29 Wh
  • T911230ACC; Memory card SDHC 4 GB
Show 6 more labels / short text on this page
Environmental data · Safety EN/UL/CSA/PSE 60950-1 · Physical data · Housing material Magnesium · Warranty information · Shipping information
Page 137 of the Flir T1020 user manual — 26.8 FLIR T1020 28° and 45°
Page 137 · click to enlarge
Page 137
  • T198509; Cigarette lighter adapter kit, 12 VDC, 1.2 m/3.9 ft.
  • T910930ACC; HDMI type C to DVI cable 1.5 m
  • T910891ACC; HDMI type C to HDMI type A cable 1.5 m
  • T198497; Large eyecup
  • T197771ACC; Bluetooth Headset
  • T911093; Tool belt
  • T198533; USB cable Std A <-> Micro B
  • T198586; FLIR Reporter Professional (license only)
  • T198584; FLIR Tools
  • T198583; FLIR Tools+ (download card incl. license key)
  • DSW-10000; FLIR IR Camera Player
  • APP-10002; FLIR Tools Mobile (Android Application)
  • APP-10003; FLIR Tools Mobile (iPad/iPhone Application)
  • APP-10004; FLIR Tools (MacOS Application)
  • T199233; FLIR Atlas SDK for .NET
  • T199234; FLIR Atlas SDK for MATLAB
Page 138 of the Flir T1020 user manual — 26.9 FLIR T1020 28°, 12°, and 45°
Page 138 · click to enlarge
Page 138

26.9 FLIR T1020 28°, 12°, and 45°

P/N72501-0106 Rev.: 36730

The FLIR T1020 is designed for the expert requiring the highest performance and the latest technology available. The camera combines excellent ergonomics and feature-rich flexibility with superior image quality at an infrared resolution of 1024 × 768 pixels.

Benefits:

  • Flexible and feature rich: A wide variety of measuring and analysis functions make the FLIR T1020 flexible for your every need. Two programmable buttons provide easy access to favorite functions.
  • Highest performance with the latest technology: The FLIR T1020 is equipped with the innovative Multi Spectral Dynamic Imaging (MSX) feature, which produces an image richer in detail than ever before. With its continuous autofocus, the FLIR T1020 is a fully automatic infrared camera.
  • Support for UltraMax: When enabling UltraMax in the camera, the resolution of images can be substantially enhanced when importing the images into FLIR Tools.

Imaging and optical data

IR resolution 1024 × 768 pixels

MSX resolution 1024 × 768 pixels

Thermal sensitivity/NETD

Field of view (FOV) 28° × 21°

Minimum IR focus distance 0.4 m (1.32 ft.)

Minimum IR–visual alignment distance 0.4 m (1.32 ft.)

Focal length 36 mm (1.42 in.)

Spatial resolution (IFOV) 0.47 mrad

F-number 1.15

Image frequency 30 Hz

Focus One shot or manual

Digital zoom 1–8× continuous

Digital image enhancement Adaptive digital noise reduction

Detector type Focal plane array (FPA), uncooled microbolometer

Spectral range 7.5–14 µm

Detector pitch 17 µm

Display Built-in touch screen, 4.3 in. wide screen LCD, 800 × 480 pixels

Display type Capacitive touch screen

Auto orientation Automatic landscape or portrait

Viewfinder Built-in 800 × 480 pixels

Automatic image adjustment Continuous, histogram based

Show 5 more labels / short text on this page
General description · UltraMax Yes · Lens identification Automatic · Detector data · Image presentation
Page 139 of the Flir T1020 user manual — NOTE
Page 139 · click to enlarge
Page 139

Automatic image adjustment, type Standard or histogram based on the image content

Manual image adjustment Linear based, possible to adjust level/span/max./ min.

Image modes Thermal, thermal MSX, picture in picture, digital camera

Infrared image Full color infrared image

Visual image Full color visual image

Multi Spectral Dynamic Imaging (MSX) Thermal image with enhanced detail presentation

Picture in Picture Resizable and movable infrared area on the visual image

  • Gallery
  • Review thumbnail/full image on the camera
  • Edit measurements/palettes/image modes on the camera
  • Object temperature range
  • –40 to +150°C (–40 to +302°F)
  • 0 to +650°C (+32 to +1202°F)
  • +300 to +2000°C (+572 to +3632°F)
  • Accuracy
  • ±1°C (±1.8°F) or ±1% @ 25°C (77°F) for temperatures between 5 and 150°C (41 and 302° F), in range –40 to 150°C (–40 to 302°F)
  • ±2°C (±3.6°F) or ±2% of reading @ 25°C (77° F) for temperatures between –40 and 2000°C (–40 and 3632°F)

NOTE

For HSI use, above 30 Hz frame rate, the typical accuracy will be ±2.5°C (±4.5°F), or 2.5% of reading @ 25°C (77°F).

Area 5 + 5 areas (boxes and circles) with max./min./ average

Profile 1 line profile with max./min. temperature

Automatic hot/cold detection Auto hot or cold spotmeter markers within the area and profile

Measurement presets No measurements, Center spot, Hot spot, Cold spot, User preset 1, User preset 2

User presets The user can select and combine measurements from any number of spots/boxes/circles/profiles/ delta

Difference temperature Delta temperature between the measurement func- tions and the reference temperature

Reference temperature Manually set using the difference temperature

Atmospheric transmission correction Automatic, based on the inputs for distance, at- mospheric temperature, and relative humidity

Optics transmission correction Automatic, based on signals from internal sensors

Show 5 more labels / short text on this page
Image presentation · Image presentation modes · Measurement · Measurement analysis · Spotmeter 10
Page 140 of the Flir T1020 user manual — 26.9 FLIR T1020 28°, 12°, and 45°
Page 140 · click to enlarge
Page 140

Emissivity correction Variable from 0.01 to 1.0 or selected from the ma- terials list

Reflected apparent temperature correction Automatic, based on the input of the reflected temperature

External optics/windows correction Automatic, based on the inputs of the window transmission and temperature

Measurement corrections Emissivity, reflected temperature, relative humidity, atmospheric temperature, object distance, external infrared window compensation

Colors (palettes) Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava

Color Alarm (isotherm) Above/below/interval

Measurement function alarm Audible/visual alarms (above/below) on any se- lected measurement function

Set-up commands Define user presets, Save options, Programmable button, Reset options, Set up camera, Wi-Fi, GPS & compass, Bluetooth, Language, Time & units, Camera information

Languages Arabic, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japa- nese, Korean, Norwegian, Polish, Portuguese, Russian, simplified Chinese, Swedish, traditional Chinese, Turkish

Camera software update Use PC software FLIR Tools

Image storage Standard JPEG, including digital image and meas- urement data, on a memory card

Storage media Removable media SD or SDHC card. Class 10 or better recommended

  • Image storage mode
  • Simultaneous storage of thermal and digital images in the same JPEG file
  • Option to store a digital photo as a separate JPEG file

Time lapse 15 seconds to 24 hours

  • File formats
  • Standard JPEG, measurement data included
  • CSQ, measurement data included

File formats, visual Standard JPEG, automatically associated with the corresponding thermal image

Voice 60 seconds (via Bluetooth) stored with the image

Text Add table, select between predefined templates

Show 6 more labels / short text on this page
Measurement analysis · Alarm · Set-up · Service functions · Storage of images · Image annotations
Page 141 of the Flir T1020 user manual — 26.9 FLIR T1020 28°, 12°, and 45°
Page 141 · click to enlarge
Page 141

Image description Add short note (stored in the JPEG exif tag)

  • Sketch
  • Draw on the thermal/digital image or add predefined stamps
  • Separate PC software with extensive report generation

GPS Location data automatically added to every image from the built-in GPS

Compass Camera direction automatically added to every image

Video recording in camera

Radiometric IR-video recording Real-time radiometric recording (RTRR) to the memory card

Non-radiometric IR-video recording H.264 to the memory card

Visual video recording H.264 to the memory card

Radiometric IR-video streaming Real-time radiometric streaming (RTRS) via USB

  • Non-radiometric IR-video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Visual video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB

Digital camera Field of view adapts to the infrared lens

Video lamp Built-in LED light

Laser Activated by a dedicated button

Laser alignment Position is automatically displayed on the infrared image

Laser classification Class 2

Laser type Semiconductor AlGaInP diode laser, 1 mW, 635 nm (red)

Interfaces USB Micro-B, Bluetooth, Wi-Fi, HDMI

Bluetooth Communication with a headset

Wi-Fi Infrastructure (network) or AP

SD Card One card slot for removable SD memory cards

Audio Microphone headset via Bluetooth for the voice an- notation of images

Show 6 more labels / short text on this page
Image annotations · Geographic Information System · Video streaming · Digital camera · Laser pointer · Data communication interfaces
Page 142 of the Flir T1020 user manual — USB
Page 142 · click to enlarge
Page 142

USB

USB USB Micro-Bdata transfer to and from a PC, uncompressed colorized video
  • USB, standard
  • USB 2.0 High Speed
  • USB Micro-B connector
  • Video out
  • HDMI 640 × 480
  • HDMI 1280 × 720
  • DVI 640 × 480
  • DVI 800 × 600

Video, connector type HDMI type C

  • Wi-Fi
  • Standard: 802.11 b/g/n
  • Frequency range: 2412–2462 MHz
  • Max. output power: 15 dBm
Bluetooth Frequency range2402–2480 MHz, supports 2.1, 4.0, and 4.0 BLE

Battery type Rechargeable Li ion battery

Battery operating time >2.5 hours at 25°C (+68°F) and typical use

Charging system In camera (AC adapter or 12 V from a vehicle) or two-bay charger

Charging time 2.5 hours to 90% capacity, charging status indi- cated by LEDs

Charging temperature 0–45°C (32–113°F)

External power operation AC adapter 90–260 V AC, 50/60 Hz or 12 V from a vehicle (cable with a standard plug, optional)

Power management Automatic power-off functionality, user configura- ble between 5 minutes, 20 minutes, and no auto- matic shutdown

Operating temperature range –15°C to +50°C (+5°F to +122°F)

Storage temperature range –40 to +70°C (–40 to +158°F)

Humidity (operating and storage) IEC 60068-2-30 / 24 hours, 95% relative humidity, 25–40°C (77–104°F) / 2 cycles

  • EMC
  • ETSI EN 301 489-1 (radio)
  • ETSI EN 301 489-17
  • EN 61000-6-2 (Immunity)
  • EN 61000-6-3 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
  • ICES-003
  • Radio spectrum
  • ETSI EN 300 328
  • FCC Part 15.247
  • RSS-247 issue 1

Encapsulation IP 54 (IEC 60529)

Shock 25 g (IEC 60068-2-29)

Show 5 more labels / short text on this page
Video · Radio · Antenna Internal · Power system · Environmental data
Page 143 of the Flir T1020 user manual — Supplies & accessories:
Page 143 · click to enlarge
Page 143

Vibration 2 g (IEC 60068-2-6)

Ergonomics The viewfinder plus the 120° rotating optical block allow you to point the camera in multiple directions while maintaining a comfortable position

Weight 1.9 kg (4.3 lb.)

Camera size, excl. lens (L × W × H) 167.2 mm × 204.5 mm × 188.3 mm (6.6 in. × 8.0 in. × 7.4 in.)

Tripod mounting UNC ¼"-20

  • Warranty
  • 2 years parts and labor coverage on the camera
  • 5 years coverage on the battery
  • 10 years coverage on the detector – the most vital part of the whole camera

Packaging, type Cardboard box

  • List of contents
  • Infrared camera with lens
  • Battery (2 ea.)
  • Battery charger
  • Bluetooth headset
  • Calibration certificate
  • FLIR Tools+ license card
  • Hard transport case
  • HDMI-HDMI cable
  • IR lens, 12°
  • IR lens, 45°
  • Lens cap
  • Memory card
  • Neck strap
  • Power supply, including multi-plugs
  • Printed documentation
  • USB cable, Std A to Micro-B

Packaging, weight 8.2 kg (18.0 lb.)

Packaging, size 494 × 355 × 188 mm (19.4 × 14.0 × 7.4 in.)

EAN-13 7332558011300

UPC-12 845188012182

Country of origin Sweden

Supplies & accessories:

  • T199064; IR lens f=36mm (28°) with case
  • T199066; IR lens f=21.2mm (45°) with case
  • T199077; IR lens f=83.4mm (12°) with case
  • T910814; Power supply, incl. multi plugs
  • T198126; Battery charger, incl. power supply with multi plugs T6xx
  • T198506; Li-Ion Battery pack 3.7V 29Wh
  • T199406ACC; Battery Li-ion 3.7 V, 7.8 Ah, 29 Wh
Show 6 more labels / short text on this page
Environmental data · Safety EN/UL/CSA/PSE 60950-1 · Physical data · Housing material Magnesium · Warranty information · Shipping information
Page 144 of the Flir T1020 user manual — 26.9 FLIR T1020 28°, 12°, and 45°
Page 144 · click to enlarge
Page 144
  • T911230ACC; Memory card SDHC 4 GB
  • T198509; Cigarette lighter adapter kit, 12 VDC, 1.2 m/3.9 ft.
  • T910930ACC; HDMI type C to DVI cable 1.5 m
  • T910891ACC; HDMI type C to HDMI type A cable 1.5 m
  • T198497; Large eyecup
  • T197771ACC; Bluetooth Headset
  • T911093; Tool belt
  • T198533; USB cable Std A <-> Micro B
  • T198586; FLIR Reporter Professional (license only)
  • T198584; FLIR Tools
  • T198583; FLIR Tools+ (download card incl. license key)
  • DSW-10000; FLIR IR Camera Player
  • APP-10002; FLIR Tools Mobile (Android Application)
  • APP-10003; FLIR Tools Mobile (iPad/iPhone Application)
  • APP-10004; FLIR Tools (MacOS Application)
  • T199233; FLIR Atlas SDK for .NET
  • T199234; FLIR Atlas SDK for MATLAB
Page 145 of the Flir T1020 user manual — 26.10 FLIR T1030sc 12°
Page 145 · click to enlarge
Page 145

26.10 FLIR T1030sc 12°

P/N72501-0201 Rev.: 36736

The FLIR T1030sc is designed for the expert requiring the highest performance and the latest technology available. The camera combines excellent ergonomics and feature-rich flexibility with superior image quality at an infrared resolution of 1024 × 768 pixels. High accuracy and sensitivity together with radio- metric recording and streaming options make the FLIR T1030sc well suited for advanced research and development.

Benefits:

  • Tailor made for research and development: The FLIR T1030sc has high accuracy and high sensitivity, to accurately measure the smallest temperature differences. With real-time radiometric recording, it is possible to capture fast events on the camera’s SD card for further analysis by the supplied analysis software.
  • Flexible and feature rich: A wide variety of measuring and analysis functions make the FLIR T1030sc flexible for your every need. Two programmable buttons provide easy access to favorite functions.
  • Highest performance with the latest technology: The FLIR T1030sc is equipped with the innovative Multi Spectral Dynamic Imaging (MSX) feature, which produces an image richer in detail than ever before. With its continuous autofocus, the FLIR T1030sc is a fully automatic infrared camera.
  • Support for UltraMax: When enabling UltraMax in the camera, the resolution of images can be substantially enhanced when importing the images into FLIR Tools.

Imaging and optical data

IR resolution 1024 × 768 pixels

MSX resolution 1024 × 768 pixels

Thermal sensitivity/NETD

Field of view (FOV) 12° × 9°

Minimum IR focus distance 1.3 m (4.26 ft.)

Minimum IR–visual alignment distance 1.3 m (4.26 ft.)

Focal length 83.4 mm (3.28 in.)

Spatial resolution (IFOV) 0.20 mrad

F-number 1.2

Image frequency 30 Hz

Focus One shot or manual

Digital zoom 1–8× continuous

Digital image enhancement Adaptive digital noise reduction

Detector type Focal plane array (FPA), uncooled microbolometer

Spectral range 7.5–14 µm

Detector pitch 17 µm

Time constant < 10 ms

Display Built-in touch screen, 4.3 in. wide screen LCD, 800 × 480 pixels

Display type Capacitive touch screen

Show 5 more labels / short text on this page
General description · UltraMax Yes · Lens identification Automatic · Detector data · Image presentation
Page 146 of the Flir T1020 user manual — NOTE
Page 146 · click to enlarge
Page 146

Auto orientation Automatic landscape or portrait

Viewfinder Built-in 800 × 480 pixels

Automatic image adjustment Continuous, histogram based

Automatic image adjustment, type Standard or histogram based on the image content

Manual image adjustment Linear based, possible to adjust level/span/max./ min.

Image modes Thermal, thermal MSX, picture in picture, digital camera

Infrared image Full color infrared image

Visual image Full color visual image

Multi Spectral Dynamic Imaging (MSX) Thermal image with enhanced detail presentation

Picture in Picture Resizable and movable infrared area on the visual image

  • Gallery
  • Review thumbnail/full image on the camera
  • Edit measurements/palettes/image modes on the camera
  • Object temperature range
  • –40 to +150°C (–40 to +302°F)
  • 0 to +650°C (+32 to +1202°F)
  • +300 to +2000°C (+572 to +3632°F)
  • Accuracy
  • ±1°C (±1.8°F) or ±1% @ 25°C (77°F) for temperatures between 5 and 150°C (41 and 302° F), in range –40 to 150°C (–40 to 302°F)
  • ±2°C (±3.6°F) or ±2% of reading @ 25°C (77° F) for temperatures between –40 and 2000°C (–40 and 3632°F)

NOTE

For HSI (high-speed interface) use, above 30 Hz frame rate, the typical accuracy will be ±2.5° C (±4.5°F), or 2.5% of reading @ 25°C (77°F).

Area 5 + 5 areas (boxes and circles) with max./min./ average

Profile 1 line profile with max./min. temperature

Automatic hot/cold detection Auto hot or cold spotmeter markers within the area and profile

Measurement presets No measurements, Center spot, Hot spot, Cold spot, User preset 1, User preset 2

User presets The user can select and combine measurements from any number of spots/boxes/circles/profiles/ delta

Difference temperature Delta temperature between the measurement func- tions and the reference temperature

Show 5 more labels / short text on this page
Image presentation · Image presentation modes · Measurement · Measurement analysis · Spotmeter 10
Page 147 of the Flir T1020 user manual — 26.10 FLIR T1030sc 12°
Page 147 · click to enlarge
Page 147

Reference temperature Manually set using the difference temperature

Atmospheric transmission correction Automatic, based on the inputs for distance, at- mospheric temperature, and relative humidity

Optics transmission correction Automatic, based on signals from internal sensors

Emissivity correction Variable from 0.01 to 1.0 or selected from the ma- terials list

Reflected apparent temperature correction Automatic, based on the input of the reflected temperature

External optics/windows correction Automatic, based on the inputs of the window transmission and temperature

Measurement corrections Emissivity, reflected temperature, relative humidity, atmospheric temperature, object distance, external infrared window compensation

Colors (palettes) Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava

Color Alarm (isotherm) Above/below/interval

Measurement function alarm Audible/visual alarms (above/below) on any se- lected measurement function

Set-up commands Define user presets, Save options, Programmable button, Reset options, Set up camera, Wi-Fi, GPS & compass, Bluetooth, Language, Time & units, Camera information

Languages Arabic, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japa- nese, Korean, Norwegian, Polish, Portuguese, Russian, simplified Chinese, Swedish, traditional Chinese, Turkish

Camera software update Use PC software FLIR Tools

Image storage Standard JPEG, including digital image and meas- urement data, on a memory card

Storage media Removable media SD or SDHC card. Class 10 or better recommended

  • Image storage mode
  • Simultaneous storage of thermal and digital images in the same JPEG file
  • Option to store a digital photo as a separate JPEG file

Time lapse 15 seconds to 24 hours

  • File formats
  • Standard JPEG, measurement data included
  • CSQ, measurement data included

File formats, visual Standard JPEG, automatically associated with the corresponding thermal image

Show 5 more labels / short text on this page
Measurement analysis · Alarm · Set-up · Service functions · Storage of images
Page 148 of the Flir T1020 user manual — 26.10 FLIR T1030sc 12°
Page 148 · click to enlarge
Page 148

Voice 60 seconds (via Bluetooth) stored with the image

Text Add table, select between predefined templates

Image description Add short note (stored in the JPEG exif tag)

  • Sketch
  • Draw on the thermal/digital image or add predefined stamps
  • Separate PC software with extensive report generation

GPS Location data automatically added to every image from the built-in GPS

Compass Camera direction automatically added to every image

Video recording in camera

Radiometric IR-video recording Real-time radiometric recording (RTRR) to the memory card

Non-radiometric IR-video recording H.264 to the memory card

Visual video recording H.264 to the memory card

  • Radiometric IR-video streaming
  • Full dynamic un-compressed 120 Hz 16-bit full frame (2 Gbit) to a PC using an HSI box
  • Real-time radiometric streaming 30 Hz (RTRS) via USB
  • Non-radiometric IR-video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Visual video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Windowing
  • 30 Hz: 1024 × 768 (full image height)
  • Based on 30 Hz: 120 Hz windowing 1024 × 192 (¼ of full image height), for range –40 to +150°C (–40 to +302°F)
  • 120 Hz: 1024 × 768 (full image height)
  • Based on 120 Hz: 240 Hz windowing 1024 × 384 (½ of full image height), for range 0 to +650°C (+32 to +1202°F) and range +300 to +2000°C (+572 to +3632°F)

Digital camera Field of view adapts to the infrared lens

Video lamp Built-in LED light

Laser Activated by a dedicated button

Laser alignment Position is automatically displayed on the infrared image

Laser classification Class 2

Laser type Semiconductor AlGaInP diode laser, 1 mW, 635 nm (red)

Show 5 more labels / short text on this page
Image annotations · Geographic Information System · Video streaming · Digital camera · Laser pointer
Page 149 of the Flir T1020 user manual — USB
Page 149 · click to enlarge
Page 149

Interfaces USB Micro-B, Bluetooth, Wi-Fi, HDMI, USB3 Vi- sion via HSI box

Bluetooth Communication with a headset

Wi-Fi Infrastructure (network) or AP

SD Card One card slot for removable SD memory cards

Audio Microphone headset via Bluetooth for the voice an- notation of images

USB

USB USB Micro-Bdata transfer to and from a PC, uncompressed colorized video
  • USB, standard
  • USB 2.0 High Speed
  • USB Micro-B connector
  • USB3 Vision via HSI box
  • Video out
  • HDMI 640 × 480
  • HDMI 1280 × 720
  • DVI 640 × 480
  • DVI 800 × 600

Video, connector type HDMI type C

  • Wi-Fi
  • Standard: 802.11 b/g/n
  • Frequency range: 2412–2462 MHz
  • Max. output power: 15 dBm
Bluetooth Frequency range2402–2480 MHz, supports 2.1, 4.0, and 4.0 BLE

Battery type Rechargeable Li ion battery

Battery operating time >2.5 hours at 25°C (+68°F) and typical use

Charging system In camera (AC adapter or 12 V from a vehicle) or two-bay charger

Charging time 2.5 hours to 90% capacity, charging status indi- cated by LEDs

Charging temperature 0–45°C (32–113°F)

External power operation AC adapter 90–260 V AC, 50/60 Hz or 12 V from a vehicle (cable with a standard plug, optional)

Power management Automatic power-off functionality, user configura- ble between 5 minutes, 20 minutes, and no auto- matic shutdown

Operating temperature range –15°C to +50°C (+5°F to +122°F)

Storage temperature range –40 to +70°C (–40 to +158°F)

Humidity (operating and storage) IEC 60068-2-30 / 24 hours, 95% relative humidity, 25–40°C (77–104°F) / 2 cycles

Show 6 more labels / short text on this page
Data communication interfaces · Video · Radio · Antenna Internal · Power system · Environmental data
Page 150 of the Flir T1020 user manual — EAN-13 7332558010303
Page 150 · click to enlarge
Page 150
  • EMC
  • ETSI EN 301 489-1 (radio)
  • ETSI EN 301 489-17
  • EN 61000-6-2 (Immunity)
  • EN 61000-6-3 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
  • ICES-003
  • Radio spectrum
  • ETSI EN 300 328
  • FCC Part 15.247
  • RSS-247 issue 1

Encapsulation IP 54 (IEC 60529)

Shock 25 g (IEC 60068-2-29)

Vibration 2 g (IEC 60068-2-6)

Ergonomics The viewfinder plus the 120° rotating optical block allow you to point the camera in multiple directions while maintaining a comfortable position

Weight 2.1 kg (4.6 lb.)

Camera size, excl. lens (L × W × H) 167.2 mm × 204.5 mm × 188.3 mm (6.6 in. × 8.0 in. × 7.4 in.)

Tripod mounting UNC ¼"-20

  • Warranty
  • 2 years parts and labor coverage on the camera
  • 5 years coverage on the battery
  • 10 years coverage on the detector – the most vital part of the whole camera
  • List of contents
  • Infrared camera with lens
  • Battery (2 ea.)
  • Battery charger
  • Bluetooth headset
  • Calibration certificate
  • FLIR Tools+ license card
  • FLIR T10xx SC kit (in separate hard transport case):
  • High-speed interface
  • USB cable (USB 3), 3 m (10 ft.)
  • Digital I/O connector
  • FLIR ResearchIR Max license card
  • Printed documentation
  • Hard transport case
  • HDMI-HDMI cable
  • Lens cap
  • Memory card
  • Neck strap
  • Power supply, including multi-plugs
  • Printed documentation
  • USB cable, Std A to Micro-B

EAN-13 7332558010303

Show 6 more labels / short text on this page
Environmental data · Safety EN/UL/CSA/PSE 60950-1 · Physical data · Housing material Magnesium · Warranty information · Shipping information
Page 151 of the Flir T1020 user manual — Supplies & accessories
Page 151 · click to enlarge
Page 151

UPC-12 845188010942

Country of origin Sweden

Supplies & accessories

  • T199064; IR lens f=36mm (28°) with case
  • T199065; Close-up lens 3x (51 micron) with case
  • T199066; IR lens f=21.2mm (45°) with case
  • T199077; IR lens f=83.4mm (12°) with case
  • T910814; Power supply, incl. multi plugs
  • T198126; Battery charger, incl. power supply with multi plugs T6xx
  • T198506; Li-Ion Battery pack 3.7V 29Wh
  • T199406ACC; Battery Li-ion 3.7 V, 7.8 Ah, 29 Wh
  • T911230ACC; Memory card SDHC 4 GB
  • T198509; Cigarette lighter adapter kit, 12 VDC, 1.2 m/3.9 ft.
  • T910930ACC; HDMI type C to DVI cable 1.5 m
  • T910891ACC; HDMI type C to HDMI type A cable 1.5 m
  • 72500-0002; FLIR T10xx SC kit
  • T198497; Large eyecup
  • T197771ACC; Bluetooth Headset
  • T911093; Tool belt
  • T198533; USB cable Std A <-> Micro B
  • T198586; FLIR Reporter Professional (license only)
  • T198584; FLIR Tools
  • T198583; FLIR Tools+ (download card incl. license key)
  • DSW-10000; FLIR IR Camera Player
  • APP-10002; FLIR Tools Mobile (Android Application)
  • APP-10003; FLIR Tools Mobile (iPad/iPhone Application)
  • APP-10004; FLIR Tools (MacOS Application)
  • T198697; FLIR ResearchIR Max + HSDR 4 (hardware sec. dev.)
  • T199014; FLIR ResearchIR Max + HSDR 4 (printed license key)
  • T199044; FLIR ResearchIR Max + HSDR 4 Upgrade (printed license key)
  • T198696; FLIR ResearchIR Max 4 (hardware sec. dev.)
  • T199013; FLIR ResearchIR Max 4 (printed license key)
  • T199043; FLIR ResearchIR Max 4 Upgrade (printed license key)
  • T198731; FLIR ResearchIR Standard 4 (hardware sec. dev.)
  • T199012; FLIR ResearchIR Standard 4 (printed license key)
  • T199042; FLIR ResearchIR Standard 4 Upgrade (printed license key)
  • T199233; FLIR Atlas SDK for .NET
  • T199234; FLIR Atlas SDK for MATLAB

Shipping information

Page 152 of the Flir T1020 user manual — 26.11 FLIR T1030sc 28°
Page 152 · click to enlarge
Page 152

26.11 FLIR T1030sc 28°

P/N72501-0202 Rev.: 36737

The FLIR T1030sc is designed for the expert requiring the highest performance and the latest technology available. The camera combines excellent ergonomics and feature-rich flexibility with superior image quality at an infrared resolution of 1024 × 768 pixels. High accuracy and sensitivity together with radio- metric recording and streaming options make the FLIR T1030sc well suited for advanced research and development.

