TE-M80-M
User's Manual
START-UP is QUICK and EASY! Simple to use! 15 departments Automatic Tax Calculations Calculator function
GM
Eu · Di

INTRODUCTION
Thank you very much for purchasing this CASIO electronic cash register. START-UP is QUICK and EASY!
Part-1 of this user's manual can help you make a quick start.
Once you have mastered the QUICK START operations, you will undoubtedly want to expand your use of this machine by studying other sections of Part-2.
Original carton / package If for any reason, this product is to be returned to the store where purchased, it must be packed in the original carton/ package.
Power supply Your cash register is designed to operate on standard house- hold current (120V, 220V, 230V or 240V; 50/60Hz). Do not overload the outlet by plugging in too many appliances.
Location Locate the cash register on a flat, stable surface, away from heaters or areas exposed to direct sunlight, humidity or dust.
Cleaning Clean the cash register exterior with a soft cloth which has been moistened with a solution of a mild neutral detergent and water, and wrung out. Be sure that the cloth is thoroughly wrung out to avoid damage to the printer. Never use paint thinner, benzene, or other volatile solvents.

Safety precautions
In this guide various icons are used to highlight safe operation of this product and to prevent injury to the operator and other personnel and also to prevent damage to property and this product. The icons and definitions are given below.
Indicates that there is a risk of severe injury or death if used incorrectly.
Indicates that injury or damage may result if used incorrectly.
To bring attention to risks and possible damage, the following types of icons are used.
The symbol indicates that it includes some symbol for attracting attention (including warning). In this triangle the actual type of precautions to be taken (electric shock, in this case) is indicated.
The symbol indicates a prohibited action. In this symbol the actual type of prohibited actions (disassembly, in this case) will be indicated.
The symbol indicates a restriction. In this symbol the type of actual restriction (removal of the power plug from an outlet, in this case) is indicated.
Should the register malfunction, start to emit smoke or a strange odor, or otherwise behave abnormally, immediately shut down the power and unplug the AC plug from the power outlet. Continued use creates the danger of fire and electric shock.
Do not place containers of liquids near the register and do not allow any foreign matter to get into it. Should water or other foreign matter get into the register, immediately shut down the power and unplug the AC plug from the power outlet. Continued use creates the danger of short circuit, fire and electric shock.
Should you drop the register and damage it, immediately shut down the power and unplug the AC plug from the power outlet. Continued use creates the danger of short circuit, fire and electric shock.
Handling the register

Warning!
Never try to take the register apart or modify it in any way. High-voltage components inside the register create the danger of fire and electric shock.
Power plug and AC outlet
Use only a proper AC electric outlet. Use of an outlet with a different voltage from the rating creates the danger of malfunction, fire, and electric shock. Overloading an electric outlet creates the danger of overheating and fire.
Make sure the power plug is inserted as far as it will go. Loose plugs create the danger of electric shock, overheating, and fire.
Use a dry cloth to periodically wipe off any dust built up on the prongs of the plug. Humidity can cause poor insulation and create the danger of electric shock and fire if dust stays on the prongs.
Do not allow the power cord or plug to become damaged, and never try to modify them in any way. Continued use of a damaged power cord can cause deterioration of the insulation, exposure of internal wiring, and short circuit, which creates the danger of electric shock and fire.
Do not place the register on an unstable or uneven surface. Doing so can cause the register — especially when the drawer is open — to fall, creating the danger of malfunction, fire, and electric shock.
Do not place the register in the following areas.
The above conditions can cause malfunction, which creates the danger of fire.
Do not overlay bend the power cord, do not allow it to be caught between desks or other furniture, and never place heavy objects on top of the power cord. Doing so can cause short circuit or breaking of the power cord, creating the danger of fire and electric shock.
Be sure to grasp the plug when unplugging the power cord from the wall outlet. Pulling on the cord can damage it, break the wiring, or cause short, creating the danger of fire and electric shock.
Never touch the plug while your hands are wet. Doing so creates the danger of electric shock. Pulling on the cord can damage it, break the wiring, or cause short, creating the danger of fire and electric shock.
Never touch the printer head and the platen.


