Contentsp.31 Read directly pleasep.51.1 Key cluesp.51.2 Intended usep.51.3 Legal requirements and rulesp.51.4 Energy-saving use of the heat pumpp.62 Purpose of use of the heat pumpp.62.1 Scopep.62.2 Method of workingp.63 Basic devicep.63.1 Generalp.63.2 Hydraulic module for glycol water/waterp.73.3 Heat pump modulep.74 Accessoriesp.74.1 Glycol water distributorp.74.2 Glycol waterpressostatp.84.3 Remote controlp.84.4 Building management systemp.84.5 Smart RTCp.85 Transportp.85.1 Generalp.85.2 Remove the cover platesp.95.3 Remove the heat pump modulep.96 Placementp.116.1 General instructionsp.116.2 Noise emissionsp.117 Assemblyp.117.1 Generalp.117.2 Connection heating sidep.117.3 Connection to the heat sourcep.127.4 Hot water connectionp.127.5 Temperature sensorsp.137.6 Electrical connectionp.138 Entry into servicep.148.1 Generalp.148.2 Preparationp.148.3 Operation of the commissioning processp.149 Maintenance / cleaningp.159.1 Maintenancep.159.2 Heating side cleaningp.159.3 Cleaning on the side of the heat sourcep.1510 Malfunctions / malfunction diagnosisp.1511 Decommissioning/disposal of wastep.1512 Device Informationp.16Annexp.191 Size sketchp.203.6 Legendp.214 Electric diagram heat pump modulep.234.1 Sturdynessp.234.2 Powerp.244.3 Connection schemep.254.4 Legendp.265 Hydraulic connection diagramp.275.1 Connection scheme for a heating circuit with underfloor heating and room temperature control via Smart RTC, hot water preparationp.275.2 Connection scheme for a heating circuit with series-switched buffer tank and hot water preparationp.285.3 Legendp.296 Declaration of conformityp.30
Page 1 of the Dimplex SIW 11TU user manual — Order No: 452236.66.01 FD 9206
Page 1 · click to enlarge
Page 1

SIW 6 TU SIW 8TU SIW 11TU

Dimplex SIW 11TU — SIW 6 TU SIW 8TU SIW 11TU diagram (page 1)
Fig. 1

Mounting instructions

Diagram . .
Diagram . .

Very efficient compact soil/ heat pump with integrated hot water boiler

Order No: 452236.66.01 FD 9206

Page 2 of the Dimplex SIW 11TU user manual
Page 2 · click to enlarge
Page 2
Page 2 of the Dimplex SIW 11TU user manual
Page 3 of the Dimplex SIW 11TU user manual — Table of Contents
Page 3 · Contents
Contents

Contents

Contentsp.31 Read directly pleasep.51.1 Key cluesp.51.2 Intended usep.51.3 Legal requirements and rulesp.51.4 Energy-saving use of the heat pumpp.62 Purpose of use of the heat pumpp.62.1 Scopep.62.2 Method of workingp.63 Basic devicep.63.1 Generalp.63.2 Hydraulic module for glycol water/waterp.73.3 Heat pump modulep.74 Accessoriesp.74.1 Glycol water distributorp.74.2 Glycol waterpressostatp.84.3 Remote controlp.84.4 Building management systemp.84.5 Smart RTCp.85 Transportp.85.1 Generalp.85.2 Remove the cover platesp.95.3 Remove the heat pump modulep.96 Placementp.116.1 General instructionsp.116.2 Noise emissionsp.117 Assemblyp.117.1 Generalp.117.2 Connection heating sidep.117.3 Connection to the heat sourcep.127.4 Hot water connectionp.127.5 Temperature sensorsp.137.6 Electrical connectionp.138 Entry into servicep.148.1 Generalp.148.2 Preparationp.148.3 Operation of the commissioning processp.149 Maintenance / cleaningp.159.1 Maintenancep.159.2 Heating side cleaningp.159.3 Cleaning on the side of the heat sourcep.1510 Malfunctions / malfunction diagnosisp.1511 Decommissioning/disposal of wastep.1512 Device Informationp.16Annexp.191 Size sketchp.203.6 Legendp.214 Electric diagram heat pump modulep.234.1 Sturdynessp.234.2 Powerp.244.3 Connection schemep.254.4 Legendp.265 Hydraulic connection diagramp.275.1 Connection scheme for a heating circuit with underfloor heating and room temperature control via Smart RTC, hot water preparationp.275.2 Connection scheme for a heating circuit with series-switched buffer tank and hot water preparationp.285.3 Legendp.296 Declaration of conformityp.30
Page 5 of the Dimplex SIW 11TU user manual — www.dimplex.de 452236.66.01 · FD 9206 EN-3
Page 5 · click to enlarge
Page 5

1 Read directly please

1.2 Intended use

This apparatus has been released for the intended purpose only by the manufacturer. Any other or far-reaching use shall be considered as improper. For this purpose, compliance with the relevant product documentation shall be included. It is not allowed to change the device or rebuild it.

1.1 Key clues

1.3 Legal requirements and rules

This heat pump is intended for domestic use under Article 1 (2) (k) of the EC Directive. The pump is therefore also intended for use by laymen to heat shops, offices and other similar working environments as well as heating agricultural holdings, hotels, boarding houses or the like or for heating other residential facilities.

The heat pump complies with all relevant DIN/VDE requirements and EC guidelines. You can find these in the CE declaration in the Annex.

The electrical connection of the heat pump shall be performed according to valid VDE, EN and IEC standards and in accordance with the General Regulation for Electrical Installations (A.R.E.I.). Furthermore, the connection conditions of energy companies must be respected.

The heat pump shall be integrated into the heating system in accordance with the relevant requirements.

