Dimplex LI 16TER plus

32 pages·2.4 MB·Heat Pump·PDF·ENDEFRITNLJA
Dimplex LI 16TER plus
Table of Contents 53 sections Contents · 1 Read directly please · 1.1 Key clues · 1.2 Legal requirements and rules · … ShowHide
Page 1 of the Dimplex LI 16TER plus user manual — Order No: 452160.66.16 FD 8806
Page 1 · click to enlarge
Page 1

LI 11TER+ LI 16TER+

Diagram . .
Diagram . .
Diagram . .
Diagram . .

Reversible air/water heat pump for indoor installation

Order No: 452160.66.16 FD 8806

Page 2 of the Dimplex LI 16TER plus user manual
Page 2 · click to enlarge
Page 2
Page 2 of the Dimplex LI 16TER plus user manual
Page 4 of the Dimplex LI 16TER plus user manual — NL-2
Page 4 · click to enlarge
Page 4

1 Read directly please

1.2 Legal requirements and rules

1.1 Key clues

The construction and execution of the heat pump comply with all corresponding EC directives (see CE conformity assessment).

The electrical connection of the heat pump must comply with the corresponding EN and IEC standards as well as national guidelines. In addition, the connection conditions of energy supply companies must be respected.

When connecting the heating or heat system The Commission has also proposed that the following measures be taken:

Persons, especially children, who are unable to use the device on a safe mother or her because of their physical, sensory or mental skills or due to lack of knowledge or experience, may not use it without supervision or instruction by an responsible person.

Don't let children go unsupervised to make sure they don't play with the plane.

1.3 Energy-saving use of the heat pump

By purchasing this heat pump you contribute to the stool of our environment. The condition for an energy saving operation is the correct dimensioning of the heat and source-use plant or heating system. cooling system.

It is of great importance for the effectiveness of a heat pump that when heating it keeps the temperature difference between heating water and heat source as low as possible. Therefore, careful dimensioning of the hot-to-heat source and heating system is urgently recommended. A temperature difference of more than one Kelvin (one °C) results in an increase in the power consumption of approx. 2.5%. Note that special loads such as hot water preparation should be taken into account when dimensioning the heating system and also for lower temperatures. Underfloor heating (confusion of surfaces) is optimally suitable for the use of a heat pump due to lower departure temperatures from (30 °C to 40 °C).

During use, contamination of heat exchangers should be avoided as this increases the temperature difference and reduces the power coefficient (COP).

A significant contribution to energy-saving use is also provided by the heat pump controller if it is properly set up. Further information on this is provided in the instructions for use of the heat pump controller.

NL-2

Page 5 of the Dimplex LI 16TER plus user manual — www.dimplex.de NL-3
Page 5 · click to enlarge
Page 5

2 Purpose of use of the heat pump

Cooling

In operating mode .Cooling machines, the condenser and condensor are reversed in their working methods.

The heat water is removed from the coolant via the condenser. The compressor brings the coolant to a higher temperature. The heat is released to the ambient air via the condenser (in heating mode vaporiser).

2.1 Scope

The air-water heat pump can be used in existing or new heating systems.

The heat pump is designed exclusively for heating and cooling of heating water!

The additional heat exchanger can also be used for hot water consumers such as hot water, swimming pool or bath heating.

The heat pump is suitable in heating mode for mono-energy and bivalent operation up to an outdoor temperature of -20 °C.

3 Scope of delivery

In the case of continuous operation, a run-back temperature of hot water above 18 °C shall be maintained to ensure pro-faultless defrosting of the vaporizer.

3.1 Basic device

The heat pump is not designed for the increased heating need during drying after construction. Therefore, the additional heat requirements should be met with special equipment on site. For drying after construction in autumn or winter it is advisable to install an additional heating element (available as accessory).

The basic device is a compact heat pump containing the components below.

The coolant is used as R404A.

In cooling mode, the heat pump for air temperatures of +15 °C is ... - 40 °C.

Dimplex LI 16TER plus — 3.1 Basic device diagram (page 5)
Fig. 3 · 3.1 Basic device

The pump can be used for quiet and dynamic cooling. Minimum water temperature is +7 °C.

