Mounting instructions

Ground/water heat pump for indoor installation

Order No : 452231.66.10 FD 8808

Page 2 of the Dimplex SIK 11 TE user manual
Page 2 · click to enlarge
Page 2
Page 2 of the Dimplex SIK 11 TE user manual
Page 4 of the Dimplex SIK 11 TE user manual — NL-2
Page 4 · click to enlarge
Page 4

1 Read directly please

1.2 Legal requirements and guidelines

1.1 Key clues

The construction and execution of the heat pump comply with all corresponding EC directives (see CE declaration of conformity).

The electrical connection of the heat pump shall comply with the corresponding EN and IEC standards as well as national guidelines. Furthermore, the connection conditions of energy supply companies must be respected.

WATCH OUT! Do not lift the device at the holes in the cover plates!

The heat pump shall be integrated into the heating system in accordance with the relevant requirements.

Persons, especially children, who are unable to use the apparatus safely due to their physical, sensory or mental skills or because of lack of knowledge or experience, shall not be allowed to use it without supervision or instructions from a responsible person.

Don't let children go unsupervised to make sure they don't play with the plane.

1.3 Energy saving use of the heat pump

By using this heat pump you contribute to the stool of our environment. For efficient operation, careful dimensioning of the heating system and its heat source is very important. Particular attention should be paid to the minimum departure temperature of water. Therefore, all connected energy users should be suitable for a low departure temperature. A 1 K higher heating water temperature increases energy consumption by approx. 2.5%. Low temperature heating with starting temperatures between 30 °C and 50 °C is suitable for energy saving.

NL-2

Page 5 of the Dimplex SIK 11 TE user manual — www.dimplex.de NL-3
Page 5 · click to enlarge
Page 5

2 Purpose of use of the heat pump

3 Basic device

The base unit consists of a compact heat pump for installation inside. In addition to the control panel with integrated controller, it already contains important modules of heating and glycol water circuit:

2.1 Scope

The ground water heat pump can be used in existing or newly installed heating installations. The heat carrier in the thermal source installation is glycol water. The heat source may be used as earth dons, collectors or similar installations.

2.2 Method of working

The coolant R407C is done in the cooling cycle. The coolant R407C is CFC free, does not break down ozone and is not flammable.

The earth stores the warmth of the sun, wind and rain. This geothermal heat is in the earth collector, the Earth probe and so on. absorbed by the glycol water at a low temperature. A circulating pump then transports the "heated" glycol water to the vaporizer of the heat pump. This heat is transferred to the coolant in the cooling cycle. The glycol water cools off again, so that it can absorb heat energy back into the glycol water cycle.

All components necessary for the operation of the heat pump are installed on the switch panel. The voltage input for the ballast and steering current shall be installed on site.

The collector with the glycol water circuit divider shall be installed on site.

The coolant is sucked in by the electrically driven compressor, compressed and pumped to a higher temperature level. The electrical energy supplied in this process is not lost, but is largely transferred to the coolant.

Dimplex SIK 11 TE — 2.2 Method of working diagram (page 5)
Fig. 2 · 2.2 Method of working

Then the coolant enters the condenser and here again transfers its heat energy to the heating water. Depending on the operating point, heating water can be heated to 60 °C.

1. Switch Panel
2. Circulation pumps
3. Condensor
4. Compressor
5. Vadiator
6. Expansion vessel

www.dimplex.de NL-3

Show 5 more labels / short text on this page
• Expansion vessels · • Circulation pumps · ♪ Pressure relief valves · ■ Manometer · ► Overflow valve (heating circuit)
Page 6 of the Dimplex SIK 11 TE user manual — NL-4
Page 6 · click to enlarge
Page 6

4 Accessories

6 Placement

4.1 Glycol water distributor

6.1 General instructions

The glycol water distributor unites the collector loops of the heat source system into one main line, which is connected to the heat pump. The integrated ball valves can be used to close separate glycol water circuits for venting.

