

Please check after opening the packing that all the parts shown in the following parts lists are there. Once you are sure that this is the case, you can start assembly. Please contact us if any components are defective or missing, or if you need any spare parts or replacements in future.
Top-Sports Gilles GmbH Friedrichstr. 55 42551 Velbert Telefon: +49 (0) 20 51 - 6 06 70 Telefax: +49 (0) 20 51 - 6 06 74 4 e-mail: info@christopeit-sport.com www.christopeit-sport.com
This product is created only for private Home sports activity and not allowed to us in a commercial or professional area. Home Sport use class H/C
0 5 10 15 20 25 30 35 40 50 60 70 80 90 100 mm

38 L Pedal axle screw left 1 22+40L 36-1320-07-BT
38 R Pedal axle screw right 1 22+40R 36-1320-08-BT

Illustration Designation Dimensions Quantity Attached to ET number
No. mm illustration No.
39 Axle bushing 16x20x24 4 40 36-9111-12-BT
40 L Pedal support bracket left 1 5L 33-1321-13-WS
40 R Pedal support bracket right 1 5R 33-1321-14-WS
41 Spring washer for ½” 2 38 36-9111-18-BT
42 L Nylon nut left ½” 1 38L 36-9111-19-BT
42 R Nylon nut right ½” 1 38R 36-9111-20-BT
43 Nut cap for ½” 2 42 39-10402
44 Arc washer 8//19 4 45 39-9966-CR
45 Metal bushing 4 6 36-1321-18-BT
46 Hand grip end cap 2 7 36-9111-25-BT
47 Hand grip foam 2 7 36-9111-22-BT
48 Armrest foam grip 2 8 36-1321-10-BT
49 Round end cap 25 2 8 36-9211-21-BT
50 Pulse sensor with cable 2 8 36-1321-11-BT
51 Hex bolt M8x30 2 2+8 39-9906
52 Spring washer for M8 14 16,24,45+51 39-9864-VC
53 Handlebar cover 1 8 36-9110-13-BT
54 Waveform washer 20/28 2 27 36-9217-31-BT
55 Cross screw M4x12 4 9 39-10188
56 Arc washer 8/20 8 16 39-9966-CR
57 Nut cap for M8/13 2 32 36-9214-33-BT
58 Flange nut 1 97 36-8920
59 Arc washer 5//14 1 21 39-10111-VC
60 Tension controller cover 1 2 36-1321-12-BT
61 Metal bushing 14x10x10 4 5 36-1122-12-BT
62 Waveform washer 17//23 2 38 39-9918-22-BT
63 Hex bolt M6x45 2 3+65 39-10410-CR
64 Nylon nut M6 2 63 39-9861
65 Wheel 2 63 36-9825212-BT
66 Washer 4/10 4 55 39-10097
67 Spring washer for M10 4 12 39-9995-CR
68 Washer 22/35 1 22 36-9713-04-BT
69 Bearing cover 2 M22 1 22 36-9713-03-BT
70 Ball bearing 30/45 2 22 36-9713-02-BT
71 Bearing holder 2 1 36-9713-01-BT
72 Hex bolt M6x40 1 1 39-10000
73 Nut M6 4 72+92 39-9861-VZ
74 Nut M22 1 22 36-9713-05-BT
75 Cross screw 3,5x20 2 20 39-9909-SW
76 Bearing cover 1 M23 1 22 36-9713-06-BT
77 Washer 23/38 1 22 36-9713-07-BT
78 Magnet 1 79 36-1122-23-BT
79 Belt wheel 1 22 36-1321-13-BT
80 Belt 1 79+96 36-1321-14-BT
81 Cross screw 4,2x18 5 101 36-9111-38-BT
82 Bolt M6x15 2 86 39-10120-SW
83 Spring washer for M6 2 82 39-9865-SW
84 Washer 6//12 2 82 39-10013-VC
85 C-clip C12 2 87 36-9111-39-BT
86 Magnetic bracket axle 1 87 36-1122-21-BT
87 Magnetic bracket 1 86 33-1321-15-SI
88 Tension spring 1 87 36-9211-27-BT
89 Square cap 1 1 36-1321-15-BT
90 U washer 2 92 36-9713-56-BT
91 Flange nut 1 97 39-9820-SW
92 Eye bolt M6 2 97 39-10000
93 Axle nut 2 97 39-9820
94 Cone spacer 1 97 36-1122-19-BT
95 Bearing 6000Z 2 96 39-9998
96 Flywheel 1 97 33-1321-16-SI
97 Flywheel axle 1 96 36-9211-26-BT