Getting to know your cash register
The position of the mode switch controls the type of operations you can perform on the cash register. The PROGRAM key (marked PGM) that comes with the cash register can be used to select any mode switch setting, while the OPERATOR key (marked OP) can be used to select OFF, REG or CAL only.
PGM RF OFF REG CAL X Z G G OP key G G PGM key
OFF In this position, the power of the cash register is off.
REG (Register) This is the position used for registration of normal transactions.
RF (Refund) This is the position used for registration of refunds.
CAL (Calculator) This is the position used for calculator mode.
PGM (Programming) This is the position used to program the cash register to suit the needs of your store.
X (Read) This is the position used to produce reports of daily sales totals without clearing the totals.
Z (Reset) This is the position used to produce reports of daily sales totals. This setting clears the totals.
Rear customer display Operator display
12#45&78
A
3 Number of repeat display
Anytime you perform “repeat registration” (page 13), the number of repeats appears here. Note that only one digit is displayed for the number of repeats. 4 Numeric display
Entered values (unit prices or quantities) and calculated val- ues (subtotals, totals or change amount due) are displayed here. The capacity of the display is 8 digits. This part of the display can be used to show the current time or date between registration (page 34). 5 Character display
The total or change indicator appears when a subtotal, total or change is obtained. These indicators are also used for depart- ment shift level. 2 Department number display
Anytime you press a department key to register a unit price, the corresponding department number appears here.
In the character programming (P2) mode, it shows the last entered character.
OP key · PGM key · 1 Total/Change indicator

Keyboard

Certain keys have two functions; one for register mode and one for calculator mode. In this manual, we will refer to specific keys as noted below to make the opera- tions as easy to understand as possible:
1 l Feed key 2 ∫Multiplication / Date time key 3 y Clear key 4 g Minus / Error correction key 5 å Department shift key 6 x Percent key 7 n Reference number/No sale key
Normal printing Compressed printing
H | Post receipt key
Numeric keys and 2-zero key 9 " Decimal key 0 G, S, D, F, [ Department keys
jG →Department 6 jS→Department 7…
j[ →Department 10 … jjG →Department 11
… jj[ → Department 15
A . Received on account key B ; Euro / Paidout key C u Charge key D ç Check key E o Subtotal key F p Cash amount tendered key
6 x Percent key 8 ?Z~>, ' Numeric keys and 2-zero key 9 " Decimal key 0 HJKL Arithmetic operation keys A / Memory recall key F p Equal key

Daily Job Flow



To lock/unlock the multipurpose tray
A. Turn the lever (1) clockwise to lock the tray (the indicator becomes red). B. Turn the lever (1) counterclockwise to unlock the tray (the indicator becomes green).
(B)
(1)

1. Initialization and loading memory protection battery
◗To initialize the cash register 1. Set the mode switch to OFF. 2. Plug the power cord of the cash register into an AC outlet. 3. Load the memory protection batteries. 4. Set the mode switch to REG.
◗To load the memory protection batteries 1. Remove the printer cover. 2. Press down on the oval just behind the printer paper inlet, and slide the battery compartment cover toward the back of the cash register. 3. Load 3 new UM-3, R6P (SUM-3) or LR6 (AM-3) type batteries into the compartment. Be sure that the plus (+) and minus (–) ends of each battery are facing in the directions indicated by the illustrations inside the battery compartment (Figure 1). 4. Slide the memory protection battery compartment cover back into place. 5. Replace the printer paper and printer cover.