The device shall be placed in interior spaces on a smooth, smooth and horizontal surface. The frame must be close to the ground in order to ensure appropriate sound insulation. If not, additional noise-reducing measures may be necessary.

Diagram . .
Diagram . .

The heat pump shall be so designed that service to the device can be performed without any problems. This is guaranteed if there is a distance of approx. 1 m in front and side of the heat pump.

Diagram . .
Diagram . .

4.2 Glycol waterpressostat

If required by the government, a low pressure pressostat for glycol water may be incorporated into the apparatus. In this case, the intended connection above the glycol water expansion vessel shall be used.

5 Transport

6.2 Noise emissions

A lift truck is suitable for transport over a solid surface. If the heat pump is to be transported on an uneven surface or over stairs, it can be carried with straps. These can be placed directly under the transport pallet.

Thanks to the effective sound insulation, the heat pump works very quietly. Audio transmission to the foundation or base the heating system is highly prevented by internal decoupling measures.

Diagram . .
Diagram . .

In order to illuminate the device without pallet, drill holes fitted sideways in the frame must be used. The lateral cover plates shall be removed. A regular tube can be used as a support.

WATCH OUT! Do not lift the device at the holes in the cover plates!

NL-4

Page 7 of the Dimplex SIK 11 TE user manual — www.dimplex.de EN-5
Page 7 · click to enlarge
Page 7

7 Assembly

The hydraulic basic diagram must be observed.

The supplied filter and the included separator of microair bubbles must be mounted on site in the glycol water input of the heat pump.

7.1 General

The heat pump shall be equipped with the following connections:

The glycol water shall be produced before filling the installation. The glycol water concentration shall be at least 25%. This ensures a frost freeness to -14 °C.

. Departure of heating and hot water preparation

. Common back-up heating and hot water preparation

Only monoethylene glycol or propylene glycol-based antifreeze agents may be used.

The heat source system shall be ventilated and checked for density.

. . Connection for additional expansion vessel (if necessary)

. . Draining of pressure relief valves

7.2 Connection to heating

The heat pump is equipped with separate outputs for the heating and hot water cycle.

7.4 Electrical connection

The following electrical connections shall be made on the heat pump.

If the heat pump does not provide heating, the hot water outlet shall be permanently sealed.

. . Connection of the power cable to the switch panel

of the heat pump.

For hot water-sided heat pump connection, the heating system should be flushed down to allow possible dirt, residual insulation material etc. to be removed. If the condenser is blocked by waste and contamination, this may lead to a failure of the heat pump.

. . Connection of the steering voltage line to the heat pump switch panel.

All electrical components necessary for the operation of the heat pump are located on the switch panel.

For installations with a lockable heating water outlet, depending on radiator or radiator Thermostat valves, is an overflow valve built in. This ensures a minimal flow of hot water through the water pump and prevents interference.

Exact instructions on the connection of external components and the functioning of the heat pump controller can be found in the device's connecting schedule and the attached control manual.

The connection of the power cable is done via the clamps X1: L1/L2/L3/PE on the switch panel.

After installation of the heating system, it is necessary to fill up and air out and put pressure on.

An alpuge cut-off with minimum 3 mm contact opening distance (e.g. The electrical control switch or safety contact) and a 3-pole power switch with one off for all external cables must be fitted. The necessary cable diameter should be determined in accordance with the heat pump consumption, technical connection conditions of the electricity company concerned and applicable rules. The heat pump consumption can be found in the product information or on the label plate. The clamps are for a cable diameter of max. 10 mm2 designed.

Prince security in case of frost risk

If the regulators and heating circulation pumps are ready to operate, then the frost protection of the regulator works. The installation shall be emptied if the heat pump is shut down or if power failure occurs. In the case of heat pump systems where power failure cannot be recognised (holiday home), the heating circuit with an appropriate frost protection shall be used.