Illustration Designation Dimensions Quantity Attached to ET number
No. mm illustration No.
98 Crank cap 2 101 36-1102-04-BT
99 Screw 4 1+101 39-10190
100 Washer 4 99 39-10510
101 L Chain cover left 1 1+101R 36-1321-01-BT
101 R Chain cover right 1 1+101L 36-1321-02-BT
102 Tool set 1 36-1321-16-BT
103 Assembly and exercise instruction 1 36-1321-17-BT

Remove all the separate parts from the packaging, lay them on the floor and check roughly that all are there on the base of the assembly steps. Please note that a number of parts have been connected directly to the main frame and preassembled. In addition, there are several other individual parts that have been attached to separate units. This will make it easier and quicker for you to assemble the equipment. Assembly time: 35 - 45 min.

1. Attach the front foot (3) with the preassembled end caps (11) to the main frame (1). Do this with the two screws M10x60 (12), curved washers 10//20 (13), spring washers for M10 (67) and cap nuts M10 (14). 2. Attach the rear foot (4) with height adjustable foot caps (15) to the main frame (1). Do this with the two screws M10x60 (12), curved washers 10//20 (13), spring washers for M10 (67) and cap nuts M10 (14). After assembly has been completed, you can compensate for minor irregularities in the floor by turning the eccentric cap (15). The equipment should be set up that the equipment does not move of its own accord during a training session.

1. Place screws M8x16 (16), curved washers 8//20 (56) and spring washers for M8 (52) accessibly beside the front part of the main frame (1). 2. Place the lower end of the support (2) against the holder of main frame (1). Plug the ends of the two computer cables (20) and (18) projecting from (1) and support (2) together. (Note: The computer cable harness (18) projecting from the support (2) must not slide into the tube, as it is required for later steps of installation.) 3. Connect the tension cable of resistance control (17) to the bracket of lower section cable of tension (19) (See figure A1-A4). Before this step of the installation, it is advisable to adjust the resistance setting to the position, at which the cable extends furthest from the sheath. Put the lowest part of cable (17) into the small hook of lower tension cable (19) (figure A1). Pull it (figure A2) until the small hook get in higher position (figure A3) and then insert the cable (17) onto the bracket (19) (figure A4). When joining the tubes, ensure that the cable connection is not trapped. 4. Put one spring washer (52) and one washer (56) on each screw (16). Push the screws (16) through the holes in the support (2), screw into the threaded holes of the main frame (1) but don’t tighten them firmly. (This screw connection point will screw tightly at least in Step 4)