REPLACE MEMORY PROTECTION BATTERIES AT LEAST ONCE EVERY YEAR.
You can select the default printing language depending on the requirements in your area.
Example: Change the language to Spanish.
Spanish X>>>
A
Select numbers from list A. X>>> {
French C>>>
German V>>>
3. To select date format and monetary mode
You can select t the date format and the monetary mode.
Example: Change the date format to Month/Day/Year, and the monetary mode to Add 0.
Program set code number
Select numbers from lists B and C.
(Figure 1) · Language selections

6 Remove the printer cover by lifting up the back.
5 Remove the journal paper from the take-up reel.
Mode switch to REG


7 Roll the paper onto the take-up reel a few turns. 8 Set the left plate of the take-up reel and place the reel into the register.
6 Press the printer open key and open the platen arm.



7 Remove the core of the paper.

2 Open the platen arm.
9 Press the l key to take up any slack in the paper. 0 Replace the printer cover slowly.


8 Load new paper following the instruc- tions “1. To load journal paper”.
3 Ensuring the paper is being fed from the bottom of the roll, lower the roll into the space behind the printer.
Default printer definition is journal printer. To print receipts, please refer to 1-7-3 on page 24 to switch the printer for receipt or journal.

◗To load receipt paper 1 In case of defining the printer as receipt printer, follow steps 1 through 5 of “To load journal paper”. 2 Pass the leading end of the receipt paper through the paper outlet of the printer cover. 3 Tear off any excess paper.

4 Put the leading end of the paper over the printer.

2 Press the l key until approximately 20cm of the paper is fed from the printer. 3 Cut off the roll paper.
◗To remove receipt paper 1 In case of defining the printer as journal printer, follow steps 6 through 7 of “To remove a journal paper”.

5 Close the platen arm slowly until it locks steadily.

4 Remove the take-up reel from the printer and take off the left plate of the reel.
printer cover · platen arm · ◗Caution

5. Basic programming for QUICK START
Mode switch CAL


6. Basic operation after basic programming
Note:
Whenever an error is generated (E01 displayed), the input figures reset to 0.
6-1 Open the drawer without a sale
n
Z?? G
—— Unit Price/Department No.
Unit price Department 1
—— Subtotal —— Cash amount tendered —— Change amount due
Unit Price $1.00 $2.00
Dept. 1 10
Cash Amount $5.00 tendered
Departments 6 through 10 and 11 through 15 can also be registered in combination with the å and G, S, D, F or [ keys, respectively. The å key should be entered once for department 6 ~ 10, twice for department 11 ~ 15 just before entering unit price manually.
Z?? G
—— Repeat —— Multiplication symbol —— Unit price symbol —— Department No.
Department 1 Unit price
Quantity Unit Price $1.00 $1.35
Dept. 1 2
Z?? G X?? S C?? G
Unit Price $1.00 $2.00 $3.00
Quantity 1 1 1
Dept. 1 2 1
You cannot perform the amount tendered operation using the u key.

Printout Operation
6-5 Split cash/ charge sales
X?? G C?? S V?? G
Unit Price $2.00 $3.00 $4.00
Quantity 1 1 1
Dept. 1 2 1
Cash Amount $5.00 tendered
6-6 Corrections Corrections can be made while you are registering the item (before you press a department key), or after it has already been registered into the memory (by pressing a department key).
y key clears the last item entered.
Wrong entry Clears the last item entered.
Correct entry Registered department 1
y
Clears the last item entered.
X?? S
ZB? y
Wrong entry Clears the last item entered.
Correct entry Registered department 3

Operation Printout
g key cancels the last registered item. 6-6-2 After you pressed a department key
Cancels the last item registered.
Registered department 1 Correct entry
g
Cancels the last item registered.
Correct entry Registered department 2