The integrated expansion vessel has a volume of 24 litres. This volume is suitable for buildings with a heated living space up to 200 m2.

The volume must be checked by the person who plans the installation. An additional expansion vessel may need to be installed (according to DIN 4751 part 1). Tables in the catalogues of manufacturers facilitate dimensioning to water content from installation.

The steering voltage is connected to the clamps X1: L/N/PE.

If a glycol water pump is required to be stronger than the integrated one, an engine contactor and an appropriate motor safety switch shall be fitted. The safety switch shall then be connected to the clamps for the internal glycol water pump (controllant clamp J12/N03 and X1-N). The power supply of the larger pump must then be done via the feeding grid.

7.3 Connection to heat source

The connection shall be performed as follows:

Connect the glycol water line to the departure and the return of the heat pump.

www.dimplex.de EN-5

Show 4 more labels / short text on this page
• Departure/reversion glycol water system · • Reflow overflow valve · ♪ Condensate drain · .
Page 8 of the Dimplex SIK 11 TE user manual — NL-6
Page 8 · click to enlarge
Page 8

8 Entry into service

8.3 Operation of the commissioning process

The heat pump is operated via the heat pump controller.

8.1 General

For commissioning according to the requirements, it must be carried out by a factory-competent service department. Under certain conditions, an extension of the guarantee is required (if applicable). Guarantee fee).

The power level of the circulating pump shall be adjusted to the heating system.

8.2 Preparation

The overflow valve shall be adjusted to the heating system. A wrong setting can lead to faulty operation and increased electrical energy needs. To properly adjust the flood valve, we recommend to act as follows:

Before commissioning, the following points shall be checked:

. . All connections of the heat pump must be mounted

(see Chapter 7).

Close all heating circuits, which may be closed even when the installation is working depending on its use, so that water throughput in this mode of operation is as unfavourable as possible. These are usually the heating circuits in the rooms on the south and west side. At least one heating circuit must be kept open (e.g. bath).

. The heat source system and the heating circuit shall be:

are filled and checked.

• Filter and ventilator should be in the glycol water inlet of the

heat pump is built in.

• In the glycol water and heating circuit, all

The system is designed to be capable of providing a high level of protection against the risks of damage caused by fire.

The excess flow valve shall be opened so far that the current heat source temperature results in a maximum temperature difference between heating departure and return as specified in the table below. The temperature difference shall be measured as close to the heat pump as possible. In the case of mono-energy installations, the heating element shall be deactivated.

. The heat pump regulator shall be according to the corresponding

instructions for use are in line with the heating system.

• The condensation water must be able to run unhindered.

. The drain of the glycol water and heating water pressure valve shall be ensured.

Heat source temperatureMax. temperature difference between heating room and cooling run-off ofto -5° C0° C10 K 1° C5° C11 K 6° C9° C12 K 10° C14° C13 K 15° C20° C14 K 21° C25° C15 K

Malfunctions in a working installation are displayed on the heat pump controller and can be corrected as described in the instructions for use of the heat pumps regulator.

NL-6

Page 9 of the Dimplex SIK 11 TE user manual — www.dimplex.de EN-7
Page 9 · click to enlarge
Page 9

9 Maintenance / cleaning

10 Malfunctions / malfunction diagnosis

9.1 Maintenance

This heat pump is a quality product that must work without interference. If a malfunction occurs, it is displayed on the heat pump manager display. To this end, see the page Failure and Disturbance in the instructions for use of the heat pump manager.

The heat pump is maintenance-free. In order to prevent operational failures caused by the accumulation of dirt in heat exchangers, it is necessary to ensure that no dirt can enter the heating system and the heating installation. If such malfunctions occur, the installation shall be cleaned as described below.

If you cannot fix the malfunction yourself, please inform the competent service department.