Finally tighten them with spring washer (41) and self locking nut right (42R) firmly. Then put a screw cap ½” (43) onto the nut (42R). (Note: The screws (38L&R) are marked with “L” for left and “R” for right. Please use appropriate nut for left and right screw. On right side the axle screw and nut have to screw clock wise.) 5. Install the left footrest holder left (5L) incl. all additionally required parts on the left hand side of the machine as described in 3. – 4. (Note: The screw direction on left side for axle screw and nut is anti-clock wise.) 6. Now cycle 3-4 movements carefully by hand and tighten the pre-connected screws (16) of step 2 firmly.
1. Put the holder of footrest holder left (5L) at lower end of connecting tube left (6L) and adjust the holes in the tubes so that they are aligned. 2. Push the bolts M8x55 (30) through the holes and tighten the footrest holder left (5L) at connection tube left (6L) with washer 8//16 (31) and nut M8 (32) firmly. (This connection point has to move easily. So please don’t tighten the screw too much.) 3. Install the footrest holder right (5R) incl. all additionally required parts on the right hand side of the machine as described in 1. – 2. 4. Push the screw caps M8-14 (23) onto the screw head of screw (30) and the screw caps M8-13 (57) onto the nuts (32).
1. Push the right footrest (10R) onto the right footrest holder (5R). Adjust the holes in the parts so that they are aligned. 2. Push the screws M10x45 (33) from above through the holes. Push on a washer 10//20 (34) from the opposite side, screw on a nut M10 (35) and tighten firmly. 3. Install the left footrest (10L) on the left footrest holder (5L) as described in 1.– 2. (Note: The right and left footrests can be discerned by the edges of the longitudinal sides of the footrests. The high edges of the footrests (10L+10R) must point inwards (towards the main frame (1).)) 4. Push the screw caps M10 (36) onto the screw head of screw (37) and nuts (35).
1. Place the preassembled unit of the right footrest holder (5R) and connecting tube right (6R) at the right hand side of the main frame (1). (Note: Right is specified as viewed standing on the machine during training.) 2. Put the axle (27) into the center of support (2) and push the wave washer (54) onto the axle (27). 3. Push the connection tube right (6R) onto the axle (27) an put on the screw M8x15 (24) a spring washer for M8 (52) and a washer 8//32 (25) and tighten it firmly. Push the screw cap M8-14 (23) onto the screw head of screw (24). 4. Place the footrest holder right (5R) near to the pedal crank (22). Put onto the axle’s screw right (38R) a wave washer (62) and screw the foot pedal holder (5R) at the pedal crank (22) firmly.



1. Put the handgrip bars (7L+7R) onto the connecting tubes (6L+6R) and adjust the holes in the tubes so that they are aligned. (Note: the handgrip bars must be aligned after assembly so that the upper ends are inclined outwards (away from the support (2)). 2. Push the bolt M8x16 (16) through the holes and tighten the handgrip bars (7) at connection tubes (6) with washers 8/19 (44), and spring washers M8 (52) firmly. 3. Guide the pulse grip (8) through the appropriate holder of support (2) and adjust the holder so that the holes and threats align. Put on each screw M8x30 (51) one spring washer M8 (82) and one washer 8/16 (31) and tighten the pulse grip (8) at the support (2) firmly. 4. Put the pulse cable (50) through the holes at support (9) into top position and attach the grip cover (53) onto pulse grip connection point.

1. Take the computer (9) that has been supplied out of the packaging and insert the batteries (Type “AA”-1.5 V pencells) by watching for the right polarity on the back of the computer (9). (Batteries for the computer are not included in this item. Please buy them at your located market.) 2. Place the computer (9) to support (2) and put the plug of connection cable (18) into the socket from monitor (9) backside and insert the plugs of pulse (50) too. Push the computer (9) to top monitor bracket of front post (2) and secure with screws M4x12 (55) and washer 4//10 (66). (Attention: Ensure that the cable looms are not crunched or pinched during installation. The screws for computer you find on backside of computer)



There are two rollers equipped on the front foot. For moving, you can lift up the rear foot and drive it to where you would like to locate or store it. (Attention: If this item hasn’t got a fixed handlebar, please use carefully the left and right arms for procedure.)
d. Then you can increase the pedaling speed gradually and adjust braking resistance levels to increase the exercise intension. e. Keep always your hands on fixed handle bar or hand grips left and right.
Mount, Use & Dismount Mount: a. Stand beside the item, put the nearest footrest into deepest position and hold the fixed handlebar tightly. b. Put your foot onto the footrest, try to put whole body weight on your foot and simultaneously cross over with your another foot on the other side footrest and place there on the footrest too. c. Now you are in the position to start your training.
Dismount: a. Slow down the pedaling speed until it comes to rest. b. Keep the hands grabbing the fixed handlebar tightly, put one foot cross over the equipment and land on the floor, then land the other one.
This training equipment is a stationary exercise machine used to simulate a combination of biking, stepping and walking without causing excessive pressure to the joints, hence decreasing the risk of impact injuries.
Use: a. Keep your hands in desired position on the fixed handlebar. b. Pedal your exercise item by step your feet on footrests and balance the body weight to left and right side of footrest c. If you like to exercise the upper body too, you can place the hands from fixed handle bar to the left and right handle grips.
Exercise this item offer a non-impact cardiovascular workout that can vary from light to high intensity based on the resistance pre- ference set by the user. It will strengthen your muscles of upper and lower body and increase cardio capacity and maintain fitness of your body also.

