Fig. 1

CT900 CT1090 Contemporary Falcon Cooker Hoods Contemporain Hottes Falcon Moderne Falcon - Dunstabzugshauben Eigentijds Falcon Afzuigkappen Modern Falcon Kåpor

ENGLISH 2

Installation, Operation

& Maintenance

Instructions

FRAN ÇAIS 3 Guide d ’Installation,

D ’Utilisation et Conseils d ’Entretien

DEUTSCHE 4 Montage-, Gebrauchs- & Wartungsanleitung

NEDERLANDS 5 Instructies voor montage, gebruik

en onderhoud

SVENSK 6 Installations-, danv ändnings - och underh ållsanvisningar

EN/FR/DE/NL/SV 7 HOOD DIMENSIONS and FIXING HOLE

DETAILS

DIMENSIONS DE LA HOTTE et D ÉTAILS

DE LA FIXATION DES TROUS

Haubenma ße Und Details zu

Montagel öchern

AFZUIGKAP AFMETINGEN En BEVES-

TIGINGSGATEN

K ÅPANS MÅTT Och FÄSTHÅLENS

PLACERING

Falcon CT1090 — DETAILS diagram (page 1)
Fig. 2

Clarence Street, Royal leamington Spa,

Warwickshire, CV31 2AD, England. Tel+44 (0) 1926 457400 Fax: +44 (0) 1926 450526

E-mail: [email protected]

www.falconappliances.co.uk

Page 2 of the Falcon CT1090 user manual — SECTION 7. SPECIFICATIONS
Page 2 · click to enlarge
Page 2

ENGLISH SECTION 1. INTRODUCTION Your range cooker is a semi-professional unit which gives you the power and flexibility to realise your full potential in the kitchen. Inevitably, during the cooking process, there will be heat, vapours and fumes produced. Your Falcon extractor has been designed to complement the range cooker both in looks and performance in order to create the ideal environment for creative cooking. SECTION 2. EXTRACTION PERFORMANCE The most important influence on the performance of the extractor is the design of the ducting which takes the exhaust air from the extractor to the outside wall louvre. The duct route should be a prime consideration during the initial stages of the kitchen design. Please note the following: The extractor is provided with a spigot suitable for connecting 150mm diameter duct.

Falcon Cooker Hoods: CT900/CT1090

4.5 Connecting the Ducting Connect ducting to extractor exhaust spigot. This may have to be done prior to fixing the extractor to the wall. You may find this easier with the chimney removed. The chimney is attached using M4 machine screws which can be accessed through the filter opening(s). When the extractor is in position, check that the duct has not been flattened or kinked along its route. Connect the ducting to the wall louvre spigot or alternative outside termination. Secure the louvre to the outside wall. Ensure that any air fins are directed downwards. Refit the grease filter(s). 4.6 Electrical Installation The extractor is a stationary appliance designed to be connected by fixed wiring to the electrical supply.

ELECTRICAL HAZARD DISCONNECT ELECTRICAL SUPPLY

BEFORE PROCEEDING FURTHER

The exhaust duct route length should be kept as short as possible with as few bends as possible.

A competent electrical technician must perform the electrical installation. The extractor must be fed from a 230Vac single phase electrical supply using a switched spur fitted with a 3A fuse. The spur should be located adjacent to the extractor/cooker so that the supply can be discon- nected from the extractor using the switch. The means of disconnecting from the supply must have a minimum contact separation of 3mm in all poles. Alternatively a means of disconnection in the fixed wiring according to the relevant wiring rules must be fitted. A supply cord for connecting the spur to the extractor is included. The mains supply is connected to the free end of this cord as follows:

The most efficient configuration is to duct straight through an outside wall so try to position the cooker against an outside wall when designing your kitchen layout. The hood can be vented either to the top exhaust or the rear exhaust position. Use the position which gives the shortest duct route length and least number of bends. (The blower will need to be rotated for ducting directly through the rear exhaust position.) A route with more than two 90 bends will significantly degrade the performance of the extraction system. If possible, avoid having a 90 bend at the extractor exhaust spigot; keep bend radii as large as possible to maintain a smooth airflow without vortices; avoid kinks in flexible ducting; pull flexible ducting taut over straight runs to ensure that the internal surface is as smooth as possible. SECTION 3. IMPORTANT INFORMATION The following minimum headroom is required to accommodate the cooker and hood:

INCOMING SUPPLY CORD CONNECTIONS CoreCore Colour LiveBrown NeutralBlue Protective EarthGreen/Yellow
Cooker-to-hood clearance (min):800 mm Hood height including chimney:550—950 mm Minimum ceiling height with standard chimney:2290mm

For a small charge customised replacement chimneys can be produced to suit your requirements. The minimum distance between the range hob burners and the bottom of the extractor is essential to prevent overheating of the extractor and its components. If you are fitting a splashback then the cooker-to-hood clearance is dictated by the splashback height. Please also note that a 90 bend in the flexible ducting will require 215mm minimum headroom to give a smooth radius with no kinking. Requirements of the relevant authorities concerning the discharge of exhaust air must be complied with.

