Aria 2 Product Manual 129-0127-01 Rev C





Welcome to Fitbit Aria 2, the Wireless Smart Scale that uses advanced technology to measure weight, body fat percentage, and body mass index (BMI) to help you take control of your fitness.
The Aria 2 Wireless Smart Scale is a body analyzer that measures body weight and uses bioelectrical impedance analysis (BIA) technology to estimate body fat percentage in generally healthy individuals 13 years of age or older. It is intended for home use only.
Your Fitbit Aria 2 Scale box includes:
We get you started creating a Fitbit® account and making sure your scale can transfer the data it collects to your dashboard. The dashboard is where you may set weight goals, analyze historical data, identify trends, log food and water, keep up with friends, and much more. As soon as you’re done setting up your scale, you’re ready to begin your weigh-ins. To find more information, tips, and troubleshooting, please browse our comprehensive articles at help.fitbit.com.
Your Aria 2 scale is shipped with 3 AA batteries that have been previously installed. Pull the small plastic tab sticking out of the battery compartment to remove the tab and power on your scale.



For the best experience, we recommend pairing your scale to the free Fitbit app, available on iOS, Android, and Windows 10 mobile devices, as well as Bluetooth- enabled Windows 10 computers. Your Fitbit account asks for information such as height, weight, and sex to make various calculations such as basal metabolic rate to estimate calorie burn. Your name is visible to Fitbit friends by default. You have the option to share your age, height, or weight with Fitbit friends, but the information you provide is private by default. Please contact Fitbit Customer Support if assistance is needed in setting up, using, or maintaining the Aria 2 Smart Scale or to report unexpected operations or events.
Aria 2 connects directly to your home’s Wi-Fi network and supports the following network configurations:
Aria 2 requires an 802.11b/g/n-compatible network to connect and sync your scale data to your Fitbit account.
The Fitbit app is compatible with more than 200 devices that support iOS, Android, and Windows 10 operating systems.
To get started, install the app and pair your scale with your mobile device:

Next, connect your scale to your Wi-Fi network:
Other option when selecting a network.
When you’re done connecting to the Wi-Fi network, choose a personalized icon that will appear on your Aria 2’s screen after each use and read through the guide about your new scale.
Now that you’ve linked your scale to your Fitbit account, you’ll want to verify that the scale appears under your devices. Follow these steps to confirm your setup:
If you’ve changed the name, password, router, or provider of your Wi-Fi network, you’ll need to reconnect your Aria 2 to the updated network using the setup method above.
For step-by-step instructions, see help.fitbit.com.

Your Fitbit Aria 2 scale measures your weight, body fat percentage, and BMI. When connected your Fitbit account, measurements from your scale will automatically and privately sync to your dashboard.
Follow these steps to complete a weigh-in on your Aria 2:

Aria 2 will display your weight and body fat measurement. 3. Step off the scale. Aria 2 will automatically send your stats to your dashboard. If you see an error message on your scale, see help.fitbit.com.
After you’ve weighed yourself and your Aria 2 has synced, you can view your data in your dashboard. The dashboard is where you’ll track progress, view your stats including lean mass on a graph, and manually enter or delete a weight.
For more information, see help.fitbit.com.
Up to eight users can sync their Fitbit accounts with a single Aria 2 scale. If someone who does not have an account linked with the scale steps on the scale, only their weight will display (body fat percentage and BMI won’t appear). Registered users will see this weigh-in attributed to “Guest”. For step-by-step instructions, see help.fitbit.com.

If two users on the same scale are close in weight or body composition, your Aria 2 will prompt you to select the correct user noted by their personalized icon. If an incorrect user is chosen, or if a weight is improperly attributed, you can reassign it to the correct user in the Fitbit app or on the fitbit.com website.
For step-by-step instructions, see help.fitbit.com. If your scale consistently recognizes you as a guest, see help.fitbit.com.
“Lean” mode is intended for professional or very high-level athletes like marathon runners or body builders. Individuals with exceptionally low body fat relative to their muscle mass may want to consider lean mode to improve the scale’s accuracy; however, many very fit and active people still get more accurate readings in “Regular” mode, which is appropriate for most users.
For step-by-step instructions, help.fitbit.com.
Use these tips to get the most accurate and consistent readings from your scale:
2 scale has been set up with your Fitbit account. You do not need to complete this setup to weigh yourself.
Factory reset clears all user data from the scale including stored weights and Wi-Fi networks. To factory reset your scale, complete these steps:

1. Turn your scale over and pull up on the tab to remove the cover from the battery compartment. 2. Remove the batteries. 3. Press down on the small button directly above the battery slots. 4. While continuing to press down on the button, reinsert the batteries. Be sure to press down on the button for at least ten seconds. 5. Return the cover to the battery compartment and press down until it’s secure. 6. Turn your scale over to begin the setup process.