Benefits:

  • Tailor made for research and development: The FLIR T1030sc has high accuracy and high sensitivity, to accurately measure the smallest temperature differences. With real-time radiometric recording, it is possible to capture fast events on the camera’s SD card for further analysis by the supplied analysis software.
  • Flexible and feature rich: A wide variety of measuring and analysis functions make the FLIR T1030sc flexible for your every need. Two programmable buttons provide easy access to favorite functions.
  • Highest performance with the latest technology: The FLIR T1030sc is equipped with the innovative Multi Spectral Dynamic Imaging (MSX) feature, which produces an image richer in detail than ever before. With its continuous autofocus, the FLIR T1030sc is a fully automatic infrared camera.
  • Support for UltraMax: When enabling UltraMax in the camera, the resolution of images can be substantially enhanced when importing the images into FLIR Tools.

Imaging and optical data

IR resolution 1024 × 768 pixels

MSX resolution 1024 × 768 pixels

Thermal sensitivity/NETD

Field of view (FOV) 28° × 21°

Minimum IR focus distance 0.4 m (1.32 ft.)

Minimum IR–visual alignment distance 0.4 m (1.32 ft.)

Focal length 36 mm (1.42 in.)

Spatial resolution (IFOV) 0.47 mrad

F-number 1.15

Image frequency 30 Hz

Focus One shot or manual

Digital zoom 1–8× continuous

Digital image enhancement Adaptive digital noise reduction

Detector type Focal plane array (FPA), uncooled microbolometer

Spectral range 7.5–14 µm

Detector pitch 17 µm

Time constant < 10 ms

Display Built-in touch screen, 4.3 in. wide screen LCD, 800 × 480 pixels

Display type Capacitive touch screen

Show 5 more labels / short text on this page
General description · UltraMax Yes · Lens identification Automatic · Detector data · Image presentation
Page 153 of the Flir T1020 user manual — NOTE
Page 153 · click to enlarge
Page 153

Auto orientation Automatic landscape or portrait

Viewfinder Built-in 800 × 480 pixels

Automatic image adjustment Continuous, histogram based

Automatic image adjustment, type Standard or histogram based on the image content

Manual image adjustment Linear based, possible to adjust level/span/max./ min.

Image modes Thermal, thermal MSX, picture in picture, digital camera

Infrared image Full color infrared image

Visual image Full color visual image

Multi Spectral Dynamic Imaging (MSX) Thermal image with enhanced detail presentation

Picture in Picture Resizable and movable infrared area on the visual image

  • Gallery
  • Review thumbnail/full image on the camera
  • Edit measurements/palettes/image modes on the camera
  • Object temperature range
  • –40 to +150°C (–40 to +302°F)
  • 0 to +650°C (+32 to +1202°F)
  • +300 to +2000°C (+572 to +3632°F)
  • Accuracy
  • ±1°C (±1.8°F) or ±1% @ 25°C (77°F) for temperatures between 5 and 150°C (41 and 302° F), in range –40 to 150°C (–40 to 302°F)
  • ±2°C (±3.6°F) or ±2% of reading @ 25°C (77° F) for temperatures between –40 and 2000°C (–40 and 3632°F)

NOTE

For HSI (high-speed interface) use, above 30 Hz frame rate, the typical accuracy will be ±2.5° C (±4.5°F), or 2.5% of reading @ 25°C (77°F).

Area 5 + 5 areas (boxes and circles) with max./min./ average

Profile 1 line profile with max./min. temperature

Automatic hot/cold detection Auto hot or cold spotmeter markers within the area and profile

Measurement presets No measurements, Center spot, Hot spot, Cold spot, User preset 1, User preset 2

User presets The user can select and combine measurements from any number of spots/boxes/circles/profiles/ delta

Difference temperature Delta temperature between the measurement func- tions and the reference temperature

Show 5 more labels / short text on this page
Image presentation · Image presentation modes · Measurement · Measurement analysis · Spotmeter 10
Page 154 of the Flir T1020 user manual — 26.11 FLIR T1030sc 28°
Page 154 · click to enlarge
Page 154

Reference temperature Manually set using the difference temperature

Atmospheric transmission correction Automatic, based on the inputs for distance, at- mospheric temperature, and relative humidity

Optics transmission correction Automatic, based on signals from internal sensors

Emissivity correction Variable from 0.01 to 1.0 or selected from the ma- terials list

Reflected apparent temperature correction Automatic, based on the input of the reflected temperature

External optics/windows correction Automatic, based on the inputs of the window transmission and temperature

Measurement corrections Emissivity, reflected temperature, relative humidity, atmospheric temperature, object distance, external infrared window compensation

Colors (palettes) Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava

Color Alarm (isotherm) Above/below/interval

Measurement function alarm Audible/visual alarms (above/below) on any se- lected measurement function

Set-up commands Define user presets, Save options, Programmable button, Reset options, Set up camera, Wi-Fi, GPS & compass, Bluetooth, Language, Time & units, Camera information

Languages Arabic, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japa- nese, Korean, Norwegian, Polish, Portuguese, Russian, simplified Chinese, Swedish, traditional Chinese, Turkish

Camera software update Use PC software FLIR Tools

Image storage Standard JPEG, including digital image and meas- urement data, on a memory card

Storage media Removable media SD or SDHC card. Class 10 or better recommended

  • Image storage mode
  • Simultaneous storage of thermal and digital images in the same JPEG file
  • Option to store a digital photo as a separate JPEG file

Time lapse 15 seconds to 24 hours

  • File formats
  • Standard JPEG, measurement data included
  • CSQ, measurement data included

File formats, visual Standard JPEG, automatically associated with the corresponding thermal image

Show 5 more labels / short text on this page
Measurement analysis · Alarm · Set-up · Service functions · Storage of images
Page 155 of the Flir T1020 user manual — 26.11 FLIR T1030sc 28°
Page 155 · click to enlarge
Page 155

Voice 60 seconds (via Bluetooth) stored with the image

Text Add table, select between predefined templates

Image description Add short note (stored in the JPEG exif tag)

  • Sketch
  • Draw on the thermal/digital image or add predefined stamps
  • Separate PC software with extensive report generation

GPS Location data automatically added to every image from the built-in GPS

Compass Camera direction automatically added to every image

Video recording in camera

Radiometric IR-video recording Real-time radiometric recording (RTRR) to the memory card

Non-radiometric IR-video recording H.264 to the memory card

Visual video recording H.264 to the memory card

  • Radiometric IR-video streaming
  • Full dynamic un-compressed 120 Hz 16-bit full frame (2 Gbit) to a PC using an HSI box
  • Real-time radiometric streaming 30 Hz (RTRS) via USB
  • Non-radiometric IR-video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Visual video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Windowing
  • 30 Hz: 1024 × 768 (full image height)
  • Based on 30 Hz: 120 Hz windowing 1024 × 192 (¼ of full image height), for range –40 to +150°C (–40 to +302°F)
  • 120 Hz: 1024 × 768 (full image height)
  • Based on 120 Hz: 240 Hz windowing 1024 × 384 (½ of full image height), for range 0 to +650°C (+32 to +1202°F) and range +300 to +2000°C (+572 to +3632°F)

Digital camera Field of view adapts to the infrared lens

Video lamp Built-in LED light

Laser Activated by a dedicated button

Laser alignment Position is automatically displayed on the infrared image

Laser classification Class 2

Laser type Semiconductor AlGaInP diode laser, 1 mW, 635 nm (red)

Show 5 more labels / short text on this page
Image annotations · Geographic Information System · Video streaming · Digital camera · Laser pointer
Page 156 of the Flir T1020 user manual — USB
Page 156 · click to enlarge
Page 156

Interfaces USB Micro-B, Bluetooth, Wi-Fi, HDMI, USB3 Vi- sion via HSI box

Bluetooth Communication with a headset

Wi-Fi Infrastructure (network) or AP

SD Card One card slot for removable SD memory cards

Audio Microphone headset via Bluetooth for the voice an- notation of images

USB

USB USB Micro-Bdata transfer to and from a PC, uncompressed colorized video
  • USB, standard
  • USB 2.0 High Speed
  • USB Micro-B connector
  • USB3 Vision via HSI box
  • Video out
  • HDMI 640 × 480
  • HDMI 1280 × 720
  • DVI 640 × 480
  • DVI 800 × 600

Video, connector type HDMI type C

  • Wi-Fi
  • Standard: 802.11 b/g/n
  • Frequency range: 2412–2462 MHz
  • Max. output power: 15 dBm
Bluetooth Frequency range2402–2480 MHz, supports 2.1, 4.0, and 4.0 BLE

Battery type Rechargeable Li ion battery

Battery operating time >2.5 hours at 25°C (+68°F) and typical use

Charging system In camera (AC adapter or 12 V from a vehicle) or two-bay charger

Charging time 2.5 hours to 90% capacity, charging status indi- cated by LEDs

Charging temperature 0–45°C (32–113°F)

External power operation AC adapter 90–260 V AC, 50/60 Hz or 12 V from a vehicle (cable with a standard plug, optional)

Power management Automatic power-off functionality, user configura- ble between 5 minutes, 20 minutes, and no auto- matic shutdown

Operating temperature range –15°C to +50°C (+5°F to +122°F)

Storage temperature range –40 to +70°C (–40 to +158°F)

Humidity (operating and storage) IEC 60068-2-30 / 24 hours, 95% relative humidity, 25–40°C (77–104°F) / 2 cycles

Show 6 more labels / short text on this page
Data communication interfaces · Video · Radio · Antenna Internal · Power system · Environmental data
Page 157 of the Flir T1020 user manual — EAN-13 7332558010310
Page 157 · click to enlarge
Page 157
  • EMC
  • ETSI EN 301 489-1 (radio)
  • ETSI EN 301 489-17
  • EN 61000-6-2 (Immunity)
  • EN 61000-6-3 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
  • ICES-003
  • Radio spectrum
  • ETSI EN 300 328
  • FCC Part 15.247
  • RSS-247 issue 1

Encapsulation IP 54 (IEC 60529)

Shock 25 g (IEC 60068-2-29)

Vibration 2 g (IEC 60068-2-6)

Ergonomics The viewfinder plus the 120° rotating optical block allow you to point the camera in multiple directions while maintaining a comfortable position

Weight 1.9 kg (4.3 lb.)

Camera size, excl. lens (L × W × H) 167.2 mm × 204.5 mm × 188.3 mm (6.6 in. × 8.0 in. × 7.4 in.)

Tripod mounting UNC ¼"-20

  • Warranty
  • 2 years parts and labor coverage on the camera
  • 5 years coverage on the battery
  • 10 years coverage on the detector – the most vital part of the whole camera
  • List of contents
  • Infrared camera with lens
  • Battery (2 ea.)
  • Battery charger
  • Bluetooth headset
  • Calibration certificate
  • FLIR Tools+ license card
  • FLIR T10xx SC kit (in separate hard transport case):
  • High-speed interface
  • USB cable (USB 3), 3 m (10 ft.)
  • Digital I/O connector
  • FLIR ResearchIR Max license card
  • Printed documentation
  • Hard transport case
  • HDMI-HDMI cable
  • Lens cap
  • Memory card
  • Neck strap
  • Power supply, including multi-plugs
  • Printed documentation
  • USB cable, Std A to Micro-B

EAN-13 7332558010310

Show 6 more labels / short text on this page
Environmental data · Safety EN/UL/CSA/PSE 60950-1 · Physical data · Housing material Magnesium · Warranty information · Shipping information
Page 158 of the Flir T1020 user manual — Supplies & accessories
Page 158 · click to enlarge
Page 158

UPC-12 845188010959

Country of origin Sweden

Supplies & accessories

  • T199064; IR lens f=36mm (28°) with case
  • T199065; Close-up lens 3x (51 micron) with case
  • T199066; IR lens f=21.2mm (45°) with case
  • T199077; IR lens f=83.4mm (12°) with case
  • T910814; Power supply, incl. multi plugs
  • T198126; Battery charger, incl. power supply with multi plugs T6xx
  • T198506; Li-Ion Battery pack 3.7V 29Wh
  • T199406ACC; Battery Li-ion 3.7 V, 7.8 Ah, 29 Wh
  • T911230ACC; Memory card SDHC 4 GB
  • T198509; Cigarette lighter adapter kit, 12 VDC, 1.2 m/3.9 ft.
  • T910930ACC; HDMI type C to DVI cable 1.5 m
  • T910891ACC; HDMI type C to HDMI type A cable 1.5 m
  • 72500-0002; FLIR T10xx SC kit
  • T198497; Large eyecup
  • T197771ACC; Bluetooth Headset
  • T911093; Tool belt
  • T198533; USB cable Std A <-> Micro B
  • T198586; FLIR Reporter Professional (license only)
  • T198584; FLIR Tools
  • T198583; FLIR Tools+ (download card incl. license key)
  • DSW-10000; FLIR IR Camera Player
  • APP-10002; FLIR Tools Mobile (Android Application)
  • APP-10003; FLIR Tools Mobile (iPad/iPhone Application)
  • APP-10004; FLIR Tools (MacOS Application)
  • T198697; FLIR ResearchIR Max + HSDR 4 (hardware sec. dev.)
  • T199014; FLIR ResearchIR Max + HSDR 4 (printed license key)
  • T199044; FLIR ResearchIR Max + HSDR 4 Upgrade (printed license key)
  • T198696; FLIR ResearchIR Max 4 (hardware sec. dev.)
  • T199013; FLIR ResearchIR Max 4 (printed license key)
  • T199043; FLIR ResearchIR Max 4 Upgrade (printed license key)
  • T198731; FLIR ResearchIR Standard 4 (hardware sec. dev.)
  • T199012; FLIR ResearchIR Standard 4 (printed license key)
  • T199042; FLIR ResearchIR Standard 4 Upgrade (printed license key)
  • T199233; FLIR Atlas SDK for .NET
  • T199234; FLIR Atlas SDK for MATLAB

Shipping information

Page 159 of the Flir T1020 user manual — 26.12 FLIR T1030sc 45°
Page 159 · click to enlarge
Page 159

26.12 FLIR T1030sc 45°

P/N72501-0203 Rev.: 36738

The FLIR T1030sc is designed for the expert requiring the highest performance and the latest technology available. The camera combines excellent ergonomics and feature-rich flexibility with superior image quality at an infrared resolution of 1024 × 768 pixels. High accuracy and sensitivity together with radio- metric recording and streaming options make the FLIR T1030sc well suited for advanced research and development.

Benefits:

  • Tailor made for research and development: The FLIR T1030sc has high accuracy and high sensitivity, to accurately measure the smallest temperature differences. With real-time radiometric recording, it is possible to capture fast events on the camera’s SD card for further analysis by the supplied analysis software.
  • Flexible and feature rich: A wide variety of measuring and analysis functions make the FLIR T1030sc flexible for your every need. Two programmable buttons provide easy access to favorite functions.
  • Highest performance with the latest technology: The FLIR T1030sc is equipped with the innovative Multi Spectral Dynamic Imaging (MSX) feature, which produces an image richer in detail than ever before. With its continuous autofocus, the FLIR T1030sc is a fully automatic infrared camera.
  • Support for UltraMax: When enabling UltraMax in the camera, the resolution of images can be substantially enhanced when importing the images into FLIR Tools.

Imaging and optical data

IR resolution 1024 × 768 pixels

MSX resolution 1024 × 768 pixels

Thermal sensitivity/NETD

Field of view (FOV) 45° × 34°

Minimum IR focus distance 0.2 m (0.66 ft.)

Minimum IR–visual alignment distance 0.5 m (1.64 ft.)

Focal length 21.2 mm (0.83 in.)

Spatial resolution (IFOV) 0.80 mrad

F-number 1.1

Image frequency 30 Hz

Focus One shot or manual

Digital zoom 1–8× continuous

Digital image enhancement Adaptive digital noise reduction

Detector type Focal plane array (FPA), uncooled microbolometer

Spectral range 7.5–14 µm

Detector pitch 17 µm

Time constant < 10 ms

Display Built-in touch screen, 4.3 in. wide screen LCD, 800 × 480 pixels

Display type Capacitive touch screen

Show 5 more labels / short text on this page
General description · UltraMax Yes · Lens identification Automatic · Detector data · Image presentation
Page 160 of the Flir T1020 user manual — NOTE
Page 160 · click to enlarge
Page 160

Auto orientation Automatic landscape or portrait

Viewfinder Built-in 800 × 480 pixels

Automatic image adjustment Continuous, histogram based

Automatic image adjustment, type Standard or histogram based on the image content

Manual image adjustment Linear based, possible to adjust level/span/max./ min.

Image modes Thermal, thermal MSX, picture in picture, digital camera

Infrared image Full color infrared image

Visual image Full color visual image

Multi Spectral Dynamic Imaging (MSX) Thermal image with enhanced detail presentation

Picture in Picture Resizable and movable infrared area on the visual image

  • Gallery
  • Review thumbnail/full image on the camera
  • Edit measurements/palettes/image modes on the camera
  • Object temperature range
  • –40 to +150°C (–40 to +302°F)
  • 0 to +650°C (+32 to +1202°F)
  • +300 to +2000°C (+572 to +3632°F)
  • Accuracy
  • ±1°C (±1.8°F) or ±1% @ 25°C (77°F) for temperatures between 5 and 150°C (41 and 302° F), in range –40 to 150°C (–40 to 302°F)
  • ±2°C (±3.6°F) or ±2% of reading @ 25°C (77° F) for temperatures between –40 and 2000°C (–40 and 3632°F)

NOTE

For HSI (high-speed interface) use, above 30 Hz frame rate, the typical accuracy will be ±2.5° C (±4.5°F), or 2.5% of reading @ 25°C (77°F).

Area 5 + 5 areas (boxes and circles) with max./min./ average

Profile 1 line profile with max./min. temperature

Automatic hot/cold detection Auto hot or cold spotmeter markers within the area and profile

Measurement presets No measurements, Center spot, Hot spot, Cold spot, User preset 1, User preset 2

User presets The user can select and combine measurements from any number of spots/boxes/circles/profiles/ delta

Difference temperature Delta temperature between the measurement func- tions and the reference temperature

Show 5 more labels / short text on this page
Image presentation · Image presentation modes · Measurement · Measurement analysis · Spotmeter 10
Page 161 of the Flir T1020 user manual — 26.12 FLIR T1030sc 45°
Page 161 · click to enlarge
Page 161

Reference temperature Manually set using the difference temperature

Atmospheric transmission correction Automatic, based on the inputs for distance, at- mospheric temperature, and relative humidity

Optics transmission correction Automatic, based on signals from internal sensors

Emissivity correction Variable from 0.01 to 1.0 or selected from the ma- terials list

Reflected apparent temperature correction Automatic, based on the input of the reflected temperature

External optics/windows correction Automatic, based on the inputs of the window transmission and temperature

Measurement corrections Emissivity, reflected temperature, relative humidity, atmospheric temperature, object distance, external infrared window compensation

Colors (palettes) Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava

Color Alarm (isotherm) Above/below/interval

Measurement function alarm Audible/visual alarms (above/below) on any se- lected measurement function

Set-up commands Define user presets, Save options, Programmable button, Reset options, Set up camera, Wi-Fi, GPS & compass, Bluetooth, Language, Time & units, Camera information

Languages Arabic, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japa- nese, Korean, Norwegian, Polish, Portuguese, Russian, simplified Chinese, Swedish, traditional Chinese, Turkish

Camera software update Use PC software FLIR Tools

Image storage Standard JPEG, including digital image and meas- urement data, on a memory card

Storage media Removable media SD or SDHC card. Class 10 or better recommended

  • Image storage mode
  • Simultaneous storage of thermal and digital images in the same JPEG file
  • Option to store a digital photo as a separate JPEG file

Time lapse 15 seconds to 24 hours

  • File formats
  • Standard JPEG, measurement data included
  • CSQ, measurement data included

File formats, visual Standard JPEG, automatically associated with the corresponding thermal image

Show 5 more labels / short text on this page
Measurement analysis · Alarm · Set-up · Service functions · Storage of images
Page 162 of the Flir T1020 user manual — 26.12 FLIR T1030sc 45°
Page 162 · click to enlarge
Page 162

Voice 60 seconds (via Bluetooth) stored with the image

Text Add table, select between predefined templates

Image description Add short note (stored in the JPEG exif tag)

  • Sketch
  • Draw on the thermal/digital image or add predefined stamps
  • Separate PC software with extensive report generation

GPS Location data automatically added to every image from the built-in GPS

Compass Camera direction automatically added to every image

Video recording in camera

Radiometric IR-video recording Real-time radiometric recording (RTRR) to the memory card

Non-radiometric IR-video recording H.264 to the memory card

Visual video recording H.264 to the memory card

  • Radiometric IR-video streaming
  • Full dynamic un-compressed 120 Hz 16-bit full frame (2 Gbit) to a PC using an HSI box
  • Real-time radiometric streaming 30 Hz (RTRS) via USB
  • Non-radiometric IR-video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Visual video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Windowing
  • 30 Hz: 1024 × 768 (full image height)
  • Based on 30 Hz: 120 Hz windowing 1024 × 192 (¼ of full image height), for range –40 to +150°C (–40 to +302°F)
  • 120 Hz: 1024 × 768 (full image height)
  • Based on 120 Hz: 240 Hz windowing 1024 × 384 (½ of full image height), for range 0 to +650°C (+32 to +1202°F) and range +300 to +2000°C (+572 to +3632°F)

Digital camera Field of view adapts to the infrared lens

Video lamp Built-in LED light

Laser Activated by a dedicated button

Laser alignment Position is automatically displayed on the infrared image

Laser classification Class 2

Laser type Semiconductor AlGaInP diode laser, 1 mW, 635 nm (red)

Show 5 more labels / short text on this page
Image annotations · Geographic Information System · Video streaming · Digital camera · Laser pointer
Page 163 of the Flir T1020 user manual — USB
Page 163 · click to enlarge
Page 163

Interfaces USB Micro-B, Bluetooth, Wi-Fi, HDMI, USB3 Vi- sion via HSI box

Bluetooth Communication with a headset

Wi-Fi Infrastructure (network) or AP

SD Card One card slot for removable SD memory cards

Audio Microphone headset via Bluetooth for the voice an- notation of images

USB

USB USB Micro-Bdata transfer to and from a PC, uncompressed colorized video
  • USB, standard
  • USB 2.0 High Speed
  • USB Micro-B connector
  • USB3 Vision via HSI box
  • Video out
  • HDMI 640 × 480
  • HDMI 1280 × 720
  • DVI 640 × 480
  • DVI 800 × 600

Video, connector type HDMI type C

  • Wi-Fi
  • Standard: 802.11 b/g/n
  • Frequency range: 2412–2462 MHz
  • Max. output power: 15 dBm
Bluetooth Frequency range2402–2480 MHz, supports 2.1, 4.0, and 4.0 BLE

Battery type Rechargeable Li ion battery

Battery operating time >2.5 hours at 25°C (+68°F) and typical use

Charging system In camera (AC adapter or 12 V from a vehicle) or two-bay charger

Charging time 2.5 hours to 90% capacity, charging status indi- cated by LEDs

Charging temperature 0–45°C (32–113°F)

External power operation AC adapter 90–260 V AC, 50/60 Hz or 12 V from a vehicle (cable with a standard plug, optional)

Power management Automatic power-off functionality, user configura- ble between 5 minutes, 20 minutes, and no auto- matic shutdown

Operating temperature range –15°C to +50°C (+5°F to +122°F)

Storage temperature range –40 to +70°C (–40 to +158°F)

Humidity (operating and storage) IEC 60068-2-30 / 24 hours, 95% relative humidity, 25–40°C (77–104°F) / 2 cycles

Show 6 more labels / short text on this page
Data communication interfaces · Video · Radio · Antenna Internal · Power system · Environmental data
Page 164 of the Flir T1020 user manual — EAN-13 7332558010327
Page 164 · click to enlarge
Page 164
  • EMC
  • ETSI EN 301 489-1 (radio)
  • ETSI EN 301 489-17
  • EN 61000-6-2 (Immunity)
  • EN 61000-6-3 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
  • ICES-003
  • Radio spectrum
  • ETSI EN 300 328
  • FCC Part 15.247
  • RSS-247 issue 1

Encapsulation IP 54 (IEC 60529)

Shock 25 g (IEC 60068-2-29)

Vibration 2 g (IEC 60068-2-6)

Ergonomics The viewfinder plus the 120° rotating optical block allow you to point the camera in multiple directions while maintaining a comfortable position

Weight 2.0 kg (4.3 lb.)

Camera size, excl. lens (L × W × H) 167.2 mm × 204.5 mm × 188.3 mm (6.6 in. × 8.0 in. × 7.4 in.)

Tripod mounting UNC ¼"-20

  • Warranty
  • 2 years parts and labor coverage on the camera
  • 5 years coverage on the battery
  • 10 years coverage on the detector – the most vital part of the whole camera
  • List of contents
  • Infrared camera with lens
  • Battery (2 ea.)
  • Battery charger
  • Bluetooth headset
  • Calibration certificate
  • FLIR Tools+ license card
  • FLIR T10xx SC kit (in separate hard transport case):
  • High-speed interface
  • USB cable (USB 3), 3 m (10 ft.)
  • Digital I/O connector
  • FLIR ResearchIR Max license card
  • Printed documentation
  • Hard transport case
  • HDMI-HDMI cable
  • Lens cap
  • Memory card
  • Neck strap
  • Power supply, including multi-plugs
  • Printed documentation
  • USB cable, Std A to Micro-B

EAN-13 7332558010327

Show 6 more labels / short text on this page
Environmental data · Safety EN/UL/CSA/PSE 60950-1 · Physical data · Housing material Magnesium · Warranty information · Shipping information
Page 165 of the Flir T1020 user manual — Supplies & accessories
Page 165 · click to enlarge
Page 165

UPC-12 845188010966

Country of origin Sweden

Supplies & accessories

  • T199064; IR lens f=36mm (28°) with case
  • T199065; Close-up lens 3x (51 micron) with case
  • T199066; IR lens f=21.2mm (45°) with case
  • T199077; IR lens f=83.4mm (12°) with case
  • T910814; Power supply, incl. multi plugs
  • T198126; Battery charger, incl. power supply with multi plugs T6xx
  • T198506; Li-Ion Battery pack 3.7V 29Wh
  • T199406ACC; Battery Li-ion 3.7 V, 7.8 Ah, 29 Wh
  • T911230ACC; Memory card SDHC 4 GB
  • T198509; Cigarette lighter adapter kit, 12 VDC, 1.2 m/3.9 ft.
  • T910930ACC; HDMI type C to DVI cable 1.5 m
  • T910891ACC; HDMI type C to HDMI type A cable 1.5 m
  • 72500-0002; FLIR T10xx SC kit
  • T198497; Large eyecup
  • T197771ACC; Bluetooth Headset
  • T911093; Tool belt
  • T198533; USB cable Std A <-> Micro B
  • T198586; FLIR Reporter Professional (license only)
  • T198584; FLIR Tools
  • T198583; FLIR Tools+ (download card incl. license key)
  • DSW-10000; FLIR IR Camera Player
  • APP-10002; FLIR Tools Mobile (Android Application)
  • APP-10003; FLIR Tools Mobile (iPad/iPhone Application)
  • APP-10004; FLIR Tools (MacOS Application)
  • T198697; FLIR ResearchIR Max + HSDR 4 (hardware sec. dev.)
  • T199014; FLIR ResearchIR Max + HSDR 4 (printed license key)
  • T199044; FLIR ResearchIR Max + HSDR 4 Upgrade (printed license key)
  • T198696; FLIR ResearchIR Max 4 (hardware sec. dev.)
  • T199013; FLIR ResearchIR Max 4 (printed license key)
  • T199043; FLIR ResearchIR Max 4 Upgrade (printed license key)
  • T198731; FLIR ResearchIR Standard 4 (hardware sec. dev.)
  • T199012; FLIR ResearchIR Standard 4 (printed license key)
  • T199042; FLIR ResearchIR Standard 4 Upgrade (printed license key)
  • T199233; FLIR Atlas SDK for .NET
  • T199234; FLIR Atlas SDK for MATLAB

Shipping information

Page 166 of the Flir T1020 user manual — 26.13 FLIR T1040 12°
Page 166 · click to enlarge
Page 166

26.13 FLIR T1040 12°

P/N72501-0301 Rev.: 36730

The FLIR T1040 is designed for the expert requiring the highest performance and the latest technology available. The camera combines excellent ergonomics and feature-rich flexibility with superior image quality at an infrared resolution of 1024 × 768 pixels.