6-7 Currency exchange
6-7-1 Registering with currency exchange
Display Operation
Unit Price 2.00
Dept. 1
Cash Amount Euro 15.00 Tendered
Rate 1Euro = 0.5 Fr
Main currency Local (Fr)
Pressing ; before subtotal converts the subtotal amount into the Euro.
Printout of ST Both currencies
;
Pressing ; after amount tendered converts the amount into the Euro. *1
!50
Press p to finalize the transaction. The change amount in the main currency is shown on the display. *2
You can switch the currency of change amount repeatedly by pressing the p key.
*1 If the payment is the same as the subtotal amount, you can omit this operation. Press p key directly after the subtotal. *2 If the payment is less than the subtotal amount, the cash register specifies it as a partial payment and shows the balance in the main currency on the display.
—— Subtotal in the main currency —— Subtotal after conversion
—— Payment in the Euro —— Payment after conversion —— Change in the main currency —— Change in the sub currency
Mode switch REG · Quantity 3

7. Daily management report
This section tells you the procedures to use to produce reports of the transaction data stored in the cash register's memory.
∫
—— Mode/Date/Time —— /Consecutive No.
—— Gross sales No. of Items —— Gross sales amount —— Net sales No. of customers —— Net sales amount —— Cash total in drawer —— Charge total in drawer —— Check total in drawer
—— Mode/Date/Time —— Consecutive No.
0000 DAILY Z 0012
—— Report code/Title/Reset counter*
—— Dept. name/No. of items —— Amount
—— Gross sales No. of items —— Gross sales amount —— Net sales No. of customers —— Net sales amount —— Cash in drawer —— Charge in drawer —— Check in drawer —— Taxable amount 1 —— Tax amount 1 —— Refund mode count —— Refund mode total —— CAL mode count
—— Cash sales count —— Cash sales amount —— Charge sales count —— Charge sales amount —— Check sales count —— Check sales amount —— Received on account total —— Paidout total —— Reduction amount —— Premium/Discount amount —— Error correct count —— No sale count
—— Non resettable ground total *
* X (Read) report has the same contents except * marked items.

7-2-2 Periodic read/reset report
Printout Operation
Mode switch to or
—— Mode/Date/Time —— Consecutive No.
—— Report code/Title/Reset counter
GROSS TOTAL QT 67
—— Gross sales No. of items —— Gross sales amount —— Net sales No. of customers —— Net sales amount

1. Various programming
Unit Price $1.00 $2.20 $11.00
Dept. 1 2 13
(For Dept. 1)
(For Dept. 2)
(For Dept .13)
Z o
Discount Rate 2.5%
Tax status for the departments 1~4 are initialized as nontaxable.
.G
Status Taxable 1 Taxable 2
Depts. 1 2
Taxable status 1 For Dept. 1
Taxable status 2 For Dept. 2
Taxable status 1 .
Taxable status 2 ;
Taxable status 1 and 2 .;
Mode switch · Selections · Nontaxable status n

Selections A B C 1 0 4 1
Depts.
7 0 5 1
For Dept. 1
Single item sale department
Maximum No. of digits to be 4
For Dept. 7
Single item sale department
Maximum No. of digits to be 5
A
Minus department Z
No limitation for manually entered price. ?
Maximum number of digits for manually entered price
(1 ~ 7 digits). Z ~ M
To prohibit manual price entries. < or >
Normal sale (not a single-item sale) department. ?
Set as a single-item sale department. Z
1-5 Status for percent key
The percent key is initialized as nontaxable.
Change percent key registra- tion as a taxable status 1.
(For percent key) Taxable status 1
Taxable status 1 .
Taxable status 2 ;
Taxable status 1 and 2 .;

C o
ZZ x
Round up Premiums (%+)
Rounding of results produced by percent key operation.
Round off (1.544=1.54; 1.545=1.55) ?
Round up (1.544=1.55; 1.545=1.55) Z
Cut off (1.544=1.54; 1.545=1.54) X
Program percent key to register discounts (%–). ?
Program percent key to register premiums (%+). Z
The minus key is initialized as nontaxable.
Change minus key registrations taxable status 1.
Minus key Taxable status 1
Taxable status 1 .
Taxable status 2 ;
Taxable status 1 and status 2 .;

