EN
Falmec logo
Official user manual

Falmec Alba

88 pages·6.6 MB·Kitchen Range Hood·PDF·ENJA
Falmec Alba
Table of Contents 45 sections falmec.com · INSTRUCTIONS BOOKLET · Alba · IT LIBRETTO ISTRUZIONI · … ShowHide
Page 1 of the Falmec Alba user manual — IT LIBRETTO ISTRUZIONI
Page 1 · click to enlarge
Page 1

falmec.com

INSTRUCTIONS BOOKLET

Falmec Alba — falmec.com diagram (page 1)
Fig. 1 · falmec.com

Alba

IT LIBRETTO ISTRUZIONI

EN INSTRUCTIONS BOOKLET

DE GEBRAUCHSANWEISUNG

FR MODE D'EMPLOI

ES MANUAL DE INSTRUCCIONES

PL INSTRUKCJA OBSŁUGI

NL HANDLEIDING

MADE IN VITTORIO VENETO (TV) - ITALY

PT MANUAL DE INSTRUÇÕES

DK BRUGSANIVSNINGER

SE INSTRUKTIONSBOK

FI OHJEKIRJA

NO BRUKSANVISNING

RU ɂɇɋɌɊɍɄɐɂɂ

Page 2 of the Falmec Alba user manual — falmec.com
Page 2 · click to enlarge
Page 2

IT - Installazione con motore sulla cappa.

11 PT - Instalação com motor na capa.

EN - Installation with motor on the hood.

DK - Installation med motoren på emhætten.

DE - Installation mit Motor an der Haube.

SE - Installation med motor på fläkthuven.

FR - Installation avec moteur sur la hotte.

FI - Asennus moottori liesituulettimen päällä.

ES - Instalación con el motor en la campana.

NO - Installasjon med motor på hetten.

Falmec Alba — falmec.com diagram (page 2)
Fig. 2 · falmec.com
Page 3 of the Falmec Alba user manual — falmec.com
Page 3 · click to enlarge
Page 3

IT - Installazione con motore SLIM.

PT - Instalação com motor SLIM.

EN - Installation with SLIM motor.

DK - Installation med motoren SLIM.

DE - Installation SLIM-Motor.

SE - Installation med SLIM-motor.

FR - Installation avec moteur SLIM.

FI - Asennus SLIM-moottorilla.

Falmec Alba — falmec.com diagram (page 3)
Fig. 3 · falmec.com
Page 4 of the Falmec Alba user manual — PL - Instalacja z zestawem dopro-
Page 4 · click to enlarge
Page 4

IT - Installazione con kit convo-

RU - Установка с комплектом воз-

19 SE - Installation med transpor-

gliatore e motore remoto.

духовода и удаленным дви- гателем.

törsats och separat monte- rad motor.

EN - Installation with conveyor

kit and remote motor.

PL - Instalacja z zestawem dopro-

FI - Asennus kanavasarjalla ja

wadzającym i silnikiem ze- wnętrznym.

etäkäyttömoottorilla.

Falmec Alba — PL - Instalacja z zestawem dopro- diagram (page 4)
Fig. 4 · PL - Instalacja z zestawem dopro-
Page 5 of the Falmec Alba user manual — PL - Instalacja z zestawem dopro-
Page 5 · click to enlarge
Page 5

IT - Installazione con kit convo-

RU - Установка с комплектом воз-

21 SE - Installation med transpor-

gliatore e motore remoto.

духовода и удаленным дви- гателем.

törsats och separat monte- rad motor.

EN - Installation with conveyor

kit and remote motor.

PL - Instalacja z zestawem dopro-

FI - Asennus kanavasarjalla ja

wadzającym i silnikiem ze- wnętrznym.

etäkäyttömoottorilla.

Falmec Alba — PL - Instalacja z zestawem dopro- diagram (page 5)
Fig. 5 · PL - Instalacja z zestawem dopro-
Page 6 of the Falmec Alba user manual — 21 SE - Installation med transpor-
Page 6 · click to enlarge
Page 6

IT - Installazione con motore remoto.

23 PT - Instalação com motor remoto.

EN - Installation with remote motor.

DK - Installation med fjernmotor.

DE - Installation mit getrennt montiertem Motor.

SE - Installation med separat monterad motor.

FR - Installation avec moteur à distance.

FI - Asennus etäkäyttömoottorilla.