Benefits:

  • Flexible and feature rich: A wide variety of measuring and analysis functions make the FLIR T1040 flexible for your every need. Two programmable buttons provide easy access to favorite functions.
  • Highest performance with the latest technology: The FLIR T1040 is equipped with the innovative Multi Spectral Dynamic Imaging (MSX) feature, which produces an image richer in detail than ever before. With its continuous autofocus, the FLIR T1040 is a fully automatic infrared camera.
  • Support for UltraMax: When enabling UltraMax in the camera, the resolution of images can be substantially enhanced when importing the images into FLIR Tools.

Imaging and optical data

IR resolution 1024 × 768 pixels

MSX resolution 1024 × 768 pixels

Thermal sensitivity/NETD

Field of view (FOV) 12° × 9°

Minimum IR focus distance 1.3 m (4.26 ft.)

Minimum IR–visual alignment distance 1.3 m (4.26 ft.)

Focal length 83.4 mm (3.28 in.)

Spatial resolution (IFOV) 0.20 mrad

F-number 1.2

Image frequency 30 Hz

Focus One shot or manual

Digital zoom 1–8× continuous

Digital image enhancement Adaptive digital noise reduction

Detector type Focal plane array (FPA), uncooled microbolometer

Spectral range 7.5–14 µm

Detector pitch 17 µm

Display Built-in touch screen, 4.3 in. wide screen LCD, 800 × 480 pixels

Display type Capacitive touch screen

Auto orientation Automatic landscape or portrait

Viewfinder Built-in 800 × 480 pixels

Automatic image adjustment Continuous, histogram based

Show 5 more labels / short text on this page
General description · UltraMax Yes · Lens identification Automatic · Detector data · Image presentation
Page 167 of the Flir T1020 user manual — NOTE
Page 167 · click to enlarge
Page 167

Automatic image adjustment, type Standard or histogram based on the image content

Manual image adjustment Linear based, possible to adjust level/span/max./ min.

Image modes Thermal, thermal MSX, picture in picture, digital camera

Infrared image Full color infrared image

Visual image Full color visual image

Multi Spectral Dynamic Imaging (MSX) Thermal image with enhanced detail presentation

Picture in Picture Resizable and movable infrared area on the visual image

  • Gallery
  • Review thumbnail/full image on the camera
  • Edit measurements/palettes/image modes on the camera
  • Object temperature range
  • –40 to +150°C (–40 to +302°F)
  • 0 to +650°C (+32 to +1202°F)
  • +300 to +2000°C (+572 to +3632°F)
  • Accuracy
  • ±1°C (±1.8°F) or ±1% @ 25°C (77°F) for temperatures between 5 and 150°C (41 and 302° F), in range –40 to 150°C (–40 to 302°F)
  • ±2°C (±3.6°F) or ±2% of reading @ 25°C (77° F) for temperatures between –40 and 2000°C (–40 and 3632°F)

NOTE

For HSI use, above 30 Hz frame rate, the typical accuracy will be ±2.5°C (±4.5°F), or 2.5% of reading @ 25°C (77°F).

Area 5 + 5 areas (boxes and circles) with max./min./ average

Profile 1 line profile with max./min. temperature

Automatic hot/cold detection Auto hot or cold spotmeter markers within the area and profile

Measurement presets No measurements, Center spot, Hot spot, Cold spot, User preset 1, User preset 2

User presets The user can select and combine measurements from any number of spots/boxes/circles/profiles/ delta

Difference temperature Delta temperature between the measurement func- tions and the reference temperature

Reference temperature Manually set using the difference temperature

Atmospheric transmission correction Automatic, based on the inputs for distance, at- mospheric temperature, and relative humidity

Optics transmission correction Automatic, based on signals from internal sensors

Show 5 more labels / short text on this page
Image presentation · Image presentation modes · Measurement · Measurement analysis · Spotmeter 10
Page 168 of the Flir T1020 user manual — 26.13 FLIR T1040 12°
Page 168 · click to enlarge
Page 168

Emissivity correction Variable from 0.01 to 1.0 or selected from the ma- terials list

Reflected apparent temperature correction Automatic, based on the input of the reflected temperature

External optics/windows correction Automatic, based on the inputs of the window transmission and temperature

Measurement corrections Emissivity, reflected temperature, relative humidity, atmospheric temperature, object distance, external infrared window compensation

Colors (palettes) Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava

Color Alarm (isotherm) Above/below/interval

Measurement function alarm Audible/visual alarms (above/below) on any se- lected measurement function

Set-up commands Define user presets, Save options, Programmable button, Reset options, Set up camera, Wi-Fi, GPS & compass, Bluetooth, Language, Time & units, Camera information

Languages Arabic, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japa- nese, Korean, Norwegian, Polish, Portuguese, Russian, simplified Chinese, Swedish, traditional Chinese, Turkish

Camera software update Use PC software FLIR Tools

Image storage Standard JPEG, including digital image and meas- urement data, on a memory card

Storage media Removable media SD or SDHC card. Class 10 or better recommended

  • Image storage mode
  • Simultaneous storage of thermal and digital images in the same JPEG file
  • Option to store a digital photo as a separate JPEG file

Time lapse 15 seconds to 24 hours

  • File formats
  • Standard JPEG, measurement data included
  • CSQ, measurement data included

File formats, visual Standard JPEG, automatically associated with the corresponding thermal image

Voice 60 seconds (via Bluetooth) stored with the image

Text Add table, select between predefined templates

Show 6 more labels / short text on this page
Measurement analysis · Alarm · Set-up · Service functions · Storage of images · Image annotations
Page 169 of the Flir T1020 user manual — 26.13 FLIR T1040 12°
Page 169 · click to enlarge
Page 169

Image description Add short note (stored in the JPEG exif tag)

  • Sketch
  • Draw on the thermal/digital image or add predefined stamps
  • Separate PC software with extensive report generation

GPS Location data automatically added to every image from the built-in GPS

Compass Camera direction automatically added to every image

Video recording in camera

Radiometric IR-video recording Real-time radiometric recording (RTRR) to the memory card

Non-radiometric IR-video recording H.264 to the memory card

Visual video recording H.264 to the memory card

Radiometric IR-video streaming Real-time radiometric streaming (RTRS) via USB

  • Non-radiometric IR-video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Visual video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB

Digital camera Field of view adapts to the infrared lens

Video lamp Built-in LED light

Laser Activated by a dedicated button

Laser alignment Position is automatically displayed on the infrared image

Laser classification Class 2

Laser type Semiconductor AlGaInP diode laser, 1 mW, 635 nm (red)

Interfaces USB Micro-B, Bluetooth, Wi-Fi, HDMI

Bluetooth Communication with a headset

Wi-Fi Infrastructure (network) or AP

SD Card One card slot for removable SD memory cards

Audio Microphone headset via Bluetooth for the voice an- notation of images

Show 6 more labels / short text on this page
Image annotations · Geographic Information System · Video streaming · Digital camera · Laser pointer · Data communication interfaces
Page 170 of the Flir T1020 user manual — USB
Page 170 · click to enlarge
Page 170

USB

USB USB Micro-Bdata transfer to and from a PC, uncompressed colorized video
  • USB, standard
  • USB 2.0 High Speed
  • USB Micro-B connector
  • Video out
  • HDMI 640 × 480
  • HDMI 1280 × 720
  • DVI 640 × 480
  • DVI 800 × 600

Video, connector type HDMI type C

  • Wi-Fi
  • Standard: 802.11 b/g/n
  • Frequency range: 2412–2462 MHz
  • Max. output power: 15 dBm
Bluetooth Frequency range2402–2480 MHz, supports 2.1, 4.0, and 4.0 BLE

Battery type Rechargeable Li ion battery

Battery operating time >2.5 hours at 25°C (+68°F) and typical use

Charging system In camera (AC adapter or 12 V from a vehicle) or two-bay charger

Charging time 2.5 hours to 90% capacity, charging status indi- cated by LEDs

Charging temperature 0–45°C (32–113°F)

External power operation AC adapter 90–260 V AC, 50/60 Hz or 12 V from a vehicle (cable with a standard plug, optional)

Power management Automatic power-off functionality, user configura- ble between 5 minutes, 20 minutes, and no auto- matic shutdown

Operating temperature range –15°C to +50°C (+5°F to +122°F)

Storage temperature range –40 to +70°C (–40 to +158°F)

Humidity (operating and storage) IEC 60068-2-30 / 24 hours, 95% relative humidity, 25–40°C (77–104°F) / 2 cycles

  • EMC
  • ETSI EN 301 489-1 (radio)
  • ETSI EN 301 489-17
  • EN 61000-6-2 (Immunity)
  • EN 61000-6-3 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
  • ICES-003
  • Radio spectrum
  • ETSI EN 300 328
  • FCC Part 15.247
  • RSS-247 issue 1

Encapsulation IP 54 (IEC 60529)

Shock 25 g (IEC 60068-2-29)

Show 5 more labels / short text on this page
Video · Radio · Antenna Internal · Power system · Environmental data
Page 171 of the Flir T1020 user manual — Supplies & accessories:
Page 171 · click to enlarge
Page 171

Vibration 2 g (IEC 60068-2-6)

Ergonomics The viewfinder plus the 120° rotating optical block allow you to point the camera in multiple directions while maintaining a comfortable position

Weight 2.1 kg (4.6 lb.)

Camera size, excl. lens (L × W × H) 167.2 mm × 204.5 mm × 188.3 mm (6.6 in. × 8.0 in. × 7.4 in.)

Tripod mounting UNC ¼"-20

  • Warranty
  • 2 years parts and labor coverage on the camera
  • 5 years coverage on the battery
  • 10 years coverage on the detector – the most vital part of the whole camera
  • List of contents
  • Infrared camera with lens
  • Battery (2 ea.)
  • Battery charger
  • Bluetooth headset
  • Calibration certificate
  • FLIR Tools+ license card
  • Hard transport case
  • HDMI-HDMI cable
  • Lens cap
  • Memory card
  • Neck strap
  • Power supply, including multi-plugs
  • Printed documentation
  • USB cable, Std A to Micro-B

EAN-13 7332558010389

UPC-12 845188011031

Country of origin Sweden

Supplies & accessories:

  • T199064; IR lens f=36mm (28°) with case
  • T199066; IR lens f=21.2mm (45°) with case
  • T199077; IR lens f=83.4mm (12°) with case
  • T910814; Power supply, incl. multi plugs
  • T198126; Battery charger, incl. power supply with multi plugs T6xx
  • T198506; Li-Ion Battery pack 3.7V 29Wh
  • T199406ACC; Battery Li-ion 3.7 V, 7.8 Ah, 29 Wh
  • T911230ACC; Memory card SDHC 4 GB
  • T198509; Cigarette lighter adapter kit, 12 VDC, 1.2 m/3.9 ft.
  • T910930ACC; HDMI type C to DVI cable 1.5 m
  • T910891ACC; HDMI type C to HDMI type A cable 1.5 m
  • T198497; Large eyecup
  • T197771ACC; Bluetooth Headset
Show 6 more labels / short text on this page
Environmental data · Safety EN/UL/CSA/PSE 60950-1 · Physical data · Housing material Magnesium · Warranty information · Shipping information
Page 172 of the Flir T1020 user manual — 26.13 FLIR T1040 12°
Page 172 · click to enlarge
Page 172
  • T911093; Tool belt
  • T198533; USB cable Std A <-> Micro B
  • T198586; FLIR Reporter Professional (license only)
  • T198584; FLIR Tools
  • T198583; FLIR Tools+ (download card incl. license key)
  • DSW-10000; FLIR IR Camera Player
  • APP-10002; FLIR Tools Mobile (Android Application)
  • APP-10003; FLIR Tools Mobile (iPad/iPhone Application)
  • APP-10004; FLIR Tools (MacOS Application)
  • T199233; FLIR Atlas SDK for .NET
  • T199234; FLIR Atlas SDK for MATLAB
Page 173 of the Flir T1020 user manual — 26.14 FLIR T1040 28°
Page 173 · click to enlarge
Page 173

26.14 FLIR T1040 28°

P/N72501-0302 Rev.: 36730

The FLIR T1040 is designed for the expert requiring the highest performance and the latest technology available. The camera combines excellent ergonomics and feature-rich flexibility with superior image quality at an infrared resolution of 1024 × 768 pixels.

Benefits:

  • Flexible and feature rich: A wide variety of measuring and analysis functions make the FLIR T1040 flexible for your every need. Two programmable buttons provide easy access to favorite functions.
  • Highest performance with the latest technology: The FLIR T1040 is equipped with the innovative Multi Spectral Dynamic Imaging (MSX) feature, which produces an image richer in detail than ever before. With its continuous autofocus, the FLIR T1040 is a fully automatic infrared camera.
  • Support for UltraMax: When enabling UltraMax in the camera, the resolution of images can be substantially enhanced when importing the images into FLIR Tools.

Imaging and optical data

IR resolution 1024 × 768 pixels

MSX resolution 1024 × 768 pixels

Thermal sensitivity/NETD

Field of view (FOV) 28° × 21°

Minimum IR focus distance 0.4 m (1.32 ft.)

Minimum IR–visual alignment distance 0.4 m (1.32 ft.)

Focal length 36 mm (1.42 in.)

Spatial resolution (IFOV) 0.47 mrad

F-number 1.15

Image frequency 30 Hz

Focus One shot or manual

Digital zoom 1–8× continuous

Digital image enhancement Adaptive digital noise reduction

Detector type Focal plane array (FPA), uncooled microbolometer

Spectral range 7.5–14 µm

Detector pitch 17 µm

Display Built-in touch screen, 4.3 in. wide screen LCD, 800 × 480 pixels

Display type Capacitive touch screen

Auto orientation Automatic landscape or portrait

Viewfinder Built-in 800 × 480 pixels

Automatic image adjustment Continuous, histogram based

Show 5 more labels / short text on this page
General description · UltraMax Yes · Lens identification Automatic · Detector data · Image presentation
Page 174 of the Flir T1020 user manual — NOTE
Page 174 · click to enlarge
Page 174

Automatic image adjustment, type Standard or histogram based on the image content

Manual image adjustment Linear based, possible to adjust level/span/max./ min.

Image modes Thermal, thermal MSX, picture in picture, digital camera

Infrared image Full color infrared image

Visual image Full color visual image

Multi Spectral Dynamic Imaging (MSX) Thermal image with enhanced detail presentation

Picture in Picture Resizable and movable infrared area on the visual image

  • Gallery
  • Review thumbnail/full image on the camera
  • Edit measurements/palettes/image modes on the camera
  • Object temperature range
  • –40 to +150°C (–40 to +302°F)
  • 0 to +650°C (+32 to +1202°F)
  • +300 to +2000°C (+572 to +3632°F)
  • Accuracy
  • ±1°C (±1.8°F) or ±1% @ 25°C (77°F) for temperatures between 5 and 150°C (41 and 302° F), in range –40 to 150°C (–40 to 302°F)
  • ±2°C (±3.6°F) or ±2% of reading @ 25°C (77° F) for temperatures between –40 and 2000°C (–40 and 3632°F)

NOTE

For HSI use, above 30 Hz frame rate, the typical accuracy will be ±2.5°C (±4.5°F), or 2.5% of reading @ 25°C (77°F).

Area 5 + 5 areas (boxes and circles) with max./min./ average

Profile 1 line profile with max./min. temperature

Automatic hot/cold detection Auto hot or cold spotmeter markers within the area and profile

Measurement presets No measurements, Center spot, Hot spot, Cold spot, User preset 1, User preset 2

User presets The user can select and combine measurements from any number of spots/boxes/circles/profiles/ delta

Difference temperature Delta temperature between the measurement func- tions and the reference temperature

Reference temperature Manually set using the difference temperature

Atmospheric transmission correction Automatic, based on the inputs for distance, at- mospheric temperature, and relative humidity

Optics transmission correction Automatic, based on signals from internal sensors

Show 5 more labels / short text on this page
Image presentation · Image presentation modes · Measurement · Measurement analysis · Spotmeter 10
Page 175 of the Flir T1020 user manual — 26.14 FLIR T1040 28°
Page 175 · click to enlarge
Page 175

Emissivity correction Variable from 0.01 to 1.0 or selected from the ma- terials list

Reflected apparent temperature correction Automatic, based on the input of the reflected temperature

External optics/windows correction Automatic, based on the inputs of the window transmission and temperature

Measurement corrections Emissivity, reflected temperature, relative humidity, atmospheric temperature, object distance, external infrared window compensation

Colors (palettes) Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava

Color Alarm (isotherm) Above/below/interval

Measurement function alarm Audible/visual alarms (above/below) on any se- lected measurement function

Set-up commands Define user presets, Save options, Programmable button, Reset options, Set up camera, Wi-Fi, GPS & compass, Bluetooth, Language, Time & units, Camera information

Languages Arabic, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japa- nese, Korean, Norwegian, Polish, Portuguese, Russian, simplified Chinese, Swedish, traditional Chinese, Turkish

Camera software update Use PC software FLIR Tools

Image storage Standard JPEG, including digital image and meas- urement data, on a memory card

Storage media Removable media SD or SDHC card. Class 10 or better recommended

  • Image storage mode
  • Simultaneous storage of thermal and digital images in the same JPEG file
  • Option to store a digital photo as a separate JPEG file

Time lapse 15 seconds to 24 hours

  • File formats
  • Standard JPEG, measurement data included
  • CSQ, measurement data included

File formats, visual Standard JPEG, automatically associated with the corresponding thermal image

Voice 60 seconds (via Bluetooth) stored with the image

Text Add table, select between predefined templates

Show 6 more labels / short text on this page
Measurement analysis · Alarm · Set-up · Service functions · Storage of images · Image annotations
Page 176 of the Flir T1020 user manual — 26.14 FLIR T1040 28°
Page 176 · click to enlarge
Page 176

Image description Add short note (stored in the JPEG exif tag)

  • Sketch
  • Draw on the thermal/digital image or add predefined stamps
  • Separate PC software with extensive report generation

GPS Location data automatically added to every image from the built-in GPS

Compass Camera direction automatically added to every image

Video recording in camera

Radiometric IR-video recording Real-time radiometric recording (RTRR) to the memory card

Non-radiometric IR-video recording H.264 to the memory card

Visual video recording H.264 to the memory card

Radiometric IR-video streaming Real-time radiometric streaming (RTRS) via USB

  • Non-radiometric IR-video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Visual video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB

Digital camera Field of view adapts to the infrared lens

Video lamp Built-in LED light

Laser Activated by a dedicated button

Laser alignment Position is automatically displayed on the infrared image

Laser classification Class 2

Laser type Semiconductor AlGaInP diode laser, 1 mW, 635 nm (red)

Interfaces USB Micro-B, Bluetooth, Wi-Fi, HDMI

Bluetooth Communication with a headset

Wi-Fi Infrastructure (network) or AP

SD Card One card slot for removable SD memory cards

Audio Microphone headset via Bluetooth for the voice an- notation of images

Show 6 more labels / short text on this page
Image annotations · Geographic Information System · Video streaming · Digital camera · Laser pointer · Data communication interfaces
Page 177 of the Flir T1020 user manual — USB
Page 177 · click to enlarge
Page 177

USB

USB USB Micro-Bdata transfer to and from a PC, uncompressed colorized video
  • USB, standard
  • USB 2.0 High Speed
  • USB Micro-B connector
  • Video out
  • HDMI 640 × 480
  • HDMI 1280 × 720
  • DVI 640 × 480
  • DVI 800 × 600

Video, connector type HDMI type C

  • Wi-Fi
  • Standard: 802.11 b/g/n
  • Frequency range: 2412–2462 MHz
  • Max. output power: 15 dBm
Bluetooth Frequency range2402–2480 MHz, supports 2.1, 4.0, and 4.0 BLE

Battery type Rechargeable Li ion battery

Battery operating time >2.5 hours at 25°C (+68°F) and typical use

Charging system In camera (AC adapter or 12 V from a vehicle) or two-bay charger

Charging time 2.5 hours to 90% capacity, charging status indi- cated by LEDs

Charging temperature 0–45°C (32–113°F)

External power operation AC adapter 90–260 V AC, 50/60 Hz or 12 V from a vehicle (cable with a standard plug, optional)

Power management Automatic power-off functionality, user configura- ble between 5 minutes, 20 minutes, and no auto- matic shutdown

Operating temperature range –15°C to +50°C (+5°F to +122°F)

Storage temperature range –40 to +70°C (–40 to +158°F)

Humidity (operating and storage) IEC 60068-2-30 / 24 hours, 95% relative humidity, 25–40°C (77–104°F) / 2 cycles

  • EMC
  • ETSI EN 301 489-1 (radio)
  • ETSI EN 301 489-17
  • EN 61000-6-2 (Immunity)
  • EN 61000-6-3 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
  • ICES-003
  • Radio spectrum
  • ETSI EN 300 328
  • FCC Part 15.247
  • RSS-247 issue 1

Encapsulation IP 54 (IEC 60529)

Shock 25 g (IEC 60068-2-29)

Show 5 more labels / short text on this page
Video · Radio · Antenna Internal · Power system · Environmental data
Page 178 of the Flir T1020 user manual — Supplies & accessories:
Page 178 · click to enlarge
Page 178

Vibration 2 g (IEC 60068-2-6)

Ergonomics The viewfinder plus the 120° rotating optical block allow you to point the camera in multiple directions while maintaining a comfortable position

Weight 1.9 kg (4.3 lb.)

Camera size, excl. lens (L × W × H) 167.2 mm × 204.5 mm × 188.3 mm (6.6 in. × 8.0 in. × 7.4 in.)

Tripod mounting UNC ¼"-20

  • Warranty
  • 2 years parts and labor coverage on the camera
  • 5 years coverage on the battery
  • 10 years coverage on the detector – the most vital part of the whole camera
  • List of contents
  • Infrared camera with lens
  • Battery (2 ea.)
  • Battery charger
  • Bluetooth headset
  • Calibration certificate
  • FLIR Tools+ license card
  • Hard transport case
  • HDMI-HDMI cable
  • Lens cap
  • Memory card
  • Neck strap
  • Power supply, including multi-plugs
  • Printed documentation
  • USB cable, Std A to Micro-B

EAN-13 7332558010396

UPC-12 845188011048

Country of origin Sweden

Supplies & accessories:

  • T199064; IR lens f=36mm (28°) with case
  • T199066; IR lens f=21.2mm (45°) with case
  • T199077; IR lens f=83.4mm (12°) with case
  • T910814; Power supply, incl. multi plugs
  • T198126; Battery charger, incl. power supply with multi plugs T6xx
  • T198506; Li-Ion Battery pack 3.7V 29Wh
  • T199406ACC; Battery Li-ion 3.7 V, 7.8 Ah, 29 Wh
  • T911230ACC; Memory card SDHC 4 GB
  • T198509; Cigarette lighter adapter kit, 12 VDC, 1.2 m/3.9 ft.
  • T910930ACC; HDMI type C to DVI cable 1.5 m
  • T910891ACC; HDMI type C to HDMI type A cable 1.5 m
  • T198497; Large eyecup
  • T197771ACC; Bluetooth Headset
Show 6 more labels / short text on this page
Environmental data · Safety EN/UL/CSA/PSE 60950-1 · Physical data · Housing material Magnesium · Warranty information · Shipping information
Page 179 of the Flir T1020 user manual — 26.14 FLIR T1040 28°
Page 179 · click to enlarge
Page 179
  • T911093; Tool belt
  • T198533; USB cable Std A <-> Micro B
  • T198586; FLIR Reporter Professional (license only)
  • T198584; FLIR Tools
  • T198583; FLIR Tools+ (download card incl. license key)
  • DSW-10000; FLIR IR Camera Player
  • APP-10002; FLIR Tools Mobile (Android Application)
  • APP-10003; FLIR Tools Mobile (iPad/iPhone Application)
  • APP-10004; FLIR Tools (MacOS Application)
  • T199233; FLIR Atlas SDK for .NET
  • T199234; FLIR Atlas SDK for MATLAB
Page 180 of the Flir T1020 user manual — 26.15 FLIR T1040 45°
Page 180 · click to enlarge
Page 180

26.15 FLIR T1040 45°

P/N72501-0303 Rev.: 36730

The FLIR T1040 is designed for the expert requiring the highest performance and the latest technology available. The camera combines excellent ergonomics and feature-rich flexibility with superior image quality at an infrared resolution of 1024 × 768 pixels.

Benefits:

  • Flexible and feature rich: A wide variety of measuring and analysis functions make the FLIR T1040 flexible for your every need. Two programmable buttons provide easy access to favorite functions.
  • Highest performance with the latest technology: The FLIR T1040 is equipped with the innovative Multi Spectral Dynamic Imaging (MSX) feature, which produces an image richer in detail than ever before. With its continuous autofocus, the FLIR T1040 is a fully automatic infrared camera.
  • Support for UltraMax: When enabling UltraMax in the camera, the resolution of images can be substantially enhanced when importing the images into FLIR Tools.

Imaging and optical data

IR resolution 1024 × 768 pixels

MSX resolution 1024 × 768 pixels

Thermal sensitivity/NETD

Field of view (FOV) 45° × 34°

Minimum IR focus distance 0.2 m (0.66 ft.)

Minimum IR–visual alignment distance 0.5 m (1.64 ft.)

Focal length 21.2 mm (0.83 in.)

Spatial resolution (IFOV) 0.80 mrad

F-number 1.1

Image frequency 30 Hz

Focus One shot or manual

Digital zoom 1–8× continuous

Digital image enhancement Adaptive digital noise reduction

Detector type Focal plane array (FPA), uncooled microbolometer

Spectral range 7.5–14 µm

Detector pitch 17 µm

Display Built-in touch screen, 4.3 in. wide screen LCD, 800 × 480 pixels

Display type Capacitive touch screen

Auto orientation Automatic landscape or portrait

Viewfinder Built-in 800 × 480 pixels

Automatic image adjustment Continuous, histogram based

Show 5 more labels / short text on this page
General description · UltraMax Yes · Lens identification Automatic · Detector data · Image presentation
Page 181 of the Flir T1020 user manual — NOTE
Page 181 · click to enlarge
Page 181

Automatic image adjustment, type Standard or histogram based on the image content

Manual image adjustment Linear based, possible to adjust level/span/max./ min.

