Products Ltd may have a detrimental effect on the detector’s operation. Replace the battery cover and return the detector to its original position.
D Your advanced First Alert CO detector requires a short ‘warm-up’ period before it is fully operational.
Press ridged area in and slide door out to reveal battery compartment
Should you suspect CO may be affecting you or your family, open the doors and windows of your property to ventilate, turn off your appliances and evacuate the premises. At this time the authorities should be contacted to locate the source of the carbon monoxide before re- entering the building. Medical attention should be sought for anyone suffering the effects of CO poisoning (headache, nausea).
EDUCATE YOURSELF AND YOUR FAMILY ON THE SOURCES AND SYMPTOMS OF CO POISONING AND HOW TO USE YOUR CARBON MONOXIDE DETECTOR
If the apparatus is located on the ceiling:
E Test the sounder, batteries and circuitry by pressing and holding the Test/Reset button for 1 second. The sounder should sound as soon as the button is pressed, and the Alarm LED will illuminate red for a short time indicating that the sounder is working and the batteries are providing power to the unit. This test for the sounder, batteries and circuitry should be performed weekly.
Drill hole spacing
DETECTOR
Apparatus located in sleeping rooms and in rooms remote from a fuel burning appliance:
This CO alarm is suitable for use in domestic premises (caravan holiday homes), caravans and motor caravans.
Where not to put the detector
The following advice is applicable to all intended applications, there are special instructions at the end of this section relating to positioning in caravan holiday homes, caravans and motor caravans.
The apparatus should not be installed:
Carbon monoxide is a poisonous gas that kills hundreds of people each year and injures many more. It is often referred to as the silent killer, it has no odour or taste and cannot be seen. Like oxygen, CO enters the body through the lungs during the normal breathing process. It competes with oxygen by replacing it in the red blood cells, thereby reducing the flow of oxygen to the heart, brain and other vital organs. In high concentrations, CO can kill in minutes. Many cases of reported carbon monoxide poisoning indicate that while victims are aware they are not feeling well, they become disorientated and unable to save themselves by either exiting the building or calling for assistance. Exposure during sleep is particularly dangerous because the victim usually does not wake up.
The detector will not protect against the risk of carbon monoxide poisoning when the batteries have drained.
In which room should the detector be installed?
Your First Alert CO detector offers many features which set it apart from other CO detectors on the market today.
This CO detector should not be seen as a substitute for the proper installation, use, and maintenance of fuel-burning appliances (including appropriate ventilation and exhaust systems), nor the sweeping of chimneys.
Ideally, an apparatus should be installed in every room containing a fuel burning appliance. Additional apparatus may be installed to ensure that adequate warning is given for occupants in other rooms, by locating apparatus in:
This button will:
WARNING: : Variables relating to your fuel burning appliances can change at any point eg. the flue or chimney could suddenly become blocked or damaged, appliances may stop running correctly or circumstances in neighbouring properties may change resulting in the presence of carbon monoxide. For this and other reasons do not use this carbon monoxide detector on an intermittent basis, or as a portable detector for trying to trace one source of the spillage of combustion products from fuel burning appliances or from chimney.
Symptoms of CO poisoning The following symptoms may be related to CO poisoning which all household members should be made aware of:
A If the detector is already wall or ceiling mounted then unhook it from the mounting screws.
B Remove the battery cover located on the back of the detector.
Caravans Caravans may have additional risks of carbon monoxide ingress through air vents due to the nearby presence of other vehicles, engines, generators or barbecues, however this does not change the basic guidance on location of the alarm. Caravans should be fitted with an
However, if there is a fuel burning appliance in more than one room and the number of apparatus is limited, the following points should be considered when deciding where best to put the apparatus:
C Replace the batteries with 2 x approved 1.5 volt AA size alkaline batteries, making sure the batteries are the correct way round. Use of batteries other than those recommended by Sprue Safety
Testing the sounder, batteries and circuitry
Test the sounder, batteries and circuitry by pressing and holding the Test/Reset button for 1 second to confirm that the detector is operating
Test/Reset button feature

properly. The sounder should sound as soon as the button is pressed, and the Alarm LED will illuminate red, indicating that the sounder is working and the batteries are providing power to the unit. This test for the sounder, batteries and circuitry should be performed weekly.