Persons, especially children, who are unable to use the device safely due to their physical, sensory or mental skills or because of lack of knowledge or experience, shall not be allowed to use it without supervision or instructions from a responsible person.

Always keep an eye on children to make sure they don't play with the device.

www.dimplex.de 452236.66.01 · FD 9206 EN-3

Page 6 of the Dimplex SIW 11TU user manual — EN-4 452236.66.01 · FD 9206 www.dimplex.de
Page 6 · click to enlarge
Page 6

3 Basic device

1.4 Energy-saving use of the heat pump

3.1 General

By using this heat pump you contribute to the stool of our environment. For efficient operation, careful dimensioning of the heating system and its heat source is very important. Particular attention should be paid to the lowest possible water flow temperature. Therefore, all connected energy consumers should be suitable for low running temperatures. A 1 K higher heating temperature increases energy consumption by approx. 2.5 %. Low temperature heating with pre-flow temperatures between 30 °C and 50 °C is suitable for energy saving.

The base unit consists of a compact heat pump for installation inside with integrated hot water boiler.

All components necessary for the operation of the heat pump are installed on the switch box with heat pump manager. A sensor for the outside temperature with mounting material as well as a filter are included in the heat pump. The power supply for the power and steering voltage shall be installed on site.

The heat source system with the glycol water distributor shall be installed on site.

During the use of the heat pump, the hot water temperature shall not exceed 45 °C. This allows you to save significantly on energy consumption.

Diagram . .
Diagram . .

2 Purpose of use of the heat pump

2.1 Scope

The highly efficient compact soil/water heat pump with integrated hot water boiler is only intended for heating heating water and water for industrial purposes. The pump can be used in existing or newly installed heating systems. The heat carrier in the thermal source installation is glycol water. The heat source may be used as earth dons, collectors or similar installations.

2.2 Method of working

The soil stores the heat of the sun, wind and rain. This geothermal heat is in the earth collector, the Earth dones and so on. absorbed by the glycol water at a low temperature. A circulating pump then transports the "heated" glycol water to the vaporizer of the heat pump. This heat is transferred to the coolant in the cooling cycle. The glycol water cools off again, so that it can absorb heat energy back into the glycol water circuit.

The coolant is sucked in by the electrically driven compressor, compressed and pumped to a higher temperature level. The electrical energy supplied in this process is not lost, but is largely transferred to the coolant.

1. Hydraulic module for glycol water/water
2. Switch panel with heat pump manager
3. Heat pump module

Then the coolant enters the condenser and here again transfers its heat energy to the heating water. Depending on the working point, heating water can be heated to 62 °C.

EN-4 452236.66.01 · FD 9206 www.dimplex.de

Page 7 of the Dimplex SIW 11TU user manual — www.dimplex.de 452236.66.01 · FD 9206 EN-5
Page 7 · click to enlarge
Page 7

3.2 Hydraulic module for glycol water/water

3.3 Heat pump module

The cooling cycle is "remetically closed" and contains the fluorideed coolant R410A specified in the Kyoto Protocol with a GWP value of 1975. It is CFC free, does not break down ozone and is not flammable.

The hydraulic module for glycol water/water contains the components of the heating and glycol water circuit necessary to connect the heat pump.

The heat pump module switch box shall contain all components necessary for the operation of the cooling cycle.

Diagram . .
Diagram . .
Diagram . .
Diagram . .
11. Compressor
12. Condensor
13. Vadiator
14. Economist
15. Filter dryer
16. Expansion valve
17. Switchbox heat pump module

4 Accessories

4.1 Glycol water distributor

The glycol water distributor unites the collector or probe loops into one main line, which is connected to the heat pump. The integrated ball valves can be used to seal separate glycol water circuits for venting or emptying them.

1. Ventilation
2. Manometer of heating
3. Manometer glycol water
4. Hot water boiler
5. Switch valve heating / hot water
6. Overflow valve
7. Radiator
Fig. 4.1Mounting glycol water distributor or collector
8. Heating circulation pump

The collector or probe tubes shall be connected from below with an arc to the distributor in order to allow for linear

9. Glycol water circulation pump
10. Water outlet storage vessel

www.dimplex.de 452236.66.01 · FD 9206 EN-5

Page 8 of the Dimplex SIW 11TU user manual — EN-6 452236.66.01 · FD 9206 www.dimplex.de
Page 8 · click to enlarge
Page 8

to compensate for expansion in summer or winter (stress tearing).

4.5 Smart RTC

The Smart RTC is a space temperature control with display, which displays the actual room temperature and allows you to set your desired room temperature. The Smart RTC is available as a build-in variant (RT Econ A) or as an installation variant (rt Econ U). Temperature sensors for both variants are already integrated to record room temperature.

4.2 Glycol waterpressostat

If a glycol water pressure medium is prescribed, it can be incorporated into the main heat source (accessory pack of glycol water) as follows.

Diagram . .
Diagram . .

The additional assembly instructions of the Smart RTC shall be observed for installation and operation.

Diagram . .
Diagram . .

4.3 Remote control

5 Transport

For more comfort, a remote control unit is available as special accessories. Control and menu navigation are identical to that of the heat pump manager. Connection with a 6-vein telephone cord (special accessories) with western contacts.

5.1 General

A lift truck is suitable for transport over a solid surface. If the heat pump is transported on an uneven surface or over stairs, it can be carried with straps. These can be placed directly under the pallet.

Diagram . .
Diagram . .

4.4 Building management system

The heat pump manager can be connected to the network of a building management system with appropriate expansion. For the precise connection and configuration of the interface, the additional mounting instructions for the extension shall be observed.