C o
?NXX o
Program code No.
Select a number from list A
Select a number from list B
Select a number from list C
Maintain key buffer during receipt issue in REG mode.
Reset the transaction number to zero whenever a daily reset report is issued.
Allow credit balance registration.
Limit the last 2 digits of cash amount tendered to 00, 25, 50 and 75 when Danish rounding is specified for subtotal and total amount.
Allow partial cash amount tendered.
Allow partial check amount tendered.
C Use the ' key on a numeric keyboard. ?
Use the ' key as a 000 key. Z

C o
?BXX o
Program code No.
Select a number from list A
Select a number from list C Select a number from list B
Select a number from list D
Use the printer to print receipts. Z
Print zero-total item on the daily/periodic read/reset reports.
Print receipt by single/double height characters.
Print total line at finalization.
BY DOUBLE HEIGHT
B
BY SINGLE HEIGHT
BY DOUBLE HEIGHT
Print RF mode count/amount on the daily read/reset report.
Print the grand sales total on the daily reset report.
Print the time on the receipt and journal.
Print the consecutive number on the receipt/journal.
Print the subtotal on the receipt/journal when the subtotal key is pressed.
Skip item print on journal.

The printer is initialized as journal.
To print a receipt
Z u
Use the printer to print a journal. ?
Use the printer to print receipts. Z
Mode switch CAL · Print receipt · Selections

C o
?ZXB o
Program set code No. for tax rate 1*1
Enter tax rate A
Select numbers from list B
Select number from list C
Select number from list D
(To end the setting) *1 Program set code No. for tax rate 2 is ?XXB.
The tax rate within the range of 0.0001 ~ 99.9999%.
Use " key for decimal point.
Cut off to 2 decimal places. ??
(1.544=1.54, 1.545=1.54)
Round off to 2 decimal places. B?
(1.544=1.54, 1.545=1.55)
Round up to 2 decimal places. >?
(1.544=1.55, 1.545=1.55)
Special rounding specifications for subtotal and total amounts
Special rounding 1 Z
0 ~ 2 ➝ 0, 3 ~ 7 ➝ 5, 8 ~ 9 ➝ 10
Special rounding 2 X
0 ~ 4 ➝ 0, 5 ~ 9 ➝ 10
Danish rounding C (set the amount tender restriction on page 22 also) 00~ 12 ➝ 0, 13 ~ 37 ➝ 25, 38 ~ 62 ➝ 50,
63 ~ 87 ➝ 75, 88 ~ 100 ➝ 100
1.80=1.75, 1.99=2.00
00~ 24 ➝ 0, 25 ~ 74 ➝ 50, 75 ~ 99 ➝ 100
Australian rounding (only for tax rate 1) M
0 ~ 2 ➝ 0, 3 ~ 7 ➝ 5, 8 ~ 9 ➝ 10
Tax system specifications for subtotal and total amounts
No specifications. ?
Specifies add-on rate tax. X
Specifies add-in rate tax (VAT). C

C o
?CXN o
Program set code No.
Select number from list A
Select number from list B
Print tax total line (only for Australia).
Print tax symbol (only for Australia).
Print taxable amount.
Print taxable amount and tax amount for Add-in.

In the PGM 2 mode, the keyboard becomes character setting keyboard illustrated below after specifying a department, or a message.

1Double size key Use this key to specify the next character to a double sized character. You must press this key before each double sized charac- ter.
2Alphabet keys Use these keys to input characters. Refer to the next page to enter characters.
3Right arrow key Use this key to input the character located on the same alphabet key. This key is also used for inputting a space.
4Delete key Use this key to delete character just entered.
5Department keys Use this key to specify department. 6Department shift key Use this key to shift department.
7Program end key (k key) Use this key to terminate character programming.
8Character program key (p key) Use this key to program the department / message characters just entered before.