9.2 Cleaning of heating area

Especially when using steel components, oxidation products (rust) can be produced by oxygen in the hot water cycle. The rust enters the heating system via valves, circulation pumps or plastic pipes. Therefore, a diffusion-proof installation should be considered - particularly in the case of underfloor heating pipes.

11 Decommissioned/removal

Before disassembling the heat pump, the machine must be voltage-free and all valves closed. Environmentally relevant requirements waste recovery, recycling and disposal of waste and components should be respected according to normal standards. This is particularly true for the competent removal of coolant and cooling oil.

Also residues of lubricating and sealing agents can pollute the hot water.

If the pollution is so high that the capacity of the condenser in the heat pump is reduced, an installer shall clean the installation.

According to current knowledge, we recommend cleaning with a 5% phosphoric acid or, if more frequent cleansing is required, with a 5 percent formic acid.

In both cases, the cleaning solution should be at room temperature. It is advisable to rinse out the heat exchanger against normal flow direction.

To prevent acidic cleaning from entering the heating system cycle, we recommend that the washing machine be connected directly to the departure and backflow of the condenser. Afterwards, rinse thoroughly with appropriate neutralising agents to prevent damage caused by any residual residue of a cleansing agent.

Acids should be used with caution and appropriate requirements observed.

In case of doubt, the manufacturer of the cleansing agent shall be consulted!

9.3 Heat source-side cleaning

One day after the filter is in operation, the filter sieve must be cleaned and then it must be done weekly. If there is no more visible contamination, the filter sieve can be dismantled to reduce pressure loss.

www.dimplex.de EN-7

Page 10 of the Dimplex SIK 11 TE user manual — NL-8
Page 10 · click to enlarge
Page 10

12 Device Information

1 Technical and commercial nameSIK 7TESIK 9TESIK 11TESIK 14TE 2 Construction 2.1 ImplementationCompactCompactCompactCompact 2.2 Degree of protection according to EN 60 529IP 20IP 20IP 20IP 20 2.3 Place of establishmentEnterEnterEnterEnter 3 Power data 3.1 Temperature usage limits: Heating water-departure temperature °Cup to 58up to 58up to 58up to 58 Glycol water (heat source) °C-5 to +25-5 to +25-5 to +25-5 to +25 AntifreezeMonoethylene glycolMonoethylene glycolMonoethylene glycolMonoethylene glycol Minimum glycol water content (-13°C freezing temperature)25%25%25%25% 3.2 Temperature difference hot water at B0 / W35 K9,95,010,55,010,15,09,65,0 3.3 Heating power/power coefficient (COP) at B-5 / W55 1 kW / ---5,6 / 2,27,7 / 2,39,4 / 2,412,5 / 2,6 at B0 / W45 1 kW / ---6,6 / 3,08,7 / 3,211,2 / 3,214,1 / 3,5 at B0 / W50 1 kW / ---6,7 / 2,99,0 / 3,111,3 / 3,014,2 / 3,4 at B0 / W55 1 kW / ---6,9 / 4,36,8 / 4,19,2 / 4,49,0 / 4,211,8 / 4,411,7 / 4,214,5 / 4,514,4 / 4,3 3.4 Noise level dB(A)51515151 3.5 Heating water flow at internal pressure differential m3/h / Pa0,6 / 25001,2 / 116000,75 / 45001,6 / 205001,0 / 35002,0 / 148001,3 / 35002,5 / 16500 3.6 Free compression heating circulation pump (mode 3) Pa4750030400435001850065500482006450042500 3.7 Glycol water flow rate at internal pressure differential (heat source) m3/h / Pa1,7 / 100001,6 / 93002,3 / 160002,2 / 150003,0 / 130002,7 / 114003,5 / 130003,3 / 11600 3.8 Free compression glycol water pump (mode 3) Pa5500056200440004600040000446003400038400 3.9 Cooling agent; total filling weight type / kgR407C / 1,5R407C / 1,8R407C / 2,0R407C / 2,3 4 Dimensions, connections and weight 4.1 Dimensions of the device without connections2 H x W x L mm1115 × 652 × 6881115 × 652 × 6881115 × 652 × 6881115 × 652 × 688 4.2 Heating inch gear connectionsR 11⁄4' aR 11⁄4' aR 11⁄4' aR 11⁄4' a 4.3 Heat source inch power connectionsR 11⁄4' aR 11⁄4' aR 11⁄4' aR 11⁄4' a 4.4 Weight of transport unit/ units incl. packaging kg179180191203 5 Electrical connection 5.1 Nominal voltage; security V / A400 / 16400 / 16400 / 16400 / 16 5.2 Rated input power1 B0 W35 kW1,61,662,072,142,662,793,223,37 5.3 Starting current m. softstart system A30 (without soft start system)152626 5.4 Nominal current B0 W35 / cos φ A / ---2,89 / 0,83 / 0,83,77 / 0,83,86 / 0,84,84 / 0,85,03 / 0,85,81 / 0,86,08 / 0,8 6 Compliance with European safety rules3333 7 Other features of the version 7.1 Water in apparatus protected against frost4YesYesYesYes 7.2 Power levels1111 7.3 Internal / External Controllerinternalinternalinternalinternal
1. This data represents the size and efficiency of the installation. The bivalent point and the scheme should be taken into account for economic and energy considerations. For example, this means: B10 / W55: heat source temperature 10 °C and hot water supply 55 °C.
2. Please note that the space required for pipe connection, operation and maintenance is larger.
3. See CE declaration of conformity
4. The heating circulation pump and the controller of the heat pump must always be ready for operation.