The following connections are possible for the heat pump manager:

EIB, KNX

EN-6 452236.66.01 · FD 9206 www.dimplex.de

Modbus · Ethernet

Page 9 of the Dimplex SIW 11TU user manual — www.dimplex.de 452236.66.01 · FD 9206 EN-7
Page 9 · click to enlarge
Page 9

5.2 Remove the cover plates

To get to the inside of the device, it is possible to remove all front plates.

Diagram . .
Diagram . .
Diagram . .
Diagram . .
Fig. 5.1open bottom front plate
Diagram . .
Diagram . .
Fig. 5.3 5.3Open side panels

5.3 Remove the heat pump module

If the heat pump module is removed, it can be transported in a simple manner while transporting the heat pumps module separately.

Fig. 5.2Open top front plate

www.dimplex.de 452236.66.01 · FD 9206 EN-7

Page 10 of the Dimplex SIW 11TU user manual — EN-8 452236.66.01 · FD 9206 www.dimplex.de
Page 10 · click to enlarge
Page 10
Diagram . .
Diagram . .

After transport, the transmission device on the heat pump module shall be removed from both sides.

Diagram . .
Diagram . .
Diagram . .
Diagram . .

EN-8 452236.66.01 · FD 9206 www.dimplex.de

Page 11 of the Dimplex SIW 11TU user manual — www.dimplex.de 452236.66.01 · FD 9206 EN-9
Page 11 · click to enlarge
Page 11

6 Placement

7 Assembly

6.1 General instructions

7.1 General

The compact bottom/water heat pump shall be placed in a frost-free and dry space on an even, smooth and horizontal surface. The frame must be close to the ground in order to ensure adequate sound insulation. The substrate shall be capable of carrying the weight of the heat pump and the amount of hot water. If feet are used, the heat pump shall be levelled. In this case, the declared sound level may be up to 3 dB(A) and additional noise insulating measures become necessary.

The heat pump can be connected to the following connections:

7.2 Connection heating side

The heat pump shall be designed so that repair and maintenance work on the appliance can be carried out without any problems. This is guaranteed if a distance of approx. 1 m is held. If the heat pump is only accessible from the front (e.g. If installed in niches, etc.), the heat pump module can be removed by the service department (see Chapter 5).

Before connecting the heat pump to the hot water side, the heating system should be flushed down in order to allow possible dirt, residual insulation etc. to be removed. If the condenser is blocked by residual and contamination, this may lead to a failure of the heat pump.

Diagram . .
Diagram . .

After installation of the heating side, the heating system must be filled, ventilated and suppressed.

When filling the installation, care shall be taken:

untreated filling and supplemental water must have drinking water quality (colourless, clear, without deposits)

the filling and supplemental water must have been pre-filtered (porespan max. 5 μm)

Limestone formation in hot water heating systems cannot be completely prevented, but is negligible for installations with pre-run temperatures below 60 °C.

The mounting space shall not be subject to seasonal frost or temperatures higher than 35 oC.

For heat pumps for medium and high temperature, temperatures above 60 °C can also be reached.

6.2 Noise emissions

Thanks to the effective sound insulation, the heat pump works very quietly. Audio transmission to the foundation or base the heating system is highly prevented by internal decoupling measures.

Therefore, the following guide values for filling and supplementing water according to VDI 2035 sheet 1 shall be used:

Total hardness in °dH

in moles/m3 or

tot 200 2,0 11,2 200 tot 600 1,5 8,4 > 600 < 0,02 < 0,11

Min. heat water flow rate

The minimum heat pump heating water flow rate shall be guaranteed in each operating condition of the heating installation.

This can be done by a constantly open heating circuit, e.g. be reached in a reference space controlled by a room temperature regulator (available as special accessories).

(see connection schedule Fig. 5.1 on p.o.b. XVIII)

www.dimplex.de 452236.66.01 · FD 9206 EN-9

Show 10 more labels / short text on this page
Pre-flow/return glycol water (heat source system) · Pre-treatment/return heating · Hot water outlet · Cold water supply · Voltage · Temperature sensor · Total earth alkalis · Total heating / power in [kW] · mmol/l
Page 12 of the Dimplex SIW 11TU user manual — EN-10 452236.66.01 · FD 9206 www.dimplex.de
Page 12 · click to enlarge
Page 12

7.4 Hot water connection

7.4.1 General

When the heat pump manager and heating circulation pumps are ready to operate, the frost protection of the heat exchanger manager works. The installation shall be emptied if the heat pump is shut down or if power failure occurs. In the case of heat pump systems where power failure cannot be recognised (holiday home), an appropriate frost protection shall be provided for the heating circuit.

Installation and commissioning shall be carried out by a certified specialist company. The operation and density of the entire system must be checked, including parts installed in the factory. The stainless steel storage vessel is suitable for normal drinking water according to EN 1,4162. Maximum chloride content in drinking water must be maintained.

The volume of the heating water shall be checked by the designer of the installation. An expansion vessel must be installed on site in the return line (according to DIN 4751 part 1). Tables in manufacturers' catalogues simplify the dimensioning of water to the installation.

Hot water temperature in °CChloride content in mg/l 20< 100 70< 50

The connection shall be made according to DIN 1988 and DIN 4753 Part 1. The country-specific rules should be respected.

7.3 Connection to the heat source

The following materials can be found in the existing hot water circuit:

The connection shall be performed as follows:

Connect the glycol water line to the front run and return of the heat pump.

The hydraulic connection diagram must be observed.

Depending on the material used in the hot water environment (on site installation) corrosion can be caused by intolerable materials. This should be observed in particular when using raw materials containing zinc and aluminium. If there is a risk of contamination in the water when used, it may be necessary to provide for filter.