Name DAIRY HBA up to 8 (4 double sized) characters
D A I R Y → refer to 1-10-4
Mode switch CAL

X k
Line (1 ~ 5) 2
Message THANK YOU up to 24 (12 double sized) characters
Line No.
T H A N K fix “K” space
Y O U → refer to 1-10-4

1-10-4 Alphabetical order Characters are assigned to each numeric key. You can enter “A” by pressing < once, “B” twice, “C” three times … The following tables indicate character assignment and the depression numbers of the key to enter the appropriate character.
: A →B →C →a →b →c →8 → A .01 B .02 C .03 a .04 b .05 c .06 8 .07
a, b, c, 8, …
< key →Ä →Å →Æ →Á →Â →À →Ã → A .08 A .09 A .10 A .11 A .12 A .13 A .14
→Ç →â →ä →à →å →æ →á → C .15 a .16 a .17 a .18 a .19 a .20 a .21
→ã →ç →returns to the beginning a .22 c .23
: D →E →F →d →e →f →9 → D .01 E .02 F .03 d .04 e .05 f .06 9 .07
> key → →É →Ê →Ë →È → →é → D .08 E .09 E .10 E .11 E .12 d .13 e .14
→ê →ë →è →ƒ →returns to the beginning e .15 e .16 e .17 f .18
: G →H →I →g →h →i →4 → G .01 H .02 I .03 g .04 h .05 i .06 4 .07
g, h, i, 4, …
V key →Í →Î →Ï →Ì →ï →î →ì → I .08 I .09 I .10 I .11 I .12 i.13 i .14
→í →ı →returns to the beginning i .15 i .16
: J →K →L →j →k →l →5 → J .01 K .02 L .03 j .04 k .05 l .06 5 .07
j, k, l, 5,
B key → returns to the beginning
M, N, O, m, n, o,
: M →N →O →m →n →o →6 → M .01 N .02 O .03 m .04 n .05 o .06 6 .07
N key →Ñ →Ö →Ø →Ó →Ô →Ò →Õ → N .08 O .09 O .10 O .11 O .12 O .13 O .14
→ñ →ô →ö →ò →ø →ó →õ → n .15 o .16 o .17 o .18 o o .19 o .20 o .21

: P →Q →R →S →p →q →r → P .01 Q .02 R .03 S .04 p .05 q .06 r .07
Z key →s →1 → → →ß →returns to the beginning s .08 1 .09 P .10 p .11 s .12
: T →U →V →t →u →v →2 → T .01 U .02 V .03 t .04 u .05 v .06 2 .07
X key →Ü →Ú →Û →Ù →ü →û →ù → U .08 U .09 U .10 U .11 u .12 u .13 u .14
→ú →µ →returns to the beginning u .15 u .16
: W →X →Y →Z →w →x →y → W .01 X .02 Y .03 Z .04 w .05 x .06 y .07
w, x, y, z,
3, …
C key →z →3 → → →ÿ →returns to the beginning z .08 3 .09 Y .10 y .11 y .12
: 7 →@ →- →/ →: →! →? → 7 .01 @ .02 - .03 / .04 : .05 ! .06 ? .07
M key →~ →( →) →* →# →+ →, → ~ .08 ( .09 ) .10 * .11 # .12 + .13 , .14
→^ →; →< →= →> →$ →¥ → ^ .15 ; .16 < .17 = .18 > .19 $ .20 ¥ .21
→% →& →[ →] →' →{ →| → % .22 & .23 [ .24 ] .25 ' .26 { .27 | .28
→£ →√ →¿ →¡ →™ →§ →space → £ .36 ™.37 ¿ .38 ¡ .39 ¶ .40 § .41 .42
Cf.
Indication of the above character
Printing character

p
DEPT01 T1 @1•00 000 DEPT02 @10.00 000 DEPT15 @5.00 000
—— Dept. name/Tax status/Unit price —— Normal dept./Digit limit/Single item
—— Minus/Tax status —— Percent/Tax status/Rate —— Fraction/Key attribution —— Euro conversion rate
0122 22 0522 1020 0622 0000 1022 0 0326 202 2422 22 0125 0.0000 % 5003 0000 0225 5.2500 % 5003 0000
—— Date, Add mode control (fixed) —— Print control —— General control —— Calculation control —— Tax control —— Euro program —— Tax table 1
—— Tax table 2
TAXABLE SUPPLY
—— Read Symbol · Mode switch CAL · —— Receipt message