Sensors
Four load cells measure weight. Body fat information is measured through electrical impedance and calculated based on weight and user account data.
The scale measures body fat using bioimpedance analysis. Indium tin oxide (ITO) electrodes form a pattern on the top of scale and send a small, safe signal through the body to measure impedance.
To change the batteries in your Aria 2, complete these steps:




Length Width Depth Weight
Aria 2 Scale 12.3in 31.2cm 12.3in 31.2cm 1.3in 31.9mm 4.7lbs. 2.13kg
Operating Temperature 41° to 104° F (5° to 40° C)

Up to 93% RH Aria 2 is designed to operate in a humid bathroom environment.
Storage and Transportation -25°C to 70°C Up to 93% RH Environmental Pressure Range 700kPa to 1060kPa
Ingress Protection IP53: Symbol indicates that the scale is dust and water resistant.
2 scale on a hard, flat surface.
Clean Aria 2 as needed to remove dust and soil. To clean your scale, follow these tips:
Relative Humidity

The scale measures body fat using bioimpedance analysis. ITO electrodes form a pattern on the top of scale, and send a small, safe signal through the body to measure impedance.
Type BF Applied Part
This symbol indicates that the surface scale is a Type BF applied part intended to deliver an electrophysiological signal to and from the user. The scale measures body mass using bioimpedance analysis. ITO electrodes form a pattern on the top of scale, and send a small, safe signal through the body to measure impedance.
Aria 2 is not considered a medical device in all countries below except for the U.S.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
This device may not cause harmful interference and
This device must accept any interference received, including interference that may cause undesired operation
Changes or modifications not approved by Fitbit, Inc. could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
FCC Warning

Dichiarazione di conformità UE semplificata
Fitbit, Inc. dichiara che il tipo di apparecchiatura radio Modello FB202 è conforme alla Direttiva 2014/53/UE. Il testo completo della dichiarazione di conformità UE è disponibile al seguente indirizzo Internet:www.fitbit.com/safety
Fitbit, Inc. erklärt hiermit, dass die Funkgerättypen Modell FB202 die Richtlinie 2014/53/EU erfüllen. Der vollständige Wortlaut der EU-Konformitätserklärungen kann unter folgender Internetadresse abgerufen werden: www.fitbit.com/safety
Declaración UE de Conformidad simplificada
Por la presente, Fitbit, Inc. declara que el tipo de dispositivo de radio Modelo FB202 cumple con la Directiva 2014/53/UE. El texto completo de la declaración de conformidad de la UE está disponible en la siguiente dirección de Internet: www.fitbit.com/safety
This equipment has been tested to comply with safety certification in accordance with the specifications of EN Standard: EN60950-1:2006 + A11:2009 + A1:2010 + A12: 2011 + A2:2013.
The complete Declaration of Conformity can be found at https://www.fitbit.com/legal/safety-instructions
Highest EIRP power in the range (dBm): 19.96
Vereinfachte EU-Konformitätserklärung



.המוצר של המודולארי בחלק טכני שינוי כל לבצע אי









Singapore



클래스 B 장치 (가정 사용을위한 방송 통신 기기) : EMC 등록 주로 가정용 (B 급)으로하고, 모든 지역에서 사용할 수 있습니다
얻을이 장치.
TRA Registered No.: ER56880/17 Dealer No.: 35294/14


Guidance and manufacturer’s declaration – electromagnetic emissions
The Aria 2 Wireless Smart Scale is intended for use in the electromagnetic environment specified below. The customer or the user of the Aria 2 Wireless Smart Scale should assure that it is used in such an environment.
Emissions test Compliance Electromagnetic environment – guidance
RF emissions CISPR 11 Group 1 The Aria 2 Wireless Smart Scale uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.
RF emissions CISPR 11 Class B The Aria 2 Wireless Smart Scale is suitable for use in all establishments other than domestic and those directly connected to the public low- voltage power supply network that supplies buildings used for domestic purposes.
Harmonic emissions IEC 61000-3-2
Voltage fluctuations/flicker emissions IEC 61000-3-3
Guidance and manufacturer’s declaration – electromagnetic immunity
The Aria 2 Wireless Smart Scale is intended for use in the electromagnetic environment specified below. The customer or the user of the Aria 2 Wireless Smart Scale should assure that it is used in such an environment.
Immunity test IEC 60601 test level
Compliance level Electromagnetic environment - guidance
Not Applicable · Not Applicable