Falmec Alba — 21 SE - Installation med transpor- diagram (page 6)
Fig. 6 · 21 SE - Installation med transpor-
Page 7 of the Falmec Alba user manual — 21 SE - Installation med transpor-
Page 7 · click to enlarge
Page 7
Falmec Alba — 21 SE - Installation med transpor- diagram (page 7)
Fig. 7 · 21 SE - Installation med transpor-
Page 8 of the Falmec Alba user manual — 21 SE - Installation med transpor-
Page 8 · click to enlarge
Page 8
Falmec Alba — 21 SE - Installation med transpor- diagram (page 8)
Fig. 8 · 21 SE - Installation med transpor-

DE - Vorbereitende Arbeiten: Schnitt Gipskar- ton (1), Einsetzung Halterungsrahmen (2).

de plâtre (1), insertion d'un cadre de support (2).

ning in de gipsplaat (1) en breng de steunlijst (2) aan.

Page 9 of the Falmec Alba user manual — USER WARNINGS
Page 9 · click to enlarge
Page 9

SAFETY INSTRUCTIONS AND WARNINGS

ELECTRICAL SAFETY

The electrical system to which the hood is to be connected must be in accordance with local standards and supplied with earthed connection in compliance with safety regulations in the country of use. It must also comply with European standards regarding radio antistatic properties.

Installation operations are to be carried out by skilled and qualified installers in ac- cordance with the instructions in this book- let and in compliance with the regulations in force. DO NOT use the hood if the power supply cable or other components are damaged: disconnect the hood from the electrical power supply and con- tact the Dealer or an authorised Servicing Dealer for repairs. Do not modify the electrical, mechanical or func- tional structure of the equipment. Do not personally try to carry out repairs or re- placements. Interventions carried out by incom- petent and unauthorised persons can cause seri- ous damage to the unit or physical and personal harm, not covered by the Manufacturer's warran- ty.

ENGLISH

Before installing the hood, check that the electrical mains power supply corresponds with what is report- ed on the identification plate located inside the hood.

The socket used to connect the installed equipment to the electrical power supply must be within reach: otherwise, install a mains switch to disconnect the hood when required.

Any changes to the electrical system must be carried out by a qualified electrician.

The maximum length of the flue fastening screws (supplied by the manufacturer) must be 13 mm. Use of non-compliant screws with these instructions can lead to danger of an electrical nature.

WARNINGS FOR THE INSTALLER

TECHNICAL SAFETY

Do not try to solve the problem yourself in the event of equipment malfunction, but contact the Dealer or an authorised Servicing Department for repairs.

Before installing the hood, check the integ- rity and function of each part. Should anomalies be noted, do not proceed with installation and contact the Dealer.

When installing the hood, disconnect the equipment by removing the plug or switching off the main switch.

Do NOT install the hood if an aesthetic (or cos- metic) defect has been detected. Put it back into its original package and contact the dealer. No claim can be made for aesthetic (or cosmetic) defects once it has been installed. During installation, always use personal protective equipment (e.g.: Safety shoes) and adopt prudent and proper conduct. The installation kit (screws and plugs) supplied with the hood is only to be used on masonry walls: in case of installation on walls of a different material, assess other installation options keeping in mind the type of wall surface and the weight of the hood (indicated on page 2). Keep in mind that installations with different types of fastening systems from those supplied, or which are not compliant, can cause electrical and mechanical seal danger. Do not install the hood outdoors and do not expose it to atmospheric elements (rain, wind, etc.).

FUMES DISCHARGE SAFETY

Do no connect the equipment to discharge pipes of fumes produced from combustion (for example boilers, fireplaces, etc.).

Before installing the hood, ensure that all standards in force regarding discharge of air out of the room have been complied with.

USER WARNINGS

These warnings have been drawn up for your personal safety and those of others. You are therefore kindly asked to read the booklet carefully in its entirety before using the or cleaning the equipment. The Manufacturer declines all responsibility for any damage caused directly, or indirectly, to per- sons, things and pets as a consequence of failing to comply with the safety warnings indicated in this booklet.

Page 10 of the Falmec Alba user manual — ELECTRICAL CONNECTION (only intended for qualified personnel)
Page 10 · click to enlarge
Page 10

It is imperative that this instructions booklet is kept together with the equipment for any future consultation. If the equipment is sold or transferred to another per- son, make sure that the booklet is also supplied so that the new user can be made aware of the hood's operation and relative warnings. After the stainless steel hood has been installed, it will need to be cleaned to remove any residues re- maining from the protection adhesive as well as any grease and oil stains which, if not removed, can cause irreversible damage to the hood surface. To properly clean the unit, the manufacturer recommends using the supplied moist wipes, which are also available sold separately.

equipment and compromise its operation. Accessible parts of the hood can be hot when used at the same time as the cooking appliances. Do not carry out any cleaning operations when parts of the hood are still hot. There can be a risk of fire if cleaning is not carried out according to the instructions and products indicated in this booklet. Disconnect the main switch when the equipment is not used for long periods of time.