The supplied filter shall be mounted on site in the glycol water input of the heat pump.

The glycol water shall be prepared before filling the installation. The concentration of glycol water shall be at least 25%. This ensures frost clearance up to -14 °C.

Only monoethylene glycol or propylene glycol-based antifreeze agents may be used.

The working overprints shown on the type-plate shall not be exceeded. A pressure release device may need to be mounted.

The heat source system shall be ventilated and checked for density.

7.4.2 Entry into service

Before putting in service, check that the water supply is open and the storage vessel is full.

The hot water boiler shall be provided with a certified spring-loaded membrane safety valve on site. No locking device shall be fitted between the storage vessel and the safety valve. The failure-free operation of the valve shall be checked regularly. Annual maintenance of the installation by a specialist company is advisable.

EN-10 452236.66.01 · FD 9206 www.dimplex.de

Show 4 more labels / short text on this page
Copper · Stainless steel · Brass · Plastic
Page 13 of the Dimplex SIW 11TU user manual — www.dimplex.de 452236.66.01 · FD 9206 EN-11
Page 13 · click to enlarge
Page 13

7.5 Temperature sensors

7.5.2 Assembly of the external temperature sensor

The following temperature sensors are already built in or. shall be fitted in addition.

The temperature sensor must be installed in such a way that all weather conditions are recorded and the measurement value is not falsified.

Return temperature heating circuit (R2) built-in

on the outer wall of a heated living area, and

Primary circuit return temperature (R24) built-in

attach to the north/north-west side if possible

Pre-flow temperature heating circuit (R9) built in

Primary circuit pre-flow temperature (R6) built in

not in a "shut-down place' (e.g. in a wall niche or under

not near windows, doors, vents,

7.5.1 Footer characteristics

Fixing external or heat pumps

do not expose to direct sunlight in any season

Diagram . .
Diagram . .

Temperature in °C -20 -15 -10 -5 0 5 10

Feeding mode: Length max. 40 m; vein diameter min. 0.75 mm2; cable outside diameter 4-8 mm.

NTC-2 in k 14,6 11,4 8,9 7,1 5,6 4,5 3,7

NTC-10 in k 67,7 53,4 42,3 33,9 27,3 22,1 18,0 15 20 25 30 35 40 45 50 55 60

2,9 2,4 2,0 1,7 1,4 1,1 1,0 0,8 0,7 0,6

7.6 Electrical connection

14,9 12,1 10,0 8,4 7,0 5,9 5,0 4,2 3,6 3,1

The temperature sensors to be connected to the heat pump manager shall correspond to those in Fig. 7.1 on pag. 11 sensor characteristics shown. The only exception concerns the external temperature sensor that is in the liver size of the heat pump (see Fig. 7.2 on page 11)

7.6.1 General

All electrical connection work may be carried out only by an electrician or a person trained for the activity in question, taking into account:

Diagram . .
Diagram . .

land specific installation requirements (e.g. VDE 0100),

technical connection conditions of the energy undertaking; and

the network operator (e.g. TAB) and

The Commission is also aware of the difficulties encountered in implementing this directive.

To ensure the frost protection function of the heat pump, the heat exchanger manager shall not be switched off and flow through the heat pumps must take place.

The switch contacts of the output relays are unobstructed. Therefore, a voltage is measurable (depending on the internal resistance of a measuring instrument) even in non-closed contacts; however it is much lower than the power supply.

%XLWHQWHPSHUDWXXU>&@

Fig. 7.1Footer characteristic NTC-10

The control clamps N1-J1 to N1- J11; N1-j19; N1-J20; N1/ J23; N2-J24 and the terminal strip X3 are equipped with an extra low voltage. If a wiring error is placed on these clamps, this destroys the heat pump manager.

Diagram . .
Diagram . .

7.6.2 Electrical connection work

1) The 5-arterial electric cable for the power part of the heat pump is fed from the flow meter of the pump through the energy-business blocking (if required) into the heat pumps. Connection of the power cable to the heat pump switch box via the clamps X1: L1/L2/L3/N/PE. The heat pump voltage supply shall be provided with an alpage cut-off of at least 3 mm contact opening distance (e.g. an energy-operated lock or power switch) and an alpogen power switch with one off for all external cables (switching off current and characteristic according to device information).

Fig. 7.2Footer characteristic NTC-2 according to DIN 44574 outdoor temperature sensor

www.dimplex.de 452236.66.01 · FD 9206 EN-11

Show 5 more labels / short text on this page
Outside temperature (R1) included · Hot water temperature (r3) built-in · balcony) mounting · installation and instructions, · local conditions
Page 14 of the Dimplex SIW 11TU user manual — EN-12 452236.66.01 · FD 9206 www.dimplex.de
Page 14 · click to enlarge
Page 14

8.3 Operation of the commissioning process

The heat pump is operated via the heat pump manager.

2) The 3-arterial supply line for the heat pump manager (heat controller N1) is fed into the heat pumps. Connection of the steering line to the heat pump control cabinet via the clamps X2: L/N/PE. The heat pump's power consumption can be found in the product information or on the label plate. The cable (L/N/PE~230 V, 50 Hz) for the WPM shall be under permanent voltage and must therefore be connected before energy operation. are connected to the household current, otherwise important security functions will be out of operation during energy-locking.

The setting of the overflow valve shall be aligned with the heating system. A wrong setting can lead to different types of malfunctions and increased electrical energy needs. To properly set the overflow valve, we recommend to act as follows:

Close all heating circuits which may be closed even when the installation is working depending on its use, so that water throughput in this mode is as unfavourable as possible. These are usually the heating circuits in the rooms on the south and west side. At least one heating circuit shall be kept open (e.g. bathroom).