DISPOSAL
RETURNS
National Gas Emergency Service 0800 111 999 (24 Hours)
Waste electrical products should not be disposed of with regular household waste.
Should you encounter a problem with your alarm, we recommend that you contact the First Alert Technical Support Line in the first instance for advice on 0800 141 2561 (9.00am–5.00pm, Monday–Friday), UK Text phone users dial 18001 0800 141 2561 or callers from EIRE dial 1-800 523171 as we may be able to remedy the problem quickly over the phone (this is to prevent unnecessary returns that take a longer time to process). Alternatively e-mail:
Please recycle where facilities exist. Check with your local authority, retailer or the First Alert Technical Support Line for recycling/disposal advice as regional variations apply.
To prevent the possibility of contaminating the sensor in your detector and thus affecting its reliability:
Gas Safe register 0800 408 5500
NOTE: We suggest the use of an incense stick or cigarette as the way in which these products burn produces a readable localised amount of carbon monoxide. Alternative sources of smoke, for example an extinguished candle or match, will not contain sufficient levels of carbon monoxide to obtain a response from the detector during this test. Please note your CO detector will not detect smoke.
Solid Fuel Association Advisory service for domestic and solid fuel appliances 0845 601 4406
The batteries should be removed before disposal of the detector. Both the batteries and the detector should be disposed of in line with current regulations.
HETAS Trade association for solid fuel engineers 0845 223 3033
technicalsupport@sprue.com
If there is a fault that we are unable to resolve then our technical support team member will provide you with a returns authority number so that your product can be returned for testing.
OFTEC Trade association for Oil Fired Appliance engineers 0845 658 5080
If testing the sensor for the first time after installation, or replacing the batteries, make sure that the alarm has completed the initial 3 minute warm up period and the power LED is flashing green once every minute.
To return your First Alert CO-FA-9B under warranty, send it suitably packed and with the batteries disconnected with postage prepaid; a note indicating the returns authority number and describing the reason for return, with proof of purchase to:
Sprue Safety Products Ltd warrants to the original purchaser that its enclosed sealed carbon monoxide detector be free from defects in materials and workmanship under normal residential use and service for a period of 7 (seven) years from the date of purchase.
Step 5 After step 4, put out the incense stick or cigarette by placing it into a dish of water. Ensure that all flames have been extinguished.
NACS National Association of Chimney Sweeps 01785 811732
IPHE Institute of Plumbing and Heating Engineers 01708 472791
This test should be performed annually.
Sprue Safety Products Ltd. First Alert Customer Services 6 Davy Way, Carter Court Waterwells Business Park Gloucester GL2 2DE United Kingdom
Provided it is returned with postage prepaid and proof of purchase, Sprue Safety Products Ltd hereby warrants that during the 7 (seven) year period commencing from the date of purchase Sprue Safety Products Ltd, at its discretion, agrees to replace the unit free of charge. The warranty on any replacement First Alert CO-FA-9B Carbon Monoxide Poisonous Gas Alarm will last for the remainder of the period of the original warranty in respect of the detector originally purchased – that is from the date of original purchase and not from the date of receipt of the replacement product. Sprue Safety Products Ltd reserves the right to offer an alternative product similar to that being replaced if the original model is no longer available or in stock. This warranty applies to the original retail purchaser from the date of original retail purchase and is not transferable. Proof of purchase is required.
TECHNICAL INFORMATION
Failure of any test should be reported to the First Alert technical support.
The higher the concentration of carbon monoxide detected by the detector, the quicker it will respond. When sufficient carbon monoxide is detected a loud audible signal (85 dB at 1m/3 feet) will be emitted and the Alarm LED will flash red once every second.
Do not attempt to repair your CO detector. Do not remove any screws or open the main casing of your detector. Any attempt to do so may cause malfunction and will invalidate the warranty.
