Instruction/ maintenance manual of the product ME758C-RJ11 Black Box
Go to page of 40
CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500 ) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mailing address: Black Box Corporation , 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.
1 FCC ST A TEMENTS FEDERAL COMMUNICA TIONS COMMISSION AND INDUSTR Y CANADA RADIO FREQUENCY INTERFERENCE ST A TEMENTS This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication.
2 MUL TI-FUNCTION LD CARD NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY ST A TEMENT INSTRUCCIONES DE SEGURIDAD 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
3 NOM ST A TEMENTS 12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada. 13. Los cables de la fuente de poder deben ser guiados de tal mane.
4 MUL TI-FUNCTION LD CARD Contents Chapter Page 1. Specifications ............................................................................................. 5 2. Introduction .........................................................................
5 CHAPTER 1: Specifications 1. Specifications Hardware Required — Cards can be installed only in MicroRacks (see Section 4.1 ) Cable Required — For modem-to-modem line: Two- or four-wire unconditioned twisted-pair, 19 to 26 AWG (see the Appendix ), pinned as shown in Section 4.
6 MUL TI-FUNCTION LD CARD Data Rates — 57.6, 38.4, 28.8, 19.2, 14.4, 9.6, 7.2, 4.8, 3.6, 2.4, or 1.2 kbps (user-selectable) Maximum Distance — See the maximum distance chart in the Appendix Isolat.
7 CHAPTER 1: Specifications (1) 50-position card-edge male (to MicroRack); On interface module: All models: (1) 50-position card-edge male (to MicroRack); ME758C-RJ11: (1) 6-pin RJ-11 female for modem.
8 MUL TI-FUNCTION LD CARD 2. Introduction 2.1 Overview The Multi-Function LD Card is a short-range modem on a dual rack card (it has a main [front] module and an interface [rear] module).
9 CHAPTER 2: Introduction • Internal, external, or received loopback clocking • Hardware or software flow control • Automatic equalization and gain control • Anti-streaming timer • Built-in transformer isolation and high-speed surge protection • V.
10 MUL TI-FUNCTION LD CARD This chapter describes the locations and posssible settings of the Multi- Function LD Card’s configuration controls, and provides detailed instructions for setting them. Section 3.1 tells you about the three 8-position DIP switches on the Card’s main (front) module.
11 CHAPTER 3: Configuration 3.1.2 C ONFIGURATION S WITCH “S1” Use the individual positions on DIP switch S1 to set data rate, clock source, sync vs. async protocol, and carrier-control method. The factory-default settings are summarized in Table 3-1 below.
12 MUL TI-FUNCTION LD CARD S1 Positions 1 through 4: Data-Rate Setting Set positions 1 through 4 of switch S1 to determine the data rate (valid for both synchronous and asynchronous protocols) of the Multi-Function LD Card. S1-1 S1-2 S1-3 S1-4 Data Rate On On On On 1.
13 CHAPTER 3: Configuration S1 Position 8: Carrier-Control Method Set position 8 of switch S1 to determine whether the carrier is “constantly on” or “controlled by RTS.” In the “controlled by RTS” setting, the Switch can support switched-carrier, multipoint, or hardware flow-control applications.
14 MUL TI-FUNCTION LD CARD S2 Position 3: V.52 and V.54 Diagnostic Testing To reset the V.54 circuit, turn switch S2 position 3 ON, then back OFF. S2-3 Test Mode Off Normal Operation (default) On Test.
15 CHAPTER 3: Configuration 3.1.4 C ONFIGURATION S WITCH “S3” Use the individual positions on DIP switch S3 to set antistream control, receive (input) impedance, and point-to-point/multipoint, as well as to enable or disable local and remote loopbacks.
16 MUL TI-FUNCTION LD CARD T able 3-4. Recommended Impedance Settings S3-4: Mode Selection Set position 4 of switch S3 to determine whether the Multi-Function LD Card operates in point-to-point or multipoint mode.
17 CHAPTER 3: Configuration S3-7 and S3-8: Antistream Control Set positions 7 and 8 of switch S3 to determine the timeout period for the Multi-Function LD Card’s antistream-control timer, or to disable the timer entirely. S3-7 S3-8 Setting Off Off Disabled (default) Off On 12.
18 MUL TI-FUNCTION LD CARD Figure 3-3, below, shows the rear panels of each of these interface modules. Before you install the Card, you should examine the interface module you have selected and make sure that it is configured for your application. Each interface module has three jumpers on its circuit board, as described in the following sections.
19 CHAPTER 3: Configuration 3.2.3 W HERE THE J UMPERS A RE Figure 3-5, below, shows the locations of the jumpers on the interface modules (the locations are the same for both the -RJ11 and -RJ45 models). These jumpers determine various grounding and signal characteristics for the serial and modem-to-modem lines.
20 MUL TI-FUNCTION LD CARD Table 3-5, below, provides a summary of the functions of these jumpers. The functions are described in more detail afterward. T able 3-5. Summar y of Interface-Module Jumper Functions Line Interface: Line Shield Connection to Frame Ground (JB2) This jumper applies to the line interface.
21 CHAPTER 3: Configuration Serial Interface: DTE Shield (Pin 1) Connection to Frame Ground (JB3) This jumper applies to the serial interface. In position 1 and 2, this jumper links the Protective Ground (PGND) or “DTE Shield” lead (DB25 Pin 1 or 10- pin RJ Pins 1 and 10) of the RS-232 line to the interface module’s frame ground (FGND).