Image modes Thermal, thermal MSX, picture in picture, digital camera

Infrared image Full color infrared image

Visual image Full color visual image

Multi Spectral Dynamic Imaging (MSX) Thermal image with enhanced detail presentation

Picture in Picture Resizable and movable infrared area on the visual image

  • Gallery
  • Review thumbnail/full image on the camera
  • Edit measurements/palettes/image modes on the camera
  • Object temperature range
  • –40 to +150°C (–40 to +302°F)
  • 0 to +650°C (+32 to +1202°F)
  • +300 to +2000°C (+572 to +3632°F)
  • Accuracy
  • ±1°C (±1.8°F) or ±1% @ 25°C (77°F) for temperatures between 5 and 150°C (41 and 302° F), in range –40 to 150°C (–40 to 302°F)
  • ±2°C (±3.6°F) or ±2% of reading @ 25°C (77° F) for temperatures between –40 and 2000°C (–40 and 3632°F)

NOTE

For HSI use, above 30 Hz frame rate, the typical accuracy will be ±2.5°C (±4.5°F), or 2.5% of reading @ 25°C (77°F).

Area 5 + 5 areas (boxes and circles) with max./min./ average

Profile 1 line profile with max./min. temperature

Automatic hot/cold detection Auto hot or cold spotmeter markers within the area and profile

Measurement presets No measurements, Center spot, Hot spot, Cold spot, User preset 1, User preset 2

User presets The user can select and combine measurements from any number of spots/boxes/circles/profiles/ delta

Difference temperature Delta temperature between the measurement func- tions and the reference temperature

Reference temperature Manually set using the difference temperature

Atmospheric transmission correction Automatic, based on the inputs for distance, at- mospheric temperature, and relative humidity

Optics transmission correction Automatic, based on signals from internal sensors

Show 5 more labels / short text on this page
Image presentation · Image presentation modes · Measurement · Measurement analysis · Spotmeter 10
Page 182 of the Flir T1020 user manual — 26.15 FLIR T1040 45°
Page 182 · click to enlarge
Page 182

Emissivity correction Variable from 0.01 to 1.0 or selected from the ma- terials list

Reflected apparent temperature correction Automatic, based on the input of the reflected temperature

External optics/windows correction Automatic, based on the inputs of the window transmission and temperature

Measurement corrections Emissivity, reflected temperature, relative humidity, atmospheric temperature, object distance, external infrared window compensation

Colors (palettes) Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava

Color Alarm (isotherm) Above/below/interval

Measurement function alarm Audible/visual alarms (above/below) on any se- lected measurement function

Set-up commands Define user presets, Save options, Programmable button, Reset options, Set up camera, Wi-Fi, GPS & compass, Bluetooth, Language, Time & units, Camera information

Languages Arabic, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japa- nese, Korean, Norwegian, Polish, Portuguese, Russian, simplified Chinese, Swedish, traditional Chinese, Turkish

Camera software update Use PC software FLIR Tools

Image storage Standard JPEG, including digital image and meas- urement data, on a memory card

Storage media Removable media SD or SDHC card. Class 10 or better recommended

  • Image storage mode
  • Simultaneous storage of thermal and digital images in the same JPEG file
  • Option to store a digital photo as a separate JPEG file

Time lapse 15 seconds to 24 hours

  • File formats
  • Standard JPEG, measurement data included
  • CSQ, measurement data included

File formats, visual Standard JPEG, automatically associated with the corresponding thermal image

Voice 60 seconds (via Bluetooth) stored with the image

Text Add table, select between predefined templates

Show 6 more labels / short text on this page
Measurement analysis · Alarm · Set-up · Service functions · Storage of images · Image annotations
Page 183 of the Flir T1020 user manual — 26.15 FLIR T1040 45°
Page 183 · click to enlarge
Page 183

Image description Add short note (stored in the JPEG exif tag)

  • Sketch
  • Draw on the thermal/digital image or add predefined stamps
  • Separate PC software with extensive report generation

GPS Location data automatically added to every image from the built-in GPS

Compass Camera direction automatically added to every image

Video recording in camera

Radiometric IR-video recording Real-time radiometric recording (RTRR) to the memory card

Non-radiometric IR-video recording H.264 to the memory card

Visual video recording H.264 to the memory card

Radiometric IR-video streaming Real-time radiometric streaming (RTRS) via USB

  • Non-radiometric IR-video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Visual video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB

Digital camera Field of view adapts to the infrared lens

Video lamp Built-in LED light

Laser Activated by a dedicated button

Laser alignment Position is automatically displayed on the infrared image

Laser classification Class 2

Laser type Semiconductor AlGaInP diode laser, 1 mW, 635 nm (red)

Interfaces USB Micro-B, Bluetooth, Wi-Fi, HDMI

Bluetooth Communication with a headset

Wi-Fi Infrastructure (network) or AP

SD Card One card slot for removable SD memory cards

Audio Microphone headset via Bluetooth for the voice an- notation of images

Show 6 more labels / short text on this page
Image annotations · Geographic Information System · Video streaming · Digital camera · Laser pointer · Data communication interfaces
Page 184 of the Flir T1020 user manual — USB
Page 184 · click to enlarge
Page 184

USB

USB USB Micro-Bdata transfer to and from a PC, uncompressed colorized video
  • USB, standard
  • USB 2.0 High Speed
  • USB Micro-B connector
  • Video out
  • HDMI 640 × 480
  • HDMI 1280 × 720
  • DVI 640 × 480
  • DVI 800 × 600

Video, connector type HDMI type C

  • Wi-Fi
  • Standard: 802.11 b/g/n
  • Frequency range: 2412–2462 MHz
  • Max. output power: 15 dBm
Bluetooth Frequency range2402–2480 MHz, supports 2.1, 4.0, and 4.0 BLE

Battery type Rechargeable Li ion battery

Battery operating time >2.5 hours at 25°C (+68°F) and typical use

Charging system In camera (AC adapter or 12 V from a vehicle) or two-bay charger

Charging time 2.5 hours to 90% capacity, charging status indi- cated by LEDs

Charging temperature 0–45°C (32–113°F)

External power operation AC adapter 90–260 V AC, 50/60 Hz or 12 V from a vehicle (cable with a standard plug, optional)

Power management Automatic power-off functionality, user configura- ble between 5 minutes, 20 minutes, and no auto- matic shutdown

Operating temperature range –15°C to +50°C (+5°F to +122°F)

Storage temperature range –40 to +70°C (–40 to +158°F)

Humidity (operating and storage) IEC 60068-2-30 / 24 hours, 95% relative humidity, 25–40°C (77–104°F) / 2 cycles

  • EMC
  • ETSI EN 301 489-1 (radio)
  • ETSI EN 301 489-17
  • EN 61000-6-2 (Immunity)
  • EN 61000-6-3 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
  • ICES-003
  • Radio spectrum
  • ETSI EN 300 328
  • FCC Part 15.247
  • RSS-247 issue 1

Encapsulation IP 54 (IEC 60529)

Shock 25 g (IEC 60068-2-29)

Show 5 more labels / short text on this page
Video · Radio · Antenna Internal · Power system · Environmental data
Page 185 of the Flir T1020 user manual — Supplies & accessories:
Page 185 · click to enlarge
Page 185

Vibration 2 g (IEC 60068-2-6)

Ergonomics The viewfinder plus the 120° rotating optical block allow you to point the camera in multiple directions while maintaining a comfortable position

Weight 2.0 kg (4.3 lb.)

Camera size, excl. lens (L × W × H) 167.2 mm × 204.5 mm × 188.3 mm (6.6 in. × 8.0 in. × 7.4 in.)

Tripod mounting UNC ¼"-20

  • Warranty
  • 2 years parts and labor coverage on the camera
  • 5 years coverage on the battery
  • 10 years coverage on the detector – the most vital part of the whole camera
  • List of contents
  • Infrared camera with lens
  • Battery (2 ea.)
  • Battery charger
  • Bluetooth headset
  • Calibration certificate
  • FLIR Tools+ license card
  • Hard transport case
  • HDMI-HDMI cable
  • Lens cap
  • Memory card
  • Neck strap
  • Power supply, including multi-plugs
  • Printed documentation
  • USB cable, Std A to Micro-B

EAN-13 7332558010402

UPC-12 845188011055

Country of origin Sweden

Supplies & accessories:

  • T199064; IR lens f=36mm (28°) with case
  • T199066; IR lens f=21.2mm (45°) with case
  • T199077; IR lens f=83.4mm (12°) with case
  • T910814; Power supply, incl. multi plugs
  • T198126; Battery charger, incl. power supply with multi plugs T6xx
  • T198506; Li-Ion Battery pack 3.7V 29Wh
  • T199406ACC; Battery Li-ion 3.7 V, 7.8 Ah, 29 Wh
  • T911230ACC; Memory card SDHC 4 GB
  • T198509; Cigarette lighter adapter kit, 12 VDC, 1.2 m/3.9 ft.
  • T910930ACC; HDMI type C to DVI cable 1.5 m
  • T910891ACC; HDMI type C to HDMI type A cable 1.5 m
  • T198497; Large eyecup
  • T197771ACC; Bluetooth Headset
Show 6 more labels / short text on this page
Environmental data · Safety EN/UL/CSA/PSE 60950-1 · Physical data · Housing material Magnesium · Warranty information · Shipping information
Page 186 of the Flir T1020 user manual — 26.15 FLIR T1040 45°
Page 186 · click to enlarge
Page 186
  • T911093; Tool belt
  • T198533; USB cable Std A <-> Micro B
  • T198586; FLIR Reporter Professional (license only)
  • T198584; FLIR Tools
  • T198583; FLIR Tools+ (download card incl. license key)
  • DSW-10000; FLIR IR Camera Player
  • APP-10002; FLIR Tools Mobile (Android Application)
  • APP-10003; FLIR Tools Mobile (iPad/iPhone Application)
  • APP-10004; FLIR Tools (MacOS Application)
  • T199233; FLIR Atlas SDK for .NET
  • T199234; FLIR Atlas SDK for MATLAB
Page 187 of the Flir T1020 user manual — 26.16 FLIR T1050sc 12°
Page 187 · click to enlarge
Page 187

26.16 FLIR T1050sc 12°

P/N72501-0401 Rev.: 36739

The FLIR T1050sc is designed for the expert requiring the highest performance and the latest technology available. The camera combines excellent ergonomics and feature-rich flexibility with superior image quality at an infrared resolution of 1024 × 768 pixels. High accuracy and sensitivity together with radio- metric recording and streaming options make the FLIR T1050sc well suited for advanced research and development.

Benefits:

  • Tailor made for research and development: The FLIR T1050sc has high accuracy and high sensitivity, to accurately measure the smallest temperature differences. With real-time radiometric recording, it is possible to capture fast events on the camera’s SD card for further analysis by the supplied analysis software.
  • Flexible and feature rich: A wide variety of measuring and analysis functions make the FLIR T1050sc flexible for your every need. Two programmable buttons provide easy access to favorite functions.
  • Highest performance with the latest technology: The FLIR T1050sc is equipped with the innovative Multi Spectral Dynamic Imaging (MSX) feature, which produces an image richer in detail than ever before. With its continuous autofocus, the FLIR T1050sc is a fully automatic infrared camera.
  • Support for UltraMax: When enabling UltraMax in the camera, the resolution of images can be substantially enhanced when importing the images into FLIR Tools.

Imaging and optical data

IR resolution 1024 × 768 pixels

MSX resolution 1024 × 768 pixels

Thermal sensitivity/NETD

Field of view (FOV) 12° × 9°

Minimum IR focus distance 1.3 m (4.26 ft.)

Minimum IR–visual alignment distance 1.3 m (4.26 ft.)

Focal length 83.4 mm (3.28 in.)

Spatial resolution (IFOV) 0.20 mrad

F-number 1.2

Image frequency 30 Hz

Focus One shot or manual

Digital zoom 1–8× continuous

Digital image enhancement Adaptive digital noise reduction

Detector type Focal plane array (FPA), uncooled microbolometer

Spectral range 7.5–14 µm

Detector pitch 17 µm

Time constant < 10 ms

Display Built-in touch screen, 4.3 in. wide screen LCD, 800 × 480 pixels

Display type Capacitive touch screen

Show 5 more labels / short text on this page
General description · UltraMax Yes · Lens identification Automatic · Detector data · Image presentation
Page 188 of the Flir T1020 user manual — NOTE
Page 188 · click to enlarge
Page 188

Auto orientation Automatic landscape or portrait

Viewfinder Built-in 800 × 480 pixels

Automatic image adjustment Continuous, histogram based

Automatic image adjustment, type Standard or histogram based on the image content

Manual image adjustment Linear based, possible to adjust level/span/max./ min.

Image modes Thermal, thermal MSX, picture in picture, digital camera

Infrared image Full color infrared image

Visual image Full color visual image

Multi Spectral Dynamic Imaging (MSX) Thermal image with enhanced detail presentation

Picture in Picture Resizable and movable infrared area on the visual image

  • Gallery
  • Review thumbnail/full image on the camera
  • Edit measurements/palettes/image modes on the camera
  • Object temperature range
  • –40 to +150°C (–40 to +302°F)
  • 0 to +650°C (+32 to +1202°F)
  • +300 to +2000°C (+572 to +3632°F)
  • Accuracy
  • ±1°C (±1.8°F) or ±1% @ 25°C (77°F) for temperatures between 5 and 150°C (41 and 302° F), in range –40 to 150°C (–40 to 302°F)
  • ±2°C (±3.6°F) or ±2% of reading @ 25°C (77° F) for temperatures between –40 and 2000°C (–40 and 3632°F)

NOTE

For HSI (high-speed interface) use, above 30 Hz frame rate, the typical accuracy will be ±2.5° C (±4.5°F), or 2.5% of reading @ 25°C (77°F).

Area 5 + 5 areas (boxes and circles) with max./min./ average

Profile 1 line profile with max./min. temperature

Automatic hot/cold detection Auto hot or cold spotmeter markers within the area and profile

Measurement presets No measurements, Center spot, Hot spot, Cold spot, User preset 1, User preset 2

User presets The user can select and combine measurements from any number of spots/boxes/circles/profiles/ delta

Difference temperature Delta temperature between the measurement func- tions and the reference temperature

Show 5 more labels / short text on this page
Image presentation · Image presentation modes · Measurement · Measurement analysis · Spotmeter 10
Page 189 of the Flir T1020 user manual — 26.16 FLIR T1050sc 12°
Page 189 · click to enlarge
Page 189

Reference temperature Manually set using the difference temperature

Atmospheric transmission correction Automatic, based on the inputs for distance, at- mospheric temperature, and relative humidity

Optics transmission correction Automatic, based on signals from internal sensors

Emissivity correction Variable from 0.01 to 1.0 or selected from the ma- terials list

Reflected apparent temperature correction Automatic, based on the input of the reflected temperature

External optics/windows correction Automatic, based on the inputs of the window transmission and temperature

Measurement corrections Emissivity, reflected temperature, relative humidity, atmospheric temperature, object distance, external infrared window compensation

Colors (palettes) Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava

Color Alarm (isotherm) Above/below/interval

Measurement function alarm Audible/visual alarms (above/below) on any se- lected measurement function

Set-up commands Define user presets, Save options, Programmable button, Reset options, Set up camera, Wi-Fi, GPS & compass, Bluetooth, Language, Time & units, Camera information

Languages Arabic, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japa- nese, Korean, Norwegian, Polish, Portuguese, Russian, simplified Chinese, Swedish, traditional Chinese, Turkish

Camera software update Use PC software FLIR Tools

Image storage Standard JPEG, including digital image and meas- urement data, on a memory card

Storage media Removable media SD or SDHC card. Class 10 or better recommended

  • Image storage mode
  • Simultaneous storage of thermal and digital images in the same JPEG file
  • Option to store a digital photo as a separate JPEG file

Time lapse 15 seconds to 24 hours

  • File formats
  • Standard JPEG, measurement data included
  • CSQ, measurement data included

File formats, visual Standard JPEG, automatically associated with the corresponding thermal image

Show 5 more labels / short text on this page
Measurement analysis · Alarm · Set-up · Service functions · Storage of images
Page 190 of the Flir T1020 user manual — 26.16 FLIR T1050sc 12°
Page 190 · click to enlarge
Page 190

Voice 60 seconds (via Bluetooth) stored with the image

Text Add table, select between predefined templates

Image description Add short note (stored in the JPEG exif tag)

  • Sketch
  • Draw on the thermal/digital image or add predefined stamps
  • Separate PC software with extensive report generation

GPS Location data automatically added to every image from the built-in GPS

Compass Camera direction automatically added to every image

Video recording in camera

Radiometric IR-video recording Real-time radiometric recording (RTRR) to the memory card

Non-radiometric IR-video recording H.264 to the memory card

Visual video recording H.264 to the memory card

  • Radiometric IR-video streaming
  • Full dynamic un-compressed 120 Hz 16-bit full frame (2 Gbit) to a PC using an HSI box
  • Real-time radiometric streaming 30 Hz (RTRS) via USB
  • Non-radiometric IR-video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Visual video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Windowing
  • 30 Hz: 1024 × 768 (full image height)
  • Based on 30 Hz: 120 Hz windowing 1024 × 192 (¼ of full image height), for range –40 to +150°C (–40 to +302°F)
  • 120 Hz: 1024 × 768 (full image height)
  • Based on 120 Hz: 240 Hz windowing 1024 × 384 (½ of full image height), for range 0 to +650°C (+32 to +1202°F) and range +300 to +2000°C (+572 to +3632°F)

Digital camera Field of view adapts to the infrared lens

Video lamp Built-in LED light

Laser Activated by a dedicated button

Laser alignment Position is automatically displayed on the infrared image

Laser classification Class 2

Laser type Semiconductor AlGaInP diode laser, 1 mW, 635 nm (red)

Show 5 more labels / short text on this page
Image annotations · Geographic Information System · Video streaming · Digital camera · Laser pointer
Page 191 of the Flir T1020 user manual — USB
Page 191 · click to enlarge
Page 191

Interfaces USB Micro-B, Bluetooth, Wi-Fi, HDMI, USB3 Vi- sion via HSI box

Bluetooth Communication with a headset

Wi-Fi Infrastructure (network) or AP

SD Card One card slot for removable SD memory cards

Audio Microphone headset via Bluetooth for the voice an- notation of images

USB

USB USB Micro-Bdata transfer to and from a PC, uncompressed colorized video
  • USB, standard
  • USB 2.0 High Speed
  • USB Micro-B connector
  • USB3 Vision via HSI box
  • Video out
  • HDMI 640 × 480
  • HDMI 1280 × 720
  • DVI 640 × 480
  • DVI 800 × 600

Video, connector type HDMI type C

  • Wi-Fi
  • Standard: 802.11 b/g/n
  • Frequency range: 2412–2462 MHz
  • Max. output power: 15 dBm
Bluetooth Frequency range2402–2480 MHz, supports 2.1, 4.0, and 4.0 BLE

Battery type Rechargeable Li ion battery

Battery operating time >2.5 hours at 25°C (+68°F) and typical use

Charging system In camera (AC adapter or 12 V from a vehicle) or two-bay charger

Charging time 2.5 hours to 90% capacity, charging status indi- cated by LEDs

Charging temperature 0–45°C (32–113°F)

External power operation AC adapter 90–260 V AC, 50/60 Hz or 12 V from a vehicle (cable with a standard plug, optional)

Power management Automatic power-off functionality, user configura- ble between 5 minutes, 20 minutes, and no auto- matic shutdown

Operating temperature range –15°C to +50°C (+5°F to +122°F)

Storage temperature range –40 to +70°C (–40 to +158°F)

Humidity (operating and storage) IEC 60068-2-30 / 24 hours, 95% relative humidity, 25–40°C (77–104°F) / 2 cycles

Show 6 more labels / short text on this page
Data communication interfaces · Video · Radio · Antenna Internal · Power system · Environmental data
Page 192 of the Flir T1020 user manual — EAN-13 7332558010419
Page 192 · click to enlarge
Page 192
  • EMC
  • ETSI EN 301 489-1 (radio)
  • ETSI EN 301 489-17
  • EN 61000-6-2 (Immunity)
  • EN 61000-6-3 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
  • ICES-003
  • Radio spectrum
  • ETSI EN 300 328
  • FCC Part 15.247
  • RSS-247 issue 1

Encapsulation IP 54 (IEC 60529)

Shock 25 g (IEC 60068-2-29)

Vibration 2 g (IEC 60068-2-6)

Ergonomics The viewfinder plus the 120° rotating optical block allow you to point the camera in multiple directions while maintaining a comfortable position

Weight 2.1 kg (4.6 lb.)

Camera size, excl. lens (L × W × H) 167.2 mm × 204.5 mm × 188.3 mm (6.6 in. × 8.0 in. × 7.4 in.)

Tripod mounting UNC ¼"-20

  • Warranty
  • 2 years parts and labor coverage on the camera
  • 5 years coverage on the battery
  • 10 years coverage on the detector – the most vital part of the whole camera
  • List of contents
  • Infrared camera with lens
  • Battery (2 ea.)
  • Battery charger
  • Bluetooth headset
  • Calibration certificate
  • FLIR Tools+ license card
  • FLIR T10xx SC kit (in separate hard transport case):
  • High-speed interface
  • USB cable (USB 3), 3 m (10 ft.)
  • Digital I/O connector
  • FLIR ResearchIR Max license card
  • Printed documentation
  • Hard transport case
  • HDMI-HDMI cable
  • Lens cap
  • Memory card
  • Neck strap
  • Power supply, including multi-plugs
  • Printed documentation
  • USB cable, Std A to Micro-B

EAN-13 7332558010419

Show 6 more labels / short text on this page
Environmental data · Safety EN/UL/CSA/PSE 60950-1 · Physical data · Housing material Magnesium · Warranty information · Shipping information
Page 193 of the Flir T1020 user manual — Supplies & accessories
Page 193 · click to enlarge
Page 193

UPC-12 845188011062

Country of origin Sweden

Supplies & accessories

  • T199064; IR lens f=36mm (28°) with case
  • T199065; Close-up lens 3x (51 micron) with case
  • T199066; IR lens f=21.2mm (45°) with case
  • T199077; IR lens f=83.4mm (12°) with case
  • T910814; Power supply, incl. multi plugs
  • T198126; Battery charger, incl. power supply with multi plugs T6xx
  • T198506; Li-Ion Battery pack 3.7V 29Wh
  • T199406ACC; Battery Li-ion 3.7 V, 7.8 Ah, 29 Wh
  • T911230ACC; Memory card SDHC 4 GB
  • T198509; Cigarette lighter adapter kit, 12 VDC, 1.2 m/3.9 ft.
  • T910930ACC; HDMI type C to DVI cable 1.5 m
  • T910891ACC; HDMI type C to HDMI type A cable 1.5 m
  • 72500-0002; FLIR T10xx SC kit
  • T198497; Large eyecup
  • T197771ACC; Bluetooth Headset
  • T911093; Tool belt
  • T198533; USB cable Std A <-> Micro B
  • T198586; FLIR Reporter Professional (license only)
  • T198584; FLIR Tools
  • T198583; FLIR Tools+ (download card incl. license key)
  • DSW-10000; FLIR IR Camera Player
  • APP-10002; FLIR Tools Mobile (Android Application)
  • APP-10003; FLIR Tools Mobile (iPad/iPhone Application)
  • APP-10004; FLIR Tools (MacOS Application)
  • T198697; FLIR ResearchIR Max + HSDR 4 (hardware sec. dev.)
  • T199014; FLIR ResearchIR Max + HSDR 4 (printed license key)
  • T199044; FLIR ResearchIR Max + HSDR 4 Upgrade (printed license key)
  • T198696; FLIR ResearchIR Max 4 (hardware sec. dev.)
  • T199013; FLIR ResearchIR Max 4 (printed license key)
  • T199043; FLIR ResearchIR Max 4 Upgrade (printed license key)
  • T198731; FLIR ResearchIR Standard 4 (hardware sec. dev.)
  • T199012; FLIR ResearchIR Standard 4 (printed license key)
  • T199042; FLIR ResearchIR Standard 4 Upgrade (printed license key)
  • T199233; FLIR Atlas SDK for .NET
  • T199234; FLIR Atlas SDK for MATLAB

Shipping information

Page 194 of the Flir T1020 user manual — 26.17 FLIR T1050sc 28°
Page 194 · click to enlarge
Page 194

26.17 FLIR T1050sc 28°

P/N72501-0402 Rev.: 36740

The FLIR T1050sc is designed for the expert requiring the highest performance and the latest technology available. The camera combines excellent ergonomics and feature-rich flexibility with superior image quality at an infrared resolution of 1024 × 768 pixels. High accuracy and sensitivity together with radio- metric recording and streaming options make the FLIR T1050sc well suited for advanced research and development.

Benefits:

  • Tailor made for research and development: The FLIR T1050sc has high accuracy and high sensitivity, to accurately measure the smallest temperature differences. With real-time radiometric recording, it is possible to capture fast events on the camera’s SD card for further analysis by the supplied analysis software.
  • Flexible and feature rich: A wide variety of measuring and analysis functions make the FLIR T1050sc flexible for your every need. Two programmable buttons provide easy access to favorite functions.
  • Highest performance with the latest technology: The FLIR T1050sc is equipped with the innovative Multi Spectral Dynamic Imaging (MSX) feature, which produces an image richer in detail than ever before. With its continuous autofocus, the FLIR T1050sc is a fully automatic infrared camera.
  • Support for UltraMax: When enabling UltraMax in the camera, the resolution of images can be substantially enhanced when importing the images into FLIR Tools.

Imaging and optical data

IR resolution 1024 × 768 pixels

MSX resolution 1024 × 768 pixels

Thermal sensitivity/NETD

Field of view (FOV) 28° × 21°

Minimum IR focus distance 0.4 m (1.32 ft.)

Minimum IR–visual alignment distance 0.4 m (1.32 ft.)

Focal length 36 mm (1.42 in.)

Spatial resolution (IFOV) 0.47 mrad

F-number 1.15

Image frequency 30 Hz

Focus One shot or manual

Digital zoom 1–8× continuous

Digital image enhancement Adaptive digital noise reduction

Detector type Focal plane array (FPA), uncooled microbolometer

Spectral range 7.5–14 µm

Detector pitch 17 µm

Time constant < 10 ms

Display Built-in touch screen, 4.3 in. wide screen LCD, 800 × 480 pixels

Display type Capacitive touch screen

Show 5 more labels / short text on this page
General description · UltraMax Yes · Lens identification Automatic · Detector data · Image presentation
Page 195 of the Flir T1020 user manual — NOTE
Page 195 · click to enlarge
Page 195

Auto orientation Automatic landscape or portrait

Viewfinder Built-in 800 × 480 pixels

Automatic image adjustment Continuous, histogram based

Automatic image adjustment, type Standard or histogram based on the image content

Manual image adjustment Linear based, possible to adjust level/span/max./ min.