2.2 Method of working

Heating

The ventilation system is sucked in by the fan and thereby passed through the vaporiser. The vaporizer cools the air, i.e. It's taking the heat off it. The heat produced is transferred to the working liquid (cooling medium) in the vaporiser.

The heat absorbed by an electrically driven compressor is released to the heating water via pressure increase at a higher temperature level of .pumped .b. and through the condenser (heat exchanger).

The pre-set dehumidifier can also be prepared, even separately, in industrial water.

1. Vaporator (heating mode)

The electrical energy is used to bring the heat of the environment to a higher temperature level. Because the energy extracted from air is transferred to water for heating, this device is also called air-water heat pump.

2. Fan
3. Switchbox
4. Pressostats
5. Condensor (heating mode)

The air-water heat pump consists of the main components vaporiser, fan and expansion valve as well as the loudslow compressor, deheater, condenser and electric control.

6. Compressor

At low ambient temperatures, humidity is at maturity with the vaporizer and inhibits heat transfer. If necessary, the vaporizer shall be automatically thawed through the heat pump. Depending on the weather, steam clouds can be created at the air outlet.

www.dimplex.de NL-3

Page 6 of the Dimplex LI 16TER plus user manual — NL-4
Page 6 · click to enlarge
Page 6

4 Transport

3.2 Switchbox

The switch box is located in the heat pump. After the front plate has been removed and the mounting screw on top right is unscrewed, the switch box can be dissipated.

The control cabinet contains the connection terminals for the power grid, power contacts, soft start unit and heat pump manager.

The pump must be transported on a transport pallet to the place of preparation. The base unit offers the transport option with a hand pallet truck, pushchair or similar. or 3/4" tubes, which are guided through openings in the base plate or into the frame.

3.3 Heat pump regulator

The heat pump manager is a comfortable electronic control and control device. He steers and guards the whole mix-up or. The equipment is also designed to provide a cooling system, depending on the outside temperature, hot water preparation and safety precautions.

Diagram . .
Diagram . .

The external temperature sensor to apply on the spot incl. The control unit shall be provided with the installation equipment.

The operation and use of the heat pump manager is described in the instructions provided.

For the use of transport holes in the frame, it is necessary to remove the lower parts from the front. To this end, two screws are unscrewed on the base and the plates are withdrawn from the top. When applying the plates, they should be pushed upwards with a slight pressure.

When passing through the support tubes in the frame, care must be taken to ensure that no structural parts are damaged.

Diagram . .
Diagram . .
Diagram . .
Diagram . .

Opening of the lid Close the cover

NL-4

Page 7 of the Dimplex LI 16TER plus user manual — www.dimplex.de EN-5
Page 7 · click to enlarge
Page 7

5 Placement

6 Assembly

5.1 General

6.1 General

The device shall be placed in indoor spaces on a smooth, smooth and sunny surface. The frame must be close to the ground in order to ensure appropriate sound insulation. If not, additional noise measures may be necessary. Installation on a bottom-building buffer definitely requires full revolving support. The heat pump shall be so designed that ser- vice can be carried out without problems. This is guaranteed if there is a distance of approx. 1 m for and silks of the heat pump is respected.

The heat pump shall be equipped with the following connections:

. . Departure/reversion of the heating system

. . Departure/reversion of the hot water cycle

6.2 Air connection

P

P

P

The fibre optic air ducts offered as accessories are resistant to moisture and open for diffusion.

The seal cuff is used for sealing the air vents on the heat pump. The air ducts themselves are not screwed directly to the heat pump. Only the seal rubber contact with the heat pump is in ready condition. This ensures, on the one hand, easy assembly and dismantling of the heat pump and, on other, a good separation from construction noise.

P

The apparatus should never be placed in high humidity areas. In the case of air humidity exceeding 50% and outside temperatures below 0 °C, condensate may occur on the heat pump and the air conduction.

When installing the heat pump on a top floor, the load capacity of the ceiling shall be checked and for acoustic reasons vibration decoupling is carefully planned. Placement on a wooden ceiling is unaccep- table.

5.2 Condensate line

The condensate resulting from the use must be removed free of frost. The heat pump should be placed horizontally so that the water can drain properly. The condensate water tube shall have a minimum diameter of 50 mm and be fed free of frost into the drain. Condensation water does not lead di- rectly into sediment ponds and wells, as rising arres- sieve vapours can destroy the vaporizer.