Sprue Safety Products Ltd manufactures an extensive range of home safety products including smoke alarms, carbon monoxide detectors, fire extinguishers and remote sounding devices. For more details visit www.sprue.com
Step 1 If the detector is wall or ceiling mounted unhook the detector from the screws.
Step 2 Cover the sounder vents with one hand. Press and hold the Test/Reset button down with your thumb/finger until the Power LED illuminates green and the sounder sounds for a second time (this should happen after around 5 seconds). Release the Test/Reset button. Upon releasing the Test/Reset button the Power LED will flash green once every second. This indicates that the sampling rate of the detector has increased and can be tested using a known source of CO.
The Alarm will sound:
Technical Support Line 0800 141 2561
UK Textphone users dial 18001 0800 141 2561
EIRE dial 1-800 523171
Fault / low battery signal:
The unit continuously checks the settings of its sensor and circuitry. If any of these settings are found to be incorrect or if the batteries become low then the detector will emit a single audible chirp once per minute for up to 30 days. IMPORTANT: This does NOT mean that the detector has detected carbon monoxide.
This warranty does not cover damage resulting from accident, misuse, disassembly, abuse or lack of reasonable care of the product, or applications not in accordance with the user manual. It does not cover events and conditions outside of Sprue Safety Products Ltd’s control, such as Acts of God (fire, severe weather etc). It does not apply to retail stores, service centres or any distributors or agents. Sprue Safety Products Ltd will not recognise any changes to this warranty by third parties. Sprue Safety Products Ltd shall not be liable for any incidental or consequential damages caused by the breach of any expressed or implied warranty. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to 7 years.
Email technicalsupport@sprue.com
Please carefully review this owner’s manual to ensure that you know what actions to take in the event of an alarm.
Web www.sprue.com
What to do during an alarm
Replace batteries immediately. If the product continues to chirp despite having new batteries and the product is still within warranty then contact technical support for advice. If the product is no longer in warranty replace it immediately!
This First Alert carbon monoxide detector is designed to continuously monitor for CO. Its response times meet the requirements of the European standard EN 50291-1: 2010 and EN 50291-2: 2010.
Step 3 Light an incense stick or cigarette using a match or lighter. If using an incense stick be sure to blow out the flame so that the incense stick is smouldering. Extinguish the lighter, or put out the match and place it into a dish of water.
First Alert Technical Support Line
9.00am–5.00pm, Monday–Friday.
The alarm will sound:
Write your fuel supplier’s emergency number here (see opposite for more useful numbers):
This warranty does not affect your statutory rights. Except for death or personal injury, Sprue Safety Products Ltd shall not be liable for any loss of use, damage, cost or expense relating to this product or for any indirect, or consequential loss, damages or costs incurred by you or any other user of this product.
Step 4 Turn the detector on its side so that the vents on the right hand side of the detector are pointing downwards (see diagram above). Hold the burning incense stick or cigarette around 15cm (6 inches) below the detector, so that the smoke enters the vents on the side of the detector. An increase in the localised carbon monoxide level within the sensor to more than 50ppm will cause the sounder to sound for one cycle of four loud beeps and the Power LED to illuminate green for a short time. This is the end of the test. The Power LED will no longer flash green every second but will revert to flashing once every minute as the detector will go back to normal operating mode (It may take up to two minutes of exposure to the smoke for the localised level of carbon monoxide within the sensor to reach over 50ppm). Now move the source of CO away from the detector as the test is finished.
MAINTAINING / TESTING
YOUR DETECTOR
The warranty does not cover the batteries which are considered user-replaceable parts.
Your detector will alert you to potentially hazardous CO concentrations in your home when maintained properly. To maintain your First Alert detector in proper working order, and to ensure that the sensor will last for the lifetime of the product, it is recommended that you:
A CARBON MONOXIDE DETECTOR IS NOT A SUBSTITUTE FOR A SMOKE ALARM OR A COMBUSTIBLE GAS DETECTOR.
REPLACE UNIT AFTER 7 YEARS OF OPERATION.
A Sprue Safety Products Brand
Sprue Safety Products Ltd.
Vanguard Centre Sir William Lyons Road Coventry CV4 7EZ UK