NL-8

Page 11 of the Dimplex SIK 11 TE user manual — www.dimplex.de A-I
Page 11 · click to enlarge
Page 11

1 Maatschets A-II

2 Diagrams A-III

2.1 Curves SIK 7TE A-III 2.2 Curves Sik 9TE A - IV 2.3 Curves sik 11TE A‐V 2.4 Curves SIK 14TE A/VI

3 Electric diagrams A-VII

3.1 Steering A-VII 3.2 Power A-VIII 3.3 Connection scheme A-IX 3.4 Legend A-X

4 Basic hydraulic diagram A-XI

4.1 Schematic image A-XI 4.2 Legend A- XII

5 Declaration of conformity A-XIII

www.dimplex.de A-I

Page 12 of the Dimplex SIK 11 TE user manual — A-II
Page 12 · click to enlarge
Page 12

1 Size sketch

Diagram . .
Diagram . .

A-II

Page 13 of the Dimplex SIK 11 TE user manual — www.dimplex.de A-III
Page 13 · click to enlarge
Page 13

2 Diagrams

2.1 Curves SIK 7TE

Diagram . .
Diagram . .

www.dimplex.de A-III

Page 14 of the Dimplex SIK 11 TE user manual — A-IV
Page 14 · click to enlarge
Page 14

2.2 Curves SIK 9TE

Diagram . .
Diagram . .

A-IV

Page 15 of the Dimplex SIK 11 TE user manual — www.dimplex.de A-V
Page 15 · click to enlarge
Page 15

2.3 Curves SIK 11TE

Diagram . .
Diagram . .

www.dimplex.de A-V

Page 16 of the Dimplex SIK 11 TE user manual — A-VI
Page 16 · click to enlarge
Page 16

2.4 Curves SIK 14TE

Diagram . .
Diagram . .

A-VI

Page 17 of the Dimplex SIK 11 TE user manual — www.dimplex.de A-VII
Page 17 · click to enlarge
Page 17

3 Electrical diagrams

3.1 Steering

Diagram . .
Diagram . .

www.dimplex.de A-VII

Page 18 of the Dimplex SIK 11 TE user manual — A-VIII
Page 18 · click to enlarge
Page 18

3.2 Power

Diagram . .
Diagram . .