If an air channel other than the one available as accessory is used, then the external and internal dimensions specified in the diagram must be maintained. In addition, appropriate vibration separation and channel insulation shall be observed.

5.3 Noise

In order to prevent noise transmission in the heating system, it is advisable to connect the heat pump with a flexible hose to the heating device. The same applies to the connection of the circuit for sanitary water.

When using the flanged air ducts, a connector shall be attached to the suction and outlet opening of the dams per 4 hexagonal bolts M8x16 on the screw holes provided. In this connection, care must be taken to ensure that both air-conditioning connections come into contact only with the insulation and not with the equipment.

Air ducts used shall be disconnected from the heat pump in sound to prevent transmission of noise on channels.

www.dimplex.de EN-5

. . Supply/exhaust air · .

Page 8 of the Dimplex LI 16TER plus user manual — NL-6
Page 8 · click to enlarge
Page 8
Diagram . .
Diagram . .

Security of frosts

Heat pumps exposed to frost should be emptied by hand (see picture). If the controllers and the heat pump are ready to operate, then the regulator's frost protection works. If the hot pump is shut down or if power failure occurs, the installation shall be emptied. In the case of heat pump systems where power failure cannot be recognized (holiday home), the heating circuit with suitable frost protection shall be used.

Diagram . .
Diagram . .

6.4 Electrical connection

Values in brackets apply to LI 16TER+

The voltage and steering voltage are supplied via conventional pipes (load: 4-arterial, control 3-arterial).

6.3 Heating and hot water connection

The heat pump voltage supply shall be operated from an al-pole cutoff with at least 3 mm contact opening distance (e.g. a main switch of the power supply unit, as well as a 3-pole power switch, with one shut-off for all external cables (exhaust current according to device information).

The connections to the heat pump on the heating side are equipped with a 1 1/4" external wire. When connecting to the heat pump, a key must be used for transitions.

For hot water-sided heat pump connection, the heating system should be flushed down to allow possible dirt, residual insulation material etc. to be removed. If the condenser is blocked by waste and contamination, this may lead to a drop in the heat pump. For installations with a shut-down heating water flow, depending on radiator or radiator Thermostat valves shall be installed on site in a heating bypass behind the heater. This ensures a minimal flow of water through the heat pump and prevents malfunctions.

When connecting, the right-hand field of the load gauge must be guaranteed L1; L2; L3.

The steering voltage shall be protected by 10 A.

For details see the electrical diagrams attached.

After installation of the heating system, it is necessary to fill up and air out and put pressure on.

Minimum water flow rate

The minimum water flow rate of the heat pump shall be guaranteed in each heating mode. This can be done, for example. The system is designed to be capable of being installed by means of a differential pressure-free detector or an overflow valve. The establishment of an overflow valve is explained in the chapter Entrance.

NL-6

Page 9 of the Dimplex LI 16TER plus user manual — www.dimplex.de NL-7
Page 9 · click to enlarge
Page 9

7 Entry into service

Heat source temperatureMax. temperature difference between heating room and - backflow ofto -20 °C-15 °C4 K -14 °C-10 °C5 K -9 °C-5 °C6 K -4 °C0 °C7 K 1 °C5 °C8 K 6 °C10 °C9 K 11 °C15 °C10 K 16 °C20 °C11 K 21 °C25 °C12 K 26 °C30 °C13 K 31 °C35 °C14 K

7.1 General

For commissioning according to the requirements, it must be carried out by a factory-competent service department. Under certain conditions, an extension of the guarantee is associated (if not applicable). Guarantee fee).

The commissioning shall be carried out in the heating mode.

7.2 Preparation

Before entry into service, the following points shall be examined:

. . All connections of the heat pump must be mounted

Malfunctions in a working installation are also displayed on the heat pump controller and can be corrected as described in the instructions for use of the heat exchanger.

(see Chapter 6).

. . In the heating circuit all cranes, which are correct

the water flow could be obstructed, opened.

At outside temperatures below 10 °C and heating water temperatures below 16 °C, the buffer storage vessel shall be heated with the second heat source to a minimum of 25 °C.