Image modes Thermal, thermal MSX, picture in picture, digital camera

Infrared image Full color infrared image

Visual image Full color visual image

Multi Spectral Dynamic Imaging (MSX) Thermal image with enhanced detail presentation

Picture in Picture Resizable and movable infrared area on the visual image

  • Gallery
  • Review thumbnail/full image on the camera
  • Edit measurements/palettes/image modes on the camera
  • Object temperature range
  • –40 to +150°C (–40 to +302°F)
  • 0 to +650°C (+32 to +1202°F)
  • +300 to +2000°C (+572 to +3632°F)
  • Accuracy
  • ±1°C (±1.8°F) or ±1% @ 25°C (77°F) for temperatures between 5 and 150°C (41 and 302° F), in range –40 to 150°C (–40 to 302°F)
  • ±2°C (±3.6°F) or ±2% of reading @ 25°C (77° F) for temperatures between –40 and 2000°C (–40 and 3632°F)

NOTE

For HSI (high-speed interface) use, above 30 Hz frame rate, the typical accuracy will be ±2.5° C (±4.5°F), or 2.5% of reading @ 25°C (77°F).

Area 5 + 5 areas (boxes and circles) with max./min./ average

Profile 1 line profile with max./min. temperature

Automatic hot/cold detection Auto hot or cold spotmeter markers within the area and profile

Measurement presets No measurements, Center spot, Hot spot, Cold spot, User preset 1, User preset 2

User presets The user can select and combine measurements from any number of spots/boxes/circles/profiles/ delta

Difference temperature Delta temperature between the measurement func- tions and the reference temperature

Show 5 more labels / short text on this page
Image presentation · Image presentation modes · Measurement · Measurement analysis · Spotmeter 10
Page 196 of the Flir T1020 user manual — 26.17 FLIR T1050sc 28°
Page 196 · click to enlarge
Page 196

Reference temperature Manually set using the difference temperature

Atmospheric transmission correction Automatic, based on the inputs for distance, at- mospheric temperature, and relative humidity

Optics transmission correction Automatic, based on signals from internal sensors

Emissivity correction Variable from 0.01 to 1.0 or selected from the ma- terials list

Reflected apparent temperature correction Automatic, based on the input of the reflected temperature

External optics/windows correction Automatic, based on the inputs of the window transmission and temperature

Measurement corrections Emissivity, reflected temperature, relative humidity, atmospheric temperature, object distance, external infrared window compensation

Colors (palettes) Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava

Color Alarm (isotherm) Above/below/interval

Measurement function alarm Audible/visual alarms (above/below) on any se- lected measurement function

Set-up commands Define user presets, Save options, Programmable button, Reset options, Set up camera, Wi-Fi, GPS & compass, Bluetooth, Language, Time & units, Camera information

Languages Arabic, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japa- nese, Korean, Norwegian, Polish, Portuguese, Russian, simplified Chinese, Swedish, traditional Chinese, Turkish

Camera software update Use PC software FLIR Tools

Image storage Standard JPEG, including digital image and meas- urement data, on a memory card

Storage media Removable media SD or SDHC card. Class 10 or better recommended

  • Image storage mode
  • Simultaneous storage of thermal and digital images in the same JPEG file
  • Option to store a digital photo as a separate JPEG file

Time lapse 15 seconds to 24 hours

  • File formats
  • Standard JPEG, measurement data included
  • CSQ, measurement data included

File formats, visual Standard JPEG, automatically associated with the corresponding thermal image

Show 5 more labels / short text on this page
Measurement analysis · Alarm · Set-up · Service functions · Storage of images
Page 197 of the Flir T1020 user manual — 26.17 FLIR T1050sc 28°
Page 197 · click to enlarge
Page 197

Voice 60 seconds (via Bluetooth) stored with the image

Text Add table, select between predefined templates

Image description Add short note (stored in the JPEG exif tag)

  • Sketch
  • Draw on the thermal/digital image or add predefined stamps
  • Separate PC software with extensive report generation

GPS Location data automatically added to every image from the built-in GPS

Compass Camera direction automatically added to every image

Video recording in camera

Radiometric IR-video recording Real-time radiometric recording (RTRR) to the memory card

Non-radiometric IR-video recording H.264 to the memory card

Visual video recording H.264 to the memory card

  • Radiometric IR-video streaming
  • Full dynamic un-compressed 120 Hz 16-bit full frame (2 Gbit) to a PC using an HSI box
  • Real-time radiometric streaming 30 Hz (RTRS) via USB
  • Non-radiometric IR-video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Visual video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Windowing
  • 30 Hz: 1024 × 768 (full image height)
  • Based on 30 Hz: 120 Hz windowing 1024 × 192 (¼ of full image height), for range –40 to +150°C (–40 to +302°F)
  • 120 Hz: 1024 × 768 (full image height)
  • Based on 120 Hz: 240 Hz windowing 1024 × 384 (½ of full image height), for range 0 to +650°C (+32 to +1202°F) and range +300 to +2000°C (+572 to +3632°F)

Digital camera Field of view adapts to the infrared lens

Video lamp Built-in LED light

Laser Activated by a dedicated button

Laser alignment Position is automatically displayed on the infrared image

Laser classification Class 2

Laser type Semiconductor AlGaInP diode laser, 1 mW, 635 nm (red)

Show 5 more labels / short text on this page
Image annotations · Geographic Information System · Video streaming · Digital camera · Laser pointer
Page 198 of the Flir T1020 user manual — USB
Page 198 · click to enlarge
Page 198

Interfaces USB Micro-B, Bluetooth, Wi-Fi, HDMI, USB3 Vi- sion via HSI box

Bluetooth Communication with a headset

Wi-Fi Infrastructure (network) or AP

SD Card One card slot for removable SD memory cards

Audio Microphone headset via Bluetooth for the voice an- notation of images

USB

USB USB Micro-Bdata transfer to and from a PC, uncompressed colorized video
  • USB, standard
  • USB 2.0 High Speed
  • USB Micro-B connector
  • USB3 Vision via HSI box
  • Video out
  • HDMI 640 × 480
  • HDMI 1280 × 720
  • DVI 640 × 480
  • DVI 800 × 600

Video, connector type HDMI type C

  • Wi-Fi
  • Standard: 802.11 b/g/n
  • Frequency range: 2412–2462 MHz
  • Max. output power: 15 dBm
Bluetooth Frequency range2402–2480 MHz, supports 2.1, 4.0, and 4.0 BLE

Battery type Rechargeable Li ion battery

Battery operating time >2.5 hours at 25°C (+68°F) and typical use

Charging system In camera (AC adapter or 12 V from a vehicle) or two-bay charger

Charging time 2.5 hours to 90% capacity, charging status indi- cated by LEDs

Charging temperature 0–45°C (32–113°F)

External power operation AC adapter 90–260 V AC, 50/60 Hz or 12 V from a vehicle (cable with a standard plug, optional)

Power management Automatic power-off functionality, user configura- ble between 5 minutes, 20 minutes, and no auto- matic shutdown

Operating temperature range –15°C to +50°C (+5°F to +122°F)

Storage temperature range –40 to +70°C (–40 to +158°F)

Humidity (operating and storage) IEC 60068-2-30 / 24 hours, 95% relative humidity, 25–40°C (77–104°F) / 2 cycles

Show 6 more labels / short text on this page
Data communication interfaces · Video · Radio · Antenna Internal · Power system · Environmental data
Page 199 of the Flir T1020 user manual — EAN-13 7332558010426
Page 199 · click to enlarge
Page 199
  • EMC
  • ETSI EN 301 489-1 (radio)
  • ETSI EN 301 489-17
  • EN 61000-6-2 (Immunity)
  • EN 61000-6-3 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
  • ICES-003
  • Radio spectrum
  • ETSI EN 300 328
  • FCC Part 15.247
  • RSS-247 issue 1

Encapsulation IP 54 (IEC 60529)

Shock 25 g (IEC 60068-2-29)

Vibration 2 g (IEC 60068-2-6)

Ergonomics The viewfinder plus the 120° rotating optical block allow you to point the camera in multiple directions while maintaining a comfortable position

Weight 1.9 kg (4.3 lb.)

Camera size, excl. lens (L × W × H) 167.2 mm × 204.5 mm × 188.3 mm (6.6 in. × 8.0 in. × 7.4 in.)

Tripod mounting UNC ¼"-20

  • Warranty
  • 2 years parts and labor coverage on the camera
  • 5 years coverage on the battery
  • 10 years coverage on the detector – the most vital part of the whole camera
  • List of contents
  • Infrared camera with lens
  • Battery (2 ea.)
  • Battery charger
  • Bluetooth headset
  • Calibration certificate
  • FLIR Tools+ license card
  • FLIR T10xx SC kit (in separate hard transport case):
  • High-speed interface
  • USB cable (USB 3), 3 m (10 ft.)
  • Digital I/O connector
  • FLIR ResearchIR Max license card
  • Printed documentation
  • Hard transport case
  • HDMI-HDMI cable
  • Lens cap
  • Memory card
  • Neck strap
  • Power supply, including multi-plugs
  • Printed documentation
  • USB cable, Std A to Micro-B

EAN-13 7332558010426

Show 6 more labels / short text on this page
Environmental data · Safety EN/UL/CSA/PSE 60950-1 · Physical data · Housing material Magnesium · Warranty information · Shipping information
Page 200 of the Flir T1020 user manual — Supplies & accessories
Page 200 · click to enlarge
Page 200

UPC-12 845188011079

Country of origin Sweden

Supplies & accessories

  • T199064; IR lens f=36mm (28°) with case
  • T199065; Close-up lens 3x (51 micron) with case
  • T199066; IR lens f=21.2mm (45°) with case
  • T199077; IR lens f=83.4mm (12°) with case
  • T910814; Power supply, incl. multi plugs
  • T198126; Battery charger, incl. power supply with multi plugs T6xx
  • T198506; Li-Ion Battery pack 3.7V 29Wh
  • T199406ACC; Battery Li-ion 3.7 V, 7.8 Ah, 29 Wh
  • T911230ACC; Memory card SDHC 4 GB
  • T198509; Cigarette lighter adapter kit, 12 VDC, 1.2 m/3.9 ft.
  • T910930ACC; HDMI type C to DVI cable 1.5 m
  • T910891ACC; HDMI type C to HDMI type A cable 1.5 m
  • 72500-0002; FLIR T10xx SC kit
  • T198497; Large eyecup
  • T197771ACC; Bluetooth Headset
  • T911093; Tool belt
  • T198533; USB cable Std A <-> Micro B
  • T198586; FLIR Reporter Professional (license only)
  • T198584; FLIR Tools
  • T198583; FLIR Tools+ (download card incl. license key)
  • DSW-10000; FLIR IR Camera Player
  • APP-10002; FLIR Tools Mobile (Android Application)
  • APP-10003; FLIR Tools Mobile (iPad/iPhone Application)
  • APP-10004; FLIR Tools (MacOS Application)
  • T198697; FLIR ResearchIR Max + HSDR 4 (hardware sec. dev.)
  • T199014; FLIR ResearchIR Max + HSDR 4 (printed license key)
  • T199044; FLIR ResearchIR Max + HSDR 4 Upgrade (printed license key)
  • T198696; FLIR ResearchIR Max 4 (hardware sec. dev.)
  • T199013; FLIR ResearchIR Max 4 (printed license key)
  • T199043; FLIR ResearchIR Max 4 Upgrade (printed license key)
  • T198731; FLIR ResearchIR Standard 4 (hardware sec. dev.)
  • T199012; FLIR ResearchIR Standard 4 (printed license key)
  • T199042; FLIR ResearchIR Standard 4 Upgrade (printed license key)
  • T199233; FLIR Atlas SDK for .NET
  • T199234; FLIR Atlas SDK for MATLAB

Shipping information

Page 201 of the Flir T1020 user manual — 26.18 FLIR T1050sc 45°
Page 201 · click to enlarge
Page 201

26.18 FLIR T1050sc 45°

P/N72501-0403 Rev.: 36741

The FLIR T1050sc is designed for the expert requiring the highest performance and the latest technology available. The camera combines excellent ergonomics and feature-rich flexibility with superior image quality at an infrared resolution of 1024 × 768 pixels. High accuracy and sensitivity together with radio- metric recording and streaming options make the FLIR T1050sc well suited for advanced research and development.

Benefits:

  • Tailor made for research and development: The FLIR T1050sc has high accuracy and high sensitivity, to accurately measure the smallest temperature differences. With real-time radiometric recording, it is possible to capture fast events on the camera’s SD card for further analysis by the supplied analysis software.
  • Flexible and feature rich: A wide variety of measuring and analysis functions make the FLIR T1050sc flexible for your every need. Two programmable buttons provide easy access to favorite functions.
  • Highest performance with the latest technology: The FLIR T1050sc is equipped with the innovative Multi Spectral Dynamic Imaging (MSX) feature, which produces an image richer in detail than ever before. With its continuous autofocus, the FLIR T1050sc is a fully automatic infrared camera.
  • Support for UltraMax: When enabling UltraMax in the camera, the resolution of images can be substantially enhanced when importing the images into FLIR Tools.

Imaging and optical data

IR resolution 1024 × 768 pixels

MSX resolution 1024 × 768 pixels

Thermal sensitivity/NETD

Field of view (FOV) 45° × 34°

Minimum IR focus distance 0.2 m (0.66 ft.)

Minimum IR–visual alignment distance 0.5 m (1.64 ft.)

Focal length 21.2 mm (0.83 in.)

Spatial resolution (IFOV) 0.80 mrad

F-number 1.1

Image frequency 30 Hz

Focus One shot or manual

Digital zoom 1–8× continuous

Digital image enhancement Adaptive digital noise reduction

Detector type Focal plane array (FPA), uncooled microbolometer

Spectral range 7.5–14 µm

Detector pitch 17 µm

Time constant < 10 ms

Display Built-in touch screen, 4.3 in. wide screen LCD, 800 × 480 pixels

Display type Capacitive touch screen

Show 5 more labels / short text on this page
General description · UltraMax Yes · Lens identification Automatic · Detector data · Image presentation
Page 202 of the Flir T1020 user manual — NOTE
Page 202 · click to enlarge
Page 202

Auto orientation Automatic landscape or portrait

Viewfinder Built-in 800 × 480 pixels

Automatic image adjustment Continuous, histogram based

Automatic image adjustment, type Standard or histogram based on the image content

Manual image adjustment Linear based, possible to adjust level/span/max./ min.

Image modes Thermal, thermal MSX, picture in picture, digital camera

Infrared image Full color infrared image

Visual image Full color visual image

Multi Spectral Dynamic Imaging (MSX) Thermal image with enhanced detail presentation

Picture in Picture Resizable and movable infrared area on the visual image

  • Gallery
  • Review thumbnail/full image on the camera
  • Edit measurements/palettes/image modes on the camera
  • Object temperature range
  • –40 to +150°C (–40 to +302°F)
  • 0 to +650°C (+32 to +1202°F)
  • +300 to +2000°C (+572 to +3632°F)
  • Accuracy
  • ±1°C (±1.8°F) or ±1% @ 25°C (77°F) for temperatures between 5 and 150°C (41 and 302° F), in range –40 to 150°C (–40 to 302°F)
  • ±2°C (±3.6°F) or ±2% of reading @ 25°C (77° F) for temperatures between –40 and 2000°C (–40 and 3632°F)

NOTE

For HSI (high-speed interface) use, above 30 Hz frame rate, the typical accuracy will be ±2.5° C (±4.5°F), or 2.5% of reading @ 25°C (77°F).

Area 5 + 5 areas (boxes and circles) with max./min./ average

Profile 1 line profile with max./min. temperature

Automatic hot/cold detection Auto hot or cold spotmeter markers within the area and profile

Measurement presets No measurements, Center spot, Hot spot, Cold spot, User preset 1, User preset 2

User presets The user can select and combine measurements from any number of spots/boxes/circles/profiles/ delta

Difference temperature Delta temperature between the measurement func- tions and the reference temperature

Show 5 more labels / short text on this page
Image presentation · Image presentation modes · Measurement · Measurement analysis · Spotmeter 10
Page 203 of the Flir T1020 user manual — 26.18 FLIR T1050sc 45°
Page 203 · click to enlarge
Page 203

Reference temperature Manually set using the difference temperature

Atmospheric transmission correction Automatic, based on the inputs for distance, at- mospheric temperature, and relative humidity

Optics transmission correction Automatic, based on signals from internal sensors

Emissivity correction Variable from 0.01 to 1.0 or selected from the ma- terials list

Reflected apparent temperature correction Automatic, based on the input of the reflected temperature

External optics/windows correction Automatic, based on the inputs of the window transmission and temperature

Measurement corrections Emissivity, reflected temperature, relative humidity, atmospheric temperature, object distance, external infrared window compensation

Colors (palettes) Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava

Color Alarm (isotherm) Above/below/interval

Measurement function alarm Audible/visual alarms (above/below) on any se- lected measurement function

Set-up commands Define user presets, Save options, Programmable button, Reset options, Set up camera, Wi-Fi, GPS & compass, Bluetooth, Language, Time & units, Camera information

Languages Arabic, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japa- nese, Korean, Norwegian, Polish, Portuguese, Russian, simplified Chinese, Swedish, traditional Chinese, Turkish

Camera software update Use PC software FLIR Tools

Image storage Standard JPEG, including digital image and meas- urement data, on a memory card

Storage media Removable media SD or SDHC card. Class 10 or better recommended

  • Image storage mode
  • Simultaneous storage of thermal and digital images in the same JPEG file
  • Option to store a digital photo as a separate JPEG file

Time lapse 15 seconds to 24 hours

  • File formats
  • Standard JPEG, measurement data included
  • CSQ, measurement data included

File formats, visual Standard JPEG, automatically associated with the corresponding thermal image

Show 5 more labels / short text on this page
Measurement analysis · Alarm · Set-up · Service functions · Storage of images
Page 204 of the Flir T1020 user manual — 26.18 FLIR T1050sc 45°
Page 204 · click to enlarge
Page 204

Voice 60 seconds (via Bluetooth) stored with the image

Text Add table, select between predefined templates

Image description Add short note (stored in the JPEG exif tag)

  • Sketch
  • Draw on the thermal/digital image or add predefined stamps
  • Separate PC software with extensive report generation

GPS Location data automatically added to every image from the built-in GPS

Compass Camera direction automatically added to every image

Video recording in camera

Radiometric IR-video recording Real-time radiometric recording (RTRR) to the memory card

Non-radiometric IR-video recording H.264 to the memory card

Visual video recording H.264 to the memory card

  • Radiometric IR-video streaming
  • Full dynamic un-compressed 120 Hz 16-bit full frame (2 Gbit) to a PC using an HSI box
  • Real-time radiometric streaming 30 Hz (RTRS) via USB
  • Non-radiometric IR-video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Visual video streaming
  • H.264 video using Wi-Fi
  • H.264 video using USB
  • Windowing
  • 30 Hz: 1024 × 768 (full image height)
  • Based on 30 Hz: 120 Hz windowing 1024 × 192 (¼ of full image height), for range –40 to +150°C (–40 to +302°F)
  • 120 Hz: 1024 × 768 (full image height)
  • Based on 120 Hz: 240 Hz windowing 1024 × 384 (½ of full image height), for range 0 to +650°C (+32 to +1202°F) and range +300 to +2000°C (+572 to +3632°F)

Digital camera Field of view adapts to the infrared lens

Video lamp Built-in LED light

Laser Activated by a dedicated button

Laser alignment Position is automatically displayed on the infrared image

Laser classification Class 2

Laser type Semiconductor AlGaInP diode laser, 1 mW, 635 nm (red)

Show 5 more labels / short text on this page
Image annotations · Geographic Information System · Video streaming · Digital camera · Laser pointer
Page 205 of the Flir T1020 user manual — USB
Page 205 · click to enlarge
Page 205

Interfaces USB Micro-B, Bluetooth, Wi-Fi, HDMI, USB3 Vi- sion via HSI box

Bluetooth Communication with a headset

Wi-Fi Infrastructure (network) or AP

SD Card One card slot for removable SD memory cards

Audio Microphone headset via Bluetooth for the voice an- notation of images

USB

USB USB Micro-Bdata transfer to and from a PC, uncompressed colorized video
  • USB, standard
  • USB 2.0 High Speed
  • USB Micro-B connector
  • USB3 Vision via HSI box
  • Video out
  • HDMI 640 × 480
  • HDMI 1280 × 720
  • DVI 640 × 480
  • DVI 800 × 600

Video, connector type HDMI type C

  • Wi-Fi
  • Standard: 802.11 b/g/n
  • Frequency range: 2412–2462 MHz
  • Max. output power: 15 dBm
Bluetooth Frequency range2402–2480 MHz, supports 2.1, 4.0, and 4.0 BLE

Battery type Rechargeable Li ion battery

Battery operating time >2.5 hours at 25°C (+68°F) and typical use

Charging system In camera (AC adapter or 12 V from a vehicle) or two-bay charger

Charging time 2.5 hours to 90% capacity, charging status indi- cated by LEDs

Charging temperature 0–45°C (32–113°F)

External power operation AC adapter 90–260 V AC, 50/60 Hz or 12 V from a vehicle (cable with a standard plug, optional)

Power management Automatic power-off functionality, user configura- ble between 5 minutes, 20 minutes, and no auto- matic shutdown

Operating temperature range –15°C to +50°C (+5°F to +122°F)

Storage temperature range –40 to +70°C (–40 to +158°F)

Humidity (operating and storage) IEC 60068-2-30 / 24 hours, 95% relative humidity, 25–40°C (77–104°F) / 2 cycles

Show 6 more labels / short text on this page
Data communication interfaces · Video · Radio · Antenna Internal · Power system · Environmental data
Page 206 of the Flir T1020 user manual — EAN-13 7332558010433
Page 206 · click to enlarge
Page 206
  • EMC
  • ETSI EN 301 489-1 (radio)
  • ETSI EN 301 489-17
  • EN 61000-6-2 (Immunity)
  • EN 61000-6-3 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
  • ICES-003
  • Radio spectrum
  • ETSI EN 300 328
  • FCC Part 15.247
  • RSS-247 issue 1

Encapsulation IP 54 (IEC 60529)

Shock 25 g (IEC 60068-2-29)

Vibration 2 g (IEC 60068-2-6)

Ergonomics The viewfinder plus the 120° rotating optical block allow you to point the camera in multiple directions while maintaining a comfortable position

Weight 2.0 kg (4.3 lb.)

Camera size, excl. lens (L × W × H) 167.2 mm × 204.5 mm × 188.3 mm (6.6 in. × 8.0 in. × 7.4 in.)

Tripod mounting UNC ¼"-20

  • Warranty
  • 2 years parts and labor coverage on the camera
  • 5 years coverage on the battery
  • 10 years coverage on the detector – the most vital part of the whole camera
  • List of contents
  • Infrared camera with lens
  • Battery (2 ea.)
  • Battery charger
  • Bluetooth headset
  • Calibration certificate
  • FLIR Tools+ license card
  • FLIR T10xx SC kit (in separate hard transport case):
  • High-speed interface
  • USB cable (USB 3), 3 m (10 ft.)
  • Digital I/O connector
  • FLIR ResearchIR Max license card
  • Printed documentation
  • Hard transport case
  • HDMI-HDMI cable
  • Lens cap
  • Memory card
  • Neck strap
  • Power supply, including multi-plugs
  • Printed documentation
  • USB cable, Std A to Micro-B

EAN-13 7332558010433

Show 6 more labels / short text on this page
Environmental data · Safety EN/UL/CSA/PSE 60950-1 · Physical data · Housing material Magnesium · Warranty information · Shipping information
Page 207 of the Flir T1020 user manual — Supplies & accessories
Page 207 · click to enlarge
Page 207

UPC-12 845188011086

Country of origin Sweden

Supplies & accessories

  • T199064; IR lens f=36mm (28°) with case
  • T199065; Close-up lens 3x (51 micron) with case
  • T199066; IR lens f=21.2mm (45°) with case
  • T199077; IR lens f=83.4mm (12°) with case
  • T910814; Power supply, incl. multi plugs
  • T198126; Battery charger, incl. power supply with multi plugs T6xx
  • T198506; Li-Ion Battery pack 3.7V 29Wh
  • T199406ACC; Battery Li-ion 3.7 V, 7.8 Ah, 29 Wh
  • T911230ACC; Memory card SDHC 4 GB
  • T198509; Cigarette lighter adapter kit, 12 VDC, 1.2 m/3.9 ft.
  • T910930ACC; HDMI type C to DVI cable 1.5 m
  • T910891ACC; HDMI type C to HDMI type A cable 1.5 m
  • 72500-0002; FLIR T10xx SC kit
  • T198497; Large eyecup
  • T197771ACC; Bluetooth Headset
  • T911093; Tool belt
  • T198533; USB cable Std A <-> Micro B
  • T198586; FLIR Reporter Professional (license only)
  • T198584; FLIR Tools
  • T198583; FLIR Tools+ (download card incl. license key)
  • DSW-10000; FLIR IR Camera Player
  • APP-10002; FLIR Tools Mobile (Android Application)
  • APP-10003; FLIR Tools Mobile (iPad/iPhone Application)
  • APP-10004; FLIR Tools (MacOS Application)
  • T198697; FLIR ResearchIR Max + HSDR 4 (hardware sec. dev.)
  • T199014; FLIR ResearchIR Max + HSDR 4 (printed license key)
  • T199044; FLIR ResearchIR Max + HSDR 4 Upgrade (printed license key)
  • T198696; FLIR ResearchIR Max 4 (hardware sec. dev.)
  • T199013; FLIR ResearchIR Max 4 (printed license key)
  • T199043; FLIR ResearchIR Max 4 Upgrade (printed license key)
  • T198731; FLIR ResearchIR Standard 4 (hardware sec. dev.)
  • T199012; FLIR ResearchIR Standard 4 (printed license key)
  • T199042; FLIR ResearchIR Standard 4 Upgrade (printed license key)
  • T199233; FLIR Atlas SDK for .NET
  • T199234; FLIR Atlas SDK for MATLAB

Shipping information

Page 208 of the Flir T1020 user manual — Compatible with the following products
Page 208 · click to enlarge
Page 208

26.19 IR lens, f=36 mm (28°) with case

P/NT199064 Rev.: 30226

The standard 28° lens is suitable for the majority of applications.

Imaging and optical data

Field of view (FOV) 28° × 21° (34.5° diagonal)

Minimum focus distance 0.4 m (1.32 ft.)

Focal length 36 mm (1.42 in.)

Spatial resolution (IFOV) 0.47 mrad

F-number 1.15

Number of lenses 4 (4 asph)

Distortion 2.8%

Weight 0.730 kg (1.61 lb.)

Size (L × D) 93.4 × 91 mm (3.68 × 3.58 in.)

Front lens diameter 64 mm (2.5 in.)

Packaging, type Cardboard box

  • List of contents
  • Lens
  • Lens case
  • Front lens cap
  • Rear lens cap
  • Mounting instruction

Packaging, weight 1.1 kg (2.4 lb.)

Packaging, size 173 × 135 × 135 mm (6.81 × 5.31 × 5.31 in.)

EAN-13 7332558010983

UPC-12 845188011833

Country of origin Sweden

Compatible with the following products

  • 72501-0101; FLIR T1020 12°
  • 72501-0102; FLIR T1020 28°
  • 72501-0103; FLIR T1020 45°
  • 72501-0104; FLIR T1020 28° and 12°
  • 72501-0105; FLIR T1020 28° and 45°
  • 72501-0106; FLIR T1020 28°, 12°, and 45°
  • 72501-0201; FLIR T1030sc 12°
  • 72501-0202; FLIR T1030sc 28°
  • 72501-0203; FLIR T1030sc 45°
  • 72501-0301; FLIR T1040 12°
  • 72501-0302; FLIR T1040 28°
  • 72501-0303; FLIR T1040 45°
  • 72501-0401; FLIR T1050sc 12°
Show 4 more labels / short text on this page
General description · Lens identification Automatic · Physical data · Shipping information
Page 209 of the Flir T1020 user manual — 26.19 IR lens, f=36 mm (28°) with case
Page 209 · click to enlarge
Page 209
  • 72501-0402; FLIR T1050sc 28°
  • 72501-0403; FLIR T1050sc 45°
Page 210 of the Flir T1020 user manual — Compatible with the following products:
Page 210 · click to enlarge
Page 210

26.20 Close-up lens 3× (51 µm) with case

P/NT199065 Rev.: 30226
Flir T1020 — 26.20 Close-up lens 3× (51 µm) with case diagram (page 210)
Fig. 76 · 26.20 Close-up lens 3× (51 µm) with case

The close-up lens is attached to the standard 28° IR lens and provides three times magnification. The close-up lens is intended for R&D usage or development purposes. As an example, for studies of PCBs and small electronic components.