SECTION 5. OPERATING INSTRUCTIONS

a. Switch power on at the fused spur.

b. The extractor has 6 push-buttons which illuminate when selected. Their functions are summarised in the table below.

c. The extractor controller will automatically switch off the appliance if there has been no operator action for 4 hours.

d. After 30 hours accumulated running GREASE FILTER SATURATION will be signalled by all 6 indicators flashing. Reset by pressing Push-button FAN OFF (delay).

Warning Proper care must be taken to ensure that the negative pressures caused by high performance extraction systems do not adversely affect the safe operation of certain types of fuel-burning appliances (gas, oil or solid fuel), including those installed in the kitchen and possibly also those installed in other parts of the house. Where such fuel-burning appliances are installed, adequate ventilation MUST be provided in the room of installation, located and sized such that the negative pressure in the room created by the extractor does not exceed 4Pa. In case of doubt, do not operate the extractor and fuel-burning appliance(s) simultaneously and consult an appropriate (for the fuel type) expert for advice.

PushbuttonFunction LIGHTS ON/OFF 0 1FAN ON SPEED 1 (min); FAN OFF (immediate stop). 2FAN ON SPEED 2 3FAN ON SPEED 3 4FAN ON SPEED 4 (max) FAN OFF AFTER 10 MINUTE DELAY to clear residual fumes; indicator flashes during time-out.

The exhaust air must not be discharged into a flue which is used for exhausting fumes from appli- ances supplied with energy other than electricity, e.g. oil or gas-fired central heating boilers, gas- fired water heaters, etc.

Adequate ventilation of the room must be provided when the cooker, extractor and appliances supplied with energy other than electricity (e.g. gas-fired or oil-fired heaters, etc.) are used simulta- neously. The room must be provided with vents to allow a constant flow of fresh air.

SECTION 6. MAINTENANCE

Regular maintenance is essential to ensure good performance and long-life.

To clean the stainless steel surfaces of the extractor use a proprietary cleaning agent. Do not use abrasive cleaning materials or products.

Attention: This appliance requires an earth connection. Ensure that the supply voltage corresponds to that marked on the rating label inside the extractor. The extractor must be isolated from the electrical supply before carrying out any cleaning or mainte- nance operations. Pay particular attention to fire risk when frying. To minimise the risk of fire, all instructions relating to cleaning the grease filters and removing grease deposits must be adhered to. Do not flambé under the extractor.

Clean the grease filters in a dishwasher or by hand-washing in hot water and detergent. Wash the filters at least every 2 months - sooner if the extractor is used extensively.

To remove the grease filters pull the chrome effect filter release lever away from the hood base. This releases the retaining clips allowing the filter to be carefully lifted away from the hood. Care should be taken not to scratch the hood.

To maintain the immaculate appearance of the extractor, and to minimise fire risk, ensure that grease deposits on the extractor surfaces are kept to a minimum by regular cleaning.

To access the halogen lamps for replacement lever off the chrome ring immediately surrounding the matt glass with a screwdriver. Only replace with bulbs of the same type and rating.

SECTION 4. INSTALLATION 4.1 Removing the Grease Filter(s) Place extractor on its backplate on a horizontal surface. To remove the grease filters pull/lift the filter release lever away from the hood base. This releases the retaining clips allowing the filter to be carefully lifted away from the hood. Take care not to scratch the hood. The internal fixing holes, blower assembly and spigot blanking plate can now be accessed through the openings in the baseplate. (See Page 7). 4.2 Blower Exhaust Position The hood can be vented either to the top exhaust or the rear exhaust position. Each exhaust position has 4 studs onto which can be bolted either the blower assembly or a blanking plate. Bolt blower assembly to chosen exhaust position and the blanking plate to the unused position. When changing the exhaust position, care should be taken not to excessively pull or twist the cable attached to the blower. 4.3 Duct Installation Make a hole in the wall or ceiling to take the 150mm diameter ducting from the extractor exhaust spigot to the outside. The exhaust duct route length should be kept as short as possible with as few bends as possible - see Section 2. Knock a hole in the outside wall to match the internal measurements of the louvre. 4.4 Fixing the Hood to the Wall If you are fitting a Splashback it must be fitted before the hood. Instructions for mounting the hood are given on page 7 Note: The decorative chimney can be removed to ease handling of the hood. The supporting wall must be of good quality, have an even surface and be sturdy enough to support the extractor. Fixings must be used which are suitable for the type of wall construction.