. The air intake and exhaust shall be kept free.

. . The direction of rotation of the fan must be in accordance with

with the arrow direction.

The following course shall be respected to achieve the ignition failure-free:

. The settings of the heat pump controller shall be:

have been adapted to the heating system in accordance with its instructions.

1. Close all the heating circuits.
2. Open the flood valve completely.

• The condensation water must be able to run unhindered.

3. Choose the auto mode on the controller.
4. Wait until the buffer storage vessel reaches a temperature of at least 25 °C.

7.3 Operation

5. The closing valves of the heating circuits are then opened slowly again in such a way that the water flow is constantly increased by slow opening of the relevant heat circuit. The temperature of the heating water in the buffer storage vessel shall not fall below 20 °C to allow defrosting of the heat pump at all times.

The heat pump is operated via the heat pump controller. The institutions must be executed in accordance with their manual management.

If the minimum water flow rate is secured by an overflow valve, it must be adjusted to match the heating system. A wrong attitude can lead to fou-tive action and increased energy needs. To properly adjust the flood valve, we recommend to act as follows:

6. When all heating circuits are fully open and a heat water temperature in the buffer storage tank of approx. The minimum flow rate on the overflow valve and heating circulation pump shall be adjusted to 20 °C.

Close all heating circuits, which may be closed even when the installation is working depending on use, so that the water flow in this mode is as unfavourable as possible. These are usually the heating circuits in the rooms on the south and west side. At least one ring of heating must remain geo-pn (e.g. bath).

7. New construction has an increased heat requirement due to the energy needed for drying after construction. This increased heat demand may result in a tight-sized heating system not always reaching the desired room temperature. It is therefore recommended that the second heat source be kept in place during the first heating period. To this end, the limit temperature on the heat pump controller shall be raised to 15 °C.

The overflow valve shall be opened so far that the current heat source temperature results in the maximum temperature difference between the change-off and the decrease-off as specified in the table below. The temperature difference shall be measured as close to the heat pump as possible. In the case of mono-energy installations, the heating element shall be deactivated.

www.dimplex.de NL-7

Page 10 of the Dimplex LI 16TER plus user manual — NL-8
Page 10 · click to enlarge
Page 10

8 Cleaning / maintenance

8.3 Airside cleaning

The air ducts, vaporisers, fans and condensate water drains must be cleaned before the start of the heating season (leaves, twigs etc.). To this end, the heat pump at the front must be opened first on the bottom and then at the top.

8.1 Maintenance

Make sure that no objects are leaned or placed on the device, so as not to damage the paint. The outside parts of the heat pump can be treated with a damp cloth and with clean cleaning products.

The removal and placement of the parts at the front is performed as described in Chapter 4.

In order to prevent any interference by dirt in the heat exchanger of the heat pump, care must be taken to ensure that no dirt can co-exist in the heating system. To protect the vaporizer, a bird grate with at least 80% free diameter in the suction duct is advisable. However, if pollution-related operating failures occur, the installation must be cleaned as described below.

Do not use sharp or hard pre-filled pens for cleaning to protect the vaporiser and condensate water container.

9 Malfunctions / malfunction diagnosis

8.2 Cleaning of heating area

This heat pump is a quality product, which operates under normal conditions of failure and maintenance. If a malfunction occurs, it is displayed on the heat pump manager's display. See the Sto-rings and Disturbance in the instructions for use of the heat pump manager. If you cannot help yourself, please inform the competent service department.

Especially when using steel components, oxygen-resistant products can be de- activated in the hot water cycle. The rust enters the heating system via valves, circulation pumps or plastic pipes. Therefore, a diffusion-tight installation should be observed - especially in the underfloor heating tubes.

10 Decommissioned/removal

Also residues of lubricating and sealing agents can pollute the hot water.

If the pollution is so high that the con-sensor's power in the heat pump is reduced, an installer must clean the installation.

Before disassembling the heat pump, the machine must be voltage-free and all valves closed. Environmentally relevant requirements waste recovery, recycling and disposal of waste and components should be respected according to normal standards. This is particularly true of the professionally dilated coolant and cooling oil.