If other appliances that use gas or other fu- els are being used at the same time (boiler, stove, fireplaces, etc.), make sure the room where the fumes are discharged is well-ventilat- ed, in compliance with the local regulations.

Insist on original spare parts.

INTENDED USE The equipment is solely intended to be used to extract fumes generated from cooking food in non-professional domestic kitchens: any other use is improper. Improper use can cause damage to persons, things, pets and exempts the Manu- facturer from any liability.

INSTALLATION only intended for qualified personnel

Before installing the hood, carefully read the chapter 'SAFETY INSTRUCTIONS AND WARNINGS'.

TECHNICAL FEATURES The technical specifications are exhibited on the labels located inside the hood.

The equipment can be used by children over the age of 8 and by persons with reduced physical, sensory and mental abilities, or with no experience or knowl- edge, as long as they do so under supervision or after having received relative instructions regarding safe use of the equipment and understanding of the dan- gers connected to it. Children are not to play with the equipment. Clean- ing and maintenance by the user must not be carried out by children without supervision.

POSITIONING The minimum distance between the highest part of the cooking equip- ment and the lowest part of the hood is indicated in the installation in- structions. Generally, when the hood is placed over gas cookers, the distance must be at least 65 cm (25.6''). However, according to an interpretation of standard EN60335-2-31 dated 11-07-2002 of TC61 (sub-clause 7.12.1 meeting 15 agenda item 10.11), the minimum distance between the cooker and lower part of the hood can be reduced to the quota reported in the installation instructions. Should the instructions for the gas cooker specify a greater distance, this must be taken into consideration. Do not install the hood outdoors and do not expose it to outdoor environment (rain, wind, etc.).

USE AND CLEANING WARNINGS

Before cleaning or carrying out mainte- nance operations, disconnect the equip- ment by removing the plug or switching off the main switch.

ELECTRICAL CONNECTION (only intended for qualified personnel)

Disconnect the equipment from electrical mains power supply be- fore carrying out any operations on the hood. Ensure that the wires inside the hood are not disconnected or cut: in the event of damage, contact your nearest Servicing Department. Refer to qualified personnel for electrical connections. Connection must be carried out in compliance with the provisions of law in force. Before connecting the hood to the electrical mains power supply, check that: • voltage supply corresponds with what is reported on the data plate located inside the hood;

Do not use the hood with wet hands or bare feet. Always check that all electrical parts (lights, extractor fan) are off when the equipment is not being used. The maximum overall weight of any objects placed or hung (if applicable) on the hood must not exceed 1.5 Kg. Always supervise the cooking process during the use of deep-fryers: Overheated oil can catch fire. Do not leave open, unattended flames under the hood. Do not prepare food over an open flame under the hood. Never use the hood without the metal anti-grease filters: in this case, grease and dirt will deposit in the

  • the electrical system is compliant and can withstand the load (see the technical specifications located inside the hood);
  • the power supply plug and cable do not come into contact with temperatures exceeding 70 °C;
  • the power supply system is effectively and properly connected to earth in compliance with regulations in force;
  • the socket used to connect the hood is within reach.

In case of: • devices fitted with cables without a plug: the type of plug to use is a ''stand- ardised'' one. The wires must be connected as follows: yellow-green for earth- ing, blue for neutral and brown for the phase. The plug must be connected to an adequate safety socket.

Page 11 of the Falmec Alba user manual — OPERATION
Page 11 · click to enlarge
Page 11
  • fixed equipment not provided with a power supply cable and plug, or any other device that ensures disconnection from the electrical mains, with an opening gap of the contacts that enables total disconnection in overvoltage category III conditions.

ELECTRONIC PUSHBUTTON PANEL

Falmec Alba — ELECTRONIC PUSHBUTTON PANEL diagram (page 11)
Fig. 9

Said disconnection devices must be provided in the mains power supply in compliance with installation regulations.

The yellow/green earth cable must not be cut off by the switch. The Manufacturer declines all responsibility for failure to comply with the safety regulations.

ENGLISH

Motor ON/OFF Upon start-up, the speed is that stored at the previous operation.

The speeds are indicated by the LEDs on the keys:

FUMES DISCHARGE

Increase speed from 1 to 4 Speed 4 is only active for a few minutes, then speed 3 activates.