SECTION 7. SPECIFICATIONS

Blower airflow, nominal:1000 m3/hr Noise level (typical max installed):52dBA Supply voltage:230V~ 50Hz Halogen lamp voltage:12V Blower power input:1 @ 250W Halogen lamp power:2 x 20W Total power:290W Fuse size for electrical supply:3A Blower spigot diameter:150mm
CT90026Kg CT109229Kg
Page 7 of the Falcon CT1090 user manual — EN/FR/DE/NL/SV
Page 7 · click to enlarge
Page 7

EN/FR/DE/NL/SV

Falcon Cooker Hoods: CT900/CT1092

HOOD DIMENSIONS And FIXING HOLE DETAILS DIMENSIONS DE LA HOTTE et DÉTAILS DE LA FIXATION DES TROUS Haubenmaße Und Details zu Montagelöchern AFZUIGKAP AFMETINGEN En BEVESTIGINGSGATEN KÅPANS MÅTT Och FÄSTHÅLENS PLACERING

Falcon CT1090 — EN/FR/DE/NL/SV diagram (page 7)
Fig. 3

ENGLISH: Method 1. Mark a horizontal line (A) in the position of the hoods bottom edge - if you have already fitted a splashback then the top edge of this will serve. 2. Mark a vertical centre line of the range cooker and the hood (B). 3. Remove the grease filters to gain access the internal fixing holes. 4. Mark the positions of the fixing hole centres, as shown above tip: Offer the hood up to the wall in the desired position and mark the wall through the fixing holes in the hood rear. This is a 2 person job. 5. Mark and prepare a hole suitable to accommodate 150mm diameter ducting (160mm min). If using the rear exhaust spigot position then accuracy is critical. 6. Secure hood and chimney bracket, using fixings suitable for the wall construction, in the previ- ously marked positions. FRANÇAIS: Méthode 1. Marquez une ligne horizontale (A) dans la position désirée de la base de la hotte. 2. Marquez une ligne centrale verticale du fourneau et la hotte (B). 3. Marquez les centres de trous de fixation comme indiqués ci-dessus

NEDERLANDS: Methode 1. Trek een horizontale lijn ( A ) langs de onderzijde van de afzuigkap. Bij gebruik van een achterwand, kunt u de bovezijde ervan horizontaal gebruiken. 2. Trek een vertikale lijn vanuit het midden van het fornuis en de afzuigkap ( B ). 3. Markeer de posities van de bevestigingsgaten zoals op de tekening boven te zien is. Tip: Houd de afzuigkap in de gewenste positie tegen de muur en markeer de gaten in de achterkant van de afzuigkap. Doe dit met 2 personen. 4. Maak een gat voor de 150mm afvoerslang (160mm min). 5. Bevestig de afzuigkap aan de wand met schroeven die ervoor geschikt zijn. De gaten zijn te zien als de filters zijn verwijderd, zie hoofdstuk 4.4. SVENSK: Metod 1. Dra en vågrät linje (linje A) där kåpans undre kant ska placeras. Om ett stänkskydd redan har monterats duger dess överkant. 2. Dra en lodrät linje vid spisens och kåpans centrum (linje B). 3. Markera placeringen för centrum av fästhålen enligt ovan. tip: Håll upp kåpan på väggen i önskat läge och gör märken på väggen genom fästhålen i kåpans baksida. Två personer erfordras för detta. 4. Markera och gör ett hål som passar en 150 mm kanal (160mm min), enligt anvisningar i installationshandboken. 5. Fäst kåpan och skorsten fäste i de markerade lägena med fästelement som passar väggkonstruktionen. Fästhålen syns när filtren tas bort enligt anvisningarna i installationshandboken.

Tip: Présentez la hotte contre le mur dans la situation désirée. Deux personnes sont nécessai- res pour cette opération. Marquez le mur par les trous de fixation dans la partie arrière de la hotte. 4. Marquez et faites un trou pour accepter un conduit d’un diamètre de 150mm comme détaillé dans le guide d’installation (160mm min). 5. Fixez la hotte et fixation cheminée en vous servant des fixations qui conviennent à la construction du mur dans les postions déjà marquées. Les trous de fixation sont révélés quand les filtres sont enlevées comme détaillé dans le guide d’installation. DEUTSCHE: Methode 1. Eine waagerechte Linie (Linie A) an der unteren Kante der Haube markieren – wenn bereits ein Spritzschutz angebracht wurde, kann dessen obere Kante verwendet werden. 2. Eine senkrechte Mittellinie von Herd und Haube markieren (Linie B). 3. Die Positionen von Montagelöchern wie oben beschrieben markieren. Tipp: Die Haube an die gewünschte Position halten und die Wand durch die Montagelöcher in der Rückwand der Haube markieren. Hierzu sind 2 Personen notwendig. 4. Ein Loch (160mm min), das für den Schacht mit 150 mm Durchmesser geeignet ist, gemäß der Montageanleitung markieren und herausbrechen. 5. Zum Befestigen der Haube und Kamin Befestigungshalteren für den jeweiligen Wandtyp geeignete Befestigungselemente an den bereits erstellten Markierungen verwenden.

Ask about the Falcon CT1090

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Falcon CT1090

Be the first to ask — other owners or our team will answer.

Original document

Falcon CT1090 manual PDF

7 pages·266 KB·Kitchen Range Hood·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…