According to current knowledge, we recommend cleaning with a 5% phosphoric acid or, if more frequent cleansing is required, with a 5 per cent formic acid.

In both cases, the cleaning solution must be at room temperature. It is advisable to rinse out the heat exchanger against normal flow direction.

To prevent acidic cleaning from entering the heat pump circuit, we recommend that the washing machine be connected directly to the departure and return of the condenser.

Afterwards, rinse thoroughly with appropriate neutralising agents to avoid damage caused by any residual clean-up agent.

Acids must be used with caution and the relevant requirements observed.

In case of doubt, the cleaning agent must be consulted with him.

NL-8

Page 11 of the Dimplex LI 16TER plus user manual — www.dimplex.de EN-9
Page 11 · click to enlarge
Page 11

11 Device Information

1 Technical and commercial nameLI 11TER+LI 16TER+ 2 Construction 2.1 ImplementationReversibleReversible 2.2 Degree of protection according to EN 60 529 for compact devices or heating partIP 21IP 21 2.3 Place of establishmentEnterEnter 3 Power data 3.1 Temperature usage limits: Heating water departure/regress1 °C /°Cup to 58 / from 18up to 58 / from 18 Cooling, departure temperature °C+7 to +20+7 to +20 Air (heat) °C-25 tot +35-25 tot +35 Air (cooling) °C+15 tot +40+15 tot +40 3.2 Temperature difference heating water at A7 / W359,75,09,35,0 3.3 Heating power/power coefficient (COP) at A-7 / W35 2 kW / ---7,1 / 2,96,6 / 2,710,6 / 3,010,5 / 2,9 at A-7 / W45 2 kW / ---6,4 / 2,39,9 / 2,5 at A2/ W35 2 kW / ---8,8 / 3,28,8 / 3,112,8 / 3,412,7 / 3,2 at A7/ W35 2 kW / ---11,3 / 3,811,3 / 3,615,1 / 3,814,9 / 3,6 at A7/ W45 2 kW / ---9,6 / 3,114,7 / 3,3 at A10 / W55 2 kW / ---12,2 / 4,112,1 / 3,916,7 / 4,116,6 / 3,9 3.4 Temperature difference in cooling water at A35 / W76,55,06,65,0 3.5 Cooling power/power coefficient (COP) at A27/W7 kW / ---8,8 / 2,88,8 / 2,812,6 / 2,612,5 / 2,6 at A27/W18 kW / ---10,9 / 3,310,8 / 3,216,4 / 2,816,4 / 2,8 at A35/W7 kW / ---7,6 / 2,17,5 / 2,110,7 / 2,010,6 / 2,0 at A35/ W18 kW / ---9,5 / 2,59,5 / 2,514,3 / 2,314,3 / 2,2 3.6 Sound power device / outside dB(A)55 / 6157 / 62 3.7 Sound pressure at 1m distance (inside) dB(A)5052 3.8 Heating water flow at internal pressure differential m3/h / Pa1,0 / 30001,9 / 109001,4 / 45002,6 / 14600 3.9 Cooling water flow rate at internal pressure differential m3/h / Pa1,0 / 30001,3 / 59001,4 / 45001,8 / 7000 3.10 Air flow rate at external static pressure differential m3/h/Pa4200 / 05200 / 0 m3/h / Pa2500 / 254000 / 25 3.11 Cooling agent; total filling weight type / kgR404A / 5,1R404A / 5,7 3.12 Lubricant; total filling quantity type / litrePolyol ester (POE) / 1,5Polyol ester (POE) / 1,9 4 Dimensions, connections and weight 4.1 Dimensions of device H x W x L cm136 x 75 x 88157 x 75 x 88 4.2 Heating inch gear connections1 1/4'" external thread1 1/4'" external thread 4.3 Additional heat exchanger devices (exhaustation of released heat) Inch1 1/4'" external thread1 1/4'" external thread 4.4 Air channel input and exit (inside dimensions min.) L x W cm50 x 5057 x 57 4.5 Weight of transport unit/ units incl. packaging kg232270 5 Electrical connection 5.1 Nominal voltage; security V / A400 / 16400 / 20 5.2 Rated input power2 A2 W35 kW2,742,863,84,0 5.3 Starting current m. softstart system A2325 5.4 Nominal current A2 W35 / cos φ A / ---4,9 / 0,85,16 / 0,86,9 / 0,87,2 / 0,8 6 Compliance with European safety rules33 7 Other features of the version 7.1 De-disposalautomaticautomatic Type of defrostingInverting cycleInverting cycle De-dipper availableyes (with heating)yes (with heating) 7.2 Heating water in apparatus protected against frostyes 4yes 4 7.3 Power levels11 7.4 Internal / External Controllerinternalinternal
1. See diagram on usage limits
2. This data shall represent the size and efficiency of the installation in accordance with EN 255 and EN 14511. Further influence factors, especially defrosting behaviour, bivalentity point and regulation, should be taken into account for economic and energy calculations. For example, this means: A2 / W55: Outdoor air temperature 2 °C and heating water departure temperature 55 °C.
3. see CE declaration of conformity
4. The heating circulation pump and the controller of the heat pump must always be ready for operation.