A-VIII

Page 19 of the Dimplex SIK 11 TE user manual — www.dimplex.de A-IX
Page 19 · click to enlarge
Page 19

3.3 Connection scheme

Diagram . .
Diagram . .

www.dimplex.de A-IX

Page 20 of the Dimplex SIK 11 TE user manual — A-X
Page 20 · click to enlarge
Page 20

3.4 Legend

A1 Wirebridge, should be placed when no contactor power company closure is required A2 Wirebridge must be removed when using the 2nd blocking input B3* Thermostat hot water B4* Thermostate pool water E9* Electric. Dipped heating element hot water E10* 2. Heat source (boiler or leak. heating element) F2 Last securing for N1 relay outputs on J12 and J13 4.0 ATr F3 Last securing to N1relai outputs at J15 - J18 4.0 Atr F4 Pressostat high pressure F5 Pressure pressure H5* Light failure indicator remotely J1...J18 Clamp connector for N1, K1 Safety switch compressor K11* Electron. Relays for remote interference indication (on relay module) K12* Electron. relay for circulating pump pool water (on relay module) K20* Safety switch 2nd heat source K21* Safety switches leak. Immersion heating element hot water K22* Contactor seal electrical company safety switch K23* SPR auxiliary relay M1 Compressor M11 Primary circulation pump (glycol water) M13 Heating circulation pump M15* Heating pump 2nd circuit M16* Additional circulating pump M18* Warm water circulation pump m19* Pool water circulation pumps M21* Mixing valve main circuit M22* Mixer crane 2nd ring N1 Heat pump regulator N7 Softstart system N11* Relay module N14 Control panel R1 External temperature sensor R2 Return sensor R3 Hot water sensor (alternative for warm water thermostat) R5 Feeler for 2nd heat circuit R6 Peeler to prevent freezing R7 Coder resistance 40.2 kOHM R9 Departure sensor T1 Safety separator 230/24V AC-28VA X1 Clamp block 3LPE-400V AC-50 Hz / Net control L/N-230V AC-230 V

Abbreviations: EVB Entrance seal electricity company SPR Additional locking input, configurable MA* Mixing valve open MZ Mixing tap closed * Components should be made available externally

A-X

Page 21 of the Dimplex SIK 11 TE user manual — www.dimplex.de A-XI
Page 21 · click to enlarge
Page 21

4 Basic hydraulic diagram

4.1 Schematic image

Diagram . .
Diagram . .

www.dimplex.de A-XI

Page 22 of the Dimplex SIK 11 TE user manual — A-XII
Page 22 · click to enlarge
Page 22

4.2 Legend

Diagram . .
Diagram . .

A-XII

Show 10 more labels / short text on this page
E10 2nd heat source · M11 Primary circulation pump · M13 Heating-circulation pump · m18 Hot water circulation pump * R1 External sensor · r2 Recycler · r3 Warm water sensor · EV Power distribution · KW Cold water · WW Hot water
Page 23 of the Dimplex SIK 11 TE user manual — www.dimplex.de A-XIII
Page 23 · click to enlarge
Page 23

5 Declaration of conformity

Dimplex SIK 11 TE — 5 Declaration of conformity diagram (page 23)
Fig. 16 · 5 Declaration of conformity

www.dimplex.de A-XIII

Page 24 of the Dimplex SIK 11 TE user manual — 5 Declaration of conformity
Page 24 · click to enlarge
Page 24

Glen Dimplex Deutschland GmbH Geschäftsbereich Dimfix Am Goldenen Feld 18 D-95326 Kulmbach

Errors and changes reserved.

+49 (0) 9221 709 565

www.dimplex.de

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Dimplex SIK 11 TE

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Dimplex SIK 11 TE

Be the first to ask — other owners or our team will answer.

Original document

Dimplex SIK 11 TE manual PDF

24 pages·2.3 MB·Heat Pump·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…