Field of view (FOV) 52° × 40° (66° diagonal)

Size (L × D) 127.5 × 91 mm (5.02 × 3.58 in.)

  • List of contents
  • Lens
  • Lens case
  • Front lens cap
  • Rear lens cap
  • Mounting instruction

Packaging, size 173 × 135 × 135 mm (6.81 × 5.31 × 5.31 in.)

Compatible with the following products:

  • 72501-0201; FLIR T1030sc 12°
  • 72501-0202; FLIR T1030sc 28°
  • 72501-0203; FLIR T1030sc 45°
  • 72501-0401; FLIR T1050sc 12°
  • 72501-0402; FLIR T1050sc 28°
  • 72501-0403; FLIR T1050sc 45°
Page 211 of the Flir T1020 user manual — Compatible with the following products
Page 211 · click to enlarge
Page 211

26.21 IR lens f=21.2 mm (45°) with case

P/NT199066 Rev.: 30226

The 45° has a field of view approximately two times that of the standard 28° lens. This wide angle lens is suitable for cramped situations where the operator cannot step farther back from the object.

Imaging and optical data

Field of view (FOV) 45° × 34° (55.2° diagonal)

Minimum focus distance 0.2 m (0.66 ft.)

Focal length 21.2 mm (0.83 in.)

Spatial resolution (IFOV) 0.80 mrad

F-number 1.1

Number of lenses 4 (4 asph)

Distortion 1.71%

Weight 0.754 kg (1.66 lb.)

Size (L × D) 96.9 × 91 mm (3.82 × 3.58 in.)

Front lens diameter 59 mm (2.3 in.)

Packaging, type Cardboard box

  • List of contents
  • Lens
  • Lens case
  • Front lens cap
  • Rear lens cap
  • Mounting instruction

Packaging, weight 1.1 kg (2.4 lb.)

Packaging, size 173 × 135 × 135 mm (6.81 × 5.31 × 5.31 in.)

EAN-13 7332558010990

UPC-12 845188011840

Country of origin Sweden

Compatible with the following products

  • 72501-0101; FLIR T1020 12°
  • 72501-0102; FLIR T1020 28°
  • 72501-0103; FLIR T1020 45°
  • 72501-0104; FLIR T1020 28° and 12°
  • 72501-0105; FLIR T1020 28° and 45°
  • 72501-0106; FLIR T1020 28°, 12°, and 45°
  • 72501-0201; FLIR T1030sc 12°
  • 72501-0202; FLIR T1030sc 28°
  • 72501-0203; FLIR T1030sc 45°
  • 72501-0301; FLIR T1040 12°
  • 72501-0302; FLIR T1040 28°
  • 72501-0303; FLIR T1040 45°
Show 4 more labels / short text on this page
General description · Lens identification Automatic · Physical data · Shipping information
Page 212 of the Flir T1020 user manual — 26.21 IR lens f=21.2 mm (45°) with case
Page 212 · click to enlarge
Page 212
  • 72501-0401; FLIR T1050sc 12°
  • 72501-0402; FLIR T1050sc 28°
  • 72501-0403; FLIR T1050sc 45°
Page 213 of the Flir T1020 user manual — Compatible with the following products
Page 213 · click to enlarge
Page 213

26.22 IR lens f=83.4 mm (12°) with case

P/NT199077 Rev.: 30226

The 12° lens provides approximately two times magnification compared to the standard 28° lens. This lens is ideal for small or distant targets, such as overhead power lines.

Imaging and optical data

Field of view (FOV) 12° × 9° ( 15.2° diagonal)

Minimum focus distance 0.8 m (2.63 ft.)

Focal length 83.4 mm (3.28 in.)

Spatial resolution (IFOV) 0.20 mrad

F-number 1.2

Number of lenses 5 (5 asph)

Distortion 2.2%

Weight 1.06 kg (2.34 lb.)

Size (L × D) 134.1 × 100.5 mm (5.28 × 3.96 in.)

Front lens diameter 75 mm (3.0 in.)

Packaging, type Cardboard box

  • List of contents
  • Lens
  • Lens case
  • Front lens cap
  • Rear lens cap
  • Mounting instruction

Packaging, weight 1.4 kg (3.1 lb.)

Packaging, size 212 × 150 × 150 mm (8.35 × 5.91 × 5.91 in.)

EAN-13 7332558011010

UPC-12 845188011864

Country of origin Sweden

Compatible with the following products

  • 72501-0101; FLIR T1020 12°
  • 72501-0102; FLIR T1020 28°
  • 72501-0103; FLIR T1020 45°
  • 72501-0104; FLIR T1020 28° and 12°
  • 72501-0105; FLIR T1020 28° and 45°
  • 72501-0106; FLIR T1020 28°, 12°, and 45°
  • 72501-0201; FLIR T1030sc 12°
  • 72501-0202; FLIR T1030sc 28°
  • 72501-0203; FLIR T1030sc 45°
  • 72501-0301; FLIR T1040 12°
  • 72501-0302; FLIR T1040 28°
  • 72501-0303; FLIR T1040 45°
Show 4 more labels / short text on this page
General description · Lens identification Automatic · Physical data · Shipping information
Page 214 of the Flir T1020 user manual — 26.22 IR lens f=83.4 mm (12°) with case
Page 214 · click to enlarge
Page 214
  • 72501-0401; FLIR T1050sc 12°
  • 72501-0402; FLIR T1050sc 28°
  • 72501-0403; FLIR T1050sc 45°
Page 215 of the Flir T1020 user manual — EAN-13 7332558011041
Page 215 · click to enlarge
Page 215

26.23 FLIR T10xx SC kit

P/N72500-0002 Rev.: 36742

The FLIR T10xx SC kit is intended for R&D usage and development purposes. The kit includes a high- speed interface (HSI) box, which enables streaming of fully radiometric and uncompressed video from a FLIR T10xx series camera to a PC running the FLIR ResearchIR Max software.

  • Interfaces
  • USB 3 Vision
  • Digital I/O
  • Proprietary FLIR interface
  • Image streaming
  • Up to 120 Hz full frame
  • Up to 240 Hz by windowing
  • Image formats
  • Unfiltred, uncompressed 14 bit radiometric raw data
  • Lossless, maximal sensitivity

Electronics and data rate

  • Windowing
  • 30 Hz: 1024 × 768 (full image height)
  • Based on 30 Hz: 120 Hz windowing 1024 × 192 (¼ of full image height), for range –40 to +150°C (–40 to +302°F)
  • 120 Hz: 1024 × 768 (full image height)
  • Based on 120 Hz: 240 Hz windowing 1024 × 384 (½ of full image height), for range 0 to +650°C (+32 to +1202°F) and range +300 to +2000°C (+572 to +3632°F)

Power, HSI box Powered from PC via USB 3

Weight, HSI box 0.405 kg (0.893 lb.)

Weight, USB cable 0.135 kg (0.298 lb.)

Size (L × W × H), HSI box 125 × 72.4× 56.7 mm (4.92 × 2.85 × 2.23 in.)

Mounting, HSI box Tripod mount, velcro straps

Packaging, type Cardboard box

  • List of contents
  • High-speed interface
  • Hard transport case
  • USB cable (USB 3), 3 m (10 ft.)
  • Digital I/O connector
  • FLIR ResearchIR Max license card
  • Printed documentation

Packaging, weight 2.1 kg (4.6 lb.)

Packaging, size 303 × 206 × 128 mm (11.9 × 18.1 × 5.0 in.)

EAN-13 7332558011041

Show 6 more labels / short text on this page
General description · Communication · Video streaming · Power system · Physical data · Shipping information
Page 216 of the Flir T1020 user manual — UPC-12 845188011888
Page 216 · click to enlarge
Page 216

UPC-12 845188011888

Country of origin Sweden

  • 72501-0201; FLIR T1030sc 12°
  • 72501-0202; FLIR T1030sc 28°
  • 72501-0203; FLIR T1030sc 45°
  • 72501-0401; FLIR T1050sc 12°
  • 72501-0402; FLIR T1050sc 28°
  • 72501-0403; FLIR T1050sc 45°

Shipping information

Page 217 of the Flir T1020 user manual — Mechanical drawings 27
Page 217 · click to enlarge
Page 217

Mechanical drawings 27

Page 218 of the Flir T1020 user manual — A
Page 218 · click to enlarge
Page 218

A

B

D

E

F

G

D

T128849

1 2 3 4 5 6 7 8 9 10

Drawing No.

1:2

1,75in 44,5mm 0,55in 14mm

1,72in 43,7mm 2,3in 58,4mm

Flir T1020 — A diagram (page 218)
Fig. 77
Flir T1020 — A diagram (page 218)
Fig. 78

JOTA 2015-09-17 R&D Thermography

1,74in 44,3mm 6,31in 160,2mm

Basic dimensions FLIR T10xx

Flir T1020 — A diagram (page 218)
Fig. 79

1 3 2 5 4

Flir T1020 — A diagram (page 218)
Fig. 80

Camera housing

A

B

D

E

F

G

H

© 2012, FLIR Systems, Inc. All rights reserved worldwide. No part of this drawing may be reproduced, stored in a retrieval system, or transmitted in any form, or by any means, electronic, mechanical, photocopying, recording, or otherwise, without written permission from FLIR Systems, Inc. Specifications subject to change without further notice. Dimensional data is based on nominal values. Products may be subject to regional market considerations. License procedures may apply. Product may be subject to US Export Regulations. Please refer to exportquestions@flir.com with any questions. Diversion contrary to US law is prohibited.

Show 25 more labels / short text on this page
1(7) · Sheet · Size · 7,41in 188,3mm · 4,55in 115,5mm · 5,63in 143mm · Denomination A3 · Scale · Size · 2,77in 70,4mm · Check Drawn by · 8,05in 204,5mm · Modified · Viewfinder · Optional · 5,37in 136,3mm · 5,67in 144mm · 4,76in 120,8mm · 4,55in 115,5mm · 7,41in 188,3mm · 7,1in 180,4mm · 2,68in 68mm · 6,58in 167,2mm · 5,63in 142,9mm · 1,72in 43,7mm
Page 219 of the Flir T1020 user manual — A
Page 219 · click to enlarge
Page 219

A

B

D

E

F

G

D

T128849

1 2 3 4 5 6 7 8 9 10

Drawing No.

1:2

Flir T1020 — A diagram (page 219)
Fig. 81

JOTA 2015-09-17 R&D Thermography

Basic dimensions FLIR T10xx

Flir T1020 — A diagram (page 219)
Fig. 82
Flir T1020 — A diagram (page 219)
Fig. 83

1 3 2 5 4

Flir T1020 — A diagram (page 219)
Fig. 84

IR-LENS 12° (f=83,4mm)

A

B

D

E

F

G

H

© 2012, FLIR Systems, Inc. All rights reserved worldwide. No part of this drawing may be reproduced, stored in a retrieval system, or transmitted in any form, or by any means, electronic, mechanical, photocopying, recording, or otherwise, without written permission from FLIR Systems, Inc. Specifications subject to change without further notice. Dimensional data is based on nominal values. Products may be subject to regional market considerations. License procedures may apply. Product may be subject to US Export Regulations. Please refer to exportquestions@flir.com with any questions. Diversion contrary to US law is prohibited.

Show 17 more labels / short text on this page
2(7) · Sheet · Size · 5,9in 149,9mm · Denomination A3 · Scale · Size · 3,96in 100,5mm · Check Drawn by · 7,67in 194,9mm · Modified · 8,29in 210,4mm · 5,02in 127,4mm · 8,63in 219,2mm · 7,67in 194,9mm · 5,19in 131,9mm · 5,28in 134,1mm
Page 220 of the Flir T1020 user manual — A
Page 220 · click to enlarge
Page 220

A

B

D

E

F

G

D

T128849

1 2 3 4 5 6 7 8 9 10

Drawing No.

1:2

Flir T1020 — A diagram (page 220)
Fig. 85

JOTA 2015-09-17 R&D Thermography

Basic dimensions FLIR T10xx

4,83in 122,6mm 3,58in 91mm

Flir T1020 — A diagram (page 220)
Fig. 86
Flir T1020 — A diagram (page 220)
Fig. 87

1 3 2 5 4

Flir T1020 — A diagram (page 220)
Fig. 88

IR-LENS 28° (f=36mm)

A

B

D

E

F

G

H

© 2012, FLIR Systems, Inc. All rights reserved worldwide. No part of this drawing may be reproduced, stored in a retrieval system, or transmitted in any form, or by any means, electronic, mechanical, photocopying, recording, or otherwise, without written permission from FLIR Systems, Inc. Specifications subject to change without further notice. Dimensional data is based on nominal values. Products may be subject to regional market considerations. License procedures may apply. Product may be subject to US Export Regulations. Please refer to exportquestions@flir.com with any questions. Diversion contrary to US law is prohibited.

Show 15 more labels / short text on this page
3(7) · Sheet · Size · Denomination A3 · 4,32in 109,8mm · Scale · Size · Check Drawn by · 7,49in 190,1mm · Modified · 8,1in 205,7mm · 7,03in 178,5mm · 6,07in 154,2mm · 3,59in 91,2mm · 3,68in 93,4mm
Page 221 of the Flir T1020 user manual — A
Page 221 · click to enlarge
Page 221

A

B

D

E

F

G

D

T128849

1 2 3 4 5 6 7 8 9 10

Drawing No.

1:2

Flir T1020 — A diagram (page 221)
Fig. 89

JOTA 2015-09-17 R&D Thermography

Basic dimensions FLIR T10xx

4,83in 122,6mm 3,58in 91mm

Flir T1020 — A diagram (page 221)
Fig. 90
Flir T1020 — A diagram (page 221)
Fig. 91

1 3 2 5 4

Flir T1020 — A diagram (page 221)
Fig. 92

IR-LENS 45° (f=21,2mm)

A

B

D

E

F

G

H

© 2012, FLIR Systems, Inc. All rights reserved worldwide. No part of this drawing may be reproduced, stored in a retrieval system, or transmitted in any form, or by any means, electronic, mechanical, photocopying, recording, or otherwise, without written permission from FLIR Systems, Inc. Specifications subject to change without further notice. Dimensional data is based on nominal values. Products may be subject to regional market considerations. License procedures may apply. Product may be subject to US Export Regulations. Please refer to exportquestions@flir.com with any questions. Diversion contrary to US law is prohibited.

Show 15 more labels / short text on this page
4(7) · Sheet · Size · Denomination A3 · 4,46in 113,3mm · Scale · Size · Check Drawn by · 7,49in 190,1mm · Modified · 8,1in 205,7mm · 7,17in 182,1mm · 6,21in 157,8mm · 3,73in 94,8mm · 3,82in 96,9mm
Page 222 of the Flir T1020 user manual — A
Page 222 · click to enlarge
Page 222

A

B

D

E

F

G

D

T128849

1 2 3 4 5 6 7 8 9 10

Drawing No.

1:2

Flir T1020 — A diagram (page 222)
Fig. 93

JOTA 2015-09-17 R&D Thermography

Basic dimensions FLIR T10xx

Flir T1020 — A diagram (page 222)
Fig. 94

8,37in 212,6mm 8,1in 205,7mm

Flir T1020 — A diagram (page 222)
Fig. 95

1 3 2 5 4

Flir T1020 — A diagram (page 222)
Fig. 96

IR-LENS CLOSE-UP (3X)

A

B

D

E

F

G

H

© 2012, FLIR Systems, Inc. All rights reserved worldwide. No part of this drawing may be reproduced, stored in a retrieval system, or transmitted in any form, or by any means, electronic, mechanical, photocopying, recording, or otherwise, without written permission from FLIR Systems, Inc. Specifications subject to change without further notice. Dimensional data is based on nominal values. Products may be subject to regional market considerations. License procedures may apply. Product may be subject to US Export Regulations. Please refer to exportquestions@flir.com with any questions. Diversion contrary to US law is prohibited.

Show 15 more labels / short text on this page
5(7) · Sheet · Size · Denomination A3 · 5,67in 143,9mm · Scale · Size · 3,58in 91mm · Check Drawn by · 7,49in 190,1mm · Modified · 4,83in 122,7mm · 7,42in 188,4mm · 4,94in 125,4mm · 5,02in 127,5mm
Page 223 of the Flir T1020 user manual — A
Page 223 · click to enlarge
Page 223

A

B

D

E

F

G

D

T128849

1 2 3 4 5 6 7 8 9 10

Drawing No.

1:2

JOTA 2015-09-17 R&D Thermography

Basic dimensions FLIR T10xx

1 3 2 5 4

Battery Charger

A

B

D

E

F

G

H

© 2012, FLIR Systems, Inc. All rights reserved worldwide. No part of this drawing may be reproduced, stored in a retrieval system, or transmitted in any form, or by any means, electronic, mechanical, photocopying, recording, or otherwise, without written permission from FLIR Systems, Inc. Specifications subject to change without further notice. Dimensional data is based on nominal values. Products may be subject to regional market considerations. License procedures may apply. Product may be subject to US Export Regulations. Please refer to exportquestions@flir.com with any questions. Diversion contrary to US law is prohibited.

Show 15 more labels / short text on this page
6(7) · Sheet · Size · Denomination A3 · Scale · Size · 3,3in 83,8mm · 1,57in 39,8mm · Check Drawn by · 1,47in 37,3mm · Modified · 2,01in 51mm · 5,25in 133,2mm · 3,85in 97,7mm · 3,4in 86,4mm
Page 224 of the Flir T1020 user manual — A
Page 224 · click to enlarge
Page 224

A

B

D

E

F

G

D

T128849

1 2 3 4 5 6 7 8 9 10

Drawing No.

1:2

JOTA 2015-09-17 R&D Thermography

Basic dimensions FLIR T10xx

4,92in 125mm [14,2in 2]

1 3 2 5 4

UNC 1/4-20 7mm 0,28in

High-Speed Interface

A

B

D

E

F

G

H

© 2012, FLIR Systems, Inc. All rights reserved worldwide. No part of this drawing may be reproduced, stored in a retrieval system, or transmitted in any form, or by any means, electronic, mechanical, photocopying, recording, or otherwise, without written permission from FLIR Systems, Inc. Specifications subject to change without further notice. Dimensional data is based on nominal values. Products may be subject to regional market considerations. License procedures may apply. Product may be subject to US Export Regulations. Please refer to exportquestions@flir.com with any questions. Diversion contrary to US law is prohibited.

Show 12 more labels / short text on this page
7(7) · Sheet · Size · Denomination A3 · Scale · Size · Check Drawn by · Modified · 360mm 50 · 1,1in 28mm · 2,85in 72,4mm · 2,23in 56,7mm
Page 225 of the Flir T1020 user manual — 28.1 Pin configuration for the Digital I/O connector on the HSI box
Page 225 · click to enlarge
Page 225

Digital I/O pin configuration 28

28.1 Pin configuration for the Digital I/O connector on the HSI box

1 IN 1 opto-isolated, 0–1.5 V = low, 3– 25 V = high

2 IN 2 opto-isolated, 0–1.5 V = low, 3– 25 V = high

3 OUT 1 opto-isolated, ON = supply (max. 100 mA), OFF = open

4 OUT 2 opto-isolated, ON = supply (max. 100 mA), OFF = open

5 Supply VCC 6–24 VDC, max. 200 mA

6 Supply Gnd Gnd

Pin Function Data

Page 226 of the Flir T1020 user manual — Digital I/O connection diagram 29
Page 226 · click to enlarge
Page 226

Digital I/O connection diagram 29

Page 227 of the Flir T1020 user manual — 29 Digital I/O connection diagram
Page 227 · click to enlarge
Page 227
Flir T1020 — 29 Digital I/O connection diagram diagram (page 227)
Fig. 97 · 29 Digital I/O connection diagram
Page 228 of the Flir T1020 user manual — CE Declaration of conformity 30
Page 228 · click to enlarge
Page 228

CE Declaration of conformity 30

Page 229 of the Flir T1020 user manual — 30 CE Declaration of conformity
Page 229 · click to enlarge
Page 229
Flir T1020 — 30 CE Declaration of conformity diagram (page 229)
Fig. 98 · 30 CE Declaration of conformity
Page 230 of the Flir T1020 user manual — CAUTION
Page 230 · click to enlarge
Page 230

Cleaning the camera 31

31.1 Camera housing, cables, and other items

31.1.1 Liquids

Use one of these liquids:

  • Warm water
  • A weak detergent solution

31.1.2 Equipment

31.1.3 Procedure

Follow this procedure:

1. Soak the cloth in the liquid. 2. Twist the cloth to remove excess liquid. 3. Clean the part with the cloth.

CAUTION

Do not apply solvents or similar liquids to the camera, the cables, or other items. This can cause damage.

31.2 Infrared lens

31.2.1 Liquids

Use one of these liquids:

  • A commercial lens cleaning liquid with more than 30% isopropyl alcohol.
  • 96% ethyl alcohol (C 2 H 5 OH).

31.2.2 Equipment

31.2.3 Procedure

Follow this procedure:

1. Soak the cotton wool in the liquid. 2. Twist the cotton wool to remove excess liquid. 3. Clean the lens one time only and discard the cotton wool.

WARNING

Make sure that you read all applicable MSDS (Material Safety Data Sheets) and warning labels on con- tainers before you use a liquid: the liquids can be dangerous.

CAUTION

  • Be careful when you clean the infrared lens. The lens has a delicate anti-reflective coating.
  • Do not clean the infrared lens too vigorously. This can damage the anti-reflective coating.

A soft cloth · Cotton wool

Page 231 of the Flir T1020 user manual — 31.3.2 Procedure
Page 231 · click to enlarge
Page 231

Cleaning the camera 31

31.3 Infrared detector

31.3.1 General

Even small amounts of dust on the infrared detector can result in major blemishes in the image. To remove any dust from the detector, follow the procedure below.

Note

  • This section only applies to cameras where removing the lens exposes the infrared detector.
  • In some cases the dust cannot be removed by following this procedure: the infrared detector must be cleaned mechanically. This mechanical cleaning must be carried out by an authorized service partner.

CAUTION

In Step 2 below, do not use pressurized air from pneumatic air circuits in a workshop, etc., as this air usu- ally contains oil mist to lubricate pneumatic tools.

31.3.2 Procedure

Follow this procedure:

1. Remove the lens from the camera. 2. Use pressurized air from a compressed air canister to blow off the dust.
Page 232 of the Flir T1020 user manual — 32.2 Faulty contact in socket
Page 232 · click to enlarge
Page 232

Application examples 32

32.1 Moisture & water damage

32.1.1 General

It is often possible to detect moisture and water damage in a house by using an infrared camera. This is partly because the damaged area has a different heat conduction property and partly because it has a different thermal capacity to store heat than the surrounding material.

Many factors can come into play as to how moisture or water damage will appear in an in- frared image.

For example, heating and cooling of these parts takes place at different rates depending on the material and the time of day. For this reason, it is important that other methods are used as well to check for moisture or water damage.

32.1.2 Figure

The image below shows extensive water damage on an external wall where the water has penetrated the outer facing because of an incorrectly installed window ledge.

Flir T1020 — 32.1.2 Figure diagram (page 232)
Fig. 99 · 32.1.2 Figure

32.2 Faulty contact in socket

32.2.1 General

Depending on the type of connection a socket has, an improperly connected wire can re- sult in local temperature increase. This temperature increase is caused by the reduced contact area between the connection point of the incoming wire and the socket , and can result in an electrical fire.

A socket’s construction may differ dramatically from one manufacturer to another. For this reason, different faults in a socket can lead to the same typical appearance in an infrared image.

Local temperature increase can also result from improper contact between wire and sock- et, or from difference in load.

Page 233 of the Flir T1020 user manual — 32.3.2 Figure
Page 233 · click to enlarge
Page 233

Application examples 32

32.2.2 Figure

The image below shows a connection of a cable to a socket where improper contact in the connection has resulted in local temperature increase.

Flir T1020 — Application examples 32 diagram (page 233)
Fig. 100 · Application examples 32

32.3 Oxidized socket

32.3.1 General

Depending on the type of socket and the environment in which the socket is installed, ox- ides may occur on the socket's contact surfaces. These oxides can lead to locally in- creased resistance when the socket is loaded, which can be seen in an infrared image as local temperature increase.

A socket’s construction may differ dramatically from one manufacturer to another. For this reason, different faults in a socket can lead to the same typical appearance in an infrared image.

Local temperature increase can also result from improper contact between a wire and socket, or from difference in load.

32.3.2 Figure

The image below shows a series of fuses where one fuse has a raised temperature on the contact surfaces against the fuse holder. Because of the fuse holder’s blank metal, the temperature increase is not visible there, while it is visible on the fuse’s ceramic material.

Page 234 of the Flir T1020 user manual — 32.4.2 Figure
Page 234 · click to enlarge
Page 234

Application examples 32

Flir T1020 — Application examples 32 diagram (page 234)
Fig. 101 · Application examples 32

32.4 Insulation deficiencies

32.4.1 General

Insulation deficiencies may result from insulation losing volume over the course of time and thereby not entirely filling the cavity in a frame wall.

An infrared camera allows you to see these insulation deficiencies because they either have a different heat conduction property than sections with correctly installed insulation, and/or show the area where air is penetrating the frame of the building.

When you are inspecting a building, the temperature difference between the inside and outside should be at least 10°C (18°F). Studs, water pipes, concrete columns, and similar components may resemble an insulation deficiency in an infrared image. Minor differences may also occur naturally.

32.4.2 Figure

In the image below, insulation in the roof framing is lacking. Due to the absence of insula- tion, air has forced its way into the roof structure, which thus takes on a different character- istic appearance in the infrared image.

Page 235 of the Flir T1020 user manual — 32.5.2 Figure
Page 235 · click to enlarge
Page 235

Application examples 32

Flir T1020 — Application examples 32 diagram (page 235)
Fig. 102 · Application examples 32

32.5 Draft

32.5.1 General

Draft can be found under baseboards, around door and window casings, and above ceil- ing trim. This type of draft is often possible to see with an infrared camera, as a cooler air- stream cools down the surrounding surface.

When you are investigating draft in a house, there should be sub-atmospheric pressure in the house. Close all doors, windows, and ventilation ducts, and allow the kitchen fan to run for a while before you take the infrared images.

An infrared image of draft often shows a typical stream pattern. You can see this stream pattern clearly in the picture below.

Also keep in mind that drafts can be concealed by heat from floor heating circuits.

32.5.2 Figure

The image below shows a ceiling hatch where faulty installation has resulted in a strong draft.

Page 236 of the Flir T1020 user manual — Application examples 32
Page 236 · click to enlarge
Page 236

Application examples 32

Flir T1020 — Application examples 32 diagram (page 236)
Fig. 103 · Application examples 32
Page 237 of the Flir T1020 user manual — About FLIR Systems 33
Page 237 · click to enlarge
Page 237

About FLIR Systems 33

FLIR Systems was established in 1978 to pioneer the development of high-performance infrared imaging systems, and is the world leader in the design, manufacture, and market- ing of thermal imaging systems for a wide variety of commercial, industrial, and govern- ment applications. Today, FLIR Systems embraces five major companies with outstanding achievements in infrared technology since 1958—the Swedish AGEMA Infrared Systems (formerly AGA Infrared Systems), the three United States companies Indigo Systems, FSI, and Inframetrics, and the French company Cedip.