3. The energy-company lock (K22) with 3 main contacts (1/3/5 // 2/4/6) and an auxiliary contact (NO-contact 13/14) must be adjusted to the heat pump capacity and installed on site. The NO contact of the energy-service locking device (13/14) is pushed from the clamping strip X3/G to the clamp X3/A1. WATCH THIS! Extra low voltage! The contactor is incorporated into the power distribution. The power cable for the built-in radiator must be installed and secured according to applicable standards and regulations.

The overflow valve shall be opened so far that the current heat source temperature results in the maximum temperature difference between heating pre- and return specified in the table below. The temperature difference shall be measured as close to the heat pump as possible. In the case of mono-energy installations, the heating element shall be deactivated during commissioning.

4. All installed electrical lines must be made as durable and sturdy wiring.

Heat source

max. temperature difference between heating front and -

temperature

5. The outer sensor (R1) is clamped to the clips X3/GND and X3/ R1.

return from to

-5 °C 0 °C 10 K

1 °C 5 °C 11 K

8 Entry into service

6 °C 9 °C 12 K

10 °C 14 °C 13 K

15 °C 20 °C 14 K

8.1 General

21 °C 25 °C 15 K

For commissioning according to the requirements, it must be carried out by a factory-competent service. Under certain conditions, the guarantee is extended (cf. Guarantee fee).

8.2 Preparation

Before commissioning, the following points shall be checked:

All connections of the heat pump must be mounted

be as described in Chapter 7.

The heat source system and the heating circuit shall be:

are filled and checked.

Filter and ventilator should be located in the glycol water inlet of the

heat pump is built in.

In the glycol water and heating circuit, all

slides which could impede the correct flow of flows are open.

The heat pump manager shall, according to the corresponding

instructions for use of the hydraulics present.

EN-12 452236.66.01 · FD 9206 www.dimplex.de

Page 15 of the Dimplex SIW 11TU user manual — www.dimplex.de 452236.66.01 · FD 9206 EN-13
Page 15 · click to enlarge
Page 15

9 Maintenance / cleaning

9.3 Cleaning on the side of the heat source

9.1 Maintenance

In order to avoid operational failures caused by the accumulation of dirt in heat exchangers, it is necessary to ensure that no dirt can enter the heating system and heater. If such malfunctions occur, the installation shall be cleaned as described below.

One day after commissioning, the filter sieve shall be cleaned. Further checks should be determined according to the degree of pollution. If there is no more contamination visible, the filter sieve can be dismantled to reduce pressure loss.

9.2 Heating side cleaning

Especially when using steel components, oxygen in the heating water cycle can cause oxidation products (rust). The rust enters the heating system via valves, circulation pumps or plastic pipes. Therefore, a diffusion-proof installation should be considered - particularly in the case of underfloor heating pipes.

10 Malfunctions / malfunction diagnosis

This heat pump is a quality product that must work without interference. If a malfunction occurs, it is displayed on the heat pump manager display. To this end, see the page Failure and Disturbance in the instructions for use of the heat pump manager.

If you cannot fix the malfunction yourself, please inform the competent service.

Also residues of lubricating and sealing agents can pollute the hot water.

If the pollution is such that it impedes the performance of the condenser in the heat pump, an installer shall clean the installation.

Based on the current state of knowledge, we recommend cleaning with 5% phosphoric acid or, if more frequent cleansing is required, by 5% formic acid.

In both cases, the cleaning solution should be at room temperature. It is advisable to rinse the heat exchanger against normal flow direction.

11 Decommissioning/disposal of waste

To prevent acidic cleaning from entering the heating system cycle, we recommend that the washing machine be connected directly to the pre-flow and return of the condenser. Afterwards, rinse thoroughly with appropriate neutralising agents to prevent damage caused by any residual cleaning agent.

Before disassembling the heat pump, the machine shall be voltage-free with all valves closed. The heat pump shall be disassembled by specialist personnel. Environmentally relevant requirements waste recovery, recycling and disposal of components and components according to the usual standards must be respected. This is particularly true for the competent removal of coolant and cooling oil.

Acids should be used with caution and appropriate requirements observed.

In case of doubt, the manufacturer of the cleansing agent shall be consulted!

www.dimplex.de 452236.66.01 · FD 9206 EN-13

Page 16 of the Dimplex SIW 11TU user manual — EN-14 452236.66.01 · FD 9206 www.dimplex.de
Page 16 · click to enlarge
Page 16