Keys: 1. „F“ key: Pressing this key once briefl y makes it possible to change from one function to another, i.e. the respective functions can be selected for which entries can be made using the „E“ key. The currently selected function is indicated by an icon in the respective window.
The supplied computer allows the most convenient training. Every value relevant to training is displayed in a corresponding window. From the beginning of the training session, the required time, the current speed, the approximate calorie consumption, the travelled distance ad the current pulse rate are displayed. All values are counted from zero upwards. The speed is indicated on the upper display. All other values are indicated on the lower display. If you wish to see one value displayed constantly as well as the speed during training, select this with the „F“ key. If you wish to see these values in constant alternation, select the „SCAN“ function. The display then changes from one function to the next at intervals of approx. 6 seconds.
The computer is switched on by briefl y pressing the F- key or simply by beginning training. The computer begins to register and display all values. To stop the computer, just stop training. The computer stops all measurements and retains the last attained values. The last attained values in the functions TIME, CALORIES and KM are stored and training can continue with these values when training is resumed. The computer switches of automatically approx. 4 minutes after training is stopped. All values attained until that time are stored and are displayed again when training is resumed. It is then possible to continue training from these values or to reset all functions to zero using the L- key.


Displays: 1. „SPEED“ (KM/H) display: The current speed is displayed in kilometres per hour. It is not possible to specify a particular value using the „E“ key. The values last attained by this function are not stored. (Limit of the display: 999.9 km/h.)


Replacing the batteries: 1. Open the battery compartment cover and then remove the used Batteries. (If the batteries should leak remove them under increased considering that the battery acid is not into contact with skin come and clean the battery compartment thoroughly.) 2. Insert the new batteries (type (AA) 1.5 V in the correct order and taking into account the polarity in the battery compartment and close the battery cover so that it clicks into place. 3. If the computer does not pick up immediately, the function should Batteries are removed for 10 seconds and re-inserted. 4. The empty batteries properly in accordance with the disposal regulations disposed of and do not give residual waste.
Battery compartment · AA batteries

You must consider the following factors in determining the amount of trai- ning effort required in order to attain tangible physical and health benefits:
1. Intensity: The level of physical exertion in training must exceed the level of normal exertion without reaching the point of breathlessness and / or exhaustion. A suitable guideline for effective training can be taken from the pulse rate. During training this should rise to the region of between 70% to 85% of the maximum pulse rate (see the table and formular for determination and calculation of this). During the first weeks, the pulse rate should remain at the lower end of this region, at around 70% of the maximum pulse rate. In the course of the following weeks and months, the pulse rate should be slowly raised to the upper limit of 85% of the maximum pulse rate. The better the physical condition of the person doing the exercise, the more the level of training should be encreased to remain in the region of between 70% to 85% of the maximum pulse rate. This should be done by lengthening the time for the training and / or encreasing the level of difficulty. If the pulse rate is not shown on the computer display or if for safety reasons you wish to check your pulse rate, which could have been displayed wrongly due to error in use, etc., you can do the following: a. Pulse rate measurement in the conventional way (feeling the pulse at the wrist, for example, and counting the number of beats in one minute). b. Pulse rate measurement with a suitable specialised device (available from dealers specialising in health-related equipment).