2-1 Registration using preset price for de- partments.
Unit Price $1.00 $2.20 $11.00
Quantity 1 2 4
Depts. 1 2 3
$50.00
2-2 Single-Item Sales
Unit Price $0.50
Dept. 1
Status Normal Single item sale
Unit Price $1.00 $0.50
o p
Dept. 2 1
Single-item sale cannot be finalized if an item is registered previously.
CB?? F
Unit Price $35.00
Dept. 4

C??? S XB?? D
Unit Price $30.00 $25.00
Depts. 2 3
Cash amount $20.00 tendered
Check $35.00
You can issue a post receipt after finalizing a transaction by pressing |.
Unit price $1.00 $2.00
Depts. 1 2
Cash amount tendered $5.00
You can issue only one post receipt per transaction.
(Receipt is not issued.)
(Receipt is issued.)
If the transaction contains more than 20 lines (including receipt header), then the total formatted post receipt is issued.
(Total formatted post receipt)
Mode switch 2-6 Refund
Z RF
Printout Operation
Z?? S X?? D
Unit Price $1.00 $2.00
Dept. 2 3
After you finish RF mode operation, be sure to return the mode switch to the REG (register) setting.

2-7 Other registrations
Display Operation
2-7-1 Reading the time and date
∫
13-5#
08-01-04
∫
~00
y
2-7-2 Paidout from cash in drawer
PD •10.00 —— Paid out amount
2-7-3 Cash received on account
N?? .
—— Received on account amount
Printout Operation
2-7-4 Registering identification numbers
B? G ZXCV BNM< n
A reference number or ID number of up to 8 digits can be registered prior to any transaction.
Printout Operation
Example: Amount due reduced by $0.50. Z?? G X?? F
p
Mode switch · Hour/Minute · Day/Month/Year

Z?? G
—— Premium rate —— Premium amount
—— Subtotal —— Premium rate —— Premium amount
—— Discount rate —— Discount amount
—— Subtotal —— Discount rate —— Discount amount
2-8 About the daylight saving time
It is possible to set the internal clock forward/backward by 1~9 hour(s) for the daylight saving time.
12-3$
12-3$
∫
13-3$
Set forward by 1 hour.
~00
∫
12-3$
12-3$
12-3$
11-3$
∫
Set backward by 1 hour.
y
*Put X~>, in case of set the clock by 2~9 hours.

1. Calculator Mode
While registering at REG mode, you can switch to CAL mode and then return to REG mode to resume the registration.
1-1 Calculation examples
t B q Z t
(Cancels item entered.)
5 + 3 – 2 =
(23 – 56) × 78 =
ZB?? e ZX x
1-2 Memory recall
Recalls the current amount onto the display.
Example: Divide the current subtotal $30.00 at REG mode by 3 (to divide the bill between 3 people).
On REG mode Recalls the current result by pressing p key at CAL mode on the display.
Z REG
/ p / p / p
Example: Recall the current result at CAL mode during registration, and register the cash amount due for each person.

1-3 Setting for calculator operation
C o
Z?XX o
Program code No.
Select a number from list A.
Open drawer whenever p is pressed.*
Open drawer whenever n is pressed.
Print No. of Equal key operations on General Control X and Z reports.
* Drawer does not open during registration procedures even if you press p by turning the mode switch to CAL position.