www.dimplex.de EN-9

Page 12 of the Dimplex LI 16TER plus user manual — NL-10
Page 12 · click to enlarge
Page 12

NL-10

Page 13 of the Dimplex LI 16TER plus user manual — www.dimplex.de A-I
Page 13 · click to enlarge
Page 13

1 Dimensions A-II

1.1 Dimensions LI 11TER+ A-II 1.2 Dimensions LI 16TER+A-III

2 Diagrams A-IV

2.1 Heating mode LI 11TER+ A-IV 2.2 Cooling mode LI11TER+A-V 2.3 Heating Mode LI 16TER+ B-VI 2.4 Refrigeration mode LI 16TERM+ A -VII

3 Electric diagrams A-VIII

3.1 Stiring standard controller A-VIII 3.2 Steering cooling regulator A-IX 3.3 Power A-X 3.4 Connection diagram Standard controller A -XI 3.5 Connector schedule Refrigerator A- XII 3.6 Legend A-III

4 Basic hydraulic diagram A-XIV

4.1 Schematic image A-XIV 4.2 Legend A- XV

5 Declaration of conformity A-XVI

www.dimplex.de A-I

Page 14 of the Dimplex LI 16TER plus user manual — A-II
Page 14 · click to enlarge
Page 14

1 Dimensions

1.1 Dimensions LI 11TER+

Diagram . .
Diagram . .

A-II

Page 15 of the Dimplex LI 16TER plus user manual — www.dimplex.de A-III
Page 15 · click to enlarge
Page 15

1.2 Dimensions LI 16TER+

Diagram . .
Diagram . .

www.dimplex.de A-III

Page 16 of the Dimplex LI 16TER plus user manual — /XFKWLQODDWHPSHUDWXXU .
Page 16 · click to enlarge
Page 16

2 Diagrams

2.1 Heating mode LI 11TER+

9HUZDUPLQJVYHUPRJHQ ŁAŁAŻNAŻNACZNACZOWN:@:DWHUDIYRWEWHPSHUDWXXU ŁHAŻNAŽNACZÓW WŁAŁODNĄCOWNĄCZOWCOWCOWSWŁAŚNACZYNCOWKOWC

9RRUZDDUGHQ

9HUZDUPLQJVZDWHUGHELHW . .

/XFKWLQODDWHPSHUDWXXU .

9HUEUXLN . . LQFO . DDQGHHO .

&RQGHQVRU

/XFKWLQODDWHPSHUDWXXU .

9HUPRJHQFRSIILFLSQW &23 . . LQFO-DQGHHO-SRPSYHUPRHQ

/XFKWLQODDWHPSHUDWXXU .

A-IV

9HUZDUPLQJVZDWHUGHELHW .LQSA.>PÑO-K@

Page 17 of the Dimplex LI 16TER plus user manual — /XFKWLQODDWHPSHUDWXXU .
Page 17 · click to enlarge
Page 17

2.2 Cooling mode LI 11TER+

.RHOYHUPRJHQÍLQИN:@:DWHUDIYRHUWHPSHUDWXXU ŁAWSWŁAWSK

9RRUZDDUGHQ

:DWHUGHELHW. SAME NAME

/XFKWLQODDWHPSHUDWXXU .