2.Frequency Most experts recommend a combination of health-conscious nutrition, which must be determined on the basis of your training goal, and physical training three times a week. A normal adult must train twice a week to maintain his current level of condition. At least three training sessions a week are required to improve one’s condition and reduce one’s weight. Of course the ideal frequency of training is five sessions a week.
3. Planning the training Each training session should consist of three phases: the warm-up phase, the training phase, and the cool-down phase. The body temperature and oxygen intake should be raised slowly in the warm-up phase. This can be done with gymnastic exercises lasting five to ten minutes. Then the actual training (training phase) should begin. The training exertion should be relatively low for the first few minutes and then raised over a period of 15 to 30 minutes such that the pulse rate reaches the region of between 70% to 85% of the maximum pulse rate. In order to support the circulation after the training phase and to prevent aching or strained muscles later, it is necessary to follow the training phase with a cool-down phase. This should be consist of stretching exercises and / or light gymnastic exercises for a period of five to ten minutes. You find further information on the subject warm-up exercises, stretch exercises or general gymnastics exercises in our download area under www.christopeit-sport.com
Calculation formula: Maximum pulse rate = 220 - age (220 minus your age) 90% of the maximum pulse rate = (220 - age) x 0.9 85% of the maximum pulse rate = (220 - age) x 0.85 70% of the maximum pulse rate = (220 - age) x 0.7
Start your warm up by walking on the spot for at least 3 minutes and then perform the following gymnastic exercises to the body for the training phase to prepare accordingly. The exercises do not overdo it and only as far run until a slight drag felt. This position will hold a while.

Reach with your left hand behind your head to the right shoulder and pull with the right hand slightly to the left elbow. After 20sec. switch arm.
Bend forward as far forward as possible and let your legs almost stretched. Show it with your fingers in the direction of toe. 2 x 20sec.
Sit down with one leg stretched out on the floor and bend forward and try to reach the foot with your hands. 2 x 20sec.
Kneel in a wide lunge for- ward and support yourself with your hands on the floor. Press the pelvis down. Change after 20 sec leg.
After the warm-up exercises by some arms and legs shake loose. Don’t finish the exercise phase abruptly, but will cycle leisurely something without resistance from to return to the normal pulse-zone. (Cool down) We re- commend the warm-up exercises at the end of the training be conducted and to end your workout with shaking of the extremities.

Training area in mm (for home trainer and user)
Free area in mm (Training area and security area (rotating 60cm))

Troubleshooting If you cannot solve the problem with the following information, please contact the authorized service center.
Problem Possible Cause Solution
Computer has no value at Display if you press any key.
No Batteries insert or batteries empty
Check the position of batte- ries at battery compartment or replace batteries.
Computer is not counting data and do not switch on after start cycling.
Sensor impulse missing base on not well plugged connection
Check the plug connections at computer and inside of handle- bar support.
Computer is not counting data and do not switch on after start cycling.
Sensor impulse missing base on not correct position of sensor.
Überprüfen Sie das Bremsband auf ordnungsgemäße Einstellung wie in Montage Schritt 5 beschrieben.
Pulse cable is not plugged in.
Check the separately pulse cable is well connected with computer.
Pulse sensors not well connected
Screw out the screw for pulse measurement and check if plugs are well connected and no damage at pulse cable.
Connection of resi- stance not well
Check the resistance connec- tion inside of handlebar support as manual mention.
No pulse value · No pulse value · Resistance don’t change
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Computer has no value at Display if you press any key. | No Batteries insert or batteries empty | Check the position of batte- ries at battery compartment or replace batteries. | p.11 |
| Computer is not counting data and do not switch on after start cycling. | Sensor impulse missing base on not well plugged connection | Check the plug connections at computer and inside of handle- bar support. | p.11 |
| Computer is not counting data and do not switch on after start cycling. | Sensor impulse missing base on not correct position of sensor. | Überprüfen Sie das Bremsband auf ordnungsgemäße Einstellung wie in Montage Schritt 5 beschrieben. | p.11 |
| No pulse value | Pulse cable is not plugged in. | Check the separately pulse cable is well connected with computer. | p.11 |
| No pulse value | Pulse sensors not well connected | Screw out the screw for pulse measurement and check if plugs are well connected and no damage at pulse cable. | p.11 |
| Resistance don’t change | Connection of resi- stance not well | Check the resistance connec- tion inside of handlebar support as manual mention. | p.11 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.