1. Troubleshooting
Symptom/Problem Most common causes Solutions
1 E01 appears on the display.
Changing modes without completing transaction.
Return key to where it stops buzzing and press p.
2 E10 appears on the display.
Printer is not closed steadily. No paper
Close the printer steadily. Replace new paper roll.
If there is enough paper installed, open the printer and set the platen arm again.
3 No date or time on receipt. Paper is not advancing enough.
Printer is programmed as a journal.
Program printer to print receipts.
4 Key won’t turn to Z, X, PGM and RF modes.
Using OP key.
Use the PGM key.
5 Drawer opens up after ringing up only one time.
Department is programmed as a single item dept.
Program the dept. as a normal dept.
6 Not clearing totals at end of day after taking report.
Using X mode to take out reports.
Use Z mode to take out reports.
Put in new batteries.
7 Programming is lost whenever register is unplugged or there is a power outage.
Bad or no batteries.
8 Register is inoperative. Can’t get money out of drawer.
No power.
Pull lever underneath register at rear.
In case of power failure or the machine is in malfunction, the cash drawer does not open automati- cally. Even in these cases, you can open the cash drawer by pulling drawer release lever (see below).

Input method:
Entry: 10-key system; Buffer memory 16 keys (2-key roll over) Display (Digitron): Amount 8 digits (zero suppression); Department No.; No. of repeats; TOTAL; CHANGE
Printer:
Receipt: 24 digits (or journal) Automatic paper roll winding (journal) Paper roll: 58 mm × 80 mm ∅ (Max.)
Calculations:
Entry 8 digits; Registration 7 digits; Total 8 digits Calculator function:
8 digits; Arithmetic calculations; Percent calculations
Memory protection batteries:
The effective service life of the memory protection batteries (3 UM-3, R6P (SUM-3) or LR6 (AM-3) type batteries) is approximately one year from installation into the machine. Power source/Power consumption:
See the rating plate. Operating temperature: 0°C to 40°C (32°F to 104°F) Humidity: 10 to 90% Dimensions/Weight: 330 mm (W)× 360 mm (D)× 197 mm (H) with S drawer 4 kg with S drawer 410 mm (W)× 450 mm (D)× 240 mm (H) with M drawer 9 kg with M drawer
Specifications and design are subject to change without notice.
The main plug on this equipment must be used to disconnect mains power. Please ensure that the socket outlet is installed near the equipment and shall be easily accessible.
Casio Electronics Co., Ltd. Unit 6, 1000 North Circular Road London NW2 7JD, U.K.
Please keep all information for future reference.

CASIO COMPUTER CO., LTD. 6-2, Hon-machi 1-chome Shibuya-ku, Tokyo 151-8543, Japan
MO0306-A Printed in Indonesia
Printed on recycled paper.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| E01 appears on the display. | Changing modes without completing transaction. | Return key to where it stops buzzing and press p. | p.38 |
| E10 appears on the display. | Printer is not closed steadily. No paper | Close the printer steadily. Replace new paper roll. set the platen arm again. | p.38 |
| E10 appears on the display. | If there is enough paper installed, open the printer and | set the platen arm again. | p.38 |
| No date or time on receipt. Paper is not advancing enough. | Printer is programmed as a journal. | Program printer to print receipts. | p.38 |
| Key won’t turn to Z, X, PGM and RF modes. | Using OP key. | Use the PGM key. | p.38 |
| Drawer opens up after ringing up only one time. | Department is programmed as a single item dept. | Program the dept. as a normal dept. | p.38 |
| Not clearing totals at end of day after taking report. | Using X mode to take out reports. | Use Z mode to take out reports. | p.38 |
| Programming is lost whenever register is unplugged or there is a power outage. | Bad or no batteries. | Put in new batteries. | p.38 |
| Register is inoperative. Can’t get money out of drawer. | No power. | Pull lever underneath register at rear. | p.38 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.