± 8 kV contact
± 8 kV contact
Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %.
± 15 kV air
± 15 kV air
± 2 kV for power supply lines
Not applicable Not applicable
± 1 kV for input/output lines
± 1 kV line(s) to line(s)
Not applicable Not applicable
± 2 kV line(s) to earth
Voltage dips and interruptions
0 % UT; 0.5 cycle At 0°, 45°, 90°, 135°, 180°, 225°, 270° and 315°
Not applicable Not applicable
0 % UT; 1 cycle and
70 % UT; 25/30 cycles Single phase: at 0°
0 % UT; 250/300 cycle
Electrostatic Discharge (ESD) · Electrical fast transient/burst · Surge

Power frequency (50/60 Hz) magnetic field
30 A/m 30 A/m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment.
The Aria 2 Wireless Smart Scale has no essential performance per IEC 60601-1-2
In accordance with IEC 60601-1 Aria 2 Wireless Smart Scale users are intended operators and may perform described functions and described maintenance while the device is not in use.
Follow ESD precautions to prevent damage and to protect against potential hazards such as electric shock.
Guidance and manufacturer’s declaration – electromagnetic immunity
The Aria 2 Wireless Smart Scale is intended for use in the electromagnetic environment specified below. The customer or the user of the Aria 2 Wireless Smart Scale should assure that it is used in such an environment.
Immunity test IEC 60601 test level
Electromagnetic environment - guidance
Portable and mobile RF communication equipment should be no closer to any part of the Aria 2 Wireless Smart Scale, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
Compliance level

150 kHz to 80 MHz
d = 1.17* √P 80 MHz to 800 MHz
80 MHz to 2.7 GHz 80% AM at 1kHz
d = 2.33* √P 800 MHz to 2.5 GHz
Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m).
Field strengths from fixed RF transmitters, as determined by an electromagnetic site surveya, should be less than the compliance level in each frequency rangeb.
Interference may occur in the vicinity of equipment marked with the following symbol:

a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Aria 2 Wireless Smart Scale is used exceeds the applicable RF compliance level above, the Aria 2 Wireless Smart Scale should be observed to verify normal operation. If abnormal performance is observed, additional measures maybe necessary, such as re-orienting or relocating the Aria 2 Wireless Smart Scale.
b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Recommended separation distances between portable and mobile RF communication equipment and the Aria 2 Wireless Smart Scale
The Aria 2 Wireless Smart Scale is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the Aria 2 Wireless Smart Scale can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the Aria 2 Wireless Smart Scale as recommended below, according to the maximum output power of the communications equipment.
Separation distance according to frequency of transmitter
Rated maximum output power of transmitter
80 MHz to 800 MHz
800 MHz to 2.5 GHz
150 kHz to 80 MHz
d = 1.17* √P
d = 1.17* √P
d = 2.33* √P
0.01 Not applicable 0.12 0.23
m

0.1 Not applicable 0.37 0.74
1 Not applicable 1.17 2.33
10 Not applicable 3.7 7.37
100 Not applicable 11.7 23.3
For transmitters rated a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
The Aria 2 Wireless Smart Scale complies with the Wireless IEEE 802.11b (CCK/BPSK modulation) operating in the 2400-2483.5MHz band. The effective Radiated Output Power is 25 dBm.
Portable and mobile RF communications equipment can affect the operation of the Aria 2 Wireless Smart Scale, even if that equipment complies with CISPR emissions requirements.
Handle the battery in accordance with the instructions supplied by the manufacturer.
The symbol on the product or its packaging signifies that this product has to be disposed separately from ordinary household wastes at its end of life. Please kindly be aware that this is your responsibility to dispose electronic equipment at recycling centers so as to help conserve natural resources. Each country in the European Union should have its collection centers for electrical and electronic equipment recycling. For information about your recycling drop off area, please contact your local related

Help
Troubleshooting and assistance for your Aria 2 may be found at help.fitbit.com.
Warranty information and the Fitbit.com Store Return Policy may be found at fitbit.com/returns
199 Fremont Street, 14th Floor
San Francisco, CA 94105
Fitbit

©2018 Fitbit, Inc. All rights reserved. Fitbit and the Fitbit logo are trademarks or registered trademarks of Fitbit in the US and other countries. A more complete list of Fitbit trademarks can be found at http://www.fitbit.com/legal/trademark-list Third- party trademarks mentioned are the property of their respective owners.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.