Since 2007, FLIR Systems has acquired several companies with world-leading expertise in sensor technologies:

  • Extech Instruments (2007)
  • Ifara Tecnologías (2008)
  • Salvador Imaging (2009)
  • OmniTech Partners (2009)
  • Directed Perception (2009)
  • Raymarine (2010)
  • ICx Technologies (2010)
  • TackTick Marine Digital Instruments (2011)
  • Aerius Photonics (2011)
  • Lorex Technology (2012)
  • Traficon (2012)
  • MARSS (2013)
  • DigitalOptics micro-optics business (2013)
  • DVTEL (2015)
Flir T1020 — About FLIR Systems 33 diagram (page 237)
Fig. 104 · About FLIR Systems 33

Figure 33.1 Patent documents from the early 1960s

FLIR Systems has three manufacturing plants in the United States (Portland, OR, Boston, MA, Santa Barbara, CA) and one in Sweden (Stockholm). Since 2007 there is also a man- ufacturing plant in Tallinn, Estonia. Direct sales offices in Belgium, Brazil, China, France, Germany, Great Britain, Hong Kong, Italy, Japan, Korea, Sweden, and the USA—together

Page 238 of the Flir T1020 user manual — 33.2 Sharing our knowledge
Page 238 · click to enlarge
Page 238

About FLIR Systems 33

with a worldwide network of agents and distributors—support our international customer base.

FLIR Systems is at the forefront of innovation in the infrared camera industry. We antici- pate market demand by constantly improving our existing cameras and developing new ones. The company has set milestones in product design and development such as the in- troduction of the first battery-operated portable camera for industrial inspections, and the first uncooled infrared camera, to mention just two innovations.

Flir T1020 — About FLIR Systems 33 diagram (page 238)
Fig. 105 · About FLIR Systems 33
Flir T1020 — About FLIR Systems 33 diagram (page 238)
Fig. 106 · About FLIR Systems 33

Figure 33.2 1969: Thermovision Model 661. The camera weighed approximately 25 kg (55 lb.), the oscilloscope 20 kg (44 lb.), and the tripod 15 kg (33 lb.). The operator also needed a 220 VAC gen- erator set, and a 10 L (2.6 US gallon) jar with liquid nitrogen. To the left of the oscilloscope the Polaroid attachment (6 kg/13 lb.) can be seen.

Figure 33.3 2015: FLIR One, an accessory to iPhone and Android mobile phones. Weight: 90 g (3.2 oz.).

FLIR Systems manufactures all vital mechanical and electronic components of the camera systems itself. From detector design and manufacturing, to lenses and system electronics, to final testing and calibration, all production steps are carried out and supervised by our own engineers. The in-depth expertise of these infrared specialists ensures the accuracy and reliability of all vital components that are assembled into your infrared camera.

33.1 More than just an infrared camera

At FLIR Systems we recognize that our job is to go beyond just producing the best infrared camera systems. We are committed to enabling all users of our infrared camera systems to work more productively by providing them with the most powerful camera–software combination. Especially tailored software for predictive maintenance, R & D, and process monitoring is developed in-house. Most software is available in a wide variety of languages.

We support all our infrared cameras with a wide variety of accessories to adapt your equip- ment to the most demanding infrared applications.

33.2 Sharing our knowledge

Although our cameras are designed to be very user-friendly, there is a lot more to thermog- raphy than just knowing how to handle a camera. Therefore, FLIR Systems has founded the Infrared Training Center (ITC), a separate business unit, that provides certified training courses. Attending one of the ITC courses will give you a truly hands-on learning experience.

Page 239 of the Flir T1020 user manual — 33.3 Supporting our customers
Page 239 · click to enlarge
Page 239

About FLIR Systems 33

The staff of the ITC are also there to provide you with any application support you may need in putting infrared theory into practice.

33.3 Supporting our customers

FLIR Systems operates a worldwide service network to keep your camera running at all times. If you discover a problem with your camera, local service centers have all the equip- ment and expertise to solve it within the shortest possible time. Therefore, there is no need to send your camera to the other side of the world or to talk to someone who does not speak your language.

Page 240 of the Flir T1020 user manual — Glossary 34
Page 240 · click to enlarge
Page 240

Glossary 34

The amount of radiation absorbed by an object relative to the re- ceived radiation. A number between 0 and 1.

atmosphere The gases between the object being measured and the camera, nor- mally air.

autoadjust A function making a camera perform an internal image correction.

autopalette The IR image is shown with an uneven spread of colors, displaying cold objects as well as hot ones at the same time.

blackbody Totally non-reflective object. All its radiation is due to its own temperature.

An IR radiating equipment with blackbody properties used to calibrate IR cameras.

A transmission value computed from the temperature, the relative hu- midity of air and the distance to the object.

cavity radiator A bottle shaped radiator with an absorbing inside, viewed through the bottleneck.

The temperature for which the color of a blackbody matches a specif- ic color.

conduction The process that makes heat diffuse into a material.

A function that adjusts the image. The function works all the time, continuously adjusting brightness and contrast according to the im- age content.

convection Convection is a heat transfer mode where a fluid is brought into mo- tion, either by gravity or another force, thereby transferring heat from one place to another.

dual isotherm An isotherm with two color bands, instead of one.

The amount of radiation coming from an object, compared to that of a blackbody. A number between 0 and 1.

emittance Amount of energy emitted from an object per unit of time and area (W/m2)

environment Objects and gases that emit radiation towards the object being measured.

A transmission value, supplied by a user, replacing a calculated one

external optics Extra lenses, filters, heat shields etc. that can be put between the camera and the object being measured.

filter A material transparent only to some of the infrared wavelengths.

FOV Field of view: The horizontal angle that can be viewed through an IR lens.

FPA Focal plane array: A type of IR detector.

graybody An object that emits a fixed fraction of the amount of energy of a blackbody for each wavelength.

Show 7 more labels / short text on this page
absorption (ab- sorption factor) · blackbody radiator · calculated at- mospheric transmission · color temperature · continuous adjust · emissivity (emissivity factor) · estimated at- mospheric transmission
Page 241 of the Flir T1020 user manual — Glossary 34
Page 241 · click to enlarge
Page 241

Glossary 34

IFOV Instantaneous field of view: A measure of the geometrical resolution of an IR camera.

image correc- tion (internal or external)

A way of compensating for sensitivity differences in various parts of live images and also of stabilizing the camera.

infrared Non-visible radiation, having a wavelength from about 2–13 μm.

isotherm A function highlighting those parts of an image that fall above, below or between one or more temperature intervals.

A bottle-shaped radiator with a uniform temperature viewed through the bottleneck.

Laser LocatIR An electrically powered light source on the camera that emits laser ra- diation in a thin, concentrated beam to point at certain parts of the ob- ject in front of the camera.

laser pointer An electrically powered light source on the camera that emits laser ra- diation in a thin, concentrated beam to point at certain parts of the ob- ject in front of the camera.

level The center value of the temperature scale, usually expressed as a signal value.

manual adjust A way to adjust the image by manually changing certain parameters.

NETD Noise equivalent temperature difference. A measure of the image noise level of an IR camera.

noise Undesired small disturbance in the infrared image

A set of values describing the circumstances under which the meas- urement of an object was made, and the object itself (such as emis- sivity, reflected apparent temperature, distance etc.)

object signal A non-calibrated value related to the amount of radiation received by the camera from the object.

palette The set of colors used to display an IR image.

pixel Stands for picture element. One single spot in an image.

radiance Amount of energy emitted from an object per unit of time, area and angle (W/m2/sr)

radiant power Amount of energy emitted from an object per unit of time (W)

radiation The process by which electromagnetic energy, is emitted by an object or a gas.

radiator A piece of IR radiating equipment.

range The current overall temperature measurement limitation of an IR cam- era. Cameras can have several ranges. Expressed as two blackbody temperatures that limit the current calibration.

A temperature which the ordinary measured values can be compared with.

reflection The amount of radiation reflected by an object relative to the received radiation. A number between 0 and 1.

Show 4 more labels / short text on this page
IR infrared · isothermal cavity · object parameters · reference temperature
Page 242 of the Flir T1020 user manual — Glossary 34
Page 242 · click to enlarge
Page 242

Glossary 34

Relative humidity represents the ratio between the current water va- pour mass in the air and the maximum it may contain in saturation conditions.

The areas that contain temperatures outside the present level/span settings are colored with the saturation colors. The saturation colors contain an ‘overflow’ color and an ‘underflow’ color. There is also a third red saturation color that marks everything saturated by the de- tector indicating that the range should probably be changed.

span The interval of the temperature scale, usually expressed as a signal value.

Amount of energy emitted from an object per unit of time, area and wavelength (W/m2/μm)

temperature difference, or difference of temperature.

A value which is the result of a subtraction between two temperature values.

The current overall temperature measurement limitation of an IR cam- era. Cameras can have several ranges. Expressed as two blackbody temperatures that limit the current calibration.

The way in which an IR image currently is displayed. Expressed as two temperature values limiting the colors.

transmission (or transmit- tance) factor

Gases and materials can be more or less transparent. Transmission is the amount of IR radiation passing through them. A number be- tween 0 and 1.

An isotherm showing a linear spread of colors, instead of covering the highlighted parts of the image.

visual Refers to the video mode of a IR camera, as opposed to the normal, thermographic mode. When a camera is in video mode it captures or- dinary video images, while thermographic images are captured when the camera is in IR mode.

Show 7 more labels / short text on this page
relative humidity · saturation color · spectral (radi- ant) emittance · temperature range · temperature scale · thermogram infrared image · transparent isotherm
Page 243 of the Flir T1020 user manual — 35.2.1 Finding the emissivity of a sample
Page 243 · click to enlarge
Page 243

Thermographic measurement techniques 35

35.1 Introduction

An infrared camera measures and images the emitted infrared radiation from an object. The fact that radiation is a function of object surface temperature makes it possible for the camera to calculate and display this temperature.

However, the radiation measured by the camera does not only depend on the temperature of the object but is also a function of the emissivity. Radiation also originates from the sur- roundings and is reflected in the object. The radiation from the object and the reflected ra- diation will also be influenced by the absorption of the atmosphere.

To measure temperature accurately, it is therefore necessary to compensate for the effects of a number of different radiation sources. This is done on-line automatically by the cam- era. The following object parameters must, however, be supplied for the camera:

  • The emissivity of the object
  • The reflected apparent temperature
  • The distance between the object and the camera
  • The relative humidity
  • Temperature of the atmosphere

35.2 Emissivity

The most important object parameter to set correctly is the emissivity which, in short, is a measure of how much radiation is emitted from the object, compared to that from a perfect blackbody of the same temperature.

Normally, object materials and surface treatments exhibit emissivity ranging from approxi- mately 0.1 to 0.95. A highly polished (mirror) surface falls below 0.1, while an oxidized or painted surface has a higher emissivity. Oil-based paint, regardless of color in the visible spectrum, has an emissivity over 0.9 in the infrared. Human skin exhibits an emissivity 0.97 to 0.98.

Non-oxidized metals represent an extreme case of perfect opacity and high reflexivity, which does not vary greatly with wavelength. Consequently, the emissivity of metals is low – only increasing with temperature. For non-metals, emissivity tends to be high, and de- creases with temperature.

35.2.1 Finding the emissivity of a sample

35.2.1.1 Step 1Determining reflected apparent temperature

Use one of the following two methods to determine reflected apparent temperature:

Page 244 of the Flir T1020 user manual — Thermographic measurement techniques 35
Page 244 · click to enlarge
Page 244

Thermographic measurement techniques 35

35.2.1.1.1 Method 1Direct method

Follow this procedure:

1. Look for possible reflection sources, considering that the incident angle = reflection angle (a = b).
Flir T1020 — Thermographic measurement techniques 35 diagram (page 244)
Fig. 107 · Thermographic measurement techniques 35

Figure 35.1 1 = Reflection source

2. If the reflection source is a spot source, modify the source by obstructing it using a piece if cardboard.
Flir T1020 — Thermographic measurement techniques 35 diagram (page 244)
Fig. 108 · Thermographic measurement techniques 35

Figure 35.2 1 = Reflection source

Page 245 of the Flir T1020 user manual — Thermographic measurement techniques 35
Page 245 · click to enlarge
Page 245

Thermographic measurement techniques 35

3. Measure the radiation intensity (= apparent temperature) from the reflecting source using the following settings:
  • Emissivity: 1.0
  • D obj : 0

You can measure the radiation intensity using one of the following two methods:

Flir T1020 — Thermographic measurement techniques 35 diagram (page 245)
Fig. 109 · Thermographic measurement techniques 35
Flir T1020 — Thermographic measurement techniques 35 diagram (page 245)
Fig. 110 · Thermographic measurement techniques 35

Figure 35.3 1 = Reflection source

Figure 35.4 1 = Reflection source

Using a thermocouple to measure reflected apparent temperature is not recommended for two important reasons:

  • A thermocouple does not measure radiation intensity
  • A thermocouple requires a very good thermal contact to the surface, usually by gluing and covering the sensor by a thermal isolator.
35.2.1.1.2 Method 2Reflector method

Follow this procedure:

1. Crumble up a large piece of aluminum foil. 2. Uncrumble the aluminum foil and attach it to a piece of cardboard of the same size. 3. Put the piece of cardboard in front of the object you want to measure. Make sure that the side with aluminum foil points to the camera. 4. Set the emissivity to 1.0.
Page 246 of the Flir T1020 user manual — Note
Page 246 · click to enlarge
Page 246

Thermographic measurement techniques 35

5. Measure the apparent temperature of the aluminum foil and write it down.
Flir T1020 — Thermographic measurement techniques 35 diagram (page 246)
Fig. 111 · Thermographic measurement techniques 35

Figure 35.5 Measuring the apparent temperature of the aluminum foil.

35.2.1.2 Step 2Determining the emissivity

Follow this procedure:

1. Select a place to put the sample. 2. Determine and set reflected apparent temperature according to the previous procedure. 3. Put a piece of electrical tape with known high emissivity on the sample. 4. Heat the sample at least 20 K above room temperature. Heating must be reasonably even. 5. Focus and auto-adjust the camera, and freeze the image. 6. Adjust Level and Span for best image brightness and contrast. 7. Set emissivity to that of the tape (usually 0.97). 8. Measure the temperature of the tape using one of the following measurement functions:

  • Isotherm (helps you to determine both the temperature and how evenly you have heated the sample)
  • Spot (simpler)
  • Box Avg (good for surfaces with varying emissivity).
9. Write down the temperature. 10. Move your measurement function to the sample surface. 11. Change the emissivity setting until you read the same temperature as your previous measurement. 12. Write down the emissivity.

Note

  • Avoid forced convection
  • Look for a thermally stable surrounding that will not generate spot reflections
  • Use high quality tape that you know is not transparent, and has a high emissivity you are certain of
  • This method assumes that the temperature of your tape and the sample surface are the same. If they are not, your emissivity measurement will be wrong.
Page 247 of the Flir T1020 user manual — 35.6 Other parameters
Page 247 · click to enlarge
Page 247

Thermographic measurement techniques 35

35.3 Reflected apparent temperature

This parameter is used to compensate for the radiation reflected in the object. If the emis- sivity is low and the object temperature relatively far from that of the reflected it will be im- portant to set and compensate for the reflected apparent temperature correctly.

35.4 Distance

The distance is the distance between the object and the front lens of the camera. This pa- rameter is used to compensate for the following two facts:

  • That radiation from the target is absorbed by the atmosphere between the object and the camera.
  • That radiation from the atmosphere itself is detected by the camera.

35.5 Relative humidity

The camera can also compensate for the fact that the transmittance is also dependent on the relative humidity of the atmosphere. To do this set the relative humidity to the correct value. For short distances and normal humidity the relative humidity can normally be left at a default value of 50%.

35.6 Other parameters

In addition, some cameras and analysis programs from FLIR Systems allow you to com- pensate for the following parameters:

  • Atmospheric temperature – i.e. the temperature of the atmosphere between the camera and the target
  • External optics temperature – i.e. the temperature of any external lenses or windows used in front of the camera
  • External optics transmittance – i.e. the transmission of any external lenses or windows used in front of the camera
Page 248 of the Flir T1020 user manual — History of infrared technology 36
Page 248 · click to enlarge
Page 248

History of infrared technology 36

Before the year 1800, the existence of the infrared portion of the electromagnetic spectrum wasn't even suspected. The original significance of the infrared spectrum, or simply ‘the in- frared’ as it is often called, as a form of heat radiation is perhaps less obvious today than it was at the time of its discovery by Herschel in 1800.

Flir T1020 — History of infrared technology 36 diagram (page 248)
Fig. 112 · History of infrared technology 36

Figure 36.1 Sir William Herschel (1738–1822)

The discovery was made accidentally during the search for a new optical material. Sir Wil- liam Herschel – Royal Astronomer to King George III of England, and already famous for his discovery of the planet Uranus – was searching for an optical filter material to reduce the brightness of the sun’s image in telescopes during solar observations. While testing different samples of colored glass which gave similar reductions in brightness he was in- trigued to find that some of the samples passed very little of the sun’s heat, while others passed so much heat that he risked eye damage after only a few seconds’ observation.

Herschel was soon convinced of the necessity of setting up a systematic experiment, with the objective of finding a single material that would give the desired reduction in brightness as well as the maximum reduction in heat. He began the experiment by actually repeating Newton’s prism experiment, but looking for the heating effect rather than the visual distri- bution of intensity in the spectrum. He first blackened the bulb of a sensitive mercury-in- glass thermometer with ink, and with this as his radiation detector he proceeded to test the heating effect of the various colors of the spectrum formed on the top of a table by passing sunlight through a glass prism. Other thermometers, placed outside the sun’s rays, served as controls.

As the blackened thermometer was moved slowly along the colors of the spectrum, the temperature readings showed a steady increase from the violet end to the red end. This was not entirely unexpected, since the Italian researcher, Landriani, in a similar experiment in 1777 had observed much the same effect. It was Herschel, however, who was the first to recognize that there must be a point where the heating effect reaches a maximum, and that measurements confined to the visible portion of the spectrum failed to locate this point.

Flir T1020 — History of infrared technology 36 diagram (page 248)
Fig. 113 · History of infrared technology 36

Figure 36.2 Marsilio Landriani (1746–1815)

Page 249 of the Flir T1020 user manual — History of infrared technology 36
Page 249 · click to enlarge
Page 249

History of infrared technology 36

Moving the thermometer into the dark region beyond the red end of the spectrum, Her- schel confirmed that the heating continued to increase. The maximum point, when he found it, lay well beyond the red end – in what is known today as the ‘infrared wavelengths’.

When Herschel revealed his discovery, he referred to this new portion of the electromag- netic spectrum as the ‘thermometrical spectrum’. The radiation itself he sometimes re- ferred to as ‘dark heat’, or simply ‘the invisible rays’. Ironically, and contrary to popular opinion, it wasn't Herschel who originated the term ‘infrared’. The word only began to ap- pear in print around 75 years later, and it is still unclear who should receive credit as the originator.

Herschel’s use of glass in the prism of his original experiment led to some early controver- sies with his contemporaries about the actual existence of the infrared wavelengths. Differ- ent investigators, in attempting to confirm his work, used various types of glass indiscriminately, having different transparencies in the infrared. Through his later experi- ments, Herschel was aware of the limited transparency of glass to the newly-discovered thermal radiation, and he was forced to conclude that optics for the infrared would prob- ably be doomed to the use of reflective elements exclusively (i.e. plane and curved mir- rors). Fortunately, this proved to be true only until 1830, when the Italian investigator, Melloni, made his great discovery that naturally occurring rock salt (NaCl) – which was available in large enough natural crystals to be made into lenses and prisms – is remark- ably transparent to the infrared. The result was that rock salt became the principal infrared optical material, and remained so for the next hundred years, until the art of synthetic crys- tal growing was mastered in the 1930’s.

Flir T1020 — History of infrared technology 36 diagram (page 249)
Fig. 114 · History of infrared technology 36

Figure 36.3 Macedonio Melloni (1798–1854)

Thermometers, as radiation detectors, remained unchallenged until 1829, the year Nobili invented the thermocouple. (Herschel’s own thermometer could be read to 0.2 °C (0.036 ° F), and later models were able to be read to 0.05 °C (0.09 °F)). Then a breakthrough oc- curred; Melloni connected a number of thermocouples in series to form the first thermopile. The new device was at least 40 times as sensitive as the best thermometer of the day for detecting heat radiation – capable of detecting the heat from a person standing three me- ters away.

The first so-called ‘heat-picture’ became possible in 1840, the result of work by Sir John Herschel, son of the discoverer of the infrared and a famous astronomer in his own right. Based upon the differential evaporation of a thin film of oil when exposed to a heat pattern focused upon it, the thermal image could be seen by reflected light where the interference effects of the oil film made the image visible to the eye. Sir John also managed to obtain a primitive record of the thermal image on paper, which he called a ‘thermograph’.

Page 250 of the Flir T1020 user manual — History of infrared technology 36
Page 250 · click to enlarge
Page 250

History of infrared technology 36

Flir T1020 — History of infrared technology 36 diagram (page 250)
Fig. 115 · History of infrared technology 36

Figure 36.4 Samuel P. Langley (1834–1906)

The improvement of infrared-detector sensitivity progressed slowly. Another major break- through, made by Langley in 1880, was the invention of the bolometer. This consisted of a thin blackened strip of platinum connected in one arm of a Wheatstone bridge circuit upon which the infrared radiation was focused and to which a sensitive galvanometer re- sponded. This instrument is said to have been able to detect the heat from a cow at a dis- tance of 400 meters.

An English scientist, Sir James Dewar, first introduced the use of liquefied gases as cool- ing agents (such as liquid nitrogen with a temperature of -196 °C (-320.8 °F)) in low tem- perature research. In 1892 he invented a unique vacuum insulating container in which it is possible to store liquefied gases for entire days. The common ‘thermos bottle’, used for storing hot and cold drinks, is based upon his invention.

Between the years 1900 and 1920, the inventors of the world ‘discovered’ the infrared. Many patents were issued for devices to detect personnel, artillery, aircraft, ships – and even icebergs. The first operating systems, in the modern sense, began to be developed during the 1914–18 war, when both sides had research programs devoted to the military exploitation of the infrared. These programs included experimental systems for enemy in- trusion/detection, remote temperature sensing, secure communications, and ‘flying torpe- do’ guidance. An infrared search system tested during this period was able to detect an approaching airplane at a distance of 1.5 km (0.94 miles), or a person more than 300 me- ters (984 ft.) away.

The most sensitive systems up to this time were all based upon variations of the bolometer idea, but the period between the two wars saw the development of two revolutionary new infrared detectors: the image converter and the photon detector. At first, the image con- verter received the greatest attention by the military, because it enabled an observer for the first time in history to literally ‘see in the dark’. However, the sensitivity of the image converter was limited to the near infrared wavelengths, and the most interesting military targets (i.e. enemy soldiers) had to be illuminated by infrared search beams. Since this in- volved the risk of giving away the observer’s position to a similarly-equipped enemy ob- server, it is understandable that military interest in the image converter eventually faded.

The tactical military disadvantages of so-called 'active’ (i.e. search beam-equipped) ther- mal imaging systems provided impetus following the 1939–45 war for extensive secret military infrared-research programs into the possibilities of developing ‘passive’ (no search beam) systems around the extremely sensitive photon detector. During this period, military secrecy regulations completely prevented disclosure of the status of infrared-imaging technology. This secrecy only began to be lifted in the middle of the 1950’s, and from that time adequate thermal-imaging devices finally began to be available to civilian science and industry.

Page 251 of the Flir T1020 user manual — 37.3 Blackbody radiation
Page 251 · click to enlarge
Page 251

Theory of thermography 37

37.1 Introduction

The subjects of infrared radiation and the related technique of thermography are still new to many who will use an infrared camera. In this section the theory behind thermography will be given.

37.2 The electromagnetic spectrum

The electromagnetic spectrum is divided arbitrarily into a number of wavelength regions, called bands, distinguished by the methods used to produce and detect the radiation. There is no fundamental difference between radiation in the different bands of the electro- magnetic spectrum. They are all governed by the same laws and the only differences are those due to differences in wavelength.

Flir T1020 — 37.2 The electromagnetic spectrum diagram (page 251)
Fig. 116 · 37.2 The electromagnetic spectrum

Figure 37.1 The electromagnetic spectrum. 1: X-ray; 2: UV; 3: Visible; 4: IR; 5: Microwaves; 6: Radiowaves.

Thermography makes use of the infrared spectral band. At the short-wavelength end the boundary lies at the limit of visual perception, in the deep red. At the long-wavelength end it merges with the microwave radio wavelengths, in the millimeter range.

The infrared band is often further subdivided into four smaller bands, the boundaries of which are also arbitrarily chosen. They include: the near infrared (0.75–3 μm), the middle infrared (3–6 μm), the far infrared (6–15 μm) and the extreme infrared (15–100 μm). Although the wavelengths are given in μm (micrometers), other units are often still used to measure wavelength in this spectral region, e.g. nanometer (nm) and Ångström (Å).

The relationships between the different wavelength measurements is:

37.3 Blackbody radiation

A blackbody is defined as an object which absorbs all radiation that impinges on it at any wavelength. The apparent misnomer black relating to an object emitting radiation is ex- plained by Kirchhoff’s Law (after Gustav Robert Kirchhoff, 1824–1887), which states that a body capable of absorbing all radiation at any wavelength is equally capable in the emis- sion of radiation.

Page 252 of the Flir T1020 user manual — 37.3.1 Planck’s law
Page 252 · click to enlarge
Page 252

Theory of thermography 37

Flir T1020 — Theory of thermography 37 diagram (page 252)
Fig. 117 · Theory of thermography 37

Figure 37.2 Gustav Robert Kirchhoff (1824–1887)

The construction of a blackbody source is, in principle, very simple. The radiation charac- teristics of an aperture in an isotherm cavity made of an opaque absorbing material repre- sents almost exactly the properties of a blackbody. A practical application of the principle to the construction of a perfect absorber of radiation consists of a box that is light tight ex- cept for an aperture in one of the sides. Any radiation which then enters the hole is scat- tered and absorbed by repeated reflections so only an infinitesimal fraction can possibly escape. The blackness which is obtained at the aperture is nearly equal to a blackbody and almost perfect for all wavelengths.

By providing such an isothermal cavity with a suitable heater it becomes what is termed a cavity radiator. An isothermal cavity heated to a uniform temperature generates blackbody radiation, the characteristics of which are determined solely by the temperature of the cav- ity. Such cavity radiators are commonly used as sources of radiation in temperature refer- ence standards in the laboratory for calibrating thermographic instruments, such as a FLIR Systems camera for example.

If the temperature of blackbody radiation increases to more than 525°C (977°F), the source begins to be visible so that it appears to the eye no longer black. This is the incipi- ent red heat temperature of the radiator, which then becomes orange or yellow as the tem- perature increases further. In fact, the definition of the so-called color temperature of an object is the temperature to which a blackbody would have to be heated to have the same appearance.

Now consider three expressions that describe the radiation emitted from a blackbody.

37.3.1 Planck’s law

Flir T1020 — 37.3.1 Planck’s law diagram (page 252)
Fig. 118 · 37.3.1 Planck’s law

Figure 37.3 Max Planck (1858–1947)

Max Planck (1858–1947) was able to describe the spectral distribution of the radiation from a blackbody by means of the following formula:

Page 253 of the Flir T1020 user manual — 37.3.2 Wien’s displacement law
Page 253 · click to enlarge
Page 253

Theory of thermography 37

where:

Wλb Blackbody spectral radiant emittance at wavelength λ.

c Velocity of light = 3 × 108 m/s

h Planck’s constant = 6.6 × 10-34 Joule sec.

k Boltzmann’s constant = 1.4 × 10-23 Joule/K.