22 MUL TI-FUNCTION LD CARD 4. Installation This chapter describes the functions of the MicroRacks, tells how to install the front and rear modules of the Multi-Function LD Cards in them, and provides diagrams for wiring the interface connections correctly.
23 CHAPTER 4: Installation 4.2 The MicroRacks’ Power Supply The power supply included with the MicroRacks uses the same mid-plane architecture as the line-driver cards. Slide the front module of the power supply into the MicroRack from the front, and slide the rear module in from the rear.
24 MUL TI-FUNCTION LD CARD 4.2.3 S WITCHING THE P OWER S UPPLY B ETWEEN 120 AND 240 V OLTS Although the MicroRack is shipped from the factory with a customer-specified power-supply configuration, you may change the configuration yourself. Follow these steps to switch the configuration of the power supply between 120 VAC and 240 VAC: 1.
25 CHAPTER 4: Installation 4.4 The RS-232 Serial Cables and Connectors The Multi-Function LD Card’s RS-232 port is always the lower port on its interface module. On ME758C models it is a standard DB25 connector (pinout shown in Table 4-1 below, top).
26 MUL TI-FUNCTION LD CARD The Multi-Function LD Card is wired as a DCE (Data Communications Equipment) device. Therefore, it would normally be connected to a DTE (Data Terminal Equipment) RS-232 device.
27 CHAPTER 4: Installation T able 4-3. Line-Cable Pinouts RJ-11 (Four-Wire) SIGNAL PIN# COLOR* COLOR* PIN# SIGNAL GND** 1 Blue..................................................White 6 GND** RCV–† 2 Yellow ..........................................
28 MUL TI-FUNCTION LD CARD 4.6 Multipoint Applications The Multi-Function LD Card supports multipoint applications using equipment arranged in a star topology. Maximum distance between the units will vary based on the number of drops, data rate, wire gauge, etc.
29 CHAPTER 5: Operation and Diagnostics 5. Operation and Diagnostics Once you have configured each Multi-Function LD Card and connected the cables, you are ready to operate the units. This chapter describes the Card’s LEDs, the power-up procedure, and diagnostic testing.
30 MUL TI-FUNCTION LD CARD 5.1.2 T HE RTS AND CD I NDICATORS The RTS and CD indicators (again, one red and one green LED for each signal) function much like the TD and RD LEDs: The red LEDs light for a “low” signal, while the green LEDs light for a “high” signal.
31 CHAPTER 5: Operation and Diagnostics 5.2 Diagnostic T esting Using the Error LED 5.2.1 T ESTING C ABLE Q UALITY NOTE The Error LED’s circuitry is designed to detect line quality across 4-wire twisted-pair cable only, and might not function properly with 2-wire cable.
32 MUL TI-FUNCTION LD CARD NOTE We cannot guarantee that the Card will accurately detect small pieces of flat satin cable in the line if they are farther than 1500 ft. (457.2 m) from the local modem. C. If one wire among the four twisted-pair wires is broken, the Error LED and the green CD LED will both light on at least one of the modems.
33 CHAPTER 5: Operation and Diagnostics When the local and remote Multi-Function LD Cards are both powered up and are passing data normally , the LEDs on the Cards will look like this: • Power: Steadily lit • TD and RD: Flashing red and green • RTS and CD: Green steadily lit, red dark • Test and Error: Dark 5.
34 MUL TI-FUNCTION LD CARD 4. If the BERT test indicates no errors are present, move the “511/E—511” toggle switch to the left-hand position to activate the “511/E” test with periodic errors. If this test is working properly, the Error LED will blink regularly .
35 CHAPTER 5: Operation and Diagnostics 4. If the BERT test indicates no errors are present, move the “511/E—511” toggle switch to the left-hand position to activate the “511/E” test with periodic errors. If this test is working properly, the Error LED will blink regularly .
36 MUL TI-FUNCTION LD CARD 6. T roubleshooting 6.1 Calling Y our Supplier If you determine that your Multi-Function LD Card is malfunctioning, do not attempt to alter or repair it. Contact your supplier. The problem might be solvable over the phone. Before you do, make a record of the history of the problem.
37 APPENDIX: Cable Recommendations Appendix: Cable Recommendations The Multi-Function LD Card has been performance-tested using twisted-pair cable with these characteristics: Wire Gauge Capacitance Resistance 19 AWG 83 nf/mi. or 15.72 pf/ft.* 16.3 Ω /1000 ft.
38 MUL TI-FUNCTION LD CARD To gain optimum performance from the Multi-Function LD Card, please keep these guidelines in mind: • Always use twisted-pair cable—this is not an option. • Use twisted-pair cable with a capacitance of 20 pf/ft. (65.6 pf/m) or less.
1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746 © Copyright 1995. Black Box Corporation. All rights reserved..
An important point after buying a device Black Box ME758C-RJ11 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Black Box ME758C-RJ11 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Black Box ME758C-RJ11 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Black Box ME758C-RJ11 you will learn all the available features of the product, as well as information on its operation. The information that you get Black Box ME758C-RJ11 will certainly help you make a decision on the purchase.
If you already are a holder of Black Box ME758C-RJ11, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Black Box ME758C-RJ11.
However, one of the most important roles played by the user manual is to help in solving problems with Black Box ME758C-RJ11. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Black Box ME758C-RJ11 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center