EXTERNAL EXHAUST HOOD (SUCTION)

In this version the fumes and vapours are discharged outside through the exhaust pipe. To this end, the hood outlet fitting must be connected via a pipe, to an external output.

  • The outlet pipe must have:
  • a diameter not less than that of the hood fitting.
  • a slight slope downwards (drop) in the horizontal sections to prevent condensation from flowing back into the motor.
  • the minimum required number of bends.
  • the minimum required length to avoid vibrations and reduce the suction performance of the hood. You are required to insulate the pipes if it passes through cold environments. In the presence of motors with 800m 3 /h or higher, a check valve is present to

TIMER (red LED flashing) Auto switch-off after 15 min. The function deactivates (red LED off) if: - The TIMER key ( ) is pressed again. - The ON/OFF key ( ) is pressed.

prevent external air flowing back.

USING THE RADIO CONTROL

Deviation for Germany: when the kitchen hood is used at the same time as appliances that are powered by energy other than electricity, the negative pressure in the room must not exceed 4 Pa (4 x 10-5 bar).

WARNINGS!: Place the hood away from sources of electromagnetic waves (e.g. microwave ovens), which could interfere with the radio control and with the hood electronics. The maximum operating distance is 5 metres, that may vary according to the presence of electromagnetic interferences. Radio control operated at 433.92MHz. The radio control consists of two parts: - the receiver built into the hood; - the transmitter shown here in the figure.

HOOD WITH INTERNAL RECIRCULATION (FILTERING)

In this model, the air passes through the charcoal filters to be purified and recycled in the environment.

Ensure that the active carbon filters are assembled into the hood, if not, install them as indicated in the assembly instruc- tions.

DESCRIPTION OF TRANSMITTING COMMANDS

In this version the check valve must not be assembled: remove it if it is on the air outlet fitting of the motor.

UP Motor switch-on and speed increase from 1 to 4. Speed 4 is only active for a few minutes.

ASSEMBLY INSTRUCTIONS only intended for personnel qualified

DOWN Speed decrease and motor switch-off.

The hood can be installed in various configurations. The generic assembly steps apply to all installations; for each case, follow the specific steps provided for the required installation.

Light ON-OFF Short impulseturn light on and off Long impulse: change light tone from 2700K to 5600K

OPERATION

TIMER ONThe motor automatically switches off after 15 min. The function is automatically disabled

WHEN TO TURN ON THE HOOD? Switch on the hood at least one minute before starting to cook to direct fumes and vapours towards the suction surface. After cooking, leave the hood operating until complete extraction of all vapours and odours. By means of the Timer function, it is possible to set auto switch-off function which will allow the hood to turn off automatically after 15 minutes of operation.

if the motor is switched off ( key)

  • ACTIVATION PROCEDURE Before using the radio control, follow the procedure below on the hood pushbutton panel:
  • Press LIGHT ( ) and TIMER ( ) simultaneously until all LEDs start flashing.
  • Release the two keys and press LIGHT ( ) again until all LEDs are lit up.
  • Release LIGHT ( ): now the receiver is active. This procedure is also used to deactivate the receiver.

WHICH SPEED IS TO BE SELECTED? 1st speed: maintains the circulation of clean air with low electricity consump- tion. 2nd speed: normal conditions of use. 3rd speed: presence of strong odours and vapours. 4th speed: rapid disposal of odours and vapours.

WHEN SHOULD THE FILTERS BE WASHED OR REPLACED? The metal filters must be cleaned every 30 hours of operation. The active carbon filters must be replaced every 3-4 months, depending on the use of the hood. For further details see the “MAINTENANCE” chap.

RADIO CONTROL CODE CHANGE With only one radio control, go directly to point 2. With several radio controls in the same room, a new code can be created by following the procedure below.

Command transmission active

Page 12 of the Falmec Alba user manual — CLEANING OF INTERNAL SURFACES
Page 12 · click to enlarge
Page 12

METAL ANTI-GREASE FILTERS It is advised to frequently wash the metal filters (at least once a month) leaving them to soak in boiling water and cleaning solution for 1 hour, taking care not to bend them. Do not use corrosive, acid or alkaline detergents. Rinse them well and wait for them to be completely dry before reassembling them. Washing in a dishwasher is permitted, however, it may cause the filter material to darken: to reduce the possibility of this problem from happening, use low-tem- perature washes (55°C max.). To extract and insert the metal anti-grease filters see the assembly instructions.

Disconnect the power to the hood before starting the procedure.