9HUEUXLN . . LQFO . DDQGHHO .

&RQGHQVRU

/XFKWLQODDWHPSHUDWXXU .

9HUPRJHQFRSIILFLSQW &23 . . LQFO-DQGHHO-SRPSYHUPRHQ

/XFKWLQODDWHPSHUDWXXU .

www.dimplex.de A-V

9HUZDUPLQJVZDWHUGHELHW .LQSA.>PÑO-K@

Page 18 of the Dimplex LI 16TER plus user manual — /XFKWLQODDWHPSHUDWXXU .
Page 18 · click to enlarge
Page 18

2.3 Heating mode LI 16TER+

9HUZDUPLQJVYHUPRJHQ ŁAŁAŻNAŻNACZNACZOWN:@:DWHUDIYRWEWHPSHUDWXXU ŁHAŻNAŽNACZÓW WŁAŁODNĄCOWNĄCZOWCOWCOWSWŁAŚNACZYNCOWKOWC

9RRUZDDUGHQ

9HUZDUPLQJVZDWHUGHELHW . .

/XFKWLQODDWHPSHUDWXXU .

9HUEUXLN . . LQFO . DDQGHHO .

&RQGHQVRU

/XFKWLQODDWHPSHUDWXXU .

9HUPRJHQFRSIILFLSQW &23 . . LQFO-DQGHHO-SRPSYHUPRHQ

/XFKWLQODDWHPSHUDWXXU .

A-VI

Show 39 more labels / short text on this page
· 9HUZDUPLQJVZDWHUGHELHWLQ>PñK@
Page 19 of the Dimplex LI 16TER plus user manual — /XFKWLQODDWHPSHUDWXXU .
Page 19 · click to enlarge
Page 19

2.4 Cooling mode LI 16TER+

.RHOYHUPRJHQÍLQИN:@:DWHUDIYRHUWHPSHUDWXXU ŁAWSWŁAWSK

9RRUZDDUGHQ

:DWHUGHELHW. SAME NAME

/XFKWLQODDWHPSHUDWXXU .

9HUEUXLN . . LQFO . DDQGHHO .

&RQGHQVRU

/XFKWLQODDWHPSHUDWXXU .

9HUPRJHQFRSIILFLSQW &23 . . LQFO-DQGHHO-SRPSYHUPRHQ

/XFKWLQODDWHPSHUDWXXU .

www.dimplex.de A-VII

Show 38 more labels / short text on this page
· 9HUZDUPLQJVZDWHUGHELHWLQ>PñK@
Page 20 of the Dimplex LI 16TER plus user manual — A-VIII
Page 20 · click to enlarge
Page 20

3 Electrical diagrams

3.1 Stirring standard regulator

Diagram . .
Diagram . .

A-VIII

Page 21 of the Dimplex LI 16TER plus user manual — www.dimplex.de A-IX
Page 21 · click to enlarge
Page 21

3.2 Sturdy cooling regulator

Diagram . .
Diagram . .

www.dimplex.de A-IX

Page 22 of the Dimplex LI 16TER plus user manual — A-X
Page 22 · click to enlarge
Page 22

3.3 Power

Diagram . .
Diagram . .

A-X

Page 23 of the Dimplex LI 16TER plus user manual — www.dimplex.de A-XI
Page 23 · click to enlarge
Page 23

3.4 Standard controller connection scheme

Diagram . .
Diagram . .

www.dimplex.de A-XI

Page 24 of the Dimplex LI 16TER plus user manual — A-XII
Page 24 · click to enlarge
Page 24

3.5 Connection diagram cooling regulator

Diagram . .
Diagram . .