12 Device Information

1 Types of sales description SIW 6TU SlW 8TU SIW 11TU

2 Construction

Heat source Glycolwater Gly Col Water GlycoIwater

2.1 Implementation Compact Compact

2.2 Controller WPM EconPlus

2.3 Heat volume counter Integrated integrated

2.4 Place of establishment Inside

2.5 Power levels 1 1 1

3 Limit of use

3.1 Heating water flow °C 20 tot 62 ± 2 20 tot 62 ± 2 20 tot 62 ± 2

3.2 Glycol water (heat source) °C -5 to 25 -5 until 25 - 5 to 25

3.3 Antifreeze Monoethylene

3.4 Minimum concentration of glycol water (-13 °C freezing temperature) 25% 25% 25%

4 Flow/sound

4.1 Heating water flow at internal pressure differential

after 14511 m3/h / Pa

Minimum m3/h / Pa

4.2 Glycol water flow rate at internal pressure differential (heat source) m3/h / Pa 1,45 / 17200 1,9 / 11200 2,6 /17500

4.3 Sound power according to EN 12102 dB(A) 46 46 47

4.4 Sound pressure at 1 m distance1 dB(A) 34 34 35

4.5 Free compression heating pump Pa 52000 44000 22000

4.6 Free compression glycol water pump Pa 45000 48000 31000

5 Dimensions, connections and weight

5.1 Device dimensions2 h x w x d mm 2000 590 x 730 2000 590 x 730 2000 590 x 730

5.2 Weight of transport unit/units incl. packaging/filled kg 210 / 382 217 / 390 230 / 404

5.3 Heating inch power connections G 11⁄4" outside G 1⁄4" out of G 1 1/2⁄4 "

5.4 Heat source inch adjustment connections G 11⁄4" outside G 1⁄4" out of G 1 1/2⁄4 "

5.5 Cooling agent; total filling weight type / kg R410A / 2,5 R410A / 2,9 R410A / 3,3

5.6 Lubricant; total capacity type / liter Polyol ester (POE) / 0,7 Polyolester (POA) / 1,2 Polyol esters (POe) / 1.2

5.7 Volume of heating water in unit liter 2,8 2,8 3,4

5.8 Volume of heat carrier in unit liter 3,0 3,6 4,5

6 Electrical connection

6.1 Power supply / fuse (common power supply WP and 2nd WB) 3~/N/PE 400 V (50 HZ) /C16A

3~/N/PE 400 V (50 HZ) /C16A

3~/N/PE 400 V (50 HZ) /C20A

6.2 Flame on separate power supplyWP / 2E WB C10A / B10A C10 A / B 10A C 10A /B10A

6.3 Steering voltage / fuse 1~/N/PE 230 V (50 HZ) /C13A

1~/N/PE 230 V (50 HZ) /C13A

1~/N/PE 230 V (50 HZ) /C13A

6.4 Degree of protection according to EN 60 529 IP 21 IP 21 IP 21

6.5 Current current m. softstarter A 28 (without soft starter) 17 20

6.6 Nominal consumption B0 / W35 / max. recording3 kW 1,30 / 2,6 1,67 / 3,2 2,22 / 4,3

6.7 Nominal current B0 / W35 / cos A/ -- 2,35 / 0,8 3,01 / 0,8 4,01 / 0,8

6.8 Power intake compressor protection (per compressor) W -- -- --

6.9 Power consumption heating circulation pump W max. 70 max. 70 max. 70

6.10 Power intake glycol water pump W max. 70 max. 70 max. 70

6.11 Electric radiator (2nd heat source) kW 2.4 or 64 2.4 respectively 64 2.4 respectively 64

EN-14 452236.66.01 · FD 9206 www.dimplex.de

Show 16 more labels / short text on this page
WPM EconPlus · WPM EconomPlus · integrated · integrated * Monoethylene · Monoethylene * glycol · glycol ·glycol · glycol * 1.05 / 14100 · 1.4 / 21600 · 1.9 / 25100 · 0.55 / 5000 · 0.7 / 8000 · 0.9 / 4700
Page 17 of the Dimplex SIW 11TU user manual — www.dimplex.de 452236.66.01 · FD 9206 EN-15
Page 17 · click to enlarge
Page 17

7 meets the European safety requirements see CE declaration of conformity

8 Other implementation features

8.1 Water in apparatus protected against frost 5 Yes yes yes yes

8.2 max. working pressure (heat source/cooling plate) bar 3,0 3,0 3,0

9 Hot water boiler Material according to

EN 1.4162 EN 1.4162 EN 1.4162

9.1 Net content of litres 170 170 170

9.2 Surface heat exchanger m2 2,2 2,2 2,2

9.3 Heat loss at 50 °C boiler temperature 20 °C room temperature kW/h24h 0,86 0,86 0,86

9.4 Slide volume (without reheating)6 litres 207 207 207

10 Heat output / performance 3 EN 14511 EN 145 11 EN 145 11.

at B-5 / W45 kW / --- 5,0 / 3,1 6,5 / 3,1 9,1 / 3,2

at B0 / W55 kW / --- 5,5 / 2,8 7,2 / 2,8 10,0 / 2,8

at B0 / W45 kW / --- 5,8 / 3,6 7,5 / 3,6 10,4 / 3,6

at B0 / W35 kW / --- 6,1 / 4,6 8,1 / 4,7 10,9 / 4,8

1. The sound pressure level indicated corresponds to the operating noise of the heat pump in heating mode at 35 °C preliminary running temperature. The sound pressure level indicated shall constitute the level in the free field. Depending on the installation site, the measurement value can be max. 16 dB (A)
2. Please note that the space required for pipe connection, operation and maintenance is larger.
3. This data describes the installation's dimensions and performance capability according to EN 14511. Economic and energy calculations should take into account the bivalentity point and regulation factors. This data is only achieved with clean heat exchangers. Instructions for maintenance, commissioning and operation can be found in the relevant sections of the assembly instructions. For example, this means: A7 / W35: heat source temperature 7 °C and preflow temperature heating water 35 °C.
4. Delivery condition 6 kW,
5. The heating circulation pump and the heat pump manager must always be ready for operation.
6. Mixing water temperature 38 °C and boiler temperature 45 °C.

www.dimplex.de 452236.66.01 · FD 9206 EN-15

see CE declaration of conformity · see CE statement of conformity

Page 18 of the Dimplex SIW 11TU user manual — EN-16 452236.66.01 · FD 9206 www.dimplex.de
Page 18 · click to enlarge
Page 18

EN-16 452236.66.01 · FD 9206 www.dimplex.de

Page 19 of the Dimplex SIW 11TU user manual — 6 Declaration of conformity A-XXI
Page 19 · click to enlarge
Page 19

1 Maatschets A-II

2 Diagrams A-III

2.1 Characteristics SIW 6TU A-III 2.2 Characteristics SIw 8TU A -IV 2.3 Characteristics SI W 11TU A/V 2.4 Border diagram A-VI