1. - CREATE A NEW CODE The procedure is to be carried out on the radio control.
  • Press LIGHT and TIMER simultaneously until the display starts flashing.
  • Press DOWN on the radio control: saving is confirmed by three brief flashes of the display. The new code cancels and replaces the previous default code.

Reconnect the hood to the electrical power supply, making sure that the lights and motor are off.

ACTIVE CARBON FILTERS These filters retain the odours in the air that passes through them. The purified air is recirculated into the environment. The active carbon filters must be replaced on average every 3-4 months under normal conditions of use. See assembly instructions to replace the active carbon filters.

2. - ASSOCIATING THE RADIO CONTROL WITH THE HOOD USING THE ELECTRONIC PUSHBUTTON PANEL press TIMER ( ) on the hood pushbutton panel for 2 seconds: the red LED lights up. press any key on the radio control within 10 seconds.

RESTORING DEFAULT CODE the procedure is to be carried out if the hood is disposed of, sold or transferred.

LIGHTING The range hood is equipped with high efficiency, low consumption LED with extremely long duration under normal use conditions. Should replacement be required, contact a service centre.

Disconnect the power to the hood before starting the procedure.

  • Press UP and DOWN simultaneously on the radio control for more than 5 seconds: reset is confirmed by three brief flashes of the display.
  • Reconnect the hood to the electrical power supply.
  • Proceed with associating the hood and the radio control, as described in point 2.

DISPOSAL AFTER END OF USEFUL LIFE

MAINTENANCE

The crossed-out trash or refuse bin symbol on the appliance means that the product is WEEE, i.e. “Waste electrical and electronic equip- ment'', accordingly it must not be disposed of with regular unsort- ed waste (i.e. with ''mixed household waste''), but it must be disposed of sepa- rately so that it can undergo specific processing for its re-use, or a specific treatment, to remove and safely dispose of any substances that may be harmful to the environment and remove the raw materials that can be recycled. Proper disposal of these products contributes to saving valuable resources and avoid potential negative effects on personal health and the environment, which may be caused by inappropriate disposal of waste. You are kindly asked to contact your local authorities for further information regarding the designated waste collection points nearest to you. Penalties for improper disposal of such waste can be applied in compliance with national regulations.

Before cleaning or carrying out maintenance operations, discon- nect the equipment by removing the plug or switching off the main switch. Do not use detergents containing abrasive, acidic or corrosive substances or abrasive cloths. Regular maintenance guarantees proper operation and performance over time. Special attention is to be paid to the metal anti-grease filters : frequent clean- ing of the filters and their supports ensures that no flammable grease is accu- mulated.

CLEANING OF EXTERNAL SURFACES You are advised to clean the external surfaces of the hood at least once every 15 days to prevent oily substances and grease from sticking to them. To clean the brushed stainless steel hood, the Manufacturer recommends using "Magic Steel" wipes. Alternatively and for all the other types of surfaces, it can be cleaned using a damp cloth, slightly moistened with mild, liquid detergent or denatured alcohol. Complete cleaning by rinsing well and drying with soft cloths.

INFORMATION ON DISPOSAL IN EUROPEAN UNION COUNTRIES The EU WEEE Directive was implemented differently in each country, accord- ingly, if you wish to dispose of this appliance we suggest contacting your local authorities or dealer to find out what the correct method of disposal is.

INFORMATION ON DISPOSAL IN NON-EUROPEAN UNION COUNTRIES The crossed-out trash or refuse bin symbol is only valid in the European Union: if you wish to dispose of this appliance in other countries, we suggest contacting your local authorities or dealer to find out what the correct method of disposal is.

Do not use too much moisture or water around the push button control panel and lighting devices in order to prevent humidity from reaching electronic parts.

The glass panels can only be cleaned with specific, non-corrosive or non-abra- sive detergents using a soft cloth. The Manufacturer declines all responsibility for failure to comply with these in- structions.

WARNING!

The Manufacturer reserves the right to make changes to the equipment at any time and without prior notice. Printing, translation and reproduction, even par- tial, of this manual are bound by the Manufacturer's authorisation. Technical information, graphic representations and specifications in this manual are for information purposes and cannot be divulged. This manual is written in Italian. The Manufacturer is not responsible for any tran- scription or translation errors.

CLEANING OF INTERNAL SURFACES

Do not clean electrical parts, or parts related to the motor inside the hood, with liquids or solvents. For the internal metal parts, see the previous paragraph.

Ask about the Falmec Alba

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Falmec Alba

Be the first to ask — other owners or our team will answer.

Original document

Falmec Alba manual PDF

88 pages·6.6 MB·Kitchen Range Hood·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…