T Absolute temperature (K) of a blackbody.

λ Wavelength (μm).

Planck’s formula, when plotted graphically for various temperatures, produces a family of curves. Following any particular Planck curve, the spectral emittance is zero at λ = 0, then increases rapidly to a maximum at a wavelength λmax and after passing it approaches zero again at very long wavelengths. The higher the temperature, the shorter the wavelength at which maximum occurs.

Flir T1020 — Theory of thermography 37 diagram (page 253)
Fig. 119 · Theory of thermography 37

Figure 37.4 Blackbody spectral radiant emittance according to Planck’s law, plotted for various absolute temperatures. 1: Spectral radiant emittance (W/cm2 × 103(μm)); 2: Wavelength (μm)

37.3.2 Wien’s displacement law

By differentiating Planck’s formula with respect to λ, and finding the maximum, we have:

This is Wien’s formula (after Wilhelm Wien, 1864–1928), which expresses mathematically the common observation that colors vary from red to orange or yellow as the temperature of a thermal radiator increases. The wavelength of the color is the same as the wavelength calculated for λmax. A good approximation of the value of λmax for a given blackbody

Page 254 of the Flir T1020 user manual — 37.3.3 Stefan-Boltzmann's law
Page 254 · click to enlarge
Page 254

Theory of thermography 37

temperature is obtained by applying the rule-of-thumb 3 000/T μm. Thus, a very hot star such as Sirius (11 000 K), emitting bluish-white light, radiates with the peak of spectral ra- diant emittance occurring within the invisible ultraviolet spectrum, at wavelength 0.27 μm.

Flir T1020 — Theory of thermography 37 diagram (page 254)
Fig. 120 · Theory of thermography 37

Figure 37.5 Wilhelm Wien (1864–1928)

The sun (approx. 6 000 K) emits yellow light, peaking at about 0.5 μm in the middle of the visible light spectrum.

At room temperature (300 K) the peak of radiant emittance lies at 9.7 μm, in the far infra- red, while at the temperature of liquid nitrogen (77 K) the maximum of the almost insignifi- cant amount of radiant emittance occurs at 38 μm, in the extreme infrared wavelengths.

Flir T1020 — Theory of thermography 37 diagram (page 254)
Fig. 121 · Theory of thermography 37

Figure 37.6 Planckian curves plotted on semi-log scales from 100 K to 1000 K. The dotted line represents the locus of maximum radiant emittance at each temperature as described by Wien's displacement law. 1: Spectral radiant emittance (W/cm2 (μm)); 2: Wavelength (μm).

37.3.3 Stefan-Boltzmann's law

By integrating Planck’s formula from λ = 0 to λ = ∞, we obtain the total radiant emittance (Wb) of a blackbody:

Page 255 of the Flir T1020 user manual — 37.3.4 Non-blackbody emitters
Page 255 · click to enlarge
Page 255

Theory of thermography 37

This is the Stefan-Boltzmann formula (after Josef Stefan, 1835–1893, and Ludwig Boltz- mann, 1844–1906), which states that the total emissive power of a blackbody is propor- tional to the fourth power of its absolute temperature. Graphically, Wb represents the area below the Planck curve for a particular temperature. It can be shown that the radiant emit- tance in the interval λ = 0 to λmax is only 25% of the total, which represents about the amount of the sun’s radiation which lies inside the visible light spectrum.

Flir T1020 — Theory of thermography 37 diagram (page 255)
Fig. 122 · Theory of thermography 37

Figure 37.7 Josef Stefan (1835–1893), and Ludwig Boltzmann (1844–1906)

Using the Stefan-Boltzmann formula to calculate the power radiated by the human body, at a temperature of 300 K and an external surface area of approx. 2 m2, we obtain 1 kW. This power loss could not be sustained if it were not for the compensating absorption of ra- diation from surrounding surfaces, at room temperatures which do not vary too drastically from the temperature of the body – or, of course, the addition of clothing.

37.3.4 Non-blackbody emitters

So far, only blackbody radiators and blackbody radiation have been discussed. However, real objects almost never comply with these laws over an extended wavelength region – although they may approach the blackbody behavior in certain spectral intervals. For ex- ample, a certain type of white paint may appear perfectly white in the visible light spec- trum, but becomes distinctly gray at about 2 μm, and beyond 3 μm it is almost black.

There are three processes which can occur that prevent a real object from acting like a blackbody: a fraction of the incident radiation α may be absorbed, a fraction ρ may be re- flected, and a fraction τ may be transmitted. Since all of these factors are more or less wavelength dependent, the subscript λ is used to imply the spectral dependence of their definitions. Thus:

  • The spectral absorptance α λ = the ratio of the spectral radiant power absorbed by an object to that incident upon it.
  • The spectral reflectance ρ λ = the ratio of the spectral radiant power reflected by an object to that incident upon it.
  • The spectral transmittance τ λ = the ratio of the spectral radiant power transmitted through an object to that incident upon it.

The sum of these three factors must always add up to the whole at any wavelength, so we have the relation:

For opaque materials τλ = 0 and the relation simplifies to:

Another factor, called the emissivity, is required to describe the fraction ε of the radiant emittance of a blackbody produced by an object at a specific temperature. Thus, we have the definition:

Page 256 of the Flir T1020 user manual — Theory of thermography 37
Page 256 · click to enlarge
Page 256

Theory of thermography 37

The spectral emissivity ελ= the ratio of the spectral radiant power from an object to that from a blackbody at the same temperature and wavelength.

Expressed mathematically, this can be written as the ratio of the spectral emittance of the object to that of a blackbody as follows:

Generally speaking, there are three types of radiation source, distinguished by the ways in which the spectral emittance of each varies with wavelength.

  • A blackbody, for which ε λ = ε = 1
  • A graybody, for which ε λ = ε = constant less than 1
  • A selective radiator, for which ε varies with wavelength

According to Kirchhoff’s law, for any material the spectral emissivity and spectral absorp- tance of a body are equal at any specified temperature and wavelength. That is:

From this we obtain, for an opaque material (since αλ + ρλ = 1):

For highly polished materials ελ approaches zero, so that for a perfectly reflecting material (i.e. a perfect mirror) we have:

For a graybody radiator, the Stefan-Boltzmann formula becomes:

This states that the total emissive power of a graybody is the same as a blackbody at the same temperature reduced in proportion to the value of ε from the graybody.

Flir T1020 — Theory of thermography 37 diagram (page 256)
Fig. 123 · Theory of thermography 37

Figure 37.8 Spectral radiant emittance of three types of radiators. 1: Spectral radiant emittance; 2: Wave- length; 3: Blackbody; 4: Selective radiator; 5: Graybody.

Page 257 of the Flir T1020 user manual — 37.4 Infrared semi-transparent materials
Page 257 · click to enlarge
Page 257

Theory of thermography 37

Flir T1020 — Theory of thermography 37 diagram (page 257)
Fig. 124 · Theory of thermography 37

Figure 37.9 Spectral emissivity of three types of radiators. 1: Spectral emissivity; 2: Wavelength; 3: Black- body; 4: Graybody; 5: Selective radiator.

37.4 Infrared semi-transparent materials

Consider now a non-metallic, semi-transparent body – let us say, in the form of a thick flat plate of plastic material. When the plate is heated, radiation generated within its volume must work its way toward the surfaces through the material in which it is partially absorbed. Moreover, when it arrives at the surface, some of it is reflected back into the interior. The back-reflected radiation is again partially absorbed, but some of it arrives at the other sur- face, through which most of it escapes; part of it is reflected back again. Although the pro- gressive reflections become weaker and weaker they must all be added up when the total emittance of the plate is sought. When the resulting geometrical series is summed, the ef- fective emissivity of a semi-transparent plate is obtained as:

When the plate becomes opaque this formula is reduced to the single formula:

This last relation is a particularly convenient one, because it is often easier to measure re- flectance than to measure emissivity directly.

Page 258 of the Flir T1020 user manual — The measurement formula 38
Page 258 · click to enlarge
Page 258

The measurement formula 38

As already mentioned, when viewing an object, the camera receives radiation not only from the object itself. It also collects radiation from the surroundings reflected via the ob- ject surface. Both these radiation contributions become attenuated to some extent by the atmosphere in the measurement path. To this comes a third radiation contribution from the atmosphere itself.

This description of the measurement situation, as illustrated in the figure below, is so far a fairly true description of the real conditions. What has been neglected could for instance be sun light scattering in the atmosphere or stray radiation from intense radiation sources outside the field of view. Such disturbances are difficult to quantify, however, in most cases they are fortunately small enough to be neglected. In case they are not negligible, the measurement configuration is likely to be such that the risk for disturbance is obvious, at least to a trained operator. It is then his responsibility to modify the measurement situation to avoid the disturbance e.g. by changing the viewing direction, shielding off intense radia- tion sources etc.

Accepting the description above, we can use the figure below to derive a formula for the calculation of the object temperature from the calibrated camera output.

Flir T1020 — The measurement formula 38 diagram (page 258)
Fig. 125 · The measurement formula 38

Figure 38.1 A schematic representation of the general thermographic measurement situation.1: Surround- ings; 2: Object; 3: Atmosphere; 4: Camera

Assume that the received radiation power W from a blackbody source of temperature Tsource on short distance generates a camera output signal Usource that is proportional to the power input (power linear camera). We can then write (Equation 1):

or, with simplified notation:

where C is a constant.

Should the source be a graybody with emittance ε, the received radiation would conse- quently be εWsource.

We are now ready to write the three collected radiation power terms:

1. Emission from the object = ετW obj , where ε is the emittance of the object and τ is the transmittance of the atmosphere. The object temperature is T obj .
Page 259 of the Flir T1020 user manual — The measurement formula 38
Page 259 · click to enlarge
Page 259

The measurement formula 38

2. Reflected emission from ambient sources = (1 – ε)τWrefl, where (1 – ε) is the reflec- tance of the object. The ambient sources have the temperature Trefl. It has here been assumed that the temperature Trefl is the same for all emitting surfaces within the halfsphere seen from a point on the object surface. This is of course some- times a simplification of the true situation. It is, however, a necessary simplification in order to derive a workable formula, and Trefl can – at least theoretically – be given a val- ue that represents an efficient temperature of a complex surrounding.

3. Emission from the atmosphere = (1 – τ)τW atm , where (1 – τ) is the emittance of the atmosphere. The temperature of the atmosphere is T atm .

The total received radiation power can now be written (Equation 2):

We multiply each term by the constant C of Equation 1 and replace the CW products by the corresponding U according to the same equation, and get (Equation 3):

Solve Equation 3 for Uobj (Equation 4):

This is the general measurement formula used in all the FLIR Systems thermographic equipment. The voltages of the formula are:

Table 38.1 Voltages

Uobj Calculated camera output voltage for a blackbody of temperature Tobj i.e. a voltage that can be directly converted into true requested object temperature.

Utot Measured camera output voltage for the actual case.

Urefl Theoretical camera output voltage for a blackbody of temperature Trefl according to the calibration.

Uatm Theoretical camera output voltage for a blackbody of temperature Tatm according to the calibration.

The operator has to supply a number of parameter values for the calculation:

  • the object emittance ε,
  • the relative humidity,
  • T atm
  • object distance (D obj )
  • the (effective) temperature of the object surroundings, or the reflected ambient temperature T refl , and
  • the temperature of the atmosphere T atm

This task could sometimes be a heavy burden for the operator since there are normally no easy ways to find accurate values of emittance and atmospheric transmittance for the

Page 260 of the Flir T1020 user manual — The measurement formula 38
Page 260 · click to enlarge
Page 260

The measurement formula 38

actual case. The two temperatures are normally less of a problem provided the surround- ings do not contain large and intense radiation sources.

A natural question in this connection is: How important is it to know the right values of these parameters? It could though be of interest to get a feeling for this problem already here by looking into some different measurement cases and compare the relative magni- tudes of the three radiation terms. This will give indications about when it is important to use correct values of which parameters.

The figures below illustrates the relative magnitudes of the three radiation contributions for three different object temperatures, two emittances, and two spectral ranges: SW and LW. Remaining parameters have the following fixed values:

  • τ = 0.88
  • T refl = +20°C (+68°F)
  • T atm = +20°C (+68°F)

It is obvious that measurement of low object temperatures are more critical than measur- ing high temperatures since the ‘disturbing’ radiation sources are relatively much stronger in the first case. Should also the object emittance be low, the situation would be still more difficult.

We have finally to answer a question about the importance of being allowed to use the cal- ibration curve above the highest calibration point, what we call extrapolation. Imagine that we in a certain case measure Utot = 4.5 volts. The highest calibration point for the camera was in the order of 4.1 volts, a value unknown to the operator. Thus, even if the object hap- pened to be a blackbody, i.e. Uobj = Utot, we are actually performing extrapolation of the calibration curve when converting 4.5 volts into temperature.

Let us now assume that the object is not black, it has an emittance of 0.75, and the trans- mittance is 0.92. We also assume that the two second terms of Equation 4 amount to 0.5 volts together. Computation of Uobj by means of Equation 4 then results in Uobj = 4.5 / 0.75 / 0.92 – 0.5 = 6.0. This is a rather extreme extrapolation, particularly when considering that the video amplifier might limit the output to 5 volts! Note, though, that the application of the calibration curve is a theoretical procedure where no electronic or other limitations exist. We trust that if there had been no signal limitations in the camera, and if it had been cali- brated far beyond 5 volts, the resulting curve would have been very much the same as our real curve extrapolated beyond 4.1 volts, provided the calibration algorithm is based on ra- diation physics, like the FLIR Systems algorithm. Of course there must be a limit to such extrapolations.

Page 261 of the Flir T1020 user manual — The measurement formula 38
Page 261 · click to enlarge
Page 261

The measurement formula 38

Flir T1020 — The measurement formula 38 diagram (page 261)
Fig. 126 · The measurement formula 38

Figure 38.2 Relative magnitudes of radiation sources under varying measurement conditions (SW camera). 1: Object temperature; 2: Emittance; Obj: Object radiation; Refl: Reflected radiation; Atm: atmosphere radia- tion. Fixed parameters: τ = 0.88; Trefl = 20°C (+68°F); Tatm = 20°C (+68°F).

Flir T1020 — The measurement formula 38 diagram (page 261)
Fig. 127 · The measurement formula 38

Figure 38.3 Relative magnitudes of radiation sources under varying measurement conditions (LW camera). 1: Object temperature; 2: Emittance; Obj: Object radiation; Refl: Reflected radiation; Atm: atmosphere radia- tion. Fixed parameters: τ = 0.88; Trefl = 20°C (+68°F); Tatm = 20°C (+68°F).

Page 262 of the Flir T1020 user manual — 70 SW 0.67 9
Page 262 · click to enlarge
Page 262

Emissivity tables 39

This section presents a compilation of emissivity data from the infrared literature and measurements made by FLIR Systems.

39.1 References

1. Mikaél A. Bramson: Infrared Radiation, A Handbook for Applications, Plenum press, N. Y. 2. William L. Wolfe, George J. Zissis: The Infrared Handbook, Office of Naval Research, Department of Navy, Washington, D.C. 3. Madding, R. P.: Thermographic Instruments and systems. Madison, Wisconsin: Univer- sity of Wisconsin – Extension, Department of Engineering and Applied Science. 4. William L. Wolfe: Handbook of Military Infrared Technology, Office of Naval Research, Department of Navy, Washington, D.C. 5. Jones, Smith, Probert: External thermography of buildings..., Proc. of the Society of Photo-Optical Instrumentation Engineers, vol.110, Industrial and Civil Applications of Infrared Technology, June 1977 London. 6. Paljak, Pettersson: Thermography of Buildings, Swedish Building Research Institute, Stockholm 1972. 7. Vlcek, J: Determination of emissivity with imaging radiometers and some emissivities at λ = 5 µm. Photogrammetric Engineering and Remote Sensing. 8. Kern: Evaluation of infrared emission of clouds and ground as measured by weather satellites, Defence Documentation Center, AD 617 417. 9. Öhman, Claes: Emittansmätningar med AGEMA E-Box. Teknisk rapport, AGEMA 1999. (Emittance measurements using AGEMA E-Box. Technical report, AGEMA 1999.) 10. Matteï, S., Tang-Kwor, E: Emissivity measurements for Nextel Velvet coating 811-21 between –36°C AND 82°C. 11. Lohrengel & Todtenhaupt (1996) 12. ITC Technical publication 32. 13. ITC Technical publication 29. 14. Schuster, Norbert and Kolobrodov, Valentin G. Infrarotthermographie. Berlin: Wiley- VCH, 2000.

39.2 Tables

Table 39.1 T: Total spectrum; SW: 2–5 µm; LW: 8–14 µm, LLW: 6.5–20 µm; 1: Material; 2: Specification; 3: Temperature in °C; 4: Spectrum; 5: Emissivity: 6:Reference

1 2 3 4 5 6

3M type 35 Vinyl electrical tape (several colors)

< 80 LW ≈0.96 13

3M type 88 Black vinyl electri- cal tape

< 105 LW ≈0.96 13

3M type 88 Black vinyl electri- cal tape

< 105 MW < 0.96 13

3M type Super 33 +

Black vinyl electri- cal tape

< 80 LW ≈0.96 13

Aluminum anodized sheet 100 T 0.55 2

Aluminum anodized, black, dull

70 SW 0.67 9

Page 263 of the Flir T1020 user manual — Emissivity tables 39
Page 263 · click to enlarge
Page 263

Emissivity tables 39

Table 39.1 T: Total spectrum; SW: 2–5 µm; LW: 8–14 µm, LLW: 6.5–20 µm; 1: Material; 2: Specification; 3: Temperature in °C; 4: Spectrum; 5: Emissivity: 6:Reference (continued)

Flir T1020 — Emissivity tables 39 diagram (page 263)
Fig. 128 · Emissivity tables 39
Page 264 of the Flir T1020 user manual — Emissivity tables 39
Page 264 · click to enlarge
Page 264

Emissivity tables 39

Table 39.1 T: Total spectrum; SW: 2–5 µm; LW: 8–14 µm, LLW: 6.5–20 µm; 1: Material; 2: Specification; 3: Temperature in °C; 4: Spectrum; 5: Emissivity: 6:Reference (continued)

Flir T1020 — Emissivity tables 39 diagram (page 264)
Fig. 129 · Emissivity tables 39

Brick silica, 95% SiO2 1230 T 0.66 1

Brick sillimanite, 33% SiO2, 64% Al2O3

Page 265 of the Flir T1020 user manual — Emissivity tables 39
Page 265 · click to enlarge
Page 265

Emissivity tables 39

Table 39.1 T: Total spectrum; SW: 2–5 µm; LW: 8–14 µm, LLW: 6.5–20 µm; 1: Material; 2: Specification; 3: Temperature in °C; 4: Spectrum; 5: Emissivity: 6:Reference (continued)

Flir T1020 — Emissivity tables 39 diagram (page 265)
Fig. 130 · Emissivity tables 39
Page 266 of the Flir T1020 user manual — Emissivity tables 39
Page 266 · click to enlarge
Page 266

Emissivity tables 39

Table 39.1 T: Total spectrum; SW: 2–5 µm; LW: 8–14 µm, LLW: 6.5–20 µm; 1: Material; 2: Specification; 3: Temperature in °C; 4: Spectrum; 5: Emissivity: 6:Reference (continued)

Flir T1020 — Emissivity tables 39 diagram (page 266)
Fig. 131 · Emissivity tables 39

Iron and steel cold rolled 70 SW 0.20 9

Iron and steel cold rolled 70 LW 0.09 9

Iron and steel ground sheet 950–1100 T 0.55–0.61 1

Iron and steel hot rolled 130 T 0.60 1

Iron and steel hot rolled 20 T 0.77 1

Page 267 of the Flir T1020 user manual — Emissivity tables 39
Page 267 · click to enlarge
Page 267

Emissivity tables 39

Table 39.1 T: Total spectrum; SW: 2–5 µm; LW: 8–14 µm, LLW: 6.5–20 µm; 1: Material; 2: Specification; 3: Temperature in °C; 4: Spectrum; 5: Emissivity: 6:Reference (continued)

Flir T1020 — Emissivity tables 39 diagram (page 267)
Fig. 132 · Emissivity tables 39

Iron and steel oxidized strongly 50 T 0.88 1

Iron and steel oxidized strongly 500 T 0.98 1

Iron and steel polished sheet 750–1050 T 0.52–0.56 1

Iron and steel rolled sheet 50 T 0.56 1

Iron and steel rolled, freshly 20 T 0.24 1

Iron and steel rusted red, sheet 22 T 0.69 4

Iron and steel rusted, heavily 17 SW 0.96 5

Iron and steel rusty, red 20 T 0.69 1

Iron and steel shiny, etched 150 T 0.16 1

Iron, cast oxidized at 600°C 200–600 T 0.64–0.78 1

Page 268 of the Flir T1020 user manual — Emissivity tables 39
Page 268 · click to enlarge
Page 268

Emissivity tables 39

Table 39.1 T: Total spectrum; SW: 2–5 µm; LW: 8–14 µm, LLW: 6.5–20 µm; 1: Material; 2: Specification; 3: Temperature in °C; 4: Spectrum; 5: Emissivity: 6:Reference (continued)

Flir T1020 — Emissivity tables 39 diagram (page 268)
Fig. 133 · Emissivity tables 39

Nextel Velvet 811- 21 Black Flat black –60–150 LW > 0.97 10 and 11

Page 269 of the Flir T1020 user manual — Emissivity tables 39
Page 269 · click to enlarge
Page 269

Emissivity tables 39

Table 39.1 T: Total spectrum; SW: 2–5 µm; LW: 8–14 µm, LLW: 6.5–20 µm; 1: Material; 2: Specification; 3: Temperature in °C; 4: Spectrum; 5: Emissivity: 6:Reference (continued)

Flir T1020 — Emissivity tables 39 diagram (page 269)
Fig. 134 · Emissivity tables 39

Oil, lubricating 0.025 mm film 20 T 0.27 2

Oil, lubricating 0.050 mm film 20 T 0.46 2

Oil, lubricating 0.125 mm film 20 T 0.72 2

Oil, lubricating film on Ni base: Ni base only

Page 270 of the Flir T1020 user manual — Emissivity tables 39
Page 270 · click to enlarge
Page 270

Emissivity tables 39

Table 39.1 T: Total spectrum; SW: 2–5 µm; LW: 8–14 µm, LLW: 6.5–20 µm; 1: Material; 2: Specification; 3: Temperature in °C; 4: Spectrum; 5: Emissivity: 6:Reference (continued)

Flir T1020 — Emissivity tables 39 diagram (page 270)
Fig. 135 · Emissivity tables 39
Page 271 of the Flir T1020 user manual — Emissivity tables 39
Page 271 · click to enlarge
Page 271

Emissivity tables 39

Table 39.1 T: Total spectrum; SW: 2–5 µm; LW: 8–14 µm, LLW: 6.5–20 µm; 1: Material; 2: Specification; 3: Temperature in °C; 4: Spectrum; 5: Emissivity: 6:Reference (continued)

Flir T1020 — Emissivity tables 39 diagram (page 271)
Fig. 136 · Emissivity tables 39
Page 272 of the Flir T1020 user manual — Emissivity tables 39
Page 272 · click to enlarge
Page 272

Emissivity tables 39

Table 39.1 T: Total spectrum; SW: 2–5 µm; LW: 8–14 µm, LLW: 6.5–20 µm; 1: Material; 2: Specification; 3: Temperature in °C; 4: Spectrum; 5: Emissivity: 6:Reference (continued)

Flir T1020 — Emissivity tables 39 diagram (page 272)
Fig. 137 · Emissivity tables 39

Stainless steel type 18-8, buffed 20 T 0.16 2

Page 273 of the Flir T1020 user manual — Emissivity tables 39
Page 273 · click to enlarge
Page 273

Emissivity tables 39

Table 39.1 T: Total spectrum; SW: 2–5 µm; LW: 8–14 µm, LLW: 6.5–20 µm; 1: Material; 2: Specification; 3: Temperature in °C; 4: Spectrum; 5: Emissivity: 6:Reference (continued)

Flir T1020 — Emissivity tables 39 diagram (page 273)
Fig. 138 · Emissivity tables 39
Page 274 of the Flir T1020 user manual — 39 Emissivity tables
Page 274 · click to enlarge
Page 274

A note on the technical production of this publication This publication was produced using XML — the eXtensible Markup Language. For more information about XML, please visit http://www.w3.org/XML/

A note on the typeface used in this publication This publication was typeset using Linotype Helvetica™World. Helvetica™was designed by Max Miedinger (1910–1980)

LOEF (List Of Effective Files) T501131.xml; en-US; AL; 37426; 2016-09-22 T505864.xml; en-US; 26038; 2015-05-27 T505469.xml; en-US; 23215; 2015-02-19 T505013.xml; en-US; 35155; 2016-04-21 T505819.xml; en-US; 29249; 2015-10-09 T505889.xml; en-US; 32182; 2016-01-13 T505821.xml; en-US; 32186; 2016-01-13 T505822.xml; en-US; 32182; 2016-01-13 T505823.xml; en-US; 32182; 2016-01-13 T505824.xml; en-US; 32182; 2016-01-13 T505825.xml; en-US; 32182; 2016-01-13 T505826.xml; en-US; 32182; 2016-01-13 T505827.xml; en-US; 32521; 2016-01-19 T505657.xml; en-US; 37264; 2016-09-16 T505658.xml; en-US; 37152; 2016-09-08 T505659.xml; en-US; 32063; 2016-01-08 T505829.xml; en-US; 32182; 2016-01-13 T505661.xml; en-US; 32047; 2016-01-08 T505662.xml; en-US; 37153; 2016-09-08 T505765.xml; en-US; 29249; 2015-10-09 T505880.xml; en-US; 29249; 2015-10-09 T505881.xml; en-US; 29249; 2015-10-09 T505831.xml; en-US; 32182; 2016-01-13 T505853.xml; en-US; 34249; 2016-03-09 T505476.xml; en-US; 11926; 2014-02-20 T505012.xml; en-US; 32556; 2016-01-20 T505007.xml; en-US; 35155; 2016-04-21 T505004.xml; en-US; 35155; 2016-04-21 T505000.xml; en-US; 35155; 2016-04-21 T505005.xml; en-US; 35155; 2016-04-21 T505001.xml; en-US; 32554; 2016-01-20 T505006.xml; en-US; 32555; 2016-01-20 T505002.xml; en-US; 33518; 2016-02-18

Page 275 of the Flir T1020 user manual — 39 Emissivity tables
Page 275 · click to enlarge
Page 275
Page 275 of the Flir T1020 user manual — 39 Emissivity tables
Page 276 of the Flir T1020 user manual — 39 Emissivity tables
Page 276 · click to enlarge
Page 276

Website http://www.flir.com

Customer support http://support.flir.com

Copyright © 2016, FLIR Systems, Inc. All rights reserved worldwide.

Disclaimer Specifications subject to change without further notice. Models and accessories subject to regional market considerations. License procedures may apply. Products described herein may be subject to US Export Regulations. Please refer to exportquestions@flir.com with any questions.

Publ. No.: T559954 Release: AL Commit: 37426 Head: 37426 Language: en-US Modified: 2016-09-22 Formatted: 2016-09-22

last page

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Flir T1020

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Flir T1020

Be the first to ask — other owners or our team will answer.

Original document

Flir T1020 manual PDF

276 pages·27.7 MB·Photo Camera·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…