3 Electric diagram gauge hydraulic module A-VII

3.1 Steering A-VII 3.2 Sturdy A-VIII 3.3 Power A-IX 3.4 Connection diagram A-X 3.5 Connectivity scheme A- XI 3.6 Legend A-III II

4 Electric diagram heat pump module A-XIV

4.1 Steering A-XIV 4.2 Power A- XV 4.3 Connection diagram A-xvi 4.4 Legend A- xVII

5 Hydraulic connection diagram A-XVIII

5.1 Connection scheme for a heating circuit with underfloor heating and room temperature control via Smart RTC, hot water preparation A-XVIII 5.2 Connecting schedule for a heat ring with series switched buffer tank and warm water preparationA-XIX 5.3 Legend A-XX

6 Declaration of conformity A-XXI

www.dimplex.de 452236.66.01 · FD 9206 A-I

Page 20 of the Dimplex SIW 11TU user manual — A-II 452236.66.01 · FD 9206 www.dimplex.de
Page 20 · click to enlarge
Page 20

1 Size sketch

Diagram . .
Diagram . .

A-II 452236.66.01 · FD 9206 www.dimplex.de

Page 21 of the Dimplex SIW 11TU user manual — A-XII 452236.66.01 · FD 9206 www.dimplex.de
Page 21 · click to enlarge
Page 21

3.6 Legend

A1 Bridge Energy Business Blocking: must be placed if no energy business lock is available (contact open = power operation block) A2 Bridge Blocking - must be removed when the input is used (opening = WP blocked). A7.1/2 Bridge E10.1: by removing a bridge, the power decreases with 2 kW A11 Bridge solar energy: when using a solar module, the bridge must be removed and the contact points connected to the solar module. A - R2 Bridge return sensor: - shall be moved when a differential pressure-free distributor and a fuse-warming circuit reverse valve is used. New contact points: X3/1 and X3/2

B2* Pressostat low pressure primary circuit B3* Thermostat hot water B4 Thermostate pool water B5* Thermostate E10

E9* Immersion resistance hot water E10* 2. Heat source 2,4 or 6 kW

F2 Power supply fuse for plug-in plugs J12; J13 and J21 5x20 / 4.0 AT F3 Power supply circuit fuse J15 to J18 and J22, 5x 20 / 4,0 AT F10.1* Flow switch primary circuit F10.2* Flow switches secondary circuit F15 Engine protection M11 F17 Safety temperature limiter E10.1

F26 Engine protection M16 H5* Light distance indication malfunction

J1 Voltage supply N1 J2 - 3 Analog inputs J4 Analog outputs J5 Digital inputs J6 Analog exits J7 - 8 Digital inputs j9 free J10 Control panel J11 free J12 - J18 230 V AC - Outputs for control of system components J19 Digital inputsJ20 Analog inputs; analogue inputs; digital inputs J21 - J22 Digital outputsJ23 Bus connection to modules J24 Voltage device for components

K1 Contactor M1 K20* Contactor E10.1 K21* Contactors E9 K22* Energy control lock-in K23* Auxiliary relay for locking input K31.1* Requesting circulation hot water M1 Compressor M11 Primary circulating pump M13* Heating circulation pump M15* Heatation circulation pump 2nd circuit M16 Additional circulation pump m21* Mixer main or 3rd ring M22* Mixers 2nd heat circuit [M19]* Swimming pool water circulation pump [M24]* Circulation pump warm water

N1 Control unit field card Interface to N23 N14 Control panel N17* pCOe module N20* Heat volume counter N23* Electronic expansion valve control E*V connection (1=green, 2=yellow, 3=brown, 4=white) N24* Smart - RTC

R1* External sensor R2 Return sensor heating circuit R2.1* Return sensor heat circuit in differential pressureless distributor R3 Hot water sensor R5* Footer for 2nd ring R6 Front sensor primary cycle R7 Coder resistance

A-XII 452236.66.01 · FD 9206 www.dimplex.de

Page 22 of the Dimplex SIW 11TU user manual — www.dimplex.de 452236.66.01 · FD 9206 A-XIII
Page 22 · click to enlarge
Page 22

R9 Front sensor heating circuit R13 Footer renewable, space sensor, feel 3rd heat circuit R24 Returns sensor primary circuit

T1 Safety Transformer 230/24 V AC

X1 Clamping strip power supply E10 X1.1 Plug power voltage X2 Clamps strip voltage = 230 V AC circuit breaker X3 Clips strip extra low voltage < 25 V AC Switch box X5.1 Bus divider clamp among others. for N24 X7 Clamping strip power adjustment E10.1 X12 Plug steering voltage 230 V X13 Plugging extra low voltage

www.dimplex.de 452236.66.01 · FD 9206 A-XIII

Page 23 of the Dimplex SIW 11TU user manual — A-XIV 452236.66.01 · FD 9206 www.dimplex.de
Page 23 · click to enlarge
Page 23

4 Electric diagram heat pump module

4.1 Sturdyness

Diagram . .
Diagram . .

A-XIV 452236.66.01 · FD 9206 www.dimplex.de

Page 24 of the Dimplex SIW 11TU user manual — www.dimplex.de 452236.66.01 · FD 9206 A-XV
Page 24 · click to enlarge
Page 24

4.2 Power

Diagram . .
Diagram . .

www.dimplex.de 452236.66.01 · FD 9206 A-XV

Page 25 of the Dimplex SIW 11TU user manual — A-XVI 452236.66.01 · FD 9206 www.dimplex.de
Page 25 · click to enlarge
Page 25

4.3 Connection scheme

Diagram . .
Diagram . .