A-XII

Page 25 of the Dimplex LI 16TER plus user manual — www.dimplex.de A-XIII
Page 25 · click to enlarge
Page 25

3.6 Legend

A1 Wirebridge, should be placed when no contactor closure is required A2 Wirebridge must be removed if the second blocking input is used A4 Wirebridge; if an engine protection contact is not needed for the compressor, open wire bridges or contacts mean that there is a blockage or failure B3* Thermostat hot water B4* Thermostate pool water E1 Oil tank heater E3 Pressostat stop defrosting E5 Condensation pressure pressure pressure E9* Electric. hot water heating element E10* 2. Heat source (boiler or leak. (E13* 2. F2 Cooler generator Least-secure for N1 relay outputs at J13 4.0 ATr F3 Latest-security for N1-relaisoutputs at L15 to J18 on N1 and J12 on N2 4.0 Atr F4 Pressostate high pressure F5 Pressure level F7 Thermostat hot gas F23 Thermocontact fan H5 Light fault indication at distance J1...J18 Clamp connector on N1..J15 Clamp regulator J1.J15 Clasp connector on n2 (heat control) K1 Safety switch compressor M1 K2 Safety switch fan M2 K20* Safety switch for E10 K21* Safety switches for E9 K22* Contactor closure electricity company K23* SPR auxiliary relay K28* Application cooling mode M1 Compressor M2 Ventilator M13* Heating pump main circuit M14* Heaters exchange pump 1st heating circuit M15* Heater pump 2nd heat pump M16* Additional circulation pump M18* Hot water pump M19* Swimmer pump * Swiemverbahnpunnelverververkeerkeerkulering m2* Mendschroep

Diagram . .
Diagram . .

Fluid sensor for N5 (maximum 5 sensors)

T1 Safety separation transformer 230/24V AC- 50VA Y1 Fourway switch valve X1 Clamp block power supply 3L/N/PE - 400VAC ~50Hz X2 Clip block steering voltage L/N /PE - 230V ~ 50Hz x3 Clip pad low voltage Abridged information: EVB Entrance seal electricity company SPR Additional locking input MA* Mixing valve open MZ Mixing tap closed * Components should be externally available - - - Can be connected by the customer if required Ready wired

Diagram . .
Diagram . .

www.dimplex.de A-XIII

Page 26 of the Dimplex LI 16TER plus user manual — A-XIV
Page 26 · click to enlarge
Page 26

4 Basic hydraulic diagram

4.1 Schematic image

Diagram . .
Diagram . .

A-XIV

Page 27 of the Dimplex LI 16TER plus user manual — www.dimplex.de A-XV
Page 27 · click to enlarge
Page 27

4.2 Legend

Diagram . .
Diagram . .
Diagram . .
Diagram . .

M13 Heating circulation pump M14 Circulation pump for heating and cooling mode (electronically controlled)

M15 Heating pump 2nd heat circuit (electronically controlled) M18 Hot water circulation pump

N1 Standard controller (with display)

N2 Cooling regulator (without display)

R5 Retractor 2nd heat circuit

www.dimplex.de A-XV

Show 11 more labels / short text on this page
E10 2nd heat source · M19 Swimming pool pump · R1 Outdoor sensor · R2 Retractor (integrated) · R3 Hot water sensor ·R9 Departure sensor · EV Power distribution · KW Cold water · MA Mixing valve open · MZ Mixing tap closed · WW Warm water
Page 28 of the Dimplex LI 16TER plus user manual — A-XVI
Page 28 · click to enlarge
Page 28

5 Declaration of conformity

Dimplex LI 16TER plus — 5 Declaration of conformity diagram (page 28)
Fig. 21 · 5 Declaration of conformity

A-XVI

Page 29 of the Dimplex LI 16TER plus user manual — www.dimplex.de A-XVII
Page 29 · click to enlarge
Page 29

www.dimplex.de A-XVII

Page 30 of the Dimplex LI 16TER plus user manual — A-XVIII
Page 30 · click to enlarge
Page 30

A-XVIII

Page 31 of the Dimplex LI 16TER plus user manual — www.dimplex.de A-XIX
Page 31 · click to enlarge
Page 31

www.dimplex.de A-XIX

Page 32 of the Dimplex LI 16TER plus user manual — 5 Declaration of conformity
Page 32 · click to enlarge
Page 32

Glen Dimplex Deutschland GmbH Geschäftsbereich Dimfix Am Goldenen Feld 18 D-95326 Kulmbach

Errors and changes reserved.

+49 (0) 9221 709 565

www.dimplex.de

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Dimplex LI 16TER plus

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Dimplex LI 16TER plus

Be the first to ask — other owners or our team will answer.

Original document

Dimplex LI 16TER plus manual PDF

32 pages·2.4 MB·Heat Pump·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…