A-XVI 452236.66.01 · FD 9206 www.dimplex.de

Page 26 of the Dimplex SIW 11TU user manual — www.dimplex.de 452236.66.01 · FD 9206 A-XVII
Page 26 · click to enlarge
Page 26

4.4 Legend

F24 High pressure pressostat F5 Low pressure pressostaat F7 Hot gas thermostat F12 Malfunction notification contact

M1 Compressor M7 Actuator for expansion valve

N1* Heat pump manager N7 Softstart control N23* Control electronic expansion valve E*V connection (1=green, 2=yellow, 3=brown, 4=white) R25 Pressure sensor cooling cycle - low pressure po R26 Pressure sensor cool circuit - high pressure PC R27 Suction gas sensor

T1 Safety Transformer 230/24 V AC

W1* Heat pump connection line - manager 230 V W2* PHP interconnection line - Manager

X1.1 Power supply voltage plug X2 Clamping strip voltage = 230 V AC X3 Clip-band extra low voltage < 25 V AC x12 Plug 230 V steering voltage X13 Plugger extra low steering voltage * Components must be connected / made available on site In the factory wired Can be connected by customer if desired

www.dimplex.de 452236.66.01 · FD 9206 A-XVII

K1 Contactor M1

Page 27 of the Dimplex SIW 11TU user manual — A-XVIII 452236.66.01 · FD 9206 www.dimplex.de
Page 27 · click to enlarge
Page 27

5 Hydraulic connection diagram

5.1 Connection scheme for a heating circuit with underfloor heating and room temperature control via Smart RTC, hot water preparation

Diagram . .
Diagram . .

A-XVIII 452236.66.01 · FD 9206 www.dimplex.de

Page 28 of the Dimplex SIW 11TU user manual — www.dimplex.de 452236.66.01 · FD 9206 A-XIX
Page 28 · click to enlarge
Page 28

5.2 Connection scheme for a heating circuit with series-switched buffer tank and hot water preparation

Diagram . .
Diagram . .

www.dimplex.de 452236.66.01 · FD 9206 A-XIX

Page 29 of the Dimplex SIW 11TU user manual — M13 Heating circulation pump
Page 29 · click to enlarge
Page 29

5.3 Legend

M13 Heating circulation pump

N1 Heat pump manager

R1 External temperature sensor

A-XX 452236.66.01 · FD 9206 www.dimplex.de

Show 10 more labels / short text on this page
Valve valve · Safety valve combination · Circulation pump · Expansion drum · Room temperature controlled valve · Fan with micro bubble air separator · Heat user · Temperature sensor · Buffer tank
Page 30 of the Dimplex SIW 11TU user manual — www.dimplex.de 452236.66.01 · FD 9206 A-XXI
Page 30 · click to enlarge
Page 30

6 Declaration of conformity

EC - Declaration of conformity EC Declaration of Conformity Déclaration de conformité CE

I, the undersigned Glen Dimplex Deutschland GmbH The signed Geschäftsbereich Dimplex Löjentreprise soussignée, Am Goldenen Feld 18 D - 95326 Kulmbach

confirms that the apparatus/devices listed below comply with the applicable EC directives listed below. This declaration shall cease to be valid at the time of any change in the device or devices.

hereby certificates that the following device(s) complies/comply with the applicable EU directives. This certification losses its validity if the device(s) is/are modified.

certified par la présente que le(s) appareil(s), décrit(s). ci-dessous sont conformes aux directives CE afférentes. Toute modification effectuée sur löjna(les) appareil(s) entraîne lövnaance de la validité de cette déclaration.

Nameheat pumps Designation: Heat pumps Désignation : Pompes à chaleur
TypeSIW 6TU Type(s): Slide 8TU Type (s): SIW 11TU

EC Directives Low voltage Directive 2006/96/EC EMC Directive 2004/108/EC Pressure equipment Directive 97/23/EC

EC Directives Low voltage directive 2006/95/EC EMC directive 2004/108/EC Pressure equipment directive 97/23/EC

Directives CEE Direct Basse Tension 2006/95/CE Directive CEM 2004/108/CE Directive Équipement Sous Pressure 97/23/CE

Applied standards Applied standard Norms appliquées

EN 60335-1+A11+A1+A12+Corr.+A2 EN 60335-1/A13 EN 60335-2-40+A11+A12+A1+Corr.+A2 EN 55014-1 EN 55014-2+A1 EN 61000-3-2 EN 61000-3-3+A1+A2 EN 378-1, EN 378-2+A1, EN 378-3, EN 378-4 EN 14511-1, EN 14511-2, EN 14511-3+AC, EN 14511-4 DIN 8901 BGR 500 (D), SVTI (CH)

Conformity assessment procedure according to the Pressure Equipment Directive:

Conformity assessment procedure according to pressure equipment directive: Module A

Procédure d'Ompément de la conformité selon la directive Équipements Sous Pressure: Module A

CE mark affixed2012
CE mark added2012
Marcage CE2012

The EC declaration of conformity has been issued.

EC declaration of conformity issued on.

La déclaration de conformité CE a été délivrée le.

www.dimplex.de 452236.66.01 · FD 9206 A-XXI

Module A

Page 31 of the Dimplex SIW 11TU user manual — 6 Declaration of conformity
Page 31 · click to enlarge
Page 31

Glen Dimplex Deutschland GmbH Geschäftsbereich Dimfix Am Goldenen Feld 18 D-95326 Kulmbach

Errors and changes reserved.

+49 (0) 9221 709 565

www.dimplex.de

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Dimplex SIW 11TU

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Dimplex SIW 11TU

Be the first to ask — other owners or our team will answer.

Original document

Dimplex SIW 11TU manual PDF

40 pages·1.9 MB·Heat Pump·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…